Radon Test Results, Prentis II Apartments, West 10 Mile Road, Oak Park, Michigan (ASTI Project No )

Size: px
Start display at page:

Download "Radon Test Results, Prentis II Apartments, West 10 Mile Road, Oak Park, Michigan (ASTI Project No )"

Transcription

1 Investigation Remediation Citation Drive, Suite 100 Compliance Restoration Brighton, MI ASTI Fax: February 6, 2017 Ms. Nancy Heinrich Prentis II JSL LDHA LP West Ten Mile Road Oak Park, Michigan RE: Radon Test Results, Prentis II Apartments, West 10 Mile Road, Oak Park, Michigan (ASTI Project No ) Dear Ms. Heinrich: ASTI Environmental (ASTI) was retained by Prentis II JSL LDHA LP to complete radon testing for the above referenced property (Property). Radon testing was conducted with regard to securing a US Department of Housing and Urban Development (HUD) 223(f) FHA loan. The testing was conducted in accordance with HUD Notice guidelines, and the American Association of Radon Scientists and Technologists (AARST), ANSI/MAMF-2012, Protocol for Conducting Radon and Radon Decay Product Measurements in Multifamily Buildings. ASTI acknowledges that Prentis II JSL LDHA LP, Red Capital, and HUD may rely upon this letter and its conclusions. The Property is located at the above referenced address in Oak Park, Michigan, which is located in EPA Radon Zone 2. The Property includes one 6-story apartment building with 11 ground-contact residential units. Previous radon testing was completed in 2013 at the Property and one radon mitigation system was installed to address elevated concentrations of radon previously detected in Unit 124. Testing was conducted in all ground-contact residential units (11) and 10% of the upper floor units (9) during the period of January 19 through January 23, In addition, quality control measurements included 10% (2) duplicates and 5% (1) blanks. One Air-Chek Foil Bag Test Kit (AC/NRSB Device Code 10333) was placed in each of the ground-contact residential units and selected upper floor units. Each test kit was placed at breathing level, approximately 5-6 feet above the floor. In addition, two duplicate test kits and one blank were also placed and analyzed. A table summarizing the testing results is attached (Attachment A). Radon laboratory analytical results were below the EPA Action Level of 4.0 pci/l at all, but one of the locations tested. A radon concentration was detected at 4.6 pci/l in Unit 137. The laboratory reports provided by Air-Chek can be found in Attachment B. Based on the results of the testing at the Property, it appears that the concentrations of radon entering the units are minimal with the exception of Unit 137. ASTI recommends that additional testing be performed in Unit 137 to identify if mitigation is necessary. Another option is to

2 proceed directly to radon mitigation in order to address the elevated concentration detected in Unit 137. If I may be of any further assistance in this matter, please contact me at (800) Sincerely, ASTI Environmental Penelope Beamer Property Services Group Radon Measurement Specialist NRSB Certification No. 15SS012 Attachments A B C Table Radon Test Results Laboratory Analysis Reports Radon Certification Prentis II Radon Testing ASTI Project

3 Attachment A Table Radon Test Results Prentis II Radon Testing ASTI Project

4 Unit Tested Floor Tested Radon Test Results Prentis II Apartments Oak Park, Michigan ASTI Project No Dates Sampled Start Date End Date (pci/l) Test Results Variance (±pci/l) Blank 1 1 1/19/2017 1/23/2017 < /19/2017 1/23/ a 1 1/19/2017 1/23/ b 1 1/19/2017 1/23/ /19/2017 1/23/ /19/2017 1/23/ /19/2017 1/23/ /19/2017 1/23/ /19/2017 1/23/ /19/2017 1/23/ a 1 1/19/2017 1/23/ b 1 1/19/2017 1/23/ /19/2017 1/23/ /19/2017 1/23/ /19/2017 1/23/2017 < /19/2017 1/23/2017 < /19/2017 1/23/ /19/2017 1/23/ /19/2017 1/23/ /19/2017 1/23/2017 < /19/2017 1/23/2017 < /19/2017 1/23/2017 < /19/2017 1/23/ Bolded & shaded values indicate results equal to or greater than the EPA Action Level of 4.0 pci/l. -Samples ending in -a & -b indicate duplicate samples placed side by side

5 Attachment B Laboratory Analysis Reports Prentis II Radon Testing ASTI Project

6 January 25, 2017 ** LABORATORY ANALYSIS REPORT ** Radon test result report for: PRENTIS II W. 10 MILE RD. Kit # Room Id Started Ended pci/l Analyzed :00 am 9:00 am < :00 am 9:00 am 2.5 ± :00 am 9:00 am 0.9 ± :00 am 9:00 am 1.2 ± :00 am 9:00 am 0.6 ± :00 am 9:00 am 0.8 ± :00 am 9:00 am 2.4 ± :00 am 9:00 am 1.7 ± :00 am 9:00 am 1.0 ± :00 am 9:00 am 2.8 ± :00 am 9:00 am 2.2 ± :00 am 9:00 am 2.5 ± :00 am 9:00 am 4.6 ± :00 am 9:00 am 3.1 ± :00 am 9:00 am < :00 am 9:00 am < :00 am 9:00 am 0.7 ± :00 am 9:00 am 0.6 ± :00 am 9:00 am 1.1 ± :00 am 9:00 am < :00 am 9:00 am < :00 am 9:00 am < :00 am 9:00 am 0.6 ± Air Chek, Inc Butler Bridge Rd, Mills River, NC Phone: (828) Fax: (828)

7 Attachment C Radon Certification Prentis II Radon Testing ASTI Project

8

Environmental Resources Group, LLC (ERG) has completed the Radon Testing for the referenced property in Ann Arbor, Michigan.

Environmental Resources Group, LLC (ERG) has completed the Radon Testing for the referenced property in Ann Arbor, Michigan. August 8, 2013 Mr. Richard Higgins Norstar Development USA, L.P. 733 Broadway Albany, New York 12207 Re: Radon Testing Green Baxter 1737 Green Road, Ann Arbor, Michigan ERG Project 1127.004 Dear Mr. Higgins,

More information

RADON SCREENING SURVEY FOLLOW-UP WHITTIER WOODS CENTER Whittier Boulevard, Bethesda, Maryland 20817

RADON SCREENING SURVEY FOLLOW-UP WHITTIER WOODS CENTER Whittier Boulevard, Bethesda, Maryland 20817 RADON SCREENING SURVEY FOLLOW-UP WHITTIER WOODS CENTER 7100 Whittier Boulevard, Bethesda, Maryland 20817 EXECUTIVE SUMMARY Date of Test Report: 5/12/16 Round of Testing: Initial Follow-up Post Remediation

More information

RADON SCREENING SURVEY FOLLOW-UP CONCORD CENTER Hidden Creek Rd, Bethesda, Maryland 20817

RADON SCREENING SURVEY FOLLOW-UP CONCORD CENTER Hidden Creek Rd, Bethesda, Maryland 20817 RADON SCREENING SURVEY FOLLOW-UP CONCORD CENTER 7210 Hidden Creek Rd, Bethesda, Maryland 20817 EXECUTIVE SUMMARY Date of Test Report: 3/31/16 Follow-Up Round of Testing: Initial Follow-up Post Remediation

More information

Woodlin Elementary School Date of Report March 14, 2018

Woodlin Elementary School Date of Report March 14, 2018 MCPS RADON TESTING - EXECUTIVE SUMMARY Site Name Woodlin Elementary School Date of Report March 14, 2018 Round of Testing Initial Follow-up Post Remediation 2 year testing 5 year testing HVAC Upgrade Window

More information

RADON SCREENING SURVEY FOLLOW-UP GREAT SENECA CREEK ELEMENTARY SCHOOL Dairymaid Drive, Germantown, Maryland 20874

RADON SCREENING SURVEY FOLLOW-UP GREAT SENECA CREEK ELEMENTARY SCHOOL Dairymaid Drive, Germantown, Maryland 20874 RADON SCREENING SURVEY FOLLOW-UP GREAT SENECA CREEK ELEMENTARY SCHOOL 13010 Dairymaid Drive, Germantown, Maryland 20874 EXECUTIVE SUMMARY Date of Test Report: 3/31/16 Follow-Up Round of Testing: Initial

More information

MCPS RADON TESTING. Executive Summary: Festival Center. Date of Test Report: 4/15/2016 Round of Testing: Initial Follow-up Post Remediation

MCPS RADON TESTING. Executive Summary: Festival Center. Date of Test Report: 4/15/2016 Round of Testing: Initial Follow-up Post Remediation E NGINEERS P LANNERS S CIENTISTS C ONSTRUCTION M ANAGERS 936 RIDGEBROOK ROAD SPARKS, MD 21152 410-316-7800 (FAX) 410-316-7935 MCPS RADON TESTING Executive Summary: Festival Center Date of Test Report:

More information

Radon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For: Radon Measurement Survey Report Site:July 5, 2018 1200 Front Street Aurora, Illinois 60505 Survey Dates: May 9, 2018 thru May 11, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora,

More information

Comprehensive Short-Term Radon Survey Report

Comprehensive Short-Term Radon Survey Report Environmental Works, LLC 2634 SE Steele St. Portland, OR. 97202 Phone: 503-719-6715 Fax: 503-972-1866 Email: Sebastian@eworksnw.com Comprehensive Short-Term Radon Survey Report Test Performed At: Trillium

More information

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 417 Fifth Street Aurora, Illinois 60505 Survey Dates: May 9, 2018 thru May 11, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

Radon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 240 Melrose Avenue Aurora, Illinois 60505 Survey Dates: May 1, 2018 thru May 3, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

HUD Radon Updates. April 19, 2017

HUD Radon Updates. April 19, 2017 HUD Radon Updates April 19, 2017 Radon Testing Standards HUD requires following the most recent version of the ANSI AARST standards for testing: MAMF 2017 (released 3/1/17) Multifamily Buildings standard

More information

Radon Measurement Survey Report. Rollins Elementary School 950 Kane Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Rollins Elementary School 950 Kane Street Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 950 Kane Street Aurora, Illinois 60505 Survey Dates: May 15, 2018 thru May 18, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

Radon Measurement Survey Report. Waldo Middle School 56 Jackson Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Waldo Middle School 56 Jackson Street Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 56 Jackson Street Aurora, Illinois 60505 Survey Dates: May 8, 2018 thru May 10, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

Radon Measurement Survey Report. Fred Rodgers Magnet Academy 501 College Avenue Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Fred Rodgers Magnet Academy 501 College Avenue Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 501 College Avenue Aurora, Illinois 60505 Survey Dates: May 16, 2018 thru May 18, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points Topic 4 - Audio 46 Key Points : Measures taken to increase confidence in results. Quality Assurance: Program that assures that measures are being done and in a timely manner. Precision: How close measurements

More information

INDOOR RADON POLICY AND PROCEDURES LAWLER WOOD HOUSING, LLC

INDOOR RADON POLICY AND PROCEDURES LAWLER WOOD HOUSING, LLC INDOOR RADON POLICY AND PROCEDURES LAWLER WOOD HOUSING, LLC Prepared for Lawler-Wood Housing, LLC Riverview Tower, Suite 2000 900 South Gay Street Knoxville, Tennessee Prepared by ORION Orion Environmental

More information

Special Attention of: Notice H All Multifamily Hub Directors All Program Center Directors All Project Managers All Field Office Directors

Special Attention of: Notice H All Multifamily Hub Directors All Program Center Directors All Project Managers All Field Office Directors U.S. DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT WASHINGTON, DC 20410-8000 ASSISTANT SECRETARY FOR HOUSING- FEDERAL HOUSING COMMISSIONER Special Attention of: Notice H 2013-03 All Multifamily Hub Directors

More information

Conducting and Assessing Radon Surveys in Schools & Commercial Buildings

Conducting and Assessing Radon Surveys in Schools & Commercial Buildings Conducting and Assessing Radon Surveys in Schools & Commercial Buildings CIHC 2015 Annual Conference December 7, 2015 Gustavo A. Delgado, Ph.D. California Radon Measurement Provider Forensic Analytical

More information

RADON SCREENING SURVEY FOLLOW-UP SPRINGBROOK HIGH SCHOOL

RADON SCREENING SURVEY FOLLOW-UP SPRINGBROOK HIGH SCHOOL RADON SCREENING SURVEY OLLOW-UP SPRINGBROOK HIGH SCHOOL, Silver Spring, Maryland 20904 EXECUTIVE SUMMARY Date of Test Report: 9 ebruary 2016 Round of Testing: Initial ollow-up Post Remediation # rooms

More information

Radon Program Going Forward

Radon Program Going Forward American Association of Radon Scientists and Technologists Radon Program Going Forward Shawn Price President AARST Initiatives Reinstatement of State Indoor Radon Grants EPA FRAP & NRAP Leadership Partner

More information

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date: LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: ALPHA TRACK Method Number: ELAP method number 7035 SOP Number: Revision Number: SOP Date: Personnel / Data Records observed: Page 1 of 6 RADON IN AIR

More information

ALL RADON TESTS WERE SIGNIFICANLY BELOW

ALL RADON TESTS WERE SIGNIFICANLY BELOW Radon Testing Results for Multifily Radon Testing 4pCi/L and above is considered an action level At this time, radon levels at tested locations were considered low and safe for this building. ALL RADON

More information

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date: LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: ELECTRET by Voltametry Method Number: ELAP method number 7034 SOP Number: Revision Number: SOP Date: Personnel / Data Records observed: General LLD:

More information

Multnomah Education Service District

Multnomah Education Service District Cascade Radon, Inc. 12839 NE Airport Way Bldg.9 Testing, Mitigation, Portland, Oregon 97230 Systems Design Phone: (503) 421-4813 CCB 180537 / CASCARI927C1 Fax: (503) 281-6170 Office@CascadeRadon.com Radon

More information

RADON PLAN. Eugene School District 4J Facilities Management 715 West Fourth Avenue Eugene, OR

RADON PLAN. Eugene School District 4J Facilities Management 715 West Fourth Avenue Eugene, OR RADON PLAN The 2015 Legislature passed House Bill (HB) 2931 so that if elevated radon levels in Oregon schools existed they would be known. House Bill 2931 later became Oregon Revised Statute (ORS) 332.166-167.

More information

Imagine the result. Dear Ms. Vanderlaan:

Imagine the result. Dear Ms. Vanderlaan: Mary Vanderlaan Supervisor, Lansing District Michigan Department of Environmental Quality Water Resources Division 525 W. Allegan (Constitution Hall, 4N) P. O. Box 30242 Lansing, MI 48909-7742 ARCADIS

More information

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting Method Number: ELAP method number 7036 SOP Number: Revision Number:

More information

Quality Assurance Plan for Conducting Radon Measurements

Quality Assurance Plan for Conducting Radon Measurements Quality Assurance Plan for Conducting Radon Measurements 921 Pheasant Run Lindsborg, Kansas 67456 (785) 510-0000 info@clarityinspect.com getyourinspection.com page 1 of 18 Table of Contents A.1 Approval

More information

Presentation to NC Home Inspectors Licensure Board April 7, Opportunities and Partnerships

Presentation to NC Home Inspectors Licensure Board April 7, Opportunities and Partnerships Presentation to NC Home Inspectors Licensure Board April 7, 2017 Opportunities and Partnerships Radon Basics 2 Radon Basics Radon is the leading environmental cause of lung cancer Source of radon is the

More information

David F. Metzger 121 N. Leavitt Rd. #313, Amherst, OH Certified Radon Tester Ohio License #: RS340 & RC213; NRPP ID#: RT

David F. Metzger 121 N. Leavitt Rd. #313, Amherst, OH Certified Radon Tester Ohio License #: RS340 & RC213; NRPP ID#: RT Contract #: per D. Boyer/ C. Fredrichs for Radon Testing Services Report of Radon Measurement Survey Date: November 16, 2018 Site: Shaker Schools, Shaker Heights, Ohio Onaway Elementary School and Woodbury

More information

Kansas Radon Program Newsletter

Kansas Radon Program Newsletter Kansas Radon Program Newsletter Serving individuals certified in radon measurement, mitigation and laboratory services in Kansas. January 2019 Questions? Let s Talk. Certification Questions Mark Ungerer/

More information

Ohio Department of Health, Bureau of Environmental Health and Radiation Protection, Radon Licensing Program. School Radon Testing Checklist

Ohio Department of Health, Bureau of Environmental Health and Radiation Protection, Radon Licensing Program. School Radon Testing Checklist Ohio Department of Health, Bureau of Environmental Health and Radiation Protection, Radon Licensing Program School Radon Testing Checklist Purpose: This checklist has been prepared to provide school employees

More information

Bethel School District Radon Testing Plan

Bethel School District Radon Testing Plan The 2015 Oregon Legislature passed House Bill (HB) 2931 so that elevated radon levels in Oregon schools would be known. House Bill 2931 later became Oregon Revised Statute (ORS) 332.166-167. As directed

More information

adsw worth Center, New York State Department of Health, Albany, NY 12201

adsw worth Center, New York State Department of Health, Albany, NY 12201 American Association of Radon Scientists and Technologists, Inc. RADON IN NEW YORK STATE'S SCHOOLS Kitto, Michael ly2, Jerry ~ollins~ and Adda ~alamc-~lfie~ adsw worth Center, New York State Department

More information

What you need to know

What you need to know What you need to know What RADON is The health effects How to test your home How to reduce your risk Protect your health. Test your home. www.regionofwaterloo.ca/radon RADON information What is radon?

More information

Measurement Devices. Topic 5 - Audio 56

Measurement Devices. Topic 5 - Audio 56 Topic 5 - Audio 56 Other Classifications Passive devices: Air diffuses in No power required for sampling Active devices: Requires power Pumps air through filter Key Points - Devices What lab sees: Different

More information

Call to Action Reduce Radon s Risk in America

Call to Action Reduce Radon s Risk in America Call to Action Reduce Radon s Risk in America State Policy Action and Laws build a basic foundation for nation-wide progress & innovation in radon risk reduction. 1 RADON -- A RADIOACTIVE GAS IN AS MANY

More information

2.3 Definitions, General Provisions, and Radon Standards

2.3 Definitions, General Provisions, and Radon Standards 216-RICR-50-15-2 TITLE 216 DEPARTMENT OF HEALTH CHAPTER 50 ENVIRONMENTAL HEALTH SUBCHAPTER 15 HEALTHY ENVIRONMENT PART 2 Radon Control 2.1 Authority These regulations are promulgated pursuant to the authority

More information

RULES AND REGULATIONS FOR RADON CONTROL

RULES AND REGULATIONS FOR RADON CONTROL RULES AND REGULATIONS FOR RADON CONTROL [R23-61-RC] STATE OF RHODE ISLAND AND PROVIDENCE PLANTATIONS DEPARTMENT OF HEALTH AUGUST 1994 AS AMENDED January 2002 (re-filing in accordance with the provisions

More information

Radon Testing and Reporting Plan. Tillamook School District #9 Tillamook, Oregon

Radon Testing and Reporting Plan. Tillamook School District #9 Tillamook, Oregon Radon Testing and Reporting Plan Tillamook School District #9 Tillamook, Oregon Introduction: In 2015, the Oregon Legislature passed Oregon Revised Statute (ORS) 332.166-167 which, in part, requires school

More information

AVERAGE RADON CONCENTRATION:

AVERAGE RADON CONCENTRATION: February 2, 2017 Test Number: 1703-142 Property Inspected: 804 425th street, Joice, IA 50446 Licensed Radalink Radon Inspector: Lupkes Inspections Myron and Jayne Lupkes 804 425th Street Joice, IA 50446

More information

835 S. Canyon Blvd., John Day, OR 97845 Phone: (541) 575-1349 Fax: (541) 575-3601 Robert Waltenburg-Superintendent waltenburgr@grantesd.k12.or.us Stacie Holmstrom Deputy Clerk holmstroms@grantesd.k12.or.us

More information

Radon Detection Specialists, Inc. Love the Lungs You re With

Radon Detection Specialists, Inc. Love the Lungs You re With 630-325-4443 800-244-4242 kws@radonresults.com Commercial Radon Survey Report Client: Pleasantdale School District 107 8100 School Street La Grange, Illinois 60525 Survey Date: October 20 2014 to October

More information

Certificate of Completion

Certificate of Completion Love the Lungs You re With 630-325-4443 800-244-4242 Certificate of Completion Every parent or guardian is notified that this facility has performed radon measurements to ensure the health and safety of

More information

(94'*7 $*89 :2 '*7 ((.,$00 *;.3 *89*7'*7, "$ .3.8-*) &8*2 *39-4:78 ! / )+ $*89-&82 * :2! 8&2 51.3,):7&9.43

(94'*7 $*89 :2 '*7 ((.,$00 *;.3 *89*7'*7, $ .3.8-*) &8*2 *39-4:78 ! / )+ $*89-&82 * :2! 8&2 51.3,):7&9.43 (94'*7 $*89 :2 '*7 ((.,$00 0./&026-1/&$2&% )$&-1&% "%"+)-* "%.--1/&$2.0 3)+%)-'-1/&$2).-1 )$("&+ &12&0#&0'.#&+)" 0)4& %#" 3)+%)-' -4)0.-,&-21 )-$)--"2) >HNMF/ 6BU/ *&(")%)",.., *&(",.("'.*.!1&(*) > 6FQNGWFYJI1

More information

EagleRidge High School. Radon Testing Plan

EagleRidge High School. Radon Testing Plan EagleRidge High School Radon Testing Plan The 2015 Legislature passed House Bill (HB) 2931 so that elevated radon levels in Oregon schools would be known. House Bill 2931 later became Oregon Revised Statute

More information

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Commercial Survey Report Client: Community Consolidated School District 181 Site Address: Elm School 6010 S Elm St Hinsdale, IL 60521 Survey Date: April 9, 2012 to April 11, 2012 Initial Test RDS-R-002

More information

PURPOSE. 03/08/18 REVISOR SGS/HR RD The purpose ofparts to is to protect public health by establishing

PURPOSE. 03/08/18 REVISOR SGS/HR RD The purpose ofparts to is to protect public health by establishing 1.1 Department of Health 1.2 Proposed Permanent Rules Relating to Radon Licensing u 4620. 7000 PURPOSE. 1.4 The purpose ofparts 4620.7000 to 4620.7950 is to protect public health by establishing 1.5 licensing

More information

AVERAGE RADON CONCENTRATION: Test has met minimum EPA sampling duration.

AVERAGE RADON CONCENTRATION: Test has met minimum EPA sampling duration. February 5, 2016 Test Number: 8401-12 Property Inspected: 623 Pine St, Macon, GA 31201 Licensed Radalink Radon Inspector: Test performed for: ACME Home Inspections William Jacobs John Harwell 943 Spring

More information

Property Inspected: 623 Pine St, Macon, GA 31201

Property Inspected: 623 Pine St, Macon, GA 31201 February 5, 2016 Test Number: 8401-12 Property Inspected: 6 Pine St, Licensed Radalink Radon Inspector: ACME Home Inspections John Harwell 994 Magnolia St Phone: Fax: 770 555 1944 770 555 2105 Calibrated:

More information

WORKING. TOGETHER to PREVENT LUNG CANCER. A Guide to help you with testing your Child Care Centre for Radon

WORKING. TOGETHER to PREVENT LUNG CANCER. A Guide to help you with testing your Child Care Centre for Radon WORKING TOGETHER to PREVENT LUNG CANCER A Guide to help you with testing your Child Care Centre for Radon GENERAL INFORMATION The purpose of this document is to provide certified radon professionals and

More information

WATER QUALITY TESTING FOR SCHAUMBURG COMMUNITY CONSOLIDATED SCHOOL DISTRICT 54 HOOVER SCHAUMBURG, ILLINOIS OCTOBER 3, 2017 PROJECT NUMBER:

WATER QUALITY TESTING FOR SCHAUMBURG COMMUNITY CONSOLIDATED SCHOOL DISTRICT 54 HOOVER SCHAUMBURG, ILLINOIS OCTOBER 3, 2017 PROJECT NUMBER: WATER QUALITY TESTING FOR SCHAUMBURG COMMUNITY CONSOLIDATED SCHOOL DISTRICT 54 HOOVER SCHAUMBURG, ILLINOIS OCTOBER 3, 2017 PROJECT NUMBER: 17-18350 1550 Hubbard Ave., Batavia, IL 60510, 630-879-3006 Schaumburg

More information

Illinois School District & Daycares

Illinois School District & Daycares Illinois School District & Daycares Commercial Radon Test Final Measurement Report Radon Measurements of: OAK CREST ELEMENTARY SCHOOL LOCATED IN BEACH PARK, IL 38550 N. LEWIS AVE. BEACH PARK, IL 60099

More information

Certificate of Completion

Certificate of Completion Love the Lungs You re With 630-325-4443 800-244-4242 Certificate of Completion Every parent or guardian is notified that this facility has performed radon measurements to ensure the health and safety of

More information

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Commercial Radon Survey Report Client: Community Consolidated School District 181 Site Address: Walker School 120 S Walker Clarendon Hills, IL 60514 Survey Date: April 25, 2012 to April 27, 2012 Initial

More information

radon Keeping your home safe from radon

radon Keeping your home safe from radon radon Keeping your home safe from radon What is radon? Radon is a colorless and odorless gas that comes from the soil. The gas can accumulate in the air we breathe. Radon gas decays into fine particles

More information

CLACKAMAS EDUCATION SERVICE DISTRICT HEALTHY AND SAFE SCHOOLS PLAN

CLACKAMAS EDUCATION SERVICE DISTRICT HEALTHY AND SAFE SCHOOLS PLAN CLACKAMAS EDUCATION SERVICE DISTRICT HEALTHY AND SAFE SCHOOLS PLAN March 17, 2017 Introduction Clackamas Education Service District has developed this model Healthy and Safe Schools Plan to comply with

More information

STUDY #3 IN A SERIES OF REPORTS ON RADON IN BC HOMES. Castlegar: COMMUNITY-WIDE RADON TESTING RESULTS AS PART OF ITS. PROGRAm

STUDY #3 IN A SERIES OF REPORTS ON RADON IN BC HOMES. Castlegar: COMMUNITY-WIDE RADON TESTING RESULTS AS PART OF ITS. PROGRAm STUDY #3 IN A SERIES OF REPORTS ON RADON IN BC HOMES Castlegar: COMMUNITY-WIDE RADON TESTING RESULTS AS PART OF ITS PROGRAm BC Lung Association The British Columbia Lung Association (BCLA) is one of the

More information

Public Review: MAMF - Proposed Revision 09/2016. Protocol for Conducting Measurements of Radon and Radon Decay Products in Multifamily Buildings

Public Review: MAMF - Proposed Revision 09/2016. Protocol for Conducting Measurements of Radon and Radon Decay Products in Multifamily Buildings Public Review: MAMF - Proposed Revision 09/2016 Protocol for Conducting Measurements of Radon and Radon Decay Products COMMENT DEADLINE: November 7 th, 2016 REQUESTED PROCESS AND FORM FOR FORMAL PUBLIC

More information

Certificate of Completion

Certificate of Completion Love the Lungs You re With 630-325-4443 800-244-4242 Certificate of Completion Every parent or guardian is notified that this facility has performed radon measurements to ensure the health and safety of

More information

Illinois School District & Daycares

Illinois School District & Daycares Illinois School District & Daycares Commercial Radon Test Final Measurement Report Radon Measurements of: NEWPORT ELEMENTARY SCHOOL LOCATED IN WADSWORTH, IL 15872 W. 21 ST STREET WADSWORTH, IL 60083 Approval:

More information

Property Inspected: 1228 Radcliffe Ave, Kingsport, TN 37664

Property Inspected: 1228 Radcliffe Ave, Kingsport, TN 37664 September 24, 2015 Test Number: 13-175 Property Inspected: 1228 Radcliffe Ave, Kingsport, TN 37664 Licensed Radalink Radon Inspector: Professional Home Inspections Kenneth Bartley Jr. 180 Kincheloe Road

More information

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Commercial Radon Survey Report Client: Community Consolidated School District 181 Site Address: Prospect School 130 N Prospect Clarendon Hills, IL 60514 Survey Date: April 23, 2012 to April 25, 2012 Initial

More information

C-NRPP Quality Assurance Guidance for Radon Test Devices

C-NRPP Quality Assurance Guidance for Radon Test Devices C-NRPP Quality Assurance Guidance for Radon Test Devices Table of Contents: 1. Purpose 2. Definitions 3. Quality Assurance Plan 4. Calibration 5. Spikes/Performance Tests 6. Duplicates 7. Blanks 8. Cross-Checks

More information

Radon Measurement Report

Radon Measurement Report Radon Measurement Report William Property Address: Akron OH 44319 Robert Lawrence Akron, Ohio 44319 330-256-6510 Officeprestigeinspections@gmail.com www.prestigeinspections.com Radon Mitigation Specialst

More information

How can you reduce radon in a home?

How can you reduce radon in a home? Lesson 10: How can you reduce radon in a home? Lesson overview This lesson provides a brief overview of radon mitigation. Lesson objectives By the end of this lesson, the learners will be able to: Describe

More information

Dealing With RADON in Real Estate Transactions

Dealing With RADON in Real Estate Transactions This document has been reproduced by the concerned professionals at: Colorado Department of Public Health and Environment March 2002 Dealing With RADON in Real Estate Transactions Colorado Department of

More information

Radon Detection Specialists, Inc. Love the Lungs You re With

Radon Detection Specialists, Inc. Love the Lungs You re With 630-325-4443 800-244-4242 kws@radonresults.com Commercial Radon Survey Report Client: Pleasantdale School District 107 8100 School Street La Grange, Illinois 60525 Survey Date: August 27, 2014 to August

More information

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Commercial Radon Survey Report Client: Community Consolidated School District 181 Site Address: Monroe School 210 N Madison Hinsdale, IL 60521 Survey Date: May 7, 2012 to May 9, 2012 Initial Test RDS-R-002

More information

3/22/2011. City Council City Hall Wilmington, North Carolina Dear Mayor and Councilmembers:

3/22/2011. City Council City Hall Wilmington, North Carolina Dear Mayor and Councilmembers: ITEM C2 OFFICE OF THE CITY MANAGER (910) 341-7810 FAX(910)341-5839 TDD (910)341-7873 3/22/2011 City Council City Hall Wilmington, North Carolina 28401 Dear Mayor and Councilmembers: Attached for your consideration

More information

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Commercial Radon Survey Report Client: Community Consolidated School District 181 Site Address: The Lane School 500 N Elm St Hinsdale, IL 60521 Survey Date: April 17, 2012 to April 19, 2012 Initial Test

More information

June 7, 2016 PINCHIN LTD 1. Managing Radon in Buildings A Canadian Perspective SEMINAR OUTLINE WHAT IS RADON?

June 7, 2016 PINCHIN LTD 1. Managing Radon in Buildings A Canadian Perspective SEMINAR OUTLINE WHAT IS RADON? Managing Radon in Buildings A Canadian Perspective SCOTT CRYER, P.GEO. MARCH 28, 2017 PINCHIN ALL RIGHT RESERVED SEMINAR OUTLINE What is Radon? Health Concerns Acceptable levels Radon in buildings Guidance/potential

More information

THE EFFECT OF BUILDING CODES AND HOUSE AGE ON RADON CONCENTRATIONS IN MINNESOTA

THE EFFECT OF BUILDING CODES AND HOUSE AGE ON RADON CONCENTRATIONS IN MINNESOTA THE EFFECT OF BUILDING CODES AND HOUSE AGE ON RADON CONCENTRATIONS IN MINNESOTA Daniel J. Steck Physics Department, St. John's University Collegeville, MN 5632 1 ABSTRACT Many public radon reduction programs

More information

2006 Radon Certification Training and Workshops

2006 Radon Certification Training and Workshops at Auburn University www.bece.auburn.edu/srrtc 2006 Radon Certification Training and Workshops Homebuilders Contractors Remodelers Home Inspectors Environmental Consultants HVAC Contractors Health Officials

More information

Dealing With RADON in Real Estate Transactions

Dealing With RADON in Real Estate Transactions This document has been reproduced by the concerned professionals at: Wyoming Department of Health Revised 2005 Dealing With RADON in Real Estate Transactions Wyoming Department of Health Wyoming Radon

More information

shown on the following page.

shown on the following page. ARCHITECTURE PLANNING URBAN DESIGN May 5, 2016 Ms. Tricia Schimpp Department of Community Development City of San Mateo 330 West 20th Avenue San Mateo, CA 94403-1388 RE: Hillsdale Terrace Dear Tricia:

More information

Radon YOU: What you need to know to protect you and your family

Radon YOU: What you need to know to protect you and your family Radon & YOU: What you need to know to protect you and your family What is radon? Radon is a colorless, odorless, tasteless, radioactive gas that is produced from the decay of naturally occurring uranium

More information

Home Buyer s and Seller s Guide to Radon

Home Buyer s and Seller s Guide to Radon www.epa.gov/radon Home Buyer s and Seller s Guide to Radon Indoor Air Quality (IAQ) EPA RECOMMENDS: Q If you are buying or selling a home, have it tested for radon. Q For a new home, ask if radon-resistant

More information

Property of Aztec Home Services LLC

Property of Aztec Home Services LLC Property of Aztec Home Services LLC 5.0 Test Conditions 5.1 Long-Term Tests (those lasting more than 90 days) do not require closed-building conditions. Longterm tests should be conducted as close to a

More information

Tax Parcels. Other Legal Features. Other Fee Parcels. Easements. Rights-Of-Way. Elevation Contour Lines. Interstate Routes.

Tax Parcels. Other Legal Features. Other Fee Parcels. Easements. Rights-Of-Way. Elevation Contour Lines. Interstate Routes. µ 6 Myles Lane Tax Parcels Other Legal Features Other Fee Parcels Easements Rights-Of-Way Elevation Contour Lines Interstate Routes Interstate Routes US & State Routes US & State Routes USGS, MassGIS Other

More information

YOU: What you need to know to protect you and your family

YOU: What you need to know to protect you and your family Radon & YOU: What you need to know to protect you and your family What is radon? Radon is a colorless, odorless, tasteless, radioactive gas that is produced from the decay of naturally occurring uranium

More information

Home Buyer s and Seller s Guide to Radon

Home Buyer s and Seller s Guide to Radon www.epa.gov/iaq Home Buyer s and Seller s Guide to Radon Indoor Air Quality (IAQ) EPA RECOMMENDS: Q If you are buying or selling a home, have it tested for radon. Q For a new home, ask if radon-resistant

More information

It is recommended that the Commission receive this report on subway garbage disposal and recycling and note the following:

It is recommended that the Commission receive this report on subway garbage disposal and recycling and note the following: MEETING DATE: FEBRUARY 27, 2001 SUBJECT: Subway Garbage Disposal RECOMMENDATION It is recommended that the Commission receive this report on subway garbage disposal and recycling and note the following:

More information

Indoor Environmental Quality

Indoor Environmental Quality The average person spends about 90% of their time indoor, a significant amount of time. Therefore, it is essential that houses provide a healthy and comfortable interior living environment. Conditions

More information

IN UNDER SERVED AREAS OF NEW YORK STATE

IN UNDER SERVED AREAS OF NEW YORK STATE OBTAINING ADDITIONAL INDOOR RADON MEASUREMENTS IN UNDER SERVED AREAS OF NEW YORK STATE Michael E. Kitto and Charles 0. Kunz Wadswonh Center. New York State Department of Health and School of Public Health,

More information

Radon Partnerships in Minnesota. Indoor Air Unit Radon Program Local Public Health Association Meeting January 18, 2018

Radon Partnerships in Minnesota. Indoor Air Unit Radon Program Local Public Health Association Meeting January 18, 2018 Radon Partnerships in Minnesota Indoor Air Unit Radon Program Local Public Health Association Meeting January 18, 2018 1 Agenda Basics Cancer Plan Partnership 1/18/2018 MDH Indoor Air mn.gov/radon 2 Technical

More information

Home Buyer s and Seller s Guide to Radon

Home Buyer s and Seller s Guide to Radon United States 402-K-05-005 Environmental Protection May 2005 Agency ---------------------------------------------------------------------------------------------------------------Air and Radiation (6609-J)

More information

Table of Contents EPA (Radon).1 CPSC (Safety) 43 Business.48

Table of Contents EPA (Radon).1 CPSC (Safety) 43 Business.48 Table of Contents EPA (Radon).1 CPSC (Safety) 43 Business.48 Home Buyer s and Seller s uide to Radon EPA RECOMMENDS: Q Q Q Q Q If you are buying or selling a home, have it tested for radon. For a new home,

More information

Inspection Dates: March 21 March 22, 2016 Report Date: March 31, 2016

Inspection Dates: March 21 March 22, 2016 Report Date: March 31, 2016 Lead-Based Paint Inspection Broadway Terrace Apartments 1504-1508 Broadway Street Ann Arbor, Michigan Ann Arbor Housing Commission Inspection Dates: March 21 March 22, 2016 Report Date: March 31, 2016

More information

AVERAGE RADON CONCENTRATION:

AVERAGE RADON CONCENTRATION: November 23, 2011 Test Number: 1092-192 roperty Inspected: 190 Orchard Heights Drive, South Bend, IN 614 Licensed Radalink Radon Inspector: Certified Home Inspections Dawn Hatfield 19237 Edinburgh Drive

More information

February 5, 2016 Test Number:

February 5, 2016 Test Number: February 5, 2016 Test Number: 8401-12 Property Inspected: 702 Henderson Ave., Columbus, OH 43214 Licensed Radalink Radon Inspector: ACME Home Inspections John Harwell 32 N. High St. Columbus, OH 43202

More information

Connecticut Radon Measurement Training Program

Connecticut Radon Measurement Training Program Lesson 10 How can you reduce radon in a home? Brief overview of radon mitigation Mitigation: reducing radon in air or water Requires trained, registered radon mitigation specialist Typical radon mitigation

More information

Fire Inspector and Investigators Career Path Exploration. Angela Gervais and Edward J. Lazaros. Ball State University

Fire Inspector and Investigators Career Path Exploration. Angela Gervais and Edward J. Lazaros. Ball State University Fire Inspector and Investigators Career Path Exploration Angela Gervais and Edward J. Lazaros Ball State University agervais@bsu.edu; ejlazaros@bsu.edu Introduction The motive of this article is to provide

More information

The Effects of the Contact Herbicide Diquat on Mixed Stands of Flowering Rush and Hardstem Bulrush in Lake Sallie, Minnesota 2015

The Effects of the Contact Herbicide Diquat on Mixed Stands of Flowering Rush and Hardstem Bulrush in Lake Sallie, Minnesota 2015 The Effects of the Contact Herbicide Diquat on Mixed Stands of Flowering Rush and Hardstem Bulrush in Lake Sallie, Minnesota 2015 Gray Turnage 1, Brent Alcott 2, and Tera Guetter 2 1 Geosystems Research

More information

Buying a New Home? How to Protect Your Famil... Page 1 of 6

Buying a New Home? How to Protect Your Famil... Page 1 of 6 Buying a New Home? How to Protect Your Famil... Page 1 of 6 Office of Air and Radiation EPA/402-F-98-008 April 1998 Radon causes an estimated 14,000 lung cancer deaths each year. It is the earth's only

More information

Rough rice should be dried to a certain moisture

Rough rice should be dried to a certain moisture fpe 1599 ms 7/9/01 3:33 PM Page 1709 ASTUDY OF HEAD RICE YIELD REDUCTION OF LONG- AND MEDIUM-GRAIN RICE VARIETIES IN RELATION TO VARIOUS HARVEST AND DRYING CONDITIONS J. Fan, T. J. Siebenmorgen, W. Yang

More information

DOWNLOAD : RADON MITIGATION COLORADO

DOWNLOAD : RADON MITIGATION COLORADO DOWNLOAD : RADON MITIGATION COLORADO TESTING AND MITIGATING YOUR HOME FOR RADON - COLORADO the most effective solution is usually a sub-slab (or if you have a crawl space, sub-membrane) depressurization

More information

APPENDIX J SHPO COORDINATION

APPENDIX J SHPO COORDINATION Final Environmental Impact Statement/Final Environment Impact Report Appendix J SHPO Coordination APPENDIX J SHPO COORDINATION August 2011 CRENSHAW/LAX TRANSIT CORRIDOR PROJECT Final Environmental Impact

More information

Policy Manual. April 21,2015. National Radon Proficiency Program 2015

Policy Manual. April 21,2015. National Radon Proficiency Program 2015 Policy Manual April 21,2015 National Radon Proficiency Program 2015 AARST - National Radon Proficiency Program (NRPP) ~ Page 1 TABLE OF CONTENTS I. General Application 4 II. Residential Measurement Provider

More information

MOBILE CITY PLANNING COMMISSION LETTER OF DECISION. October 22, 2010

MOBILE CITY PLANNING COMMISSION LETTER OF DECISION. October 22, 2010 MOBILE CITY PLANNING COMMISSION LETTER OF DECISION Archbishop of Mobile 400 Government St. Mobile, AL 36602 Re: Case #SUB2010-00075 (Subdivision) 3650 Springhill Avenue (Northwest corner of Springhill

More information