1 WATER/WASTEWATER TREATMENT CONTROL SYSTEMS AND SUBSYSTEMS 2000 SERIES CONTROL SYSTEMS: 2000 series are for surface mounting inside a control cabinet Model 2024 Electronic Alternator Duplex (two pump) pump control 2400 SERIES CONTROL SYSTEMS: 2400 series units are for front panel (semi-flush) mounting Model 2402 Pump Status Module Status indication and control of pumps Model 2403 Valve Status Module Status indication and control of 2-position valves Model 2404 Annunciator Provides up to 4 points of alarm annunciation Model 2406 Sequencer Manual sequence selection of process control contacts Model 2407 Alternator Module Duplex, triplex or quadraplex pump control alternator Model 2410 Pump Controller Converts current signal to 4 on-off contact closures plus high, low and signal loss alarms Model 2411 Duplex Pump Controller Converts current signal to 2 on-off contact closures plus high, low and signal loss alarms and alternation Model 2415 Manual Loading Station Auto/Manual loading station with digital indication of analog signal Model 2416 Manual Loading Station Auto/Manual loading station with digital indication of analog signal and output Model 2420 Ratio Station Module Provides ease of use and flexibility in chemical feed systems 3000 SERIES EQUIPMENT: Includes power supplies, loop power supplies, lightning arrestors, remote relays, etc. Model 3800 Line Protection Unit Surge protection for 4-20mADC signal lines Model 3804 Relay Interface Module (4) SPDT 24 VDC relays and terminal blocks mounted on a compact base for track mounting Model 3805 Relay Interface Module (2) DPDT 24 VDC relays and terminal blocks mounted on a compact base for track mounting Model 3824 Relay Interface Module (2) SPDT 24 VDC relays and terminal blocks mounted on a compact base for track mounting Model 3905 Duplex Alternator A reliable, modular unit designed specifically for use with the Model 2410 Controller to provide alternation Model 3907 Loop Power Supply A reliable, modular unit designed specifically for providing loop power for instrument systems

2 COMPLETE CONTROL SYSTEMS designs and builds complete control systems for water and wastewater treatment and other industries. We would be pleased to quote on any requirements you may have of this nature. Registered professional engineering assistance is available if needed Essex Engineering Corp. All Rights Reserved. Printed in U.S.A. Pub. No. INDEX-7000, Rev. 1

3 MODEL 2024 ELECTRONIC ALTERNATOR.... Provides a reliable, flexible system of starting, stopping, sequencing of pumps, blowers, & other devices. FEATURES Modular Construction... Control/Display Circuit board is easily replaced Alarm Silence circuitry for Audible Alarms All functions provided with momentary test switches Built in time delay prevents simultaneous lead/lag unit operation on power-up Lead/lag unit preference easily switch selected Level signals are indicated by L.E.D. lamps DESCRIPTION The Essex Engineering Model 2024 Electronic Alternator is a versatile, reliable system for use in starting, stopping and sequencing pumps, blowers, or other equipment to be cycled. For instance, as the level in a basin or other container changes, the level sensing switches monitor these changes and transmit a signal to the electronic alternator. The alternator, upon receiving the proper signal, will either start or stop the pumps in proper sequence. There are separate turn-on and turn-off points for control, and for high level alarm. Isolated output contacts are provided for pump operation and alarms. The standard unit will operate from a 4 or 5 level point system, and has lock-in or non-lock-in sequence for lag level which can be field modified. High level alarm point can be field set for lock-in, manual reset, or automatic reset. Relay K4 can follow K3 for DPDT switch operation, or be used as an audible device relay, dropping out when Alarm Silence pushbutton is added. The electronic alternator also has a six second time delay to prevent the lag pump from starting simultaneously with the lead pump after a power failure, thus protecting an emergency generator from high inrush starting current requirements.

4 MODEL 2024 SPECIFICATIONS AMBIENT OPERATING TEMPERATURE RANGE 0 to 40 o C POWER INPUT 120 VAC + 10% 10W Max. 12 VDC + 10% 450 madc CONTACT INPUTS ma Max. CONTACT OUTPUTS 10A 240 VAC TIME DELAYS Approximately 6 seconds ELECTRICAL CONNECTIONS - OVERALL DIMENSIONS 2004 Essex Engineering Corp. All Rights Reserved. Printed in U.S.A. Pub. No , Rev. 2

5 MODEL 2402 PUMP STATUS MODULE.... Provides status indication and control of pumps, blowers and other types of motors. FEATURES Bright, long life LED'S give reliable indication of status and monitoring of control functions. HAND-OFF-AUTOMATIC selector switches provide automatic and manual override capability. Provides visual indication of actual motor start or stop. 120VAC/24VD/12VDC power source. Auxiliary output contacts on all front panel switches provide remote monitoring or special "system" interlocks. DESCRIPTION The Essex 2402 Pump Status Module operates in the following manner: Assuming the pump is in the off condition, the green OFF indicator is lit. If the HAND-OFF-AUTO pushbuttons are indexed to AUTO, and an external contact closure occurs which enables the pump or motor to start, an amber CALL indicator will light. Once the pump starts, an auxiliary contact on the motor starter, pressure switch, flow switch, etc. sends a "report back" signal to the 2402 causing the red RUN light to come on and the green OFF indicator and amber CALL indicator to go out. If the pump fails to start, or fails to stop within a 0.2 to 60 second field adjustable time, the red FAIL lamp will flash, indicating trouble and an optional external horn will sound. Depressing the ALM/ SIL button will silence the horn and cause the FAIL indicator to light steadily. If the HAND-OFF-AUTO pushbuttons are indexed to HAND, an amber CALL indicator will light and the unit will operate as described above. Auxiliary contacts are included on the HAND-OFF- AUTO pushbuttons to provide remote monitoring of these switches, or to provide the capability for external interlocking. Field selectable power up or control input timing is standard. This provides staggered starting of unit after a power failure or delayed starting each time the unit is activated. All indicators light for approximately 1 second on power up or can be checked at any time using ALM/SIL button. All of the switches and indicators on the instrument face are sealed for ease of cleaning and the prevention of switch contamination from grease, dirt, etc.. Units are provided with a custom engraved label identifying the use of the Pump Status Module.

6 ELECTRICAL CONNECTIONS MODEL 2402 SPECIFICATIONS AMBIENT OPERATING TEMPERATURE RANGE 0 to 40 o C POWER INPUT 120 VAC + 10% 15W max. 24 VDC + 10% 650 madc max. 12 VDC + 10% 1200 madc max. CONTROL INPUTS Contact closure or NPN transistor; 10 madc 24 VDC CONTROL OUTPUTS NPN solid state output; madc max. per point; 1 output for each pump starter, valve operator, fail alarm, and horn INDICATORS Four front panel LED indicators display status and control functions of unit SWITCHES Sealed contact inputs one each for AUTO, OFF, HAND and ALM/SIL CUTOUT DIMENSIONS OVERALL DIMENSIONS 2008 Essex Engineering Corp. All Rights Reserved. Printed in U.S.A. Pub. No , Rev. 2

7 MODEL 2403 VALVE STATUS MODULE.... Provides status indication and control of two-position valves. FEATURES Long life LED's provide indication of status and monitoring of control functions. OPEN-CLOSE-AUTO selector switches provide automatic operation with manual override. Failure system provides visual indication if valve fails to respond to control signal. Optional audible alarm available. 120VAC/24VDC/12VDC power source. DESCRIPTION Assuming the valve being controlled has limit switches which will signal a fully open, or fully closed position, the 2403 Valve Status Module operates in the following manner: If the valve is closed, the green CLOSED indicator will be lit. If the OPEN-CLOSE-AUTO pushbuttons are indexed to the AUTO mode, and an external contact closure signals the valve to begin to open, the red OPEN indicator will begin to flash intermittently, indicating the valve is to travel to this position. As the valve begins to open, the green CLOSED indicating lamp will go out, and the amber TRAVEL indicating lamp will glow steady, until the valve is fully open. When the valve is fully open the TRAVEL lamp will go out and the red OPEN indicating lamp will glow steady. When operation is reversed and the valve is to close, the red OPEN indicator goes out, the green CLOSED indicator flashes, and the amber TRAVEL light glows steady. When the valve reaches a fully closed position, the amber TRAVEL light will go out and the green CLOSED light will go from a flashing to a steady state condition. A time delay valve failure monitoring system is standard equipment, and is field adjustable from 0.2 to 60 seconds. If the valve does not operate within the specified time, the red FAIL indicating light will come on steadily. When coupled with the Essex Model 2401 Alarm Module, the red FAIL indicator on the 2403 will flash and an audible alarm will sound from the By pushing the alarm button on either the 2401 or 2403, the alarm will be silenced, and the red FAIL light will glow steady. An optional failure relay is available to activate external devices should a valve fail. Auxiliary contacts are included on the OPEN- CLOSE-AUTO pushbuttons to provide remote monitoring of these switches, or to provide the capability for interlocking. By using the electronic CONTROL output, or the FAIL output, a remote 24VDC relay can be used to provide additional contacts and higher current ratings where needed.

8 ELECTRICAL CONNECTIONS MODEL 2403 SPECIFICATIONS AMBIENT OPERATING TEMPERATURE RANGE 0 to 40 o C POWER INPUT 120 VAC + 10% 15W max. 24 VDC + 10% 650 madc max. 12 VDC + 10% 1200 madc max. CONTROL INPUTS Contact closure or NPN transistor; 10 madc 24 VDC CONTROL OUTPUTS NPN solid state output; madc max. per point; 1 output for each valve operator, fail alarm, and horn INDICATORS Four front panel LED indicators display status and control functions of unit SWITCHES Sealed contact inputs one each for AUTO, OPEN, CLOSE and ALM/SIL CUTOUT DIMENSIONS OVERALL DIMENSIONS 2008 Essex Engineering Corp. All Rights Reserved. Printed in U.S.A. Pub. No , Rev. 2

9 MODEL 2404 ANNUNCIATOR.... Visually identifies an abnormal device or condition. FEATURES All solid state circuitry. Optically isolated alarm input contacts. 120VAC/24VDC/12VDC power source. Long life LED indicating lamps. Can accommodate from one to four points per unit. Switch selectable lock-in/nonlock-in and N.O./N.C. alarm input controls. Optional time delay on input. DESCRIPTION The Essex Model 2404 Annunciator is designed to monitor Alarm Contacts and provide "point" indication on the device which is alarming. The standard unit comes equipped to monitor two remote points, but can be optionally equipped to accommodate four points. Each point has a selector switch located on the 2404 drawout PC board, which will allow the point to be set up to monitor a normally open, or normally closed contact. A lock-in/nonlock-in switch is also provided on the PC board for each point. On lock-in or nonlock-in, the alarm indication flashes until acknowledged, whereupon it will light continuously until the field condition is corrected. In lock-in status, the alarming point must be acknowledged before it will reset. In the nonlock-in status, the unit will cease to alarm if the point being monitored returns to normal. An auxiliary output NPN transistor is standard for each alarm point. Transistor follows activation of the field input contact. An optional 0.1 to 60 second time delay is available on the input circuit. This avoids unnecessary alarm indication for those conditions which may be only momentary. ALARM SEQUENCE CHART FIELD ALARM AUDIBLE CONDITION CONTACT LIGHT ALARM* Normal Normal Off Off Alarm Abnormal Flashing On Silence Abnormal On Off Normal Normal Off Off Lamp Test Normal On Off *Mounted Externally

10 ELECTRICAL CONNECTIONS MODEL 2404 SPECIFICATIONS AMBIENT OPERATING TEMPERATURE RANGE 0 to 40 o C POWER INPUT 120 VAC + 10% 15W max. 24 VDC + 10% 650 madc max. 12 VDC + 10% 1200 madc max. CURRENT THRU FIELD TROUBLE CONTACT 5mADC at 24VDC; optically isolated OPTIONAL TIME DELAY 0.1 to 60 second delay is available as a time delay on input before alarm is activated. AUXILIARY OUTPUTS Each alarm point has a NPN transistor auxiliary output capable of driving relays, lights, etc. Maximum transistor 60mADC. CUTOUT DIMENSIONS OVERALL DIMENSIONS 2008 Essex Engineering Corp. All Rights Reserved. Printed in U.S.A. Pub. No , Rev. 2

11 MODEL 2406 SEQUENCER.... Provides sequencing, cascading and/or paralleling of many pumps. FEATURES Front of panel switches provide easy setup of sequencing. Reliable...conservatively designed solid state control circuitry and isolated output circuits assure long operating life. Inputs are optically isolated from the 2406 electronics. Field selectable operation for filling or emptying. Long life LED's for input and output indication. Multiple units may be cascaded and/or paralleled to allow for control of more devices and/or levels. DESCRIPTION The Essex Engineering Model 2406 is a simple, yet reliable unit designed to offer the maximum of versatility in sequencing the operation of pumps or other operating devices. The 2406 is easy to set up for any desired sequence in the operation of up to four devices, with four levels of operation available for each device. As levels increase, or decrease, all of the previous level outputs are de-activated. Simply observe the last level LED which is on, follow the row of switches to the right and observe which units are on. Long life LED's on the front panel provide readily visible indication of the status of each pump and level. Up to four standard Model 2406 Sequencers may be connected together in series or parallel (or a combination of both), to provide for control of up to 16 devices at four levels, or four devices at 16 levels, or 8 devices at 8 levels. Special configurations are available; consult factory. The unit is solidly constructed and uses low Power CMOS Circuitry. It is designed for use in combination with the Essex Engineering Corporation Model 2410 Pump Controller, although it can be used with float switches, controllers, etc. of other manufactures. Technical details are shown on the reverse side of this bulletin.

12 ELECTRICAL CONNECTIONS MODEL 2406 SPECIFICATIONS AMBIENT OPERATING TEMPERATURE RANGE 0 to 40 o C POWER INPUT 120 VAC + 10% 15W max. 24 VDC + 10% 650 madc max. 12 VDC + 10% 1200 madc max. CONTROL INPUTS Contact closure or NPN transistor; 10 madc 24 VDC CONTROL OUTPUTS NPN solid state output; madc max. per point; 4 outputs for unit operation; 1 output for cascade operation INDICATORS Level Output - amber LED Control Output - red LED CUTOUT DIMENSIONS OVERALL DIMENSIONS 2006 Essex Engineering Corp. All Rights Reserved. Printed in U.S.A. Pub. No , Rev. 2

13 MODEL 2407 ALTERNATOR MODULE.... Provides the capability to automatically alternate and sequence up to four pumps, blowers or other devices. FEATURES Variables are field programmable. Provides automatic or manual operation in increasing or decreasing order. Digital indication of lead unit. LED input and output status indicators. Front panel alternate sequence control. First on/first off OR first on/last off sequencing capability. DESCRIPTION The Model 2407 Alternator is a unit that provides for the on-off sequencing of various devices such as pumps, blowers, etc. The unit is extremely flexible with all of the set up parameters being customer settable via plug jumpers and/or switches mounted within the unit. These include first-on/first-off or first-on/last-off selection; sequencing in increasing or decreasing order; unit operation as DUPLEX, TRIPLEX or QUADRUPLEX; operation as alternator, contact in/contact out, or level control unit with latch-up mode. In the level control mode such devices as float switches can be used as inputs and will provide a level control system turning on the outputs in sequence and holding them on WITHOUT the use of external latching relays. When the STOP level float opens, all the outputs will be turned off. Front panel controls provide the operator with the ability to manually select the alternate mode of operation. When indexed to INTERNAL, the unit will alternate the sequence of operation when the last level is de-energized. When indexed OFF, alternation will not occur, except for use of the manual pushbutton on the instrument face. When in the REMOTE mode, the unit can be alternated by the use of an external device such as a time clock, pushbutton, etc.. The input indicator LED's will light as the various input contacts close allowing exact monitoring of the various levels. The output indicators will light as each output is required. If an output device, such as a pump, is indexed OFF, and a contact input is provided to the Alternator, the corresponding output LED will flash at a slow rate indicating the unit is inoperative and allowing the sequence to skip this unit. This feature will provide smooth uninterrupted sequencing of outputs by NOT having to wait for the next level to activate because a unit is inoperative. Also included are lead unit outputs to provide relay switching capability for analog signals, or remote indication of lead unit.

14 ELECTRICAL CONNECTIONS MODEL 2407 SPECIFICATIONS AMBIENT OPERATING TEMPERATURE RANGE 0 to 40 o C POWER INPUT 120 VAC + 10% 15W max. 24 VDC + 10% 650 madc max. 12 VDC + 10% 1200 madc max. CONTROL INPUTS Contact closure or NPN transistor; 10 madc 24 VDC CONTROL OUTPUTS NPN solid state output; madc max. per point; 4 outputs for unit operation; 4 outputs for lead unit indication/control INDICATORS Lead unit - 0.4" LED digit Input - amber LED Output - red LED CUTOUT DIMENSIONS OVERALL DIMENSIONS 2008 Essex Engineering Corp. All Rights Reserved. Printed in U.S.A. Pub. No , Rev. 1

15 MODEL 2410 PUMP CONTROLLER.... A reliable, versatile unit designed specifically for control and monitoring of pumps, tanks, basins, etc... FEATURES Extremely accurate, repeatable and easy to use. Each output may be individually programmed for PUMP UP or PUMP DOWN operation. Digital indication of process variable and setpoints in desired engineering units. Setpoints are adjusted from front of instrument via 25-turn potentiometers. LED output status indicators. Standard and optional time delays are available to override system surging during operation and startup. DESCRIPTION The Essex Engineering Model 2410 Pump Controller is designed specifically for controlling the filling and emptying of tanks, vats or basins by means of one or more pumps. It accepts standard input signal levels of 1-5 VDC, 4-20 madc and special ranges from a continuous level or pressure transmitter. The incoming analog process signal is displayed on the front of the instrument via a 3-1/2 digit LED readout. This same display is also used to set the various turn on and turn off points for the control and alarm functions. Four outputs are available to activate remote relays. Each has an independent turn-on/turn-off setting of 0 to 100% of full scale. A unit indicator lamp is illuminated when its output is energized. Turn-on and turn-off points are set by means of their associated 25-turn potentiometers on the face of the instrument. Each point is set via the read and select pushbuttons which will illuminate a red bar adjacent to the potentiometer being calibrated. The output relays are remote and use low voltage control in order to avoid high voltage transients when the line voltage devices are switched on and off. Fill/empty action is field selectable for each control point via slide switches within the unit. Three alarms, two of which have an LED indicator, are provided. These are high and low level with the signal loss causing the low level LED to flash when activated. The 2410 Controller may be field programmed, via internal DIP switches, to deenergize the control outputs when any alarm condition occurs. An external input signal is also available to deactivate the control and/or alarms when activated. Standard with the unit is a time delay, field adjustable from 0.2 to 60 seconds, to inhibit control and alarm action on power up. This allows system parameters to stabilize before the controller initiates a response. Optional time delay boards are also available to provide various timing functions.

16 ELECTRICAL CONNECTIONS MODEL 2410 SPECIFICATIONS AMBIENT OPERATING TEMPERATURE RANGE 0 to 40 o C POWER INPUT 120 VAC + 10% 15W max. 24 VDC + 10% 650 madc max. 12 VDC + 10% 1200 madc max. ANALOG INPUTS Ω impedance KΩ impedance Factory specials ANALOG OUTPUTS Standard has NONE. Optional: Isolated 0-800Ω LOAD CONTROL INPUTS Contact closure or NPN transistor; 10 madc 24 VDC CONTROL OUTPUTS NPN solid state output; madc max. per point; 4 outputs for unit operation; 3 outputs for alarm indication; 1 output for horn or external alarm indication. INDICATORS 3-1/2 digit, 0.56" LED type display Control Output - amber LED Alarm Output - red LED REPEATABILITY & ACCURACY 0.2% of span, + 1 of least significant digit TIME DELAYS 0.2 to 60 second field adjustable time delay is provided for control and alarm functions to inhibit outputs when unit is initially powered. An optional 0.2 to 60 second, or special range, field adjustable time delay is available for OFF-ON and ALARM timing. CUTOUT DIMENSIONS OVERALL DIMENSIONS 2006 Essex Engineering Corp. All Rights Reserved. Printed in U.S.A. Pub. No , Rev. 3

17 MODEL 2411 DUPLEX PUMP CONTROLLER.... A reliable, versatile unit designed for duplex control and alternation for basins, wetwells, tanks, etc... FEATURES Extremely accurate, repeatable and easy to use. Each output may be individually programmed for PUMP UP or PUMP DOWN operation. Digital indication of process variable and setpoints in desired engineering units. Setpoints are adjusted from front of instrument via 25-turn potentiometers. LED output status indicators. Standard and optional time delays are available to override system surging during operation and startup. DESCRIPTION The Essex Engineering Model 2411 Duplex Pump Controller is designed specifically for controlling the filling and emptying of tanks, vats or basins by means of two pumps. It accepts standard input signal levels of 1-5 VDC, 4-20 madc and special ranges from a continuous level or pressure transmitter. The incoming analog process signal is displayed on the front of the instrument via a 3-1/2 digit LED readout.this same display is also used to set the various turn-on and turn-off points for the control and alarm functions. Two outputs are available to activate remote relays. Each has an independent turn-on/turn-off setting of 0 to 100% of full scale. A unit indicator lamp is illuminated when its output is energized. Turn-on and turn-off points are set by means of their associated 25-turn potentiometers on the face of the instrument. Each point is set via the read and select pushbuttons which will illuminate a red bar adjacent to the potentiometer being calibrated. The lead unit is indicated via green LEDʼs which are adjacent to the #1-Alternate-#2 selector switch. The switch provides manual override of the alternation cycle. Fill/empty action is field selectable for each control point via slide switches within the unit. Three alarms, two of which have an LED indicator, are provided. These are high and low level with the signal loss causing the low alarm LED to flash when activated. The 2411 Controller may be field programmed, via internal DIP switches, to deenergize the control outputs when any alarm condition occurs. External inputs are available to deactivate the control and/or alarms or provide alternation via a push button or time clock contact. Standard with the unit is a time delay, field adjustable from 0.2 to 60 seconds, to inhibit control and alarm action on power up. This allows system parameters to stabilize before the controller initiates a response. Optional time delay boards are also available to provide various timing functions.

18 ELECTRICAL CONNECTIONS MODEL 2411 SPECIFICATIONS AMBIENT OPERATING TEMPERATURE RANGE 0 to 40 o C POWER INPUT 120 VAC + 10% 15W max. 24 VDC + 10% 650 madc max. 12 VDC + 10% 1200 madc max. ANALOG INPUTS Ω impedance KΩ impedance Factory specials ANALOG OUTPUTS Standard has NONE. Optional: Isolated 0-800Ω LOAD CONTROL INPUTS Contact closure or NPN transistor; 10 madc 24 VDC CONTROL OUTPUTS NPN solid state output; madc max. per point; 2 outputs for unit operation; 3 outputs for alarm indication; 1 output for horn or external alarm indication. INDICATORS 3-1/2 digit, 0.56" LED type display Control Output - amber LED Alarm Output - red LED REPEATABILITY & ACCURACY 0.2% of span, + 1 of least significant digit TIME DELAYS 0.2 to 60 second field adjustable time delay is provided for control and alarm functions to inhibit outputs when unit is initially powered. An optional 0.2 to 60 second, or special range, field adjustable time delay is available for OFF-ON and ALARM timing. CUTOUT DIMENSIONS OVERALL DIMENSIONS 2005 Essex Engineering Corp. All Rights Reserved. Printed in U.S.A. Pub. No , Rev. 2

19 MODEL 2415 MANUAL LOADING STATION.... Utilizes analog signals to provide automatic or manual control of various devices. FEATURES 3 1 /2 digit LED display provides large, easy to read digital indication of process. Digital readout of process variable in engineering units or 0 to 100.0%. Ten turn potentiometer provides fine tuning of manual set point. AUTO/MANUAL push button with "READ" push button provides for a manual bumpless transfer. Isolated 4 to 20 madc output. Available for use with 120 VAC,12 or 24 VDC power. DESCRIPTION The Essex Model 2415 Manual Loading Station is a conservatively designed, reliable unit that provides a 4 to 20 madc output which is directly proportional to a voltage or current input. When in the AUTOMATIC mode, the output is directly proportional to the input, and the digital display will indicate the AUTO input signal. While in the AUTOMATIC mode, when the READ button is depressed, the digital display will then indicate the MANUAL value. By manipulating the SET potentiometer the MANUAL value can be made to equal the previously noted AUTO input signal, thereby providing a "bumpless" transfer. Conversely, when in the MANUAL mode, the digital display indicates the manual set point. By depressing the READ button, the digital display will show the AUTO input signal. By releasing the button and adjusting the SET potentiometer, the MANUAL signal can be made to equal the previously noted AUTO signal. Therefore, when going from or to AUTO or MANUAL operation, bumpless transfer can be achieved.

20 ELECTRICAL CONNECTIONS MODEL 2415 SPECIFICATIONS AMBIENT OPERATING TEMPERATURE RANGE 0 to 50 o C POWER INPUT 120 VAC + 10% 15W max. 24 VDC + 10% 650 madc max. 12 VDC + 10% 1200 madc max. CONTROL INPUT IMPEDANCE 1 TO 5 VDC = 1 megohm 4 to 20 ma DC = 250 ohm CONTROL OUTPUT 4 to 20 madc ohm load INDICATOR 3-1/2 digit, 0.56" LED type display REPEATABILITY AND ACCURACY 0.2% of span + 1 digit AVAILABLE OPTION The Model 2415 can be provided as a manual unit only, without the READ button and AUTO/ MANUAL switch. It merely provides a 4 to 20 madc output signal. CUTOUT DIMENSIONS OVERALL DIMENSIONS 2005 Essex Engineering Corp. All Rights Reserved. Printed in U.S.A. Pub. No , Rev. 2

21 MODEL 2416 MANUAL LOADING STATION.... Utilizes analog signals to provide automatic or manual control of various devices. FEATURES 3 1 /2 digit LED displays provides large, easy to read digital indication of both process variable and output signals. Digital indication of process variable in desired engineering units. AUTO to MANUAL bumpless transfer. MANUAL to AUTO field settable timed ramping. Isolated output. Pushbutton increase/decrease control in MANUAL mode. DESCRIPTION The Essex Model 2416 Manual Loading Station is a conservatively designed, reliable unit that provides a 4-20 madc output which is directly proportional to a voltage or current input. Data conversion is very accurate, done via 12-bit A/D and D/A modules. When in the AUTO mode, the output is directly proportional to the input, with the large upper digital display indicating the process variable and the small lower display indicating the percent output. Transfer from AUTO to MANUAL is bumpless with no change in the output. The output can then be increased or decreased via the UP and DOWN pushbuttons. Transfer from MANUAL to AUTO utilizes a field settable ramp time, or the output may be manually changed to match the input, via pushbuttons. The unit contains several field selectable variables such as ramp time from 0.2 to 64 seconds for a zero to one hundred percent output change and zero or non-zero reset on power up. Transferring between AUTO and MANUAL modes is accomplished via the AUTO/MANUAL pushbutton. Indicators are provided to display in which mode the controller is operating. Also available in the unit are several optional features. They include MANUAL ONLY, which has no analog input, no AUTO mode capability, and both displays read the output; or MANUAL ONLY WITH PV, which is the same as the standard unit, bit with no AUTO mode capability.

22 ELECTRICAL CONNECTIONS MODEL 2416 SPECIFICATIONS AMBIENT OPERATING TEMPERATURE RANGE 0 to 40 o C POWER INPUT 120 VAC + 10% 15W max. 24 VDC + 10% 650 madc max. 12 VDC + 10% 1200 madc max. ANALOG INPUTS (standard, except with Manual Only option) Ω impedance KΩ impedance Factory specials CONTROL OUTPUTS Isolated 0-800Ω LOAD SPDT relay contact for AUTO/MANUAL status; 120VAC RAMP TIMING 0.2 to 64 seconds in 7 selectable steps for 0-100% output INDICATORS Process - 3-1/2 digit, 0.56" LED type display Output - 3-1/2 digit, 0.3" LED type display REPEATABILITY & ACCURACY 0.2% of span, + 1 of least significant digit AVAILABLE OPTIONS Manual only - Unit provides a 4-20 madc output signal, using both readouts as OUTPUT display Manual only with PV - Unit provides a 4-20 madc output signal, using Process readout as PROCESS display and small readout as OUTPUT display CUTOUT DIMENSIONS OVERALL DIMENSIONS 2008 Essex Engineering Corp. All Rights Reserved. Printed in U.S.A. Pub. No , Rev. 2

23 MODEL 2420 RATIO STATION MODULE.... Provides ease of use and flexibility in chemical feed systems. FEATURES Provides precision control over the process. Competitively priced. Parallel indicating vertical edge meters allow direct comparison between input and output. Digital thumbwheels provide for accurate set points. DESCRIPTION The Essex Engineering Model 2420 Ratio Station Module is a ratio controller that allows the precise ratioing of input and output signals on a continuous basis. It is designed to be used in water treatment plants and in the chemical processing industry. It offers the ability to control such items as chemical feed equipment, paced from flow, pressure or other type signals, by a multiplication factor of 0.1 to 3.9 times the input level. Standard indication of the ratios is by means of two 31/2" vertical edge meters, calibrated 0-100%. Custom scales are available for special applications. Both the standard input and output signals are 4-20 madc, with the ratio being selected by means of two digital thumbwheels. The ratio range is 0.1 to 3.9, selected in 0.1 step increments, with the accuracy being 0.2% of span. The Model 2420 Ratio Station is designed to be used with the other units in the Essex 2400 series controllers, although it is feasible to incorporate the unit with controllers of other manufacture. Consult the factory for proper application and/or special inputs, outputs and scales.

24 ELECTRICAL CONNECTIONS MODEL 2420 SPECIFICATIONS AMBIENT OPERATING TEMPERATURE RANGE 0 to 40 o C POWER INPUT 120 VAC + 10% 15W max. 24 VDC + 10% 650 madc max. 12 VDC + 10% 1200 madc max. ANALOG INPUTS Ω impedance KΩ impedance Factory specials ANALOG OUTPUTS 0-800Ω LOAD Optional: Isolated 0-800Ω LOAD STANDARD INDICATORS 31/2" vertical edge input meter; 0-100% scale 31/2" vertical edge output meter; 0-100% scale REPEATABILITY AND ACCURACY 0.2% of span RATIO SETPOINT 0.1 to Set by two digit thumbwheel switches in 0.1 increments AVAILABLE OPTIONS Consult factory CUTOUT DIMENSIONS OVERALL DIMENSIONS 2006 Essex Engineering Corp. All Rights Reserved. Printed in U.S.A. Pub. No , Rev. 2

25 MODEL 3905 DUPLEX ALTERNATOR.... A reliable, modular unit designed specifically for use with the Model 2410 Controller to provide alternation. DESCRIPTION The Essex Engineering Model 3905 Duplex Electronic Alternator is a modular unit designed to be used between the Model 2410 Controller and the Series 3800 relay card. Its modular construction provides for easy replacement and/or trouble shooting. It plugs into a standard eight pin socket. The unit has two LED's on the cover to indicate which output will be LEAD on the next activation. ELECTRICAL CONNECTIONS MODEL 3905 SPECIFICATIONS AMBIENT OPERATING TEMPERATURE RANGE 0 to 40 o C Series 3800 Relay Card } +24VDC Output #2 Output # VDC } 4 5 Lead input 6 Lag input 7 COM 1 8 Model 2410 Controller Output POWER INPUT 24 VDC + 10% 15mA maximum MODULE INPUTS Contact closure from either pin 5 or 6 to COM 1mA maximum MODULE OUTPUTS NPN transistor output 60mA maximum PHYSICAL DIMENSIONS 2.375(W) x 1.75(D) x 3.00(H), base to top of LED 2006 Essex Engineering Corp. All Rights Reserved. Printed in U.S.A. Pub. No , Rev. 0

26 MODEL 3907 LOOP POWER SUPPLY.... A reliable, modular unit designed specifically for providing loop power for instrument systems. DESCRIPTION The Essex Engineering Model 3907 Loop Power Supply is designed to provide 24VDC loop power for electronic transmitters. It is designed as a modular unit which plugs into a standard eight pin socket. This facilitates easy replacement and/or trouble shooting by simply unplugging the unit. An LED on the unit cover indicates the presence of 24VDC at the designated pins. With it's 100 madc output capability, it can power up to five (5) 4-20 madc instrument loops ELECTRICAL CONNECTIONS COM MODEL 3907 SPECIFICATIONS AMBIENT OPERATING TEMPERATURE RANGE 0 to 40 o C POWER INPUT 120 VAC + 10% 2W Max. H VAC NOTES VDC is also available at terminal 1 (common) and terminal 8 (+) VAC power source to power supply module should contain a 1/8 A. slo-blow fuse for electrical overload protection. N POWER OUTPUT mA NL/FL = 0.2% Ripple = 8MV Full Load The output is short circuit protected for momentary shorts. However, a sustained short circuit may damage or burn-out the power supply. PHYSICAL DIMENSIONS 2.375(W) x 1.75(D) x 3.00(H), base to top of LED 2006 Essex Engineering Corp. All Rights Reserved. Printed in U.S.A. Pub. No , Rev. 0

27

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000. INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3 M336 Rev F November 21, 2000 ÇConsilium Consilium US, Inc. 59 Porter Rd Littleton, MA 01460-1431 USA

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL MYRIAD TPC VISIT OUR WEBSITE SIGMACONTROLS.COM MYRIADI&O062705 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING 7,8

More information

Pioneer-R16 Gas Monitor Operator s Manual

Pioneer-R16 Gas Monitor Operator s Manual Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas

More information

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail Manufacturers of Process Controls and Instrumentation Instruction Manual Model: Function: Input: PCS-400-XY Pump Controller X=2: 4-20 ma X=5: 1-5 VDC X=6: 0-10 VDC X=7: Output: Power: 4 Pump Control Relays

More information

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER PNEUMERCATOR Liquid Level Control Systems Electronic Systems Excluding LC2000 And TMS Series MAINTENANCE & TROUBLESHOOTING GUIDE 400 300 500 FUEL LEVEL LEAK MONITOR 1 200 600 OIL/GAS NORMAL WATER PNEUMERCATOR

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas User s Manual TIGER S EYE E-Series Mark V Jockey TIGERFLOW Systems, Inc. 4034 Mint Way Dallas, Texas 75237 214-337-8780 www.tigerflow.com TABLE OF CONTENTS Introduction... 4 Sequence of Operation... 5

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

OPERATION & MAINTENANCE MANUAL GUARDIAN SPACE PRESSURE MONITOR WITH REMOTE AUXILLARY ALARM

OPERATION & MAINTENANCE MANUAL GUARDIAN SPACE PRESSURE MONITOR WITH REMOTE AUXILLARY ALARM OPERATION & MAINTENANCE MANUAL GUARDIAN SPACE PRESSURE MONITOR WITH REMOTE AUXILLARY ALARM PARAGON CONTROLS INCORPORATED P.O. BOX 99 FORESTVILLE, CALIFORNIA 95436-0099 (707) 579-1424 /SPM REV. 7, 7/24/09

More information

Model A1600 Series Annunciator

Model A1600 Series Annunciator Seekirk Model A1600 Series Annunciator Applications: For usage in all types of process industries, electric generation, transmission and distribution, gas and water utilities. Features: The Seekirk model

More information

PRYCO, INC. FUEL CONTROL

PRYCO, INC. FUEL CONTROL PRYCO, INC. FUEL CONTROL and MONITORING SYSTEM Page 1 DETAIL SPECIFICATIONS INTRODUCTION PRYCO s FUEL CONTROL and MONITORING (FCM) system is the most sophisticated and powerful control tool available for

More information

E340 BOILER CONTROL INSTALLATION MANUAL

E340 BOILER CONTROL INSTALLATION MANUAL E-3451 JUNE 1999 E340 BOILER CONTROL INSTALLATION MANUAL DESCRIPTION The E340 Boiler Room Control is a microprocessor-based Boiler Management System designed to interface with existing Fireye D Series

More information

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual From urgent alarms to routine messages, the PD141AFO VIGILANTE handles all types of operational messages with simplicity and economy. The VIGILANTE

More information

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary

More information

ACCURATE ELECTRONICS INC

ACCURATE ELECTRONICS INC ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A

More information

7EF/7HF/7EC/7ES Temperature Controllers

7EF/7HF/7EC/7ES Temperature Controllers 7EF/7HF/7E/7ES Temperature ontrollers Dual 4 Digit LED Display Universal Input (6 T/, RTD, mv, V, ma) Autotuning NEMA 4X 100 to 240 Vac Switching Power Supply Algorithms for Heat or Heat/ool ontrol 2 Independent

More information

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual PD154 & PD158 VIGILANTE II ANNUNCIATORS 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal Power

More information

OVEN INDUSTRIES, INC.

OVEN INDUSTRIES, INC. OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and

More information

GasSens. Hydrogen Peroxide Monitor. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

GasSens. Hydrogen Peroxide Monitor. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park GasSens Hydrogen Peroxide Monitor Home Office European Office Analytical Technology, Inc. ATI (UK) Limited 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park Collegeville, PA 19426 Delph New Road, Delph

More information

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX BACKUP PUMP CONTROL SYSTEM MODEL NUMBER BPC-3 November 22, 1999 Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA 01460-1431 USA Telephone:

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

Pump-Down Controller MODEL 4052

Pump-Down Controller MODEL 4052 Pump-Down Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4052 Pump-Down

More information

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B PRODUCT BULLETIN SB 8001B Type 8001 ALARM ANNUNCIATOR TYPE8001 FEATURES 16 or 32 alarm points per flush mount enclosure Displays are backlit with long life LEDs and engraved to suit Dimmer controls built

More information

4 & 8-POINT ANNUNCIATORS Instruction Manual

4 & 8-POINT ANNUNCIATORS Instruction Manual 4 & 8-POINT ANNUNCIATORS Instruction Manual 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal

More information

ESP TECHNOLOGIES LIMITED

ESP TECHNOLOGIES LIMITED Alarm Technology ESPAN-01 Series Annunciator System Combination type User Manual (Rev. 1) ESP TECHNOLOGIES LIMITED www.esptechno.com Content Page Introduction 2 General Description 2 Overview - Annunciator

More information

Speed and Frequency Seite 1 von 7

Speed and Frequency Seite 1 von 7 Speed and Frequency Seite 1 von 7 E16 Systems for High Safety Speed ing, all with Triple Modular Redundancy. A choice of versions to meet various demands. Compliant with SIL3 / IEC 61508 and/or API 670.

More information

B-40/B-41 Modulating Temperature Controller

B-40/B-41 Modulating Temperature Controller INSTALLATION & OPERATING INSTRUCTIONS B-40/B-41 Modulating Temperature Controller For Raytherm Boilers & Water Heaters H2 514-4001 WH2 2100-4001 Catalog No. 5000.70 Effective: 12-21-11 Replaces: NEW P/N

More information

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G E SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF DATE: 11/13/06 2/1/07 1 Copyright, E, Inc. E 1. ENERAL...4 1.1 Scope Of Work... 4 1.2 Codes and Standards... 4 2. PRODUCTS...5

More information

MODEL 5100 VOTING LOGIC MODULE

MODEL 5100 VOTING LOGIC MODULE DESCRIPTION DESCRIPTION The SST Model 5100 Multi-Input Voting Logic Module is used to monitor the status of up to 14 different points in a hazard zone, and report when a selectable number of these points

More information

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7 MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7 VISIT OUR WEBSITE SIGMACONTROLS.COM MYRIAD DPC MANUAL 013114 1 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features

More information

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4 Table of Contents Page Quick Set-up Instructions 1 Theory of Operation 2 Specifications 3 TM 1003W Controls and Connections 4 1. Power Source Connector 5 2. Alarm Output Connector 5 3. Variation Detection

More information

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804 #4202 2 amp #4204 4 amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL 4202/4MA, Rev. E 0804 4202/4204 Power Supply Fused 115 V Input Low Battery Indicator DC Output Adjustable 0.7 to 3.7 Volts from nominal

More information

Oxygen (O2) Single-Point Gas Detection System

Oxygen (O2) Single-Point Gas Detection System Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity

More information

DGC-1000 DIGITAL GENSET CONTROLLER

DGC-1000 DIGITAL GENSET CONTROLLER DGC-1000 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-1000) offers a low cost microprocessor based integrated alternative for small to medium sized genset control and monitoring.

More information

Nov 08 PRODUCT SPECIFICATION SHEET

Nov 08 PRODUCT SPECIFICATION SHEET Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 Nov 08 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

D3000. Installation & Setup Guide

D3000. Installation & Setup Guide Page 1 of 15 17483-00 Rev B s1 April 2009 Contents Description Page Safety... 3 Installation Standards 3 Specification. 3-4 Circuit Board Connection 5 Mounting Dimensions 6 Installation Procedure 6 Mechanical

More information

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05 Sierra Model 951 Digital Flo-Box Instruction Manual Part Number IM-951 Revision A 09-05 5 Harris Court, Building L Monterey, CA 93940 (831) 373-0200 (800) 866-0200 Fax (831) 373-4402 www.sierrainstruments.com

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information

I/A Series 716C 1/16 DIN Temperature Controller

I/A Series 716C 1/16 DIN Temperature Controller Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

Model A1700 Series Annunciator

Model A1700 Series Annunciator Seekirk Model A1700 Series Annunciator Applications: For usage in all types of process industries, electric generation, transmission and distribution, gas and water utilities. Features: The Seekirk model

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

Pump-Up Controller MODEL 4062

Pump-Up Controller MODEL 4062 Pump-Up Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4062 Pump-Up

More information

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL MADE IN THE U.S.A. U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION SERIAL NUMBER The Cookson Company FIREFLY II PLUS Time Delay Release

More information

1 INTRODUCTION SYSTEM DESCRIPTION... 3

1 INTRODUCTION SYSTEM DESCRIPTION... 3 1 INTRODUCTION... 1 2 SYSTEM DESCRIPTION... 3 3 INSTALLATION... 5 3.1 INPUT/OUTPUT POSITIONING... 5 3.2 CONTROLLER WIRING... 6 3.2.1 Dual Fuel... 6 Single Fuel... 7 3.3 BUILT-IN ANALOG INPUTS...8 4 GENERAL

More information

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03 Digital Controller A 96 x 96-mm (DIN) Digital Process Controller Optimum PID control with feed-forward control circuitry. High accuracy (+0.3% FS +1 digit max.). Replaceable Output Units. Models with communications

More information

STATUS ALARM HISTORY ALARM RESET

STATUS ALARM HISTORY ALARM RESET Instruction Manual Model 1582-42L Data Switch February 1999, Rev 0 CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 ONLINE SWITCH RESET MAN

More information

EC Series Wall Unit Humidifier

EC Series Wall Unit Humidifier Read and Save These Instructions EC Series Wall Unit Humidifier Controller Operation Manual SEASONAL DRAIN SAFETY CIRCUIT OPEN POWER FILL VALVE OPEN WATER LEVEL FULL COOL DOWN CYCLE DRAIN VALVE OPEN HEATER

More information

Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE

Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE Integrated Gas Control Valve with Integral Controller The Series 70CV3000 Chloromatic Intelligent Gas Flow Control Valve is designed to control chemical

More information

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual This manual covers operation of the tcm100 and tcm101 Series Temperature Control Modules.

More information

Operational Overview and Controls Guide

Operational Overview and Controls Guide DOCUMENT: ECSEQ2-2 EFFECTIVE: 02/26/10 SUPERSEDES: 02/14/07 Operational Overview and Controls Guide Standard Two or Three Pump Type VFD Booster Controls 6700 Best Friend Road. Norcross, GA 30071. (770)

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS... SECTION Table of Contents SECTION 1 INTRODUCTION...................... 1.1 Description............................... 1.2 Features................................. 1.3 Models..................................

More information

Technical Manual. Level Alarm Unit CARLA & WIDS

Technical Manual. Level Alarm Unit CARLA & WIDS CARLA & WIDS Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual CARLA for Tankers Cargo Tanks

More information

Sierra Series 900 Single & Dual Channel System. Instruction Manual

Sierra Series 900 Single & Dual Channel System. Instruction Manual Series 240/24 Instruction Manual Table of Contents Sierra Series 900 Single & Dual Channel System Instruction Manual Part Number IM-90-07/05 Revision D. 5 Harris Court, Building L Monterey, CA 93940 (83)

More information

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08 Beacon 200 Gas Monitor Operator s Manual Part Number: 71-2102RK Released: 6/6/08 Table of Contents Chapter 1: Introduction.................................................3 Overview.............................................................3

More information

RTD TEMPERATURE SENSING SYSTEM

RTD TEMPERATURE SENSING SYSTEM General Overview RTD TEMPERATURE SENSING SYSTEM The Prime Technology RTD Temperature System 9219-00-0002 is a three-channel temperature measuring system that utilizes two RTD Temperature Sensor inputs

More information

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input SCR/SCRF SERIES FLOAT BATTERY CHARGERS Industry s First Choice for Time-Tested Proven Reliability Single-Phase Input Three-Phase Input Applications for: Utility & General Industry Switchgear Engine starting

More information

CP CP

CP CP CP-8161-333 CP-8161-433 Electronic Programmable Controller Six Stage, Dual Setpoint General Instructions APPLICATION Electronic six stage programmable controller with proportional output for heating, cooling

More information

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK Analox 1000 Series User Manual Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK T: +44 (0)1642 711400 F: +44 (0)1642 713900 W: www.analox.net E: info@analox.net

More information

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES USER INSTRUCTIONS FOR THE CHEMGARD INFRARED GAS MONITOR SERIES To completely customize the specification to your exact application, modification to the

More information

Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2

Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2 The Custom Controls Solution Provider Hydromatic has a reputation for providing dependable submersible pumps for wastewater lift stations and has continually raised the bar for quality products and customer

More information

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS OPERATES ON 12 OR 24 VOLTS AC/DC, AUTO VOLTAGE SENSING FULLY PROGRAMMABLE FROM THE KEYPAD

More information

www.severntrentservices.com CAPITAL CONTROLS Series 70CV3000 Chloromatic TM Intelligent Gas Flow Control Valve The Series 70CV3000 Chloromatic TM Intelligent Gas Flow Control Valve is designed to control

More information

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 4/01 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1000 and UDC1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08 GasScanner 4C Four Channel Monitor Operator s Manual MINT-0280-XX Rev. A 02/25/08 Product Warranty Matheson Tri-Gas., warrants gas alarm equipment sold by us to be free from defects in materials, workmanship,

More information

Instructions Oxygen Controller R8471C 2.1 8/

Instructions Oxygen Controller R8471C 2.1 8/ Instructions 95-8405 Oxygen Controller R8471C 8/07 95-8405 Table Of Contents Section I - General Information APPLICATION...1 FEATURES...1 DESCRIPTION...1 SPECIFICATIONS...2 Controller...2 C7052C O2 Detector...2

More information

Model 4001 Series Single Channel Controller

Model 4001 Series Single Channel Controller Model 4001 Series Single Channel Controller Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 (800) 727-4377 (408) 262-9042 - Fax E-Mail: sales@sierramonitor.com Web site:

More information

FLOAT BATTERY CHARGERS

FLOAT BATTERY CHARGERS FLOAT BATTERY CHARGERS UNFILTERED SCR SERIES FILTERED SCRF SERIES SINGLE PHASE INPUT THREE PHASE INPUT Applications for: UTILITY & GENERAL INDUSTRY Switchgear Engine Starting Emergency Lighting Alarm Systems

More information

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A GasScanner 1C Single Channel Monitor Operator s Manual MINT-0278-XX Rev A Product Warranty Matheson Tri-Gas, Inc., warrants gas alarm equipment sold by us to be free from defects in materials, workmanship,

More information

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670 Bulletin AV-670 Series 670 Hood Monitor Specifications - Installation and Operating Instructions DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Phone: 219/879-8000 Fax: 219/872-9057

More information

Reciprocating Chiller

Reciprocating Chiller HVAC PRO for Windows User s Manual 637.5 OEM Section Technical Bulletin Issue Date 1094 Reciprocating Chiller Reciprocating Chiller Page 3 Description 3 Theory of Operation 5 Overview 5 Control Sequence

More information

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR OM117 OPERATING AND MAINTENANCE MANUAL for the G30 CARBON DIOXIDE MONITOR (Part No: G30) (Intentionally Blank) APPROVAL SHEET DIVEX MANUAL NUMBER: ADVITIUM NUMBER: DOCUMENT TITLE: OM117 GA-OM-5715 G30

More information

AIS750 Series Alarm Annunciator

AIS750 Series Alarm Annunciator Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

Beacon 800 Gas Monitor Operator s Manual

Beacon 800 Gas Monitor Operator s Manual Beacon 800 Gas Monitor Operator s Manual Part Number: 71-0037RK Revision: F Released: 4/18/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be

More information

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA 99336 www.jmcvr.com 1-509-586-9893 Table of Contents TABLE OF FIGURES...1 OVERVIEW OF THE HRC CAPABILITIES...2 INSTALLATION AND

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING FOR OPERATION FROM 115 AC POWER Andersen Medical Gas 12 Place Lafitte Madisonville, LA 70447 http://www.themedicalgas.com 1-866-288-3783

More information

S AFETY SYSTEMS TECHNOLOGY Mill Creek Drive, Suite 215 Laguna Hills, California 92653, USA Tel (949) Fax (909)

S AFETY SYSTEMS TECHNOLOGY Mill Creek Drive, Suite 215 Laguna Hills, California 92653, USA Tel (949) Fax (909) DESIGN MANUAL Model GIR911 Infrared Carbon Dioxide NOVA-Sensor 70071 The information in this document is applicable to sensors built on or after October, 2001 The information and technical data disclosed

More information

MODEL B2 INSTALLATION MANUAL

MODEL B2 INSTALLATION MANUAL RELEASE DEVICES GENERAL DESCRIPTION MODEL B2 INSTALLATION MANUAL S/N: The B2 Series Time Delay Release Devices are UL Listed, Canadian Listed, and CSFM Listed for use on rolling doors, single-slide and

More information

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

THE SS90 SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL S S S S S S S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED U 99Y9 RESET L RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

Model 96VTR ¼ DIN Process Controller

Model 96VTR ¼ DIN Process Controller 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 96VTR Product Info Page INSTRUCTION MANUAL Model 96VTR ¼ DIN

More information

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector) SMAC Controller Industrial Lubrication Systems Operation The SMAC Controller is a multi-purpose programmable controller used with industrial lubrication systems. Controller settings are saved whenever

More information

INTRODUCTION / TABLE OF CONTENTS

INTRODUCTION / TABLE OF CONTENTS 1 2 INTRODUCTI / TABLE OF CTENTS Step One The LVCN 51 Series Continuous Relay Controller is a general purpose level controller which provides single tank level indication with dual relays and a repeater

More information

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX Page 1 of 10 Model 10807800 January 2014 ACCURATE ELECTRONICS INC PO BOX 1654 97075-1654 8687 SW HALL BLVD 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 WWW.ACCURATE.ORG Practice Section 10807800

More information

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0 CFP-105 Fire Alarm Control Panel Installation Manual Version 1.0 WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability

More information

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-3 ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS Features: For use with doors or groups of doors that must interlock with each other to regulate control of accessing one area from another,

More information

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/ Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/08 Table Of Contents Section I Installation and Startup.................. 1 INSTALLATION............................................

More information

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd. F-2000 PC and AO OUTPUT BOARDS INSTRUCTION MANUAL Blue-White R Industries, Ltd. 500 Business Drive Huntington Beach, CA 92649 USA Phone: 714-89-8529 FAX: 714-894-9492 E mail: sales@blue-white.com or techsupport@blue-white.com

More information

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4 HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4 INTRODUCTION Thank you for purchasing the Hokkim Integrated Automatic Mains Failure Control Board model HAMF- 8 or HAMF-4. We shall

More information

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input April 2006 SCR-SCRF Utility & General Industry Switchgear Alarm Systems Engine Starting Railroad Emergency

More information

Unit 3 Machine Composition

Unit 3 Machine Composition Unit 3 Machine Composition Unit Objectives Given a realistic scenario in which the learner has access to the machine s internal components the learner will understand the composition and functions of the

More information

M1000 Alarm Annunciator

M1000 Alarm Annunciator Data Sheet Alarm Annunciator Reliable Supervision and Control 10 inputs with LED indications Supports both NO/NC input contacts 10 open collector outputs Built-in siren relay Text label for alarm descriptions

More information

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation PS6 SERIES Power Supplies PS6 SERIES Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation and Specifications Manual ISDPS6_SERIES 08121590 PCN15016 R05/15GR

More information

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1 Pump Logic User Manual CB-1000 P/N ILK-CB1000-1 STATEMENT OF LIMITED WARRANTY The limited warranty applicable to this product is set forth in USFilter Control Systems standard terms of sale that are made

More information

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels CF5000, MF5000 and FXP5000 Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels 16 zone panels Contents PANEL INSTALLATION...3 Installation...3 PANEL WIRING... 3 Mains power

More information

Table of Contents SECTION PAGE

Table of Contents SECTION PAGE Table of Contents SECTION PAGE SECTION 1 INTRODUCTION................... 1.1 Description.............................. 1.2 Features................................ 1.3 Models.................................

More information