1 GWINNETT COUNTY Department of Fire & Emergency Services Office of the Fire Marshall S001 Access Aisle (Car) S005 S010 S015 S020 S025 S030 S035 S040 S045 S050 S055 S060 S065 S070 S075 S080 S085 Access Aisle (Van) Address (Flow Test) Water Mains (Location & Sizes) Building Entrances Building, Facilities, Element Curb Ramps (Built-up) Curb Ramps (Location/Detail) Ramps (Cross Slope and Surface) Curb Ramps (Slope) Curb Ramps (Surface) Curb Ramps (Width) Dead End Road Way (150 ft) Designated Fire Lanes Curb Ramps (Diagonal) Ramps (Edge Protection) FDC (150 ft from Hydrant) CASE TYPE : FIR CONDITIONS : SITE (Automobile Access Aisle) shall be a minimum of 5 ft wide, a common access aisle may be shared by 2 vehicles. Surface slopes shall not exceed 1:50(2%) in any direction. Georgia (A detail can be downloaded (Van Access) aisle shall be a minimum of 8 ft wide. A common access aisle may be shared by 2 vehicles. The access aisle shall be to the right of the van parking space. Surface slopes shall not exceed 1:50(2%). Rule (3). Georgia (A detail can be downloaded An (Address) to include a Numerical and Street name designation shall be provided. International Fire Code, Chapter 5, Section 505.1, 2006 Edition. Provide a (Flow Test) certified by the appropriate water department on the nearest fire hydrant to the proposed building is required if the existing main size is 8 inch inside diameter. Minimum flow to be 1250 gpm with a residual of 20 psi. If existing main is 6 inch, the minimum flow is to be 1000 gpm with a residual of 20 psi. Gwinnett County Ordinance For Fire Protection And Life Safety, Section 46-37(d)(3). (Water Main) location and sizes are to be shown on plan. (Entrances) to the Building in new construction shall be provided per the requirements of Rule (8) (a-d). Accessible entrances must be provided in a number at least equivalent to the number of exits required by the applicable building/fire codes. (This paragraph does not require an increase in the total number of entrances planned for a facility.) Georgia At least one (Accessible Route) complying with Rule shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site (b) Georgia (Built up curb ramps) shall be provided per the requirements of Rule (6), built-up curb ramps are not allowed in the parking access aisle. Georgia (Curb Ramps) shall be provided per the requirements of Rule Georgia Show Curb Ramp location on plans.(a detail can be downloaded (Cross Slope & Surfaces) shall comply With Georgia (Slope of Curb Ramps) shall comply with the requirements of Rule (2), Georgia (Surfaces of Curb Ramps) shall comply with Rule Georgia The (Minimum Width) of a curb ramp shall be 36 inches, exclusive of flared sides. Rule (3). Georgia Every (Dead-End Access Roads) in excess of 150 feet in length shall be provided with an approved area for turning around fire apparatus. International Fire Code, Chapter 5, Section , 2006 Edition. (A detail can be downloaded (Fire Lanes) shall be installed in streets or roads adjacent to buildings, on at least one side which presents major point(s) of access into the building. International Fire Code, 2006 Edition. Gwinnett County Ordinance For Fire Protection And Life Safety, Section (Diagonal Curb Ramps) shall comply with the requirement of (10). Georgia (Edge Protection) shall be provided per (7). Georgia Accessibility (Sprinkler Connection) for fire department use is to be a maximum of 150 ft from a fire hydrant on an 8 inch water main. The connection shall be between 18 inches and 40 inches above ground level. Authority Having Jurisdiction. 1 of 5
2 S090 S095 S100 S102 S105 S110 S115 S120 S125 S130 S135 S140 S145 S150 S155 S156 S160 S165 S170 FDC (Location shown on plans) FDC (Underground Contractor) FDC (check valve, auto-drip,sign) PIV (Omission of Valve) Fire Hydrant (Location) Fire Hydrant (Placement) Fire Hydrant (Installed, Flushed) Fire Hydrant Spacing (Single Fami Fire Hydrant Spacing (Muti-Family Fire Hydrant Spacing (Ind. & Comm Fire Lane Signage and Marking Grade Max (10%) Ground & Floor Surface Ramps (Handrails) All weather roadway 75,000 lb. Approved Fire Access Roads 150' Curb Ramps (Islands) Ramps (Landings) Location H/C parking spaces (Fire Department Sprinkler Connection) locations shall be shown on the site plan. Note on the site plan that a Georgia Certificate of Competency holder for automatic fire sprinkler systems will be responsible for the design and installation of the underground supply piping. (Installation or Repair) of Underground Fire Sprinkler water supplies shall be performed by a utility or fire sprinkler contractor or plumbing contractor licensed under Chapter 11 Title 25 Section (Fire Department Connections) if installed underground shall have a listed check valve, an auto-drip valve, a sign on a plate or fitting reading, "Auto-Sprinkler or Auto-Sprinkler/Standpipes", and hose connections shall have standard threads as specified in NFPA Post Indicator Valves (PIV) in the underground piping shall be omitted unless specifically permitted by the Gwinnett County Fire Marshal's Office. (Hydrant) locations are to be shown on plans. (Placement of Fire Hydrants) shall be a minimum of 3 ft. and a maximum of 15 ft. from the back of the curb or road edge with the large fire department connection facing the nearest fire department access point and set a minimum of 18" and a maximum of 36" above finished grade to the center of the large fire department connection. Authority Having Jurisdiction. (Fire Hydrants and Water Mains) are to be installed, flushed and under pressure before any combustible construction is started. Gwinnett County Ordinance For Fire Protection And Life Safety, Section 46-38(a). (Fire Hydrants) in Single Family Residential shall be spaced no more than 450 ft. apart. Gwinnett County Ordinance For Fire Protection and Life Safety, Section 46-37(a). (3-way Fire Hydrants) in Multi Family residential subdivisions shall be located such that all portions of the building can be reached by fire hose lays not to exceed 400 ft. Gwinnett County Ordinance For Fire Protection And Life Safety, Section 46-37(c). (Fire Hydrant Spacing) in Industrial & Commercial developments shall not exceed 300 ft along dedicated roadways. Additional hydrants may be required to permit all portions, of all buildings, to be reached by hose lays not to exceed 400 ft by road travel. Gwinnett County Ordinance For Fire Protection And Life Safety, Section 46-37(c). (Marking and Signage) of Fire Lanes shall be provided per the requirements of The International Fire Code, Chapter 5, Section 503.3, 2006 Edition. Gwinnett County Ordinance For Fire Protection And Life Safety, Section 46-65(c)(1)(2). (Grades) shall be no more than 10%. International Fire Code, 2006 Edition, Section (Ground & Floor Surfaces) along accessible routes and walks, ramps, stairs, and curb ramps, shall be stable, firm, slip-resistant, and shall comply with Rule &19. Georgia (Handrails) shall be designed per (5a through 5i). Georgia "Note on Plan" During construction and for Permanent Access, roadways constructed of an all weather surface capable of supporting 75,000 pounds gross weight shall be provided per International Fire Code, Chapter 5, Section , 2006 Edition. Approved Fire Apparatus Access Roads shall be provided for every facility, building or portion of a building. The fire apparatus access road shall extend to within 150 feet of all portions of the facility or any portion of the exterior wall of the first story of the building as measured by an approved route around the exterior of the building or facility. International Fire Code, Chapter 5, Section , 2006 Edition. (Islands) in the roadway shall be made accessible per the requirements of (11). Georgia (Landings) shall be designed per Rule (4a through 4d). Georgia (Location) of accessible parking spaces shall be provided per (2). Georgia 2 of 5
3 S175 S180 S185 S190 S195 S200 S205 S210 S215 S220 S225 S230 S235 S240 S245 S250 S255 S260 S265 S266 S270 Max. Slope parking & access Curb Ramps (Marked Crossing) Number of H/C Parking Spaces Curb Ramps (Obstructions) Ramps (Outdoor Conditions) Passenger Loading Zones 60" Passing Space Protruding Objects Ramps (Required) Ramp (Detail) Road Edge From Structure Roadway Width (One Way 14 ft) Ramps (Clear Width) Security Gate Installation Self Service Gasoline Plans Curb Ramps (Sides) H/C Parking Signage H/C Signage (Detail) Site Plan (Appears OK) Site Plan (All Comments) Site Plan (3 complete sets) The (Maximum Slope) of the accessible parking spaces & access aisles shall be 2% in all directions. (Curb Ramps) at Marked Crossings shall be wholly within the markings excluding flared sides. Signage shall be located so it cannot be obstructed by a vehicle. Rule (9). Georgia (Accessible Parking Spaces) shall be provide in the amount per the requirements of (e)1, (e)2, (e)4, (e)5. (Curb Ramps) shall be located or protected to prevent their obstruction by parked vehicles. Rule (8). Georgia (Outdoor Ramps & Their Approaches) shall be designed so that water will not accumulate on walking surfaces per (8). Georgia Accessibility (Passenger Loading Zones) shall be provided per the requirements of (6). Georgia If an (Accessible Route) has less than 60 inches clear width, then passing spaces at least 60 inches by 60 inches shall be located at reasonable intervals not to exceed 200 ft. A T - intersection of two corrdors or walks is an acceptable passing place. Rule (4). Georgia Accessibility (Objects) projecting from walls, (for example, telephones) with their leading edges between 27 inches and 80 inches above the finished floor shall protrude no more than 4 inches to walks, halls, corridors, passage ways, or aisles. Rule Georgia Ramps shall be provided where required by rule (1). Georgia Place ramp details on the plans. (A detail can be downloaded from our website at (Fire Lanes) shall be at least 20 ft. in width with the road edge closest to the structure a minimum of 10 Ft. from the structure. Gwinnett County Ordinance For Fire Protection And Life Safety, Section (Access Road) width for one way roads shall be a minimum of 14 feet (SECURITY GATES ONLY). (Clear Width) of a ramp shall be 36 inches. Rule (3). Georgia (Security Gate Installation) shall be reviewed and permitted prior to installation. Installation shall comply with the Fire Marshal's General Order on "Security Gate Access" dated September 15, 2001.Gwinnett County Ordinance For Fire Protection And Life Safety, Section 46-43(a). International Fire Code, Chapter 5, Section 506, 2006 Edition. (Plans) for retail Self-Service gasoline operations shall be reviewed and permitted by the Georgia State Fire Marshal's Office Hazardous Material Section and a copy of the approvals shall be provided before final Certificate of Occupancy is issued. (Sides of Curb Ramps) shall be provided per the requirement of Rule (5). Georgia (Signage) shall be provided per the attached detail. "Van Accessible" shall be mounted immediately below the standard sign for van accessible spaces. Signs for Automobile accessible spaces shall be minimum of 60 inches to the bottom of the sign above finished grade. Signage for Van accessible spaces shall be a minimum of 84 inches to the bottom of the sign above finished grade. Rule (4). Georgia Place handicap signage detail on the plans. (A detail can be downloaded Site Plan appears to be okay as submitted. (FYI)**ALL COMMENTS** Shall be addressed on plans, NO PERMITS will be issued if any comments are outstanding. (FYI) Provide a minimum of three (3) complete sets of plans at the time of final review & approval. 3 of 5
4 S273 S275 S280 S285 S290 S295 S300 S305 S310 S315 S320 S325 S330 S335 S340 S345 S350 Site Plan (CD/Sets Required) Site Plan (6 months) Structure (Restrooms & Pump room) Site Plan (Town Homes) No Inspection Required Slope (accessible route) Ramps (Slope and Rise) Transportation, Building Entrance Curb Ramps (Detail) Water Main Size (Single Family) Water Main Size (Multi-Family) Water Main Size ( Ind.& Commerc 8" Min (Ind. & Comm. Projects) Underground Water Main (6" Tap) During construction/permanent 20' Vehicle Overhang (114 in.) Vertical Clearance (13ft 6in) Two (2) sets of complete site plans and One (1) CD are required for final plan approval. EACH PAGE OF THE PLANS SHALL BE IDENTIFIED ON THE CD AND MATCH THE PLANS. The plans on the CD shall bear the seal of an engineer, or a letter of authenticity. The CD should be in PDF or TIF format submitted in a jewel case. NOTE: Any revisions to the approved plans will require a revised CD for our records. (FYI) Please be advised that in order to keep our records current it has become standard procedure for the Engineering Plan Review Unit to purge files regularly. If there is no action toward addressing the review comments within the (6) month period following the initial review of this submittal, this review file will be discarded. (FYI) If the Structure only has restrooms and a pump room or storage room, no plan approvals or inspections are needed by this office. (FYI) Town Homes, separated by a (2) hour fire barrier, will be considered single family residential. This office requires no permits or inspections. (Permit Approvals and Inspections) are not required for this project by this office. Any (Accessible Route) with a running slope greater than 1:20 is a ramp and shall comply with rule Cross slope shall not exceed 1:50. Rule (7). Georgia (Slope & Rise) shall meet the requirements of (2). Georgia At least one (Accessible Route) complying with Rule shall be provided within the boundary of the site from public transportation stops, accessible parking spaces, passenger loading zones if provided, and public streets or sidewalks, to an accessible building entrance. Rule (a) Georgia Accessibility Code Place curb ramp detail on the drawings. (A detail can be downloaded from our website at (Water Mains) in Single Family residential subdivisions shall be 8" minimum inside diameter ductile iron pipe (DIP). Gwinnett County Ordinance For Fire Protection And Life Safety, Section 46-37(a). (Water Main) size in in Multi-Family residential subdivisions shall be a minimum or 8" inside diameter. Gwinnett County Ordinance For Fire Protection And Life Safety, Section 46-37(b). Exception: Hose lays may be extenced to 500 feet in fire sprinklered projects. (Water Main) size in Industrial and Commercial developments shall be a minimum of 12" diameter ductile iron pipe (DIP) with fire hydrant spacing not to exceed 300 ft along the street. Additional hydrants may be required to permit all portions, of all buildings, to be reached by hose lays not to exceed 400 ft by road travel. Fire Hydrants shall be (3) way type. Gwinnett County Ordinance For Fire Protection And Life Safety, Section 46-37(c). Exception: This shall not apply to private driveways giving access from a public way to three or less buildings totaling a maximum of 500,000 square feet. (FYI) The (Minimum Water Main) size, for Industrial & Commercial projects, shall be 8" from the point the main is tapped at the street until it ends. (FYI) The (Minimum Water Main) size may be 6 inch from the point the main is tapped until is ends, if the distance is not more than 50 feet. During construction and for permanent access, roadways width shall be 20 feet minimum per International Fire Code, Edition. Gwinnett County Ordinance For Fire Protection And Life Safety, Section 46-43(d). Provide (Minimum Vertical Clearance) of 114 inches at accessible passenger loading zones and along at least one vehicle access route to such areas from site entrance(s) and exit(s). At parking spaces complying with (e)(2), provide minimum vertical clearance of 98 inches at the parking space and along at least one vehicle access route to such spaces from site entrance(s) and exit(s). Rule (5). Georgia Accessibility (Clear Height) of access roadway shall be 13 ft. 6 in. minimum per International Fire Code, Chapter 5, Section , 2006 Edition. 4 of 5
5 S355 S360 Curb Ramps (Detectable Warnings) 36" Clear Width (Curb Ramps) shall have a detectable warning complying with Rule Detectable warning textures shall consist of truncated domes (grooves may be used indoors only). Texture shall contrast in color with the surrounding surface. The detectable warning shall extend the full width and 2 ft. depth of the curb ramp. Rule (7). Georgia The (Minimum Clear Width) of an accessible route shall be 36 inches except at doors. If a person in a wheelchair must make a turn around an obstruction, the minimum clear width of the accessible route shall comply with Rule (3), Fig. 7(a) and (b). Georgia 5 of 5
S000 SITE REVIEW APPR NO. FIRE CODE COMPLIANCE ITEM
APPR NO. FIRE CODE COMPLIANCE ITEM S000 S001 S005 (Automobile Access Aisle) shall be a minimum of 5 ft wide, a common access aisle may be shared by 2 vehicles. Surface slopes shall not exceed 1:50(2%)
More informationFire & Life Safety Requirements For Fire Department Access and Water Supplies
Fire & Life Safety Requirements For Fire Department Access and Water Supplies This brochure is being provided as a resource only. The items listed inside are the requirements most generally cited on plans
More informationCITY OF PASADENA FIRE DEPARTMENT
Page 1 of 8 CITY OF PASADENA FIRE DEPARTMENT INSTALLATION OF COMMERCIAL SPRINKLERS (Revised 12/10/2014) SCOPE: This standard applies to the design and installation of automatic fire sprinkler systems in
More informationFIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES
Established 1949 FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES The following are guidelines for new development. Any submitted plans must comply with these guidelines,
More informationThis guide is intended to provide assistance in the application of the fire code in all areas served by Tualatin Valley Fire & Rescue.
This guide is intended to provide assistance in the application of the fire code in all areas served by Tualatin Valley Fire & Rescue. North Operating Center 11945 SW 70 th Avenue Tigard, OR 97223 Phone:
More informationAUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)
AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations) This standard applies to the design and installation of automatic fire sprinkler systems in conjunction with
More informationSite Plans. Fire Code Requirements
Site Plans Fire Code Requirements Outline Before you start Critical building information drives requirements Access Requirements Access, aerial access, road design, remoteness, fire lanes, residential
More informationFIRE APPARATUS ACCESS AND WATER SUPPLY GUIDELINE
City of Conroe Fire Department Fire Marshal s Office 300 W. Davis 1 st Floor Conroe, Texas 77301 T: (936) 522-3080 F: (936) 522-3079 firecodes@cityofconroe.org FIRE APPARATUS ACCESS AND WATER SUPPLY GUIDELINE
More informationAUTOMATIC FIRE SPRINKLER SYSTEMS
MCKINNEY FIRE DEPARTMENT FIRE MARSHAL S OFFICE AUTOMATIC FIRE SPRINKLER SYSTEMS These guidelines are to be followed when a business, facility or organization installs an automatic fire sprinkler system
More informationEXHIBIT A STEAMBOAT SPRINGS FIRE PREVENTION SERVICES ADMINISTRATIVE POLICY & PROCEDURE MANUAL
EXHIBIT A STEAMBOAT SPRINGS FIRE PREVENTION SERVICES ADMINISTRATIVE POLICY & PROCEDURE MANUAL SECTION: 4 POLICY NO.: 1257.1 DATE: April 1, 2006 PAGE: 1 SUBJECT: Fire Apparatus Access Road Standards for
More informationNew Construction Fire Inspection Process
New Construction Fire Inspection Process This document is intended to provide the Owner, Designer, and/or Contractor of new construction with an outline of required fire inspections and with the specific
More informationEL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD
EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD INSTALLATION OF COMMERCIAL FIRE SPRINKLER SYSTEMS STANDARD #C-001 EFFECTIVE 03-25-2009 PURPOSE: To ensure that sprinkler plans submitted for review contain
More informationPLAN REVIEW SUBMITTAL GUIDE
PLAN REVIEW SUBMITTAL GUIDE Plans, specifications and other construction documentation for the initial plan review should be as complete as possible at the time of submittal. Use this convenient guide
More informationTETON COUNTY FIRE PROTECTION RESOLUTION FOR NEW SUBDIVISIONS 2008 Edition. Chapter I General Provisions
TETON COUNTY FIRE PROTECTION RESOLUTION FOR NEW SUBDIVISIONS 2008 Edition Chapter I General Provisions SECTION 1.1: TITLE. This Resolution shall be known as the Teton County Fire Protection Resolution
More informationTABLE OF CONTENTS ADOPTED FIRE CODES... 3 AFPD SERVICE AREA... 3 SITE AND DEVELOPMENT SUBMITTAL REQUIREMENTS... 4 PLAN REVIEW FEES...
TABLE OF CONTENTS ADOPTED FIRE CODES... 3 AFPD SERVICE AREA... 3 SITE AND DEVELOPMENT SUBMITTAL REQUIREMENTS... 4 PLAN REVIEW FEES... 4 SITE AND DEVELOPMENT PLAN REVIEW TURNAROUND TIMES... 4 DEVELOPMENT
More informationTAMARAC FIRE RESCUE DEPARTMENT FIRE PREVENTION BUREAU 6000 North Hiatus Road Tamarac, Florida Telephone: (954) , Fax: (954)
TAMARAC FIRE RESCUE DEPARTMENT FIRE PREVENTION BUREAU 6000 North Hiatus Road Tamarac, Florida 33321 Telephone: (954) 597-3800, Fax: (954) 597-3810 SITE PLAN REVIEW CHECKLIST A goal of the Tamarac Fire
More informationOXNARD FIRE DEPARTMENT 360 West Second Street Oxnard, CA (805) Fax (805)
OXNARD FIRE DEPARTMENT 360 West Second Street Oxnard, CA 93030 (805) 385-7722 Fax (805) 385-8009 REQUIREMENTS FIRE HYDRANT STANDARDS Fire hydrants and required access roads shall be provided prior to and
More informationLouisville Metro Ordinance (Chapter 94: Fire Prevention) FIRE HYDRANTS, WATER MAINS AND WATER SUPPLY.
Louisville Metro Ordinance (Chapter 94: Fire Prevention) To search for all Metro Ordinances, click here to be directed to American Legal Publishing's website. 94.82 FIRE HYDRANTS, WATER MAINS AND WATER
More informationWe have reviewed the proposed concept plans for Beehive Homes and have the following comments:
12800 Arbor Lakes Parkway, P.O. Box 1180, Maple Grove, MN 55311-6180 FIRE-RESCUE DEPARTMENT Fire Operations Fire Prevention 763-494-6300 763-494-6090 763-494-6421 Fax 763-494-6439-Fax August 22, 2018 RE:
More informationORDINANCE NO
ORDINANCE NO. 2016-14 AN ORDINANCE AMENDING THE CODE OF ORDINANCES, CITY OF BOERNE, TEXAS, BY AMENDING CHAPTER 5 - BUILDINGS AND BUILDING REGULATIONS, ARTICLE VIII, LIFE & SAFETY CODE, SECTION 5-236; AND
More informationEXHIBIT A STEAMBOAT SPRINGS FIRE PREVENTION SERVICES ADMINISTRATIVE POLICY & PROCEDURE MANUAL
EXHIBIT A STEAMBOAT SPRINGS FIRE PREVENTION SERVICES ADMINISTRATIVE POLICY & PROCEDURE MANUAL SECTION: 4 POLICY NO.: 1258.1D DATE: September 11, 2006 PAGE: 1 SUBJECT: Fire Apparatus Access Road Standards
More informationICC CODE CORNER 2015 International Fire Code
SECTION 504 ACCESS TO BUILDING OPENINGS AND ROOFS 504.1 Required access. Exterior doors and openings required by this code or the International Building Code shall be maintained readily accessible for
More informationRocky Mountain Fire Protection District 4390 Eldorado Springs Drive Boulder, CO
Rocky Mountain Fire Protection District 4390 Eldorado Springs Drive Boulder, CO 80303 303-494-3735 Contractor s Checklist and Installation Guide TABLE OF CONTENTS Fire Protection Narrative........... 3
More informationFire Sprinkler Submittal Requirements and Acceptance Testing
Lubbock Fire Marshal s Office 1601 Mac Davis Lane Lubbock, Texas 79401 806-775-2646 Fax 806-775-3508 fireprevention@mylubbock.us Fire Sprinkler Submittal Requirements and Acceptance Testing To all Registered
More informationCity of Vista Fire Department
City of Vista Fire Department Development Services Section 600 Eucalyptus Avenue, Vista CA 92084 Guideline: Underground Piping for Private Fire Hydrants & Fire Sprinkler Supply. Updated: January, 2008
More informationLife Safety - Means of Egress/Exits NFPA 101
Life Safety - Means of Egress/Exits NFPA 101 Properly designed exits provide a safe path of escape from a fire or other emergency environment. The means of egress (exits) should be arranged to permit all
More informationFIRE CODE APPLICATION GUIDE FOR DEVELOPMENT IN UNINCORPORATED MULTNOMAH COUNTY
FIRE CODE APPLICATION GUIDE FOR DEVELOPMENT IN UNINCORPORATED MULTNOMAH COUNTY This guide is intended to provide assistance in the application of the fire code in Unincorporated Multnomah County. October
More informationFIRE-FLOW REQUIREMENTS FOR BUILDINGS Based on the 2012 Edition of the International Fire Code
FIRE-FLOW REQUIREMENTS FOR BUILDINGS Based on the 2012 Edition of the International Fire Code One of the basic essentials needed to control and extinguish a structure fire is an adequate water supply.
More informationMCKINNEY FIRE DEPARTMENT FIRE MARSHAL S OFFICE FIRE LANES
MCKINNEY FIRE DEPARTMENT FIRE MARSHAL S OFFICE FIRE LANES This guide is intended to be a resource for when a building, structure, or facility, within the City of McKinney, is required to be provided with
More informationCLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau
CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 Permit Type: 105.7.13 Control Number: A.0 Effective Date: 11/15/11 TITLE:
More informationResidential-based Care Facility R-4 Guideline
Moreno Valley Fire Department Fire Prevention Bureau Residential-based Care Facility R-4 Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: April 7, 2017 Residential-based Care
More informationGLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE
GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE To: From: Subject: Whom It May Concern Carl Ray Austerman, Fire Marshal Contractor s Guide Welcome to the Glendale Fire Department s Contractors Guide. This
More informationEnvironmental Health & Safety
Environmental Health & Safety Oklahoma State University FIRE SPRINKLER SYSTEM STANDARD Environmental Health and Safety University Health Services Suite 002 Stillwater, OK 74078 (405) 744-7241 www.ehs.okstate.edu
More informationDESIGN & CONSTRUCTION GUIDELINES
ADMINISTRATIVE SERVICES 4202 E. FOWLER AVENUE, FPC110 PHONE: (813) 974-2625 FACILITIES PLANNING & CONSTRUCTION TAMPA, FLORIDA 33620-7550 WEBSITE: USF.EDU/FPC DESIGN & CONSTRUCTION GUIDELINES DIVISION 21
More informationVIOLET TOWNSHIP ZONING & BUILDING DEPARTMENT Rustic Drive Pickerington, Ohio (614) Fax (614)
VIOLET TOWNSHIP ZONING & BUILDING DEPARTMENT 12970 Rustic Drive Pickerington, Ohio 43147 (614) 575-5559 Fax (614) 575-5562 To: From: Subject: All Commercial Zoning and Building Permit Applicants Don Day,
More informationOrange Township Fire Department Fire Prevention Bureau
Orange Township Fire Department Fire Prevention Bureau Under Ground Fire Protection Plan Submittal Checklist Project Name: Project Address: Date: Designers Name: Company Name: Phone Number: Email: Fax:
More informationThis guide is intended to provide assistance in the application of the fire code in all areas served by Tualatin Valley Fire & Rescue.
This guide is intended to provide assistance in the application of the fire code in all areas served by Tualatin Valley Fire & Rescue. North Operating Center 11945 SW 70 th Avenue Tigard, OR 97223 Phone:
More informationCubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM
SECTION 21 0000 AUTOMATIC FIRE SPRINKLER SYSTEM PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Codes and Standards: 1. FBC (Florida Building Code 2015) 2. FBC (Florida Fire Code 2015) 3. NFPA #13R (Standard for
More informationConstruction and Development Guide
Construction and Development Guide **Based on the 2014 Indiana Fire Prevention Code and relevant NFPA Codes and Standards ** Copyright 2018 Clay Fire CRRD 1 P a g e Table of Contents Map of Jurisdiction...
More informationVACAVILLE FIRE PROTECTION DISTRICT 420 Vine Street Vacaville, California (707)
VACAVILLE FIRE PROTECTION DISTRICT 420 Vine Street Vacaville, California 95688 (707) 447-2252 Requirements for new construction within the boundaries of the Vacaville Fire Protection District include,
More informationFIRE PLAN CHECK CORRECTION List for Commercial Occupancies
PASS / RESUBMIT Rancho Santa Fe Fire Protection District P.O. Box 410 18027 Calle Ambiente Rancho Santa Fe California 92067-0410 Tel. (858) 756-5971 Fax (858) 756-4799 FIRE PLAN CHECK CORRECTION List for
More informationFIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011
HCFMO Harris County Fire Marshal M.S. Montgomery Fire Marshal FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011 EFFECTIVE JANUARY 1, 2007 These guidelines
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD STANDPIPE SYSTEMS PURPOSE This standard outlines the general requirements for the installation of standpipe systems. CODE REFERENCES
More informationRED BOOK CONTRACTOR S. Fire Department Access and Design Engineering Information
RED CONTRACTOR S BOOK Fire Department Access and Design Engineering Information Orange County Fire Rescue Department An Accredited; Class One Department OFFICE OF THE FIRE MARSHAL David G. Kilbury, Fire
More informationDepartment of Planning & Development Planning Unit
Department of Planning & Development Planning Unit Website: www.cityofmadison.com Madison Municipal Building 215 Martin Luther King, Jr. Boulevard P.O. Box 2985 Madison, Wisconsin 53701-2985 TDD 608 266
More informationOsceola County Department of Fire Rescue and Emergency Medical Services
St. Number Dir Street Name Street Type Inspected Time of Day to be Re-inspected Zip Code Occupancy Type Emergency Contact Phone (Inc. Area Code) Building Owner Building Owner Mailing Address Bldg. Owner
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST FIRE AND LIFE SAFETY SYSTEMS FOR STRUCTURES FIVE OR MORE STORIES IN HEIGHT AND LESS THAN 75 FEET IN HEIGHT FROM THE POINT
More informationFIRE PREVENTION CODE
164.01 Purpose 164.03 Amendments to Fire Prevention Code 164.02 Adoption of Fire Prevention Code 164.04 Board of Appeals 164.01 PURPOSE. The purpose of this chapter is to prescribe regulations governing
More informationFIRE SERVICE FEATURES
CHAPTER 5 FIRE SERVICE FEATURES SECTION 501 GENERAL 501.1 Scope. Fire service features for buildings, structures and premises shall comply with this chapter. 501.2 Permits. A permit shall be required as
More informationCOMMERCIAL SITE PLAN SUMMARY & DEVELOPMENT GUIDE
COMMERCIAL SITE PLAN SUMMARY & DEVELOPMENT GUIDE DEPARTMENT CONTACT: York County Development Coordinating Center (c/o Bea McCarter) 1070 Heckle Boulevard, Suite 107 Rock Hill, South Carolina 29732 Phone
More informationFIRE SERVICE FEATURES
CHAPTER 5 FIRE SERVICE FEATURES SECTION 501 GENERAL 501.1 Scope. Fire service features for buildings, structures and premises shall comply with this chapter. 501.2 Permits. A permit shall be required as
More informationALABAMA. Downloaded
Housekeeping/Laundry/Maintenance ALABAMA Downloaded 01.15.11 (e) Maintain an effective pest control program so that the facility is free of pests and rodents. In the laundry, provision shall be made to
More informationInternational Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures
International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures Please note this is not an all-inclusive list. The type and complexity of your project
More informationFire & Life Safety Supplemental Rules & Regulations for New Construction & Significant Remodels
DEPARTMENT OF PUBLIC SAFETY FIRE MARSHAL S OFFICE 9611 SE 36 TH ST Mercer Island, WA 98040 (206) 236-3515 direct; (206) 236-3622 FAX Rod Mandery, Fire Marshal Updated version: 03-19-2002 Fire & Life Safety
More informationSACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT SERVICES UNIT CONTRATOR INFORMATION PACKET
SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT SERVICES UNIT CONTRATOR INFORMATION PACKET 1 SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT
More informationTo expedite the plan review and inspection processes, please refer to the information below.
Guidelines: The goal of the Denison Fire Department is to assist its customers in understanding our submittal, plan review and inspection process and policies, as they pertain to new construction. Familiarity
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST TENANT IMPROVEMENTS Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved; AC-Approved w/comments;
More information4/13/2015. Everything a firefighter wants to tell a design professional or building code official, in one hour.
Everything a firefighter wants to tell a design professional or building code official, in one hour. 1 2 3 1 4 The job of the fire department is to put the wet stuff on the red stuff. 5 Job #1. of the
More informationSECTION POLICY MANUAL
Menlo Park Fire Protection District Bureau of Fire Prevention and Life Safety 170 Middlefield Rd. Menlo Park, CA 94025 650-688-8425 Bureau of Fire Prevention and Life Safety SECTION 101.6 POLICY MANUAL
More informationFIRE APPARATUS ACCESS
FIRE PROTECTION REQUIREMENTS FIRE APPARATUS ACCESS INCLUDING FIRE LANES, GATES, AND ACCESS ROADS Bureau of Fire Prevention 111 Basin ST / P.O. Box 884 Hebron, Ohio 43025 Telephone: 740-928-4721 Fax: 740-928-2726
More informationFire District Dwelling Construction Requirements
Fire District Dwelling Construction Requirements Includes Sacramento County Fire Marshals Association Standard for Residential Sprinklers City of Rancho Cordova Building & Safety Department 2729 Prospect
More informationTRI-LAKES MONUMENT FIRE PROTECTION DISTRICT
TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT LOCAL AMENDMENTS INTERNATIONAL FIRE CODE 2009 December 5, 2012 1 Chapter 1 Administration Chapter 5 Fire Service Features Chapter 9 Fire Protection Systems Chapter
More informationCity of Los Angeles January FIRE PROTECTION
ENVIRONMENTAL SETTING 2. FIRE PROTECTION Fire Protection Fire prevention, fire suppression, and life safety services are provided throughout the City of Los Angeles by the Los Angeles Fire Department (LAFD),
More informationConsumer Fireworks in Georgia
Consumer Fireworks in Georgia What are consumer fireworks? Most people call them: The Good Stuff An expert explanation: What are NOT consumer fireworks? (a) Model rockets and model rocket engines designed,
More informationOxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)
Oxnard Fire Department 360 W. Second Street Oxnard, CA 93030 (805) 385-7722 Fax (805) 385-8009 FIVE YEAR CERTIFICATION REPORT Service and maintenance report for automatic fire extinguishing systems, including
More informationCommercial Rules and Regulations
Commercial Rules and Regulations Public Works and Community Development Department City of Shenandoah 29955 I 45 North Shenandoah, Texas 77381 281 298 5522 www.shenandoahtx.us Construction Documents Submit
More informationResidential Based Care Facility Guidelines
Moreno Valley Fire Department Fire Prevention Bureau Residential Based Care Facility Guidelines Approved and Authorized By: Randall Metz, Fire Marshal Issued: January 1, 2011 Residential Based Care Facilities
More informationChapter 2: Identification, water and access
Chapter 2: Identification, water and access As you are approaching the occupancy to be inspected, take note of building and fire protection services. Put yourself in the shoes of a first arriving company
More informationSite Development Plan (SDP) Checklist
Development Services Department 100 N. Wilcox Street, Castle Rock CO 80104 303-660-1393 or CRGov.com Site Development Plan (SDP) Checklist A complete Site Development Plan (SDP) submittal will contain
More informationRecommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region
Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region The following sections, paragraphs, and sentences of the 2015 International Existing
More informationPLANNED DEVELOPMENT (MASTER PLAN & UNIT PLAN)
Central Permit Center 555 Santa Clara Street Vallejo CA 94590 Business License Building Fire Prevention Planning Public Works 707.648.4310 707.648.4374 707.648.4565 707.648.4326 707.651.7151 PLANNED DEVELOPMENT
More information3.10 ROW Overlay District
3.10 A. Purpose The purpose of this Overlay District is to regulate items which could be placed or constructed within the Rights-of-way lying wholly or partially within the jurisdictional area of the Town
More informationPLAN REVIEW CHECKLIST
PLAN REVIEW CHECKLIST Date Documents Submitted: Log No.: File No.: Property Information Building Name: Building Address: Owner s Name: Owner s Address: Owner s Phone: Fax: E-mail: System Designer/Contractor
More informationCHAPTER 7 ALTERATIONS LEVEL
CHAPTER 7 ALTERATIONS LEVEL 2 SECTION 701 GENERAL 701.1 Scope. Level 2 alterations as described in Section 404 shall comply with the requirements of this chapter. Exception: Buildings in which the reconfiguration
More informationLarge Family Daycare Guideline
Moreno Valley Fire Department Fire Prevention Bureau Large Family Daycare Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: April 10, 2017 Large Family Daycare Guideline Purpose
More informationEL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD
EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD STANDARD #F-002 EFFECTIVE 05-27-2009 PURPOSE: To define the requirements for a License. To facilitate the quick application and review of new or changed
More informationSITE PLAN REVIEW APPLICATION AND CHECKLIST
SITE PLAN REVIEW APPLICATION AND CHECKLIST PROJECT SUMMARY: Project Name: City/ETA Location: City ETA (Application fee & number of copies needed are based on location) Property Location (Legal Description
More informationHCD DSA OSHPD 1 2 1/AC AC SS SS/CC
CALIFORNIA BUILDING CODE MATRIX ADOPTION TABLE CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency
More informationSecond Revision No. 20-NFPA [ Section No. 1.4 ] Supplemental Information. Submitter Information Verification. Committee Statement
Second Revision No. 20-NFPA 14-2015 [ Section No. 1.4 ] 1.4* Equivalency. Nothing in this standard is intended to prevent the use of systems, methods, or devices of equivalent or superior quality, strength,
More informationGLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE
GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE To: Contractors From: Charles Jenkins, Fire Marshal Subject: Contractor s Guide This guide is provided by the Fire Marshal as a service to the construction
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD
July 2017 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD SPECIAL EVENT PUBLIC ASSEMBLY PURPOSE This standard is applicable to any public event, exhibit space, booth, festival or any other similar
More informationThe Owner will provide the QEI inspection and certification services.
General The Owner will provide the QEI inspection and certification services. Elevators Electric operated traction elevators are preferred; holeless hydraulic oil operation may be considered where use
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS Address: Permit #: Inspector: Date Inspected: Status: Inspector: Date Inspected: Status: A-Approved;
More informationMontgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040
Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040 SPRINKLER SHOP DRAWINGS 2007 NFPA 13 and 2007 NFPA 24 Project: Listed items require sprinkler
More informationCommercial Application/Plan Review Submittal Checklist
Commercial Application/Plan Review Submittal Checklist The following checklist has been compiled to assist in expediting the commercial plan review and permit issuance process. Please take a moment to
More informationPINETOP FIRE DEPARTMENT TIMBER MESA FIRE AND MEDICAL DISTRICT
Amendments for 2015 IFC CHAPTER 1 SCOPE AND ADMINISTRATION Section 101.2.1 Appendices. All appendices to be adopted Section 113.2 Schedule of permit fees. Is AMENDED to read: A fee for each permit shall
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD LICENSED CARE FACILITIES SCOPE: This standard provides requirements for licensed care facilities known as for the Elderly with seven
More informationTo provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.
EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD STANDARD #F-003 EFFECTIVE 06-03-2009 PURPOSE To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified
More informationA. This section includes design and performance information for fire protection and suppression systems.
SECTION 21 00 10: FIRE PROTECTION SYSTEM DESIGN 1. SUMMARY A. This section includes design and performance information for fire protection and suppression systems. 2. GENERAL A. All fire protection materials
More informationSprinkler Permit Applications
REQUIREMENTS FOR NFPA 13 SYSTEM Building Inspections Sprinkler Permit Applications A complete application for a Sprinkler Permit will comply with the requirements of Chapter 8 of NFPA 13. Hydraulic calculations
More informationApplication for Site Plan Review
Application for Site Plan Review City of Pontiac Office of Land Use and Strategic Planning 47450 Woodward Ave, Pontiac, MI 48342 T: 248.758.2800 F: 248.758.2827 Property/Project Address: Sidwell Number:
More informationBusiness Fire Inspection. City of Guadalupe
Business Fire Inspection City of Guadalupe Intent Provide general information on the California Fire Code (CFC) and City of Guadalupe Municipal Code (GMC) requirements. Provide information and the most
More informationGENERAL AREAS OF INSPECTION
This information is intended to assist you in preparation for the annual high-rise inspection. This is not a complete list and the Inspector may identify other conditions or issues in the building that
More informationADA Checklist Transient Lodging, Hotels, Motels, Inns, Boarding Houses, Dormitories and similar facilities
ADA Checklist Transient Lodging,, Motels, Inns, Boarding Houses, Dormitories and similar facilities 205 North 400 West Salt Lake City, Utah 84103 (800) 662 9080 (800) 550 4182 TTY www.disabilitylawcenter.org
More informationFIRE SAFETY REQUIREMENTS FOR PRE RESIDENTIAL BUILDINGS OF THREE OR MORE STORIES (DOROTHY MAE ORDINANCE - NO. 158,963)
INFORMATION BULLETIN / PUBLIC - MECHANICAL CODE REFERENCE NO.: LAMC 91.8604 Effective: 6-20-84 DOCUMENT NO. P/MC 2002-005 Revised: 6-15-00 Previously Issued As: MGD #74 FIRE SAFETY REQUIREMENTS FOR PRE-
More informationConstruction & Development Procedures Guide
Construction & Development Procedures Guide Updated December 2018 TABLE OF CONTENTS Welcome to Front Range Fire Rescue... 3 About This Guide... 3 Getting Started: Planning Approval and Building Permit
More information2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)
CHAPTER 1 SCOPE AND ADMINISTRATION 102.7 Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Chapter 45 47 and such codes and standards shall
More informationCITY OF CHESAPEAKE PUBLIC FACILITIES MANUAL CHAPTER XIII FIRE PROTECTION
CITY OF CHESAPEAKE PUBLIC FACILITIES MANUAL CHAPTER XIII FIRE PROTECTION I. INTRODUCTION A. The Fire Department s role in the development plan review process is to ensure that the effects of an emergency
More informationPlan Review Check List Fire Alarm System
Plan Review Check List Fire Alarm System EXCELSIOR FIRE DISTRICT 241OO SMITHTOWN ROAD SHOREWOOD, MN 55331 Alarm system must be installed according to NFPA 72, 2010 Edition, National Fire Alarm and Signaling
More informationCONTRACT FOR USE OF FIRE PROTECTION SYSTEM
CONTRACT FOR USE OF FIRE PROTECTION SYSTEM THIS AGREEMENT made and entered on this the day of, 20 by and between its successors and assigns, hereinafter referred to as Customer and the Jessamine County
More information