"Options" Sensor Module

Size: px
Start display at page:

Download ""Options" Sensor Module"

Transcription

1 "Options" Sensor Module E-790B INSTALLER GUIDE V1.1-2/07 IQ-SNL-MOD-180 IQ Europe Limited Sandbeck Lane, Wetherby LS22 7TW. Visit us at Installation helpline

2 MANUFACTURER'S EXTENDED WARRANTY In addition to your statutory rights relating to this product it is also guaranteed by IQ (Europe) Limited ("IQ") for 12 months from the date of purchase against faulty materials or workmanship which affect its designed ability to detect or switch. During this period if the product has a defect of this nature it will be repaired or replaced free of charge by IQ with the same item, or a similar one of higher specification, ON CONDITION THAT:- The buyer takes advantage of any 'return to store' scheme operated by the seller from whom it is bought. If the product has a defect outside the period of any seller's 'return to store' scheme it should be returned to IQ (Europe) Limited at Sandbeck Lane, Wetherby, W. Yorks LS22 7TW, England at the expense of the buyer together with evidence of the date of purchase (it is the responsibility of the buyer to prove delivery to IQ). The product has been bought by the user. The product has not been misused or handled carelessly, installed incorrectly, or used on a voltage supply other than that shown on it. Repairs have not been attempted by anyone other than IQ's staff. The product has been used for domestic purposes only. The product has not been installed in any unusually exposed or harsh environmental conditions. If the buyer is resident in the EU the product or its replacement will be returned to the buyer at the expense of IQ. This guarantee excludes liability for discolouration of paint or plastic, or any user replaceable parts and in particular lamps, glass panels, or globes/lanterns. It does not confer any rights other than those expressly set out above and does not cover any claims for consequential loss or damage. This guarantee is offered as an additional benefit and does not affect your statutory rights as a consumer. This contract is subject to the laws of England and Wales. *** IMPORTANT *** As of 1 January 2005, changes to the Building Regulations affect domestic electrical installations in England and Wales. You don't need to be a qualified electrician to make changes to your home's electrical system, but the work must be done in accordance with the Regulations. Where you employ an electrician who is a member of a competent person self-certification scheme, they will be able to certify the work complies with the Regulations. If you decide to carry out the work yourself we recommend that you make yourself aware of the Regulations before you begin and if you require any clarification you should contact your Local Authority Building Control Department. Details of the Building Regulations can be obtained on the internet via the government website gov.uk/explanatory-booklet

3 SECTION ONE GENERAL INFORMATION Thank you for buying the IQ OPTIONS Sensor Module and we hope you will be fully satisfied with your choice. For your own safety you should read this leaflet before using your unit as it offers advice and precautions for installation and use. This OPTIONS Sensor Module has been designed for you to add control to the range of OPTIONS useful and attractive light fittings. Each and every OPTIONS light fitting is manufactured with the capability to accept this OPTIONS Sensor Module. Installation of this Sensor Module converts the light fitting from a manual into an automatic unit with three different control OPTIONS for you to select from. Without the OPTIONS Sensor module fitted you will need to manually turn your light fitting on and off as and when you need it. With the OPTIONS Sensor Module fitted you can forget about having to remember to switch the unit on or off as the sensor module will do this for you. The OPTIONS Sensor Module can be fitted at any time, before during or after the installation of your OPTIONS light fitting. Once the OPTIONS Sensor Module has been installed you can choose from the following OPTION 1. Dusk-Dawn "Night Sensor" Mode; the unit will illuminate at a level of darkness set by you, and will remain illuminated throughout the night, switching itself off at dawn. This mode is ideal for use with low energy lamps but check your OPTIONS Light Fitting to see if it can use Low Energy lamps. OPTION 2. Motion Sensor Mode; the unit will begin to operate at a level of darkness set by you, illuminating only when the sensor detects movement. The unit will then remain illuminated for a period set by you, returning to the off position when activity ceases. This mode is ideal if you just want light when it is needed. OPTION 3. Night & Motion Sensor, "Hi-Lo" Mode; the unit will operate as per the Motion Sensor mode except that at dusk the unit will illuminate to a dimmed level set by you (0-50%), switching to full brightness when motion is detected for between 5 seconds and five minutes, returning to the dimmed level when activity ceases and switching off completely at dawn. This mode is ideal if you want a little bit of light to enhance the night time appearance of your home but with more light being automatically available when movement is detected. DO NOT USE compact fluorescent lamps in HiLo mode as it will damage both the lamp and the OPTIONS module.

4 PARTS INCLUDED - PIR Sensor unit. - Instruction manual. Please keep safe for future reference. TOOLS & PARTS NEEDED - Terminal or Electricians screwdriver. Lamps used in OPTIONS fittings must not exceed maximum 40W tungsten halogen, 100W incandescent or 26W compact fluorescent. PLEASE REFER TO THE INSTRUCTION MANUAL FOR THE OPTIONS LANTERN YOU HAVE PURCHASED FOR FURTHER INFORMATION ON SPECIFIC LAMP TYPE AND MAXIMUM LOAD. IMPORTANT!!! The OPTIONS module can be used to control compact fluorescent lamps in PIR and Dusk/ Dawn mode, however, we recommend that the minimum on time is set to no less than 1 minute in order to allow compact fluorescent lamps to reach maximum brightness Compact fluorescent lamps MUST NOT be used when the module is in HiLo Mode. PLEASE CAREFULLY REFER TO SECTION 4 "OPERATION AND TESTING" TO ENSURE THE LAMP TYPE YOU PREFER IS COMPATIBLE WITH THE OPTION MODE YOU REQUIRE SECTION TWO SELECTING THE LOCATION The motion detector has a number of detection zones, at various vertical and horizontal angles as shown (see diagram A). A moving human body needs to cross/enter one of these zones to activate the sensor. The best all-round coverage is achieved with the OPTIONS lantern mounted at the optimum height of 1.8m. The lantern can be installed higher than 1.8m, the range will increase but sensitivity will reduce. Careful positioning of the sensor will be required to ensure optimum performance. See diagram A detailing detection range and direction. The sensor is more sensitive to movement ACROSS its field of vision than to movement directly TOWARDS (see diagram B). Therefore position the unit so that the sensor looks ACROSS the likely approach path. Avoid positioning the lantern where there are any sources of heat in the detection area (extractor fans, tumble dryer exhausts etc.). Reflective surfaces (ie pools of water or white-painted walls) and overhanging branches may cause false activation under extreme conditions. During extreme weather conditions the motion sensor may exhibit unusual behaviour. This does not indicate a fault with the sensor. Once normal weather conditions return, the sensor will resume normal operation. OPTIONS lanterns are for outdoor use only. Unit must be mounted on a non-flammable surface as a fixed luminaire, and is not suitable for portable use.the unit can get very hot during use. Ensure the unit has cooled before handling.ensure adequate ventilation space is allowed between the unit and any object above, in front or to either side of the unit. Suggested space is 0.5m above, 0.3m to either side & 1.0m in front. Do not attempt to install during wet weather, if you are suffering from nausea or dizzy spells or on medication with similar side effects If in any doubt, consult a qualified tradesperson or electrician.

5 SECTION THREE INSTALLATION *** IMPORTANT *** Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation. If you have bought this OPTIONS sensor module at the same time as your OPTIONS lantern, install the lantern according to its own instruction manual, and fit the module referring to Module Insertion below. Alternatively if you have previously purchased and installed the OPTIONS lantern, you will need to remove the circular blanking plate. Ensure the power to the unit is off. Simply insert your terminal screwdriver into the slots at either side of the blanking plate and prise the cover off and continue to Module Insertion below. Module Insertion. The OPTIONS lantern uses an internal rotating sleeve which holds the corresponding connector to which the module must be connected. The internal sleeve will be protruding from the lantern and the clip will be visible on new units. See diagram C. Grip the square protrusion inside the sleeve within the lantern, carefully turn the internal sleeve clockwise until it is fully extended and exposes the rectangular locating clip shown. See diagram C. Align the arrow with the groove in the sleeve and the rectangular clip will locate onto the module. The module is now connected to the lantern and the adjustment knobs are visible to allow you to set up according to your preferred OPTION. SECTION FOUR OPERATION AND TESTING OPTION 1: DUSK-DAWN MODE IT IS ACCEPTABLE TO USE COMPACT FLUORESCENT (CFL ES), LOW ENERGY LAMPS UP TO 26W MAX IN DUSK-DAWN MODE The unit will illuminate at a level of darkness set by you, and will remain illuminated throughout the night, switching itself off at dawn. This mode is ideal for use with low energy lamps but check your OPTIONS Light Fitting to see if Low Energy lamps are capable of being installed. See Diagram D showing adjustment knob identification.

6 Using your terminal screwdriver, carefully set the adjustment controls as follows:- MODE Turn the MODE control fully clockwise to the DUSK-DAWN setting. DIM The DIM setting is inhibited when the OPTIONS module is in DUSK-DAWN MODE TIME The TIME setting is inhibited when the OPTIONS module is in DUSK-DAWN MODE LUX. The Lux setting determines at which light level the unit will turn ON Turn the LUX control fully clockwise to allow you to test the circuit during daylight. Rotate the module clockwise and the module will rotate upwards and into the lantern, rotate until the module is fully flush with the surface of the lantern. Connect the unit to the mains and switch power on. The unit will immediately illuminate for approximately 30 seconds then go off for a short period, then turn on permanently. This indicates the OPTIONS module is connected correctly. DUSK-DAWN MODE: SETTING UP FOR AUTOMATIC OPERATION The LUX control determines the level of darkness required for the unit to start operating. The setting is best achieved by the procedure below: Set the LUX control knob fully anti-clockwise. Wait until darkness falls. When the ambient light level reaches the level of darkness at which you wish the lamp to become operative (ie. At dusk), SLOWLY rotate the control in a clockwise direction until a point is reached where the lamp illuminates. Leave the control set at this point. At this position, the unit should become operative at approximately the same level of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when it is quite light), adjust the control slightly anti-clockwise. If the unit starts to operate too late (ie. only when it is very dark), adjust the control slightly clockwise. Continue to adjust until the unit operates as desired. MANUAL OVERRIDE MODE The light can be switched on for longer time periods by use of the Manual Override Mode. This can be activated at night by using the internal wall switch or circuit breaker. To activate Manual Override Mode:- Switch the internal wall switch/circuit breaker once (off/on) within 1 second. The unit will now illuminate continuously until dawn or until it is switched back into Auto Mode. To de-activate Manual Override Mode (ie. switch the unit back into Dusk-DawnMode):- Switch the internal wall switch/circuit breaker once (off/on) within one second and the unit will illuminate until dawn then revert to its previous operation. Installation is complete.

7 OPERATION AND TESTING OPTION 2 : PIR MODE IT IS ACCEPTABLE TO USE COMPACT FLUORESCENT (CFL ES), LOW ENERGY LAMPS UP TO 26W MAX IN PIR MODE. However, recommend that the minimum on time is set to not less than 1 minute in order to allow compact fluorescent lamps to reach maximum brightness before switching off. The unit will begin to operate at a level of darkness set by you, illuminating only when the sensor detects movement. The unit will then remain illuminated for a period set by you, returning to the off position when activity ceases. See Diagram showing adjustment knob identification. Using your terminal screwdriver, carefully set the adjustment controls as follows:- MODE Turn the MODE control fully anti-clockwise to the PIR setting. DIM The DIM setting is inhibited when the OPTIONS module is in PIR MODE TIME The TIME setting determines how long the unit is switched on following activation by movement Turn the TIME control fully anti-clockwise to the 5 sec. setting. LUX. The Lux setting determines at which light level the unit will turn ON Turn the LUX control fully clockwise to allow you to test the circuit during daylight. Rotate the module clockwise and the module will rotate upwards and into the lantern, rotate until the module is fully flush with the surface of the lantern. Connect the unit to the mains and switch power on. WALK TEST PROCEDURE The unit will immediately illuminate for approximately 30 seconds then go off for a short period, then turn on for approximately 5 seconds when movement is detected. This indicates the OPTIONS module is connected correctly. The unit is now in Test Mode. TEST MODE The lamp will now illuminate for approximately 5 seconds every time movement is detected. Walk across the detection area approximately 5 metres from the unit. Each time you are detected the lamp will illuminate. Now stand still until the lamp extinguishes (this should take approx. 5 seconds) Start moving again, when you are detected again the lamp will illuminate. Repeat the above, walking at various angles and distances to the unit. This will help you to establish the detection pattern.

8 PIR MODE: SETTING UP FOR AUTOMATIC OPERATION The TIME setting controls how long the unit remains illuminated following activation and after all motion ceases. The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the maximum time (fully clockwise) is approx. 5 minutes. Set the control to the desired setting between these limits. The LUX control determines the level of darkness required for the unit to start operating. The setting is best achieved by the procedure below: Set the DUSK control knob fully anti-clockwise. Wait until darkness falls. When the ambient light level reaches the level of darkness at which you wish the lamp to become operative (ie. At dusk), SLOWLY rotate the control in a clockwise direction until a point is reached where the lamp illuminates. Leave the control set at this point. At this position, the unit should become operative at approximately the same level of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when it is quite light), adjust the control slightly anti-clockwise. If the unit starts to operate too late (ie. only when it is very dark), adjust the control slightly clockwise. Continue to adjust until the unit operates as desired. MANUAL OVERRIDE MODE The light can be switched on for longer time periods by use of the Manual Override Mode. This can be activated at night by using the internal wall switch or circuit breaker. To activate Manual Override Mode:- Switch the internal wall switch/circuit breaker once (off/on) within 1 second. The unit will now illuminate continuously until dawn or until it is switched back into Auto Mode. To de-activate Manual Override Mode (ie. switch the unit back into PIR Mode):- Switch the internal wall switch/circuit breaker once (off/on) within one second and the unit will illuminate until dawn on detection then revert to its previous operation. The OPTIONS module can be rotated 45 degrees left and 45 degrees right when fully inserted to allow you to further control the detection pattern See diagram D For further information see diagram A for detection pattern and range information. Installation is complete.

9 OPERATION AND TESTING OPTION 3 : Hi Lo Mode DO NOT USE COMPACT FLUORESCENT (CFL ES), LOW ENERGY LAMPS IN HI LO MODE. IT WILL DESTROY THE OPTIONS SENSOR The unit will operate as per the PIR MODE mode except that at dusk the unit will illuminate to a dimmed level set by you (0-50%), switching to full brightness when motion is detected for between 5 seconds and five minutes, returning to the dimmed level when activity ceases and switching off completely at dawn. See Diagram D showing adjustment knob identification. Using your terminal screwdriver, carefully set the adjustment controls as follows:- MODE Turn the MODE control so the arrow is pointing to the Hi-Lo setting. DIM The DIM setting allows you to adjust the light level that at dusk the unit will illuminate to a dimmed level set by you (0-50% of optimum light output), Turn the DIM control fully anti-clockwise to the 0% setting. TIME The TIME setting determines how long the lantern is switched on following activation by movement Turn the TIME control fully anti-clockwise to the 5 sec. setting. LUX. The Lux setting determines at which light level the lantern will turn ON Turn the LUX control fully clockwise to allow you to test the circuit during daylight. Rotate the module clockwise and the module will rotate upwards and into the lantern, rotate until the module is fully flush with the surface of the lantern. Connect the unit to the mains and switch power on. WALK TEST PROCEDURE The lantern will immediately illuminate for approximately 30 seconds then go off for a short period, then turn on for approximately 5 seconds when movement is detected. This indicates the OPTIONS module is connected correctly. The unit is now in Test Mode. TEST MODE The lamp will now illuminate for approximately 5 seconds every time movement is detected. Walk across the detection area approximately 5 metres from the unit. Each time you are detected the lamp will illuminate. Now stand still until the lamp extinguishes (this should take approx. 5 seconds) Start moving again, when you are detected again the lamp will illuminate. Repeat the above, walking at various angles and distances to the unit. This will help you to establish the detection pattern. The OPTIONS module can be rotated 45 degrees left and 45 degrees right when fully inserted to allow you to further control the detection pattern. See Diagram A for detection range and angles.

10 HI LO MODE: SETTING UP FOR AUTOMATIC OPERATION The TIME setting controls how long the unit remains illuminated following activation and after all motion ceases. The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the maximum time (fully clockwise) is approx. 5 minutes. Set the control to the desired setting between these limits. The DIM setting control determines the brightness of the lamp in the dimmed mode. Set the control between minimum (fully anti-clockwise, dimmer OFF) and maximum (fully clockwise, 50% output) at the desired level. The LUX control determines the level of darkness required for the unit to start operating. The setting is best achieved by the procedure below: Set the LUX control knob fully anti clockwise. Wait until darkness falls. When the ambient light level reaches the level of darkness at which you wish the lamp to become operative (i.e.: at dusk) SLOWLY rotate the control in a clockwise direction until a point is reached where the lamp illuminates. Leave the control set at this point. At this position the unit should become operative at approximately the same level of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (i.e.: when it is quite light) adjust the control slightly anti-clockwise. If the unit starts to operate too late (i.e.: when it is very dark). Adjust the control slightly clockwise. Continue to adjust until the unit operates as desired. MANUAL OVERRIDE MODE The light can be switched on at full power for longer time periods by use of the Manual Override Mode. This can be activated at night by using the internal wall switch or circuit breaker. To activate Manual Override Mode:- Switch the internal wall switch/circuit breaker once (off/on) within 1 second. The unit will now illuminate continuously at full power until dawn or until it is switched back into Auto Mode. To de-activate Manual Override Mode (ie. switch the unit back into Hi-Lo Mode):- Switch the internal wall switch/circuit breaker once (off/on) within one second. The unit will revert to its previous DIM setting until either activated by movement or switched off at dawn. The OPTIONS module can be rotated 45 degrees left and 45 degrees right when fully inserted to allow you to further control the detection pattern See diagram D For further information see diagram A for detection pattern and range information. Installation is complete. IMPORTANT!! If you decide to change your OPTION module MODE of operation, DO NOT SIMPLY CHANGE THE MODE SETTING BY TURNING THE MODE CONTROL TO ANOTHER SETTING. THIS CAN DAMAGE THE UNIT. The procedure is:- 1. Turn off power 2 Change MODE setting as desired 3. Adjust DIM. LUX and TIME settings as described above in the OPTIONS above 4. Turn on power and follow relevant OPTIONS set up instructions above.

11 SECTION FIVE TECHNICAL SPECIFICATIONS Detection Range/Detection Angle Power Supply Maximum Switchable Load Time On Adjustment Dusk Level Adjustment Dim Level Adjustment Environmental Protection Up to 8m at 140 degrees Up to 2m left/right at 180 degrees (see diagram A) 230V AC ~ 50Hz 40W Tungsten Halogen 100W Incandescent 26W Compact Fluorescent. REFER TO MANUAL 5 seconds - 5 minutes Day & night or night only operation 0-50% of maximum output. IP44 (suitable for outdoor use) NEED SOME HELP? If you experience problems or need some advice, first refer to Troubleshooting Guide. If problems still exist, do not immediately return the unit to store. Visit for online installation assistance, product support, downloads, FAQ's etc. Alternatively you can call the IQ Customer Helpline Weekdays 9.00am pm or us : support@iq-group.com Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query. TECHNICAL DATA Rated current : 0.45A Rated impulse withstand voltage : 2500V Duty-type : Short-time duty Type of switch : Single pole, single load Proof tracking index PTI : 175V Level of glow-wire test : Level 3 Not requiring forced cooling

12 SECTION SIX TROUBLESHOOTING GUIDE PROBLEM Lamp stays ON all the time at night. SOLUTION The unit is in DUSK DAWN MODE, turn the power off and reset in either PIR or Hi-Lo MODE If the unit is already in PIR or Hi-Lo MODE:- The unit may be suffering from false activation. Cover the sensor lens completely with a thick cloth. This will prevent the sensor from "seeing" anything. If the unit now switches off after the set time duration and does not re-activate, this indicates that the problem was caused by false activation. The problem may be solved by slightly adjusting the direction of the sensor head (see section 4, OPTIONS 2 & 3.) OPTIONS PIR keeps activating for no reason / at random. Ensure the unit is not positioned so as to allow detection of cars/people using public thoroughfares adjacent to your property. OPTIONS sensor will not operate at all. Check that the power is switched ON at the circuit breaker/ internal wall switch. Turn OFF the power to the unit and check the wiring connections as per the diagram on the OPTIONS lantern you have purchased. Ensure no connections are loose. Check the lamp. If the lamp has failed, replace. Ensure that the lamp is seated correctly in the lampholder. Check the OPTIONS module is fitted correctly, remove using a screwdriver and replace, ensure that the the module is firmly fitted into the sleeve and that the clip and arrow are in their correct positions. See diagram C. The OPTIONS sensor will not operate at night. Unit activates during the daytime The level of ambient light in the area may be too bright to allow operation at the current LUX setting. During the hours of darkness, adjust the LUX control slowly clockwise until the lamp illuminates. Refer to previous section for more details. Check that the sensor location is not close to other light sources. The level of ambient light in the area may be too dark for the current DUSK setting. During daylight, adjust the DUSK control slightly anti-clockwise. When the lamp load extinguishes, enter the detection area. If the PIR still activates, the setting is still too high. Repeat the above procedure until the PIR does not activate when you enter the detection area. Refer to previous section for more details.

13 PROBLEM OPTIONS PIR coverage is poor/sporadic Detection range varies from day to day SOLUTION Unit may be poorly located. See previous section - Selecting The Location and re-locate the unit. PIR sensors are influenced by climatic conditions. The colder the ambient temperature, the more effective the sensor will be. You may need to make seasonal adjustments to the sensor head position to ensure trouble-free operation all year round. DID YOU KNOW... IQ products are designed and manufactured to give many years of trouble-free service. The materials used during manufacture have been selected to improve their ability to be recycled when the product is no longer functional. Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice SAVE MONEY & HELP THE ENVIRONMENT Consider using smaller wattage lamp. This could save you up to 40% in running costs, whilst also conserving precious natural resources. LIGHT POLLUTION & CONSIDERATE LIGHTING Please be aware of the annoyance over-lighting an area can cause to your immediate neighbours. Light pollution caused by incorrectly installing a lantern or over-lighting an area can be limited by carefully considering the location and position of your lantern before installation. Please try to concentrate the light on your property and limit the potential inconvenience of the light shining into your neighbours windows etc. Please see Selecting a Location for information on choosing the optimum location for your lantern

14 TOP VIEW A B Less sensitive 140º 180º SIDE VIEW More sensitive 1.8m 2m 8m Align arrow with slot in sleeve Close up of retaining clip C Insert terminal screwdriver here to remove module from lantern

15 D E 45 degrees 45 degrees LENS pointing forward LENS WILL ROTATE 45 degrees left and 45 degrees right when fully inserted into lantern

Lantern Receiver E-997 INSTALLER GUIDE. SF-LA-BC-RX-W.qxd 13/04/ :36 Page 1

Lantern Receiver E-997 INSTALLER GUIDE. SF-LA-BC-RX-W.qxd 13/04/ :36 Page 1 SF-LA-BC-RX-W.qxd 13/04/2005 13:36 Page 1 Lantern Receiver E-997 INSTALLER GUIDE V1.0-04/05 IQLA-BC-RX-W IQ Europe Limited Sandbeck Lane, Wetherby LS22 7TW. Visit us at www.iq-europe.co.uk Installation

More information

Security Light Transmitter

Security Light Transmitter SF-PTV180-150-T.qxd 13/04/2005 13:48 Page 1 Security Light Transmitter E-995 INSTALLER GUIDE V1.0-04/05 IQ-PTV180-150-TX-T IQ Europe Limited Sandbeck Lane, Wetherby LS22 7TW. Visit us at www.iq-europe.co.uk

More information

2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS

2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS 2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS SLB2000 PIR LIGHT CONTROLLER - BLACK WEATHERPROOF IP44 PIR SWITCHING 2000w MAXIMUM MANUAL ON/OFF OVERRIDE TIME

More information

60W Multi PIR Bulkhead

60W Multi PIR Bulkhead 60W Multi PIR Bulkhead Model: MLB98 Black Installation & Operating Instructions 1. General information: The unit utilises passive infrared technology to detect heat radiation of moving human bodies. Upon

More information

Model: MLSA360N. Installation & Operating Instructions. 360º Night Eye PIR Light Controller

Model: MLSA360N. Installation & Operating Instructions. 360º Night Eye PIR Light Controller Model: MLSA360N Installation & Operating Instructions 360º Night Eye PIR Light Controller Motion Sensor Detection Perspective View 5 metre 1 Ceiling Mount Position 0º Sensor Tilt Up 3º 3º 5 metre Sensor

More information

Chime Receiver E-996 INSTALLER GUIDE. SF-DCC-RX.qxd 13/04/ :30 Page 1

Chime Receiver E-996 INSTALLER GUIDE. SF-DCC-RX.qxd 13/04/ :30 Page 1 SF-DCC-RX.qxd 13/04/2005 13:30 Page 1 Chime Receiver E-996 INSTALLER GUIDE V2.0-02/05 IQ-DCC-RX-W IQ Europe Limited Sandbeck Lane, Wetherby LS22 7TW. Visit us at www.iq-europe.co.uk Installation helpline

More information

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

For assistance with the product please contact: HELPLINE. For a product brochure please contact: For assistance with the product please contact: HELPLINE 020 8450 0515 or email helpline@timeguard.com For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2

More information

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

For assistance with the product please contact: HELPLINE. For a product brochure please contact: For assistance with the product please contact: HELPLINE 020 8450 0515 or email helpline@timeguard.com For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2

More information

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS 360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER Cat No. SLFM360 INSTALLATION & OPERATING INSTRUCTIONS 1 Introduction The SLFM360 utilises passive infrared technology to detect heat radiation of moving human

More information

Surface Mount Wall PIR Light Controller. Model: PDWM1500. Installation & Operating Instructions

Surface Mount Wall PIR Light Controller. Model: PDWM1500. Installation & Operating Instructions Surface Mount Wall PIR Light Controller Model: PDWM1500 Installation & Operating Instructions 1. Introduction The PDWM1500 utilises passive infrared technology to detect heat radiation of moving human

More information

Model: PDSM1500. Installation & Operating Instructions 360º Surface Mount Ceiling PIR Light Controller

Model: PDSM1500. Installation & Operating Instructions 360º Surface Mount Ceiling PIR Light Controller Model: PDSM1500 Installation & Operating Instructions 360º Surface Mount Ceiling PIR Light Controller Considerate Lighting pollution bythe incorrectly installing a unit an or area Please be caused aware

More information

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS DETECTOR TRANSMITTER Cat No. TLTX2000B INSTALLATION & OPERATING INSTRUCTIONS 1 Introduction The TLTX2000B Controller Transmitter is part of the Timeguard range of PIR products which communicate by radio

More information

360º Surface Mount Ceiling PIR Light Controller

360º Surface Mount Ceiling PIR Light Controller 360º Surface Mount Ceiling PIR Light Controller Model: PDRS1500 Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference

More information

Model: PDFM1500. Installation & Operating Instructions 360º Flush Mount Ceiling PIR Light Controller

Model: PDFM1500. Installation & Operating Instructions 360º Flush Mount Ceiling PIR Light Controller Model: PDFM1500 Installation & Operating Instructions 360º Flush Mount Ceiling PIR Light Controller can cause to your immediateneighbours.light pollution caused by incorrectly installing a unit or over-lighting

More information

5W LED Energy Saver PIR Bulkhead

5W LED Energy Saver PIR Bulkhead 5W LED Energy Saver PIR Bulkhead Model: LED88PIR Black Installation & Operating Instructions 1. General information: The unit utilises passive infrared technology to detect heat radiation of moving human

More information

360 Surface Mount Ceiling PIR Light Controller

360 Surface Mount Ceiling PIR Light Controller 360 Surface Mount Ceiling PIR Light Controller Model: SLW360L Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference

More information

360 Ceiling PIR Light Controller

360 Ceiling PIR Light Controller 360 Ceiling PIR Light Controller Model: SLFM360L Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference and maintenance.

More information

60W Security Spotlight. 754HB1/180/ Outdoor Motion Sensor. Installation Instructions. Please leave these instructions at the installation site.

60W Security Spotlight. 754HB1/180/ Outdoor Motion Sensor. Installation Instructions. Please leave these instructions at the installation site. 60W Security Spotlight 754HB1/180/60 180 Outdoor Motion Sensor Installation Instructions Please leave these instructions at the installation site. Contents 1.0 Introduction... 3 1.1 Features... 3 1.2 Wireless

More information

18W Round LED Wall/Ceiling Light with Microwave Sensor

18W Round LED Wall/Ceiling Light with Microwave Sensor 18W Round LED Wall/Ceiling Light with Microwave Sensor Model: LEDMR18WHMS Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further

More information

12W Round LED Wall/Ceiling Light with Microwave Sensor

12W Round LED Wall/Ceiling Light with Microwave Sensor 12W Round LED Wall/Ceiling Light with Microwave Sensor Model: LEDSR12WHMS Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further

More information

30W LED PIR FLOODLIGHT. Model: LEDX30PIRB Model: LEDX30PIRWH

30W LED PIR FLOODLIGHT. Model: LEDX30PIRB Model: LEDX30PIRWH 30W LED PIR FLOODLIGHT Model: LEDX30PIRB Model: LEDX30PIRWH 1. Designated Use LEDX30PIR is an outdoor motion detector for automatic LED lighting control. Mainly for wall installation. Simple plug in wall

More information

Compact Movement Activated Sensor Installation Instructions

Compact Movement Activated Sensor Installation Instructions MAL540 Instructs. 12/7/06 3:43 PM Page 3 Compact Movement Activated Sensor Installation Instructions MAL540 series 2 Where to fit your Security Sensor To achieve best results for outside use the Arlec

More information

BATTERY POWERED DETECTOR/ TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTXDCB INSTRUCTIONS

BATTERY POWERED DETECTOR/ TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTXDCB INSTRUCTIONS BATTERY POWERED DETECTOR/ TRANSMITTER Cat No. TLTXDCB INSTALLATION & OPERATING INSTRUCTIONS 1 Introduction The TLTXDCB Battery Powered Detector/Transmitter is part of the Timeguard range of PIR products

More information

High Frequency Sensor

High Frequency Sensor Model: HF1 Installation & Operating Instructions High Frequency Sensor 1. Specifications: 1. Power: AC 220 ~ 240V 50MHz. 2. Sensor Technology: 5.8GHz High Frequency. 3. Switching capacity: 1000W Incandescent

More information

Installation and Safety Instructions Cone Wall Light with PIR Stainless Steel Model: S083S

Installation and Safety Instructions Cone Wall Light with PIR Stainless Steel Model: S083S Installation and Safety Instructions Cone Wall Light with PIR Stainless Steel Model: S083S These instructions are for your safety. Please read through them thoroughly before use and retain for future reference.

More information

GI1DPC/B User Guide. Mains tungsten GLS filament or halogen lamp Min 60W Max 300W. Linear fluorescent

GI1DPC/B User Guide. Mains tungsten GLS filament or halogen lamp Min 60W Max 300W. Linear fluorescent GI1DPC/B User Guide Single gang PIR Dimmer Replaces a standard light switch or dimmer Turns off automatically Turns on automatically Security mode Night light mode* Scene setting and soft on/off* * only

More information

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series Installation Instructions Contents 1.0 Product Range...3 2.0 Principle of Operation...3 3.0 Field of View...3 4.0 System Components

More information

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2 II112918-SL Installation Guide VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2 TECHNICAL DATA Rated voltage: 220V-240V~ 50/60Hz Load: Load 1( /T1) for Lighting Incandescent: Max.

More information

pond and garden LED feature light

pond and garden LED feature light Established over 50 years ago, Blagdon are committed to producing a comprehensive range of high quality, easy to use, pond equipment. An ongoing programme of research and development ensures excellent

More information

Cover. Contents of Spare Parts: CAUTION: In case of damaged or missing parts, please call toll-free at

Cover. Contents of Spare Parts: CAUTION: In case of damaged or missing parts, please call toll-free at In case of damaged or missing parts, please call toll-free at -800-887-6326 Contents of Spare Parts: Assembly Kit ( SET) (4805MM For 356-2826) (4808MM For 356-95) ecorative Cap Nut (4 PCS) (4805CT For

More information

Indoor Infrascan Passive Infrared Motion Sensor. Series. Installation Instructions. Please leave these instructions at the installation site.

Indoor Infrascan Passive Infrared Motion Sensor. Series. Installation Instructions. Please leave these instructions at the installation site. Indoor Infrascan Passive Infrared Motion Sensor 751 Series Installation Instructions Please leave these instructions at the installation site. Table of Contents 1.0 Product Range...3 2.0 Description...3

More information

, ,

, , 796-2028, 796-2021, 796-2025 Batten mount PIR detectors Overview This series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Ceiling PIR HS presence detector. Product Guide. Overview. Features Product Guide 796-2047 Ceiling PIR HS presence detector Overview The 796-2047 (passive infrared) presence detector provides automatic control of lighting loads with optional manual control. This is a high

More information

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR DESCRIPTI & FEATURES With High Frequency Occupancy On/ Off Sensor ; HF System: 5.8GHz±75MHz, ISM wave band Sensor Power consumption : 0.5W(- standby);

More information

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH) USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH) Logic Heat H / Logic Max Heat H / Logic System S / Logic Max System S / Vogue System / Vogue Max System Contents Introduction...

More information

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215 SECURITY LIGHT MODEL NO: CL6PIR PART NO: 4003535 OPERATION INSTRUCTIONS GC0215 INTRODUCTION Thank you for purchasing this CLARKE Security Light with motion sensor. The motion sensor is a small electronic

More information

Compact Cyclonic Bagless Cylinder Vacuum Cleaner

Compact Cyclonic Bagless Cylinder Vacuum Cleaner Compact Cyclonic Bagless Cylinder Vacuum Cleaner Model Number: RHCV35BM01 220-240V AC 50/60Hz 700W For Customer Services & Spare Parts please call 0345 209 7461 Opening times: Monday - Friday 8am 8pm &

More information

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER TOCR0 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER SAFETY PRECAUTIONS Be sure to switch off power source before installing. Make sure that the power wiring comes from circuit with an external 16A miniature

More information

Compact Cyclonic Pro Bagless Cylinder Vacuum Cleaner

Compact Cyclonic Pro Bagless Cylinder Vacuum Cleaner Compact Cyclonic Pro Bagless Cylinder Vacuum Cleaner Model Number: RHCV15SB05 220-240V AC 50/60Hz 1000W For Customer Services & Spare Parts please call 0345 209 7461 Opening times: Monday - Friday 8am

More information

. w. POWERHOUSE n MOTION DETECTOR MODEL PR511 OWNER S MANUAL

. w. POWERHOUSE n MOTION DETECTOR MODEL PR511 OWNER S MANUAL 8s. w POWERHOUSE n MOTION DETECTOR MODEL PR511 OWNER S MANUAL INTRODUCTION A QUICK LOOK AT YOUR MOTION DETECTOR Your X-10 POWERHOUSE TM Motion Detector gives your home a lived-in look when you are away,

More information

Programmable Security Light Switch

Programmable Security Light Switch Programmable Security Light Switch Model: ZV210 (Single) Model: ZV215 (Double) Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for

More information

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide PIR/INT & PIR/INT-D Batten mount PIR detectors Overview The PIR/INT & PIR/INT-D miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional

More information

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor. Product Guide EBDSM-DD Ceiling PIR presence detector DALI / DSI dimming Overview The EBDSM-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

Single Cyclonic Cylinder Vacuum Cleaner

Single Cyclonic Cylinder Vacuum Cleaner Single Cyclonic Cylinder Vacuum Cleaner Model Number: RHCV3001 220-240V~, 50/60Hz, 800W For Customer Services & Spare Parts please call 0345 209 7461 Opening times: Monday - Friday 8am 8pm & Saturday 9am

More information

OWNERS INSTRUCTION MANUAL

OWNERS INSTRUCTION MANUAL OWNERS INSTRUCTION MANUAL 132CM/52 Classic INSTALLATION OPERATION MAINTENANCE CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. IF UNSURE CONSULT A QUALIFIED ELECTRICIAN SUITABLE

More information

Motion Sensor. Specifications

Motion Sensor. Specifications Used for motion activated and dusk to dawn lighting control of flood lights, area lights, etc. Durable weatherproof construction utilizing infrared technology to sense temperature changes caused by movement

More information

PMCSF6 OCCUPANCY SENSOR

PMCSF6 OCCUPANCY SENSOR PMCSF6 OCCUPANCY SENSOR Lens Main Body Power Cord INTRODUCTION The use of occupancy detectors in commercial and industrial applications can significantly reduce energy usage lessening both energy costs

More information

CR9934 ROBERTS. PLL Dual Alarm Clock Radio. Sound for Generations. Please read this manual before use

CR9934 ROBERTS. PLL Dual Alarm Clock Radio. Sound for Generations. Please read this manual before use ROBERTS Sound for Generations CR994 PLL Dual Alarm Clock Radio Please read this manual before use Contents Contents... Controls... - Display... 4 Connecting to mains supply... 5 Display backlight... 5

More information

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide EBMPIR-MB Batten mount PIR detectors Overview The EBMPIR-MB series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual

More information

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE DANESMOOR FRONT SERVICE (FS) 12-18, 18-25 FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE EXCELLENCE COMES AS STANDARD Thank you for purchasing a Danesmoor Front Servicing

More information

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDHS-AD-LT30 Ceiling PIR HS presence detector 1-10V, low temperature Overview The EBDHS-AD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads with

More information

48 TAYLOR CEILING FAN

48 TAYLOR CEILING FAN 48 TAYLOR CEILING FAN Owner s Manual Models #20554 If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-459-3267, 9 a.m.- 5 p.m.

More information

PRODUCT INFORMATION. Uses tough, high quality PC diffuser, resistant to fracture and to ultraviolet light to limit discolouring.

PRODUCT INFORMATION. Uses tough, high quality PC diffuser, resistant to fracture and to ultraviolet light to limit discolouring. Ø297mm Packing list in Ceiling Mount Lamp LEDS 96PCS Φ6 Wall plug 3x30 Screw Φ3 Sealing ring 4x12 Y type Stainless Screw Quantity 1X 4X 4X 3X 3X PRODUCT INFORMATION 98.5mm Ideal for energy saving this

More information

Turbo Cyclonic Pro Bagless Cylinder Vacuum Cleaner

Turbo Cyclonic Pro Bagless Cylinder Vacuum Cleaner Turbo Cyclonic Pro Bagless Cylinder Vacuum Cleaner Model Number: RHCV20MR04 220-240V~, 50/60Hz, 900W For Customer Services & Spare Parts please call 0345 209 7461 Opening times: Monday - Friday 8am 8pm

More information

INDOOR INFRASCAN. Passive Infrared Motion Sensors 751 SERIES INSTALLATION MANUAL. Please leave these instructions at the installation site

INDOOR INFRASCAN. Passive Infrared Motion Sensors 751 SERIES INSTALLATION MANUAL. Please leave these instructions at the installation site INDOOR INFRASCAN Passive Infrared Motion Sensors 751 SERIES INSTALLATION MANUAL Please leave these instructions at the installation site Contents Section...Page 1 Product Range...3 2 Description...3 3

More information

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi Contents Introduction... Ideal Touch kit contents...

More information

Quick start guide. Connected wireless room thermostat. Logic Combi C / Logic Max Combi C / Vogue Gen 2 Combi / Vogue Max Combi

Quick start guide. Connected wireless room thermostat. Logic Combi C / Logic Max Combi C / Vogue Gen 2 Combi / Vogue Max Combi Quick start guide Connected wireless room thermostat Logic Combi C / Logic Max Combi C / Vogue Gen 2 Combi / Vogue Max Combi Introduction Welcome to the Ideal Touch quick start guide. This guide is designed

More information

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves Installation & Operating Instructions Models: York Midi & Serrano Electric Stoves PLEASE NOTE THAT THIS APPLIANCE USES A MOTOR TO OPERATE THE FLAME EFFECT AND THAT IT MAY BE POSSIBLE TO HEAR IT WHERE THE

More information

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE ITM. / ART. 1165831 Model: LM56123 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY For assistance with assembly or installation,

More information

CHIME RECEIVER INSTALLATION & OPERATING. Cat No. TLRXC1 INSTRUCTIONS

CHIME RECEIVER INSTALLATION & OPERATING. Cat No. TLRXC1 INSTRUCTIONS CHIME RECEIVER Cat No. TLRXC1 INSTALLATION & OPERATING INSTRUCTIONS 1 Introduction The TLRXC1 Chime Receiver is part of the Timeguard range of PIR products which communicate by radio frequency (r.f.) signals.

More information

Installation and User Guide. Electro-mechanical mini programmer for controlling hot water and heating Including Factory Replacement Units (FRU)

Installation and User Guide. Electro-mechanical mini programmer for controlling hot water and heating Including Factory Replacement Units (FRU) 102 Electro-mechanical mini programmer for controlling hot water and heating Including Factory Replacement Units (FRU) Danfoss Heating Installation and User Guide Index Installation Product specification

More information

Motion tracking. sensor led light. Installation & operating manual NIGHTWATCHER. Model no: nw1200x

Motion tracking. sensor led light. Installation & operating manual NIGHTWATCHER. Model no: nw1200x Motion tracking sensor led light Installation & operating manual NIGHTWATCHER Model no: nw1200x 1 INTRODUCTION Congratulations on the purchase of your new Nightwatcher Security Light. Before installation

More information

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration in tap Boiling water to in tap sink Drain Valve (as high as possible) REDITAP CONNECTION SUMMARY Amp mains supply cold mains water into in tap optional filter cold water in hot water BOILING UNIT Installation

More information

Electric Cooker. Important Please read these instructions fully before installing or using

Electric Cooker. Important Please read these instructions fully before installing or using Electric Cooker Installation & User Instructions - Please keep for future reference Cat no Model 2679556 BUSH BET50W WHITE 2441935 BUSH BET50B BLACK 3596669 BUSH BET50S SILVER Cooker serial number place

More information

PERFORMANCE SLIMMING BELT

PERFORMANCE SLIMMING BELT YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY PERFORMANCE SLIMMING BELT MODEL C90007 1 TECHNICAL DATA Description: Performance Slimming Belt Model: C90007 Rated Voltage: 220-240V Power: DC 12V

More information

Owner s Manual Compact Fluorescent Lunar Aqualight

Owner s Manual Compact Fluorescent Lunar Aqualight Owner s Manual Compact Fluorescent Lunar Aqualight Aquarium Light Fixture Featuring: Directional Lunar Blue LEDs IMPORTANT SAFETY INSTRUCTIONS WARNING: To guard against injury, basic safety precautions

More information

INSTALLATION & USER INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS INSTALLATION & USER INSTRUCTIONS LED ELECTRIC STOVE Christchurch, Dorset BH23 2BT Tel: 01202 588 638 Fax: 01202 499 639 www.ekofires.co.uk e-mail: sales@ekofires.co.uk MODELS COVERED BY THESE INSTRUCTIONS

More information

1/2011 V1. Puzer AINO USER MANUAL. Read this instruction before using the vacuum cleaner! Keep the instructions near the vacuum cleaner for later use!

1/2011 V1. Puzer AINO USER MANUAL. Read this instruction before using the vacuum cleaner! Keep the instructions near the vacuum cleaner for later use! Puzer AINO USER MANUAL Read this instruction before using the vacuum cleaner! Keep the instructions near the vacuum cleaner for later use! 1 Vacuum cleaner parts 1 Part numbers 1. Wall inlet 2. Display

More information

18 INCHES, OSCILLATING STAND FAN

18 INCHES, OSCILLATING STAND FAN To Buy: Contact Sylvane at 800-934-9194 or visit www.sylvane.com For Product Support: Contact Soleus Air at (888) 876-5387 18 INCHES, OSCILLATING STAND FAN OWNER S MANUAL Model # FSM-45 PLEASE READ AND

More information

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W 10L Dehumidifier Model Number: LDH1001 220-240V AC 50/60Hz 290W For Customer Services & Spare Parts please call 0345 209 7461 Opening times: Monday - Friday 8am 8pm & Saturday 9am 1pm Or visit us at www.productcare.co.uk

More information

LPCMPIRM65 & LPCMPIRDSI65

LPCMPIRM65 & LPCMPIRDSI65 Product Guide LPCMPIRM65 & LPCMPIRDSI65 Luminaire high mount PIR detectors Overview The LPCMPIR PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

52 STRATHMERE CEILING FAN

52 STRATHMERE CEILING FAN 52 STRATHMERE CEILING FAN Owner s Manual Models #20341 If a problem cannot be remedied or you are experiencing difficulty with installation, please contact the Service Department: 1-877-459-3267, 9 a.m.-

More information

getting the best from your new cleaner...

getting the best from your new cleaner... 8407 Upright ib Comet 5 03/12/2002 1:28 PM Page 1 Ultralight vacuum cleaner Please read and keep these instructions getting the best from your new cleaner... If your cleaner isn t picking up as well as

More information

Owner s Manual. High Output T5 Lunar Aqualight. Aquarium Light Fixture. Featuring: Directional Lunar Blue LEDs

Owner s Manual. High Output T5 Lunar Aqualight. Aquarium Light Fixture. Featuring: Directional Lunar Blue LEDs Owner s Manual High Output T5 Lunar Aqualight Aquarium Light Fixture Featuring: Directional Lunar Blue LEDs OwnMan_T5HO_LUNAR.indd 1 6/15/10 10:06 AM IMPORTANT SAFETY INSTRUCTIONS WARNING: To guard against

More information

Compact Cyclonic Bagless Upright Vacuum Cleaner

Compact Cyclonic Bagless Upright Vacuum Cleaner Compact Cyclonic Bagless Upright Vacuum Cleaner Model Number: RHUV20MR05 For Customer Services & Spare Parts please call 0345 209 7461 Opening times: Monday - Friday 8am 8pm & Saturday 9am 1pm Or visit

More information

Safety and Instruction Manual

Safety and Instruction Manual T12010 Safety and Instruction Manual PLEASE READ CAREFULLY 1200W Stand Mixer T12010 Stand Mixer TECHNICAL DATA Description: Stand Mixer Model: T12010 Rated Voltage: 220V-240V ~ 50Hz Power Consumption:

More information

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.) Excel Lighting & Manufacturing Ltd. Lifetime Limited Warranty Excel Lighting & Manufacturing Ltd. Warrants the fan motor to be free from defects in workmanship and material present at time of shipment

More information

User Guide. Please read carefully before use. Your Hoover Guarantee. Your Hoover Guarantee. Contents. IMPORTANT Safety Reminders

User Guide. Please read carefully before use. Your Hoover Guarantee. Your Hoover Guarantee. Contents. IMPORTANT Safety Reminders Your Hoover Guarantee Contents Your Hoover Guarantee During year 1 HOOVER engineers will replace or repair all defective parts free of charge, except for parts subject to fair wear and tear such as belts,

More information

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDSPIR-HB-AD High bay PIR presence detector 1-10V dimming Overview The EBDSPIR-HB-AD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

Turbo Lite Corded Handheld Stick Vacuum

Turbo Lite Corded Handheld Stick Vacuum Turbo Lite Corded Handheld Stick Vacuum Model Number: RHCHS1001 For Customer Services & Spare Parts please call 0345 209 7461 Opening times: Monday - Friday 8am 8pm & Saturday 9am 1pm Or visit us at www.productcare.co.uk

More information

Installation and User Guide. Electro-mechanical 24 hour timeswitch for controlling hot water and heating (Including Factory Replacement Units FRU)

Installation and User Guide. Electro-mechanical 24 hour timeswitch for controlling hot water and heating (Including Factory Replacement Units FRU) 103 Electro-mechanical 24 hour timeswitch for controlling hot water and heating (Including Factory Replacement Units FRU) Danfoss Heating Installation and User Guide Index Installation Product specification

More information

WASH FILTER REGISTER YOUR FREE 2 YEAR GUARANTEE TODAY OPERATING MANUAL ASSEMBLY. click. click. Wash filter with cold water at least every month.

WASH FILTER REGISTER YOUR FREE 2 YEAR GUARANTEE TODAY OPERATING MANUAL ASSEMBLY. click. click. Wash filter with cold water at least every month. OPERATING MANUAL ASSEMBLY click 2 click 3 1 WASH FILTER Wash filter with cold water at least every month. FULLY CHARGED YOUR FREE 2 YEAR GUARANTEE TODAY After registering for your free 2 year guarantee,

More information

PHOTECH AMPHIBIOUS PA35/PA320/PA520 THE POND MASTERS GUIDE TO. Blagdon - The Pond Masters The name you can rely on

PHOTECH AMPHIBIOUS PA35/PA320/PA520 THE POND MASTERS GUIDE TO. Blagdon - The Pond Masters The name you can rely on Established over 40 years ago, Blagdon are committed to producing a comprehensive range of high quality, easy to use, pond equipment. An ongoing programme of research and development ensures excellent

More information

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual keeping your home safe and clean USERS MANUAL Desiccant Dehumidifier Model: ECO DD322FW SIMPLE Read This Manual Inside you will find many helpful hints on how to use and maintain your dehumidifier properly.

More information

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features Product Guide PPAD-C-230V Ceiling PIR presence/absence detector Overview The PPAD-C-230V passive infrared presence detector provides automatic control of lighting loads with optional manual control. The

More information

LED Lighting. Solutions

LED Lighting. Solutions LED Lighting Solutions Introducing the new range of LED outdoor Floodlights from Timeguard. They give instant brightness just like halogens but use only a fraction of the power. Save time, money and energy

More information

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver EBDSPIR-HB-DD Product Guide High bay PIR presence detector DALI / DSI dimming Overview The EBDSPIR-HB-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional

More information

2.9kW Portable Air Conditioner

2.9kW Portable Air Conditioner Operating Instructions 2.9kW Portable Air Conditioner Item: GCPAC210 General Care and Safety Guide Thank you for choosing this Goldair product. This Goldair appliance has been designed and manufactured

More information

getting the best from your new cleaner...

getting the best from your new cleaner... Topo compact vacuum cleaner Please read and keep these instructions getting the best from your new cleaner... If your cleaner isn t picking up as well as it should, please check Dustbags It is important

More information

HELPLINE If you have any difficulty with your appliance, do not hesitate to call us. Website

HELPLINE If you have any difficulty with your appliance, do not hesitate to call us. Website 44262 rev2:44262 12/11/2009 08:52 Page 1 Stale bread toasts more rapidly than fresh bread. Therefore, the browning control should be set at a lower setting than usual. All sorts of bread can be used as

More information

RadioLINK + Module EIB600MRF for Battery Powered Smoke / Heat Alarms EIB600 Series

RadioLINK + Module EIB600MRF for Battery Powered Smoke / Heat Alarms EIB600 Series RadioLINK + Module EIB600MRF for Battery Powered Smoke / Heat Alarms EIB600 Series EIB600MRF Module (for use with EIB600 Series compatible Alarms only) Instructions Read and retain carefully for as long

More information

USER GUIDE MOTORISED LED FLOOD LIGHT CAN WE HELP?

USER GUIDE MOTORISED LED FLOOD LIGHT CAN WE HELP? Model #NW520 USER GUIDE MOTORISED LED FLOOD LIGHT CAN WE HELP? Questions, problems, missing parts? Before returning to the store call Nightwatcher Customer Service: 0845 900 6764 Or Email: support@nightwatchersecurity.co.uk

More information

ROBERTS. FM / MW dual alarm clock radio with instant time set. Please read this manual before use

ROBERTS. FM / MW dual alarm clock radio with instant time set. Please read this manual before use ROBERTS FM / MW dual alarm clock radio with instant time set Please read this manual before use Contents Contents... 1 Controls...2-5 Switching on... 6 Setting the time manually... 6 Setting the year manually...

More information

getting the best from your new cleaner...

getting the best from your new cleaner... VC73360MUK-CyclonicBaglessRev3 3/11/05 4:41 pm Page 1 Cyclonic bagless vacuum cleaner Please read and keep these instructions getting the best from your new cleaner... If your cleaner isn t picking up

More information

Silent TS. Nr / Ideas for dental technology / A. Made in Germany

Silent TS. Nr / Ideas for dental technology / A. Made in Germany Silent TS Nr. 2921-0050 / 2921-1050 21-9191 30102012 / A Made in Germany Ideas for dental technology 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Silent TS Nr. 2921-0050

More information

WHAT IS ENERGY+ILLAWARRA? WHAT DO YOU MEAN WHO IS INVOLVED IN ENERGY+ILLAWARRA? ENERGY+ILLAWARRA?

WHAT IS ENERGY+ILLAWARRA? WHAT DO YOU MEAN WHO IS INVOLVED IN ENERGY+ILLAWARRA? ENERGY+ILLAWARRA? WHAT IS ENERGY+ILLAWARRA? ENERGY+ILLAWARRA is a program developed with the community, for the community. It aims to support energy efficiency in the home, without sacrificing comfort or well-being. The

More information

CARMEL 48 CEILING FAN

CARMEL 48 CEILING FAN CARMEL 48 CEILING FAN MODELS #50196, 50197 Español p. 21 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883, Monday - Thursday,

More information

Integrated PIR detectors

Integrated PIR detectors EBMINT - Product Guide Integrated PIR detectors Overview The EBMINT series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

INSTALLATION & USER INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS INSTALLATION & USER INSTRUCTIONS LED ELECTRIC STOVE Christchurch, Dorset BH23 2BT Tel: 01202 588 638 Fax: 01202 499 639 www.ekofires.co.uk e-mail: sales@ekofires.co.uk MODELS COVERED BY THESE INSTRUCTIONS

More information