compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008
|
|
- Easter Wilkerson
- 5 years ago
- Views:
Transcription
1 iso 9001:2008 Quality Management Systems Systéme de Qualité possibility of additional functions detection of critical temperature detection of flooding electrochemical sensor catalytic sensor infrared sensor semicoductor sensor Detection of more than 200 flammable and toxic gases DEGA 05L-2-AC-x-yL compact detector Products in accordance with Regulation n.361/2007 Coll. Regulation n.312/2005 Coll. n.268/2011 Decree no., and standards: CSN EN (2011) and CSN (2009)
2 Compact detector A digital compact gas detector with a built-in sensor selected in accordance with the type of gas, including evaluation, with an LCD display showing the values measured, with an acoustic alarm and a reset button for the acoustic alarm on the control panel, provided with the function of monitoring the calibration dates and with auto-control, with the option for connecting an additional transmitter, an internal temperature sensor, an external flood sensor and a circuit for controlling the valve using a current pulse. Recommended accessories: DEGA NBx-yl II - external additional transmitter DEGA Zc II - external flood sensor DEGA05L-Tc - internal critical temperature sensor DEGA05L-V - a circuit for controlling emergency valves DEGA05L-12VDC - Special circuit for 12V DC DEGA05L-24VDC - Special circuit for 24V DC The transmitter is not intended for detection and sensing in industrial or commercial premises that require the ATEX certification nor for Ex environments. For these areas, we recommend transmitters of the DEGA NSx-yL types. The DEGA 05L-2-AC-x-yL detector is available with the following sensors: (whereby x= the symbol for a specific gas, y= the symbol for the type of sensor) DEGA05-2-AC-x-EL with an electrochemical sensor This operates on the principle of measurement of the change in the electrical parameters of electrodes placed in electrolyte, due to the redox reaction of detected gas on their surface. These sensors have a favourable selectivity and the capacity to detect very low concentrations of gases. In the DEGA systems they are utilised primarily for the detection of toxic gases. DEGA05-2-AC-x-CL with a catalytic sensor (Pelistor) These work on the principle of catalytic combustion the gas concentration is measured in accordance with the amount of heat released during a controlled combustion reaction. The reaction is prompted by a suitable temperature and the presence of a catalyst. These sensors can be used for the detection of a wide range of combustible gases. The sensors are characterised by their fast response, long life and high degree of stability. For their proper functioning they require at least 10% of the oxygen in the air. In an environment containing corrosive substances (alkaline and/or acidic compounds, silicon, sulphur, lead, etc.) the degradation of the sensor is accelerated. DEGA05-2-AC-x-IL with an infrared sensor (IR) The highest-quality detecting method, which works on the principle of infrared spectroscopy. These sensors excel in the high level of their selectivity and their resistance in environments containing corrosive substances and, under ideal conditions, their theoretically unlimited operating life. DEGA05-2-AC-x-SL with a semiconductor sensor The least expensive method of sensing. They work on the principle of the measurement of the change in the electrical conductivity of semiconductors that occurs in the event of a change in the concentration of the gas detected. Its advantages are its long operating life when it is used in a clean environment and also the wide range of models available for different types of gases and vapours. Its disadvantages are its low degree of selectivity (a lesser ability to distinguish between the different types of gases in the mixture) and in environments containing corrosive substances (alkaline and acidic compounds, silicones, sulphur compounds, etc.) an accelerated degradation of the sensor takes place. Basic types Identification system of the transmitter: Gas transmitter DEGA05L-2-AC-x yl The product type (DEGA 05L) 2-level detection Power supply 230 V AC The type of gas detected A type of sensor with a linear output 2
3 DEGA05L-2-AC-x-CL (catalytic sensor) The type of sensor Detected gas Measuring range Standard alarm setting on the controller DEGA05-2-AC-M-CL DEGA05-2-AC-P-CL Methane (CH4) / Natural Gas (CH4) / CNG (CH4) / Biogas (CH4) Butane (C4H10) / LPG (C4H10) / Propane-butane (C4H10) 0 100% LEL level 1: 10% LEL, level 2: 20% LEL 0 100% LEL level 1: 10% LEL, level 2: 20% LEL DEGA05-2-AC-H-CL Hydrogen (H2) 0-100% LEL level 1: 10% LEL, level 2: 20% LEL DEGA05-2-AC-A-CL Amonia (NH3) 0-100% LEL level 1: 10% LEL, level 2: 20% LEL DEGA05-2-AC-B-CL Gasoline 0-100% LEL level 1: 10% LEL, level 2: 20% LEL DEGA05-2-AC-L-CL Other flammable and explosive gases and vapours, in accordance with the selectivity of the sensor 0-100% LEL level 1: 10% LEL, level 2: 20% LEL Note: LEL - Lower Explosion Limit Alarm settings on the controller can be freely selected (within the measuring range) in accordance with the customer s requirements DEGA05L-2-AC-x-CL (semiconductor sensor) The type of sensor Detected gas Measuring range Standard alarm setting on the controller DEGA05-2-AC-C-SL Carbon monoxide (CO) ppm level 1: 80 ppm, level 2: 130 ppm DEGA05-2-AC-M-SL DEGA05-2-AC-P-SL Methane (CH4) / Natural Gas (CH4) / CNG (CH4) / Biogas (CH4) Butane (C4H10) / LPG (C4H10) / Propane-butane (C4H10) 0 100% LEL level 1: 10% LEL, level 2: 20% LEL 0 100% LEL level 1: 10% LEL, level 2: 20% LEL DEGA05-2-AC-A-SL Amonia (NH3) ppm (accuracy +/- 50ppm) level 1: 300ppm, level 2: 400 ppm DEGA05-2-AC-B-SL Gasoline 0-100% LEL level 1: 10% LEL, level 2: 20% LEL DEGA05-2-AC-F-SL Freon ppm level 1: 300ppm, level 2: 600ppm DEGA05-2-AC-R-SL Refrigerants: R401A, R404A, R407C, R32, R410A, R12, R ppm In accordance with the type of refrigerant DEGA05-2-AC-HFO-SL Refrigerant: HFO-1234yf; R1234yf; 2,3,3,3-Tetrafluoropropylene ppm level 1: 10 ppm, level 2: 20 ppm DEGA05-2-AC-H-SL Hydrogen (H2) 0-100% LEL level 1: 10% LEL, level 2: 20% LEL DEGA05-2-AC-Y-SL Acetylene (C2H2) 0-100% LEL level 1: 10% LEL, level 2: 20% LEL DEGA05-2-AC-L-SL Other flammable and explosive gases and vapours, in accordance with the selectivity of the sensor 0-100% LEL (0 1% vol.) level 1: 10% LEL, level 2: 20% LEL Note: LEL - Lower Explosion Limit Alarm settings on the controller can be freely selected (within the measuring range) in accordance with the customer s requirements 3
4 DEGA05L-2-AC-x-EL (electrochemical sensor) The type of sensor Detected gas Measuring range Standard alarm setting on the controller DEGA05-2-AC-C-EL Carbon monoxide (CO) ppm ( ppm) level 1: 45 ppm, level 2: 130 ppm, ALARM PEL : in accordance with CSN : 120mi n./30ppm Application: Detection in residential buildings If required the PEL ALARM can also be set: a) in accordance with CSN : 30min/87 ppm Application: Underground Garages b) in accordance with Government Regulation No. 321/2007: 8 hours/26 ppm Application: The working environment of employees DEGA05-2-AC-A-EL Amonia (NH3) 0-50ppm (0-1000ppm) level 1: 18 ppm, level 2: 47 ppm Regulation No. 321/2007: 8hod./ 20 ppm DEGA05-2-AC-CL-EL Chlorine (Cl2) 0-20 ppm DEGA05-2-AC-O-EL Oxygen (O2) 0-25% vol. level 1: 1 ppm, level 2: 3 ppm Regulation No. 321/2007: 8hod./0,2 ppm NPK-P: 0,516 ppm level 1: 18% vol., level 2:15% vol. If required the PEL ALARM can also be set: 1 st. 23% vol., level 2:25% vol. DEGA05-2-AC-O3-EL Ozone (O3) 0-5 ppm (0-100 ppm) level 1: 0,1 ppm, level 2: 0,3 ppm Regulation No. 321/2007: 8hod./0,05 ppm NPK-P: ppm DEGA05-2-AC-HCL-EL Hydrogen chloride (HCl) 0-20 ppm level 1: 7 ppm, level 2: 9,3 ppm Regulation No. 321/2007: 8hod./5,43 ppm DEGA05-2-AC-H2S-EL Hydrogen sulfide (H2S) 0-50 ppm (0-200ppm) (0-2000ppm) level 1: 10 ppm, level 2: 13 ppm Regulation No. 321/2007: 8hod./7,1 ppm DEGA05-2-AC-NO2-EL Nitrogen dioxide (NO2) 0-20 ppm ( ppm) level 1: 8 ppm, level 2: 10 ppm Regulation No. 321/2007: 8hod./4,94 ppm DEGA05-2-AC-NO-EL Nitric oxide (NO) ppm ( ppm) level 1: 7 ppm, level 2: 10 ppm Regulation No. 321/2007:8hod./7,57 ppm DEGA05-2-AC-SO2-EL Sulfur dioxide (SO2) 0-20 ppm level 1: 2,5 ppm, level 2: 3,5 ppm Regulation No. 321/2007: 8hod./1,91 ppm DEGA05-2-AC-CH2O-EL DEGA05-2-AC-C2H4-EL DEGA05-2-AC-C2H4O-EL DEGA05-2-AC-H-EL DEGA05-2-AC-HCN-EL DEGA05-2-AC-PH3-EL Formaldehyde (CH2O) Ethene (Ethylene) (C2H4) Ethylenoxide (oxirane) (C2H4O) Acetaldehyd, Vinyl alcohol (ethenol) Hydrogen (H2) Hydrogen cyanide (HCN) Fosfan/Fosfin (PH3) 0-10 ppm ( ppm) 0-10 ppm ( ppm) level 1: 0,3 ppm, level 2: 0,7 ppm level 1: 7 ppm, level 2: 10 ppm 0 10 ppm level 1: 0,8 ppm, level 2: 1,5 ppm ppm (0-4000ppm) 0-50ppm (0-100ppm) 0-5 ppm (0-20 ppm) level 1: 200 ppm, level 2: 400 ppm level 1: 5 ppm, level 2: 8,3 ppm 1. st. 0,1 ppm, 2. st. 0,2 ppm 4
5 The type of sensor Detected gas Measuring range Standard alarm setting on the controller DEGA05-2-AC-SIH4-EL Silane (SiH4) 0-50 ppm level 1: 3 ppm, level 2: 5 ppm DEGA05-2-AC-CLO2-EL Chlorine dioxide (ClO2) 0-1 ppm (0-50ppm) level 1: 0,1 ppm, level 2: 0,2 ppm DEGA05-2-AC-BR2-EL Bromine (Br2) 0-20ppm level 1: 0,1 ppm, level 2: 0,2 ppm DEGA05-2-AC-HBR-EL Hydrobromic acid (HBr) 0-20ppm level 1: 8 ppm, level 2: 9,3 ppm DEGA05-2-AC-L-EL Other chemical substances, in accordance with the customer s requirements In accordance with the type of sensor In accordance with the chemical substance Note: LEL - Lower Explosion Limit Alarm settings on the controller can be freely selected (within the measuring range) in accordance with the customer s requirements DEGA05L-2-AC-x-IL (infrared sensor) The type of sensor Detected gas Measuring range Standard alarm setting on the controller DEGA05-2-AC-CO2-IL DEGA05-2-AC-M-IL DEGA05-2-AC-PB-IL DEGA05-2-AC-PP-IL DEGA05-2-AC-B-IL Carbon Dioxide (CO2) /Biogas (CO2) Methane (CH4) / Natural Gas (CH4) / CNG (CH4) / Biogas (CH4) Butane (C4H10) / LPG (C4H10) / Propane-butane (C4H10) Propane (C3H8) Gasoline 0-5 % vol. (0-100 % vol.) 0 100% LEL 0 100% LEL 0 100% LEL 0-100% LEL level 1: 1,0%, level 2: 2,5% DEGA05-2-AC-N2O-IL Nitrous oxide (N2O) 0 1% vol. level 1: 0,5% vol., level 2:1% vol. DEGA05-2-AC-L-IL Other flammable and explosive gases and vapours, in accordance with the selectivity of the sensor 0-100% LEL Note: PEL ALARM: Permissible Exposure Limit (PEL) of the chemical substance, i.e. the maximum permissible value of the time-weighted average (TWA) of the concentration of the gas in air LEL - Lower Explosion Limit 5
6 Supply Voltage DEGA05L: Cable for the power supply of DEGA05: Cable for the connection Flood sensor DEGA Zc II Cable for the connection additional transmitter DEGA NBx-yL II: Note: In case of connecting sensors with detector DEGA05L at greater distances, please contact the manufacturer. Input: Output: Relay contact ampacity: Technical data and information Ingress protection: IP 43 Working environment: Degree of accuracy: 2,5 Response time (T90): DEGA05-2-AC-x-EL DEGA05-2-AC-x-CL DEGA05-2-AC-x-IL DEGA05-2-AC-x-SL Warm-up time: DEGA05-2-AC-x-EL DEGA05-2-AC-x-CL DEGA05-2-AC-x-IL DEGA05-2-AC-x-SL Stabilisation period: DEGA05-2-AC-x-EL DEGA05-2-AC-x-CL DEGA05-2-AC-x-IL DEGA05-2-AC-x-SL Dimensions (W x H x D): Weight: Type os sensor Expected operational life of the sensor in a clean environment 230 V AC/50Hz cable 3 x 1,5 mm2 cable 4 x 1 mm2 (max.100m) or UTP cat. 5e shielded cable 3 x 1 mm2 (max. 600 m) shielded cable 3 x 1,5 mm2 (max m) 7W 5x relay- a potential-free switching contact resistance load: 8 A / 250 V/50Hz 8 A / 30 VDC inductive load: 1,6 A / 30 VDC BE1 on-explosive atmosphere BNV (CSN EN ) max. 180 seconds (in accordance with the type of sensor) max. 20 seconds max. 15 seconds max. 30 seconds max. 1 min. max. 3 min. 10 sekund max. 3 min. Operating temperature range: -20 to + 60 C Relative humidity of the ambient air: max. 1 hod. (5 dnů bez napájení) max. 6 hod. (5 dnů bez napájení) max. 5 minut (5 dnů bez napájení) max. 6 hod. (5 dnů bez napájení) 225 x125 x57 mm 0,6 kg catalytic, electrochemical, infrared, semiconductor catalytic (3-6 years) electrochemical (1-3 years) infrared (at least 5 years or more) semiconductor (3-6 years) max. 95% with air pressure kpa. 6
7 Accessories DEGA Zc II External flood sensor DEGA NBx-yL II adittional gas transmitter 7
8 Manufacturer: DEGA CZ s.r.o., K Žižkovu 640/9, Prague 9, Czech Republic TAX ID: CZ ; Company ID: ; Phone (cz): , Fax: info@dega.cz, Website: DEGA CZ S.R.O.
3M Oldham OLCT 100. Description. Fixed Gas Detector
Fixed Gas Detector Description The OLC/OLCT range of fixed detectors has been designed for detection of combustible gases, toxic gases or oxygen. Available in explosion-proof or intrinsically safe versions,
More informationOLC(T) 100 FIXED GAS DETECTOR
Fixed Gas Detector OLC(T) FIXED GAS DETECTOR Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version CERTIFICATIONS The
More informationGAS DETECTOR ST400EC PART.NO
DATA SHEET 1(7) GAS DETECTOR ST400EC PART.NO. 004461-004467 DETECTION OF TOXIC GASES AND OXYGEN SYSTEM GS5000, GS3000, SW2020, BUCONTROL / BUTOUCH GENERAL DESCRIPTION Detection of toxic gases and Oxygen
More informationOLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases
DETECTION DE GAZ FIXE OLCT Detection of Combustible, Toxic or Oxygen gases Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Certifications Better detection. Better
More informationDetection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People
Fixed Gas Detector Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Certifications The Fixed Gas Detection People The OLC/OLCT CT range of fixed ddetectors
More informationDetection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version
Fixed Gas Detector Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Certifications Pending The Fixed Gas Detection
More informationDigital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6
Digital Gas Transmitters with Auxiliary s & Control Specifications subject to change without notice. USA 181011 Page 1 of 5 DESCRIPTION Digital RS-485 communicating, addressable toxic and combustible gas
More information3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.
Fixed Gas Monitoring Solutions Detection of explosive gases, toxic gases and oxygen Infrared XP IR version SIL 2 high reliability IP 66 E n o r t c e l i c 3years W a r r a t n y Certifications: The Fixed
More informationREMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS
REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS FEATURES Extremely wide range of sensors Easy installation and maintenance Low cost of ownership Replacement of sensors are simple Rugged and reliable
More informationREMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY
REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY FEATURES TXGARD & FLAMGARD PLUS Digital display with flexible output options Wide range of long life sensors Non-intrusive one-man
More informationSieger Apex. Flexibility that meets your requirements
Sieger Apex Flexibility that meets your requirements Sieger Apex Easy to Install Sensor can be remotely mounted up to 100m from the transmitter On board relays allow for local audible/ visual alarms Strong
More informationXgard. Fixed detectors For flammable, toxic or oxygen gases
Fixed detectors For flammable, toxic or oxygen gases Xgard Xgard Type 1: Xgard Type 2: Xgard Type 3: Xgard Type 4: Xgard Type 5: Xgard Type 6: Xsafe: Intrinsically safe toxic and oxygen gas detector Flameproof
More informationQuality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.
Water Quality Labo- Soil/ Soil/ Sedi- Sam- & Air / Dust Toxic gases are present in a wide variety of industrial and civil installations and their detection and monitoring is crucial for the safe working
More informationALTAIR 5X Multigas Detector Product Specification
ALTAIR 5X Multigas Detector Product Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Weight Handling Case material Environmental protection Display
More informationDEGA NBx-yL III INSTRUCTION MANUAL. Gas Detection Transmitter
INSTRUCTION MANUAL Gas Detection Transmitter DEGA NBx-yL III Reproduction of this manual, or any part thereof, in any form, without the prior permission of DEGA.CZ s.r.o. is prohibited DEGA CZ s.r.o. reserves
More informationP R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification
P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.
More informationMonitores Personales. Personal Monitor
Monitores Personales Personal Monitor Micro IV Full Featured Personal Monitor Micro IV Single-gas Detector Highly configurable smart sensor design Wide range of sensors including O 2, H 2 S, CO, NH 3,
More informationElectrochemical DrägerSensor Sensors for Fixed Gas Detectors
Electrochemical DrägerSensor Sensors for Fixed Gas Detectors Fast response, high accuracy, great stability, long life. Electrochemical DrägerSensors offer all these benefits. You can use the robust and
More information5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots
5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots GX-6000 5 Operating modes Normal Leak Check Inert Bar hole Snap Log Monitor up to
More information5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots
5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots CONFINED SPACE ENTRY Monitor LEL, O2, CO, and H2S Internal sample pump Pull samples
More informationCH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2
PluraSens CH 4 C 2 H 2 C 3 H 8 CO CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2 VOC E2600 Family Gas Detectors E2610 Series Compact wall-mount housing providing optimal airflow Integrated sensor with long
More informationMICRO III (G202 / G202s / G212) Single Gas Detector
Operation Manual MICRO III (G202 / G202s / G212) Single Gas Detector GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 D-44143 DORTMUND TELEPHONE +49 / (0) 2 31 / 5 64 00 0 FAX +49 / (0) 2 31 / 51 63
More informationULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]
ULTIMA XL/XT Series Gas Monitors [ Ultimate Features Extreme Design ] Cost effective fixed installation gas monitors with HART Field Communications Protocol. Single-sensor units use catalytic, electrochemical
More informationSIL 2. Ultima X Series Gas Monitors CERTIFIED
Ultima X Series Gas Monitors 5 Now with SIL 2 CERTIFIED Products Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection
More informationModel D12. Digital Gas Transmitter
Model D12 Digital Gas Transmitter Gas detection systems come in all shapes and sizes. Some require simple 4-20 ma transmission. Some are better suited to local alarm relay functions. Some really require
More informationVASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.
Sheet No. 1 of 4 monitor/analyzer with alarm and Graphical Display. Sheet No. 2 of 4 It specially designed to analyze any gas of your choice, its automatic operation, accurate measurement and crystal clear
More informationMicro III (Models G203, G203S, and G213) Operation Manual
Micro III (Models G03, G03S, and G13) Operation Manual Worldwide Manufacturer of Gas Detection Solutions Table of contents Page Introduction... 3 For your safety... 3 Application and use... 3 General
More information5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors
Ultima X Series Gas Monitors Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection methods. HART Protocol is now
More informationSieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required
Sieger Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sieger Sensepoint Fit For Purpose
More informationEAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility
EAGLE 2 Inlet fitting Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility Internal / external hydrophobic filters Self healing polyurethane protective
More informationESD500. ESD500 Combustible / Toxic Gas Detector
ESD500 ESD500 Combustible / Toxic Gas Detector Combustible and toxic gas leakage inspection instrument in industrial application Ex-proof certificate Exd ⅡC T6 Gb/Ex d ib ⅡC T6 Gb Dust Ex-proof certificate
More informationSatellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases
Satellite XT Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases Satellite XT Applications: Provides gas detection for: Gas cabinets Valve manifold
More informationToxic Gas Detection. Model F12. Toxic Gas Detection
Toxic Gas Detection Model F12 Toxic Gas Detection Smart Sensor Technology The Series F12 Gas Transmitter is an Intrinsically Safe (IS) version of our explosion-proof D12 transmitter. In its standard form,
More informationSatellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases
Satellite XT Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases Satellite XT Applications: Provides gas detection for: Gas cabinets Valve manifold
More informationMurco Core Product Guide Gas Leak Detection Solutions for all your building needs
Murco Core Product Guide Gas Leak Detection Solutions for all your building needs Refrigerant Gases Toxic Gases Combustible Gases VOC s Legislation: F Gas Regulation, EH40 Standards: EN378 Lloyds Approval
More informationESD3000 ESD200 Combustible / Toxic Gas Detector
ESD3000 ESD200 Combustible / Toxic Gas Detector Combustible and toxic gas leakage inspection instrument in industrial application Ex-proof certificate Exd ⅡC T6 Gb/Ex d ib ⅡC T6 Gb Dust Ex-proof certificate
More informationEC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)
Operation Manual EC24 (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414) GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 D-44143 DORTMUND TELEPHONE +49/(0)231 / 564 00 0 FAX +49/(0)231 / 516313 INFO@GFG-MBH.COM
More informationSieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required
Sieger Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sieger Sensepoint Fit For Purpose
More informationSensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications
Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sensepoint Fit For Purpose Flammable,
More informationSelf-contained and intrinsically safe wireless stand-alone multi-point gas detector.
Introduction United Safety applies the detection system as a multi-point monitoring for toxic gases, combustibles and oxygen hazards. Self-powered and solar-capable, the features unequaled versatility,
More informationSP-220. Features. Combustible handheld gas leakage detector
SP-220 Combustible handheld gas leakage detector The SP-220 gas leakage detector is a simple to operate unit with high sensitivity to a variety of gases. The SC version (SP-220SC) is able to detect super-toxic,
More informationMultiRAE Lite. Wireless Portable Multi-Gas Monitor
MultiRAE Lite Wireless Portable Multi-Gas Monitor The MultiRAE Lite is an optimal one-to-six 4 -gas monitoring solution for personal protection (including confined space entry) and multi-gas leak detection
More informationProduct Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety
Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety GDS Corp gas monitors, controllers and sensors satisfy today s needs for safety and reliability in critical gas detection
More informationFrequently Asked Questions
1. 2. What advantages does the GT3000 have over the C7064? Hot swappable GTS sensor module is intrinsically safe and allows live maintenance under power Supports HART communication Supports local, one-person
More informationFREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS
FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS FREEDOM SERIES 5000 & 5600 MAKING INSTALLATION AND EVERYDAY OPERATION EASY The Freedom Series 5000 and 5600 are full-featured 4-20mA, loop powered transmitters
More informationGas Detection. - Disposable - Serviceable. Single Gas Detectors
Gas Detection Single Gas Detectors Introduction Portable single gas detectors are used for personal protection and have the ability to detect a single gas hazard. Typically they are small, lightweight
More informationSPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System
SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM User Instructions For The Model 5200 Gas Monitor System To completely customize the specifications to your exact application, modifications to the following
More informationStand Alone DYNAGARD SP Operation Manual
Stand Alone DYNAGARD SP Operation Manual Contents Page General Description 1 Detection Principle 1 For Your Safety 1 Design 2 Mounting 2 Mounting Position of DYNAGARD SP 2 Installation of Electrical Connections
More informationTransmitters/Sensors. OLCT Series
Transmitters/Sensors Gas Monitoring Solutions OLCT 20-40-50-60 Series SIL2 based on EN 50402 (OLCT 60 based on EN 50271) FLP approved Intrinsically Safe (IS) Precalibrated block module local or remote
More informationWARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro
A d e v i h c r D c o n e m u WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship
More informationFixed Gas & Flame Detection International Product Range Overview
Fixed Gas & Flame Detection International Product Range Overview Over 100 years of experience and capability in comprehensive safety solutions have made MSA a modern and forward-looking company for the
More informationAPPLICATION DATA SHEET
APPLICATION DATA SHEET S p e c i f i c a t i o n WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700 D e t e c t o r C o n t r o l P a n e l Wall mounting 24V DC or 110/230vAC operation
More informationDetectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.
Détecteur de gaz OLCT80 Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Disponible en version déportée, ADF ou de SI
More informationSensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications
Sensepoint The Sensepoint range of flammable, toxic and Oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sensepoint Fit For Purpose Flammable,
More informationLeak detector for refrigerant gases R22, R134a, R410A, R407C...
PCE-GA3 PCE-LD 1 PCE-GA 70 Pen-sized flammable gas detector Leak detector for refrigerant gases R22, R134a, R410A, R407C... CO2 detector with data logger and software This pen-sized flammable gas detector
More informationPolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen
PolyGard Single Point Controller SPC-X3-XX for Toxic Gases and Oxygen DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor and
More informationALTAIR 5X Multigas Detector
ALTAIR 5X Multigas Detector With MSA XCell Sensor Technology IT S WHAT S INSIDE THAT COUNTS Now with advanced PID for VOC Detection Because every life has a purpose IT S WHAT S INSIDE THAT COUNTS WORKERS
More informationMiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING
MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2 TM, and MiniClO 2 TM Responder Detectors Instruction Manual "! WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE
More informationGasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability
GasSens Modular Gas Detector... Self Checking Gas Sensors GasSens is a flexible component system providing a variety of options to meet individual gas detection and alarm requirements. From chemical and
More informationKAE Gas Alarm Operation Manual
KAE Gas Alarm Operation Manual Henan Hanwei Electronics Co.,Ltd ISO9001-2008 Precautions: To avoid personal safety injury, Instrument damage and potential dangerous accident; do not use gas detector before
More informationMICRO IV. Operation Manual. Single Gas Detector
Operation Manual MICRO IV Single Gas Detector GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 D-44143 DORTMUND TELEPHONE +49 / (0) 2 31 / 5 64 00 0 FAX +49 / (0) 2 31 / 51 63 13 INFO@GFG-MBH.COM WWW.GASDETECTION.BIZ
More informationWarranty Registration
WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship and materials for a period
More informationDräger X-am 7000 Multi-Gas Detection
Dräger X-am 7000 Multi-Gas Detection Dräger X-am 7000 is the solution for the simultaneous and continuous measurement of up to five gases. It is the ideal companion in a variety of applications where the
More informationSingle Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3
Single Gas Detector H 2 S CO O 2 SO 2 NH 3 PH 3 Cl 2 ClO 2 NO NO 2 HCN ETO O 3 Long-term solution Compact and affordable, the GasAlert Extreme reliably monitors for any single gas hazard within its wide
More informationMany different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex
Part 2 Direct Reading Instrumentation Direct Reading Instruments Many different instruments Many different operating principles including: Electrochemical Photoionisation Flame ionisation Chemiluminescence
More informationTOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts
TOCSIN 750 SERIES SAFE AREA S -Wire Addressable Systems Addressable Interface to Controller. Network up to 3 Annunciators or other Addressable Devices per Highway. -Wire Addressable Core Cable Unscreened
More informationMSA Portable Gas Detection
Because every life has a purpose MSA Portable Gas Detection Marine Chemist Association Seminar 2015 Paul Jung Product Line Manager Portable Instruments Our Mission & Vision Mission to see to it that men
More informationtesto 316-EX gas leak detector Instruction manual
testo 316-EX gas leak detector Instruction manual 2 1 Safety and the environment 1 Safety and the environment 1.1. About this document Use > Please read this documentation through carefully and familiarize
More informationDräger X-am 5600 Personal Monitor Multi-Gas Detection Device
Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device Featuring an ergonomic design and innovative infrared sensor technology, the Dräger X-am 5600 is the smallest gas detection instrument for the
More informationincontrol Systems Inc. Flame and Gas Detection
incontrol Systems Inc. Flame and Gas Detection Our flame and gas detectors are globally certified to the latest product approval standards Wherever toxic or combustible gases are part of an industrial
More informationGMA 36 Pro. Operation Manual. Stand Alone Monitor
Operation Manual GMA 36 Pro Stand Alone Monitor GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 D-44143 DORTMUND TELEPHONE +49 / (0) 2 31 / 5 64 00 0 FAX +49 / (0) 2 31 / 51 63 13 INFO@GFG-MBHCOM WWWGASDETECTIONBIZ
More informationExplosion protection Marijan Gorše, dipl. ing.
Explosion protection Marijan Gorše, dipl. ing. 1/18 Flammable Gas Atmosphere We Can Control Them Explosion hazards mostly arise from flammable gases and vapours. Instead of avoiding their ignition by explosion
More informationMicrotector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions
Microtector II G460 7-gas-detector with performance test approval Performance test approved multi-gas detector (290g) Extremely loud alarm, 103 db(a) for optimum personnel protection Full featured, rugged
More informationTwo-Channel Gas Controller
Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously
More informationConfined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012
Confined Space Monitoring Leak Investigation 1 Functions 4 Bar Hole Sampling Line Purge Testing Actual Size GX-2012 3 Operating Modes Internal sample draw pump with 50 range Low flow alarm 3 bright visual
More informationMicro IV Operation Manual
Micro IV Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS Page Introduction...4 For Your Safety...4 Application and Use...4 General Description...4 Detection Principle...5
More informationGas Detection For Life
FIXED SYSTEMS Controllers Explosion Proof Transmitters Harsh Environment Systems Digester Gas Monitor PORTABLE SOLUTIONS Smallest Confined Space Personal 6 Gas with PID, IR and Toxic Single Gas Personal,
More information4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head
4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.
More informationThe Art of Gas Detection
The Art of Gas Detection Flammable & Toxic Gas Detectors Smart Alarm Controllers Fire & Gas System Engineering Technical Service & Support 1 R.C. Systems has manufactured electronic and gas detection products
More informationULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]
ULTIMA XIR ULTIMA X 3 ULTIMA XE ULTIMA X Series [ State-of-the-Art Gas Monitoring] ULTIMA X Gas Monitors [ Providing a unique Range of Capabilities] ULTIMA X are state-of-the-art gas monitors for continuous
More informationALTAIR 5X Multigas Detector
ALTAIR 5X Multigas Detector With MSA XCell Sensor Technology IT S WHAT S INSIDE THAT COUNTS Now with advanced PID for VOC detection Because every life has a purpose... Save Time, Save Money, Save Lives
More informationportable gas analyser
www..com portable gas analyser The largest of s analysers equipped with electrochemical cells. It can fit even up to 7 EC cells and up to 3 sensors. GA-60 has a large (320*240), graphical LCD with backlighting.
More informationGS100M Gas Detection Controller
GS100M Gas Detection Controller GS100M 1 Zone Gas Detection Controller 1 Zone / Sensor Conventional Positive Safety IP44 EN61010-1 EN50270 FEATURES Single Zone Protection Positive Safety Option Detection
More informationCarbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output
Features Electrochemical sensor element (0)2-10 Vdc or (0)4-20 ma output, jumper selectable Standard IP65 plastic enclosure Measuring ranges 0-50 ppm 0-100 ppm 0-150 ppm 0-200 ppm 0-250 ppm 0-300 ppm 0-500
More informationGMA 36 Pro. Operation Manual. Stand Alone Monitor
Operation Manual GMA 36 Pro Stand Alone Monitor GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 D-44143 DORTMUND TELEPHONE +49 / (0) 2 31 / 5 64 00 0 FAX +49 / (0) 2 31 / 51 63 13 INFO@GFG-MBH.COM
More informationSafe Operation Manual. Honeywell IQ Force Gas Detector
Safe Operation Manual Honeywell IQ Force Gas Detector Honeywell Analytics 800-663-4164 403-248-9226 Fax 403-575-3708 03JUN2012 P/N 50105843-047 Version 01 http://www.honeywell.com HONEYWELL IQ Force PERSONAL
More informationModel D12-IR. Digital Gas Transmitter...
Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact
More information1.1 Definitions of alert icons. For your safety
For your safety 1 For your safety Before using this product, carefully read these Instructions for Use and those of the associated products. Strictly follow the Instructions for Use. The user must fully
More informationMSA XCell Sensors. Because every life has a purpose
MSA XCell Sensors Because every life has a purpose XCell Sensors MSA XCell Sensors are a breakthrough in sensor design, enabling faster response and shorter span calibrations, saving you time and money.
More informationIntelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.
Features To measure and take control of indoor air quality Three noses in same unit Air Quality (VOC), Humidity (rh) and Temperature (T) Selectable outputs 0-10 Vdc, 4-20 ma or 0-5 Vdc via jumpers on pcb
More informationOLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1
User Manual OLCT 10N Digital Gas Detector Part Number: NPO10NEN Version: G.1 The Fixed Gas Detection Experts Copyright 2015 by OLDHAM S.A.S May 2015 All rights reserved. No reproduction of all or part
More informationSensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.
Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs. Sensepoint One-Stop Shop Flammable, toxic and oxygen versions
More informationIGD.CO.UK
APPLICATION DATA SHEET S p e c i f i c a t i o n 2 SO22 WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700+ D e t e c t o r Website: C o n t r o l P a n e l - Wall mounting or 19 Rack
More informationia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]
II 2G EEx ia d ATEX 100 D MT IIC T6 99 ATEX G 001 x Series [ Versatility in Explosive Atmospheres] [ The flexible solution for all your needs] After accidents with hazardous material the will provide reliable
More informationEXAMPLES OF HOW TO ORDER
E 3 Point PRODUCT SUBMITTAL Toxic and Combustible Gas Detector Standalone Platform (Single or Dual-Gas Monitoring) ORDERING INFORMATION Single-Gas or Dual-Gas Configuration: Base Unit, Surface-Mount Base
More informationEXAMPLES OF HOW TO ORDER
E 3 Point PRODUCT SUBMITTAL Toxic and Combustible Gas Detector Standalone Platform (Single or Dual-Gas Monitoring) ORDERING INFORMATION Single-Gas or Dual-Gas Configuration: Base Unit, Surface-Mount Base
More informationIndustrial Grade Gas Detection Detecting The Difference
detcon inc. Industrial Grade Gas Detection Detecting The Difference PO Box 8067 The Woodlands, TX 77387 888-367-4286 (toll free) 713-559-9200 281-292-2860 (fax) sales@detcon.com Catalog #CB-0409 www.detcon.com
More informationDETCON MODEL SERIES 700 GAS DETECTORS
DETCON MODEL SERIES 700 GAS DETECTORS DETCON MODEL SERIES 700 GAS DETECTORS Model Series 700 Gas Detectors Description Detcon Model Series 700 industrial gas detection sensors are a new generation of intelligent
More informationModel Series 700. detcon. Environmentally Bulletproof Gas Detection Sensors. Multi-Layer Surge Protection Water-Proof Corrosion-Proof
PO Box 8067 The Woodlands, TX 77387 888-367-4286 (toll free) 281-367-4100 281-292-2860 (fax) sales@detcon.com detcon Model Series 700 Environmentally Bulletproof Gas Detection Sensors Multi-Layer Surge
More informationMICROpeL 75 Combustible Gas Sensor Part Number: PM
MICROpeL 75 Combustible Gas Sensor Part Number: PM759-000 Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance Reduced
More information