Supporting the Requirements of EPAct 2005 Tax Deductions

Size: px
Start display at page:

Download "Supporting the Requirements of EPAct 2005 Tax Deductions"

Transcription

1 Energy Saving from Greengate Supporting the Requirements of EPAct 2005 Tax Deductions

2 Energy Policy Act of 2005 Never before has the need for energy efficiency been so important, nor the benefits of energy-saving technologies greater. The U.S. government is increasing legislation to encourage the use of energy-saving technologies that conserve natural resources, have a positive impact on our environment, and ultimately save you money. History was made on Aug. 8, 2005 when the Energy Policy Act of 2005 (EPAct 2005) representing enticing tax incentives and the potential to save tens - or even hundreds - of thousands of dollars on commercial energy costs was signed into law. As a result, there has never been a better time to upgrade your commercial lighting systems with new technologies that allow you to realize the tremendous savings and tax incentive opportunities that EPAct 2005 offers. Rescue Package Extends EPAct 2005 EPAct 2005 was set to expire before Jan. 1, But the Emergency Economic Stabilization Act of 2008 (commonly called the Rescue Package) signed by President Bush on Oct. 3 extended those deductions. The Section 179D commercial building deduction taxincentive was extended for five years, through Dec. 31, Under the extension, buildings will continue to be eligible for tax deductions of 60 cents per square foot each for lighting, HVAC and the building envelope for energy reductions as compared to a building that meets ASHRAE Over the past three years, most tax deductions under EPAct have been for lighting. As thelighting industry rolls out highly energy efficient but more expensive LED (light emitting diode) lighting, the five-year extension is very timely. The Energy Policy Act of 2005 (EPAct 2005) EPAct 2005 provides a significant tax deduction to encourage the use of energy-efficient products. This government initiative will have an impact on almost all commercial buildings, both those that were built before today s energy-efficient products were available, and those planned for construction over the next few years. The Commercial Buildings Deduction of EPAct 2005 offers a special financial incentive for building owners and/or leaseholders to adopt the most energy-efficient lighting strategies. Through EPAct 2005, the owner of a commercial building can now offset the costs of new lighting systems and controls in the taxable year they are placed in service. competitiveness by investing in the highest levels of energy efficient lighting solutions and have the added benefit of deducting up to the entire expense of new interior lighting solutions in the tax year that they are placed in service. With EPAct 2005 s attractive tax incentives to address energy inefficiencies in current lighting solutions, the use of energysaving lighting technologies will pay for itself faster than ever before. Maximizing the deduction for a commercial building EPAct 2005 offers two types of tax deductions. All Systems provides a one-time whole building tax deduction of up to $1.80/square foot if you upgrade a building s 1) interior lighting system, 2) HVAC/hot water system, and 3) building envelope to obtain certification that the property surpasses the ASHRAE standard by 50% or more. A building with 100,000 square feet of applicable energy-efficient improvements, for example, would benefit from a $180,000 tax deduction under All Systems. The required 50% reduction must be accomplished solely through energy and power cost reductions for heating, cooling, ventilation, hot water and interior lighting systems. Through 2013, energy efficient lighting systems and controls may pay for themselves immediately, as well as over time, with significant tax deductions. So building owners can not only reduce operating costs, but can also increase profitability and 2

3 % of Lighting Power Density Reduction / Eligible Tax Deduction 25% 26% 27% 28% 29% 30% 31% 32% 33% 34% 35% 36% 37% 38% 39% 40% >40% $0.30 $0.32 $0.34 $0.36 $0.38 $0.40 $0.42 $0.44 $0.46 $0.48 $0.50 $0.52 $0.54 $0.56 $0.58 $0.60 $0.60 Individual Systems or Energy Saving Equipment provides a significant partial tax deduction of up to $0.60/square foot by upgrading any one of your systems to surpass the ASHRAE standard by 25-40%. Lighting is perhaps the easiest path to take advantage of the tax incentives offered by EPAct When it comes to reducing your total energy costs, no single system can have a greater impact than your lighting which can comprise up to 40% of your electricity bill (DOE/EIA). The chart shown above is a sliding scale for energy savings and corresponding tax deduction for lighting based on total LPD reduction surpassing ASHRAE standards. LPD refers to the Lighting Power Density (calculated in watts per square foot) requirements established by ASHRAE A minimum savings in lighting energy of 25% would result in a 30 cents per square foot tax deduction increasing to 60 cents for 40% or more energy savings in excess of ASHRAE In addition to lowering LPD below ASHRAE standards, EPACT 2005 also mandates additional Lighting Controls Provisions in order to qualify for the tax benefits. Estimate of Wasted Lighting in Individual Offices Daily Lighting Period Hours of Lighting Hours Wasted 8 AM 12 Noon Noon 2 PM PM 6 PM PM 12 Midnight Daily Hours % of Total Daily Hours 100% 45% These include automatic shut off, space controls, exterior lighting controls, additional controls for specialized lighting applications, and bi-level switching. When it comes to reducing your total energy costs, no single system can have a greater impact than your lighting which can comprise up to 40% of your electricity bill (DOE/EIA). The opportunity to introduce new energy-saving lighting technologies at substantial cost savings through EPAct 2005 is tremendous. According to the Department of Energy, only 20% of existing U.S. commercial buildings feature some degree of upgraded lighting technology, while 80% continue to operate lighting systems installed before Reduction in Electricity Expense When Lights are Turned Off in Unoccupied Areas Location Savings Individual Offices 40-50% Open / Partitioned Spaces 30-35% Conference Rooms 45-60% Computer Rooms 55-60% Classrooms 30-40% Restrooms 45-65% Corridors 35-50% Parking Structures 40-50% Warehouse 60-80% 3

4 Lighting Controls Lighting Controls represents a key technology for achieving EPACT 2005 requirements. While not contributing to the Lighting Power Density (LPD) savings nee ded to qualify for the Commercial Buildings Deduction, Lighting Controls such as occupancy sensors and bilevel switching are required for achieving the tax deductions of EPACT The principal lighting control provisions of ASHRAE 90.1 that must be achieved in order to qualify for the tax deductions of EPACT 2005 include automatic shut off, space controls, exterior lighting controls, and additional controls for specialized lighting. In addition, the Lighting Controls Provisions of EPACT 2005 also requires bi-level switching. Here s a review of the Lighting Controls Provisions of EPACT EPACT 2005 Mandatory Lighting Controls Provisions ASHRAE Bi-Level Switching Automatic Shut-Off Space Controls Exterior Lighting Additional Controls for Dual Level Switching Controls Specialized Lighting Applications ASHRAE Automatic Shut-Off Buildings that are larger than 5,000 square feet must use an automatic control device to turn off lighting in all spaces. The automatic control device must be either: A programmable time scheduling device, where an independent program schedule shall be provided for areas less than or equal to 25,000 square feet, but not more than one program schedule per floor, or An occupancy sensor that turns lighting off within 30 minutes after the space is vacated, or An unoccupied control signal from another control or alarm system Space Controls Each space that s enclosed by ceiling-height partitions must have at least one control device that independently controls the general lighting in the space. Each control device shall be activated either by an automatic motion sensor, or manually by an occupant. For spaces equal to or less than 10,000 square feet, each control device shall control a maximum of 2,500 square feet For spaces greater than 10,000 square feet, each control device shall control zones no larger than 10,000 square feet Each control device shall be capable of overriding the automatic lighting shut-off for no more than four hours Each control device shall be readily accessible and located so that the occupant can see lights from the controlling switch Exterior Lighting Controls Lighting for all exterior applications must be controlled by photosensor or astronomical time switch (10-hr memory retention in the event of power loss) capable of automatically turning off the exterior lighting when adequate daylight is available. Additional Controls for Specialized Lighting Applications A separate control device is required for the following specialized applications: Display/accent lighting Case lighting (lighting in cases used for display purposes) Hotel guest room lighting Task lighting (including permanently installed undershelf or undercabinet lighting) Nonvisual lighting (i.e., plant growth or food warming) Demonstration lighting (lighting equipment that is for sale or for demonstrations in lighting education) 4

5 ASHRAE Lighting Controls Requirements of EPAct 2005 Is the interior lighting in a building larger than 5,000 sq. feet? yes Will lighting be used for continuous operation? NO yes Building is exempted from mandatory automatic shut-off requirements Lighting exempted from automatic shutoff requirements Bi-Level Switching Bi-level switching must be provided for all occupancies except hotel and motel guest rooms, storage areas, restrooms, corridors and public lobbies. Lighting within a space must be switched so the occupant can reduce the connected lighting load by at least 50% in a reasonably uniform illumination pattern. Bi-level switching requirements may be met by: Switching alternate luminaires in a row or alternate rows of luminaires Separately switching half of the lamps in each luminaire or two lamps in three-lamp luminaires Using dimming controls on all lamps or luminaires NO Interior lighting in all spaces must have automatic shut-off control select one of these methods Time schedule: Independent schedule for each 25,000 sq. ft. area or each floor (such as control panel) Occupancy sensor: 30-minute maximum time delay Other system signal: Alarm system or other signal that indicates area unoccupied Provide space Control Devices For each ceiling height partitioned space Maximum controlled area is: 2,500 sq ft if space is < = 10,000 sq ft 10,000 sq ft if space is > = 10,000 sq ft Must be able to override automatic shut-off control, but not for more than four hours (not applicable to occupancy sensors) Must be accessible and located so controlled lighting is visible to the occupant There are many Lighting Control solutions available to help you meet EPACT 2005 guidelines along with ASHRAE while still achieving substantial cost savings. Wall box controls and ceiling mounted occupancy sensors are convenient, cost effective solutions to meeting these provisions while providing energy savings and quick payback to the end users. Depending upon the characteristics of the space to be controlled, energy savings as high as 90% can be realized through use of occupancy sensors alone (U.S. EPA). Bi-level switching is a way of controlling dual level lighting and can be achieved by using devices such as a dual level wall switch. Dual level wall switching uses isolated relays to allow for the separate control of two loads powered by one or two circuits. Comply with all other provisions of ASHRAE Exterior Lighting Controls Additional Controls for Specialized Lighting Applications 5

6 Greengate Solutions Greengate offers energy savings solutions that are readily available today. We offer a complete line of Lighting Control solutions that not only save energy, but also help you quickly and easily meet requirements of the Commercial Buildings Deduction of EPAct 2005, and maximize the tax deduction benefit. Greengate Ceiling Sensors Greengate Solutions for EPACT 2005 ASHRAE Bi-Level Switching Automatic Shut-Off Space Controls Exterior Lighting Controls Ceiling Mounted Occupancy Ceiling Mounted Occupancy Time-clock or with Dual Level Wall Switching Sensors Sensors a Photocell Microset Ultrasonic Designer Ceiling Sensors Designer Ceiling Sensors Warehouse Sensors Microset Ultrasonic Designer Ceiling Sensors Designer Ceiling Sensors Super Dual Tech Sensors ODC-U-1001 OMC-DT-0701-R OEF-P-2MHO-MV-S Greengate offers a complete line of Ceiling Sensors that can be used individually or in combination to provide lighting and HVAC control throughout an entire building. Greengate Ceiling Sensors utilize Ultrasonic and/or Passive Infrared (PIR) Sensing technology both engineered to provide superior performance and help maintain the proper lighting when and where it is needed. These Ceiling Sensors are ideal for reducing energy usage and costs in a variety of commercial applications such as conference rooms, public areas, corridors, restrooms, storage areas, partitioned work areas and large open spaces. Standard Ultrasonic Designer Series. These ultrasonic Sensors can be used individually or in combination to provide complete, no-gap coverage that effectively detects minor motion throughout an area. Featuring time delay adjustable from 15 seconds to 30 minutes, these designer Sensors have multiple frequencies that enable separate control of adjacent areas. Standard Designer Series Model No. Recommended Room Size Power Requirements ODC-U up to 1,000 sq. ft VDC, 25mA from ODC-U-1001-R 500 up to 1,000 sq. ft VDC, 25mA from or BAS connection ODC-U ,000 up to 2,000 sq. ft VDC, 25mA from ODC-U-2000-R 1,000 up to 2,000 sq. ft VDC. 25mA from or BAS connection ODC-U up to 500 sq. ft VDC, 25mA from ODC-U-0501-R 100 up to 500 sq. ft VDC, 25mA from or BAS connection ODC-U-0051-H 50 lin. ft VDC, 25mA from ODC-U-0051-H-R 50 lin. ft VDC, 25mA from or BAS connection ODC-U-0100-H 100 lin. ft VDC, 25mA from 6

7 MicroSet Full-Automatic Ultrasonic Designer Series. Groundbreaking MicroSet ultrasonic technology from Greengate simplifies installation. At installation, the Sensor will automatically set the time delay to 10 minutes when left at the installer test setting. The Sensor will monitor the coverage area to determine the optimum sensitivity setting and continually adjust sensitivity and time delay in response to variations in occupant behavior and environment. There is no need for the Sensor to learn behavior patterns over time. Each Sensor provides complete, no-gap coverage that effectively detects minor motion throughout the area. MicroSet Full-Automatic Designer Series Model No. Recommended Room Size Power Requirements OMC-U up to 1,000 sq. ft VDC 25mA from OMC-U1001-R 500 up to 1,000 sq. ft VDC 25mA from Greengate Switchpack or BAS connection OMC-U ,000 up to 2,000 sq. ft VDC 25mA from OMC-U-2000-R 1,000 up to 2,000 sq. ft VDC 25mA from Greengate Switchpack or BAS connection OMC-U-0501 Up to 500 sq. ft VDC 25mA from OMC-U-0501-R Up to 500 sq. ft VDC 25mA from Greengate Switchpack or BAS connection Super Dual Tech Sensor. The Super Dual Tech Sensor effectively combines passive infrared (PIR) and ultrasonic technologies for superior performance in lighting and HVAC control. This pairing of technologies virtually eliminates false activation in vacant rooms with heavy airflow. Ideal for classrooms and computer rooms, the Greengate Super Dual Tech Sensors feature self-adjusting sensitivity and time delay in real time for complete no-gap coverage. Super Dual Tech Sensor Model No. Recommended Room Size Power Requirements OMC-DT-0701-R 700 up to 2,000 sq. ft VDC 25mA from Greengate Switchpack or BAS connection OMC-DT-2000-R 300 up to 700 sq. ft VDC 25mA from Greengate Switchpack or BAS connection Warehouse Sensor. Featuring the groundbreaking MicroSet PIR technology, the Greengate Warehouse Sensor attaches and wires directly to a fluorescent fixture and controls lamps mounted up to 40 feet in a warehouse or other high bay application. No manual adjustment is necessary to sensitivity and time delay, the Sensor automatically monitors the coverage area to determine the optimum sensitivity setting and continues to self-adjust automatically and immediately in response to occupant behavior and environmental conditions. Warehouse Sensor Maximum Maximum Load Model No. Coverage Voltage Per Relay OEF-P-2MHO-MV-S 50 lin. ft. or 120 VAC: 2,000 sq. ft. Incandescent/Tungsten 6.7 amps, 800 VA Greengate Wall Switches Fluorescent/Ballast 240/277 VAC: Fluorescent/Ballast 6.7 amps, 800 VA 4.3 amps, 1200 VA SuperSwitch 2. The Greengate SuperSwitch 2 automatically turns lights off when a room is vacated, and is so smart it adjusts itself to make sure lights stay on when someone is in the room. No adjustments are necessary to sensitivity and time delay. SuperSwitch 2 can cut lighting OSW-P-0451-MV energy usage by as much as 30% during peak hours, and can save more than 90% of lighting energy used after 6 pm. The SuperSwitch 2 dual-level feature allows occupants to select a reduced level of lighting when it is more comfortable for them which can increase savings during daylight hours of up to 60%. SuperSwitch 2 Recommended Interface/ Max Model No. Room Size Voltage Load per Relay OSW-P-0451-MV Up to 300 sq. ft. 120/277 VAC 6.7 amps, 800 VA; 4.3 amps, 1200 OSW-P-0451-DMV* Up to 300 sq. ft. 120/277 VAC 6.7 amps, 800 VA; 4.3 amps, 1200 VA *Meets bi-level switching requirement. 7

8 Cost Savings Analysis Commercial Application Investment Analysis Calculation Warehouse Retrofit Comparison Meets EPACT 2005 (Controls and Lighting) 400W High-Bay Standard Fluorescent High-Bay with Metal Halide Novitas 01-36X Sensor Fixture Mounting Height 31' 31' Initial Lamp Lumens 36,000 3,100 Number of Lamps 1 6 Initial Fixture Lumens 36,000 18,600 Ballast Factor Initial Fixture Lumens (Ballast Corrected) 36,000 21,948 Lamp Lumen Depreciation Luminaire Dirt Depreciation Fixture Efficiency Maintained Fixture Lumens 18,818 17,193 Fixture Watts Fixture Lumens/Watt CRI FC Averaged Maintained Number of Fixtures Number of Greengate Occupancy Sensors 496 % Savings Using Greengate Occupancy Sensors 60% Cost per KWH $0.085 $0.085 Total Wattage 22, ,112 Square Footage 245, ,000 Total Installed Price Existing $151,366 Watts per Sq. Ft Total Hrs/Year 8,760 3,504 Annual Energy Usage (Costs) $169,888 $32,796 Energy Savings per Year N/A $137,092 Building Size: 245,000 sq. ft. (350' x 700') Total Tax Deduction (245,000 x $0.60) N/A $147,000 ASHRAE Requirement: 1.3W/sq. ft. (Warehouse Space) Deduction-$147,000 (Warehouse must exceeded ASHRAE by 50% for full.60 sq. ft. tax credit) Final Cost for Installed Job After Deduction $4, Simple Payback 0.03 Years 8

9 Office Interior New Installation Comparison 24,000 sq. ft. (25 offices ~ 4,400 sq. ft.; Meets EPACT open common areas ~ 19,600 sq. ft.) (Controls and Lighting) 3 Lamp T8 2 Lamp T5 Accord with Greengate Parabolic OSW-P-0451-DMV and OMC-U-2000 Fixture Mounting Height 10' 10' Initial Lamp Lumens 2,800 2,800 Number of Lamps 3 2 Initial Fixture Lumens 8,400 5,600 Ballast Factor Initial Fixture Lumens (Ballast Corrected) 7,560 6,440 Lamp Lumen Depreciation Luminaire Dirt Depreciation Fixture Efficiency Maintained Fixture Lumens 4,722 5,439 Fixture Watts Fixture Lumens/Watt CRI FC Averaged Maintained Number of Fixtures Number of Greengate 01-DL401 Bi-Level Switches (for private offices ~ 4,400 sq. ft.) 25 % Savings Using Greengate 01-DL401 Bi-Level Switches 55% Number of Greengate Microset Ultrasonic Ceiling Sensors (for open office areas ~ 19,600 sq. ft.) 16 % Savings Using Microset Ceiling Sensors 35% Cost per KWH $0.085 $0.085 Total Wattage 19,836 13,068 Square Footage 124,000 sq. ft. (25 offices ~ 4,400 sq. ft.; 24,000 24,000 4 open common areas ~ 19,600 sq. ft.) Total Installed Price $18,012 $35,353 Watts per Sq Ft Total Hrs/Year for private offices 4,380 1,971 Total Hrs/Year for open office areas 4,380 2,847 Annual Energy Usage (Costs) $7,385 $2,984 Annual Energy Savings per Year N/A $4,401 Building Size: 24,000 sq. ft. (120' x 200') Total Tax Deduction (24,000 x $0.60) $14,400 ASHRAE Requirement: 1.3W/sq. ft. (Office Space) Deduction: -$14,000 Final Cost for Installed Job After Deduction $18,012 $20,953 9

10 Additional Information Frequently Asked Questions What commercial projects are eligible for EPAct 2005 deductions? Projects eligible under the energy-efficient commercial building tax deduction of EPAct 2005 are those: 1. Located within the United States 2. Within the scope of ASHRAE (includes public buildings, schools and rental housing four stories or higher) 3. Utilize energy efficient commercial building property installed as part of the interior lighting system, HVAC/hot water system, or building envelope 4. Placed in service between Jan. 1, 2006 and Dec. 31, 2013 Lighting system projects may qualify for the partial deduction if they satisfy the following requirements: 1. Reduce lighting power density (LPD) by 25-40% beyond ASHRAE minimum requirements (warehouse spaces must reduce LPD by 50%) 2. Comply with all ASHRAE lighting controls requirements 3. Provide bi-level switching for all occupancies (except hotel/motel guest rooms, store rooms, restrooms and public lobbies) 4. Minimum requirements for calculated lighting levels according to IESNA Lighting Handbook, 9th Ed. EPAct 2005 is very confusing to read. How complicated is this? What s important to understand is that the lighting portion of the Commercial Buildings Deduction can be achieved by using commercially available lighting technologies, good lighting design, and familiar lighting practices aimed at exceeding the minimum requirements of ASHRAE , the national standard energy code. Even if I meet the LPD deduction requirement of EPACT 2005, do I still have to meet the Lighting Controls and Bi- Level Switching Provisions of ASHRAE in order to receive any tax deduction? Yes. Regardless of how much energy-savings you are able to obtain in your lighting system through reduced LPD, you must also meet the Lighting Controls Provisions of ASHRAE and Bi-Level Switching Requirements. Does the accelerated tax deduction cover the complete cost of the lighting and controls, including installation labor, or does it only include the cost of purchasing the equipment? What are thecomponents of the cost that can be written off? It includes anything that can be capitalized, including the cost of labor. Are recycling costs deductible? Any cost that may be capitalized may be considered for the deduction. What is the difference between a tax deduction and a tax credit? The difference between a deduction and a credit is that a credit reduces the tax, while a deduction reduces the amount of income that is taxed. A tax deduction is subtracted from your adjusted gross income before you calculate your federal income taxes. A "tax credit" entitles the taxpayer to subtract the amount of the credit (dollar-for-dollar) from the total federal income tax bill. 10

11 Who gets the deduction? The tax deduction for privately-owned buildings goes to the owner or the person or entity who paid to have the building constructed or renovated. For government buildings, the primary designer of the lighting system typically can claim the deduction in the owner s place. Can one benefit from the tax credit if improvements are only made to part of a building instead of the entire building? Yes, EPAct 2005 encourages tenants or occupants of a building to utilize energy-efficient equipment, as well as building owners. Tax deductions can be claimed by an owner or tenant for energy-efficiency equipping a portion of a building, as long as the improvements meet all of the ASHRAE 90.1 requirements. In fact, two or more tenants in the same building can claim a tax deduction as long as the total of the deductions does not exceed the amount allowed for the building as a whole. How do I claim the Energy Efficiency tax deduction for Commercial Property Owners? The IRS has unveiled guidelines on how commercial building owners or leaseholders can qualify for the tax deduction for making their building energy efficient, as well as the official process to certify the required energy savings in order to claim the Energy Efficiency Deduction. While the amount deductible may be as much as $1.80 per square foot of building floor area for buildings that achieve a 50% energy savings target, buildings below the 50% threshold may qualify for a deduction of up to 60 cents per square foot if they meet a 16.7% energy savings target. EPAct 2005 instructs the Secretary of the Treasury to modify its tax forms so that the Commercial Buildings Deduction can be implemented. Building owners and managers, and electrical and lighting professionals are encouraged to see the consultation of a tax expert. Does compliance have to be verified? Yes, before claiming the deduction with respect to equipment installed on or in a commercial building, the taxpayer must obtain a certification with respect to the property. This certification must be provided by a qualified individual and satisfy the requirements of 179D of the Internal Revenue Code. Third-party inspectors who review the plans and actual construction/renovation will determine whether or not compliance has been met. Procedures for the inspection and testing of buildings will be determined by the Secretary of the Treasury. Details of the certification requirements can be found in IRS Notice Deduction for Energy Efficient Commercial Buildings. What is the effective date for taking advantage of this tax deduction? The provision is effective for energy-efficient commercial building property placed in service after December 31, 2005 and prior to January 1, 2014 and the deduction will only be allowed in the year that the energy-saving solutions are placed in service. EPACT 2005 Resources Advanced Energy Design Guide for Small Office Buildings available at 11

12 North America Headquarters 203 Cooper Circle Peachtree City, GA P: F: Service & Support Center 6 Green Tree Drive South Burlington, VT P: F: International Headquarters 26 Greenhill Crescent Watford Business Park Watford, Herts, WD18 8XG. UK P: +44 (0) F: +44 (0) enquiries@coopercontrols.co.uk + = Greengate Since 1977 Industry Leading Technology Occupancy Controls 500,000 + Installations Since 1982 Outstanding Service Relay Panels 30,000 + Installations Complete Energy Management Offering One Company, One Phone Number to Call World Class Engineering/Manufacturing/Quality Cooper Industries, Ltd. 600 Travis, Ste Houston, TX P: Cooper Controls, Greengate, Novitas, PCI Lighting Controls, MicroSet, Digita, ControlKeeper, LiteKeeper, DMX Keeper, AnalogKeeper, IntelliRelay are valuable trademarks of Cooper Industries in the U.S and other countries. You are not permitted to use Cooper Trademarks without the prior written consent of Cooper Industries. ACC Printed in U.S.A.

A Guide to the Commercial Building Tax Deduction. Effective: January 1, 2006 to December 31, 2008 HL /07

A Guide to the Commercial Building Tax Deduction. Effective: January 1, 2006 to December 31, 2008 HL /07 A Guide to the Commercial Building Tax Deduction Effective: January 1, 2006 to December 31, 2008 HL-2242 2/07 The H.R. 6, Energy Policy Act of 2005 was signed into law on August 8, 2005. (Opportunity expires

More information

A Guide for Applicants and Lighting Designers

A Guide for Applicants and Lighting Designers Sustainable Office Design Program: A Guide for Applicants and Lighting Designers Inside this Guide: Introduction... 2 Organize Your Space... 3 Select Lighting Solutions... 4 Select Controls... 5 Open Offices...

More information

0ACDT2000MV Ultasonic/Infared Occ Sensor

0ACDT2000MV Ultasonic/Infared Occ Sensor 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 0ACDT2000MV Ultasonic/Infared Occ Sensor Eaton Lighting Catalog Number 0ACDT2000MV Manufacturer Eaton Lighting Description

More information

Lighting Control Strategies. to meet code requirements save energy and improve building performance

Lighting Control Strategies. to meet code requirements save energy and improve building performance Lighting Control Strategies to meet code requirements save energy and improve building performance 1 Lighting Control Strategies Agenda Why Lighting Control Manual Light Reduction Scheduling Occupancy

More information

Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013

Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013 WHITE PAPER Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard 90.1-2010 & 2013 JUNE 2016 DT213 (Rev.10.2.17) Executive Summary ASHRAE Standard 90.1 is developed with the Illuminating Engineering

More information

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1) MANDATORY MEASURES INDOOR LIGHTING CONTROLS (Reference: Sub-Chapter 4, Section 130.1) MANDATORY LIGHTING CONTROLS 1. Area Controls: Manual controls that control lighting in each area separately 2. Multi-level

More information

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1 Occupancy and Vacancy Sensors ENERLITES offers a wide variety of lighting sensors. They are designed to bring convenience to your life and business while helping to reduce energy consumption in commercial,

More information

ASHRAE October 18, 2013

ASHRAE October 18, 2013 ASHRAE 90.1 2010 October 18, 2013 Energy Consumption Buildings consume 40% of the primary energy and 71% of the electrical energy in the US. Driven by economic expansion and population growth that require

More information

WSA120: New Energy Codes and Lighting Controls

WSA120: New Energy Codes and Lighting Controls WSA120: New Energy Codes and Lighting Controls Member Since 2003 1.0 AIA/CES Learning Units (HSW) Partner Since 1998 Brought to you by WattStopper Today s Presenter: Joe McGrath www.wattstopper.com Learning

More information

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is. Energy Conservation Code Commercial Electric CHAPTER 5 WORKSHEET 1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is. a.

More information

MANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately

MANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately MANDATORY MEASURES INDOOR LIGHTING CONTROLS (Reference: Sub-Chapter 4, Section 130.1) MANDATORY LIGHTING CONTROLS 1. 130.1 (a) Area Controls: Manual controls that control lighting in each area separately

More information

AHAC-DT MicroSet dual tech low/line voltage ceiling sensors

AHAC-DT MicroSet dual tech low/line voltage ceiling sensors s Ceiling sensors description The dual technology sensor s combination of ultrasonic and passive infrared technologies offers the most complete sensing equipment available today. MicroSet self-adjusting

More information

TITLE 24 ICONOGRAPHY. Iconography System

TITLE 24 ICONOGRAPHY. Iconography System TITLE 24 ICONOGRAPHY Iconography System The icons symbolize specific language found in the code requirements. They represent product and space characteristics. Icons not only represent the requirements

More information

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130)

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130) MANDATORY MEASURES INDOOR LIGHTING CONTROLS (Reference: Sub-Chapter 4, Section 130) MANDATORY LIGHTING CONTROLS 1. Area Controls: Manual controls that control lighting in each area separately 2. Multi-level

More information

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations Eaton s Arrow Hart Commercial lighting controls Eaton s Arrow Hart Universal Dimmers and Sensors Reliable lighting control for commercial installations Arrow Hart Eaton s s and dimmers are cost -effective

More information

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5 Sensor Buying Guide Table of Contents Sensor Models 2 Advantages of Sensors 3 FAQs 4-5 Occupancy and Vacancy Sensors, which provide automatic switching of lighting and motor loads, are fast becoming a

More information

California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings

California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings A Title 24 Code Review for Electrical Professionals By: Brian Friedel LEED AP brian.friedel@wattstopper.com

More information

InvestSmart Business Energy Upgrades Lighting Equipment Catalog 01/01/2018

InvestSmart Business Energy Upgrades Lighting Equipment Catalog 01/01/2018 2018 InvestSmart Business Energy Upgrades 01/01/2018 Table of Contents 1 Lighting Improvement Measures...1-1 1.1 Lighting... 1-1 1.2 Occupancy Sensors... 1-3 1 Lighting Improvement Measures This Equipment

More information

Never forget to turn the lights off again. Motion Sensors

Never forget to turn the lights off again. Motion Sensors Never forget to turn the lights off again. Motion Sensors by Why use motion sensors? Motion Sensors Everyone knows that you can save energy by turning off lights when they re not being used. Even so, sometimes

More information

Advances in Non-Residential Lighting Technologies

Advances in Non-Residential Lighting Technologies Advances in Non-Residential Lighting Technologies CABEC conference San Diego, CA October 21, 2011 Steven Mesh, LC, IESNA Lighting Education & Design 140 Gardenside Drive, #304 San Francisco, CA 94131 415-516-8126

More information

SECTION LIGHTING CONTROL DEVICES EATON S LIGHTING SYSTEMS (FORMERLY COOPER CONTROLS) VACANCY/OCCUPANCY SENSORS

SECTION LIGHTING CONTROL DEVICES EATON S LIGHTING SYSTEMS (FORMERLY COOPER CONTROLS) VACANCY/OCCUPANCY SENSORS SECTION 260923 LIGHTING CONTROL DEVICES EATON S LIGHTING SYSTEMS (FORMERLY COOPER CONTROLS) VACANCY/OCCUPANCY SENSORS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Wall box mounted, wall/corner

More information

NEW ENHANCED CAPITAL ALLOWANCE EXPLAINED NEW ECA EXPLAINED HELEN LOOMES 2013/2014 SLL MASTERCLASS

NEW ENHANCED CAPITAL ALLOWANCE EXPLAINED NEW ECA EXPLAINED HELEN LOOMES 2013/2014 SLL MASTERCLASS NEW ENHANCED CAPITAL ALLOWANCE EXPLAINED NEW ENHANCED CAPITAL ALLOWANCE EXPLAINED The benefits and new requirements of the scheme The additional benefits of using energy efficient schemes. How to overcome

More information

Shannon J Markey LC, LEED AP Legrand BCS / Wattstopper Western Regional Manager. Yesterday, Today & Tomorrow

Shannon J Markey LC, LEED AP Legrand BCS / Wattstopper Western Regional Manager. Yesterday, Today & Tomorrow Shannon J Markey LC, LEED AP Legrand BCS / Wattstopper Western Regional Manager Yesterday, Today & Tomorrow The Good Old Days: The.59 Cent Solution Simple, Inexpensive, Easy To Operate, Etc. Everybody

More information

CL001 >400 Watt lamp basecase, up to 600 Watt replacement fixture $95.00 Fixture

CL001 >400 Watt lamp basecase, up to 600 Watt replacement fixture $95.00 Fixture Lighting Specifications Business Please read the details below to ensure you are installing a qualifying product(s). An MID inspection of the pre-existing lighting scheme is required prior to the installation

More information

Code Review TITLE PRESENTED BY POURIA NIKNAM

Code Review TITLE PRESENTED BY POURIA NIKNAM Code Review TITLE 24-2016 PRESENTED BY POURIA NIKNAM 2 Important Topics Partial-On as per Title 24 Definition and criteria for Daylight Responsive Control Controlled Receptacles Automatic Demand Response

More information

High Performance Lighting. Terry Egnor Senior Consultant NBI

High Performance Lighting. Terry Egnor Senior Consultant NBI High Performance Lighting Terry Egnor Senior Consultant NBI Design Issues Energy Efficiency is not difficult Lighting Quality is not difficult Together, it is a challenge GOAL: Energy Effective Lighting

More information

Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE

Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE Guides for California Title 24 & ASHRAE Code Compliance Lightcloud Makes Compliance Easy What are California Title 24 & ASHRAE? Links to Energy Codes Interior Lighting Controls Exterior Lighting Controls

More information

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1) MANDATORY MEASURES INDOOR LIGHTING CONTROLS (Reference: Sub-Chapter 4, Section 130.1) MANDATORY LIGHTING CONTROLS 1. 130.1 (a) Area Controls: Manual controls that control lighting in each area separately

More information

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor TECHNICAL SPECIFICATIONS PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor Basic Features Line voltage version: 120-277VAC, 60Hz Low voltage version: 24VDC, requires separate class 2 power supply PIR sensor

More information

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section Wiring Devices for wall-box dimmers and manual light switches. PART 1 - GENERAL... 1 1.1 RELATED DOCUMENTS... 1 1.2 SUMMARY... 1 1.3 REFERENCES... 2 1.4 DEFINITIONS... 2 1.5 SUBMITTALS... 2 1.6 QUALITY ASSURANCE... 3 1.7 COORDINATION... 3 1.8 DELIVERY, STORAGE, AND

More information

Aesthetic, energyefficient. control solutions for hospitality facilities QUICK GUIDE TO LIGHTING CONTROL FOR HOTELS

Aesthetic, energyefficient. control solutions for hospitality facilities QUICK GUIDE TO LIGHTING CONTROL FOR HOTELS Aesthetic, energyefficient lighting control solutions for hospitality facilities QUICK GUIDE TO LIGHTING CONTROL FOR HOTELS Table of Contents Introduction 3 Guest room 4-5 Guest bathroom 6-7 Public areas

More information

Lighting Controls: The Next Big Thing in Lighting. June 18th, 2014

Lighting Controls: The Next Big Thing in Lighting. June 18th, 2014 Lighting Controls: The Next Big Thing in Lighting June 18th, 2014 Meet Your Panelists: Mike Carter Sr. Engineer, CEM Kandice Cohen New Business Development Manager Consumers Energy Subject Matter Experts:

More information

Are LED s ready for Prime Time?

Are LED s ready for Prime Time? Tracy Beattie, LC, CLMC has been in the lighting industry since 1988. He was Lighting Certified by NCQLP in December 2013. He worked for a lighting distributor in the LA market until 2010 when he partnered

More information

Reduce lighting energy costs with controls

Reduce lighting energy costs with controls Reduce lighting energy costs with controls Reduce energy costs. Support sustainability Get control of your lighting. Upgrading lighting systems to next-generation lighting technologies can deliver energy

More information

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is. 2018 NC Energy Conservation Code Commercial Electrical Module 5 CHAPTER 4 [CE] WORKSHEET 1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the

More information

Applied Lighting Controls

Applied Lighting Controls Better Buildings By Design 2010 Applied Lighting Controls Steven Mesh, LC, IESNA Senior Lighting Program Coordinator Pacific Energy Center (Pacific Gas & Electric) 851 Howard Street, San Francisco, CA

More information

A. This Section includes the following lighting control devices:

A. This Section includes the following lighting control devices: Attachment G LIGHTING CONTROL SPECIFICATIONS (Download Document separately) LIGHTING CONTROL SPECIFICATIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including

More information

Here we see the list of auto shutoff controls we will cover in the next few slides

Here we see the list of auto shutoff controls we will cover in the next few slides Here we see the list of auto shutoff controls we will cover in the next few slides 22 All installed indoor lighting: Shall be controlled with an occupant sensing control, automatic time switch control,

More information

The Power To Supply... All Your Electrical Products

The Power To Supply... All Your Electrical Products ENERGY EFFICIENT RETROFIT SOLUTIONS The Power To Supply... All Your Electrical Products www.cef.co.uk All products are subject to availability and are correct at the time of print. Errors and omissions

More information

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations Eaton s Arrow Hart Commercial lighting controls Eaton s Arrow Hart Universal Dimmers and Sensors Reliable lighting control for commercial installations Arrow Hart Eaton s sensors and dimmers are cost -effective

More information

Lighting Control Solutions for Parking Facilities

Lighting Control Solutions for Parking Facilities Lighting Control Solutions for Parking Facilities Control Safety, Connect Strategies, and Commission Zones Parking Lighting Strategies for Optimal Performance Historically, parking garage lighting was

More information

HUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004

HUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004 HUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004 EPA Green Lights A L L Y USE OF THIS LOGO DOES NOT IMPLY EPA ENDORSEMENT APRIL 2008 www.nsiindustries.com E-mail: nsi@nsiindustries.com Fax:

More information

Incentive & Measure Specifications

Incentive & Measure Specifications Incentive & Measure Specifications Commercial Energy Solutions EasySave Program Prescriptive Incentives RETROFIT LIGHTING Incandescent to LED Lighting T12/T8 Fluorescent Tubes to LED Tubes HID to LED Fixtures

More information

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5 Page 1 of 5 1.0 GENERAL 1.1 Related UBC Guidelines.1 Section 27 05 05 Communication Rooms Design Guidelines 2.13 1.2 Coordination Requirements.1 UBC Energy & Water Services.2 UBC Building Operations Electrical

More information

Wireless Plug Load Control

Wireless Plug Load Control General Specification Wireless Plug Load Control Model No.: PL20R & PLBPC Description:Enerlites Wireless Plug Load Controller is designed with simplicity, and helps to make plug load control requirements

More information

Lighting Summary - Interior

Lighting Summary - Interior Lighting Summary - Interior LTG-SUM Project Info Date: For Building Department Use Applicant Name: Applicant Address: Applicant Phone: Project Description F New building Addition Alteration Compliance

More information

FROM THE WORLD S FIRST GFCI RECEPTACLE TO OUR GAME-CHANGING LINE OF PASS & SEYMOUR PLUGTAIL DEVICES, PASS & SEYMOUR PRODUCTS HAVE A REPUTATION FOR

FROM THE WORLD S FIRST GFCI RECEPTACLE TO OUR GAME-CHANGING LINE OF PASS & SEYMOUR PLUGTAIL DEVICES, PASS & SEYMOUR PRODUCTS HAVE A REPUTATION FOR FROM THE WORLD S FIRST GFCI RECEPTACLE TO OUR GAME-CHANGING LINE OF PASS & SEYMOUR PLUGTAIL DEVICES, PASS & SEYMOUR PRODUCTS HAVE A REPUTATION FOR INNOVATION AND RELIABILITY THAT SPANS OVER 120 YEARS.

More information

Energy Management. Lighting Control Solutions. To create flexible lighting networks

Energy Management. Lighting Control Solutions. To create flexible lighting networks Energy Management Lighting Control Solutions To create flexible lighting networks Greengate by Cooper Controls Offices Public Spaces Airports Stations Shopping Centres Libraries About Cooper Controls Cooper

More information

LIGHTING CONTROLS

LIGHTING CONTROLS 260923 LIGHTING CONTROLS PART 1: GENERAL 1.01 SUMMARY COMMENTS A. CU has developed this lighting control guideline to direct design professionals toward standard solutions that meet the University s performance

More information

Versatile wall switch sensors maximize payback and simplify code compliance

Versatile wall switch sensors maximize payback and simplify code compliance Versatile wall switch sensors maximize payback and simplify code compliance Commercial Wall Switch Occupancy Sensors MANUAL-ON MULTI-WAY NIGHTLIGHT Achieve the best energy savings for every wall switch

More information

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification Dual Technology Wall Mounted Occupancy Sensor Manual & Specification PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES Douglas Lighting Controls Page 1 December 16, 2013 1. INTRODUCTION

More information

Wireless Lighting Control Made Easy

Wireless Lighting Control Made Easy Wireless Lighting Control Made Easy Wireless Lighting Control Made Easy David Orband Crestron Electronics This session is eligible for 1 Contact Hour. For these hours to appear on your certificate, you

More information

PRESCRIPTIVE APPROACH

PRESCRIPTIVE APPROACH PRESCRIPTIVE APPROACH 1. Actual and Allowed LPD 2. Complete Building Method 3. Area Category Method 4. Tailored Method This section contains exercises for lighting power adjustments, Complete Building

More information

A. This Section includes the following lighting control devices:

A. This Section includes the following lighting control devices: SECTION 26 09 23 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Advanced Lighting For Office

Advanced Lighting For Office Advanced Lighting For Office Open-Plan Office Applications High-Density 1 This High-Density 1 lighting application module presents alternative energy effective lighting design options for open-plan offices.

More information

AERS. Automatic Energy Reduction System HID lamp control systems for maximum energy savings

AERS. Automatic Energy Reduction System HID lamp control systems for maximum energy savings AERS Automatic Energy Reduction System HID lamp control systems for maximum energy savings Holophane has been a leader in energy efficient luminaires and systems for over 100 years. In the late 1960 s,

More information

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2 Passive Infrared Sensors (PIR) Using a patented fresnel lens which minimizes optical aberrations, each Legrand/Pass & Seymour PIR sensor breaks its coverage area into zones. Upon detecting an infrared

More information

Advanced Lighting Solutions

Advanced Lighting Solutions Advanced Lighting Solutions Ben Koyle, LC, LEED Green Assoc. April 20, 2017 Learning Objective Gain a better understanding of the energy savings potential of LED luminaires and networked lighting control

More information

Note: A summary of the applicable code sections is shown in the CEC _Table100A.

Note: A summary of the applicable code sections is shown in the CEC _Table100A. CALIFORNIA ENERGY COMMISSION 2016 Building Energy Efficiency Standards California Code of Regulations, Title 24, Part 6 Non-Residential Lighting Requirements Summary 3/27/2018 Scope: The California Title

More information

Hospitality Title Solutions

Hospitality Title Solutions Hospitality Solutions Design Guide Crestron Electronics, Inc. Contents About 1 Design Guide Information 1 Code Standards 2 Guest Room 4 Zūm... 4 Guest Room Suite 5 Zūm... 5 Lobby 6 Zūm... 6 GLPP... 7 GLPAC

More information

IN2 Lighting Control Devices

IN2 Lighting Control Devices Illinois Math and Science Academy DigitalCommons@IMSA Project Manuals IN2 2015 IN2 Lighting Control Devices Illinois Mathematics and Science Academy Follow this and additional works at: http://digitalcommons.imsa.edu/facility_in2_manuals

More information

Mini Product Guide.

Mini Product Guide. Mini Product Guide www.acuitybrands.com/sensorswitch Better Performance Through Advanced Technology 100% Digital Passive Infrared (PIR) Detection Dual Technology Detection utilizing Microphonics Contractor

More information

LIGHTING CONTROL DEVICES

LIGHTING CONTROL DEVICES SECTION - PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this

More information

Time Warner Center at Columbus Circle, the home of Related s offices. Credit: Green Light New York

Time Warner Center at Columbus Circle, the home of Related s offices. Credit: Green Light New York case study Related Companies Office Lighting Retrofit A complicated, after-hours lighting retrofit that greatly improved the office environment, reduced lighting energy use by 56% and shaved peak demand

More information

Princeton Joint Unified School District Invitation for Bid Installation of District-Wide Lighting Occupancy Sensors

Princeton Joint Unified School District Invitation for Bid Installation of District-Wide Lighting Occupancy Sensors Princeton Joint Unified School District Invitation for Bid Installation of District-Wide Lighting Occupancy Sensors 1. SUMMARY AND BACKGROUND: Princeton Joint Unified School District located in Princeton

More information

INSPECTION REQUIREMENTS: ENERGY CODE LIGHTING & ELECTRICAL NON-RESIDENTIAL

INSPECTION REQUIREMENTS: ENERGY CODE LIGHTING & ELECTRICAL NON-RESIDENTIAL Energy Code Lighting & Electrical Non-Residential Page 1 of 14 Revision Date: 2/12/2018 INSPECTION REQUIREMENTS: ENERGY CODE LIGHTING & ELECTRICAL NON-RESIDENTIAL INSPECTION CODE: N/A SCOPE: NON-RESIDENTIAL,

More information

Oregon Non-Residential Building Energy Code

Oregon Non-Residential Building Energy Code Oregon Non-Residential Building Energy Code Interior Connected Lighting Power Requirements The requirements for interior lighting power are one of the most important sections of the Oregon Energy Code.

More information

Sensors and Detectors

Sensors and Detectors 12/12/2017 Sensors and Detectors - Clipsal by Schneider Electric Sensors and Detectors Add sensors and detectors to make an environment smarter and more efficient. C-Bus sensors and detectors allow environmental

More information

Richmond Building Energy Challenge. Project List - Lighting Technologies

Richmond Building Energy Challenge. Project List - Lighting Technologies Richmond Building Energy Challenge Project List - Lighting Technologies Introductions Adam Franklin, LEED Green Associate, Electrical Engineer (EIT) Adam is involved in carrying out the electrical aspects

More information

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

CS1200 WHT Pir Ceiling Mount Occupancy Sensor 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category Features Area Coverage Field of View Load Type

More information

Room Controller System Overview

Room Controller System Overview Quick Connection Cable Pre-Programmed Relay Control Eliminate wiring errors with quick connection RJ45 cable. Satisfy code compliance upon system power up. Receptacle Control (Required by ASHRAE 90.1-2010)

More information

California Title Design Guide for Smart Lighting Control and Energy Solutions

California Title Design Guide for Smart Lighting Control and Energy Solutions California Title 24 206 Design Guide for Smart Lighting Control and Energy Solutions Leviton Excellence for Title 24 Standards California Title 24 206 provides the minimum requirements for energy-efficient

More information

2017 Lighting Incentive

2017 Lighting Incentive Commercial & Industrial Retrofit 2017 Lighting Section A: CUSTOMER INFORMATION Customer Name Electric Account Number Rate Application Number Facility Address City State Zip Service Location Identification

More information

Office Title Solutions

Office Title Solutions Office Title 24-2016 Solutions Design Guide Crestron Electronics, Inc. Contents About Title 24-2016 1 Design Guide Information 1 Title 24-2016 Code Standards 2 Private Office Space / Huddle Space 4 Zūm...

More information

Dual Relay Multi-Technology Wall Switch Occupancy Sensors

Dual Relay Multi-Technology Wall Switch Occupancy Sensors Dual Relay Multi-Technology Wall Switch Occupancy Sensors The OSSMD line of dual relay multi-technology Decora style wall switch occupancy sensors features several models to provide automatic lighting

More information

Philips Lighting North America Corporation 200 Franklin Square Drive Somerset, NJ Tel

Philips Lighting North America Corporation 200 Franklin Square Drive Somerset, NJ Tel 2015 Koninklijke Philips N.V. All rights reserved. Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be

More information

Related Sections: TBD. Effective Date: January 1, 2016

Related Sections: TBD. Effective Date: January 1, 2016 Description: The purpose of the section is to highlight the current applicable UMCP Design Standards for the design, selection and, installation of lighting fixtures within buildings. Related Sections:

More information

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) LTG-1-A

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) LTG-1-A 2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) LTG-1-A PROJECT ADDRESS TESTING AUTHORITY TELEPHONE Checked by/date Enforcement Agency Use GENERAL INFORMATION OF BLDG. PERMIT PERMIT # BLDG. CONDITIONED FLOOR

More information

SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1

SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1 SENSORS ENERLITES offers a wide variety of Occupancy and Vacancy sensor models that can monitor virtually any area within a building. We cover the spectrum of technologies with our passive infrared, basic

More information

Energy Codes. Connected Lighting simplified by Eaton. design and application guide

Energy Codes. Connected Lighting simplified by Eaton. design and application guide Codes Connected simplified by Eaton design and application guide We make connections work* Eaton Power Connectivity Apps * Simplif ied connected lighting solutions for Buildings, Communities & omes Eaton

More information

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDHS-AD-LT30 Ceiling PIR HS presence detector 1-10V, low temperature Overview The EBDHS-AD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads with

More information

Advances in Lighting Controls and the Impact of ASHRAE Requirements. Rich Rattray, LC OSRAM SYLVANIA

Advances in Lighting Controls and the Impact of ASHRAE Requirements. Rich Rattray, LC OSRAM SYLVANIA Advances in Lighting Controls and the Impact of ASHRAE Requirements Rich Rattray, LC OSRAM SYLVANIA Click Addressable to edit Master Lighting title Controls style What are Addressable Lighting Controls?

More information

What You Need to Know About California Compliance T20, T24 and JA8 Chris Primous VP OEM National Accts and Industry Relations April 18, 2018

What You Need to Know About California Compliance T20, T24 and JA8 Chris Primous VP OEM National Accts and Industry Relations April 18, 2018 What You Need to Know About California Compliance T20, T24 and JA8 Chris Primous VP OEM National Accts and Industry Relations April 18, 2018 WHAT YOU NEED TO KNOW ABOUT CALIFORNIA COMPLIANCE T20, T24,

More information

The Power To Supply... All Your Electrical Products

The Power To Supply... All Your Electrical Products May 2016 ENERGY EFFICIENT RETROFIT SOLUTIONS The Power To Supply... All Your Electrical Products www.cef.co.uk All products are subject to availability and are correct at the time of print. Errors and

More information

Ever evolving energy code requirements and the large demand for energy

Ever evolving energy code requirements and the large demand for energy Ever evolving energy code requirements and the large demand for energy saving products have made lighting control sensors a must-have for building owners and managers. Hubbell Control Solutions introduces

More information

COMcheck Software Version Interior Lighting Compliance Certificate

COMcheck Software Version Interior Lighting Compliance Certificate Section 1: Project Information Energy Code: 2009 IECC Project Type: New Construction COMcheck Software Version 4.0.2.8 Interior Lighting Compliance Certificate Construction Site: Owner/Agent: Designer/Contractor:

More information

H-MoSS. Tomorrow s Technology Today! H-MOSS Occupancy and Vacancy Sensors. Adaptive Technology Dual Technology Ultrasonic Passive Infrared

H-MoSS. Tomorrow s Technology Today! H-MOSS Occupancy and Vacancy Sensors. Adaptive Technology Dual Technology Ultrasonic Passive Infrared H-MOSS Occupancy and Vacancy Sensors H-MoSS Hubbell Motion Sensing Switches Tomorrow s Technology Today! Adaptive Technology Dual Technology Ultrasonic Technology for Today s Needs Dual Technology H-MOSS

More information

2018 Commercial Lighting Retrofit Rebate Program

2018 Commercial Lighting Retrofit Rebate Program 2018 Commercial Lighting Retrofit Rebate Program HOW TO APPLY 1. AMU provides energy efficiency rebates for the purchase and installation of qualifying lighting equipment. Additional lighting rebates,

More information

DHL-LP-LED Low Profile LED Linear High/Low Bay

DHL-LP-LED Low Profile LED Linear High/Low Bay Job Information Type: Catalog #: Project: Comments: Prepared by: WARRANTY WARRANTY YEAR TEN INCLUDES LABOR ALLOWANCE 2 65W/90W Version 23.81 2 135W Version For 4 dimensions see pg 2 23.81 23.81 23.81 12.6

More information

LightSweep. Lighting Control System

LightSweep. Lighting Control System LightSweep Lighting Control System Incredible Control GE LightSweep is a comprehensive indoor lighting control system designed to save money while improving the efficiency, comfort, safety and security

More information

Pacific Gas and Electric Company Energy Efficiency Rebates for Your Business. Lighting Rebate Catalog Saving energy for a brighter future

Pacific Gas and Electric Company Energy Efficiency Rebates for Your Business. Lighting Rebate Catalog Saving energy for a brighter future Pacific Gas and Electric Company Energy Efficiency Rebates for Your Business Lighting Rebate Catalog Saving energy for a brighter future Customers may be eligible to participate in Pacific Gas and Electric

More information

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 26 ELECTRICAL

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 26 ELECTRICAL 265100 INTERIOR LIGHTING PART 1 - GENERAL 1.1. Any deviation from the following instructions must be approved during design by WVU Facilities Management Personnel. 1.2. DEFINITIONS A. AHJ Authority Having

More information

Healthcare Title Solutions

Healthcare Title Solutions Healthcare Solutions Design Guide Crestron Electronics, Inc. Contents About 1 Design Guide Information 1 Code Standards 2 Operating Room 4 GLDALI... 4 GLPAC... 5 Patient Room / Exam Room 6 GLDALI... 6

More information

2017 Commercial & Industrial Program C&I Lighting Prescriptive Rebate Application

2017 Commercial & Industrial Program C&I Lighting Prescriptive Rebate Application MEMBER INFORMATION Member Name Company Name Mailing Address City State ZIP Phone Email Electric Cooperative/REMC Name (MUST be completed) Electric Cooperative/REMC Account Number (MUST be completed) Check

More information

visual environment technologies etcconnect.com

visual environment technologies etcconnect.com visual environment technologies etcconnect.com About ETC ETC is a global leader in the manufacture of award-winning lighting-control systems, backed by our renowned /7/65 support. ETC offers complete solutions

More information

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE: THE HIGH PERFORMANCE LED Luminaire Series for Stairwells, Bathrooms, Passageways, and General Illumination KEY FEATURES INCLUDE: Multiple Color Options Three color options ensure that the new lighting

More information

C A L I F O R N I A E N E R G Y C O M M I S S I O N

C A L I F O R N I A E N E R G Y C O M M I S S I O N C A L I F O R N I A E N E R G Y C O M M I S S I O N 38 Lighting Acceptance/Installation Cert. 2008 134 2013 130.4 Testing mandatory if controls/systems installed for: Multi-level controls Shut-off controls

More information

Hubbell Controls Application Guide to ASHRAE 90.1 A SUPPLEMENTAL GUIDE TO CODE REVISIONS IMPACTING LIGHTING CONTROL

Hubbell Controls Application Guide to ASHRAE 90.1 A SUPPLEMENTAL GUIDE TO CODE REVISIONS IMPACTING LIGHTING CONTROL Hubbell Controls Application Guide to ASHRAE 90.1 A SUPPLEMENTAL GUIDE TO CODE REVISIONS IMPACTING LIGHTING Hubbell Lighting s Commitment to the ASHRAE 90.1 Challenge Hubbell Lighting understands the challenge

More information

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDSPIR-HB-AD High bay PIR presence detector 1-10V dimming Overview The EBDSPIR-HB-AD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

Education Title Solutions

Education Title Solutions Education Solutions Design Guide Crestron Electronics, Inc. Contents About 1 Design Guide Information 1 Code Standards 2 Classroom 4 Zūm... 4 GLPP... 5 Higher Education Classroom 6 Zūm... 6 GLPAC... 7

More information