203RE ph v 1.0 Instructions
|
|
- Arthur Welch
- 5 years ago
- Views:
Transcription
1 203RE ph v 1.0 Instructions \\Elmacron-server\gemensam\Instruktioner\Instruktioner i Word\203RE\Engelska\203 RE ph_eng.doc
2 TABLE OF CONTENTS INTRODUCTION... 2 DEFAULT SETTINGS... 2 INSTALLATION... 3 Casing... 3 Mounting... 3 Electrical installation... 3 SETTINGS... 5 Relay functions... 5 Parameter settings... 6 CALIBRATION... 7 SPECIFICATIONS... 9 NOTES
3 INTRODUCTION 203RE is a new CE-approved series of controllers from Elmacron AB. In the series, there are instruments for ph, conductivity, Redox, Redox mv and temperature measurement/ control. 203RE is easy to program, calibrate and use. All parameters are entered/changed with the function keys on the front panel. The 2-lined display gives you running information during the setting modes. During normal operation the display shows actual ph, configured temperature compensation, control output status and alarm output status. To avoid unintended interruption during operation, the controller needs an accept to enter edit functions. DEFAULT SETTINGS When delivered, 203RE have the following default settings. Output 0-20 ma Temperature compensation Manual, 20 C Alarm delay 10 sec Shutdown Off Offset ph = 7.00 Low buffer ph = 4.00 High buffer ph = Slope 100% ( 20 ) Limit 1 ( low ) ph = 6.00 Limit 2 ( low ) ph = 8.00 Alarm limit 1 ( low ) ph = 4.00 Alarm limit 2 ( high ) ph = Regulation On/Off regulation XP-band 5.0% Frequency 50 imp/ min PWM 10 sec 2
4 INSTALLATION Casing The casing is made of die-cast polystyrol with a transparent front cover that is closed with a snaplock. The connection terminals are located in a separate partition at the lower part of the instrument. At the bottom of the instrument there are six cable glands for the electrical connections. The protection class is IP65. Mounting The instrument is designed for wall mounting. Be sure that the instrument is mounted at a non-vibrating place. Mounting is done with two screws ( 7 mm). Fastening is carried out through the two mounting brackets at the rear side of the instrument. Electrical installation EN1L1 RE1 RE2 RE3 485 ELEC Pt100 REC It is recommended that each instrument is provided with a separate power switch. The electrode coax cable must be protected by a screen and may not be installed near power cables. Avoid extension of cables. The connection terminals are located in a separate space at the lower part of the instrument. Connection of the power supply Connect the power supply to terminal 1 (earth), terminal 2 (zero) and terminal 3 (live). Connection of dosing pumps and valves ( control outputs ) Connection to relay output 1 (RE1) is made through terminal 4 and terminal 5, connection to relay output 2 (RE2) is made through terminal 6 and terminal 7. Connection to an external alarm Connect alarm (RE3) to terminal 8 and terminal 9. Connection of the electrode Electrode cabling is a very critical part for the safety and accuracy in measuring. o o o o use a low noise coax cable between the electrode and the input terminal on the controller. low noise cables has, in general, a black semi-conductive sheath between the centrewire insulation and the shield. Remove this sheath. keep the cable away from power wires max recommended length of cable is 10 meters Connect the centre ( glass electrode ) of the coax cable to terminal 12 ( ELEC - ) Connect the shield ( reference ) of the coax cable to terminal 13 ( ELEC + ) 3
5 Connection of a temperature probe ( RTD Pt100 ) When automatic temperature compensation is configured, a Pt100-probe is connected to terminal 14 and 15. The temperature sensor has to be installed in the same solution being measured, close to the electrode either in-line or in the tank When manual temperature compensation is configured a 107 Ω-resistor is connected to the temperature input. Connection of a recorder Connect the recorder to terminal 16 ( REC + ) and terminal 17 ( REC - ). 4
6 SETTINGS Relay functions The relay function gives you several configuration possibilities to make it easy for you to adapt the controller to your specific process. To see what regulation parameters you have to choose is mentioned in the specifications to your pump, valve etc. which is to be connected to 203RE. First you make a choice between On/Off and proportional regulation. Under the proportional regulation You can choose between pulse and frequency related regulation Then You set the limits for relay 1 and relay 2; they can be set high/high, low/low, high/low and low/high. - Set Period Time 10. <+>< ><=> 6.75 ph R1 R2 A Running mode + Press <+> and <-> simultaneously to activate the setting menu. Proceede? <+>Yes...< >No + Press <+> to confirm, <-> to abort Cal.<+> Relf.< > Setp.<M> Exit<=> Relay control! <+>Xp < >Lim<=> + Confirm with <=> Relay control! <+>PWM < >FRQ<=> + Confirm with = Set PULSE/Minute 50. <+>< ><=> Set Prop. Band % 5. <+>< ><=> Relay[1] limit! <+>Max< >Min<=> Relay[1] limit! 6.00 <+>< ><=> Relay[2] limit! <+>Max< >Min<=> Relay[2] limit! 8.00 <+>< ><=> Press <-> to activate settings of relay functions Choose <-> for On/Off<->regulation or <+> for proportional regulation Choose <+> for pulse width modulated regulation or <-> for frequency related regulation. Set the desired period time (or number of pulses/minute). Set the desired proportional band in % of total range. Choose if relay 1 is set for min or max function with <+> or <-> Set the limit value for relay 1 with <+> or <-> Choose if relay 2 is set for min or max function with <+> or <-> Set the limit value for relay 2 with <+> or <-> = Confirm and return to main menu with <=> 5
7 Parameter settings Before starting up the controller the following parameters has to be set: temperature compensation (manual or automatic), temperature at manual temperature compensation, calibration points, alarm limits, shutdown at alarm and output settings ph R1 R2 A Running mode + Press <+> and <-> simultaneously to activate the setting menu. Proceede? <+>Yes...< >No + Press <+> to confirm, <-> to abort Cal.<+> Relf.< > Setp.<M> Exit<=> M Set Temp.Comp <+>Man< >Au<=>Ok Press M to activate parameter settings. Choose <+> for manual temperature compensation or <-> for automatic + Confirm with<=> Set Temp. C 20.0 <+>< ><=> In manual temperature compensation mode: set the correct temperature with <+> and <-> buff 7.00 [Z] <+>Fw< >Bw<=>Ok Set calibration point 1 (Offset). (Choose between ph 6.86, ph 7.00 and ph 6.99). buff [H] <+>Fw< >Bw<=>Ok Set calibration point 2 (High). (Choose between ph 8.96, 9.00, 9.95, 10.00, and ph 12.52). buff 4.00 [L] <+>Fw< >Bw<=>Ok Set calibration point 3 (Low). (Choose between ph 1.68, 2.00 and ph 4.00). Alarm Delay[sec] 10. <+>< ><=> Set the alarm delay (in seconds) Alarm Lim H[pH] <+>< ><=> = Alarm Lim L[pH] 4.00 <+>< ><=> Auto Shutdown? <+>On < >Of<=>Ok Set alarm limit 1 (high). When the measured value is higher than set alarm limit the alarm output is activated. Set alarm limit 2 (low). When the measured value is lower than set alarm limit the alarm output is activated. Choose if function "Shutdown at alarm" is On <+>or Off <-> Record current! Set the output range. Choose between 0-20 ma <-> and 4-20 ma <+>4mA < >0A<=>Ok <+> = Confirm and return to main menu with <=> 6
8 CALIBRATION Preparation Take the electrode out of the measuring tank and clean it according to: Slightly dirty electrode: rinse with distilled water and wipe of carefully with soft paper. NOTE! It is very important that glass bulb and reference diaphragm are free from fat and contamination. Dirty electrodes can be cleaned in diluted hydrochloric acid ( 10 %) or, in presence of fat/oil, wash with a grease solvent, alcohol etc. After cleaning, immerse the electrode in a beaker with tap water for about 2-5 minutes to stabilize. Calibration 6.75 ph R1 R2 A Running mode + Press <+> and <-> simultaneously to activate the setting menu. Proceede? <+>Yes...< >No + Press <+> to confirm, <-> to abort Cal.<+> Relf.< > Setp.<M> Exit<=> + Press <+> to activate calibration mode Cal <C> Choose <+> for calibration at the first calibration point (Offset) + Immerse the electrode in the first buffer (in the example ph7) Cal <C> C is blinking. Wait until the value on the display is stabilized. + Confirm with<+> Calibrate[ok] If calibration at a next point is wanted, press <+>. Otherwise press <=> to end the calibration. + Rinse the electrode membrane carefully with distilled water. Cal <C> Choose <+> to calibrate at the second calibration point. + Immerse the electrode in the second buffer (in the example ph10) Cal <C> C is blinking. Wait until the value on the display is stabilized. + Confirm with<+> Calibrate[ok] If calibration at a next point is wanted, press <+>. Otherwise press <=> to end the calibration. + Rinse the electrode membrane carefully with distilled water. Cal <C> Choose <+> to calibrate at the third calibration point. 7
9 + Immerse the electrode in the third buffer (in the example ph4) Cal <C> C is blinking. Wait until the value on the display is stabilized. + Confirm with<+> Calibrate[ok] Rinse the electrode membrane carefully with distilled water before putting it bank in the measure tank. = Confirm and return to main menu with <=> NOTE! If E is shown after <C> E, the uncalibrated value is outside the limits to perform a calibration. Investigate the buffer solution or replace the electrode and try again. 8
10 SPECIFICATIONS Instrument Version 1.0 Weight 1.0 kg Dimensions B x H x D 195 x 200 x 105 mm Max length, electrode cable 10 meters Display 2x16 sign alphanumeric LCD-display with backlight Board Keyboard with four push buttons Connections Terminals Power supply 230 VAC, 50 Hz Backup > 10 years Range, ph ph Accuracy, ph ± 0.01 ph Resolution, ph ± 0.01 ph Zero adjustment Range ± 1.5 ph, 0.01 ph/ step Slope +10%, -20% Calibration 1, 2 or 3 points Temp. range C Temperature compensation manual automatic with connected 2-wire Pt 100-sensor Input ph-inp z = Ω Outputs Output 0-20 ma / 4-20 ma Max load, output 700 Ω Alarm relay Closing contact, tentionfree Time delay Adjustable sec Shutdown On / Off Set-point controls Closing contact, tentionfree Control outputs Re1, Re2 Proportional band, XP % Frequency imp/min, pulse length Ton = 100 ms PWM ( Pulse Width Mode ) T = sec ( 0-99% ) Ton min = 100 ms ON/OFF Hysteresis= ± 0.05 ph 9
11 NOTES Settings Output Temperature compensation Alarm delay Shutdown Offset Low buffer High buffer Slope Limit 1 ( low ) Limit 2 ( low ) Alarm limit 1 ( low ) Alarm limit 2 ( high ) Regulation XP-band Frequency PWM 10
JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS
OPERATION MANUAL THE JENCO MODELS 3672, 3673, 3675 1/4 DIN ph/orp CONTROLLER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS INTENDED USE AND GENERAL INTRODUCTION The models 3672, 3673 and
More informationCorporate Profile. needs and product demands. CON 08X /03 Rev 0
Corporate Profile A leader in the field of electrochemical instrumentation, Eutech Instruments is a dynamic company rapidly positioning itself globally as a leading manufacturer of electrochemical instrumentation
More informationTable of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11
Table of Contents 1. OVERVIEW... 3 2. SYSTEM LAYOUT... 4 3. SPECIFICATIONS... 8 3.1 SYSTEM COMPONENTS...9 3.2 PLC INPUTS AND OUTPUTS...9 3.3 FUNCTION KEYS...10 3.4 DEFAULT SET POINTS AND TIMERS...10 4.
More informationKONTROL INVIKTA Double
KONTROL INVIKTA Double PACK CONTENTS A) "Basic POOL Double" ph and REDOX control device B) PVC Crystal 4x6 with suction device (2 m) C) Polyethylene delivery hose (3m) D) Attachment screw (=6 mm) E) Foot
More informationJENCO ELECTRONICS, LTD.
OPERATION MANUAL THE JENCO MODEL 3677 1/8 DIN ph/orp CONTROLLER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISON INSTRUMENTS GENERAL INTRODUCTION The model 3677 is a precise instrument for the measurement
More informationUser Guide IM/AX4CO4 Rev. K. AX413, AX430, AX433, AX436 & AX438 Single and dual input analyzers for high level conductivity
User Guide IM/AX4CO4 Rev. K AX413, AX430, AX433, AX436 & AX438 Single and dual input analyzers for high level conductivity The Company We are an established world force in the design and manufacture of
More informationUse this Specification Template to develop a specification to be used for requesting a quote or defining a job work description.
Use this Specification Template to develop a specification to be used for requesting a quote or defining a job work description. This document is a framework for creating a specification. It may contain
More informationHydroMaster USER S GUIDE HM-500
HydroMaster USER S GUIDE HM-500 TABLE OF CONTENTS 1. INTRODUCTION... 2 A. Overview... 2 B. What s Included... 2 C. Housing Description... 2 D. Specification... 3 E. LCD Display... 4 F. Switch and Keypad
More informationORP (mv) Controller Model: ORP-XP2. UP DOWN ENTER Time & Date Main Menu Alarm Reset
Instruction Manual ORP (mv) Controller Model: ORP-XP2 Power Control Alarm Comms UP DOWN ENTER Time & Date Main Menu Alarm Reset Supplied by: Convergent Water Controls Pty Ltd 2/4 Huntley Street, PO Box
More informationJENCO INSTRUMENTS, INC. JENCO ELECTRONICS, LTD ARJONS DR., SUITE C P.O. BOX LINKOU-117
OPERATION MANUAL JENCO MODEL 6173 MICROCOMPUTER BASED ph/mv/temperature BENCH METER JENCO INSTRUMENTS, INC. JENCO ELECTRONICS, LTD. 7968 ARJONS DR., SUITE C P.O. BOX LINKOU-117 SAN DIEGO, CA 92126 TAIPEI
More informationMEAS CAL ALARM WASH CONF APT4000 TC
APT4000 Series Toroidal Conductivity Transmitters Overview 70-82-03-42 3/01 Page 1 of 8 Specification The Honeywell Analytical Process Transmitter (APT) 4000 Series transmitter continuously measures conductivity,
More informationF4 Process Controller Installation and Operation Guide
F4 Process Controller Installation and Operation Guide 1.Introduction 1.1.Highlight Features Space saving, only 55mm panel depth required Higher sampling rate (1mS) results in better control performance
More informationCELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL
Operation Manual Celltrol II Bioreactor Control System Page 1 of 33 Table of Contents 1) Introduction... 3 1.1) Scope of Document... 3 1.2) Control System Overview... 3 1.3) Introduction to Celltrol II...
More informationMultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price
MultiMeter 44 Transmitter-regulator with 1, 2 or 3 channels MultiMeter 44 is a modular meter that can be configured with one, two or three channels. It can be delivered with only one measuring channel,
More informationProduct waste disposal - Protection of the environment:
Product waste disposal - Protection of the environment: In accordance with the provisions of the Waste Electrical and Electronic Equipment (WEEE - 2002/ 96/ EC) Directive, used electric and electronic
More informationOPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS
OPERATION MANUAL THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS GENERAL INTRODUCTION The model 6230 is a precise instrument
More informationMEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description
APT4000 Series 4-Wire ph Analyzers 70-82-03-44 10/03 Page 1 of 8 Specification Overview The Honeywell Analytical Process Analyzer (APT) 4000 Series 2 continuously measures ph or ORP in industrial processes
More informationMEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description
APT4000 Series 4-Wire ph Transmitters 3/01 Page 1 of 8 Specification Overview The Honeywell Analytical Process Transmitter (APT) 4000 Series transmitter continuously measures ph or ORP in industrial processes
More informationPoolcontrol DYNAMICS. Operating Instructions for users
2010-530-63 Date: 18.03.2011 (Subject to changes without notice) Applicable to software date 911 and date of manufacture 1110 Operating Instructions for users Operating Instructions Notes: dinotec GmbH
More information1 4 DIN Dissolved Oxygen Controller
16. Warranty OAKTON warrants this controller to be free from significant deviations in material and workmanship for a period of one year from date of purchase. If repair or adjustment is necessary and
More informationXWA11V. Walk-In Temp / Door /Alarm / Light Module
XWA11V Walk-In Temp / Door /Alarm / Light Module 1. GENERAL DESCRIPTION Model XWA11V, 100x64 mm format, is a microprocessor-based controller, suitable for temperature monitoring and alarming in a walk-in
More informationRosemount 372. HF Resistant ph sensor. Quick Start Guide LIQ-QSG-372 Rev. C June 2017
Rosemount 372 HF Resistant ph sensor Quick Start Guide LIQ-QSG-372 Rev. C June 2017 hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures and tests its products
More informationRooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422
ºF / º C Rooftop Thermostat Controller Model TRT2422 Description The TRT2422 is a combination controller and thermostat with a built-in scheduler, which is designed for simple and accurate control of single
More informationeed quality electronic design USER s MANUAL
eed quality electronic design www.dem-it.com eed www.qeed.it info@qeed.it ANALOG SIGNAL DISPLAY Q-DISP-T USER s MANUAL The displays Q-DISP-T, prepared for mounting on the back panel, 96x48mm, will allow
More informationOperating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module
XWA11V Walk-In Temp / Door /Alarm / Light Module 1. GENERAL DESCRIPTION Model XWA11V, 100x64 mm format, is a microprocessor-based controller, suitable for temperature monitoring and alarming in a walk-in
More informationOakton TEMP 9500 Advanced Multiparameter Controller
Oakton TEMP 9500 Advanced Multiparameter Controller Models: 89800-03 & 89800-04 Oakton Instruments 625 E Bunker Ct. Vernon Hills, IL 60061, USA 1-888-4OAKTON (1-888-462-5866) info@4oakton.com Contents
More information4TEMPERATURE CONTROLLER
Universal Input Output and High Accuracy 0.5 class 250ms TEMPERATURE ONTROLLER RAMP function PID Auto-tuning Universal input /, Reverse/Direct action selectable Remote/Local input selectable Model and
More informationDixell Installing and Operating Instructions release 7.0
XR160C - XR160D - XR170C - XR170D - XR162C - XR172C CONTENTS 1. GENERAL WARNING 2 1.1 Please read before using this manual 2 1.2 Safety Precautions 2 2. GENERAL DESCRIPTION 2 3. CONTROLLING LOADS 2 3.1
More informationRS Pro Infrared Temperature Sensor
Instruction Manual RS Pro Infrared Temperature Sensor Stock Number: 161-8103 Introduction The RS Pro Infrared Temperature Sensor is a device for measuring the temperature of the surface of a solid or liquid
More informationSerie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)
Serie 5000 Tel. +1 (0)5 222 Fax +1 (0)5 222 12 PRODUCT INTRODUCTI PRODUCT INTRODUCTI 5 Series programmable temperature controller is FineTek's mid-range series of controllers. It uses a 12bit analog /
More informationSentry G3 Machinery Protection Monitor
TECHNICAL INFORMATION Sentry G3 Machinery Protection Monitor CONDITION MONITORING SOLUTIONS The Sentry G3 Machinery Protection Monitor is a high performance signal conditioning unit; providing a universal
More informationUser Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs
User Manual Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-13 and 89800-14 THE STANDARD IN PRECISION MEASUREMENT Table of Contents
More informationUser Manual System 11
User Manual System 11 www.pulseinstrument.com Copyright 2007 Pulse Instruments All Rights Reserved 943 Flynn Road, Camarillo, CA 93012 Phone: (800) 462-1926 Fax: (800) 878-9172 SYSTEM 11 Water Disinfection
More informationXWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring
XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring 1. GENERAL DESCRIPTION Model XWA11V-KIT, 100x64 mm format, is a microprocessor based light and alarm management controller,
More informationEKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual
EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING Manual Contents Introduction...3 Valve compatibility...3 Features...3 Application examples...3 Ordering...3 Operating the EKC 347...4-5
More informationModel AX411 Dual Input Conductivity Analyzer
AX400 Series User Guide Model AX411 Dual Input Conductivity Analyzer ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow
More informationOPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00
OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00 Torrey Pines Scientific, Inc 2713 Loker Ave. West Carlsbad, CA 92010 Phone: 760-930-9400 Fax:
More informationTemperature Controllers
Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65
More informationWIO200 Water In Oil measuring instrument
WIO200 Water In Oil measuring instrument You have made the right decision by choosing a measuring instrument from PAJ Systemteknik. Many customers buy our high standard products every year. There are at
More information99 Washington Street Melrose, MA Phone Toll Free Visit us at
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 48VTR Product Info Page Instruction Manual English / Español
More informationMEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2
APT4000 Series 4-Wire Contacting Conductivity Analyzers Overview 70-82-03-45 10/03 Page 1 of 8 Specification The Honeywell Analytical Process Analyzer (APT) 4000 Series2 continuously measures conductivity,
More informationInstruction Manual. Aquacon Conductivity Controller / Transmitter
Instruction Manual Aquacon 000 Conductivity Controller / Transmitter 68X216853 Rev 1 /2008 Preface This manual serves to explain the use of the Aquacon 000 Series. The manual functions in two ways, firstly
More informationEXPERT TRI-STAR. Temperature controller. User s Manual
Temperature controller r s Manual WARNINGS The warranty can be void if this product is used in a manner not specified by the manufacturer. Every effort has been made to ensure that this manual is complete,
More informationI/A Series 716C 1/16 DIN Temperature Controller
Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of
More informationSentry G3 Machinery Protection Monitor
TECHNICAL INFORMATION Sentry G3 Machinery Protection Monitor CONDITION MONITORING SOLUTIONS The Sentry G3 Machinery Protection Monitor is a high performance signal conditioning unit; providing a universal
More informationInstruction Manual for Water Treatment Controller Model: DIGICHEM Plus + (All software versions to 0.91)
Instruction Manual Instruction Manual for Water Treatment Controller Model: DIGICHEM Plus + (All software versions to 0.91) Fill in serial number here Refer to back page Supplied by: Convergent Water Controls
More informationToroidal Conductivity Transmitters Series APT4000 Specifications
Toroidal Conductivity Transmitters Series APT4000 Specifications 70-82-03-42 March 2001 Overview The Honeywell Analytical Process Transmitter (APT) 4000 Series transmitter continuously measures conductivity,
More informationInstallation Guide. ECL Comfort 210, application A Table of Contents
1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 4 2.1 Before you start.....................................................
More informationInductive. Range. S410/IND Electrodeless Conductivity Sensors
Inductive Range Inductive 0 1.000 μs; 0 10.000 μs; 0 100.000 μs; 0 1 Simens (0 999,999mS) Resolution 1 μs; 10 μs; 100 μs; 1.000 μs S410/IND Electrodeless Conductivity Sensors Low Cost Low Maintenance Online,
More information02/11/2015
CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint
More informationModels AX410 and AX411 Single and Dual Input Conductivity Analyzers
AX400 Series User Guide Models AX410 and AX411 Single and Dual Input Conductivity Analyzers Incorporating Models AX450 and AX455 To Meet United States Pharmacopeia (USP 645) Regulations ABB The Company
More informationCarbon Monoxide Transmitter
Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or
More informationConcise catalogue Water-Industry
2008 Concise catalogue Water-Industry One-channel instruments to measure ph, EC, DO and free chlorine, panel and wall-mounting version. Transmitters - controllers very easy to utilize, the customer does
More informationDissolved Oxygen Measurement liquisys M COM 223 / 253
Technical Information TI 199C/24/ae Dissolved Oxygen Measurement liquisys M COM 223 / 253 Oxygen Controller Benefits at a glance Liquisys M COM 223 Liquisys M COM 253 Due to the modularity of its design,
More informationUser Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs
User Manual Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-03 and 89800-04 THE STANDARD IN PRECISION MEASUREMENT Table of Contents
More informationPH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS
FEATURES DESCRIPTION The model 223pH / ORP Transmitter is ideal for use where economy and reliability are the prime considerations. The basic transmitter is available with either a 115VAC, 220VAC or 24V
More informationOperating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring
XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring 1. GENERAL DESCRIPTION Model XWA11V-KIT, 100x64 mm format, is a microprocessor based light and alarm management controller,
More informationDigi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input
User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with
More informationFloor heating controls, wire connection 1
Floor heating controls, wire connection 1 Contents: Introduction UFH-ZONE-W UFH-EXTRAZONE-W Connection of a thermostat (UFH-THERM-W) o Joining of a thermostat with UFH-ZONE-W or UFH-EXTRAZONE-W Connection
More information02/11/2015
MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS
More informationSeries Temperature Controller Instruction Sheet
Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep
More informationONX908PIT-V1-S1-F1/B Modulating Digital Thermostat
ONX908PIT-V1-S1-F1/B Modulating Digital Thermostat Installation and operation instructions The ONX908PIT-V1-S1-F1 modulating digital thermostats are designed to provide Proportional-Integral (PI) modulating
More informationph COOLING TOWER CONTROLLER
LAKEWOOD INSTRUMENTS MODEL 350 ph COOLING TOWER CONTROLLER INSTRUCTION MANUAL SERIAL #: Lakewood Instruments 7838 North Faulkner Road, Milwaukee, WI 53224 USA Phone (800) 228-0839 Fax (414) 355-3508 http://www.lakewoodinstruments.com
More informationChlorine gas leak detector
INSTRUCTION MANUAL FOR Chlorine gas leak detector with battery back up series M 4510 C 2007 Controlmatik ABW d.o.o. 1 CONTENT 1.0 General description:... 3 2.0 The Unit... 4 3.0 Controls and Displays...
More informationModel 96VTR ¼ DIN Process Controller
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 96VTR Product Info Page INSTRUCTION MANUAL Model 96VTR ¼ DIN
More information2704 Controller Melt Pressure Controller
2704 Controller Melt Pressure Controller A. SUPPLEMENT 2704 MELT PRESSURE CONTROLLER. 2 A.. INTRODUCTION...2 A.2. WHAT IS THE MELT PRESSURE CONTROLLER?...2 a.3. INSTALLATION...3 a.4. WIRING CONNECTIONS...3
More informationManual Vane Anemometer PCE-VA 20
PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business
More informationPROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS
PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min
More informationMICRO CONTROLLER S Z SERIES
Instruction Manual MICRO CONTROLLER S Z SERIES TYPE: PYW 4 5 7 9 Fuji Electric Co.,Ltd. INP-TN1PYWf-E INTRODUCTION You are now the owner of Fuji's digital Temperature Controller. Before using, be sure
More informationTEMPERATURE CONTROL MODULE MODEL R3-TC2
INSTRUCTION MANUAL R3-TC2 TEMPERATURE CONTROL MODULE MODEL R3-TC2 CONTENTS BEFORE USE... 2 POINTS OF CAUTION... 2 COMPONENT IDENTIFICATION... 2 INSTALLATION... 2 EXTERNAL DIMENSIONS unit: mm (inch)...
More informationFRUIT RIPENING CONTROLLER USER MANUAL SZ-FR INDIA
FRUIT RIPENING CONTROLLER USER MANUAL INDIA www.subzero.co Introduction Get to Know Your Controller The is a panel/wall mounted controller dedicated to control fruit ripening process. Features: Key Introduction
More informationTECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB
Summary 1 CONNECTIONS... 3 1.1 TEMPERATURE PROBES...3 1.2 LOW VOLTAGE DIGITAL INPUTS...3 1.3 LIVE DIGITAL INPUTS...4 1.4 RELAY OUTPUTS...5 2 POWER SUPPLY... 6 3 SERIAL CONNECTIONS... 6 4 SOFTWARE... 7
More informationTempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications
Instruction Manual Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Manual PCT-3000 Revision 9/2014 The PCT-3000 series control console incorporates
More informationTC515 and TC600 Installation Manual. a Winters company
THERMOLINE TEMPERATURE CONTROLLERS TC515 and TC600 Installation Manual a Winters company Guarantee 12 months Congratulations on the purchase of this new product. Special care with the design, workmanship
More informationAnalog Room Pressure Monitor RPC Series
Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the
More informationImportant Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.
1 P age Ezeio v9-120317 Eze Cloud Based Monitoring Systems. Created by Intech Instruments Ltd December 2014 Important Supplementary Manual to the main Ezeio manual. Ezeio Controller and the 2400-A16 input
More informationRetractable ph/orp Sensor
Instruction Sheet PN 51A-398R/rev.H January 2011 Model 398R Retractable ph/orp Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. SPECIFICATIONS Measurements
More information2604 Controller Melt Pressure Controller
2604 Controller Melt Pressure Controller A. SUPPLEMENT 2604 MELT PRESSURE CONTROLLER. 2 A.. INTRODUCTION...2 A.2. WHAT IS THE MELT PRESSURE CONTROLLER?...2 a.3. INSTALLATION...3 a.4. WIRING CONNECTIONS...3
More informationProcess & TeMPerATUre UniversAl input DigiTAl MeTers
Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min
More informationDESIGN GUIDELINES. THERMAL building SOLUTIONS
DESIGN GUIDELINES XL-Trace LSZH Self-Regulating Heating Cables for Pipe Freeze Protection Systems THERMAL building SOLUTIONS WWW.PENTAIRTHERMAL.COM Pipe Freeze protection system overview SBS Control Panel
More informationUser's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600
User's Guide ExStik DO600 Dissolved Oxygen Meter II RECALL Dissolved Oxygen DO600 Introduction Congratulations on your purchase of the ExStik DO600 dissolved oxygen / temperature meter which simultaneously
More informationOVEN INDUSTRIES, INC.
OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and
More informationDissolved Oxygen Measurement liquisys S COM 223 / 253
Technical Information TI 199C/07/en No. 51500281 Dissolved Oxygen Measurement liquisys S COM 223 / 253 Oxygen Transmitter Benefits at a glance Measuring transmitter in field or panel-mounted housing Universal
More informationExStik DO600 USER GUIDE. Dissolved Oxygen Meter. 99 Washington Street Melrose, MA Phone Toll Free
USER GUIDE ExStik DO600 Dissolved Oxygen Meter 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com II RECALL Dissolved Oxygen DO600
More informationInductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.
Process Analysis Systems Chem Energy Pharm Food Water Stratos Eco 2405 CondI Inductive Conductivity Measurement Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement
More informationUser Manual SPI-P170 Hydrogen Peroxide
MANUAL SPI-P170 HYDROGEN PEROXIDE User Manual SPI-P170 Hydrogen Peroxide Index SPI-P170... 1 1. INTRODUCTION... 3 2. DESCRIPTION AND OPERATION... 5 3. SAFETY... 7 4. TRANSPORT AND STORAGE... 8 5. ASSEMBLY
More informationJDDT1 - Single Stage Digital Thermostat
JDDT1 - Single Stage Digital Thermostat CAUTION NOTICE: The thermostat must be installed by authorized professionals. It should be located in a place free of vibrations, impacts, and corrosive gases. SET
More informationph/orp-7500 ph/orp Transmitting controller Operation manual
ph/orp-7500 ph/orp Transmitting controller Operation manual V1.2 CONTENT 1 CONCEPTION...1 1.1 MAIN FEATURES...1 1.2 APPLICATIONS...1 1.3 CLASSIFICATIONS...1 1.4 NOTICES...2 1.5 TECHNIQUE INDEX...2 2 INSTALLATION
More informationCLEANROOM MONITOR CR3A Network - Installation Instructions
CLEANROOM MONITOR CR3A Network - Installation Instructions INTRODUCTION The CR3 Series Cleanroom Monitor, was developed specifically to allow for monitoring of confined spaces with accuracy and reliability.
More informationProcess Alarm Module RTA 421
Technical Information TI 074R/24/ae Process Alarm Module RTA 421 Alarm module and power supply for monitoring current or voltage signals Application Areas Plant and machine construction Panel builders
More informationSlope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2
APT 2000 Series 2-Wire ph Transmitters 70-82-03-32 2/00 Page 1 of 8 Specification Overview The Honeywell Analytical Process Transmitter (APT) 2000 Series transmitter is a two-wire 24-Volt device that continuously
More informationK 100 (W) DES. Disinfectant measurement. Applications. Description. Intuitive and simple menu Safety by password function. Disinfection.
Intuitive and simple menu Safety by password function Applications Disinfection Cooling water Process Water K 100 W DES Drinking Water / Beverages Description The instruments of the K100 series are high-quality
More informationVAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1
Model TRO24T4XYZ1 Description The TRO24T4XYZ1 is a combination controller and thermostat. The VAV Thermostat Controller is designed for simple and accurate control of any variable air volume box in a number
More informationAutodos 2000 Monitor for Swimming Pools
Autodos 2000 Monitor for Swimming Pools Installation Manual Contents Installation Suggested Layout for Installation of Autodos 2000 Guide to Installation of an Autodos 2000 System Suggested Connections
More informationARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER
ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER AI-208 (V7.6) User Manual I. Model Code Symbol The type of AI-208 is made up of 4 parts: AI-208 A G L2 Part 1 (Series) Part 2 (Size) Part 3 (Oupt) Part 4
More informationDanfoss gas detection unit Type GD Heavy Duty
Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx
More informationINSTRUCTIONS FOR THE 8500 SERIES MICROPROCESSOR BASED TEMPERATURE CONTROL
INSTRUCTIONS FOR THE 8500 SERIES MICROPROCESSOR BASED TEMPERATURE CONTROL December, 1998 Page 1 949-1275-1 TABLE OF CONTENTS MODEL IDENTIFICATION... 4 INSTALLATION... 4 WIRING... 5 FRONT PANEL KEY FUNCTIONS...
More informationSoftware Version 2.01 LEVEL MONITOR MODEL 220
Software Version 2.01 LEVEL MONITOR MODEL 220 19 April 2000 CONTENTS 1. Introduction 1 1.1 Model Number Designation 2 1.2 Intrinsic Safety Considerations 3 2. Specification 4 3. Operation 6 3.1 Display
More informationTECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB
Summary 1 CONNECTIONS... 8 1.1 TEMPERATURE PROBES...8 1.2 PRESSURE PROBES...9 1.3 LOW VOLTAGE DIGITAL INPUTS...10 1.4 LIVE DIGITAL INPUTS...11 1.5 RELAY OUTPUTS...12 2 VOLTAGE/FREQUENCY INPUT...13 3 POWER
More informationSpecification , July 2015
Technical Information PrecisionLine Controllers EDC21 / EDC22 / EDC23 EASYSET DIGITAL CONTROLLERS Specification 51-52-3-48, July 215 Introduction The EDC21, EDC22 and EDC23 controllers provide precise
More information