1 Full Service Central Station Fire Alarm Listing Evaluation Listing Evaluation A UL Listing project includes: 1. Evaluating the central station facility for compliance with UL 827, Central-Station Alarm Services 2. Analyzing the ability of central station staff to receive, process, and record signals received from selected systems in accordance with NFPA 72, The National Fire Alarm & Signaling Code. 3. Evaluating the actions of runners responding to simulated alarm conditions 4. Examining 3 installations for compliance with NFPA Evaluating your company s ability to service and maintain alarm systems in accordance with NFPA 72 Standards UL Standards are available from COMM 2000, at or NFPA 72 may be purchased from the National Fire Protection Association at Evaluation Details In general, our Listing evaluation will consist of evaluating the installation for compliance with a referenced edition of the NFPA 72, reviewing the system documentation, observing technicians performing periodic testing and inspection of the system, evaluating your company s ability to service & maintain the system and evaluating the ability of the central station staff to process signals. Central Station Facility Please complete a Fire Alarm Central Station Facility pre-evaluation data sheet and return it with the Listing Project quote acceptance. On the day of the central station facility evaluation, please have a technician available who has knowledge of the receivers, automation systems, your network, and all standby power systems. Service Test - An important part of the evaluation is to determine if your personnel are handling alarms in accordance with UL 827 & NFPA 72. During UL staff visits, a service test may be conducted (in coordination with the local Fire Service) by causing an alarm condition at one of the protected properties submitted for examination, witnessing runner arrival, and examining resultant Central Station records. Documentation & Records Review NFPA 72 calls for specific documentation of every Fire Alarm System. During the evaluation, we will examine the following documents for each system to be examined: 1. Fire Alarm System Record of Completion
2 2. As-Built (Record) Drawings 3. Operational Manuals 4. Manufacturer s Testing and Maintenance Instructions/Procedures (may be in Operations Manuals) 5. Battery Calculations 6. Copy of Forms Used to Record Periodic Test and Inspection 7. A completed Acceptance Test record, performed by the Alarm Service Company 8. Required Contracts The Records Description Sheet (ensuing pages) describes the documents further Protected Property Evaluations In order to evaluate compliance with NFPA 72, we will examine 3 alarm systems installed and operated in accordance with NFPA 72. The fire alarm installations may be a mixture of sprinkler water flow supervision, manual pull box or automatic fire detection service. It will be necessary to review an example of each type of service in at least one of the properties. We encourage a phone conversation with UL staff during evaluation set up to clarify and agree on details. None of these systems are required to be certificated after your listing has been established. However, if a Certificate is to be issued, any noncompliance noted during our evaluation must be corrected prior to issuance of the Certificate. Please complete pre-evaluation data sheets describing the elements of protection at the sample installation sites. Data sheets must be submitted when the Listing Project quote is accepted. 1 data sheet package and 1 Confirmation checklist should be completed for each of the 3 systems required for evaluation. The UL Listing evaluation will be based upon the information entered on the data sheets. Accurate information will significant expedite and simplify your evaluation. It is particularly important to identify the edition of NFPA 72 used in the system design & installation. Protected Property Evaluation Visits On the day of the site evaluations, please have available: A qualified technician who is familiar with the protected properties and provided with any equipment necessary to test the devices and components used in the systems All equipment manuals and instructions Specimen documents used in conjunction with service and maintenance of alarm systems (job tickets, records of completion, etc) If you have any questions, please contact UL Customer Service at , ext 40227
3 CENTRAL STATION FIRE ALARM (PROTECTIVE SIGNALING) SERVICE MONITORING STATION PRE-EVALUATION DATA SHEETS Completed forms must be returned to UL prior to the Evaluation Service Center Number: Central Station Co. Name: Service Center Address: Name of Contact: Phone Number: Address:
4 RUNNER INFORMATION Number of Runners per Shift: Qty. in Station #1 Location of Runner (Circle applicable and describe below) Central Station Runner Station Vehicle Other COMMUNICATION MEANS Communication Between the Serving Central Station and the Runner(s): (Note: The communication means must be two-way) Type Test Schedule (1) (2) (3) Location of Test log:
5 **** CENTRAL STATION BUILDING DESCRIPTION **** (Based on Fire Resistance Ratings UL 827, Tables 4.1) Occupancy Single Multiple Sprinkler System Yes No Automatic Fire Alarm System Yes No Exterior Bearing Wall Construction Interior Bearing Wall Construction Support Beams Construction Support Columns Construction Truss or Joist Construction Floor/ceiling construction (If multiple story, list each floor/ceiling assembly.) If known, please provide the following information: Design, or fire resistance ratings of any combustible structural members, which comprise the building (Design Ratings based on current UL Fire Resistance Directory Vols. 1 & 2, or an Architect s documentation)
6 Roof construction Roof covering Class A covering? NOTE: All interior doors and frames installed within walls that require a fire resistance rating; shall be UL fire rated for a minimum of 45 minutes. Location/Floor **** CENTRAL STATION OPERATING ROOM **** If central station is housed in a multiple occupancy building, please describe construction of any combustible walls, floors, and ceilings enclosing the central station operating room. Physical Security of the Station: Do walls enclosing Operating Room extend to the roofline or fixed assemblies? Yes No Construction of Entry Door(s): Is an Automatic Door Closer Installed? Yes No Is a manual means of identification installed? Yes No Can the door be readily left in an unlocked position? Yes No If an electric strike is used, is standby power provided? Yes No
7 Are there windows in the Operating Room? Yes No Describe the protection of any windows that are accessible from outside of the alarm service company s offices: **** POWER/GENERATOR ROOM (S) CONSTRUCTION **** Location/Floor Power Room Wall Construction Power Room Floor Construction Ceiling Construction
8 Door(s) & Frame(s) Construction If located indoors, are door(s) & frame(s) UL fire rated? Yes No Burglar Alarm Supervision Yes No Fire Alarm Supervision Yes No Ventilation Yes No If generator is located out of doors, please describe type of security: **** CENTRAL STATION STAFF **** No. on Duty per Shift Shift Operator(s) Runner(s) at Central Station Runner(s) at Runner Station
9 **** CENTRAL STATION EQUIPMENT **** TELEPHONE CABLE NOTE: Telephone conductors carrying signal and communications circuits into the building housing the central station shall be protected against mechanical damage, fire, and attack by methods outlined in UL 827, Section -10 Cable System. Please describe protection and routing of the telephone cable serving the central station: IF APPLICABLE: An antenna cable connecting a radio antenna to radio receiving and/or transmitting equipment located in a building housing the central station, and used to process UL Listed alarm signals shall be protected against fire, mechanical damage, and attack by the methods outlined in UL 827, Section Antenna Cable. Please describe protection and routing of the antenna cable serving the central station:
10 **** CENTRAL STATION RECEIVING EQUIPMENT **** RECEIVERS No. Units Manufacturer Model No. Connected to Automation System AUTOMATION EQUIPMENT Software Provider Version Main Computer Mfg. Model No. Redundant System? Yes No Total Systems Monitored Total Systems with Openings/Closings UPS Installed? Yes No
11 **** SECONDARY POWER SUPPLY **** NOTE: Required standby power shall be in accordance with UL 827, Section 9 Power Supply (Please check box which best describes standby power) 24 hour Battery Supply with Rectifiers (s) or UPS [ ] Generator and 4 hour Battery Supply [ ] Two generators, one with auto start [ ] BATTERY CHARGERS Internal to the Receivers Yes No (If chargers are part of the receivers, proceed to the next section) External to the Receivers Yes No No. Units Manufacturer Model No. Output Rating V A V A GENERATOR(S) Mfg. Model Rating Mfg. Model Rating
12 UNINTERRUPTIBLE POWER SOURCE Mfg. Model Rating Mfg. Model Rating Battery Mfg.: Model No. UPS Bypass Switch (For Routine Maintenance) Run Time on UPS Batteries Additional Comments about any part of the Central Station:
13 RECORDS DESCRIPTION SHEET Fire Alarm System Record of Completion A document that acknowledges the features of installation, operation, service, and equipment with representation by the property owner, system installer, system supplier, service organization and the authority having jurisdiction. An example of a record of completion form can be found in NFPA 72. As-Built (Record) Drawings As-Built drawings are drawings that document the location of all devices, appliances, wiring sequences, wiring methods and connections of the components of the fire alarm system as installed. These drawings must consist of current fire alarm system shop drawings, showing the location of fire alarm system components, remote power extenders, control units or modules. The drawings must also show the actual location of each alarm detection device, and audible appliance. Drawings provided must reflect the actual system installed. Where drawings are not available due to the extended life of the system installed, duplicate drawings must be produced depicting the current installation. Full-scale cad drawings are not required for the UL evaluation. Smaller versions may be submitted or made available at the time of our evaluation. The drawings should be done to scale and include a legend identifying all symbols that are used. Battery Calculations A battery calculation for a central station system consists of recording the current drain of each component of the fire alarm system in the normal supervisory load, totaling the supervisory loads and multiplying by 24 hours. In addition, the current drain of each individual component when in alarm mode is also recorded, totaled and multiplied by 5 minutes. The results of these calculations are combined and multiplied by a safety factor to establish the minimum amperehour capacity of the standby batteries. Acceptance Test Record An acceptance test is a test of all parts of the alarm system by the alarm service company that is maintaining the system. The test methods are described in NFPA 72 and the results shall be individually recorded for each component, device, appliance, and conductor. Copy of Original Equipment Submittals Original equipment submittals include a description of all devices that make up the fire alarm system. The listing category, visual description, power requirement for each device, and limits of usage must be included. These documents may be submitted prior to our on-site visit or made available at the time of our evaluation. Operational Manuals
14 Manuals defining the proper operation of all fire alarm system control equipment and peripheral devices must be provided for the end user. Documents must correspond with equipment models currently installed in the system. Manufacturer s Proper Testing and Maintenance Requirements Testing shall be performed in accordance with the schedules and tables found in NFPA 72 or on a frequency approved by the authority having jurisdiction. Fire alarm system equipment shall be maintained in accordance with the manufacturer s instructions. Methods and instruments that measure certain parameters as required by the manufacturer must be provided at the time of our evaluation. As part of the testing required during our evaluation, the retransmission signal and the time of the retransmission shall be recorded in the central station. A record of these tests must be provided upon completion of our field investigation. Periodic Test and Inspection Forms The forms that are used to record periodic tests and inspections of fire alarm systems are required to display the each component, device, appliance and wiring that was tested and the tests that were conducted. Contracts Central station service requires the alarm service company establish contracts with the subscriber for the performance of inspection, testing, maintenance, monitoring, signal processing and runner service. A Listed local company may in turn subcontract the monitoring and signal processing to a UL Listed central station.
15 PROTECTED PROPERTY EVALUATIONS CHECKLIST & DATA SHEETS One set of the following Checklist & Data Sheets should be completed for each fire alarm system to be evaluated. These must be returned with the pre-audit data sheets when you accept our quote. Confirmation Checklist Please confirm that all requested items will be available in your office at the time of our visit by placing a check mark to the right of each item, sign and date as indicated below. Required Documents Fire Alarm System Record of Completion As-built (Record Drawings) Operational Manuals, (Verified on hand at premise or at the alarm service company office) Manufacturer s Testing and Maintenance Requirements, (Verified on hand at premise or at the alarm service company office) Battery Calculations Copy of forms used to record periodic test and inspections Required Contracts Acceptance Test records (Signature) (Date)
16 UL LLC FIRE ALARM SYSTEM PRE-EVALUATION DATA SHEETS Please Return Completed Forms to UL Prior to Audit Name: PROTECTED PROPERTY Address: City: State: Zip Code: ALARM SERVICE COMPANY Service Center No: Name: Address: City: State: Zip Code: Representative: (Name & Title) Phone Number: ( ) COMMENTS AND CLARIFICATIONS Note: Clarify Location or Area of Coverage, as Needed
17 ALARM SYSTEM DESCRIPTION SYSTEM TYPE Select Type of System: CENTRAL STATION SERVICE - NFPA REMOTE SUPERVISING STATION NFPA PROPRIETARY SUPERVISING STATION - NFPA LOCAL ALARM SYSTEM - NFPA 72 Edition (year) Area Covered/Location: (Building(s), Floor(s), or Areas(s)) System Testing and Maintenance: Date of Periodic Testing and Maintenance Contract: Note: Variations in Testing and Maintenance Procedures from Standard shall be shown in Deviations Section: AUTHORITY HAVING JURISDICTION AHJ Responsible for System: (Specify Name and Phone Number) Responding Fire Department: AUTOMATIC FIRE DETECTION AND ALARM SERVICE Coverage: (Select One) Total Selected Area Partial Total Detectors are installed in all rooms, halls, storage areas, basements, attics, lofts, spaces above suspended ceilings, and other subdivisions and accessible spaces as well as the inside of all closets, elevator shafts, enclosed stairways, dumbwaiter shafts, and chutes. Selected Area Same code requirements as total coverage but protection is only provided for a specifically defined area(s) of the protected property. Indicate specific areas protected in Comments Section Page 1. Partial Deviations from Total or Selected Area coverage. Protection provided as required by the AHJ in areas such as common areas and work spaces, such as corridors, lobbies, storage rooms, equipment rooms, and other tenantless spaces. Quantity: Type: Smoke Detectors Heat Detectors Duct Detectors Other Specify:
18 SPRINKLER SYSTEM WATERFLOW ALARM AND SUPERVISORY SERVICE Note: If all sprinkler risers and waterflow shutoff valves are not supervised, show in Deviations Section Type of System: Wet Pipe Dry Pipe Quantity: Type: Waterflow Switches Sprinkler Valve Supervisory Switches Other Supervisory Services: Quantity: Type: Water Pressure Devices Water Temperature Devices Water Level Devices Air Pressure Devices Room Temperature Devices Fire Pump Power Devices Fire Pump Running Devices Other Specify: MANUAL FIRE ALARM AND GUARD S TOUR SUPERVISORY SERVICE Note: If proper number of fire alarm boxes required by standard is not installed, show in Deviations Section Quantity: Type: Manual Fire Alarm Boxes Guard Tour Stations Combination Manual Fire Alarm and Guard Tour Stations ALARM NOTIFICATION AND ANNUNCIATION DEVICES Note: If quantity and location of alarm notification devices does not comply with the Standard, show in Deviation Section Quantity: Type: Horns Bells Chimes Visual Signals Type: Strobe Light Graphic Audible/Visual Signals Type: Strobe Light Graphic Other Specify:
19 EMERGENCY VOICE ALARM SERVICE Quantity: Type: Speakers Voice Alarm channels Speaker Zones Telephone Jacks CONTROL PANEL COMPONENT DESCRIPTION Manufacturers and Model Numbers. Indicate model numbers and manufacturers of all control units, sub-controls, annunciators, transmission devices, power supplies, and any components used within these units. Quantity: Manufacturer & Model Number: Description: If Additional space is needed, please attach separate sheet ALARM TRANSMISSION METHOD Circle those that apply: Digital Alarm Communicator Radio System (two-way) Radio System (one-way) Cellular Digital Communicator Multiplex Derived Channel Direct Wire Internet
20 SUPERVISING MONITORING STATION Name: Address: City: State: Zip Code: UL File Number: Service Center Number: SYSTEM DOCUMENTATION Note: The following must be checked as available for all systems: Fire Alarm System Record of Completion As-Built (Record) Drawings Operational Manuals Manufacturer s Installation Instructions Battery Calculations Copy of Form used to Record Periodic Test and Inspection Required Contracts SYSTEM DEVIATIONS FROM REFERENCED NFPA STANDARDS Note: If service provided (i.e. periodic testing, maintenance, response, or coverage) is not in accordance with NFPA Standard specified, the details must be shown on this section.
PROTECTED PROPERTY. City: State: Zip Code: ALARM SERVICE COMPANY. City: State: Zip Code: COMMENTS AND CLARIFICATIONS ALARM SYSTEM DESCRIPTION
Underwriters Laboratories Inc. FIRE ALARM SYSTEM PRE-INSPECTION DATA SHEETS PLEASE RETURN COMPLETED FORMS TO UL PRIOR TO INSPECTION PROTECTED PROPERTY City: State: Zip Code: ALARM SERVICE COMPANY File
More informationCOMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE
COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE SUPERVISION OF AUTOMATIC FIRE SPRINKLER SYSTEMS SUPERVISION OF ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS FIRE ALARM AND DETECTION SYSTEMS The Fire Alarm
More informationIdaho Surveying & Rating Bureau, Inc South Cobalt Point Way Tel: (208) Meridian, Idaho FAX: (208)
Idaho Surveying & Rating Bureau, Inc. 1871 South Cobalt Point Way Tel: (208) 343-5483 Meridian, Idaho 83642 FAX: (208) 895-8059 www.isrb.com e-mail info@isrb.com Joseph C. Harbacheck, CIC Secretary - General
More informationFIRE & LIFE SAFTEY STANDARD
Title: Effective Date: 01/01/14 Revised Date: 1/1/14 Code References: Title 16, Chapter 16.16 of the Roseville Municipal Code, NFPA 72 Note: This standard is a summary of Fire Department clarifications
More informationUnified Fire Authority - Fire Prevention Bureau
Unified Fire Authority - Fire Prevention Bureau FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance
More informationSECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM
SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationEl Reno Fire Department Fire Alarm Plan Review Worksheet
El Reno Fire Department Fire Alarm Plan Review Worksheet This Fire Alarm Plan Review Checklist is provided as a guide to assist with your Fire Alarm Plan Review Submittal requirements. Please contact us
More informationINSPECTION AND TESTING FORM
INSPECTION AND TESTING FORM Date: Time: SERVICE ORGANIZATION Name: Address: Representative: License No.: MONITORING ENTITY Contact: Monitoring Account Ref. No.: TYPE TRANSMISSION McCulloh Multiplex Digital
More informationCITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST
CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST DATE: PROJECT NO.: EXPIRATION DATE: STATUS: INFORMATION PROJECT ADDRESS:
More informationStandard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.
A28.1 Standard of Practice - Fire Alarm Systems NOTE: Significant revisions or additions to the previous standards are highlighted in italics. OBJECTIVE OF STANDARD To provide compliant smart addressable
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved; AC-Approved
More informationCAN/ULC-S561. To comply, or not to comply. actually it s not even a question! Underwriters Laboratories of Canada. By Alan Cavers & Brian McBain
CAN/ULC-S561 To comply, or not to comply. actually it s not even a question! By Alan Cavers & Brian McBain CAN/ULC-S561, Installation And Services For Fire Signal Receiving Centres And Systems is without
More informationMoreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline
Moreno Valley Fire Department Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: May 8, 2017 Alarm & Signaling Systems PURPOSE Fire alarm and signaling systems are designed to
More informationSANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)
FIRE DEPARTMENT SANTA CLARA COUNTY 14700 Winchester Blvd., Los Gatos, CA. 95032-1818 (408) 378-4010 (408) 378-9342 (fax) www.sccfd.org STANDARD DETAILS & SPECIFICATIONS Spec No C-4 Rev. Date 03/10/10 SUBJECT:
More informationNational Industrial Security Monitoring Station Evaluation
National Industrial Security Monitoring Station Evaluation Listing Evaluation During the UL Listing evaluation we will examine your the monitoring facility, signal handling, means of record keeping, and
More informationBrighton Area Fire Authority
615 W. Grand River Ave. Brighton, MI 48116 o: 810-229-6640 f: 810-229-1619 January 14, 2019 Fire Alarm Contractors RE: Fire Alarm Credential & Submittal Requirements To Whom It May Concern: The following
More informationNFPA 72 Code Changes vs 2013
NFPA 72 Code Changes - 2010 vs 2013 AFAA-NE Westborough, MA February 7, 2018 Richard Roux NFPA 72 National Fire Alarm and Signaling Code Overview and 2013 Changes NFPA 72 1993 Edition Aug 20, 1993 1996
More information2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.
2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge. Exception: Manual fire alarm boxes are not required where the building is
More informationRancho Cucamonga Fire Protection District Prevention Bureau Standard
Rancho Cucamonga Fire Protection District Prevention Bureau Standard Title: Fire Alarm and Monitoring Systems Standard # 9-3 Effective: May 2002 Number of Pages: 7 Updated: December 2016 for consistency
More informationValuation: # of Plans Submitted: # of pages: Type of Work (select one): New Addition Existing System/Modification Project Name: Scope of Work:
PERMIT FEE: $ 907 Billy Mitchell Blvd. P: (210) 228-1022 Fire Alarm Permit Application PAYMENT TYPE: Check Credit Card Charge to Job #: (Please complete all of the following information. Please PRINT).
More informationChanges in NFPA
Changes in NFPA 72-2002 2002 Oregon Fire Code Committee November 25, 2003 Michael B. Baker, SET Automatic Fire Alarm Association MikeBaker@afaa.org 2003 Michael B. Baker 1 Table of Contents 1. Administration
More informationYou are required to READ ALL PAGES. of this application
Fire/Smoke/Heat/CO Application Checklist You are required to READ ALL PAGES of this application NEW ROCHELLE FIRE DEPARTMENT 90 Beaufort Pl, New Rochelle, NY 10801 - (914) 654-2213 APPLICATION FOR FIRE/SMOKE/HEAT/CO
More informationMOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Alarm System Plan Review 2009 International Fire Code and 2010 NFPA 72 Date of Review // BLD201 - Project Address: Project Name: _ Professional
More informationMINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry
MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Fire Alarm Systems Plan Review Checklist Date: Permit Number: Business Name: Address: Fire Alarm System Submittal
More informationChapter 4: Fire Protection Systems
Chapter 4: Fire Protection Systems Automatic Extinguishing Systems (Fire Sprinklers) One of the most important aspects of a storage warehouse inspection is ensuring that the automatic extinguishing system
More informationBold items are particular to the City of Euless
EULESS FIRE DEPARTMENT FIRE MARSHAL S OFFICE INFORMATION LINE: Revised 8/2004 Fire Chief Lee Koontz Fire Marshal Paul Smith EFD-FMO 3-1 2003 International Fire & Building Code as Amended NFPA Standards
More informationFlorida Building Code Chapter 9 Fire Protection Systems Advanced Course
Florida Building Code 2010 Chapter 9 Fire Protection Systems Advanced Course 1 Introduction This course will cover specific sections of Chapter 9 that relate to fire alarm systems. While many contractors
More informationTABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2
Division 28 ELECTRONIC SAFETY AND SECURITY TABLE OF CONTENTS 28 0000 GENERAL... 2 A. DEFINITIONS...2 28 3111 DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2 A. DESIGN REQUIREMENTS...2 B. CONSTRUCTION REQUIREMENTS...2
More information109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:
109-B Concord Drive Casselberry, FL 32707 407.830.6500 DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72 Pg 1 of 4 Equity One 11180600 Owner/Representative: WO#: _Customer#: 1550 NE Miami Garden Dr
More informationHinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM
SECTION 28 3111 DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Fire-alarm control unit. 2. Manual fire-alarm boxes. 3. System smoke detectors. 4. Heat detectors.
More informationFire - Rescue. November 2016
Fire - Rescue Fire Alarm and Central Station Monitoring Plan Submittal Guidelines November 2016 Plan Submittal Guidelines are provided based on the 2015 International Fire Code, Policies, and Local Amendments.
More informationFIRE ALARM APPLICATION CITY OF MADISON HEIGHTS
FIRE ALARM APPLICATION CITY OF MADISON HEIGHTS www.madison-heights.org COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 300 W. THIRTEEN MILE RD. MADISON HEIGHTS, MICHIGAN 48071 (248) 583-0831 FAX (248)
More informationPWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R
Region Project Page 1 PART 1 - GENERAL 1.1 REFERENCES.1 CAN/ULC-S524-2006, Standard for the Installation of Fire Alarm Systems..2 CAN/ULC-S525-2007, Audible Signal Device for Fire Alarm Systems..3 CAN/ULC-S526-2007,
More informationSTATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT
STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT The interaction of fire protection systems can be extremely complex. The detection of a fire in a building by an automatic device
More informationType of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number:
DATE OF SUBMISSION TO: Department of Licenses and Inspections Commercial and Industrial Fire Inspection Unit 990 Spring Garden Street, 3 rd Floor, Philadelphia, PA 19123 AP# CITY OF PHILADELPHIA FIRE ALARM
More informationFire Alarm, Water Flow Alarm & Signaling Systems
Orange County Fire Authority Community Risk Reduction 1 Fire Authority Road, Building A, Irvine, CA 92602 www.ocfa.org 714-573-6100 Fire Alarm, Water Flow Alarm & Signaling Systems Guideline D-03 Serving
More information1 Exam Prep Fire Alarm Signaling Systems Tabs and Highlights
1 Exam Prep Fire Alarm Signaling Systems Tabs and Highlights These 1 Exam Prep Highlights are based on the Fire Alarm Signaling Systems, 4th Edition. Each Tabs sheet has five rows of tabs. Start with the
More informationNational Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:
National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Notification
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST FIRE AND LIFE SAFETY SYSTEMS FOR STRUCTURES FIVE OR MORE STORIES IN HEIGHT AND LESS THAN 75 FEET IN HEIGHT FROM THE POINT
More informationFire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting. Prepared Especially for : OSFM TEC 2016
Fire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting Prepared Especially for : OSFM TEC 2016 Acceptance Testing 11-2008 Agenda Before you begin Completing the
More informationChapter 17, Initiating Devices
Chapter 17, Initiating Devices Summary. Chapter 17 was Chapter 5 in NFPA 72-2007. The term authority having jurisdiction is replaced in some sections by the term other governing laws, codes, or standards.
More informationAgency for Health Care Administration
Page 1 of 100 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS CFR Type Memo Tag FED - K9999 - FINAL OBSERVATIONS Title FINAL OBSERVATIONS CFR Type Memo Tag FED - KA100 - General Requirements - Other
More informationSecond Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement
of 1 9/22/2014 1:38 PM Second Revision No. 104-NFPA 72-2014 [ Section No. 3.3.3 ] 3.3.3 Accessible, Readily (Readily Accessible). Capable of being reached quickly for operation, renewal, or inspections
More informationCITY OF PORTSMOUTH Department of Public Works MUNICIPAL COMPLEX FIRE ALARM. Bid # Addendum #1
CITY OF PORTSMOUTH Department of Public Works MUNICIPAL COMPLEX FIRE ALARM Bid #56-09 Addendum #1 This Addendum forms part of the original document marked Bid #56-09 MUNICIPAL COMPLEX FIRE ALARM. Device
More informationNational Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:
National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Notification Appliances
More informationSTANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018
STANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018 STANDARD INFORMATION Standard Number: NFPA 72 Standard Name: National Fire Alarm and Signaling Code Standard Edition and Issue Date: 2016 Edition
More information1.3 REFERENCE STANDARDS
SECTION 28 4600 FIRE DETECTION AND ALARM PART 1 -GENERAL 1.1 SECTION INCLUDES A. Fire alarm system design and installation, including all components, wiring, and conduit. B. Circuits from protected premises
More information2019 COURSE CATALOG (rev )
2019 COURSE CATALOG (rev. 02.07.19) www.afaa.org CEUs Available for NICET, Engineers and Other! 3246 Noe-Bixby Road, Suite 101, Columbus, OH 43232 844-438-2322 Page 1 Page No. Seminar Name 3. A User s
More informationMECKLENBURG COUNTY FIRE MARSHAL S OFFICE
Effective Date: 11/01/02 Purpose: MECKLENBURG COUNTY To establish a set of guidelines for performance testing of all newly installed or upgraded fire alarm systems in order to ensure that all devices and
More informationSECTION FIRE ALARM SYSTEMS
SECTION 28 3100 PART 1 -GENERAL 1.01 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this
More informationFlorida Building Code 2010
Introduction Florida Building Code 2010 Chapter 9 Fire Protection Systems This course will cover specific sections of Chapter 9 that relate to fire alarm systems. While many contractors are familiar with
More informationNarrative Reports As Regulated by 780 CMR, Section 903.0
EXHIBIT 20 Narrative Reports As Regulated by 780 CMR, Section 903.0 903.1.1 - FIRE PROTECTION CONSTRUCTION DOCUMENTS a. Basis (methodology) of design for the protection of the occupancy and hazard for
More informationALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST
OPTIONAL INFORMATION Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: ALARM SYSTEMS AND EVACUATION PLANS Guidelines: This checklist covers regulations issued
More informationAGENDA NFPA TECHNICAL COMMITTEE ON NOTIFICATION APPLIANCES. Report on Comments Meeting, October 13-14, Richmond Marriott, Richmond, VA
National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org AGENDA NFPA TECHNICAL COMMITTEE ON NOTIFICATION APPLIANCES Report on Comments
More informationDate Issued: December 14, 2017 Revision: 2.1
2.1 1. Introduction A is implemented to ensure the fire safety of building occupants or a building area when the Fire Alarm System or a Fire Protection System has been temporarily disabled due to malfunction,
More informationFunctional Performance Test
Fire Alarm Control Panel & Fire Alarm Annunciator Panel Notify all building occupants that testing will be conducted. Fire alarm contractor shall have personnel with 2-way radios at the fire alarm control
More informationFire Protection Coffee Break Training May 2016
Fire Protection Coffee Break Training May 2016 Introduction High-Rise Requirements Questions and Answers Agenda Overview Site Fire Access Aerial Access Power/Back-up Power Elevators and Access Sprinklers
More informationApplying Performance-based Fire Alarm System Design Part 4
Fire Alarm Notebook by Dean K. Wilson. P.E. Page 1 Applying Performance-based Fire Alarm System Design Part 4 by Dean K. Wilson, P.E. Over the course of the last four issues I have continued to discuss
More informationUniversity Design Standard Fire Alarm Systems
1.0 Overview University Design Standard Fire Alarm Systems This document provides Virginia Tech s standards for the design and installation of fire alarm systems and equipment in new construction, retrofit
More informationMichigan State University Construction Standards COMMISSIONING OF FIRE ALARM SYSTEMS PAGE
PAGE 280800-1 SECTION 280800 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification
More informationSECTION : FIRE ALARM & DETECTION SYSTEMS
SECTION 28 31 10: FIRE ALARM & DETECTION SYSTEMS 1. GENERAL A. This section applies to fire detection/alarm system and carbon monoxide system components and equipment installed during new construction
More informationCLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau
CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 Permit Type: 105.6.54 Control Number: A.0 Effective Date: TITLE: PROPRIETARY
More informationFIRE SAFETY REQUIREMENTS FOR PRE RESIDENTIAL BUILDINGS OF THREE OR MORE STORIES (DOROTHY MAE ORDINANCE - NO. 158,963)
INFORMATION BULLETIN / PUBLIC - MECHANICAL CODE REFERENCE NO.: LAMC 91.8604 Effective: 6-20-84 DOCUMENT NO. P/MC 2002-005 Revised: 6-15-00 Previously Issued As: MGD #74 FIRE SAFETY REQUIREMENTS FOR PRE-
More informationAutomatic Fire Alarm Association Webinar On Inspection, Testing, And Maintenance Of Fire Alarm Systems
Automatic Fire Alarm Association Webinar On Inspection, Testing, And Maintenance Of Fire Alarm Systems Your Presenter: Merton Bunker, PE Inspections and tests are intended to reduce or limit: Loss of life
More informationHIGH-RISE RETROFIT ORDINANCES - NO and NO
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LAMC 91.8604 Effective: 9-06-90 DOCUMENT NO. P/BC 2002-054 Revised: 4-15-03 Previously Issued As: MGD 88 HIGH-RISE RETROFIT ORDINANCES - NO.
More informationSECTION 907 FIRE ALARM AND DETECTION SYSTEMS
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS 907.1 General. This section covers the application, installation, performance and maintenance of fire alarm systems and their components in new and existing
More informationFire Alarm Testing and Inspection Report
Fire Alarm Testing and Inspection Report Property Name: Property Address: Property Manager: Contact: Phone Number: Central Station: Phone Number: PELICAN ISLE II 35 DOCKSIDE RD. NAPLES, FLORIDA 3110 BILL
More informationAgency for Health Care Administration
Page 1 of 51 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS CFR Type Memo Tag FED - K0130 - MISCELLANEOUS Title MISCELLANEOUS OTHER LSC DEFICIENCY NOT ON 2786 FED - K9999 - FINAL OBSERVATIONS Title
More informationFacilities Management
Facilities Management Policy Number: 700.4 Title: Fire Protection & Life Safety Inspection Policy Implementation Date: August 1 st, 2008 Last Revised: September 14 th, 2017 Last Audited: August, 2017 Introduction
More informationFort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS
HVAC Upgrades Phase 2 Page 1 of 5 Part 1 General 1.1 SUMMARY.1 Section Includes:.1 Materials and installation for fire alarm systems upgrades..2 Audible signal devices..3 End-of-line devices..4 Sustainable
More informationAgency for Health Care Administration
Page 1 of 92 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Type Memo Tag FED - K9999 - FINAL OBSERVATIONS Title FINAL OBSERVATIONS Type Memo Tag FED - KA100 - General Requirements - Other Title
More informationProject No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10
Belleville, Ontario Page 1 of 10 1 GENERAL 1.1 GENERAL REQUIREMENTS.1 The General Conditions of CCDC2-2008, and the General requirements of Division 1, form part of this Section and must read in conjunction
More informationThe Standard for Remote Supervising Station (SRSS-01) 2007
The Standard for Remote Supervising Station (SRSS-01) 2007 Electronic Security Association 2300 Valley View Lane, Suite 230 Irving, TX 75062 888-447-1689 1 The Standard for Remote Supervising Station (SRSS-01)
More informationSurviving Survivability A User s Guide to Survivable Fire Alarm Circuits Larry D. Rietz, SET 23 May 2018
Surviving Survivability A User s Guide to Survivable Fire Alarm Circuits Larry D. Rietz, SET 23 May 2018 Automatic FireAlarm Association SURVIVING SURVIVABILITY - A USER S GUIDE TO Larry D. Rietz, SET
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 21 0800 - COMMISSIONING OF FIRE SUPPRESSION SYSTEMS GENERAL 1.1 SUMMARY General 1. Work under this contract shall meet the requirements of Division 01, General Requirements, Conditions of Contract,
More informationFire Permit Application
Fire Permit Application FOR STAFF USE ONLY Case Permit Number: Plan Number: Related permits: Project #: Responsibility for information Although designated Department staff members will help you with general
More informationLake County / Multi-Department Storage Facility / Project / December 12, 2016 SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM
PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 283111 A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationFire Alarm and Life Safety System Inspection Certificate
Fire Alarm and Life Safety System Inspection Certificate For Sample FireScan Healthcare 123 Main Street Anytown, State 55555 Tested to NFPA 72 Standards, 2007 Edition This Inspection was performed in accordance
More informationSmoke Detector Activation of any smoke detector shall start the alarm verification mode.
Description: The purpose of the section is to provide the UMCP Design Standards for the design and implementation of Fire Alarm Systems at the UMCP campus. Related Sections: TBD Effective Date: July 10,
More informationMANUAL OF DESIGN CRITERIA AND SPECIFICATIONS FOR FIRE DETECTION AND ALARM SYSTEMS PUBLIC SCHOOLS IN NEW MEXICO
MANUAL OF DESIGN CRITERIA AND SPECIFICATIONS FOR FIRE DETECTION AND ALARM SYSTEMS PUBLIC SCHOOLS IN NEW MEXICO Prepared For: Public Schools Facilities Authority State of New Mexico 2019 Galisteo, Suite
More informationFire Alarm System Fundamentals
Fire Alarm System Fundamentals Mircom is the largest and oldest privately owned fire alarm and life safety manufacturer in North America and 5th largest overall with 50 years of industry experience. Mircom
More informationUpdate all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.
11/16/12 TerraView First Revision No. 15-NFPA 720-2012 [ Global Input ] Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.
More informationFire Alarm System Inspection and Testing Report
Fire Alarm System and ing Report Date of : Time of : 1. PROPERTY INFORMATION: Name of Property: Address: of property: Occupancy Type: Name of property representative: Address: Phone: Fax: E-mail: Local
More informationElectronic Safety and Security
28 Electronic Safety and Security NOTE: This is a new section, which includes content from previous sections of the KU Design Standards, along with appropriate revisions and updates. Significant revisions
More informationFIRE ALARM SYSTEM INSPECTION
13555 Wellington Center Circle Suite 123 Gainesville, VA 20155 T: 1-888-883-2867 F: 703-468-6070 www.vectorsecurity.com FIRE ALARM SYSTEM INSPECTION Upon arrival, contact Vector Security Service Dept.
More informationEL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD
EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD Installation of Residential Fire Sprinkler Systems STANDARD #C-002 EFFECTIVE 03-19-2009 PURPOSE: To ensure that sprinkler plans submitted for review contain
More informationAIRPORT OFFICE BUILDING. Smoke Control System. Testing Procedures Manual. September 10, 2016
IMPACT ENGINEERING, INC. AIRPORT OFFICE BUILDING Smoke Control System Testing Procedures Manual September 10, 2016 All Rights Reserved This manual is protected by the U.S. Copyright Law (Title 17 United
More informationSECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD
PART 1 - GENERAL PURPOSE This Standard is intended to assure that fire detection/alarm systems at The University of Texas at Austin provide the highest level of fire safety possible. SCOPE This standard
More informationSECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM
SECTION 13852- PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this
More informationrpsa FIRE PROTECTION ENGINEERS
FIRE PROTECTION ENGINEERS R.P. SCHIFILITI ASSOCIATES, INC. P.O. Box 297 Reading, Massachusetts 01867-0497 USA 781.944.9300 Fax / Data 781.942.7500 Telephone Elevator Fire Safety: Elevator Recall and Elevator
More informationM E M O R A N D U M. Technical Committee on Supervising Station Fire Alarm and Signaling Systems
National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Supervising Station
More informationSECTION FIRE ALARM
SECTION 16740 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this
More informationCrime Central Station Burglary Alarm Systems
Page 1 of 10 Scope This criteria is intended to provide Loss Control Representatives with specific guidelines and information for evaluating central station burglar alarm systems for risks carrying crime
More informationCOMMISSION ORDER. IT IS FURTHER ORDERED that the Request for Bid and Notice to Bidders be displayed on the Franklin County website.
4.e STATE OF MISSOURI County of Franklin ss. COMMISSION ORDER Commission Order No. 2016-316 Third Quarter Term 2016 Tuesday,August,09,2016 Bid Notice IN THE MATTER OF ADVERTISING FOR SEALED BIDS FOR SMOKE
More informationNational Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:
National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Testing and Maintenance
More informationFire Sprinkler System Design and Installation Requirements
Fire Sprinkler System Design and Installation Requirements The Park City Fire Service District (PCFD) and Park City Municipal Corporation (PCMC) have made the following amendments to the State of Utah
More informationFIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS
VALOUR COMMUNITY CENTRE FIRE ALARM SYSTEM Section 28 00 00 GYMNASIUM ADDITION & RENOVATION Page 1 of 3 28 00 00 FIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS 1.2 SCOPE 1. The specification covering the General
More informationSECTION ADDRESSABLE FIRE ALARM SYSTEM
SECTION 16720 - ADDRESSABLE FIRE ALARM SYSTEM PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationConstruction and Development Guide
Construction and Development Guide **Based on the 2014 Indiana Fire Prevention Code and relevant NFPA Codes and Standards ** Copyright 2018 Clay Fire CRRD 1 P a g e Table of Contents Map of Jurisdiction...
More informationAUTOMATIC FIRE SPRINKLER SYSTEMS
MCKINNEY FIRE DEPARTMENT FIRE MARSHAL S OFFICE AUTOMATIC FIRE SPRINKLER SYSTEMS These guidelines are to be followed when a business, facility or organization installs an automatic fire sprinkler system
More information