Test Methods for Consideration Into Radio Standard

Size: px
Start display at page:

Download "Test Methods for Consideration Into Radio Standard"

Transcription

1 Test Methods for Consideration Into Radio Standard Jason Allen March 20,2013

2 Test Methods for Consideration Into Radio Standard Reviewed many current NFPA standards including: NFPA Structural and Proximity Clothing and Equipment NFPA Thermal Imaging Cameras NFPA SCBA NFPA PASS

3

4 Pass Methods for Consideration NFPA : Sec. 5 Labeling and User Information Evaluation Sec. 6 Design Evaluation Sec. 7.1 Sound Pressure Levels Sec. 7.1 Signal Frequency Sec. 7.2 Electronic Temperature Stress Sec. 7.3 Corrosion Sec. 7.4 Immersion Leakage Sec. 7.5 Case Integrity Sec. 7.7 Shock Sensitivity Sec Impact - Acceleration Sec Impact - Vibration Sec Impact - Tumble-Vibration Sec. 7.9 Retention System Sec Water Drainage Sec High Temperature Functionality Sec Heat & Flame Sec Product Label Durability Sec Alarm Signal Muffle Test Sec. 7.15, Point to Point RF Sec Loss of Signal Test Sec. 7.17, RF Interference Test

5 Pass Methods for Consideration Sec. 7.2 Electronic Temperature Stress Test 1 Test 2 Test 3 49C for 6 hrs Transitioned to 71C for 4 hrs Repeated 2x. -20C for 4 hrs -20 for 4 hrs Immediate transfer to 71C for 4 hrs Repeated 2x Sec. 7.3 Corrosion 48 hr B117 salt exposure

6 Pass Methods for Consideration Sec. 7.4 Immersion Leakage Procedure 1 177C convective oven 15 min Immediate water immersion for 15 min Repeat 6x Procedure 2 Sec. 7.5 Case Integrity After Procedure 1- specimen dunked w/battery compartment open 200 Kg load on each surface for 1 min

7 Pass Methods for Consideration Sec Impact Acceleration 3 conditions- ambient, -20C, and 71C 8-3 M Drop onto concrete on each face, 1 corner, 1 edge Sec Impact Vibration Stainless steel box, 1 orbit, 250 rpm, 3 hrs Sec Impact - Tumble-Vibration 15 rpm, 3 hrs

8 Pass Methods for Consideration Sec Water Drainage All sound cavities are filled with water and performance is verified Sec High Temperature Functionality Convective oven 500F for 5 min

9 Pass Methods for Consideration Sec Heat & Flame 95C convective Oven for 15 min 10 sec flame exposure ave flame temp 950C Sec Product Label Durability Visual inspection post temperature stress tests Sec Alarm Signal Muffle Test Sound is evaluated w/test subject wearing bunker gear in multiple orientations

10 Additional Methods for Consideration Durability Test- NFPA C for 6 hrs, Raised to 60C for 4 hrs, Lowered to 49C for 4 hrs, Repeated 2x Raised to 60C for 4 hrs, Immediate dunk 1.0M water for 30 min Removed, dried, -20C for 4 hrs Immediate dunk for 30 min Tumbled 30 min at 15 rpm

11 Additional Methods for Consideration RF Evaluation- Post exposure Pass/Fail Cable Pull-out- NFPA lbf in axial direction on all external wires Fabric component Heat - NFPA 1971, C for 5 min Fabric Flame - NFPA 1971, 1981 Burner Edge flame EMC/EMI- NFPA 1801 IEC Intrinsic Safety- NFPA 1981, 1982, 1801 ANSI UL 913 Dust/dirt precondition? IP 6X?- IEC Minimum Battery Life- NFPA 1981 Usability/dexterity style evaluation?

12 Test Order Specimens 1 3 Specimens 4 6 Specimens 7 9 Possible Test Matrix for Radios Specimens Specimens Specimens Specimens Material Testing 1 Radio Specific Tests 2 Case Integrity Specimens Heat and Flame Test Specimen 1 3 Cable Pullout Corrosion Test Test Specimens 7 9 Specimens 4 6 Impact Acceleration Test Ambient Specimen 4 Impact Acceleration Test Cold Specimen 5 Water Drainage Specimens 7-9 Product Label Durability Test Specimens 7 9 Heat Test Specimen RF type test Product Label Durability Test Specimens Electronic Temperature Stress Specimens Vibration Test Specimen RF type test Durability Test Specimens Immersion Leakage Specimens Fabric Heat RF type test RF type test Fabric Flame 4 RF type test Impact Acceleration Test Elevated Temperature Specimen 6 RF type test 5 RF type test

Update and Overview on the NFPA Requirements and Testing for Electronic Safety Equipment

Update and Overview on the NFPA Requirements and Testing for Electronic Safety Equipment Update and Overview on the NFPA Requirements and Testing for Electronic Safety Equipment Bruce H. Varner. Chair NFPA Technical Committee on Electronic Safety Equipment Fire Chief (Retired) Santa Rosa,

More information

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector PRODUCT SPECIFICATION 108-115057 29OCT13 Rev. A1 0.5mm Fine Stacking Hermaphroditic Type BTB Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for 0.5mm

More information

NFPA Electronic Safety Equipment Standards What s happening now!

NFPA Electronic Safety Equipment Standards What s happening now! Precision Indoor Personnel Location and Tracking for Emergency Responders Technology Workshop August 4-5, 2008 Worcester Polytechnic Institute, Worcester, MA NFPA Electronic Safety Equipment Standards

More information

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming) Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming) 02Oct08 Rev A 1. SCOPE 1.1. Content This specification, based on IEC 61753-1 Edition 1.0 tests for Category E (Extreme Environment),

More information

Wire Wound SMD Power Inductors / ENRS Series

Wire Wound SMD Power Inductors / ENRS Series .Feature: 1. Magnetic-resin shielded construction reduces buzz noise to ultra-low levels. 2. Metallization on ferrite core results in exce llent shock and damage-free durability. 3. Closed magnetic circuit

More information

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616 TO WHOM IT MAY CONCERN Product Test report Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616 Product name: BOSCH FLEXIDOME IP outdoor 4000 HD/IR BOSCH FLEXIDOME IP outdoor

More information

INSTRUCTION MANUAL. Full Size Gas Convection Oven

INSTRUCTION MANUAL. Full Size Gas Convection Oven INSTRUCTION MANUAL Full Size Gas Convection Oven This manual contains important information regarding your unit. Please read this manual thoroughly prior to equipment set-up, operation and maintenance.

More information

SolderSleeve Insulated Electrical Termination Devices

SolderSleeve Insulated Electrical Termination Devices Tyco Electronics Corporation 300 Constitutional Drive Menlo Park, CA 94025 USA Specification This Issue: Date: Replaces: RT-1404 ISSUE 9 April 20, 2000 ISSUE 8 1.0 INTRODUCTION SolderSleeve Insulated Electrical

More information

Plug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165

Plug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165 PRODUCT SPECIFICATION Sep 22, 29 Rev. B CONNECTOR, SINGLE CAVITY, AEROSPACE, PANEL MOUNT, FLOATING, EN416 1 - SCOPE 1.1. Content This document covers the performances, tests, and quality requirements of

More information

Select the proper RFID Tag for Harsh Environments. Richard Aufreiter, PM, HID Global

Select the proper RFID Tag for Harsh Environments. Richard Aufreiter, PM, HID Global Select the proper RFID Tag for Harsh Environments Richard Aufreiter, PM, HID Global An ASSA ABLOY Company The global leader in door opening solutions Operations in more than 70 countries $ 7.5 billion

More information

UN Test Report - ASM P/N 45N1010 (Nom. 94Wh, 11.1V)-

UN Test Report - ASM P/N 45N1010 (Nom. 94Wh, 11.1V)- 문서번호 Prepared Reviewed Approved QAEEF02111013PKASMP/N45N1010 김홍일남익현이문규남대호최운기정준용 UN Test Report ASM P/N 45N1010 (Nom. 94Wh, 11.1V) 목차 1. UN Transportation Regulation Test 2. Test Procedure 3. Test 4. Sample

More information

UN Test Report - ASM P/N 45N1028 (Nom. 94Wh, 11.1V)-

UN Test Report - ASM P/N 45N1028 (Nom. 94Wh, 11.1V)- 문서번호 Prepared Reviewed Approved QAEEF02111013PKASMP/N45N1028 김홍일남익현이문규남대호최운기정준용 UN Test Report ASM P/N 45N1028 (Nom. 94Wh, 11.1V) 목차 1. UN Transportation Regulation Test 2. Test Procedure 3. Test 4. Sample

More information

DYNAMICS WHILE DRILLING DWD SOLUTIONS LODESTARINT.COM

DYNAMICS WHILE DRILLING DWD SOLUTIONS LODESTARINT.COM DYNAMICS WHILE DRILLING DYNAMICS WHILE DRILLING The Lodestar suite of dynamics while drilling (DWD) tools allows customers to obtain the downhole data that enables them to create the most efficient and

More information

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT) Product 108-5390 Specification 31 OCT 17 Rev.F1 Free Height 0.8 mm Pitch Board-to-Board Connector (SMT) 1. SCOPE 1.1. Contents This specification covers the requirements for product performance, test methods

More information

Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor

Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor www.astm.org ASTM D1230 Flammability of Apparel Textiles Scope: This test method covers the evaluation of the flammability

More information

Digital Thermometer with Ice Alert and Clock

Digital Thermometer with Ice Alert and Clock Digital Thermometer with Ice Alert and Clock Model: RAR381 USER MANUAL Specifications... 8 About Oregon Scientific... 8 EU-Declaration of Conformity... 9 FCC Statement... 9 Declaration of Conformity...

More information

Two Circuit Heavy Duty Burner Connector

Two Circuit Heavy Duty Burner Connector Product 108-1056 11 Oct.16 Rev B Specification EC 0990-0059-05 Two Circuit Heavy Duty Burner Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the

More information

TTM-01: ebm-papst fans for outdoor applications water and humidity protection

TTM-01: ebm-papst fans for outdoor applications water and humidity protection TTM-01: ebm-papst fans for outdoor applications water and humidity protection April 2015 1 ebm-papst protection classes We often get asked for IP ratings on fans as these have been specified. However,

More information

Dome Fiber Optic Closure SC-221

Dome Fiber Optic Closure SC-221 Dome Fiber Optic Closure SC-221 General Information SC-221 fiber optic closure protects the fiber optic splices from harsh external environment conditions. It is designed for many network segments and

More information

Product Tests Report

Product Tests Report TO WHOM IT MAY CONCERN Page: 1 of 5 Product name: Model number and description: MIC IP starlight 7000i Product Tests Report MIC-7502-Z30B, PTZ camera 2MP HDR 30x IP68 IK10, black MIC-7502-Z30W, PTZ camera

More information

Public Input No. 99-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

Public Input No. 99-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input 1 of 218 5/20/2016 12:24 PM Public Input No. 99-NFPA 1982-2016 [ Section No. 1.1.3 ] 1.1.3 This standard shall not specify requirements for any manufactured to previous editions of this standard To enable

More information

Specification Status: Released

Specification Status: Released PAGE NO.: 1 OF 8 Specification Status: Released Not to be used for new designs. For new design please contact Tyco Electronics Sales BENEFITS Board space savings Help protect sensitive electronic circuits

More information

AIRCRAFT RESCUE AND FIREFIGHTING

AIRCRAFT RESCUE AND FIREFIGHTING AIRCRAFT RESCUE AND FIREFIGHTING ICAO/FAA Regional Workshop for Aerodrome Certification Safety Inspectors November 6-8, 2012 ARFF 1 INSPECTING AIRCRAFT RESCUE AND FIREFIGHTING (ARFF) Tools, records, knowledge

More information

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems Qualification Test Report 501-93032 14/April/2011 Rev A AMP-TWIST Series Jacks for Class EA systems 1. INTRODUCTION 1.1 Purpose Qualification testing on AMP-TWIST* Series Jacks for Class E A Systems, to

More information

Synco living. Train the Trainer. Mounting Safety Devices. August 2007 Page 1/11 Train the Trainer - August 2007

Synco living. Train the Trainer. Mounting Safety Devices. August 2007 Page 1/11 Train the Trainer - August 2007 Synco living Train the Trainer Mounting Safety Devices August 2007 Page 1/11 Train the Trainer - August 2007 Mounting the Door / window contact AP260 The door / window contact is supplied complete with

More information

DETECT-A-FIRE Heat Detectors

DETECT-A-FIRE Heat Detectors DETECT-A-FIRE Heat Detectors DETECT-A-FIRE thermal detectors are detection and release devices used for fire detection systems to activate alarms and actuate extinguishing systems. This rate compensated

More information

Safe Operation Manual. Honeywell IQ Force Gas Detector

Safe Operation Manual. Honeywell IQ Force Gas Detector Safe Operation Manual Honeywell IQ Force Gas Detector Honeywell Analytics 800-663-4164 403-248-9226 Fax 403-575-3708 03JUN2012 P/N 50105843-047 Version 01 http://www.honeywell.com HONEYWELL IQ Force PERSONAL

More information

JUL 18 Rev A1

JUL 18 Rev A1 Qualification Test Report 501-166004 30 JUL 18 Rev A1 Mini USB-B Header, H-Type SMT 1. INTRODUCTION 1.1. Purpose Testing was performed on the Mini USB-B Header, H-Type SMT to determine if it meets the

More information

Installation Instructions Lithonia Lighting Clean Room Troffer. Grid & Sheet Rock Installation, Maintenance

Installation Instructions Lithonia Lighting Clean Room Troffer. Grid & Sheet Rock Installation, Maintenance Installation Instructions Clean Room Troffer Grid & Sheet Rock Installation, Maintenance Revision 00 I-SRTL Revision Date 8/14/2017 LED IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS!

More information

Pyroelectric Infrared Sensors

Pyroelectric Infrared Sensors Pyroelectric Infrared Sensors Cat.No.S21E-7 for EU RoHS Compliant All the products on this catalog are complied with EU RoHS. EU RoHS is "the European Directive 2002/95/EC on the Restriction of the Use

More information

INSTRUCTION MANUAL WT 498S Radio Controlled Alarm Clock with Temperature and Calendar

INSTRUCTION MANUAL WT 498S Radio Controlled Alarm Clock with Temperature and Calendar INSTRUCTION MANUAL WT 498S Radio Controlled Alarm Clock with Temperature and Calendar EN 1 INSTALLATION For best reception of radio controlled signal, keep your clock close to a window and away from metal

More information

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y LS BARGE PUMP. Vertical high-flow pump

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y LS BARGE PUMP. Vertical high-flow pump N N O V A T I O N E F F I C I E N C Y Q U A L I T Y LS BARGE PUMP LS BARGE For more than 60 years the name Ruhrpumpen has been synonymous worldwide with innovation and reliability for pumping technology

More information

MLLG-DE-LED-CHAN Installation Guide IMPORTANT SAFETY INSTRUCTIONS

MLLG-DE-LED-CHAN Installation Guide IMPORTANT SAFETY INSTRUCTIONS MLLG-DE-LED-CHAN Installation Guide IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards

More information

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models)

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models) 4-1280 Application Engineering Bulletin AE-1280R4 Revised April, 1995 APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models) Introduction The Compliant Scroll Compressor has been

More information

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616 TO WHOM IT MAY CONCERN Product Test report Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616 Product name: BOSCH FLEXIDOME IP indoor 4000 HD/IR BOSCH FLEXIDOME IP indoor

More information

Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services

Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services www.intertek.com/lighting 1 Identifying Product Safety Requirements for Your Target Markets

More information

Life Changing, Life Saving. The Vibby. User and Installation Guide

Life Changing, Life Saving. The Vibby. User and Installation Guide Life Changing, Life Saving The Vibby User and Installation Guide Contents Introduction Getting started Alarm modes Types of falls Simulating a fall Automatic alarm cancellation Manual alarm cancellation

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-32798-9 SOUTH AFRICAN NATIONAL STANDARD Gas measuring equipment primarily for use in mines Part 5: Fire detectors WARNING This standard references other documents normatively. Published

More information

Digital Thermometer with Ice Alert and Radio-Controlled Clock. Model: RMR382 USER MANUAL CONTENTS

Digital Thermometer with Ice Alert and Radio-Controlled Clock. Model: RMR382 USER MANUAL CONTENTS Digital Thermometer with Ice Alert and Radio-Controlled Clock CONTENTS Model: RMR382 USER MANUAL Ice Warning... 7 Hi / Lo Temperature Alarm... 7 Reset... 8 Precautions... 8 Specifications... 8 About Oregon

More information

Digital Thermometer with Ice Alert and Radio-Controlled Clock Model: RMR682

Digital Thermometer with Ice Alert and Radio-Controlled Clock Model: RMR682 Digital Thermometer with Ice Alert and Radio-Controlled Clock Model: RMR682 CONTENTS USER MANUAL Ice Warning... 8 Hi / Lo Temperature Alarm... 8 Reset... 8 Precautions... 8 Specifications... 9 About Oregon

More information

Webinar November 12, 2014

Webinar November 12, 2014 Webinar November 12, 2014 Dennis L. Mater dennis.l.mater@dupont.com FR Apparel Sales Technical Leader North America Webinar Overview Introduction Hazard Risk Types Contrast Short Duration Fire and Arc

More information

Pyroelectric Infrared Sensors

Pyroelectric Infrared Sensors Pyroelectric Infrared Sensors Cat.No.S1E-8 for EU RoHS Compliant All the products on this catalog are complied with EU RoHS. EU RoHS is "the European Directive 011/65/EU on the Restriction of the Use of

More information

DHL-LP-LED Low Profile LED Linear High/Low Bay

DHL-LP-LED Low Profile LED Linear High/Low Bay IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions

More information

and Product Data VTP Selection Guide

and Product Data VTP Selection Guide Selection Guide and Product Data This section has two parts: A Selection Guide that walks you through the process of selecting the correct VTP device for a circuit. Product Data that outlines electrical

More information

Jan05 Rev A EC

Jan05 Rev A EC Product Specification Two Circuit Heavy Duty Burner Connector 108-1056 12Jan05 Rev A EC 0990-0059-05 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the

More information

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS LED IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage

More information

Inspection Points Trailers & Fifth Wheels

Inspection Points Trailers & Fifth Wheels Inspection Points Trailers & Fifth Wheels We at RVIS, LLC appreciate your business and look forward to providing you with the professional RV inspection you deserve. So that we may provide you with a thorough

More information

Service manual. Type: TD25. Contents

Service manual. Type: TD25. Contents Service manual Type: TD25 Contents Introduction...3 Type overview...4 Programme...5 Indication of programme sequence...5 Options and settings...6 Variant settings...8 Test programme...9 Troubleshooting...11

More information

Following this guideline enables proper treatment of the relays during the critical phase in the relay life.

Following this guideline enables proper treatment of the relays during the critical phase in the relay life. Electromechanical relays are one of the most robust and most reliable electronic components. In order to achieve and guarantee the excellent performance of AXICOM relays, some precautions must be taken

More information

ICC CODE CORNER 2015 International Fire Code

ICC CODE CORNER 2015 International Fire Code SECTION 609 COMMERCIAL KITCHEN HOODS [M] 609.1 General. Commercial kitchen exhaust hoods shall comply with the requirements of the International Mechanical Code. [M] 609.2 Where required. A Type I hood

More information

JONES Membrane Vent is designed to protect enclosures and devices from particles, water, oil, and other

JONES Membrane Vent is designed to protect enclosures and devices from particles, water, oil, and other Membrane Vent Product Description JONES Membrane Vent is designed to protect enclosures and devices from particles, water, oil, and other liquids without negatively affecting their operation. It is comprised

More information

Installation/Instruction Manual

Installation/Instruction Manual 1510876HC8902 Pressurized ventilators (for device cooling) Model Blade diameter (cm) Indoor or outdoor EF-20UYS-UL EF-25UAS-UL EF-30UBS-UL 20 25 30 Indoor Installation/Instruction Manual For customers

More information

Jun08 Rev A

Jun08 Rev A Product Specification Terminal Block Crimp Snap Plug Assembly 108-2319 09Jun08 Rev A 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the Tyco Electronics

More information

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions IFT-RC150 IntelliFire Touch Remote Control Installation Instructions Leave this manual with party responsible for use and operation. 1. Introduction The IFT-RC150 is a wall mounted device that is designed

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Unit 8 Contact: Mrs G Baker Woodfieldside Business Park Tel: +44 (0)1495 229219 Pontllanfraith Fax: +44 (0)1495 228331 Blackwood E-Mail: ginnie.baker@kiwa.co.uk

More information

EN Oregon Scientific Radio-Controlled Projection Clock (RM816P / RM816PU / RM816PUL) User Manual

EN Oregon Scientific Radio-Controlled Projection Clock (RM816P / RM816PU / RM816PUL) User Manual Oregon Scientific Radio-Controlled Projection Clock (RM816P / RM816PU / RM816PUL) User Manual TABLE OF CONTENTS Introduction... 1 Key Features... 1 Front View... 1 Back View... 1 LCD Display Symbols...

More information

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) 501-586 26Feb09 Rev F 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LightCrimp*

More information

SP METHOD 5320 Issue No: Test method for fire detection systems installed in engine compartments of heavy vehicles

SP METHOD 5320 Issue No: Test method for fire detection systems installed in engine compartments of heavy vehicles SP METHOD 5320 Test method for fire detection systems installed in engine compartments of heavy vehicles Page 1(17) Copyright This test method is copyrighted by SP. Neither a printed nor electronic copy

More information

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...

More information

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS LED IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage

More information

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

Chapter 17 Test. Directions: Write the correct letter on the blank before each question. Chapter 17 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Describe initial factors to consider when suppressing structure fires. 1. Which strategy

More information

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External

More information

Apr06 Rev A

Apr06 Rev A Qualification Test Report LC, Multimode, One-Piece Housing, Fiber Optic Connector 501-628 03Apr06 Rev A 1. INTRODUCTION 1.1. Purpose 1.2. Scope Testing was performed on Tyco Electronics LC multimode, one-piece

More information

Weather Station Advanced Model: BAR628HG / BAR628HGU User Manual

Weather Station Advanced Model: BAR628HG / BAR628HGU User Manual Weather Station Advanced Model: BAR68HG / BAR68HGU User Manual CONTENTS Contents... Introduction... Product Overview... Front View... Back View... LCD Display... Remote Sensor (THGRNX)... Getting Started...

More information

UN Test Report - ASM P/N 42T4882 (Nom. 63Wh, 11.1V)-

UN Test Report - ASM P/N 42T4882 (Nom. 63Wh, 11.1V)- 문서번호 Prepared Reviewed Approved QAEEF02101122PKASM P/N 42T4882 김홍일안경봉남익현남대호최운기정준용 UN Test Report ASM P/N 42T4882 (Nom. 63Wh, 11.1V) 목차 1. UN Transportation Regulation Test 2. Test Procedure 3. Test 4.

More information

UN Test Report - ASM P/N 42T4946, ASM P/N 42T4956 (Nom. 32Wh, 11.1V)-

UN Test Report - ASM P/N 42T4946, ASM P/N 42T4956 (Nom. 32Wh, 11.1V)- 문서번호 Prepared Reviewed Approved QAEEF02110122PKASM P/N 42T4946, 42T4956 김홍일안경봉남익현남대호최운기정준용 UN Test Report ASM P/N 42T4946, ASM P/N 42T4956 (Nom. 32Wh, 11.1V) 목차 1. UN Transportation Regulation Test 2.

More information

Quick Touch Pendant User Guide

Quick Touch Pendant User Guide Quick Touch Pendant User Guide 2018 RF Technologies, Inc. All specifications subject to change without notice. All Rights Reserved. No Part of this work may be reproduced or copied in any form or by any

More information

CONVECTION MICROWAVE OVEN FOUR MICRO-ONDES À CONVECTION

CONVECTION MICROWAVE OVEN FOUR MICRO-ONDES À CONVECTION CONVECTION MICROWAVE OVEN CMO-24SS models FOUR MICRO-ONDES À CONVECTION Modèles CMO-24SS INSTALLATION GUIDE / USER GUIDE GUIDE D INSTALLATION / GUIDE D UTILISATION US CA IMPORTANT SAFETY INSTRUCTIONS When

More information

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet The following information must be fully completed and forwarded to your local Liebert sales office to establish your equipment warranty. Installer Address Owner Address Owner e-mail address Installation

More information

Atomic Projection Alarm

Atomic Projection Alarm Model: 616-143 Quick Setup Guide DC: 061014 Atomic Projection Alarm Snooze/Backlight Projection Lens Projection Arm Rotation (Front and Back) FRONT VIEW Buttons Projection Focus BACK VIEW AC Power Jack

More information

Hydrogen Sensor Testing and Certification Underwriters Laboratories Inc.

Hydrogen Sensor Testing and Certification Underwriters Laboratories Inc. Hydrogen Sensor Testing and Certification 2011 Underwriters Laboratories Inc. Underwriters Laboratories Inc. Working for a safer world since 1894 2011 Underwriters Laboratories Inc. Overview Introduction

More information

IEC Type Test Report Report No. EU1515-H-00.3 Type PVI-LP Polymer Arrester 10,000 A Line Discharge Class 2

IEC Type Test Report Report No. EU1515-H-00.3 Type PVI-LP Polymer Arrester 10,000 A Line Discharge Class 2 IEC Type Test Report Report No. EU1515-H-00.3 Type PVI-LP Polymer Arrester 10,000 A Line Discharge Class 2 This report records the results of this type test made on 10 ka Class 2 arresters rated 3 thru

More information

DNVGL-CP-0398 Edition December 2015

DNVGL-CP-0398 Edition December 2015 CLASS PROGRAMME Type approval DNVGL-CP-0398 Edition December 2015 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

RF Projection Clock Model: RM939P POLERMO Projection Clock Model: RM939PA

RF Projection Clock Model: RM939P POLERMO Projection Clock Model: RM939PA RF Projection Clock Model: RM939P POLERMO Projection Clock Model: RM939PA USER MANUAL CONTENTS Introduction... 1 Overview... 1 Clock Front View... 1 Clock Back View... 2 LCD Display... 2 Getting Started...

More information

Model: WS-9133U-IT Quick Setup Guide DC: WIRELESS FORECAST STATION

Model: WS-9133U-IT Quick Setup Guide DC: WIRELESS FORECAST STATION Model: WS-9133U-IT Quick Setup Guide DC: 041916 WIRELESS FORECAST STATION Time 12/24hr + Alarm Indoor Temp. ºF/ºC Forecast Icon + Tendency Arrow Outdoor Temp. ºF/ºC Wall Hanging Hole TX37U-IT Temperature

More information

E-20 COMPARTMENT FLOODING WATER LEVEL DETECTORS (INCLUDING SENSORS)

E-20 COMPARTMENT FLOODING WATER LEVEL DETECTORS (INCLUDING SENSORS) Guideline No.: E-20(201510) E-20 COMPARTMENT FLOODING WATER LEVEL DETECTORS (INCLUDING Issued date: October 20,2015 China Classification Society Foreword: This Guideline is a part of CCS Rules, which contains

More information

General safety precautions English

General safety precautions English English A min (m 2 ) 550 530 540 510 520 490 500 470 480 450 460 430 440 410 420 390 400 370 380 350 360 330 340 310 320 290 300 270 280 250 260 230 240 210 220 190 200 170 180 150 160 130 140 110 120

More information

General safety precautions English

General safety precautions English English A min (m 2 ) 550 530 540 510 520 490 500 470 480 450 460 430 440 410 420 390 400 370 380 350 360 330 340 310 320 290 300 270 280 250 260 230 240 210 220 190 200 170 180 150 160 130 140 110 120

More information

A New Standard of Excellence

A New Standard of Excellence A New Standard of Excellence PREVENTION IS SO EASY... LIVING THROUGH A DISASTER IS NOT The reliable identification of low combustion oxygen in a fired heater or boiler has always been critical to the effectiveness

More information

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products 1.0 Scope This specification covers the design, performance and qualification requirements for Raychem Side Entry Insulation Damage Repair Sleeve. 1.1 Description. Raychem SEIDRS covered by this specification

More information

Installation Instructions

Installation Instructions Installation Instructions Vent/Exhaust Pipe External Trap Kit KGAET0101ETK Table 1 Kit Contents PART DESCRIPTION PART NO. QUANTITY Condensate Trap 308589-402 1 Tee-Vent Fitting (2-in. PVC) 321496-301 1

More information

Reset system Safety and care Warnings Additional resources Troubleshooting Specifications... 16

Reset system Safety and care Warnings Additional resources Troubleshooting Specifications... 16 TABLE OF CONTENTS About this guide... 2 Product overview... 3 Getting started... 7 Batteries... 7 AC power adapter... 7 Change settings... 7 Clock... 8 Alarm... 10 Temperature... 11 Backlight... 11 Projector...

More information

INSTALLATION INSTRUCTIONS WARNINGS AND INSTRUCTIONS FOR LUMINAIRES

INSTALLATION INSTRUCTIONS WARNINGS AND INSTRUCTIONS FOR LUMINAIRES INSTALLATION INSTRUCTIONS WARNINGS AND INSTRUCTIONS FOR LUMINAIRES Philips Lighting North America Philips Lighting Canada Ltd. Corporation 281 Hillmount Road, 200 Franklin Square Drive, Markham ON, Canada

More information

CERTIFICATION BULLETIN

CERTIFICATION BULLETIN File: ULC-S527-11 ULC-G5.2 June 1, 2012 CERTIFICATION BULLETIN 2012-04 Effective Date Announcement CAN/ULC-S527-11, 3 rd Edition of the Standard for Control Unit for Fire Alarm Systems To: Subscribers

More information

SLOT PSW LED IMPORTANT SAFETY INSTRUCTIONS

SLOT PSW LED IMPORTANT SAFETY INSTRUCTIONS SLOT PSW LED IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property

More information

Instrument Standards Used in Security Applications Presented by: Leticia Pibida, Ph.D.

Instrument Standards Used in Security Applications Presented by: Leticia Pibida, Ph.D. Instrument Standards Used in Security Applications Presented by: Leticia Pibida, Ph.D. leticia.pibida@nist.gov Summary of NIST Efforts in DHS/DNDO Standard development Work Consensus standards ANSI/ IEEE,

More information

EU RO Mutual Recognition Technical Requirements

EU RO Mutual Recognition Technical Requirements 1. PRODUCT DESCRIPTION... 1 2. DESIGN EVALUATION... 2 3. PRODUCTION REQUIREMENTS... 4 4. MARKING REQUIREMENTS... 4 5. TYPE APPROVAL CERTIFICATE CONTENT... 5 6. APPROVAL DATE AND REVISION NUMBER... 5 7.

More information

INTRODUCTION CONTENTS

INTRODUCTION CONTENTS INTRODUCTION CONTENTS Weather Station Model:BAR626 / BAR626U User Manual Contents... Introduction... 2 Product Overview... 2 Front View... 2 Back View... 2 LCD Display... 3 Remote Sensor (THN22N)... 3

More information

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations KLC 10 Technical information UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations Description The KLC 10 is a compact UV flame detector, which has been developed

More information

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series FT702LT Turbine control wind sensor......gives durability a new meaning FT702LT series Proven High Availability The FT702LT ultrasonic anemometer is the result of FT Technologies 10 years of experience

More information

Dimension drawing. Main feature. Dimension (H x W x D) Cooling capacity *Note. Standalone temperature control. Rated voltage.

Dimension drawing. Main feature. Dimension (H x W x D) Cooling capacity *Note. Standalone temperature control. Rated voltage. External door mount HEX100PC series Dimension drawing Features Main feature Unit Specification IP55 waterproof at external side "One touch" dry run test and dust cleaning Dimension (H x W x D) mm (inch)

More information

R-S38FPH R-S38FPHL

R-S38FPH R-S38FPHL R-S38FPH R-S38FPHL 8 8 9 17 10 12 12 13 13 13 16 16 17 17 Children should be supervised to ensure that they do not play with the appliance or get in. Children getting inside may not be able to get out.

More information

HEX050QA Heat Exchanger Instruction Manual

HEX050QA Heat Exchanger Instruction Manual HEX050QA Heat Exchanger Instruction Manual USA 46101 Fremont Blvd, Fremont, CA 94538, U.S.A. TEL : 1-510-668-5100 FAX : 1-510-668-0680 Cabinet-Thermal-Solutions@deltaww.com Taiwan Delta Electronics, Inc.

More information

Components of the device. Appearance of the device. ihealth thermometer User s manual LED screen. Manufacturer info. LED screen.

Components of the device. Appearance of the device. ihealth thermometer User s manual LED screen. Manufacturer info. LED screen. Components of the device The external body of the thermometer is made of plastic. The device is equipped with an infrared temperature sensor, MCU, electro-acoustic components, batteries, LED-screen, battery

More information

Ultra-high performance heat insulation transportation box Transportation Package System for Temperature Sensitive Medical Substances

Ultra-high performance heat insulation transportation box Transportation Package System for Temperature Sensitive Medical Substances Ultra-high performance heat insulation transportation box Transportation Package System for Temperature Sensitive Medical Substances Sugiyama-Gen Co.,Ltd. Establishment : 1932 Scope of business : Medical

More information

CERTIFICATION BULLETIN

CERTIFICATION BULLETIN File: ULC Subject C100 ULC-G.5.2 CCF7 S500F/SC2 October 28, 2014 CERTIFICATION BULLETIN 2014-07 Second Edition ULC/ORD-C100-13 Smoke Control System Equipment To: Members of the ULC Advisory Committee Members

More information

TRX SENTINEL. Introduction. Conclusion

TRX SENTINEL. Introduction. Conclusion TRX SENTINEL Introduction Technical Discussion Conclusion TRX Team We are committed to building a reasonably price tracking system for firefighters! About TRX Systems, Inc TRX s mission is to provide first

More information

Above Ground Fuel Tank Requirements

Above Ground Fuel Tank Requirements FIRE DEPARTMENT in cooperation with Above Ground Fuel Tank Requirements The purpose of this document is to provide information about general Fire Code requirements for above ground storage within the unincorporated

More information

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord 100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord Part #: EPL-PM-100LED-UVA-150-EPP Page: 1 The EPL-PM-100LED-UVA-150-EPP from Larson Electronics is an Explosion

More information

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS 48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,

More information