DETECTION. confined space. Professional. New OSHA Rule: Product Spotlight: A Reminder of the Importance of Atmospheric Testing and Monitoring
|
|
- Shanon Reed
- 5 years ago
- Views:
Transcription
1 Issue 2 A publication of SENSIT Technologies DETECTION confined space New OSHA Rule: A Reminder of the Importance of Atmospheric Testing and Monitoring Product Spotlight: SENSIT P400 Multi-Gas Monitor SCAL-400 Charging & Calibration Station Professional
2 Trak-It IIIa Heavy-Duty CGI Multi-Gas Monitor Trak-It IIIa is a Combustible Gas Indicator designed for extreme working conditions. This multi-function instrument is ideal for gas leak pin-pointing and confined space applications. Trak-It IIIa displays up to 4 gases including O2, CO, H2S and can be configured for combustible gas readings in PPM, LEL and/or percent volume. Learn more at 7WA6 ATEX APPROVED
3 President s Message It is hard to believe that 2015 is rapidly approaching the end. I would like to say thank you to all our valued customers for their business and the trust you have in Sensit Technologies. I am humbled by your commitments as well as by our dedicated employees that work tirelessly to provide you the highest quality products and service, second to none. Looking to 2016 and beyond, Sensit Technologies is poised for continued growth. We will bring more game-changing products that allow our customers to work more safely and efficiently. Innovation is the cornerstone to creating the value proposition we bring to the markets we serve. J. Scott Kleppe President and Chief Executive Officer This edition of Detection Professional highlights the important changes to the newest OSHA rulings for confined space entry. Every industry we serve is impacted to some degree - some a little more due to the increased reach of what is considered a confined space. Regardless of the inconvenience some of these rulings create, the ultimate goal for OSHA is that everyone goes safely home after their day s work. This is something we take very seriously not only in our role as an equipment consultant and provider, but also as an employer. Thank you for taking the time to read Detection Professional. It is our way to keep customers up to date with relevant information that impacts their world. Please feel free to forward Detection Profession to others if you would like. We also welcome any comments or questions. All the best, J. Scott Kleppe President and Chief Executive Officer 3
4 Feature Article New OSHA Rule for Confined Spaces In May, 2015, OSHA published its long-awaited final rule on safety requirements for confined spaces in the construction industry, which now includes attics and crawlspaces - areas where HVAC workers are sometimes required to enter. Full enforcement commenced October 2, The new standard comes 22 years after the initial OSHA rule that covered confined space entry for general industry. However, that original standard did not cover employees entering confined spaces while engaged in construction work. This new rule provides construction workers the same level of protection working in confined spaces as workers in manufacturing and other industries. According to OSHA, nearly 1,000 people are injured in confined spaces at construction sites each year. OSHA believes the new standard will prevent the vast majority of those injuries. Confined spaces (including attics, manholes, and crawl spaces) are not designed for continuous occupancy and are difficult to exit in the event of an emergency. People working in confined spaces face life-threatening hazards including toxic substances, electrocutions, explosions, and asphyxiation. While some industrial and commercial HVACR contractors have likely already adapted their work rules to OSHA requirements, residential HVAC contractors will also need to make sure they comply. Why was a new rule developed? The original OSHA rule did not cover employees entering confined spaces while engaged in construction work. It was found that, in general, confined spaces in construction environments were not usually identified or classified prior to the beginning of a project. Additionally, OSHA specifically included crawl spaces and attics after two separate incidents that led to the deaths of three workers. In one case, two workers died while applying primer to floor joists in a crawl space. They were burned when a work lamp ignited vapors from the primer. In a separate incident, a worker was killed in a flash fire when he was spraying foam insulation in an attic with poor ventilation. 4 DETECTION PROFESSIONAL Issue 2
5 A confined space is defined as one that is large enough and configured such that: An employee can enter and perform work; It has limited or restricted means for entry or exit; It is not designed for continuous employee occupancy Confined spaces may require a permit, which means the space contains or has the potential to contain a hazardous atmosphere. A permit-required space may also contain other recognized safety and health hazards. The space must be tested before entry and continuously monitored when possible with a directreading gas monitor. Once a confined space is identified, it is necessary to test the atmosphere for potential hazards and the components of the traditional combustion triangle (oxygen, fuel, and an ignition source). Oxygen levels must be checked using a properly calibrated gas monitor to insure that levels are sufficient to allow work in the confined space and determine if the area is potentially hazardous or explosive. If the workplace is a Permit-Required Confined Space, employers must provide results of any atmospheric testing and inform employees with posted signs. Employers also must ensure that the space is monitored for hazards, especially atmospheric, because multiple contractors may be operating on site. Per the standard, employers must provide pre-entry planning before employees enter the confined space. This plan includes: having a competent person evaluate the work site for the presence of confined spaces identifying the means of entry and exit ensuring that the air is tested before entry for oxygen levels and combustible and toxic gases proper ventilation or evacuation of potential hazards in a permit-required space determining rescue procedures and deployment of monitoring equipment Crawl spaces and attics may be considered confined spaces (permit or non-permit-required) under the new standard. For example, workers installing plumbing in a crawl space could be exposed to low oxygen levels or toxic gases and thus need to take the necessary steps to comply. Similarly, workers installing insulation in an attic may be required to have documented safety plans and operate under the OSHA requirements. Employees in these circumstances may need to be outfitted with personal monitors to continuously detect and alert them of potential threats. To help employers, workers, and others understand the new requirements, visit confinedspaces/ Visit our website at com for more information on SENSIT Technologies Confined Space monitoring products including: SENSIT P400 multi-gas monitor can display up to 5 gases simultaneously including O2, combustibles, CO, H2S, HCN, NO2, and SO2 SENSIT P100 single gas monitor warns the user of hazardous gases in their working environment. Available sensors include: O2, CO, H2S, HCN, NO2, and SO2. SENSIT GOLD G2 multi-function gas detector displays up to 4 gases simultaneously including O2, combustibles, CO, H2S, or HCN SENSIT GOLD 100 multi-function gas detector displays up to 4 gases simultaneously including O2, combustibles, CO, H2S, or HCN. Trak-It llla combustible gas indicator displays up to 4 gases simultaneously including O2, combustibles, CO, and H2S. 5
6 Product Spotlight SENSIT P400 Personal Monitor Multi Gas Monitor Offers Durability and Industry-Leading Features The SENSIT P400 offers sensor options for monitoring up to five gases simultaneously. Sensor Options include combustibles, hydrogen sulfide, oxygen, carbon monoxide, sulfur dioxide and other toxic gases such as hydrogen cyanide; common in fire smoke. Scott Kleppe, President and CEO, Sensit Technologies, notes SENSIT P400 Gas Monitor meets UL and ATEX intrinsic safety standards. The device is easy to use, rugged and highly responsive. During hazardous conditions, users are alerted via three alarm functions: vibration, red flashing LEDs and audible alarm. The SENSIT P400 offers a large backlit graphic display and heavyduty clip that attaches easily onto a belt or vest. The instrument uses 4 AA Alkaline batteries and is also available with rechargeable NiHM battery pack and charger station. The SENSIT P400 can be configured with an optional Immediate Detection System (IDS) which provides early warning to changes in the users working environment. SENSIT P400 is available with standard 2-year warranty with a 4-year warranty option available. COMPLIANCE/ STATUS INDICATOR ALARM LEDs SENSOR AREA SENSOR FILTER FUNCTION BUTTONS SOUNDER GRAPHIC DISPLAY w/back LIGHT BELT CLIP (ON BACK) Patented SENSOR SPECIFICATIONS RESPONSE TYPE RESOLUTION RANGE ACCURACY T90 TIMES LEL 0.1% ±10% < 10 Sec O2 0.1% 25% ±2% or 10%** < 10 Sec CO 1ppm 0-999* ±5ppm or 10%** < 10 Sec H2S 1ppm ±2ppm or 10%** < 20 Sec HCN 0.1ppm 0-30 ±1ppm or 10%** < 20 Sec *CO Extended Range Available 0ppm ppm. ** Whichever is greater 6 DETECTION PROFESSIONAL Issue 2
7 Product Spotlight Calibration & Charging Station Improve Compliance, Record Keeping, Efficiency, and Accuracy. SCAL-400 Station automatically charges, bump tests and calibrates up to five SENSIT P400 Gas Monitors simultaneously. SCAL-400 Station features a touch screen display. Use your finger or the included stylus, to access instrument and station information. Simply place an instrument onto any of the five slots. Each slot contains charger and communication connections. Testing functions require no user interaction. During connection, the station automatically detects when an instrument requires a bump or calibration, and then performs the required test. SCAL-400 Calibration and Charging Stations come with SCAL-D Data Management Software. SCAL-N (Network) is sold separately with a multiyear license. Use SCAL-N to download data from remotely located Calibration Station(s). Data is stored in SQL Server. 7
8 Case Study SENSIT P100 provides lifesaving protection against invisible threats The Client An Emergency Medical Service company in Canada serving the region s 250,000 citizens. The Situation The role of the region s EMS workers is to provide treatment to those in need of medical care and to provide timely removal and transport of the patient to the next point of care. EMS workers are trained and educated to handle a wide variety of situations and threats that could be encountered in the field. They are called to homes and businesses throughout the region to provide emergency medical care and other services and must be prepared for both obvious and invisible threats to themselves and the public. SENSIT Solution This EMS company has approximately fifty SENSIT P100 CO (Carbon Monoxide) monitors deployed among its crews. The P100 CO is attached to their emergency response bag (oxygen kit) which is carried into every call made by the paramedic. This protects the paramedic and the public from undetected CO that can collect and build to lethal concentrations. In a two week span, the EMS crews were called to two separate factories for employees experiencing nausea and generally unwell conditions. In both cases, upon entering the building, the paramedic s P100 monitors alarmed. He knew right away that the CO levels were above the 50 ppm alarm threshold set on the monitors. The EMS crew evacuated the buildings and then worked quickly with management to shut down the plant so an investigation could commence by the company to find the source of the unsafe CO levels. Another instance during last year s brutally cold winter; an ice storm caused an electrical blackout in the region. EMS was called to a residence with a homeowner feeling sick. It was learned that the homeowner was using a gas-powered generator in an unsafe way, and actually removed the generator prior to calling 911. The EMS worker said he was no more than 10 steps into the residence when the SENSIT P100 began to alarm. He quickly located the resident, removed her from the building, and updated other responding crews to the danger. The patient had very high carboxyhemoglobin (CO levels in the blood) and was sent to a hyperbaric chamber to accelerate removal of carbon monoxide from her system. The P100 provided the protection needed, not only for the EMS worker, but also for the patient to ensure a good outcome. Results & Impact One of the managers of the EMS unit told Detection Professional that he estimated that over the course of the 4 years since they began using the P100, the monitors have identified dangerous levels of CO in a building or home 20 to 30 times. He went on to say, In my opinion, all paramedics and other first responders should have a CO detecting monitor for personal protection when entering an unknown environment. With its low price and low maintenance cost, it is affordable for even the smallest rescue service companies. 8 DETECTION PROFESSIONAL Issue 2
9 Awareness TOXIC GAS HAZARDS Oxygen Content of Air: Asphyxia Symptoms for Low Oxygen Levels* 19.5% May affect physical and intellectual performance without a person s knowledge. 18% Decreased ability to work strenuously. May impair coordination and may induce symptoms in persons with coronary, pulmonary or circulatory problems. 15% Respiration deeper, increased pulse rate and impaired coordination, perception and judgment. 12% Further increase in rate and depth of respiration, further increase in pulse rate, performance failure, giddiness, poor judgment, blue lips. 10% Mental failure, nausea, vomiting, fainting, ashen face, blue lips. 8% Loss of consciousness within a few minutes, resuscitation possible if carried out immediately. 6-0% Loss of consciousness almost immediate, death ensues, brain damage even if rescued. * Health effects can vary significantly based on age, sex, weight and overall state of health. 9
10 Frequently Asked Questions Customer Service Q: When will my order ship? A: SENSIT Technologies typically ships orders within 2 weeks after receipt of order. Need it sooner? Ask about expediting your order. Q: Can my order ship today? A: SENSIT Technologies Customer Service Representative will be happy to check about expediting your order. Additional fees apply for Same Day shipment. Q: What if I m not sure which gas detector is best for me? A: Our Customer Service Representative will discuss your application and provide options that best fit your needs. The Customer Service Representative can also help identify the correct part number for your product and provide a formal quotation upon request. Q: Where are the products manufactured? A: Sensit Technologies manufacturing facility is located in Valparaiso, Indiana. Q: How are instruments and gases shipped? A: All instruments and accessories ship from SENSIT Technologies in Valparaiso, Indiana. Shipments are made via UPS Ground unless otherwise noted by the customer. Additional fees apply for Next and 2nd day Air. Note that certain calibration gas cannot ship via air freight due to restrictions regarding flammability. A: What is the procedure for returning an instrument for repair or calibration? Q: Contact SENSIT Customer Service at or go to to download a Return Authorization form. Fill out the form completely and include it in the shipping box with the instrument. Be sure to protect the instrument for shipping. Please include your contact information. Note whether you would like an estimate prior to the repair being completed. Payment for repair and calibration services can be made via invoice or credit card. 10 DETECTION PROFESSIONAL Issue 2
11 The most versatile gas leak detector available today! SENSIT GOLD G2 can be used for gas leak surveys and investigations, leak pinpointing, line purging and confined space applications. Displays Up To 4 Gases LEL (%Volume and PPM Optional) Oxygen Carbon Monoxide Hydrogen Sulfide Selectable Gas Type Methane (Natural Gas) Propane Find Gas Leaks Fast! Learn more at:
12
SENSIT PROPANE GAS. 4Gas Leak Detectors 4Hazardous Gas Monitors 4Calibration Stations 4Data Management 4Pipe Locators ENERGY INDUSTRIES
SENSIT 2 0 1 8 P R O D U C T G U I D E PROPANE GAS ENERGY INDUSTRIES 4Gas Leak Detectors 4Hazardous Gas Monitors 4Calibration Stations 4Data Management 4Pipe Locators The Company: SENSIT Technologies is
More informationPRODUCT GUIDE. Gas Leak Detectors Gas Monitors Pipe & Joint Locators Calibration Stations Data Management MUNICIPAL SERVICES
Innovative Detection Solutions www.gasleaksensors.com MUNICIPAL SERVICES PRODUCT GUIDE Gas Leak Detectors Gas Monitors Pipe & Joint Locators Calibration Stations Data Management The Company: SENSIT Technologies
More informationSENSIT FIRE SERVICE. 4Hazardous Gas Monitors 4Gas Leak Detectors 4Calibration Stations 4Data Management EMERGENCY RESPONSE
SENSIT 2 0 1 8 P R O D U C T G U I D E FIRE SERVICE EMERGENCY RESPONSE 4Hazardous Gas Monitors 4Gas Leak Detectors 4Calibration Stations 4Data Management The Company: SENSIT Technologies is an ISO 9001:2008
More informationConfined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012
Confined Space Monitoring Leak Investigation 1 Functions 4 Bar Hole Sampling Line Purge Testing Actual Size GX-2012 3 Operating Modes Internal sample draw pump with 50 range Low flow alarm 3 bright visual
More informationT.ex Single Gas Detector VISA
T.ex Single Gas Detector The T.ex is newest instrument in the Promat portfolio. The instrument is currently available in Oxygen, Hydrogen Sulphide and Carbon Monoxide versions. A Bump Test Station is available
More informationSENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector
SENSIT HXG-2 Instruction Manual For use with combustible gases Gas Leak Detector CLASSIFIED 7WA6 Approved UL913, For Class 1, Division 1, Groups C & D hazardous locations when used with alkaline batteries.
More informationCARBON MONOXIDE (CO)
DCN: 3.02.16 FIRE TACTICS AND PROCEDURES HAZARDOUS MATERIALS 4 March 15, 1997 (CO) 1. INTRODUCTION 1.1 Due to increased public awareness and the availability of carbon monoxide (CO) detectors for the home,
More informationSENSIT MUNICIPAL. 4Gas Leak Detectors 4Hazardous Gas Monitors 4Calibration Stations 4Data Management 4Pipe Locators GOVERNMENT SERVICES
SENSIT 2 0 1 8 P R O D U C T G U I D E MUNICIPAL GOVERNMENT SERVICES 4Gas Leak Detectors 4Hazardous Gas Monitors 4Calibration Stations 4Data Management 4Pipe Locators The Company: SENSIT Technologies is
More information2.1 CO is a colorless, odorless, tasteless, non-irritating, toxic gas.
FIRE TACTICS AND PROCEDURES March 15, 1997 (CO) 1. INTRODUCTION 1.1 Due to increased public awareness and the availability of carbon monoxide (CO) detectors for the home, the Fire Department is being called
More informationResponse to Carbon Monoxide Incidents. W.J. Streett Jr Training Section Chief
Response to Carbon Monoxide Incidents W.J. Streett Jr Training Section Chief The Secret to Success Joe Loving and his faithful hunting companion bag another big buck Overview Introduction Carbon Monoxide
More information5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots
5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots GX-6000 5 Operating modes Normal Leak Check Inert Bar hole Snap Log Monitor up to
More information5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots
5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots CONFINED SPACE ENTRY Monitor LEL, O2, CO, and H2S Internal sample pump Pull samples
More informationALTAIR 5X Multigas Detector
ALTAIR 5X Multigas Detector With MSA XCell Sensor Technology IT S WHAT S INSIDE THAT COUNTS Now with advanced PID for VOC detection Because every life has a purpose... Save Time, Save Money, Save Lives
More informationDETECTION. Professional. Residential Energy Audits. New product from SENSIT Technologies meets the need. A publication of SENSIT Technologies
Issue 4 A publication of SENSIT Technologies DETECTION Professional Residential Energy Audits New product from SENSIT Technologies meets the need ultra-trac apl with 3D Pipe Mapping LOCATE PIPELINES with
More informationALTAIR 5X Multigas Detector
ALTAIR 5X Multigas Detector With MSA XCell Sensor Technology IT S WHAT S INSIDE THAT COUNTS Now with advanced PID for VOC Detection Because every life has a purpose IT S WHAT S INSIDE THAT COUNTS WORKERS
More informationSENSIT NATURAL GAS. 4Gas Leak Detectors 4Hazardous Gas Monitors 4Calibration Stations 4Data Management 4Pipe Locators ENERGY INDUSTRIES
SENSIT 2 0 1 8 P R O D U C T G U I D E NATURAL GAS ENERGY INDUSTRIES 4Gas Leak Detectors 4Hazardous Gas Monitors 4Calibration Stations 4Data Management 4Pipe Locators The Company: SENSIT Technologies is
More informationSENSIT GOLD G2 II 2 G INSTRUCTION MANUAL. Gas Detection Instrument. Read and understand instructions before use.
INSTRUCTION MANUAL SENSIT GOLD G2 Gas Detection Instrument For use with combustible gases and optionally available oxygen and toxic gases. Read and understand instructions before use. II 2 G 0891 Ex ib
More informationSENSIT GOLD G2 INSTRUCTION MANUAL For use with combustible gases and optionally available oxygen and toxic gases.
PARTS AND ACCESSORIES Standard Accessories (included) Carrying Case, Alkaline Batteries, Wrist Strap, Extra Sensor Cap with O-Rings, T10 Torx Wrench and Instruction Manual Accessories and Replacement Parts
More informationEAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility
EAGLE 2 Inlet fitting Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility Internal / external hydrophobic filters Self healing polyurethane protective
More informationNATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling
NATURAL GAS DETECTOR Confined Space Monitor Leak Investigation Line Purge Testing Bar Hole Sampling CONFINED SPACE ENTRY Monitor LEL, O2, CO, and H2S Smallest 5 sensor sample draw instrument Internal sample
More informationup to 1.2 m or 3.9 ft. deep). So if you drop the Honeywell BW Ultra in a vat or take it into a dust-prone environment,
BW ULTRA User-Friendly Portable Five-Gas Detection in Confined Spaces Designed specifically for sampling and monitoring confined spaces, before and after entry, Honeywell BW Ultra offers enhanced sensor
More informationNJSP HMRU. Module 5 B HM Operations 1
THE MATERIAL PRESENTED IN THIS MODULE IS INTENDED AS AN OVERVIEW. SPECIFIC INFORMATION ON CALIBRATION, OPERATION, AND INTERPRETATION OF RESULTS SHOULD BE OBTAINED FROM EQUIPMENT MANUFACTURERS. IDENTIFYING
More informationArvada Fire Uses Advanced Gas Monitors To Keep Citizens and Responders Safe
Arvada Fire Uses Advanced Gas Monitors To Keep Citizens and Responders Safe In Arvada, Colorado, a 911 call was received from someone who reported that a family member was not feeling well. The caller
More informationSafe Operation Manual. Honeywell IQ Force Gas Detector
Safe Operation Manual Honeywell IQ Force Gas Detector Honeywell Analytics 800-663-4164 403-248-9226 Fax 403-575-3708 03JUN2012 P/N 50105843-047 Version 01 http://www.honeywell.com HONEYWELL IQ Force PERSONAL
More informationVENTIS PRO SERIES. Product Guide
VENTIS PRO SERIES Product Guide BE READY FOR THE MOMENT In your line of work, a day on the job can turn from habit to hazard in a single moment. Be ready for anything with the Ventis Pro Series Multi-Gas
More informationGasAlertMicroClip X3 Specifications
GasAlertMicroClip X3 Specifications The instrument must satisfy the following: Physical Specifications Size (h x w x d) Physical size shall be no larger than 4.4 x 2.4 x 1.2 in. / 11.3 x 6.0 x 3.2 cm Weight
More informationMODEL: SP12C7. (Portable 4 gas detector) Operating Manual
MODEL: SP12C7 (Portable 4 gas detector) Operating Manual Guarantee and Repair Senko Co., Ltd. guarantees the products of SP series for 24 months from the shipping date and repairs or replaces the defected
More informationMacurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions
Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions Important: Keep these User Instructions for reference 2 TABLE OF CONTENTS GENERAL SAFETY
More informationFrequently Asked Questions About Carbon Monoxide Detectors
Frequently Asked Questions About Carbon Monoxide Detectors What is carbon monoxide (CO) and why do I need a carbon monoxide detector? Carbon monoxide is a colorless, odorless, tasteless and toxic gas produced
More informationWhat is carbon monoxide (CO) and why do I need a carbon monoxide detector?
What is carbon monoxide (CO) and why do I need a carbon monoxide detector? Carbon monoxide is a colorless, odorless, tasteless and toxic gas produced as a by-product of combustion. Any fuel burning appliance,
More informationCarbon Monoxide Detection in Buildings Frequently Asked Questions
What is carbon monoxide? Carbon Monoxide Detection in Buildings Frequently Asked Questions Carbon monoxide (CO) is a colorless, odorless, tasteless, poisonous gas that is produced by the incomplete burning
More informationMSA Portable Gas Detection
Because every life has a purpose MSA Portable Gas Detection Marine Chemist Association Seminar 2015 Paul Jung Product Line Manager Portable Instruments Our Mission & Vision Mission to see to it that men
More informationModel:AS8900 MULTI-GAS MONITOR O 2 %VOL H 2S PPM LEL%VOL CO PPM. Version number:as
Model:AS8900 MULTI-GAS MONITOR O 2 %VOL H 2S PPM LEL%VOL CO PPM Version number:as8900-0-1 CONTENTS 1.NOTICE BEFORE USE Cautions and warnings -------------------------- (01) Unit packing----------------------------------------
More informationOperate the Mutli-Gas Monitor PID
TASK: Operate the Multi-Gas Monitor Learning Objective CONDITION: In a classroom environment, given a fully charged Multi-gas Monitor with the manufacturer operator s manual, all monitor components/accessories,
More informationBw Gas Alert Clip 2 H2s Extreme User Manual
Bw Gas Alert Clip 2 H2s Extreme User Manual BW Clip is a maintenance-free single-gas detector for hazardous BW Clip maintenance-free single-gas detector is the most reliable, user-friendly, hibernation
More informationMonitores Personales. Personal Monitor
Monitores Personales Personal Monitor Micro IV Full Featured Personal Monitor Micro IV Single-gas Detector Highly configurable smart sensor design Wide range of sensors including O 2, H 2 S, CO, NH 3,
More informationModel GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com
Model GD-3300 Combustible Gas Leak Detector Instruction Manual reedinstruments com Introduction The Combustible Gas Leak Detector has a 16 gooseneck probe to find leaks in hard-to-reach areas. It s adjustable
More informationCarbon Monoxide Poisoning
National Grid Group Training Exercise #4 This training reflects industry best practices but does not replace your organization s SOPs/SOGs. This material can be utilized to provide a perspective as you
More informationQuality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.
Water Quality Labo- Soil/ Soil/ Sedi- Sam- & Air / Dust Toxic gases are present in a wide variety of industrial and civil installations and their detection and monitoring is crucial for the safe working
More informationMULTI-GAS MONITOR. Eastern Energy Co., Ltd. 40/4 Vitoondumri Rd., Banbueng Banbueng, Chonburi, Thailand
Model:AS8900 MULTI-GAS MONITOR O 2 %VOL H 2S PPM LEL%VOL CO PPM Eastern Energy Co., Ltd. 40/4 Vitoondumri Rd., Banbueng Banbueng, Chonburi, Thailand Tel: 66-3844-6117 sale@ete.co.th Version number:as8900-0-1
More informationSENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)
WARRANTY AND REPAIR POLICY Your SENSIT HXG-2d instrument is warranted to be free from defects in materials and workmanship for a period of two years after purchase (excluding sensor, calibration and batteries).
More informationFor the Safety of Your
For the Safety of Your Team in Confined Spaces CSM 5000 Portable Multi-Gas Monitor H 2 S OX CO EX Do it Right Do it Safe Power/Select Button Used for turning the CSM 5000 ON and OFF, accessing download
More informationContent Rev
SASKPOWER RED TAG PROGRAM USER MANUAL Content Rev. 2008-11-17 INDEX Preface 2 Scope 2 Definitions 2 Notification 3 Reporting Procedures 3 Returning the Corrected Red Tag Defect 4 Sample Red Tag (two sided
More informationFire Prevention Plan Program
Fire Prevention Plan Program Effective Date: Revision #: Reference Standard Purpose Occupational Safety and Health Administration (OSHA) standard, 29 CFR 1910.39 Subpart E, Fire Prevention Plan This procedure
More informationTravis County Emergency Services District #1 Standard Operating Guidelines
PURPOSE CARBON MONOXIDE To establish a procedure for response to carbon monoxide (CO) incidents, to insure the safety of both the firefighters and the public, and to allow for safe incident mitigation.
More informationII 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA
SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING II 2 G Ex ib IIB T3 IP20 PENDING (USA) Class 1, Division 1, Groups C and D, T3 Suitable for
More informationALTAIR 5X Multigas Detector Product Specification
ALTAIR 5X Multigas Detector Product Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Weight Handling Case material Environmental protection Display
More informationFire Prevention Plan
Fire Prevention Plan TABLE OF CONTENTS Section Title Page 1.0 Objective. 3 2.0 Background 3 3.0 Assignment of Responsibility.. 4 4.0 Plan Implementation..... 5 5.0 Types of Hazards...... 6 6.0 Training........
More informationFire Prevention Plan
Fire Prevention Plan TABLE OF CONTENTS Section Title Page 1.0 Objective. 3 2.0 Background 3 3.0 Assignment of Responsibility.. 4 4.0 Plan Implementation..... 5 5.0 Types of Hazards...... 6 6.0 Training........
More informationSENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20
SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex II3G Ex ic llb T3 IP20 PENDING (USA) Class 1, Zone 2, AEx nl llb T3 PENDING (Canada) Class
More informationCarbon Monoxide Alarm
Carbon Monoxide Alarm Benefits of the Carrier Carbon Monoxide Alarm INTRODUCTION A very serious and often ignored issue in the home is the possible presence of carbon monoxide (CO) gas. Carbon monoxide
More informationSENSIT HXG-2d Combustible Gas Detector
INSTRUCTION MANUAL SENSIT HXG-2d Combustible Gas Detector Read and understand instructions before use. 710183 UL 913 Intrinsically Safe for Use in Class I, Groups C and D, T3 Hazardous Locations For use
More informationChoosing the best confined space gas detector
AP1003: Choosing the best confined space gas detector The best confined space gas detector doesn t come from any one manufacturer; it s the instrument that best fulfills the requirements for your confined
More informationManhattan Fire Protection District
Section: RESCUE OPERATIONS Page 1 of 5 PURPOSE: This procedure is established to ensure proper detection and mitigation of carbon monoxide alarms and emergencies, and to provide a standard of response
More informationModel R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com
Model R9400 CO Meter with Temperature Instruction Manual com Table of Contents Safety... 3 Features... 3 Specifications... 4 Instrument Description... 5 Operating Instructions...6-7 Selecting Temperature
More informationMODEL: SP12C7. (Portable 4 gas detector) Operating Manual
MODEL: SP12C7 (Portable 4 gas detector) Operating Manual Guarantee and Repair Senko Co., Ltd. guarantees the products of SP series for 24 months from the shipping date and repairs or replaces the defected
More informationDräger X-am 7000 Multi-Gas Detection
Dräger X-am 7000 Multi-Gas Detection Dräger X-am 7000 is the solution for the simultaneous and continuous measurement of up to five gases. It is the ideal companion in a variety of applications where the
More informationWATCHMAN MULTIGAS MONITOR
WATCHMAN MULTIGAS MONITOR 08-02-39 FEATURES Continuously monitors combustible gases, oxygen, carbon monoxide and other toxic gases simultaneously; displays gas concentrations over large, easy-to-read digital
More informationGas Detection. - Disposable - Serviceable. Single Gas Detectors
Gas Detection Single Gas Detectors Introduction Portable single gas detectors are used for personal protection and have the ability to detect a single gas hazard. Typically they are small, lightweight
More informationTEXAS A&M UNIVERSITY EMERGENCY MANAGEMENT. Home Safety. Smoke Alarms
Smoke Alarms If you have a fire, smoke alarms can cut nearly in half your risk of dying in a fire. Smoke alarms sense abnormal amounts of smoke or invisible combustion gases in the air. They can detect
More informationSingle Gas Monitor 777
Single Gas Monitor 777 Carbon Monoxide The Value Leader TM www.tpi-thevalueleader.com Contents Agency Listings... 1 Safety Information... 2 General Description & Physical Specifications... 3 Product Features...4
More informationCarbon Monoxide Alarm Response Guide. High Country Training Center Training On Demand
Carbon Monoxide Alarm Response Guide High Country Training Center Training On Demand Objectives Look at Home CO detectors Everything you do and don t want to know about CO detectors Fire Department CO
More informationModel Carbon Monoxide (CO) Alarm Response Policy
Published on MTAS (http://www.mtas.tennessee.edu) January 26, 2019 Model Carbon Monoxide (CO) Alarm Response Policy Summary: This model policy was created to provide procedures for personnel to follow
More informationFire Safety Awareness Workbook
Fire Safety Awareness Workbook For All Staff Please ensure you read the workbook thoroughly and complete the assessment at the end Version 2. Introduction Fire safety training is a mandatory element of
More informationBP MAINTENANCE WORK INSTRUCTIONS FREQUENTLY ASKED QUESTIONS
BP MAINTENANCE WORK INSTRUCTIONS FREQUENTLY ASKED QUESTIONS The following FAQ was last updated 30/3/2016. This material is guidance only. If any of the content contradicts with requirements within the
More informationSafety Siren. Owner's Manual. Family Safety Products Inc. Carbon Monoxide, Propane & Methane. Model Number HS80004 HS80104 HS80204 HS80504 DETECTOR
Safety Siren Carbon Monoxide, Propane & Methane DETECTOR Owner's Manual Model Number HS80004 HS80104 HS80204 HS80504 Copyright, 1996 All Rights Reserved Family Safety Products, Inc. 2879 Remico SW Grandville,
More informationG-TECTA TM. Portable Gas Detection Instruments
G-TECTA TM Portable Gas Detection Instruments 2 Why Linde gas detection? The Linde Group is a global leader in the supply of gases, we provide expertise and product solutions to industry, commerce, science
More informationPortable Generator Safety Lloyd Shank, P.E. Director of Electric and Gas Utilities 4/12/2005
Portable Generator Safety Lloyd Shank, P.E. Director of Electric and Gas Utilities 4/12/2005 Page 1 of 10 Portable Generator Safety During the process of restoring electric power to a neighborhood Line
More informationDräger X-am 5000 Multi-Gas Detection
Dräger X-am 5000 Multi-Gas Detection The Dräger X-am 5000 belongs to a generation of gas detectors, developed especially for personal monitoring applications. This 1- to 5-gas detector reliably measures
More informationEssential Elements of Fire Safety
Essential Elements of Fire Safety Program Components Awareness Properties of Fire Safe Practices Human Behavior and Fire Fire Safety Systems AWARENESS Introduction Fires and explosions kill more than 200
More informationProtecting Children from Carbon Monoxide Poisoning
Protecting Children from Please click on any of the links below to go directly to your specified topic within this document. Where Should I Install Carbon Monoxide Detectors? Where Should I install Combination
More informationTIMOTHY R. SZYMANSKI Instructor
Fire & Life Safety TIMOTHY R. SZYMANSKI Instructor 44 years experience as a firefighter serving in every position from firefighter/paramedic to fire chief. Nationally and State Certified Fire & Life Safety
More informationIMR IX176 Portable Gas Detector User Manual
IMR Portable Gas Detector User Manual Read this manual carefully before using this device. (727) 328-2818 / (800) RING-IMR Fax: (727) 328-2826 www.imrusa.com Ver. 1.0A4 CONTENTS SERVICE GUIDELINES... 3
More informationRisk Management Department. Fire Extinguishers
Risk Management Department Fire 1 Introduction to Fire Every school facility is equipped with fire extinguishers for staff to use to suppress fires. Used properly, a fire extinguisher can be an effective
More informationSTANDARDS UPDATE NOTICE (SUN) ISSUED: February 16, 2018
STANDARDS UPDATE NOTICE (SUN) ISSUED: February 16, 2018 STANDARD INFORMATION Standard Number: CSA 6.19 Standard Name: Residential Carbon Monoxide Alarming Devices Standard Edition and Issue Date: 2 nd
More informationSafety Manual: Emergency Response
Safety Manual: Emergency Response January, 2017 6.0 Emergency Preparedness Introduction This Chapter provides guidelines for dealing with Emergencies. Fires, no matter how small, must be reported to management
More informationRed Alarm Indicator Light
5 Installation Instructions (cont.) Insure that all vents of the unit are unobstructed. Do not install in dead air spaces such as peaks of vaulted ceilings, or gabled roofs. Do not install in turbulent
More informationDräger X-am 5600 Personal Monitor Multi-Gas Detection Device
Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device Featuring an ergonomic design and innovative infrared sensor technology, the Dräger X-am 5600 is the smallest gas detection instrument for the
More informationMiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING
MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2 TM, and MiniClO 2 TM Responder Detectors Instruction Manual "! WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE
More informationWARRANTY. TRAK-IT IIIa
WARRANTY Your TRAK-IT IIIa is warranted to be free from defects in materials and workmanship for a period of two years after purchase (excluding calibration and batteries). The circuit board and percent
More informationMultiRAE Lite. Wireless Portable Multi-Gas Monitor
MultiRAE Lite Wireless Portable Multi-Gas Monitor The MultiRAE Lite is an optimal one-to-six 4 -gas monitoring solution for personal protection (including confined space entry) and multi-gas leak detection
More informationPROTECTING AGAINST CARBON MONOXIDE. Questions and Answers about Carbon Monoxide (CO) and CO Alarms
PROTECTING AGAINST CARBON MONOXIDE Questions and Answers about Carbon Monoxide (CO) and CO Alarms WHAT IS CARBON MONOXIDE? Carbon monoxide known by the chemical formula CO is a colorless, odorless, poisonous
More informationCarbon Monoxide Safety Information
Aurora Fire Rescue City of Aurora Fire Administration 15151 E. Alameda Parkway, Suite 4100 Aurora, Colorado 80012 303.326.8999 Worth Discovering auroragov.org Carbon Monoxide Safety Information Aurora
More informationFire Safety. Presenter, Kevin V Coleman September 14 th 2016
Fire Safety Presenter, Kevin V Coleman September 14 th 2016 Fire is a significant risk WHAT IS FIRE? To start or continue to burn, a fire requires: Heat; Fuel (Combustible materials); Oxygen. This is known
More informationToday, we re going to talk about emergency action and fire prevention. We hope we never have to face an emergency situation like a fire in our
Today, we re going to talk about emergency action and fire prevention. We hope we never have to face an emergency situation like a fire in our workplace, but we must always be prepared, just in case. Your
More informationNZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas
Page 1 of 5 Title Install fixed gas detection apparatus in hazardous areas Level 4 Credits 2 Purpose This unit standard covers the installation, calibration, and response checking of fixed gas detection
More informationCARBON MONOXIDE DETECTOR, i4h-co-m330
CARBON MONOXIDE DETECTOR, i4h-co-m330 Alarm LED Power LED Fault LED Air Vents Test/Mute Button Press the latch and push the cover downward to open the battery compartment INTRODUCTION The i4h-co-m330 electrochemical
More informationCarbon Monoxide Detectors. What is carbon monoxide?
Carbon Monoxide Detectors What is carbon monoxide? Carbon monoxide (CO) is an invisible, odorless, colorless gas created when fossil fuels (such as gasoline, wood, coal, propane, oil and methane) burn
More informationReference Manual. MultiVision Gas Detector
Reference Manual MultiVision Gas Detector Sperian Instrumentation 651 South Main Street Middletown, CT 06457 800 711-6776 860 344-1079 Fax 860 344 1068 24SEPT2008 P/N 13-230 Version 2.01 http://www.biosystems.com
More informationCarbon monoxide (CO) is a colorless, odorless gas that is the product of incomplete combustion of carbon-based fuels.
Construction Concerns: Carbon Monoxide November 20, 2017 By Gregory Havel Carbon monoxide (CO) is a colorless, odorless gas that is the product of incomplete combustion of carbon-based fuels. The chemical
More informationUsing the QRAE Plus personal multigas monitor
Using the QRAE Plus personal multigas monitor Firmware v 1.10 QRAE Plus The Hazardous Environment Detection Company QRAE Plus features Turning on the QRAE Plus Recommended Daily Start-up Procedure User
More informationGasAlertMicro 5. 1, 2, 3, 4, and 5 Gas Detectors. Quick Reference Guide
O 2, CO, H 2 S, PH 3, SO 2, Cl 2, NH 3, NO 2, HCN, ClO 2, O 3, VOC, and Combustibles 1, 2, 3, 4, and 5 Gas Detectors Quick Reference Guide Limited Warranty & Limitation of Liability BW Technologies Ltd.
More informationHOLLY HILL FIRE DEPARTMENT
HOLLY HILL FIRE DEPARTMENT Frequently Asked Questions Q. How many people work for the Fire Department? A. Holly Hill Fire Department has 14 full time and 1 part time employees. We have three shifts of
More informationDräger X-am 5000 Multi-Gas Detection
Dräger X-am 5000 Multi-Gas Detection The Dräger X-am 5000 belongs to a generation of gas detectors, developed especially for personal monitoring applications. This 1- to 5-gas detector reliably measures
More informationSalt Lake Community College FIRE EXTINGUISHER TRAINING
Salt Lake Community College Legal Basis for Training Occupational Safety and Health Administration (OSHA) Occupational Safety and Health Standards 29 CFR Part 1910 Subpart L Fire Protection Standard 1910.157
More informationRECON/4a Portable Multi-Gas Detector Operation and Maintenance Manual
680 Fairfield Court Ann Arbor, MI 48108 734.761.1270 Fax 734.761.3220 www.enmet.com RECON/4a Portable Multi-Gas Detector Operation and Maintenance Manual Table of Contents 1.0 INTRODUCTION... 2 1.1 Unpack...
More informationFIRE AND FIRE FITTING By Mr. Prashant Sansare
FIRE AND FIRE FITTING By Mr. Prashant Sansare What is mean by fire? CASE STUDY What Happened? Late one evening, a large storage tank containing a flammable liquid began to overflow. It was not detected
More informationDräger X-am 2500 Multi-Gas Detection
Dräger X-am 2500 Multi-Gas Detection The Dräger X-am 2500 was especially developed for use as personal protection. The 1 to 4 gas detector reliably detects combustible gases and vapours, as well as O2,
More informationGas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex.
Data sheet testo 317-2 / testo 316-1 / testo 316-2 / testo gas detector / testo 316-EX Gas leak detectors For a quick overview testo 317-2 testo 316-1 testo 316-2 testo gas detector testo 316-Ex CH 4 C
More information1.1 Definitions of alert icons. For your safety
For your safety 1 For your safety Before using this product, carefully read these Instructions for Use and those of the associated products. Strictly follow the Instructions for Use. The user must fully
More information