Competence for Safety. ATEX Category 3 Description. Example of a zone division for combustible fluids (gases) and combustible dust

Size: px
Start display at page:

Download "Competence for Safety. ATEX Category 3 Description. Example of a zone division for combustible fluids (gases) and combustible dust"

Transcription

1 Competence for Safety Within the scope of the creation of the explosion protection document (mandatory for the operator according to ATEX 137), production locations must be divided into zones depending on their ignition hazard potential. ATEX Category 3 Description Category 3 equipment can be used in zones in which potentially explosive atmospheres do not occur during normal operation or only for a short period of time like zone 2 for gases and zone 22 for dusts. Zone 22 is divided into two kinds of dust: Conductive dust: use of category 2 equipment Non-conductive dust: use of category 3 equipment It is also permitted to use equipment with a higher equipment category rating. However, the procurement of this kind of equipment is more expensive, but it does increase safety and provides you with more flexibility if you frequently change the zone divisions during operation. Typical zone 2 areas are areas that encompass zone 0 or 1. Typical zone 22 areas are areas in the vicinity of equipment that contain dust which can escape from leaks and form dust deposits in hazardous quantities. The tank stands in the open, is filled and drained regularly and has a pressure equalization opening. The flashpoint of the combustible liquid is near the annual average temperature therefore, it is has been accepted that there is a longterm potentially explosive atmosphere in the tank interior: Zone 0. Vapors will occasionally vent out of the pressure equalization opening and form a potentially explosive mixture therefore, the area around the opening: Zone 1. Vapors can flow downwards on the tank wall under unfavorable atmospheric conditions therefore, the area around the tank: Zone 2 A dusty, combustible product is ground and filled in the mill. The initial product is manually filled into a holding tank. Because this occasionally causes a potentially explosive dust/air mixture to form: Zone 21 The area around the holding tank has dust deposits that are not likely to be dispersed, but if they are, for a short period only: Zone 22 Liquid surface Example of a zone division for combustible fluids (gases) and combustible dust The mill has a constant dust cloud even when cleaning the filter hoses: Zone 20 The ground product is continuously discharged therefore, in the discharge tank: Zone 20 Dust deposits are in the discharge area due to leaks: Zone 22

2 The size of the respective area (zones) depends on several factors, e.g. amount of dust or availability of natural ventilation, frequency of filling and drainage, etc. The different zones are designated with different shadings/ dottings in the corresponding diagrams or drawings in the explosion protection document. The manufacturer submits a Declaration of Conformity. This is provided to the customer with the operating instructions, e.g. a Sartorius scale for zone 2 and/or 22 (equipment category 3). Sartorius also provides the customer with installation and safety instructions for the category 3 equipment. Declaration of Conformity from the Manufacturer Contrary to equipment category 1 and 2, no type examination test is required for equipment category 3. Instead, the manufacturer can evaluate for himself the requirements of the equipment directive (ATEX 95 - binding for the manufacturer) for the corresponding type of ignition protection using corresponding technical knowledge. Typical Type of Ignition Protection for Category 3 Equipment: "n" The n type of ignition protection has several implementation types that are designated with a second letter. You will find these types of ignition protection in Sartorius products for zone 2, for example: na: nc: nr: nl: non-sparking non-incendive components (circuits), also hermeti cally sealed or encapsulated device protected by a restricted breathing enclosure energy limited SARTORIUS AG Göttingen (Germany) Weender Landstr Typ: IU / Option Y2 IF / Option Y2 Modell Ser.-Nr. IFS4-3000WR-NCE II 3 GD EEx na II T6 T80 C IP65/67 U max = 15 V DC Example of marking for Sartorius flat-bed and pallet scales designed for use in zones 2 and 22 In Sartorius equipment, "protected by a restricted breathing enclosure" (we refer to this as non-breathing enclosure ) is implemented for zone 22. The following pages provide an overview of Sartorius products for zones 2 and 22 For more information about the Sartorius product range available for other potentially explosive atmospheres, see our Sartorius EX products overview flyer. Please request a copy. FAX REPLY +49 (0) I would like to have a sales consultant phone me. Name Sartorius AG Weender Landstrasse Goettingen Please send me your written information on the following: A brief overview of Sartorius EX weighing equipment Explosion protection document Dust explosion protection EX consultation services about our products and those of other manufacturers compatible with ours Risk assessment for non-electrical equipment Company Street Address City Country ZIP Phone Fax

3 Weighing equipment for use in zone 2 (gases) Zone 2 (acc. to CENELEC, IEC) Division of hazardous areas according to the Directive 1999/92/EC, ATEX 137: A place in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapor or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only. This zone requires equipment group 3G (1G or 2G is also possible). Combics series: CIS. indicator + Option Y2 With built-in A/D converter for analog platforms or load cells up to 32 t Type of ignition protection: restricted breathing enclosure (non-breathing), ATEX: II 3GD EEx nr II T6 T80 C In 4 versions featuring different levels of applications Stainless steel housing with cable glands 3 interface ports standard Can be networked with up to 8 client devices Combics series: CAPx platforms + Option Y2 Weighing capacity from 0.1 g to 3 t, also Type of ignition protection: non-sparking, ATEX: II 3 GD EEx na II T6 T80 C Low-profile, stainless steel design Other materials optional for the load plate, underframe and lift-deck system Combics series: CW.Sx complete scale + Option Y2 Weighing capacity from 0.1 g to 3 t, also Type of ignition protection: non-sparking, restricted breathing enclosure, ATEX: II 3 GD EEx nar II T6 T80 C 4 display unit versions featuring different levels of applications Stainless steel material, 11 different sizes Customized equipment and features (interfaces, materials ) optionally available Factory series: IS digital precision platforms Weighing capacity from 0.1 g to 300 kg, also Type of ignition protection (150, 300 kg): restricted breathing enclosure, ATEX: II 3 GD EEx nr II T6 T80 C Type of ignition protection (16 64 kg): non-sparking, ATEX: II 3 GD EEx na II T4 T80 C IP65 (without built-in, motorized calibration weight) RS-232C data interface standard (other optional data interfaces can be installed) Can be networked with up to 8 client devices Modular series: isi terminal indicator Terminal (or with built-in A/D converter as an indicator) 3 platforms max. can be connected Type of ignition protection: energy limited, ATEX: II 3 G EEx nl IIB T5 With numerous applications programs that can be combined with one another Wide variety of interfaces IFS and IFP flat-bed scales with Option Y2 Weighing capacity 0.1 g to 3 t, also IFS material: stainless steel; IFP material: painted steel; other materials optional Type of ignition protection: nonsparking, ATEX: II 3GD EEx na II T6 T80 C High-grade material and outstanding workmanship design ideal for use in the pharmaceutical industry Easy to clean thanks to load plate lifting mechanism Exceptionally low-profile design for especially easy loading High protection rating: IP68 IUS and IUG pallet scales with Option Y2 Weighing capacity from 0.1 g to 1.5 t, also ( e e ; class l) IUS material: stainless steel; IUG material: galvanized steel Type of ignition protection: nonsparking, ATEX: II 3GD EEx na II T6 T80 C High protection rating: IP68 Quality series: QA and QC compact scales and QCT indicator Weighing capacity from 0.1 g to 150 kg, also Type of ignition protection: non-sparking, non-incendive circuits, ATEX: II 3 G Ex nac IIB T4 Combinable application programs and product memory Numeric keypad Type of protection rating: IP65 Factory series: compact FD Weighing capacity from 1 g to 300 kg, also factory-verified for legal metrology Type of ignition protection: restricted breathing enclosure, ATEX: II 3 G EEx nr II T6 With monolithic weigh cell (metrological advantages; built-in, motorized calibration weight, advantageous for use in quality systems) RS-232C data interface standard Practical application programs Economy EA, EB series, PMA Economy (aluminum die-cast): weighing capacity 0.1 g to 150 kg, also, depending on the model Type of ignition protection: nonsparking, non-incendive circuits, ATEX: II 3 G Ex nac IIB T4 RS-232C data interface standard (optional RS-422 data interface) Backlit LCD PR17 transmitters Modern field instrumentation for tank and hopper scales Type of ignition protection (PR171x digital transmitters): non-sparking, ATEX: II 3 G Ex na II T4 Type of ignition protection (PR1720 fieldbus transmitters): non-sparking, ATEX: II 3 GD EEx na II T4 T100 C IP65 Intrinsically safe load cell power supply With or without weight display Smart calibration via load cell data Field housing: IP65 or 19 Euroformat X5 controllers Pre-programmed applications Type of ignition protection: non-sparking, hermetically sealed device, energy limited, ATEX: II 3 G Ex nacl II T4 Easy menu-guided operation, integrated PLC function Option cards already installed Load cells Wide capacity range up to 300 t Various designs (tension and bending beam load cells, compression load cells, PanCake level cells, specialty load cells) 15 Zone 2 Explosive Gases Category ll 3 G

4 Combics series Flat-bed scale Factory series IS digital precision platforms Pallet scale X5 controller Configurations with Combics and Option Y2 in zone 2 Combics platform + Option Y2 Flat-bed scale + Option Y2 Combics indicator + Option Y2 Pallet scale + Option Y2 IS precision platform ( kg) + Option Y2 Combinations with precision platforms in zone 2 Combics platform IS precision platform ( kg) X5 controller Combics platform IS precision platform ( kg) isi terminal Alternative configuration versions 16

5 Modular series isi indicator Economy* series E * called the Express series in North America Quality series Q Configurations with indicator and analog platforms in zone 2 Combics platform + Option Y2 Flat-bed scale + Option Y2 isi terminal with A/D converter Pallet scale + Option Y2 Configurations with complete scales QC indicator in zone 2 Load cells, e.g., PR62 Combics platform, CAP + Option Y2 QCT indicator Factory-FD Economy Quality Configuration with load cells in zone 2 X5 controller Load cells, e.g., PR62 PR17.. transmitter PLC or Alternative configuration versions 17

6 Weighing equipment for use in zone 22 (dusts) Zone 22 (acc. to CENELEC, IEC) Division of hazardous areas according to the Directive 1999/92/EC, ATEX 137: A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is not likely to occur in normal operation but, if it does occur, will persist for a short period only. This zone requires equipment group 3D (1D and 2D are also possible). Combics series: CIS indicator + Option Y2 Can be used with Option Y2 in zones 2 and 22 With built-in A/D converter for analog platforms for load cells up to 32 t Type of ignition protection: restricted breathing enclosure, ATEX: II 3GD EEx nr II T6 T80 C Stainless steel housing with cable glands 3 data interfaces standard Can be networked with up to 8 client devices Combics series: CAPx platforms + Option Y2 Weighing capacity from 0.1 g to 3 t, also Type of ignition protection: non-sparking, ATEX: II 3 GD EEx na II T6 T80 C Low-profile, stainless steel design Other materials optional for the load plate, underframe and lift-deck system Combics series: CW.S. complete scale + Option Y2 Weighing capacity from 0.1 g to 3 t, also Type of ignition protection: non-sparking, restricted breathing enclosure, ATEX: II 3 GD EEx nar II T6 T80 C 4 display unit versions featuring different levels of applications Stainless steel material, 11 different sizes Customized equipment and features (interfaces, materials ) optionally available IFS and IFP flat-bed scales with Option Y2 Weighing capacity from 0.1 g to 3 t, also ( e e ; class l) IFS material: stainless steel; IFP material: painted steel; other materials optional Type of ignition protection: non-sparking, ATEX: II 3GD EEx na II T6 T80 C High-grade material and outstanding workmanship design ideal for use in the pharmaceutical industry Easy to clean thanks to load plate lifting mechanism Exceptionally low-profile design for especially easy loading High protection rating: IP68 IUS and IUG pallet scales with Option Y2 Weighing capacity from 0.1 g to 1.5 t, also ( e e ; class l) IUS material: stainless steel; IUG material: galvanized steel Type of ignition protection: non-sparking, ATEX: II 3GD EEx na II T6 T80 C High protection rating: IP68 Factory series: IS digital precision platforms Weighing capacity from 0.1 g to 300 kg, also Type of ignition protection (150, 300 kg): restricted breathing enclosure, ATEX: II 3 GD EEx nr II T6 T80 C Type of ignition protection (16 64 kg): non-sparking, ATEX: II 3 GD EEx na II T4 T80 C IP65 (without built-in motorized calibration weight) RS-232C data interface standard (other optional data interfaces can be installed) For use as a digital, explosion-protected weighing sensor connected to PLCs, or a max. of 2 platforms can be connected to the Combics indicator (in a hazardous area) or to a series X5 controller (in the nonhazardous area) Can be networked with up to 8 client devices PR1720 fieldbus transmitter PR1720 transmitters Modern field instrumentation for tank and hopper scales Type of ignition protection (PR1720 fieldbus transmitters): non-sparking, ATEX: II 3 GD EEx na II T4 T100 C IP65 Intrinsically safe load cell power supply Fieldbus protocols, interface (also analog output) Smart calibration via load cell data Field housing: IP65 Discovery metal detector: For detection of metal particles Type of ignition protection, ATEX: ll 3 D T80 C IP5X Safeguards against machine damage and downtimes Optimal compliance with legal requirements, e.g., HACCP Assures product quality in compliance with ISO9001 Load cells Wide capacity range up to 300 t Various designs (tension and bending beam load cells, compression load cells, PanCake level cells, specialty load cells) Zone 22 Explosive Dusts Category ll 3 D 19

7 Combics indicator Combics platform IS weighing platforms IFSX IFP flat-bed scale IUS IUG pallet scale Configurations with Combics and Option Y2 for zone 22 Combics platform + Option Y2 Flat-bed scale + Option Y2 Combics indicator + Option Y2 Pallet scale + Option Y2 IS precision platform + Option Y2 Configuration with Sartorius Discovery metal detector for zone 22 Discovery with QA systems, e.g., with SfWin Alternative configuration versions 20

8 EX weigh cell PR1720 fieldbus transmitter Discovery metal detector Configuration with load cells in zone 22 Load cells, e.g., PR62 Fieldbus transmitter PR1720 PLC or 21

9 Typical weighing equipment configuration for zone 1 (II 2 G) and zone 21 (II 2 D) II 2 G Nicht explosionsgefährdeter Bereich Power supply (110V-230V) 24-V module Power supply (110V-230V) Rechargeable battery 24-V module ib Interface converter or Zener barrier PLC e.g., FC scale Foot switch Data printer Alternative configuration versions Aside from explosion-protected scales, zones 1, 20 and 21 equipment configurations require ATEX-compliant power supplies and Zener barriers or interface converters for data exchange in the non-hazardous area. Flexibility in powering Sartorius products for use in zone 1, 20 or 21 In hazardous areas, the ambient conditions for the power supply vary considerably. Sartorius has responded to these requirements by offering explosion-protected scales that are independent of a specific power supply design. You can choose from the following power supplies that are available in the various international versions: Power supply for installation in a hazardous area ( V) Rechargeable battery for installation in a hazardous area ( V) Power supply for installation in a non-hazardous area ( V) 24-volt module for installation in a non-hazardous or hazardous area (24 VDC); can also be installed in a control panel Flexible data communication between hazardous area equipment and non-hazardous area peripherals Usually, weighing equipment is connected to a report printer, a or a PLC located in the non-hazardous area. Both the hazardous and the non-hazardous area must be electrically isolated from each other. Sartorius offers various solutions for isolation of intrinsically safe from non-intrinsically safe circuits. These solutions are compatible for all Sartorius product families: Zener barriers for different applications A universally configurable interface converter that can also be installed in zone 2 Independently of the particular data interface selected for the scale (RS- 232C, RS-422, RS-485, TTY 20 ma) and the transmission rate, Sartorius Zener barriers and interface converters enable communication over various distances between peripherals in the nonhazardous area and the hazardous-area equipment. Up to 8 client weighing devices with an RS-485 data interface can be networked in a hazardous area. 22

10 Typical weighing equipment configuration for zone 2 (II 3 G) and zone 22 (II 3 D) Combics platform + Option Y2 e.g., Combics indicator + Option Y2 PLC Data printer Alternative configuration versions

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas Intrinsic Safety Intrinsically Safe Solutions Accurate Weighing in Hazardous Areas Accidents in hazardous areas can have dramatic consequences for businesses in terms of both human life and profit. Intrinsically

More information

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,

More information

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE PUE HX5.EX explosion-proof hazardous area indicator ATEX APPROVAL PUE HX5.EX is a cutting-edge weighing indicator, designed to

More information

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt Airo Wireless Intrinsically Safe White Paper Written By: David Schmitt Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection certification for safe operation with electronic

More information

ATEX, NOMENCLATURE AND CODING

ATEX, NOMENCLATURE AND CODING Technical Notes ATEX, NOMENCLATURE AND CODING The intent of this technical note is approach to the user to the ATEX normative. For this we will begin defining, what is an explosive atmosphere, what are

More information

Smart encoders & actuators

Smart encoders & actuators Declaration of Conformity The manufacturer: LIKA ELECTRONIC SRL 36010 Carrè (VI) - Italy hereby declares that the following products (only when correctly assembled): XAC8018/1PB-14 XAC8018/1CB-14 XAC8018/1FD-14

More information

ATEX, NOMENCLATURE AND CODING

ATEX, NOMENCLATURE AND CODING ATEX, NOMENCLATURE AND CODING The intent of this technical note is approach to the user to the ATEX normative. For this we will begin defining, what is an explosive atmosphere, what are ATEX, as well as

More information

Dräger Polytron 7000 Fixed gas detector

Dräger Polytron 7000 Fixed gas detector DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger Polytron 7000 Fixed gas detector ST-3751-2003 The Dräger Polytron 7000 is a gas detector that can satisfy all toxic and

More information

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES Limassol 20 th August, 2015 RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES This document is intended to provide clarification on the use of FirePro Condensed Aerosol Generators in Potential Explosive

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further. ATEX SOLUTIONS In order to apply a single level for health and safety requirements and to overcome barriers of trade within Europe, national regulations for explosion prevention were harmonized in 1975

More information

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The entrepreneurial basis of the R. STAHL Technology Group follows a long tradition. The product range is aimed at specialised

More information

Installing Foundation Fieldbus H1 in Hazardous Areas. Presented By: Jim Peterson Sr. Applications Engineer MTL/USA

Installing Foundation Fieldbus H1 in Hazardous Areas. Presented By: Jim Peterson Sr. Applications Engineer MTL/USA Installing Foundation Fieldbus H1 in Hazardous Areas Presented By: Jim Peterson Sr. Applications Engineer MTL/USA (Divisions) (Zones) Zone 0 ia) Intrinsically Safe Class I Division 1 Explosion Proof Purged

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-nA Edition 08/207 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical

More information

Beamex. Calibration White Paper. Calibration in hazardous areas

Beamex. Calibration White Paper.   Calibration in hazardous areas Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous

More information

Beamex Calibration White Paper. Calibration in hazardous areas

Beamex Calibration White Paper.  Calibration in hazardous areas Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous

More information

UL HAZARDOUS LOCATIONS SERVICES

UL HAZARDOUS LOCATIONS SERVICES UL HAZARDOUS LOCATIONS SERVICES The international preference in hazardous locations certification for over 100 years ul.com/hazloc Explosive Gas Atmospheres Class I Division S Includes flammable gases,

More information

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward Foundation Fieldbus End Users Council Australia Inc. 9 Corcoran St Duncraig, WA 6023 P.O.Box Z5546 Perth, WA 6831 AUSTRALIA ABN 60 120 236 370 Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and

More information

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS 10.0008 Ex td A20, A20/21, A20/22, A21 IP66 T 0044 37675 Contents 1 Area of applicability 3 2 General information 3 2.1 Zone 20 instruments

More information

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU GENERAL The accidental ignition of an atmosphere containing a large quantity of gas, vapour, mists and/or dust may cause an explosion. Specific

More information

ATEX Safety Switches. More than safety.

ATEX Safety Switches. More than safety. ATEX Safety Switches More than safety. AUDIN - 8, avenue de la malle - 5370 Saint Brice Courcelles Tel : 03.6.0.0. - Fax : 03.6.0.8.0 - Web : http: www.audin.fr - Email : info@audin.fr ATEX products from

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 17065:2012 to provide product conformity certification Newport Business Park New Port Road Ellesmere Port CH65 4LZ United Kingdom Contact:

More information

EtherCAT Box Modules (EPxxxx-xxxx)

EtherCAT Box Modules (EPxxxx-xxxx) Notes about operation of EtherCAT Box Modules (EPxxxx-xxxx) in potentially explosive areas (ATEX) Version: 1.1.0 Date: 2011-06-10 Table of Contents Table of Contents 1 Foreword 1 1.1 Notes on the documentation

More information

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations) Annex II Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations) 1. According to Recommendation L, market surveillance should be included as a flanking area of

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...

More information

Annubar Flowmeter Series

Annubar Flowmeter Series Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA

More information

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here. A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here Introduction Potentially Explosive Atmospheres exist where there is a risk

More information

Products and performance

Products and performance Products and performance February 26, 2016 GfG Instrumentation overview of fixed system products Slide 1 GfG Instrumentation, Inc. 1194 Oak Valley Drive, Suite 20, Ann Arbor, Michigan 48108 Toll free (USA

More information

Danfoss gas detection unit Type GD Heavy Duty

Danfoss gas detection unit Type GD Heavy Duty Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx

More information

PEPPERL+FUCHS GmbH

PEPPERL+FUCHS GmbH Comfort series 1.5 mm embeddable M8x1 4 25 16 13 LED Switching element function NAMUR NC Rated operating distance s n 1,5 mm Installation embeddable Assured operating distance s a 0... 1,215 mm Reduction

More information

EU DECLARATION OF CONFORMITY

EU DECLARATION OF CONFORMITY The Low Voltage Directive (LVD) 2014/35/EU and Electromagnetic Compatibility (EMC) Directive 2014/30/EU. Capacitive level sensor DLS 27N(T) Capacitive level sensor type DLS 27N(T) is designed to bistable

More information

1. GENERAL TECHNICAL INFORMATION

1. GENERAL TECHNICAL INFORMATION 1. GENERAL TECHNICAL INFORMATION 1.1 EXPLOSIVE ATMOSPHERES: Every time that dangerous quantities and concentration of flammable gas, vapors mixture or dust clouds exists, risk of explosions may arise.

More information

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas

More information

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc User manual Explosion-safe window air conditioning system Type series AR-054 II 3 G Ex ic nac h IIC T3 Gc 1. Safety Instructions The window air conditioning series AR-054 is an explosion-safe product suitable

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Relays for use in hazardous locations. Class I, Division 2 and ATEX

Relays for use in hazardous locations. Class I, Division 2 and ATEX Relays for use in hazardous locations Class I, Division 2 and ATEX Explosion protection in North America azardous (classified) locations, as defined in the National Electric Code (NEC), are locations where

More information

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing

More information

Temperature Solutions Line Card

Temperature Solutions Line Card Solutions September 2015 We re Your One Stop Temp Shop One simple model number is all it takes to order our complete, Ready-to-Install Assemblies. They include your choice of: Universal PC-Programmable,

More information

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories Hazardous Locations: Understanding the Basics of Global Compliance Requirements Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories DISCLAIMER/ TERMS OF USE: THE INFORMATION

More information

VERSAFLOW VORTEX Supplementary instructions

VERSAFLOW VORTEX Supplementary instructions VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according

More information

Fire control panels FC360

Fire control panels FC360 Cerberus TM FIT Fire control panels FC360 FC361-ZZ, FC361-ZA, FC361-YZ, FC361-YA Fire control panels (1-loop) for addressable peripheral devices with integrated operating unit One loop with 126 addresses

More information

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC Quick Introduction to TÛV Denmark TÜV Denmark - is a part of the TÜV NORD Group a global Organisation f Certification and Inspection of: Quality Management Systems, Products, Processes and Qualification

More information

Explosion-protected actuator Page 259 of 292

Explosion-protected actuator Page 259 of 292 Explosion-protected actuator Page 259 of 292 9.5 Explosion-protected actuator 9.5.1. What is an explosion? A flammable substance and oxygen, in a certain mixture, must be available to set off an explosion.

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance

More information

Dependable Solutions for Gas Detection

Dependable Solutions for Gas Detection Dependable Solutions for Gas Detection Combustibles/Flammables Standard & Exotic Toxics Oxygen Enrichment/Deficiency Introduction to Sensidyne Established in 1983 - acquired by Schauenburg GmbH in April

More information

Dual certification! Air handling units for potentially explosive atmospheres

Dual certification! Air handling units for potentially explosive atmospheres Dual certification! Air handling units for potentially explosive atmospheres X-CUBE Ex A certified safety product The air handling unit with dual ATEX certification ATEX directive 2014/34/EU applies to

More information

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT Olof Bekker Pr. Eng. BSc. Eng. BML S.MSAIEE, M.NACE Engineering Manager, Electrical COMMITMENT

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 17065:2012 to provide product conformity certification Unit 16-18 Abenbury Way Wrexham Industrial Estate Wrexham LL13 9UZ United Kingdom Contact:

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 8 mm non-flush Stainless steel housing Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 8 mm

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 5 mm flush Usable up to SIL2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching element

More information

Fact Sheet No.2. CompEx Modules EX01 to EX04 for Gas and Vapour Environments

Fact Sheet No.2. CompEx Modules EX01 to EX04 for Gas and Vapour Environments Fact Sheet No.2 CompEx Modules EX01 to EX04 for Gas and Vapour Environments Module Breakdown EX01: The preparation & installation of Ex d, n, e and p equipment in potentially explosive atmospheres. EX02:

More information

PERSONAL COMBUSTIBLE GAS DETECTOR

PERSONAL COMBUSTIBLE GAS DETECTOR PERSONAL COMBUSTIBLE GAS DETECTOR FEATURES Continuous LCD Reading with Back Light Electronic Audio Alarm Visual Alarms include Icons and Red LED Easy Handling Certified Intrinsically Safe Auto Test When

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

Guide for hazardous areas

Guide for hazardous areas Guide for hazardous areas 1 Hazardous areas definitions 2 Gas and dust s 3 Temperature classifications 4 Common flammable gases, vapours and dust types 5 Protection concepts ATEX and IECEx 6 Protection

More information

Bristol Babcock Oil Content Monitor "oil in water"

Bristol Babcock Oil Content Monitor oil in water NORTHEAST CONTROLS INC. ONLINE www.nciweb.net 123 Pleasant Avenue - Upper Saddle River - New Jersey 07458 USA Tel: 201-327-7660 / Fax: 201-327-3242 Bristol Babcock Oil Content Monitor "oil in water" General

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

distributing & controlling system solutions

distributing & controlling system solutions distributing & controlling system solutions your safety our reality Users > Oil and gas industry production storage transport > Petrochemical industry > Chemical industry > Pharmaceutical industry > Food

More information

Intrinsically Safe Transmitters, Option Code 2n

Intrinsically Safe Transmitters, Option Code 2n Installation Manual for Intrinsically Safe Transmitters, Option Code 2n ATEX PERSONAL INJURY WARNING DO NOT USE these products as safety or emergency stop devices or in any other application where failure

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Accessories BF 12 Mounting flange, 12 mm Technical Data specifications Switching element function NAMUR, NO Rated operating distance s n 4 mm Installation non-flush

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 15 mm Installation non-flush Assured operating distance s a 0...

More information

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR SAFETY MANUAL SIL 2 Certified Model FP-700 Combustible Hydrocarbon Gas Sensor Version 2.0 1 SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR This manual addresses the specific requirements and recommendations

More information

(German speaking trainers with English written slides)

(German speaking trainers with English written slides) Kiwa organizes dedicated training courses in Germany (Hannover, Kaufbeuren) especially for German manufacturers and at Kiwa in Apeldoorn, The Netherlands. Language spoken is German and English (German

More information

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM SECTION 40 71 66 ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM PART 1-GENERAL 1.01 SUMMARY A. Ultrasonic clamp-on flow measurement system designed for non-intrusive external to pipe measurement

More information

Using the DewTrak II Dew Point/ Humidity Transmitter

Using the DewTrak II Dew Point/ Humidity Transmitter APPLICATION NOTE 2016_FEB2 DT Rev 10 Using the DewTrak II Dew Point/ Humidity Transmitter The Model DewTrak ll Dew Point/Humidity Transmitter is a compact, cost effective, optical chilled mirror hygrometer.

More information

Ex Products Highest level of safety under the most difficult conditions

Ex Products Highest level of safety under the most difficult conditions Ex Products Highest level of safety under the most difficult conditions Fire protection for potentially explosive areas The Ex Products Nuclear power Logical: The avoidance of flammable materials still

More information

Understanding Hazardous and Explosion-Protection Environments

Understanding Hazardous and Explosion-Protection Environments Understanding Hazardous and Explosion-Protection Environments Explosions occur when a mixture of oxygen and explosive substances develop into explosive gases. When the concentration of a substance in air

More information

Operating Instructions

Operating Instructions Operating Instructions ProVicom MT-65, MT-125 R. STAHL HMI Systems GMBH Im Gewerbegebiet Pesch 14 50767 Köln Version 1.7 Issue: 21.07.2008 R. STAHL HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc

More information

Manual. WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-xxx Definition of Terms, Marking and Installation Regulations. Version 1.0.

Manual. WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-xxx Definition of Terms, Marking and Installation Regulations. Version 1.0. WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-xxx Definition of Terms, Marking and Installation Regulations 2 General WAGO-I/O-SYSTEM 750 General 2010 by WAGO Kontakttechnik GmbH & Co. KG All rights

More information

LET S PLAY IT SAFE. robecco secure center (RSC) G.A.S. inert control (RIC) dust control (RDC) silo automation (RSA)

LET S PLAY IT SAFE. robecco secure center (RSC) G.A.S. inert control (RIC) dust control (RDC) silo automation (RSA) LET S PLAY IT SAFE PREVENTIVE EXPLOSION PROTECTION AND AUTOMATION M ONI TOR CO NTR OL PR OTEC T robecco secure center (RSC) G.A.S. inert control (RIC) dust control (RDC) silo automation (RSA) Scan QR-Code

More information

ATEX Vacuum Pumps in Accordance with the Directive 94/9/EG (ATEX 95) Technical Information

ATEX Vacuum Pumps in Accordance with the Directive 94/9/EG (ATEX 95) Technical Information ATEX Vacuum Pumps in Accordance with the Directive 94/9/EG (ATEX 95) Technical Information 100.90.02 ATEX Certified Vacuum Pumps Oerlikon Leybold Vacuum offers a selection of different types of vacuum

More information

4) Intrinsic Safety Certification

4) Intrinsic Safety Certification INSTRUCTION MANUAL Minialert Intrinsically Safe Round Combined Unit Section Volume Control Tone Generator S2 S3 Tone Selection Switches Fig 1 Simplified block diagram The combined unit is CE marked for

More information

Certified drive and control products for explosion protection

Certified drive and control products for explosion protection Certified drive and control products for explosion protection 2 Occupational health and safety: Standards-compliant explosion protection Gases, steam, solvent mist, or dust: Whenever technical operating

More information

OPTIBAR P 1010/2010 C Supplementary instructions

OPTIBAR P 1010/2010 C Supplementary instructions OPTIBAR P 1010/2010 C Supplementary instructions Pressure transmitter Equipment category II 1G / Ga, II 1D / Da in protection type intrinsic safety Exi KROHNE CONTENTS OPTIBAR P 1010/2010 C 1 Safety instructions

More information

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description

More information

Recalibrate the way you look at gas detection

Recalibrate the way you look at gas detection Catalogue Gas detection solution Recalibrate the way you look at gas detection Next generation gas detection for industrial refrigeration The next generation of Danfoss gas detectors are based on a digital

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm

More information

User s Manual YTA610 and YTA710 NEPSI Certification

User s Manual YTA610 and YTA710 NEPSI Certification User s Manual YTA60 and YTA70 NEPSI Certification [Option code: /NS, /NS5 and /NF] st Edition . INTRODUCTION Thank you for purchasing the YTA60 and YTA70 Temperature transmitters. This manual contains

More information

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC By: Helge Knudsen, Test&Approval, Niros Telecommunication A/S You may have heard those expressions concerning Transceivers and other electric equipment

More information

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2 Flammable gases Detectors Model DAX 03F DAX 03F- C DAX 03F- H Note for installation, use and maintenance Version 1.2 Introduction This handbook must be read carefully by any person who has or will have

More information

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO PROZESSAUTOMATION Manual SEGMENT PROTECTOR R-SP-!12 FieldConnex TM Segment Protectors with overloaod protection and short-circuit current limitation for the connection of 12 field devices Zone 1 Zone 2

More information

Fact Sheet No.4. CompEx Modules EX01R to EX04R for Gas and Vapour Environments

Fact Sheet No.4. CompEx Modules EX01R to EX04R for Gas and Vapour Environments Fact Sheet No.4 CompEx Modules EX01R to EX04R for Gas and Vapour Environments Module Breakdown EX01R: EX02R: EX03R: EX04R: The preparation & installation of Ex d, n, e and p equipment in potentially explosive

More information

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY Cell Phones Smartphones PDA integrating people, products and processes Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2 APT2000 Series 2-Wire Contacting Conductivity Transmitters Overview The Honeywell Analytical Process Transmitter (APT) 2000 Series transmitter is a two-wire 24-Volt device that continuously measures conductivity,

More information

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors Drive Technology \ Drive Automation \ System Integration \ Services *23511257_0817* Inquiry Forms for Explosion-Proof Gearmotors Edition 08/2017 23511257/EN SEW-EURODRIVE Driving the world Inquiry forms

More information

Official Journal of the European Union

Official Journal of the European Union C 20/16 27.1.2009 Commission communication in the framework of the implementation of the Directive 94/9/EC of the European Parliament and the Council on the approximation of the laws of the Member States

More information

Air Sensor. SAC Ex FCS Ex. Manual ATEX. AQ M-Tech AB

Air Sensor. SAC Ex FCS Ex. Manual ATEX. AQ M-Tech AB Air Sensor SAC Ex FCS Ex Manual AQ M-Tech AB ATEX Air Sensor SAC Ex FCS Ex ATEX Certified AQ M-Tech AB Manual version 2.2 February 2017 2 Air Sensor Manual for SAC Ex and FCS Ex Table of contents 1. Manufacturer

More information

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems Products Solutions Services CT287 Hazardous Area Classifications and Protection Systems Slide 1 Topics covered Types of Hazardous Area classifications with focus on North America Types of hazardous protection

More information

polar zone components and systems for extreme temperatures

polar zone components and systems for extreme temperatures polar zone components and systems for extreme temperatures 2 Our customers safety in their day-to-day work is the main focus of our business. The company has been working towards this for over 80 years

More information

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL SAFETY MANUAL PointWatch Eclipse Infrared Hydrocarbon Gas Detector SIL 2 Certified Model PIRECL Safety Certified Model PIRECL PointWatch Eclipse IR Gas Detector This manual addresses the specific requirements

More information

Hazardous Area Zirconia Oxygen Systems

Hazardous Area Zirconia Oxygen Systems Operating Instructions IM/EXGP-INT_7 Hazardous Area Zirconia Oxygen Systems Interface Electronics Unit ABB The Company We are an established world force in the design and manufacture of instrumentation

More information

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications DL423 DirectLine Sensor Module for Conductivity Measurement Specifications 70-82-03-47 January 2003 Overview DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell as

More information

OPTIWAVE X500 Supplementary Instructions

OPTIWAVE X500 Supplementary Instructions OPTIWAVE X500 Supplementary Instructions OPTIWAVE 3500 C OPTIWAVE 6500 C OPTIWAVE 7500 C Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE X500 1 General safety information 4 1.1

More information

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4 Areas of application The LSG4 alarm unit is used for monitoring industrial systems, e.g. in the following areas: Alarm and hazard stati in production e.g. for monitoring temperature and pressure in reactors

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen It uses a high performance

More information

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac- Carriers Type Universal Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art

More information

Betriebsanleitung / Operation manual. Druckwächtereinheit QUINGUARD / Pressurization Controller QUINGUARD

Betriebsanleitung / Operation manual. Druckwächtereinheit QUINGUARD / Pressurization Controller QUINGUARD Betriebsanleitung / Operation manual Druckwächtereinheit QUINGUARD / Pressurization Controller QUINGUARD 12 V Version 07/2014 Manufacturer... 28 Description... 28 Installation of the QUINGUARD unit...

More information