Ex-d luminaire type dklk 23 (V-CG-S) GHG W. Flameproof enclosure 'd', Equipment dust ignition protection by enclosure 't' Dr. F.
|
|
- Isabella Martin
- 5 years ago
- Views:
Transcription
1 '. IECEx Certificate INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certitication Scheme tor Explosive Atmospheres for rules and details of the IECEx Scheme visil Certificale No.:. IECEx BVS issue No.2: Certificale hislory: Issue No. 2 ( ) Status: Current : Issue No. 1 ( ). ; Issue No. 0 ( ) Date of Issue: Page 1 of 6 Applicant: Cooper Crouse-Hinds GmbH Neuer Weg-Nord Eberbach Electrical Apparatus: Oplionalaccessory: Ex-d luminaire type dklk 23 (V-CG-S) GHG W Type of Protection: Flameproof enclosure 'd', Equipment dust ignition protection by enclosure 't' Marking: Ex d IIC T6 Gb Ex tb IIiC T80 C Db Approved for issue on behalf of the IECEx Certificalion Body: Position: Dr. F. Eickhoff Deputy Head of Certification Body Signa/ure: (for printed version) Date: 101/1.- C':) e., - 'Zr" 1. This cerlificale and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website. Certificate issued by DEKRA EXAM GmbH Dinnendahlstrasse Bochum 1> DEKRA DEKRA EXAM GmbH
2 Date of Issue: Issue No.: 2 Page 2 of 6 Manufacturer: Cooper Crouse-Hinds GmbH Neuer Weg-Nord 49, Eberbach Manufacturing location(s) S.C. Cooper Industries Cooper Crouse-Hinds Romania S.R.L. GmbH ARAD, Zona Industrial NV str Neuer Weg-Nord 49, III,no, Eberbach Romania This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents ' as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC : 2011 Edition: 6.0 IEC : Edition: 6 IEC : 2008 Edition: 1 Explosive atrnospheres - Part 0: General requirements Explosive atmospheres - Part 1: Equipment protection by f1ameproof enclosures "d" Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure 't' This Certificate does not indieate camp/ianee with e/ectriea/ safety and performance requirements other than those express/y ine/uded in the Standards listed above. TEST & ASSESSMENT REPORTS: A samp/e(s) of the equipment listed has successfully met the examination and test requirements as reeorded in Test Report: DE/BVS/ExTR100003/02 Quality Assessment Report: DE/BVS/QAR /01 DE/BVS/QAR /00
3 Date of Issue: Issue No.: 2 Page 3 of 6 Schedule EQUIPMENT: Equipment and systems covered by this certificate are as foliows: Description:! The flameproof luminaire dklk 23 (CG-S) is suitable for use in hazardous areas zone 1 and zone 2 as weil as zone 21! and 22. It is used as luminaire, signallamp, and as weil as an emergency lamp in conneclion with the emergency sign cube.! The position of lhe lamp as weil as the ambient temperature range may be limited according to the data given in "ratingthermal parameters". CONOITIONS OF CERTIFICATION: NO
4 Certificate No.: IECEx BVS Date of Issue: Issue No.: 2 Page 4 of 6 EQUIPMENT(continued): electrical parameters: rated voltage to 690 V/50 Hz. rated power dissipation 18 W rated current 0.05 A (110 V AC/DC), or 0.025A (230 V ACIDC) rated isolation current to 750 V!thermal parameters: permitted ambient temperature range mounting position light beam facing up 5 W lamp without security sign cube -20 oe C 5 W lamp with security sign cube -20 C C mounting position light beam facing down 5 W lamp without security sign cube -20 C +45 C 5 W lamp with security sign cube -20 C +45 C mounting position light beam facing down 10 W lamp without security sign cube -20 C +45 oe, 10 W lamp with security sign cube -20 oe +40 oe mounting position light beam facing down 15 W lamp without security sign cube -20 C +30 C 15 W lamp with security sign cube -20 C +30 C 6 W lamp without safety sign cube -20 oe +40 oe 6 W lamp with safety sign cube -20 C +40 C 7 W lamp without security sign cube -20 oe oe 7 W lamp with security sign cube -20 C +40 C 8 W lamp without security sign cube -20 oe oe 8 W lamp with security sign cube -20 oe oe flashlight lamp beam facing up 5Wlamp -20 oe oe, max. surface temperature T temperature class T6 I!degrees of protection according to EN IP66
5 Date of Issue: Issue No.: 2 Page 5 of 6 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): : The reason of the supplement is the updating to the standard IEC :2011 and the parameters have expanded for other luminaries. When used as an emergency lamp, the lamp has the additional marking V-CG-S.
6 Date of Issue: Issue No.: 2 Page 6 of 6 'Additional information: i Subject and type: 'Ex-d luminaire type dklk 23 (V-CG-S) GHG 871) 12) *3) *4) *5) * R * * * * : 1) Ex - Luminaire dklk 23 : 2) Type of apparatus 0- spaced 1 - dklk 23 3) Device version 1 - Compact lamp with integrated electronic ballast 2 - Emergency lamp 3 - Flash light lamp LED - Lamp : 4)Colour - protective cap o-limpid 1 - red 2 - green 3 - blue 4 - yellow. 5)Lamp efficiency 0 - without bulb (only valid for standard lamp) 1-5 W 2-7W 3-8W 4-6W 5 - free
Certificate No.: lecex BVS X issue No.:1 Certificate history: Issue No. 1 ( ) Status:
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the lecex Scheme visit www.iecex.com Certificate No.: lecex BVS 12.0057X issue No.:1
More informationIECEx Certificate of Conformity
Page 1 of 4 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate
More informationIECEx Certificate of Conformity
Page 1 of 10 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationIECEx Certificate of Conformity
Page 1 of 8 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate
More informationIECEx Certificate of Conformity
Page 1 of 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:1 Status: Current Certificate
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationINTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of Ihe IECEx Scheine visit www.iecex.com Certificate No.: Status: Date of Issue: Applicant:
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: IECEx CES 15.0002X Current
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:2 Status: Current Certificate history:
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:0 Certificate history: Status: Current
More informationIECEx Certificate of Conformity
Page 1 of 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:1 Status: Current Certificate
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:2 Status: Current Date of Issue: 2014-05-14
More informationIECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Certificate history: Status:
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:1 Status:
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:3 Status: Current Date of Issue: 2011-12-07
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: IECEx INE 10.0013X Current
More informationIECEx Certificate of Conform ity
IECEx Certificate of Conform ity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationCertificate of Compliance
Certificate of Compliance Certificate: 2325079 Issued to: Cooper Crouse Hinds GmbH Neuer Weg Nord 49 69412 Eberbach Germany Attention: Mr Günther The products listed below are eligible to bear the CSA
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx UL 13.0039U issue No.:1
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx UL 08.0012X issue No.:5
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No. : Status: Date of Issue: Applicant:
More informationINTERNATIONAL ELECTROTECHNICAL COMMISSlON IEC Certification Scheme for Explosive Atmospheres
INTERNATIONAL ELECTROTECHNICAL COMMISSlON IEC Certification Scheme for Explosive Atmospheres for rules and delails of lhe IECEx Scheme vtsit www.iecex.com Certificate No.: Status: Date of Issue: IECEx
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate IECEx
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:2 Status: Current Date of Issue: 2015-09-30
More informationIECEx Certificate of Conformity
Certificate : IECEx CSA 09.0001X Page 1 of 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:3 Status: Current Date of Issue: 2010-10-04
More informationIECEx Certificate of Conformity
Certificate of Conformity: IECEx SIR 09.0111 http://iecex.iec.ch/iecex/iecexweb.nsf/fc034777969a786bc1256d42005bd791/f076962... Page 1 of 3 22/01/2010 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx ETL 13.0026X Issue No:
More informationslra IEC of Gonformity IECEx Cert f cate ü* t4
-O fm INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.recex.com Certificate No Status: IECEx SIR 11.0156
More informationEnd of Life -Discussion on Ex Luminaires for Fluorescent Lamps in Zone 1? Not a Problem for Us! EVG 05
End of Life -Discussion on Ex Luminaires for Fluorescent Lamps in Zone 1? Not a Problem for Us! EVG 05 Tested and Certified According to the Latest Standards from March 2005 EOL (END OF LIFE) What is it?
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for ru les and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: Current issue No.:1
More informationsrra, of Conformity IECEx Gert f cate ?-ot,b
ts of Conformity I NTERNATIONAL ELECTROTECHNICAL COMMISSION IEG Gertification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.recex com Certificate No. ' IECEx SIR
More informationEX-SIGNAL- AND ESCAPE SIGN LUMINAIRS
1 EX-SIGNAL- AND ESCAPE SIGN LUMINAIRS 2 Co op er Cr ou se -H inds 20 08 - al l ri gh ts re se rv ed 3 4 5 6 7 8 EMERGENCY LIGHTING CENTRAL OR DECENTRAL 3.21 EX-ESCAPE SIGN LUMINAIRES EXIT EX-ESCAPE SIGN
More informationExplosion-proof Immersion Heater Type D-8660
Explosion-proof Immersion Heater Type D-8660 Sinus Jevi has developed explosionproof Ex de heating equipment, for hazardous area. The flame-proof (d) enclosures have been designed for non save areas to
More informationCertificate Number Baseefa04ATEXO245l4 lssued 4h June 2009 Page 1 of 2 SUPPLEMENTARY EC - TYPE EXAMINATION CERTIFICATE Equipment or Protective System Inte*:U":T#ilt*tentially Explosive Atmospheres 4 5
More informationFLASHLIGHT ANSI STANDARDS
FLASHLIGHT ANSI STANDARDS While Pelican was one of the first manufacturers to use quantifiable test procedures, the need was recognized to develop a common language that customers could use to select the
More informationManual Power relay SR853
Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death
More informationFLASHLIGHT ANSI STANDARDS
FLASHLIGHT ANSI STANDARDS While Pelican was one of the first manufacturers to use quantifiable test procedures, the need was recognized to develop a common language that customers could use to select the
More informationOfficine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0
Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:
More informationGRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S
www.stahl.de > Corrosion resistant omnidirectional high output sounder > Integrated Ex d enclosure > Extreme temperature range > 3 stage alarm with independant tone selection for V DC systems > IP66 IP67
More informationBattery supplied electronic ballast for emergency lighting EATON, EATON CROMPTON, EATON JSB or EATON MENVIER
CERTIFICATE Issued to: Applicant: Cooper Univel S.A. 88 Thessaloniki Street 1 00 Katerini, Greece Product Trade name(s) Type(s)/model(s) : : : Licensee: COOPER CSA S.R.L. Via San Bovio 3 - Edificio Y 090
More informationInductive slot sensor
0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output
More informationRegulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D
Regulated Ex-Heater HEX5-1.08 with internal controller, HEX5-2.08 with external controller II 3 G II 3 D Instruction Manual Version 1.02.00 Dear customer, we have made up this operating manual in such
More informationPRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres
PRODUCT OVERVIEW Light fittings, boxes & custom built control panels for explosive atmospheres LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4
More informationOPTIBAR DP 7060 Supplementary Instructions
OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,
More informationFlameproof Manual Call Points Series MCP
> Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied
More informationCertificate Surveillance audit
Certificate Surveillance audit The quality management System of the Company Manufacturer: R. STAHL Schaltgeräte GmbH Address: Am Bahnhof 30, 74638 Waldenburg, Germany 7 Site(s) of manufacture: R. STAHL
More informationAS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
Skip to main content Skip to primary navigation Home Home About this portal Latest updates Menu Print Save Email Resource detail Citations AS/NZS 60079.14:2009 Explosive atmospheres - Part 14: Electrical
More informationA Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document
A190325 Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document CONTENTS INTRODUCTION 1. DUAL CERTIFIED COMPONENTS 1.1 Simple Apparatus Switches For
More informationEXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X
EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ15.1137X Manufacturer: Product: Model Specification: Anti-explosion Mark: Topworx Inc. (Address: 3300 Fern Valley Road, Louisville, Kentucky
More informationEXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X
EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ15.1138X Manufacturer: Product: Model Specification: Anti-explosion Mark: Topworx Inc. (Address: 3300 Fern Valley Road, Louisville, Kentucky
More informationCertificate of Compliance
FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296
More informationReport No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor
Report No. 3040249EC FM Approvals Ltd 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT Product: Model and/or Type Reference: Flame Detector IPES-IR3 Description of the Product:
More informationManual for QX0201 Push Button
Manual for QX0201 Push Button Purpose of this Instruction Working in hazardous areas, the safety of personnel and plant depends on complying with all relevant safety regulations. Assembly and maintenance
More informationErik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories
Hazardous Locations: Understanding the Basics of Global Compliance Requirements Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories DISCLAIMER/ TERMS OF USE: THE INFORMATION
More informationTYPE APPROVAL CERTIFICATE
TYPE APPROVAL CERTIFICATE Certificate No: E-14378 This is to certify: That the Pilot Device with type designation(s) Pilot device Issued to BARTEC GmbH BAD MERGENTHEIM, Germany is found to comply with
More informationCertificate of Compliance
Certificate of Compliance Certificate: 2557738 Master Contract: 256526 Issued to: Bartec Varnost d.o.o Cesta 9 avgusta 59 Zagorje ob Savi, 1410 Slovenia Attention: Janez Gajski The products listed below
More informationOperating Instructions
Operating Instructions MSi-JM0100-USB R. STAHL HMI Systems GmbH Adolf-Grimme-Allee 8 D 50829 Köln Operating Instructions Version: 01.00.03 Issue date: 29.06.2017 Disclaimer Disclaimer Publisher and copyright
More informationInspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN
Inspection Light LED Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3 Conformity
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60079-0 Edition 3.1 2000-06 Edition 3:1998 consolidated with amendment 1:2000 Electrical apparatus for explosive gas atmospheres Part 0: General requirements IEC 2000 Copyright
More informationCertification Supplement Manual
PROCESS ANALYSERS SERVOTOUGH Oxy Gas Analyser Certification Supplement Manual Part Number: 01910008B Revision: 9 Language: UK English This page intentionally blank SERVOTOUGH Oxy Certification Supplement
More informationREGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC
EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or
More informationCertificate of Conformity
Applicant: Mine Safety Appliances Co. (Instrument Division) 1000 Cranberry Woods Drive Cranberry Township PA 16066 5207 United States of America Electrical Apparatus: Altair Portable Single Gas Detector
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Accessories BF 12 Mounting flange, 12 mm Technical Data specifications Switching element function NAMUR, NO Rated operating distance s n 4 mm Installation non-flush
More informationDrive systems for the chemical, oil and gas industry. Electric drives and systems
Drive systems for the chemical, oil and gas industry Electric drives and systems 2 VEM drive systems for the chemical, oil and gas industry VEM drive systems for the chemical, oil and gas industry 3 VEM
More informationIECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements
ExTR Reference Number...: ExTR Free Reference Number...: 223531 Compiled by + signature (ExTL)...: Reviewed by + signature (ExTL)...: NO/NEM/ExTR12.0018/00 Stig André Norheim Arne Hortman Date of issue...:
More informationDräger Polytron 5700 IR Detection of flammable gases and vapours
Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive
More informationCertificate of Compliance
FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The
More informationProduct manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands
Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these instructions
More informationMultiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55
www.stahl.de > Pre-wi ready-to-use multi-signalling unit > Corrosion resistant > Suitable for offshore / onshore harsh environments > Incorporates the FX15 GRP beacon YA90 for visual audible notification
More informationINERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)
FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries
More informationEU Declaration of Conformity EMC Directive 2014/30/EU, ATEX Directive 2014/34/EU, PED Directive 2014/68/EU No: MMI SE
We, EU Declaration of Conformity EMC Directive 2014/30/EU, ATEX Directive 2014/34/EU, PED Directive 2014/68/EU No: MMI-0047-0SE Micro Motion, Inc. 7070 Winchester Circle Boulder, CO, 80301 USA EMERSON
More informationUser s Manual YTA610 and YTA710 NEPSI Certification
User s Manual YTA60 and YTA70 NEPSI Certification [Option code: /NS, /NS5 and /NF] st Edition . INTRODUCTION Thank you for purchasing the YTA60 and YTA70 Temperature transmitters. This manual contains
More informationUncertified Translation Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (1) EC Type Examination Certificate (2) Equipment and Protective Systems for Use in Hazardous Locations - Directive
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT
More informationIntegrated Solutions Low Voltage Systems
Integrated Solutions Low Voltage Systems 612 Contents Energy Distribution Overview Module Technology 8146 614 Overview Flameproof Enclosures 8220 614 Overview Flameproof Enclosures 8261 614 Overview CUBEx
More informationINTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME)
INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME) To: Members of the Management Committee ExMC Introductory
More informationHazardous Areas - EXPLOSIONPROOF SOLENOIDS
Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas
More informationCertificate of Compliance
FF02 Certificate of Compliance Certificate: 70068210 Issued to: Cascade Technologies Ltd Glendevon House, Castle Business Park, Stirling, Scotland. UNITED KINGDOM FK9 4TZ Attention: Mr M Douglas. The products
More informationOperating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
More informationExp, pressurized systems
Exp, pressurized systems ATEX approved Principle, requirements and recommendation Exp, explosion protected systems The principle of a pressurized apparatus The entry of a surrounding atmosphere into the
More informationINSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres
INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG05D-SIL is a flameproof beacon which is certified
More informationElectrical Installations Design, Selection, Erection and Inspection
IECEx International Conference 2018 Jakarta, Indonesia Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2018 Jakarta, Indonesia Peter Thurnherr thuba Ltd.,
More informationARRAN LED LED FLOODLIGHT. Standard Specification. Features
ARRAN LED LED FLOODLIGHT The Arran LED floodlight range is low energy with an instant on output and up to 130,000 maintenance free hours. Specifically designed for applications where moisture, dirt or
More informationDSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor
Product ID Type # Product # Drawing # DSF 1210.00 SHV Ex-atex (2m) 374Z-05066 110428F1 DSF 1210.00 SHV Ex-atex (5m) 374Z-05176 110428F1 DSF 1210.00 SHV Ex-atex (10m) 374Z-05590 110428F1 DSF 1410.00 SHV
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm
More informationSurvey of electrical equipment installed in hazardous areas on tankers
(June 2015) Survey of electrical equipment installed in hazardous areas on tankers 1. Application The recommendations in this document apply for survey of electrical installation in hazardous areas on
More informationIllumination unit For sight glass level indicator Model LGI
Level Illumination unit For sight glass level indicator Model LGI WIKA data sheet LM 33.02 for further approvals see page 2 Applications Better identification of liquid and gaseous phase Direct indication
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBG15E and BExBG10E Flameproof / Increased Safety Xenon Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG15E and BExBG10E beacons are flameproof
More informationDTS Light fittings for explosive atmospheres
DTS Light fittings for explosive atmospheres For all zones and industrial applications LIGHT FITTINGS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones and industrial applications Tubular glass light
More informationINSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon
INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing
More informationAS/NZS :2016. Explosive atmospheres AS/NZS :2016. Part 7: Equipment protection by increased safety e. Australian/New Zealand Standard
AS/NZS 60079.7:2016 (IEC 60079-7, Ed 5.0:2015, IDT) Australian/New Zealand Standard Explosive atmospheres Part 7: Equipment protection by increased safety e Superseding AS/NZS 60079.7:2006 AS/NZS 60079.7:2016
More informationExplosion Proof Manual Call Points Series MCP
> Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied
More informationTECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:
Page 1 of 9 TECHNICL MNUL EXPLOSION PROOF STTUS LIGHT / LMP TEX Marking: Code: II 2GD EPL Gb, Db Ex d IIC T4/T5/T6 IP66 Ex tb IIIC TXXX C Marking details: Please note that every care has been taken to
More informationXLFE-4/1. Borosilicate glass globe
XLFE-4/1 Borosilicate glass globe - Zone 1, 2, 21, 22 - Obstruction warnings - LOW INTENSITY LED technology - Lamp lifespan more than 10 years - Complies with ICAO, FAA Painted aluminium body Ex e terminal
More informationmanual addendum DELPHI Ex
manual addendum DELPHI Ex II 2G Ex eb IIC T4 Gb II 2D Ex tb IIIC T135 C IP65 Db Tamb=-20 +40 C Reference list: Norm (last issue) Title Dir. 2014/34/UE EN 60079-31 EN60079-0 EN60079-7 Equipment and Protective
More information