1 SAFETY, STRUCTURES AND FIRE DEPARTMENT Reaction to Fire REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013 Notification by the French Government to the European Commission under no 0679 Seule la version française fait foi The French version is legally acceptable Product standard ETA Guide no. 034 (2012): Kits for external wall claddings Owner: Commercial brand(s): Manufacturing unit(s): ALCOA ARCHITECTURAL PRODUCTS S.A.S. 1 rue du Ballon MERXHEIM FRANCE (riveted system and cassette system) The manufacturing unit appears in the associated tests report Brief description: Cladding made of composite panels (see detailed description in paragraph 2) Date of issue: April 03 rd, 2014 The indicated classification does not prejudge the conformity of marketed materials with the samples submitted to the tests and under no circumstances, this document should not be considered as type approval or certification of the product in the sense of the L to L and R 1151 to R 1153 articles of the consumption s code. If this report is being issued by and/or on an electronic medium, only the hard copy of the report signed by CSTB shall prevail in the event of a dispute. The reproduction of this classification report is only authorised in its integral form. It comprises 5 pages.
2 2/5 Classification report No. RA Introduction This classification report defines the classification assigned to the abovementioned product(s) in accordance with the procedures given in the NF EN A1:2013 standard. 2. Product description Cladding system. Composite panel consisting of two precoated aluminium sheets thermally bonded together with a polyethylene film. Tested systems: riveted on metal substructure and cassette on metal substructure. Finishes: 35 µm or PVDF 70/30 35 µm. Nominal thickness of the aluminium facings: 1.47 mm. Overall nominal thickness: 3 mm. Colour: beige.
3 3/5 Classification report No. RA Tests reports and tests results in support of this classification 3.1 Tests reports Name of laboratory Name of sponsor Test identification Test report No. Test method CSTB ALCOA ARCHITECTURAL PRODUCTS S.A.S. 1 rue du Ballon MERXHEIM FRANCE ES RA EN 13823:2002 EN ISO 1716: Tests results Results Test method Product Number of tests Parameters Continuous parameters Mean values Compliance parameters Riveted system finish 35 µm thick 3 FIGRA 0.2MJ (W/s) FIGRA 0.4MJ (W/s) LFS THR 600s (MJ) SMOGRA(m²/s²) TSP 600s (m²) Not reached EN Cassette system finish 35 µm thick 1 Flaming droplets or debris FIGRA 0.2MJ (W/s) FIGRA 0.4MJ (W/s) LFS THR 600s (MJ) SMOGRA(m²/s²) TSP 600s (m²) None Not reached Flaming droplets or debris None EN ISO 1716 External nonsubstantial component 3 Internal nonsubstantial component (per component) PCS (MJ/m 2 ) 0.8 PCS (MJ/m 2 ) 3.5 Product on its whole (worst case: 35 µm finish) PCS (MJ/kg) 0.6 () means: not applicable
4 4/5 Classification report No. RA Classification and direct field of application 4.1 Reference of the classification This classification has been carried out in accordance with clauses , and of the NF EN A1:2013 standard. 4.2 Classification Fire behaviour Smoke production Flaming droplets or debris A2 s1, d0 Classification: A2 s1, d0 4.3 Field of application This classification is valid for the following product parameters: The system described in paragraph 2. An overall nominal thickness of 3 mm. 35 µm thick and 35 µm thick PVDF 70/30 finishes. This classification is valid for the following end use conditions: Riveted or screwed system and cassette system on metal substructure. Without insulating material or with any A1 or A2s1,d0 class mineral wool insulating material behind the metal substructure With or without air gap. Without substrate or with any A1 or A2s1,d0 class substrate with a density 652 kg/m 3.
5 5/5 Classification report No. RA Limitations The present document does not represent type approval or certification of the product. The classification assigned to the product in this report is appropriate to a declaration of performance by the manufacturer within the context of system 3 attestation of conformity and CE marking under the European Construction Products Regulation (regulation UE no. 305/2011). The manufacturer has made a declaration, which is held on file. This confirms that the products design requires no specific processes, procedures or stages (e.g. no addition of flameretardants, limitation of organic content, or addition of fillers) that are aimed at enhancing the fire performance in order to obtain the classification achieved. As a consequence the manufacturer has concluded that system 3 attestation is appropriate. The test laboratory has, therefore, played no part in sampling the product for the test, although it holds appropriate references, supplied by the manufacturer, to provide for traceability of the samples tested. ChampssurMarne, April 03 rd, 2014 The Technician Responsible for the test The Head of Reaction to Fire Unit Maxime BAUER Gildas CREACH..END OF THE CLASSIFICATION REPORT
REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013
SAFETY, STRUCTURES AND FIRE DEPARTMENT Reaction to fire REACTION TO FIRE CLASSIFICATION REPORT No. RA140265 ACCORDING TO THE EUROPEAN STANDARD NF EN 135011+A1:2013 ification by the French Government to
More informationREACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013
SAFETY, STRUCTURES AND FIRE DEPARTMENT Reaction to Fire REACTION TO FIRE CLASSIFICATION REPORT ACCORDING TO THE EUROPEAN STANDARD NF EN 13501-1+A1:2013 Notification by the French Government to the European
More informationREACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013
SAFETY, STRUCTURES AND FIRE DEPARTMENT Reaction to Fire REACTION TO FIRE CLASSIFICATION REPORT ACCORDING TO THE EUROPEAN STANDARD NF EN 13501-1+A1:2013 Notification by the French Government to the European
More informationREACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013
SAFETY, STRUCTURES AND FIRE DEPARTMENT Reaction to Fire REACTION TO FIRE CLASSIFICATION REPORT ACCORDING TO THE EUROPEAN STANDARD NF EN 50-+A:20 Notification by the French Government to the European Commission
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Sponsor Prepared by P.O. Box 70 NL-5750 AB DEURNE Efectis Nederland BV Lange Kleiweg 5 P.O. Box 1090 NL-2280 CB
More informationTFI Report Classification
TFI Report Classification of the Reaction to Fire according to EN 13501-1:2010 Customer Unilin bvba, Division Flooring Ooigemstraat 3 8710 Wielsbeke BELGIUM Product wall covering Wall covering This report
More informationClassification report
- Restricted Classification report Reaction to fire classification report of product Fibo-Trespo Bathroompanels / Respatex Bathroompanels Author Gunn Hofstad SINTEF NBL as Reaction to fire 2012-07-04 Table
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification
More informationClassification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:
Classification of reaction to fire performance in accordance with EN 13501-1: 2007 +A1: 2009 on Superfoil SFNC Prepared for: Boulder Developments Ltd Black Horse Farm Main Street Norwell Nottinghamshire
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554-2665 ZN Bleiswijk Brandpuntlaan Zuid 16-2665 NZ Bleiswijk +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification no.
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification
More informationReaction to fire classification report No C-rev.1
Reaction to fire classification report. 17241C-rev.1 Owner of the classification report Distributor: Vescom bv Churchilllaan 10 Sint Jozefstraat 20 5705 BK Helmond 5750 AB Deurne The Netherlands The Netherlands
More informationClassification Report
Classification Report BASEC Client Report No. Hubbell Inc. (Delaware) L1CPRT801-1 Classification Number of pages in this Report: 6 Issue Date 3 January 2018 Items Tested 1 sample of Copper Communication
More informationCLASSIFICATION REPORT
CLASSIFICATION REPORT NUMBER 251.C.1804.020.EN.01 Work sheet: 21801003 DATE OF ISSUE April 10 th, 2018 NOTIFIED BODY PAGE TEST SPECIMEN CONCERNING TO APPLICANT DATE/S OF TEST AUTORIZED SIGNATORIES Notified
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification
More informationAdditional reaction to fire classification report No H
Additional reaction to fire classification report. 12700H Owner of the additional classification report Antalis International 8 Rue de Seine 92517 Boulogne Billancourt Cedex France Introduction This additional
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Sponsor Prepared by P.O. Box 118 NL-2394 ZG HAZERSWOUDE Efectis Nederland BV Lange Kleiweg 5 P.O. Box 1090 NL-2280
More informationTest Report: ICL/CR15/11/087
Interscience Fire Laboratory Building 63 Haslar Marine Technology Park Haslar Road, Gosport Hampshire PO12 2AG United Kingdom Tel. : +44 (0) 20 8692 5050 Fax.: +44 (0) 20 8692 5155 Email: firetesting@intersciencecomms.co.uk
More informationReaction to fire classification report No C
Reaction to fire classification report. 17911C Owner of the classification report Tapetex B.V. Distributor: Vescom bv Churchilllaan 10 Sint Jozefstraat 20 5705 BK Helmond 5750 AB Deurne The Netherlands
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com CLASSIFICATION CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE
More informationTFI Report Classification
TFI Report Classification of the Reaction to Fire according to EN 13501-1:2010 Customer Stuttgarter Straße 75 74321 Bietigheim-Bissingen GERMANY Product resilient floor covering Product 1: Scala 55 Connect
More informationAdditional Reaction to Fire Classification Report
Additional Reaction to Fire Classification Report MDF Plate Client: Teknos A/S File no.: PCA10461Aad Date: 2018-01-09 Pages: 5 Encl.: 3 Ref: MPA / JAG Notified Body No. 0845 Danish Institute of Fire and
More informationDELTA Classification Report
DELTA Classification Report TEST Reg. no. 19 Reaction to fire classification report for electric cables: Cat 6A U/FTP 500 MHz FRNC Performed for Caleb Cable Industrial Ltd. no.: Page 1 of 9 19 December
More informationCentrum stavebního inženýrství a.s.
Centrum stavebního inženýrství a.s. Fire Technical Laboratory AUTHORIZED NOTIFIED BODY No. 22 BODY No. 9 CLASSIFICATION OF REACTION TO FIRE IN ACCORDANCE WITH EN 5-:27+A:29 Applicant: Příhoda s.r.o. Za
More informationASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS
Revision index Effective date C 15/02/2015 ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS 4, avenue du Recteur-Poincaré, 75782 Paris Cedex 16 Tel. 33 (0)1.64.68.84.97 Fax. 33 (0)1.64.68.83.45
More informationContact person Date Reference Page Richard Johansson P (2) Fire Research
issued by an Accredited Testing Laboratory Contact person Richard Johansson 215-8-13 5P4413 1 (2) Fire Research +46 1 516 56 75 richard.johansson@sp.se 12 ISO/IEC 1725 Sklejka-Pisz Paged S.A Ul. kwiatowa
More informationREACTION TO FIRE TESTS FOR BUILDING PRODUCTS DETERMINATION OF THE HEAT OF COMBUSTION ACCORDING TO STN EN ISO 1716: 2003
mgr. Dušan BERNÁT Fire and Research Institute Ministry of Interior of the Slovak Republic REACTION TO FIRE TESTS FOR BUILDING PRODUCTS DETERMINATION OF THE HEAT OF COMBUSTION ACCORDING TO STN EN ISO 1716:
More informationBS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN 13823: 2010 Reaction to Fire Tests
More informationAnalysis Report
Prestige Carpets bvba Dhr. Dirk Santens Klein Frankrijk 38 9600 RONSE Your notice of Your reference Date 19-06-2013 24-07-2013 Required tests : Identification number T1309624 Information given by the client
More informationCPD Seminar: Importance of Reaction-to-Fire Properties of Materials: Combustibility, Spread of Flame and Smoke Generation
CPD Seminar: Importance of Reaction-to-Fire Properties of Materials: Combustibility, Spread of Flame and Smoke Generation Speaker: Dr. L. K. Sze, Lipmann Technical Director of Date: 23 January, 2018 Disclaimer:
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification
More informationClassification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.
Classification of reaction to fire performance in accordance with BS EN 13501-1: 2007 +A1: 2009 on Sandwich Panel, WP 50 Prepared for: Sandwich Panel Factory Jeddah Saudi Arabia 13 July 2011 0578 Page
More informationBS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN ISO 1716: 2010 Determination Of The
More informationASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS
Revision index Date of implementation B 30/06/2013 ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS 4, avenue du Recteur-Poincarré, 75782 Paris Cedex 16 Tel. 33.(0)1.64.68.84.97 Fax. 33.(0)1.64.68.83.45
More informationFire Test Reports for Interpon D Powder Coatings
Akzo Nobel Powder Coatings Ltd. Specification Fire Test Reports for Interpon D Powder Coatings Explanations and collations of key reports and approvals for the UK market. July 2017 Russell Deane Powder
More informationNF MARK THERMOPLASTIC MATERIAL DRAIN OR SEWER SYSTEM OPERATING WITHOUT PRESSURE
Mandated by CENTRE SCIENTIFIQUE ET TECHNIQUE DU BATIMENT Certifying Body 84 avenue Jean Jaurès Champs sur Marne F 77442 MARNE-LA-VALLEE Cedex 2 rue Francis de Pressensé F 9357 LA PLAINE SAINT DENIS Cedex
More informationBS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN 13823: 2010 Reaction to Fire Tests
More informationWhite paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?
White paper by Multimedia Connect Construction Product Regulations* We are all concerned by the safety of persons and property. In 2010, 8 million fires were recorded: they are estimated to have caused
More informationClassification Report Reaction to fire of building elements DIN EN :2007. Class E
Classification Report Reaction to fire of building elements 10-001641-KB02-K06-01-e-01 Translation of Classification report 10-001641- KB02-K06-01-de-01 dated 16. May 2011 Client Deventer Profielen CV
More informationHarmonisation and equivalence of reaction-to-fire performance classification in Europe: a small-scale desk-based study
Harmonisation equivalence of reaction-to-fire performance classification in Europe: a small-scale desk-based study Prepared for: ADCAS 2 Waltham Court, Milley Lane, Hare Hatch, Reading, Berkshire RG10
More informationBS EN ISO : 2010
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN ISO 92391: 2010 Fire Tests For Determination
More informationReaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002
Efectis Nederland BV Efectis Nederland report 2008-Efectis-R0431[Rev.1](E) Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002
More informationForm: KSD-100:10 Page 1 of 3
/Translation from the Lithuanian language/ Form: KSD-100:10 Page 1 of 3 /Logo: GTC; DBS/ REACTION TO FIRE TESTING DIVISION FIRE REASEARCH CENTRE FIRE AND RESCUE DEPARTMENT UNDER THE MINISTRY OF THE INTERIOR
More informationBS EN ISO : 2010
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Fire Tests For Determination Of The Burning
More informationPUBLIC SUMMARY REPORT OF THE EGOLF EN 13823
PUBLIC SUMMARY REPORT OF THE EGOLF EN 13823 ROUND ROBIN 2015-2016 Authors: Anne Steen-Hansen, RISE Fire Research Nick Neumann, MFPA Leipzig Richard Johansson, RISE Safety Marina Andersson, RISE Safety
More informationCLASSIFICATION IN REGARD OF REACTION TO FIRE according to EN :2007
SWORN TRANSLATOR & INTERPRETER OF THE ENGLISH LANGUAGE Provincial Court Gdansk, Poland EWA KOCIK 7/9 Czubinskiego Street 80-215 Gdansk tel. (48) 58 345 50 76, (48) 509 209 454 logo : Certified translation
More informationCERTIFICATE OF APPROVAL No ME 5085
CERTIFICATE OF APPROVAL No ME 5085 1 Suite No. 52, 5 th Floor, Martin Burn Building, 1 RN Mukherjee Road, Kolkata- 700001 (West Bengal), India Tel: +91 33 40276600 Have been assessed against the requirements
More informationBS EN ISO : 2010
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN ISO 92391: 2010 Fire Tests For Determination
More informationgent warn nfire No, 16209C Reaction to fire class ification report lntroduction Owner of the classification report
a warn nfire global safety gent Reaction to fire class ification report No, 16209C Owner of the classification report TAPETEX bv VESCOM bv (Distributor) Churchilllaan 10 Sint-Jozefstraat 20 5705 BK Helmond
More informationYour Key to achieving C.E Marking Compliance
Your Key to achieving C.E Marking Compliance As of the 1 st July 2013 The Construction Products Regulation 2011 contains clauses relating to C E marking of products. This will therefore mean that a CE
More informationBS 476: Part 6: 1989+A1:2009
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS 476: Part 6: 1989+A1:2009 Method Of Test
More informationEN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com EN 45545-2: 2013 Summary Test Report Requirement
More informationTNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F
ederlandse Organisatie voor toegepast-natuurwetenschappelijk onderzoek / etherlands Organisation for Applied Scientific Research TO report Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box 49
More informationCPR: EUROCLASSIFICATION & TESTS FOR CABLES
Séance d information «Câbles dans la construction, quoi de neuf?» / Informatiesessie Kabels in de bouw, wat voor nieuws is er? CPR: EUROCLASSIFICATION & TESTS FOR CABLES ervé Breulet CPR & Cables June
More informationNF MARK RIGID NON-PLASTICISED PVC PIPES AND FITTINGS TECHNICAL DOCUMENT 5: BIAXIALLY-ORIENTED PRESSURE PIPE GROUP
Mandated by CENTRE SCIENTIFIQUE ET TECHNIQUE DU BATIMENT Certifying Body 84 avenue Jean Jaurès Champs sur Marne F 77442 MARNELAVALLEE Cedex 2 11 rue Francis de Pressensé F 93571 LA PLAINE SAINT DENIS Cedex
More informationBCTC CARPET TECHNICAL CENTRE
Wira House West Park Ring Road Leeds, LS16 6QL Tel: +44 (0)113 259 1999 Fax: +44 (0)113 278 0306 Web: http://www.bttg.co.uk/bctc Email: CSLeeds@bttg.co.uk 7 September 2010 Page 1 of 7 Client: Rectory Farm
More informationMethod of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.
Method of test defined in IEC 60331-21 for determining the circuit integrity performance of a cable under fire conditions. WF Report Number: 148371 Test Sponsor: FTC - Fabbrica Trentina Conduttori Srl
More informationNew European Fire Testing Classification for Construction Products
New European Fire Testing Classification for Construction Products THE BENCHMARK IN FIRE TESTING EU Construction Products Directive The EU Construction Products Directive (CPD), is the basis of construction
More informationInformation Data Sheet. Fire behavior of decorative high pressure laminates (HPL)
Information Data Sheet Fire behavior of decorative high pressure laminates (HPL) November 2009 1 Introduction Decorative laminate (HPL = High-pressure laminate) can look back on a long tradition of use
More informationBS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com BS EN ISO 92391: 2002 Fire Tests For
More informationAFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)
Page 1 / 7 Construction and tests. Standards: UNE 211025 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº 305/2011: Reaction to
More information~~oeti. Report VN71 O Classification Report. Reference
~~oeti Report VN71 O 137840.3 Classification Report Applicant EGETAEPPER NS lndustrivej Nord 25 7400-Herning Denmark Reference Lenette Ormstrup Application Classification of burning behaviour according
More informationCentrum stavebního inženýrství a.s.
Centrum stavebního inženýrství a.s. Fire Technical Laboratory AUTHORIZED NOTIFIED BODY No. 22 BODY No. 90 CLASSIFICATION OF REACTION TO FIRE IN ACCORDANCE WITH ČSN EN 50-+A:200 Applicant: Příhoda s.r.o.
More informationNot all insulation is the same! from fire testing to real fires.
Not all insulation is the same! from fire testing to real fires. Introduction fire performance is not a simple science > two most important aspects of fire certification for insulation products are: >
More informationSUBJECT: ASSESSMENT FOR INTERNAL SURFACE FINISHES OF LIGHTBETON PANEL FOR COMPLIANCE WITH THE NEW ZEALAND BUILDING CODE(NZBC)
07 th May 2018 Ref: /jobs/18039 Light Beton Panel compliance.doc Plytech International Ltd 23 Business Parade North Highbrook Auckland 2013 Email: craig.f@plytech.co.nz Attention: Craig Floyd SUBJECT:
More informationTest report. NanoPhos coating system EPR and EEN. Name of client: NanoPhos SA. Date: Pages: 5 Encl.: 1 Ref: BP / KTO
Test report NanoPhos coating system EPR and EEN Name of client: NanoPhos SA File no.: PFB10173A Date: 2015-10-14 Pages: 5 Encl.: 1 Ref: BP / KTO Danish Institute of Fire and Security Technology Jernholmen
More informationBS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy
BS 476: Part 7: 1997 on K-Flex IN Clad Foil Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, 36 20877 RONCELLO (MB) Italy 30 th October 2012 0578 Page 1 of 6 Prepared on behalf of BRE Global
More informationReport VNLF Test Report
Report VNLF 081158.1 Test Report Applicant KLEEN-TEX Industries in Europa GmbH Münchner Straße 21 6330-Kufstein Austria Reference Mrs. Antje Schlegel Application Determination ofthe burning behaviour according
More informationBS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.
BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions WF Report Number: 147709 Test Sponsor: FTC - Fabbrica Trentina Conduttori
More informationTest on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in
INFRASTRUCTURE TECHNOLOGIES Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in accordance with AS/NZS 3837:1998 Fire Testing Report Author: Heherson Alarde Report Number:
More informationPassive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection
6 Inside buildings there are two types of fire protection systems: Active Fire Protection and Passive Fire Protection. Both systems should actively work together in the event of a fire. 6.1.1 The four
More informationNF MARK RIGID NON-PLASTICISED PVC PIPES AND FITTINGS
Mandated by CENTRE SCIENTIFIQUE ET TECHNIQUE DU BATIMENT Certifying Body 84 avenue Jean Jaurès Champs sur Marne F 77442 MARNE-LA-VALLEE Cedex 2 11 rue Francis de Pressensé F 93571 LA PLAINE SAINT DENIS
More informationEUROPEAN TECHNICAL ASSESSMENT
EUROPEAN TECHNICAL ASSESSMENT ETA 13/0281 Version 01 Date of issue: 2016-01-15 UBAtc Assessment Operator: Belgian Construction Certification Association Rue d Arlon 53-1040 Brussels www.bcca.be - info@bcca.be
More informationBS 476: Part 6: 1989+A1:2009
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS 476: Part 6: 1989+A1:2009 Method Of Test
More informationDECLARATION OF PERFORMANCE. No EN
DECLARATION OF PERFORMANCE No. 0072 EN 1. Unique identification code of the product-type: Injection System fischer FIS V 2. Intended use/es: Product Bonded anchor for use in concrete Intended use/es For
More informationForbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.
Return address: P.O. box 337, 7500 AH Enschede, TNO Centre for Textile Research Ariënsplein 3 7511 JX ENSCHEDE Forbo Flooring Attn. Mr. A. Tijhof Postbus 13 1560 AA Krommenie Report Sponsor : Contractor,
More informationTECHNICAL DOCUMENT. Technical document Relative to veture products.
TECHNICAL DOCUMENT Built-up cladding products, veture, cladding products and soffit products Technical document 15-02 Relative to veture products. Technical document 15-05 rev 00 28/02/2018 CENTRE SCIENTIFIQUE
More information~,oeti. Report VN Classification Report. Reference
~,oeti Report VN710 140527.2 Classification Report ~ ~ 1so111:e 1102s "\ Applicant EGETAEPPER A/S lndustrivej Nord 25 7400-Herning Denmark Reference Lenette Ormstrup Application Classification of burning
More informationConstruction Products Regulation (CPR) and BS 6701
Construction Products Regulation (CPR) and BS 6701 What you need to know Nancy De Clerck Product Manager Nexans Cabling Solutions Construction Products Regulation (CPR) Scope Performance classifications
More informationDECLARATION OF PERFORMANCE. No EN
DECLARATION OF PERFORMANCE No. 0079 EN 1. Unique identification code of the product-type: fischer injection system FIS EM 2. Intended use/es: Product Metal anchors for use in concrete (heavyduty type)
More informationDECLARATION OF PERFORMANCE. No EN
DECLARATION OF PERFORMANCE No. 0017 EN 1. Unique identification code of the product-type: fischer Concrete screw FBS, FBS A4 and FBS C 2. Intended use/es: Product Metal anchors for use in concrete (heavyduty
More informationSBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING
SBI Single Burning Item - EN 13823 THE BENCHMARK IN FIRE TESTING FTT Single Burning Item (SBI) The importance of the SBI The European Construction Products Directive requires that all European Member states
More informationCentexbel. General certification regulations. Construction products
Centexbel Scientific and Technical centre of the Belgian Textile Industry General certification regulations Construction products 22/03/17 blz. 1 / 8 Contents 1 Introduction 3 2 Object 3 3 Definitions
More informationBelcom Cable excellence engineered through quality. CPR Construction Products Regulation
CPR Construction Products Regulation Index Construction Products Regulation... 3 What is the Construction Products Regulation (CPR)... 4 What is the objective of the CPR... 4 Who does the application of
More informationDECLARATION OF PERFORMANCE. DoP: 0135 for fischer injection system FIS EM Plus (Bonded anchor for use in concrete) EN
DECLARATION OF PERFORMANCE DoP: 0135 for fischer injection system FIS EM Plus (Bonded anchor for use in concrete) EN 1. Unique identification code of the product-type: DoP: 0135 2. Intended use/es: Post-installed
More informationEUROPEAN TECHNICAL ASSESSMENT
EUROPEAN TECHNICAL ASSESSMENT ETA 16/0050 Version draft 01 Date of issue: 2016-03-18 UBAtc Assessment Operator: Belgian Construction Certification Association Rue d Arlon 53-1040 Brussels www.bcca.be -
More informationEUROPEAN TECHNICAL ASSESSMENT
EUROPEAN TECHNICAL ASSESSMENT ETA 16/0050 Version 02 Date of issue: 2016-04-21 UBAtc Assessment Operator: Belgian Construction Certification Association Rue d Arlon 53-1040 Brussels www.bcca.be - info@bcca.be
More informationReview Fire Test Report
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Review Fire Test Report Determination of
More informationMFPA Leipzig GmbH Prüf-, Überwachungs- und Zertifizierungsstelle für Baustoffe, Bauprodukte und Bausysteme
Prüf-, Überwachungs- und Zertifizierungsstelle für Baustoffe, Bauprodukte und Bausysteme Geschäftsbereich III - Dr.-lng. Peter ause Arbeitsgruppe 3.1 - Brandverhalten von Bauprodukten Mathias Claus Telefon
More informationDECLARATION OF PERFORMANCE. No EN
DECLARATION OF PERFORMANCE No. 0021 EN 1. Unique identification code of the product-type: Rebar connection with fischer injection mortar FIS EM 2. Intended use/es: Product Mortar for post-installed rebar
More informationTest Report No: ICL/H17/7967
2294 Notified Body No 2700 Interscience Fire Laboratory Building 63 Haslar Marine Technology Park Haslar Road, Gosport Hampshire PO12 2AG United Kingdom Tel. : +44 (0) 20 8692 5050 Fax.: +44 (0) 20 8692
More informationDECLARATION OF PERFORMANCE
EN 15651-1:2012 EN 15651-2:2012 14 1119 DECLARATION OF PERFORMANCE Sikasil WS-605 S 01 26 03 01 011 9 001000 1024 1. Product Type: Unique identification code of the product-type: 2. Type batch or serial
More informationEuropean Technical Approval ETA-08/0035 This ETA replaces ETA-08/0035 with validity from till
SINTEF Building and Infrastructure P.O.Box 124 Blindern N-0314 Oslo Tel. 47 22 96 55 55 Fax 47 22 69 54 38 Authorised and notified according to Article 10 of the Council Directive 89/106/EEC of 21 December
More informationDECLARATION OF PERFORMANCE. DoP: 0124 for fischer Ceiling Anchor FDZ (Metal anchors for use in concrete (light-duty type)) EN
DECLARATION OF PERFORMANCE DoP: 0124 for fischer Ceiling Anchor FDZ (Metal anchors for use in concrete (light-duty type)) EN 1. Unique identification code of the product-type: DoP: 0124 2. Intended use/es:
More informationBS EN : 2001 & IEC :2000
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN 60695-2-11: 2001 & IEC 60695-2-11:2000
More informationNF MARK RIGID NON-PLASTICISED PVC PIPES AND FITTINGS TECHNICAL DOCUMENT 3: PRESSURE GROUP
andated by CENTRE SCIENTIFIQUE ET TECNIQUE DU BATIENT Certifying Body 84 avenue Jean Jaurès Champs sur arne F 77442 ARNE-LA-VALLEE Cedex 2 11 rue Francis de Pressensé F 93571 LA PLAINE SAINT DENIS Cedex
More informationFrequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry
1. Must a construction product bear the CE marking after 30/06/2013? After 30/06/2013, in order to sell a construction product in the European Union (EU) the manufacturer has the obligation to issue a
More informationCONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE
CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE Carol Harris, EMEA Product Manager WHITE PAPER Molex Connected Enterprise Solutions EXECUTIVE SUMMARY Combustible construction materials
More informationDECLARATION OF PERFORMANCE. DoP: 0094 for Injection System fischer FIS V (Bonded anchor for use in concrete) EN
DECLARATION OF PERFORMANCE DoP: 0094 for Injection System fischer FIS V (Bonded anchor for use in concrete) EN 1. Unique identification code of the product-type: DoP: 0094 2. Intended use/es: Post-installed
More information