DigiTrace NGC-family

Size: px
Start display at page:

Download "DigiTrace NGC-family"

Transcription

1 DigiTrace NGC-family The world beyond the MoniTrace 200N Robert Kuipers Electronics Marketing Manager Ken Wilson Industrial Sales Manager Peter Sirs UK/Nordics Regional Sales Manager Bruno Guinand Business Development Manager ( (Kashagan Project) DigiTrace NGC-20

2 Tyco Thermal Controls.. 2

3 Major Global Service Centres, Local Response Edmonton,C A Chicago,USA Amstelveen, NL Washington, UK Mudersbach, DE Houston,USA Philadelphia, USA Shanghai CN Tyco Thermal Controls 2000 Employees Worldwide 50 Locations 6 Manufacturing Facilities 9 Major Service Centers Mumbai IN 3

4 Trends in control and monitoring systems for industrial heat-tracing applications Increased importance of control and monitoring Safety requirements Less plant personnel Narrower temperature range for increased production quality and yields Lower operating and maintenance cost leading to enhanced requirements for Centralized access to critical information on heat-tracing system status Functionality specific to requirements of heat-tracing installations Data for analysis of trends and simplified fault finding 4

5 Why Do We Need Control Constant Wattage Constant Wattage heating cable Max. Heat loss (min ambient) Watts/M Min. Heat loss (max ambient) Pipe temperature, C 5

6 Why Do We Need Control Constant Wattage Constant Wattage heating cable Max. Heat loss (min ambient) Watts/M Min. Heat loss (max ambient) Line ID 10 Pipe Insulation diameter Thickness 5 Heater Catalog No Maintain Temp. Min. Ambient Temp. Min. Controlled Temperature Max. Ambient Temp. Max. Controlled Temperature in mm C C C C C H2O line 5 C FHT2-CT H2O line 70 C FHT2-CT Pipe temperature, C Steam line 120 C FHT2-CT

7 Why Do We Need Control Self Regulating Power output Self- Regulating heating cable Max. Heat loss (min ambient) Watts/M Min. Heat loss (max ambient) Pipe temperature, C 7

8 Why Do We Need Control Self Regulating Power output Self- Regulating heating cable Max. Heat loss (min ambient) Line ID Watts/M 15 Pipe temperature, C Min. Heat loss (max ambient) Pipe Insulation Min. Min. Max. Max. 10 Nominal Thickness Heater Maintain Ambient Controlled Ambient Controlled Dia (Inner) Catalog No Temp. Temp. Temperature Temp. Temperature 5 in mm C C C C C H2O line 5 C BTV2-CT H2O line 70 C QTVR2-CT Steam line 120 C KTV2-CT

9 Self Regulating with Thermostatic Temperature Control Self- Regulating heating cable SET-POINT Watts/M Heat loss (min ambient) Heat loss (max ambient) Pipe temperature, C 9

10 Introduction to PASC control (Proportional Ambient Sensing Control) Heat Loss = k A T insulation pipe size fluid temp ambient temperature We only need to sense the ambient temperature to know how to control the pipe temperature 10

11 Proportional Ambient Sensing Control: PASC Thermostat Set point (Pipe temp) OFF ON OFF 100% Time Duty Cycle (ON /OFF ratio) 0 T minimum T ambient T maintain Ambient Temperature 11

12 Practical example: Ambient Control Freeze protection system controlled by an ambient sensing thermostat. 100 % 10W/m Power provided Power usage 0-30 C Ambient Temperature Tset (5 C) 12

13 Practical example: PASC Control Freeze protection system controlled using PASC 100 % 10W/m Power provided Power usage 0-30 C Ambient Temperature Tset (5 C) 13

14 Savings on a yearly basis per 100 meter heat-tracing cable Line ID Insulation Thickness Maintain Temp. Heater Min. Ambient Temp. Min. Controlled Temperature Max. Ambient Temp. Max. Controlled Temperature Pipe Heat Loss Heater Output Control method mm C C C C C W/m W/m 3" H2O line 70 C SR XTV2-CT ,2 48,8 Uncontrolled 3" H2O line 70 C SR XTV2-CT ,2 48,8 PASC 3" H2O line 70 C SR XTV2-CT ,2 48,8 Line Sensing Assumption: Average Temperature 10 C Heat Loss At 10 C Power Output cable at 70 C Perfect energy balance 46% 22,6 W/m 48,8 W/m Watt kwhr per year Price kwhr Energy cost / year Savings Uncontrolled -> Cable activated 100% for 100m cable: , PASC -> Cable activated about 55% for 100m cable: , Line sensing for 100m cable: , * The smaller the overshoot at min. Ambient, the more savings PASC will bring

15 The Next Generation in Heat-Tracing Control Tyco Thermal Controls has made significant investments to further enhance its offering of control and monitoring solutions Today, we present the DigiTrace NGC family of enhanced control and monitoring for industrial heat-tracing systems 15

16 DigiTrace NGC A complete product family DigiTrace NGC-30: Central Monitoring and Central Control Multi-circuit control, monitoring and power distribution system Positioned for lowest total installed and operating cost DigiTrace NGC-20: Local Control and Central Monitoring Single circuit control, monitoring system with central monitoring Positioned for highest reliability and lowest total installed and Operating cost DigiTrace NGC-UIT: User Interface Terminal DigiTrace NGC-40: Enhanced multi-circuit control, monitoring and power distribution system Positioned for highest reliability and offering most features 16

17 DigiTrace NGC-30 Central Control Central Monitoring Enhanced control and monitoring for industrial heat-tracing systems

18 DigiTrace NGC-30 The advanced multi-circuit control, monitoring and power distribution system for heat-tracing applications Control and monitoring of up to 260* loops Capability to monitor temperature, groundfault currents, operating currents and voltages User interface terminal with touch screen technology Data logging for trending, fault finding and other analysis with DigiTrace supervisor *: System configuration dependent 23

19 DigiTrace NGC-30: Central Control Central Monitoring Distribution Panel: RCDs + Control 1 power cable per circuit 1 pair of wire for temperature sensor per circuit 24

20 DigiTrace NGC-30 system overview High level communication User interface DigiTrace NGC-components 25

21 DigiTrace NGC-30: User Interface Controllers Temperature measurement Configuration & monitoring Control Output Measure CRM & CRMS CTM PT100 panel or remotely panel field 26

22 Card rack modules exist in 2 types: Type 1: CRM for driving contactors Type 2: CRMS for driving solid state relays (SSR) 5 control loops on one board CRM Mechanical relay control On / Off, and PASC control CRMS Solid state relays for hazardous locations Additional features: Proportional Power-limiting Soft start / staggered start Alarm conditions Low / high temperature RTD failure Communications failure Ground-fault Low / high current Set independently for each loop 27

23 Ground fault and current measurement Via a current transformer the following parameters are measured: Net current loss in EHT system Ground Fault Total current to field Up to 60 A calibrated (100 A measured) 28

24 Ground fault measurement / current measurement setup Ground fault and current measurement setup screens on user interface terminal 29

25 Automatic self-test function Features Configurable self-test function Benefit: The heat-tracing system integrity is continuously monitored Malfunctions are reported to user via clear messages No surprises when you don t need them 30

26 DigiTrace NGC-30 network architecture Connection to DCS Ethernet RS-485 RS-232 Protocol ModBus 31

27 DigiTrace NGC-30 panels supplied as complete systems from small to large Last year more than 70 systems in Europe with more than 5000 EHT circuits 32

28 DigiTrace NGC-30 Central control of heat-tracing systems DigiTrace NGC-30 - a central overview of the heat-tracing system integrity Ease of use by colour touch screen technology DigiTrace Supervisory software Access to all information simplifies maintenance Data logging, trending, reports, drawings All heat-tracing control systems in one application Almost unlimited number of circuits... from any location in the world Enhanced control and monitoring for heat-tracing Monitoring of ground fault current helps to identify and locate water ingress or mechanical damage Automatic heat-trace system integrity checks Distributed architecture reduces total installed cost and many more features 33

29 DigiTrace NGC-20 Local Control Central Monitoring Enhanced Control and Monitoring system for Industrial Heat-Tracing applications DigiTrace NGC-20

30 DigiTrace NGC-20 System overview Local control Central Monitoring High level communication User interface DigiTrace NGC-20 controllers Smart Thermostat in the field 35

31 DigiTrace NGC-20: Local Control Central Monitoring Reduction of cabling and simplifies panel design Simplified Panel design Power cabling reduction No RTD wiring 36

32 Display on DigiTrace NGC-20 for direct indication Feature: Local display Benefit: Direct indication of temperature and alarms 37

33 Control and Monitoring Assistant for full accessibility in field Feature: User interface through portable handheld programming device Benefit: Hand held device offering a means of monitoring the electrical heat-tracing system in the field without opening the control unit 38

34 Control and Monitoring Assistant for full accessibility in field DigiTrace NGC-20 fully configurable via handheld device All parameters available via easy-to-use displays Full monitoring and alarm capability 39

35 User interface terminal (UIT) The UIT Is a central element in the DigiTrace-NGC family Is used for monitoring and configuration purposes Is a panel mounted device Has colour display with touch screen functionality The UIT is used for: Configuration Monitoring Alarming of various DigiTrace products like the DigiTrace NGC-20! 40

36 DigiTrace NGC-20 : available with integrated Intelligent Safety Temperature Limiter DigiTrace NGC-20 controller available in 2 versions ATEX IEC Ex For worldwide coverage 1. DigiTrace NGC-20-C-E (Control unit): Hazardous area approved controller (zone 1, 2, 21 and 22) 2. DigiTrace NGC-20-CL-E (Control and Limiter Unit): Hazardous area approved controller (zone 1, 2, 21 and 22) including Intelligent Safety Temperature Limiter certified as SIL 2 device Separate temperature sensor input 42

37 When do we need a Intelligent Safety Temperature Limiter? A Safety Temperature Limiter is required when the heating application: Is installed in Zone 1 / Zone 21 With control limited design Prevents temperature of heating cable go above T-class when controller fails Nuisance tripping due to high process temperature conditions requires manual reset in the field DigiTrace NGC-20 limiter is intelligent : Will only trip when heat-tracing is energised Prevents unnecessary intervention for maintenance personnel 43

38 Load shedding / Start-up reduces high peak load demands heat tracing can show high inrush currents. To reduce these high current peaks, the start-up of connected units the can be shifted in time in 16 different groups of DigiTrace NGC-20 Load shedding during emergency operation Group 1 Group 2 Group 3 Group 16 Group.. Group 4 Flexible grouping 44

39 Hybrid switch Continues monitoring of controller switching Feature: Dedicated control electronics per heating circuit and high current capacity of 25 A with hybrid switch Switching of the contactor is continuously monitored Alarms will be raised when the contactor is not switching as requested Benefit: Highest reliability and long lifetime, even at elevated circuit loads by dedicated electronics and hybrid switch Maintenance continues informed about the reliability of the controller 45

40 Junction boxes reduction Feature: Locally installed (on pipe) Heating cable directly connected Benefit: Direct heater connections reduce the number of field junction boxes, lowering power cable costs and maintenance cost 46

41 Circuit integrity monitoring of Electrical Heat- Tracing via DigiTrace NGC-20 Feature: Monitoring of status information: 1. temperatures, 2. supply voltage, 3. Earth leakage and 4. operating current; with fully configurable alarms Benefit: 1. Permanent supervision of the integrity of the heat-tracing circuit. 2. Detailed problem reporting simplifies maintenance and increase personnel safety and now in more detail 47

42 DigiTrace NGC-20: continues monitoring ground fault / earth leakage current DigiTrace NGC-20 system monitors earth leakage current at ma level Information The controller provides alarm and trip settings for earth leakage The alarm set point is configurable. Range is between 10 ma and 200 ma Corrective action The controller provides earth leakage trip settings Range between 10 ma and 200 ma Alarm trip point < Trip set point < Breaker trip point Earth leakage warning can be enabled / disabled Earth leakage trip can be enabled / disabled 48

43 Setup Earth leakage Measurement with 1. Hand held 2. User Interface Terminal 3. DigiTrace Supervisor 49

44 Current measurement Voltage measurement for EHT diagnostics The Current Transformer inside the DigiTrace NGC-20 measures the total Current to the heat-tracing cable. Voltage is measured alarms raised when voltage swings occur Energy consumption (KWh) circuit integrity 50

45 Automatic self-test function Feature: Configurable self-test function Benefit: The heat-tracing system integrity is continuously monitored Malfunctions are reported to user via clear messages No surprises when you don t need them 51

46 DigiTrace NGC-20 brings benefits of Local Thermostat & Central Monitoring together 52

47 DigiTrace NGC-20 Local Control Central Monitoring TTC World November

48 DigiTrace NGC-20 Summary Local Control Central Monitoring leads to considerable cost saving 1. Reduction of Total Installation Cost (TIC) Via reduction of cabling and simplified panel design 2. Reduction of Total Operation Cost (TOC) By informing Maintenance personnel of Heat-Tracing specific information like Earth Leakage currents, Load Current, Voltage and Power usage and system integrity check results Via Local display, Hand held device, User Interface Terminal and DigiTrace Supervisor ATEX approved SIL 2 device 54

49 DigiTrace NGC-40 Product Overview

50 DigiTrace NGC-40: Central control with central monitoring with full flexibility DigiTrace NGC-40 inherits strong features and benefits from DigiTrace NGC-20 and DigiTrace NGC-30 + = Designed for highest reliability and customer requirements 56

51 DigiTrace NGC-40: Completing the story DigiTrace NGC-40: full flexibility complementing your requirements Single CPU per circuit offering highest reliability and flexibility Modules plug and play DIN rail mountable for flexible and optimized panel design Wiring is minimized by using CAN-based network 57

52 DigiTrace NGC-40 controller building blocks The DigiTrace NGC-40 system contains 5 different control components 1. Communications Bridge Module DigiTrace NGC-40-BRIDGE 2. Control Module DigiTrace NGC-40-HTC (single phase) DigiTrace NGC-40-HTC3 (3-phase) 3. I/O Module DigiTrace NGC-40-IO 4. Safety Temperature Limiter Module DigiTrace NGC-40-SLIM 5. Power Transfer Module DigiTrace NGC-40-PTM 58

53 DigiTrace NGC-40: Central Control & Monitoring with single CPU per circuit Advanced panel mounted multi-circuit control, monitoring and power distribution system for heat-tracing applications Each circuits is controlled by individual independent controller Capability to monitor temperature, groundfault currents, operating currents and voltages Digital input to override heat-tracing control output Power and current clamping to reduce inrush currents 1 phase and 3 phase controllers SIL 2 Safety Temperature limiter 15 User interface terminal with touch screen technology Data logging for trending, fault finding and other analysis with DigiTrace supervisor 59

54 DigiTrace NGC-40 Control Modules Covering single phase and three phase systems NGC-40-HTC Single phase controller Monitors GF and load current NGC-40-HTC3 Three phase controller Monitors current of each phase Monitors GF Loads up to 60A Current and Ground Fault measurement inside module 60

55 DigiTrace NGC-40 Control Module Temperature and Logic input driven Direct PT100 RTD Temperature input to the Control Module Digital input allowing remote alarm and heat-tracing Force-ON and Force-OFF functions 61

56 Control Module and Solid State Relays bringing Enhanced features & benefits for your heat-tracing Feature: Benefit: High switching capability For accurate temperature control Feature: Benefit: Current and Power limitation Prevent high inrush currents and control heat-tracing power output 62

57 Load shedding reduces high peak load demands Group 1 Group 2 Group 3 Group 4 Group 6 Group 5 Group 8 Group 5 Group 7 Group 5 Group 6 63

58 Automatic self-test function Feature: Configurable self-test function Benefit: The heat-tracing system integrity is continuously monitored Malfunctions are reported to user via clear messages No surprises when you don t need them 64

59 DigiTrace NGC-40-IO Module Providing flexible configuration possibilities Module offers: Four temperature sensor inputs One multi-purpose dry-contact input One Form-C output relay 65

60 DigiTrace NGC-40-SLIM Safety Temperature Limiter Module Independent device applications requiring high temperature safety lockout Up to 3 sensors for 3 phase systems! Output controls an independent contactor Intelligent limiter SIL2 certified: Functional safety as per IEC

61 DigiTrace NGC-40 Bridge Connecting control to the User Interface Connecting the DigiTrace NGC-40 control to User Interface Terminal (UIT) DigiTrace Supervisor Software (DTS) DCS system (2011) Communication via: LAN RS-232 RS

62 Fully Compatible NGC Control System 68

63 DigiTrace Supervisor Bringing your heat-tracing information at the right spot at the right time

64 DigiTrace Supervisor The DigiTrace Supervisor (DTS) is a heat-tracing controller configuration and monitoring software package. It brings the heat-tracing control and monitoring facilities into the control room at the desk of the maintenance engineer or wherever wanted on the world 70

65 All comes together in the DigiTrace Supervisory Software Central access via software DigiTrace Supervisor Configuration and monitoring of all parameters of the entire installation (temperatures, alarms etc.) Client-server architecture Multi-access from locations wherever desired MS SQL server, enterprise class system Data logging for trending, fault finding and other analysis leading into predictive maintenance Less paper by integrating documentation and drawings into Supervisory Software 71

66 DigiTrace Supervisor is based on a client-server architecture SLAVE SERVER #1 NGC-20 NGC-20 Local engineer SLAVE SERVER #2 NGC-30 NGC-20 NGC-30 Porvoo Master Server NGC-30 SLAVE SERVER #3 NGC-40 Tyco Thermal Controls Service Team LAN/WAN NGC-40 NGC-40 72

67 DigiTrace Supervisor Configuration and monitoring DigiTrace Supervisor offers the following features: A graphical user interface for DigiTrace communication and controller products. A fully integrated alarm & event monitoring system with the ability to acknowledge and clear alarms as required. 73

68 DigiTrace Supervisor Configuration and monitoring DigiTrace Supervisor includes the following features (continued): Group displays for monitoring multiple controllers at the same time General and personal display settings possible 74

69 DigiTrace Supervisor Trending DigiTrace Supervisor includes the following features (continued): Logging & trending 75

70 DigiTrace Supervisor Batch, Recipe DigiTrace Supervisor includes the following features (continued): Batch & recipe processing, Scheduled events, Plant reference model for structuring controller on a logical way 76

71 DigiTrace Supervisor Reporting Reporting Alarms Configuration Users Location Communication Documentation link to device configuration and monitoring utilities 77

72 Scaleable architecture Three system sizes: 1. Single user/server PC (small systems) 2. Single server, multiple users (medium sized systems) 3. Multiple servers, multiple users (large systems - Enterprise) 78

73 DigiTrace Supervisor architecture Single server / up to 4 users (medium sized systems) Network Maintenance Engineer Operations Master Server NGC NGC NGC Remote Support Internet via VPN 79

74 Project Example Support at 2000 km distance System in South of Spain Local access via User Interface Terminal Engineer 500 km away in Madrid Tyco support from Belgium 80

75 In Summary

76 We raise the maintenance level to a more required level with the DigiTrace NGC-family Maintenance is classified in four categories: 1. Feedback Monitor its condition and replace it just before it fails. 2. Predictive Replace it one standard deviation before it statistically fails. 3. Preventive Oil it, and it will last longer. 4. Reactive If it breaks, fix it. With optimized DigiTrace NGC-20, DigiTrace NGC-30 & DigiTrace NGC-40 mix to minimize Total Installation Cost (TIC) Total Operation Cost (TOC) 82

77 DigiTrace NGC A complete product family DigiTrace NGC-30: Multi-circuit control, monitoring and power distribution system Offers lowest total installed cost DigiTrace NGC-20: Single circuit control, monitoring system with central monitoring Offers highest reliability and lowest total installed cost User Interface Terminal DigiTrace NGC-40: Enhanced multi-circuit control, monitoring and power distribution system Offers highest reliability and offering most features 83

78 Q & A - Additional general trace heating discussions Vendor recommendations on temperature control on frost lines in cold ambient temperature designs Vendor recommendation on start-up temperature for circuits Vendor experience of designing against hydrate formation Ability of water lines down to ½ to withstand 1 hour power outage without ice formation Vendor suggestions for early estimate of FFD trace heating load based on P&IDs and plot plans Reference list and/or brief summary of projects of similar scope and in similar environmental conditions Summary of experience in Kazakhstan with mention of lessons learnt on compliance with local regulations, logistics, installation etc 84

79 THANK YOU FOR YOUR ATTENTION ANY QUESTIONS???

NGC-20 LOCAL CONTROL CENTRAL MONITORING

NGC-20 LOCAL CONTROL CENTRAL MONITORING LOCAL CONTROL CENTRAL MONITORING NVENT RAYCHEM THE RAYCHEM IS A FIELD-MOUNTED ELECTRONIC TEMPERATURE CONTROL UNIT PROVIDING LOCAL CONTROL AND CENTRAL MONITORING CAPABILITIES FOR INDUSTRIAL HEAT-TRACING

More information

RAYCHEM NGC-30 COMPONENTS

RAYCHEM NGC-30 COMPONENTS PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM PRODUCT OVERVIEW CABLE DUCT Card Rack Modules TERMINAL STRIP PLINTH MAIN SWITCH 800 mm USER INTERFACE

More information

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM Card Rack Modules CABLE DUCT MAIN SWITCH 800 mm USER INTERFACE TERMINAL PRODUCT OVERVIEW The nvent

More information

920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS).

920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS). Product overview The DigiTrace 920 is a compact, full-featured, microprocessor-based, multipoint heat-trace controller. The 920 provides control and monitoring of two independent electrical heat-tracing

More information

HTC-915-CONT. Heat-Trace Control system

HTC-915-CONT. Heat-Trace Control system Heat-Trace Control system Product overview The Raychem HTC-915 system is a compact, full-featured microprocessor-based single-point heat-trace controller. The HTC-915-CONT provides control and monitoring

More information

NGC-40 Advanced Heat-Tracing Control System

NGC-40 Advanced Heat-Tracing Control System NGC-40 Advanced Heat-Tracing Control System Local configuration and monitoring with Raychem Touch 1500 touch screen display Heat-tracing system NGC-40 system Remote configuration and monitoring with Raychem

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint

More information

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview C910-485 SINGLE-POINT HEAT-TRACING CONTROL SYSTEM product overview ALARM SHIFT TEST C910 SERIES MONITOR CONFIG BACK ENTER PROGRAMMABLE SINGLE POINT HEAT-TRACING CONTROLLER STATUS ALARM OUTPUT The DigiTrace

More information

Dual-point heat-tracing control system

Dual-point heat-tracing control system Dual-point heat-tracing control system 920*E4FWL*SIS302*SS3102 shown Product overview The Raychem 920 is a compact, full-featured, microprocessor-based, dual-point heat-tracing control system. The 920

More information

C910 Series. Single-point heat-tracing control system

C910 Series. Single-point heat-tracing control system 1. Pipe Freeze Protection and Flow Maintenance Single-point heat-tracing control system 2. Roof and Gutter De-Icing Product overview The DigiTrace C910 is a compact, fullfeatured, microprocessor-based,

More information

HTC-915 Installation & operating manual

HTC-915 Installation & operating manual HTC-915 Installation & operating manual 915 SERIES PE N L To external alarm annunciater / DCS or PLC input Max 3A 250V CT input To external alarm annunciater / DCS or PLC input Max 3A 250V 21 20 19 18

More information

910 Series Single-point heat-tracing control system

910 Series Single-point heat-tracing control system Single-point heat-tracing control system 910*E1FWL*SSR2 Product overview The Raychem 910 is a compact, full-featured, microprocessor-based, single-point heat-tracing control system. The 910 provides control

More information

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM APPLICATION OVERVIEW Control and monitoring systems play an essential role in heat tracing applications which range from freeze protecting water lines to

More information

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW SHIFT TEST SHIFT C910 SERIES ALARM MONITOR CONFIG BACK ENTER PROGRAMMABLE SINGLE POINT HEAT-TRACING CONTROLLER HEAT-TRACING CONTROLLER STATUS ALARM

More information

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated) CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated) Typical system for snow melting of pavers, concrete and asphalt surfaces with temperature and moisture sensing control,

More information

NGC-20-C-E and NGC-20-CL-E

NGC-20-C-E and NGC-20-CL-E Self-regulating Field-mountedheating cable Electronic heat-tracing control unit Product overview The DigiTrace NGC-20 is an electronic heat-tracing control unit featuring the benefits of local control

More information

ACCS-30. Multipoint commercial heat-tracing control system

ACCS-30. Multipoint commercial heat-tracing control system Multipoint commercial heat-tracing control system Product Overview The DigiTrace ACCS-30 is a multipoint electronic control and monitoring system for heat-tracing used in commercial freeze protection and

More information

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM APPLICATION OVERVIEW Control and monitoring systems play an essential role in heat tracing applications which range from freeze protecting water lines to

More information

NGC-20-C-E and NGC-20-CL-E

NGC-20-C-E and NGC-20-CL-E Field-mounted Electronic heat-tracing control unit Product overview The DigiTrace NGC-20 is an electronic heat-tracing control unit featuring the benefits of local control and the capability for central

More information

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1 NGC-40 Bridge Overview Raychem-AR-H58862-NGC40BridgeOV-EN-1805 nvent.com 1 Table of Contents 1. NGC-40 Overview... 9 1.1 Example NGC-40 System... 10 2. Legal stuff... 11 3. Protocols... 12 3.1 Data es...

More information

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS Firmware versions up to V2.0.X INDUSTRIAL HEAT TRACING SOLUTIONS EN-RaychemNGCUIT2Protocol-IM-H57880 06/15 1/32 Contents Section I Introduction

More information

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM 2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40

More information

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines System for flow maintenance of above ground greasy waste disposal lines with line sensing control,

More information

Heating Cable. Description

Heating Cable. Description ITLS Base Panel 10 VGA Touch Screen HMI 40 Amps/Loop @ 100 480 VAC 6 Loops to 72 Loops NEMA 4 or NEMA 4X Enclosure SCR Control Integral Circuit Panel with Circuit Breakers Optional Main Disconnect Soft

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel from hazardous gases in

More information

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System SHIFT TEST BACK ENTER C910 SERIES STATUS OUTPUT ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM ACS-30 System MONITOR CONFIG POWER CONTROL MODULE ACCS-PCM-5 PROGRAMMABLE SINGLE POINT HEAT-TRACING CONTROLLER

More information

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines System for flow maintenance of aboveground fuel oil lines with Proportional Ambient Sensing Control (PASC),

More information

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated) CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated) System for preventing frost heave in freezers, cold rooms and ice arenas with temperature control, monitoring,

More information

TRACENET TM TN SERIES

TRACENET TM TN SERIES TRACENET TM TN SERIES CONTROL AND MONITORING SYSTEM INTRODUCTION Heat trace has become increasingly important for efficient and reliable operation of industrial process plants. This is true for both freeze

More information

Supervisor Standard Edition

Supervisor Standard Edition Supervisor Standard Edition Installation Manual Heat-Tracing Controller Configuration and Monitoring Software INSTALL-119 (Europe) 1 / 18 Contents Section 1 Introduction...3 1.1 Welcome...3 1.2 Vital Information...3

More information

NGC-20-C-E and NGC-20-CL-E

NGC-20-C-E and NGC-20-CL-E Field-mounted Electronic heat-tracing control unit Product overview The aychem NGC-20 is an electronic heat-tracing control unit featuring the benefits of local control and the capability for central monitoring.

More information

TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE TRACENET TM GENESIS APPLICATION OVERVIEW Control and monitoring systems can play an essential role in heat tracing applications which

More information

User s Manual. YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters. Manual Change No

User s Manual. YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters. Manual Change No User s Manual YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters Manual Change No. 16-045 Please use this manual change for the manuals listed below. 1. Applicable manuals, revised item, revised

More information

Dependable Solutions for Gas Detection

Dependable Solutions for Gas Detection Dependable Solutions for Gas Detection Combustibles/Flammables Standard & Exotic Toxics Oxygen Enrichment/Deficiency Introduction to Sensidyne Established in 1983 - acquired by Schauenburg GmbH in April

More information

Technical Databook for Industrial Heat-Tracing Systems 2006/2007

Technical Databook for Industrial Heat-Tracing Systems 2006/2007 R Technical Databook for Industrial Heat-Tracing Systems 2006/2007 www.tycothermal.com Tyco Thermal Controls brings together the knowledge, expertise, products and services of the leading brands in industrial

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Tel: +44 (0)8 9388 Email: info@ Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel

More information

Supervisor OPERATIONS MANUAL. Heat-Tracing Controller Configuration and Monitoring Software. Versions up to 2.7xx. INSTALL-118 (Europe)

Supervisor OPERATIONS MANUAL. Heat-Tracing Controller Configuration and Monitoring Software. Versions up to 2.7xx. INSTALL-118 (Europe) OPERATIONS MANUAL Supervisor Heat-Tracing Controller Configuration and Monitoring Software Versions up to 2.7xx INSTALL-118 (Europe) THERMAL MANAGEMENT Raychem-AR-H57576-SupervisorOperations-EN-1706 THERMAL

More information

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD SYSTEM CENTERS FRANCE Dräger Safety France S.A.S. 3c, Route de la Fédération 67025 Strasbourg Cedex Tel +33 388 40 76 76 Fax +33 388 40 76 67 P. R. CHINA Beijing Fortune Draeger Safety Equipment Co., Ltd.

More information

For Complete Fire and Gas Solutions

For Complete Fire and Gas Solutions Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable

More information

CONTROL AND MONITORIN

CONTROL AND MONITORIN CONTROL AND MONITORING CONTROL AND MONITORIN FOR PROCESS HEATING SYSTEMS FOR PROCESS HEATING SYSTEM CONTROL AND MONITORING FOR HEAT TRACING SYSTEMS THERMOSTATS AMBIENT SENSING Conventional ambient sensing

More information

DigiTrace T2000 Heat Trace Controller

DigiTrace T2000 Heat Trace Controller DigiTrace T2000 Heat Trace Controller INSTALLATION, OPERATING, AND MAINTENANCE MANUAL CM 2000 CM 2000+ AC 2000 AC 2000+ Control Module, Control Module, Alarm/Communications Interface Alarm/Communications

More information

TraceNet TM TCM2 CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

TraceNet TM TCM2 CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE TraceNet TM TCM2 CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE TraceNet TM TCM2 CONTROL AND MONITORING SYSTEM APPLICATION OVERVIEW Control and monitoring systems play an essential role in heat tracing

More information

SPECIFICATION GUIDELINE FROST PROTECTION FOR PIPES. Tender Specification. Engineering Specification for Pipe Frost Protection. Contents.

SPECIFICATION GUIDELINE FROST PROTECTION FOR PIPES. Tender Specification. Engineering Specification for Pipe Frost Protection. Contents. Tender Specification Package #: Trace Heating Engineering Specification for Pipe Frost Protection Contents Y24 Trace heating 2 Appendix A Schematics & Drawings 8 Prepared by: Authorised by: Issued

More information

For Raychem ACS-30 Controls Systems

For Raychem ACS-30 Controls Systems ACS-30 Protocol Interface Mapping For Raychem ACS-30 Controls Systems Firmware Version 5.05 THERMAL BUILDING SOLUTIONS EN-RaychemACS30-AR-H58324 03/16 Table of Content Section 1. Introduction... 3 1.1

More information

Fingertip control, optimum efficiency, total comfort and clear reporting. warmafloor.co.uk

Fingertip control, optimum efficiency, total comfort and clear reporting. warmafloor.co.uk Fingertip control, optimum efficiency, total comfort and clear reporting warmafloor.co.uk 1 Contents Intelligent control. 3 The key to efficiency Key system features 4 and benefits 7 Touchscreen 5 Alarms

More information

Substation Monitoring System

Substation Monitoring System Substation Monitoring System SF6 Gas Density Monitoring System Description Introduction As a result of recent European legislation on the control of greenhouse gasses, utilities and manufacturers alike

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable

More information

Domestic Hot Water Application manual

Domestic Hot Water Application manual Document Electrical Heating category Product name Domestic Hot Water Application manual 90% of the Legionella bacteria dies within the first 2 min at 60 C Let Danfoss do the work Index Danfoss Group is

More information

Specification for On-Line UPS Battery Monitoring and Data Management System

Specification for On-Line UPS Battery Monitoring and Data Management System 1 Scope This specification defines the minimum requirements for a predictive on-line Battery Monitoring BMDMS with test, analysis, and remote monitoring control capabilities. Unless noted otherwise, the

More information

Fire and Gas Monitoring Panel ST7-HV

Fire and Gas Monitoring Panel ST7-HV Fire and Gas Monitoring Panel ST7-HV INTRODUCTION TO THE ST7-HV SYSTEM The ST7-HV system is a programmable PLC suitable for safety and security installations with a high technological and economic content

More information

Advanced FireAlarm Panel 1-4Loop

Advanced FireAlarm Panel 1-4Loop Advanced FireAlarm Panel 1-4Loop Advanced Technologies Advanced Electronics Ltd IP Gateway Monitoring and interrogation via the internet Password protected multiple user permissions Event notification

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Minimum lighting control (base scope of work) shall include all corridors. The lighting in all the corridors shall be turned on (if not already on) if

More information

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification February 11, 2019 Master Panel Product Description The Master Panel shall provide lead/lag control and time based, automatic rotation of up to eight (8) boilers, when used in conjunction with LMV3 or LMV5

More information

Installation Guide. ECL Comfort 310, application A Table of Contents

Installation Guide. ECL Comfort 310, application A Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 5 2.1 Before you start.....................................................

More information

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac- Carriers Type Universal Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art

More information

CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems

CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems System for temperature maintenance of domestic hot water supply systems with energy efficient time based

More information

Industrial Grade Gas Detection Detecting The Difference

Industrial Grade Gas Detection Detecting The Difference detcon inc. Industrial Grade Gas Detection Detecting The Difference PO Box 8067 The Woodlands, TX 77387 888-367-4286 (toll free) 713-559-9200 281-292-2860 (fax) sales@detcon.com Catalog #CB-0409 www.detcon.com

More information

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR SAFETY MANUAL SIL 2 Certified Model FP-700 Combustible Hydrocarbon Gas Sensor Version 2.0 1 SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR This manual addresses the specific requirements and recommendations

More information

DELOMATIC 400, DM-400 HYDRO

DELOMATIC 400, DM-400 HYDRO Delomatic 400 HYDRO controller OPERATOR S MANUAL DELOMATIC 400, DM-400 HYDRO Functional description User interface Log books Alarm handling Document no.: 4189340880A SW version 1.0 or later Table of contents

More information

Operating Guide. ECL Comfort 210 / 296 / 310, application A247 / A Table of Contents

Operating Guide. ECL Comfort 210 / 296 / 310, application A247 / A Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 6 2.1 Before you start.....................................................

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with,,,, 0 and signal inputs Storage of the last state of inputs and sequence in the case

More information

Different types of Fire Alarm System

Different types of Fire Alarm System Different types of Fire Alarm System Conventional Fire System Generally comes with Zones. Each zone can have max 20 detectors. Addressable Fire Alarm System This comes in loops. Different manufacturer

More information

Touchpoint Pro Flexible Gas Control System

Touchpoint Pro Flexible Gas Control System Gas Detection Touchpoint Pro Flexible Gas Control System THE IDEAL SAFETY SYSTEM Honeywell s Touchpoint Pro makes gas control system design, installation, configuration and operation simple. Touchpoint

More information

Nov 08 PRODUCT SPECIFICATION SHEET

Nov 08 PRODUCT SPECIFICATION SHEET Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 Nov 08 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN

More information

L automazione al servizio della manutenzione nell industria di processo

L automazione al servizio della manutenzione nell industria di processo L automazione al servizio della manutenzione nell industria di processo Oscar Vigano Application Consultant CHEM-MED, RICH-MAC 24 September 2015 Process Control System Maintenance Automation Information

More information

Segment design & and Bus Diagnostics

Segment design & and Bus Diagnostics Segment design & and Bus Diagnostics Arasu Thanigai Business Development Manager Pepperl+Fuchs Pte Ltd, Singapore On behalf of FF End user Council Taiwan 1 Taiwan FF Seminar Part1 - Segment design & Verification

More information

GasGard 100 Control System

GasGard 100 Control System GasGard 100 Control System Because every life has a purpose... MSA Providing Fixed Gas and Flame Detection Solutions. It is critical for plant managers and personnel to have a proactive and diagnostic

More information

TD Series Temperature Transmitter with Local Display. One-piece sanitary construction 2-wire electronics High accuracy

TD Series Temperature Transmitter with Local Display. One-piece sanitary construction 2-wire electronics High accuracy TD Series Temperature Transmitter with Local Display One-piece sanitary construction 2-wire electronics High accuracy Temperature sensing technology Temperature transmitter for sanitary applications 2

More information

XL-Trace System Application and Design Guide

XL-Trace System Application and Design Guide R XL-Trace System Application and Design Guide Pipe Freeze Protection and Flow Maintenance for Commercial Construction Applications Pipe Freeze Protection and Flow Maintenance 1. Pipe Freeze Protection

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with 8, 16, 24, 32, 40 and 48 signal inputs Status retention of inputs and sequence in case

More information

Tyco Thermal Controls. Heat Management Solutions for Upstream Sector. Valentin ILIE Tyco Thermal Controls

Tyco Thermal Controls. Heat Management Solutions for Upstream Sector. Valentin ILIE Tyco Thermal Controls Tyco Thermal Controls Heat Management Solutions for Upstream Sector 2010 Tyco Thermal Controls Valentin ILIE Contents Tyco Thermal Controls Upstream Heat Management Solutions Overview Down Hole Heaters

More information

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option SM3000 Videographic Recorder User Guide (RTU) Communications Option ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow

More information

SUPREMATouch Modular Fire & Gas Detection System

SUPREMATouch Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Because every life has a purpose Class Leading Fire & Gas Detection Solutions MSA s permanent gas detection systems are relied upon by a huge number of

More information

Technical Databook for Industrial Heating Systems

Technical Databook for Industrial Heating Systems Technical Databook for Industrial Heating Systems R 2003 / 2004 Edition www.tycothermal.com Tyco Thermal Controls brings together the knowledge, expertise, products and services of the five leading brands

More information

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply   - Tel: Systems Index Systems - Systems Systems...1 -.16 General information Description...1 System description...2 Overview...3 Ordering details Arc monitor with detectors...4 Current sensing unit...5 Technical

More information

Temperature Solutions Line Card

Temperature Solutions Line Card Solutions September 2015 We re Your One Stop Temp Shop One simple model number is all it takes to order our complete, Ready-to-Install Assemblies. They include your choice of: Universal PC-Programmable,

More information

Heating Cable. Description

Heating Cable. Description ITASC1D2 Base Panel ITASC1D2-EXT Extender Panel Heat Tracing Control Panel Class I, Div. 2, 2-72 Circuits Class I, Division 2 Hazardous Environments - Groups A,B,C,D 7" or 10" Touch Screen HMI 40 Amps/Circuit

More information

NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions

NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions Description The NGC-UIT-ORD is a panel mounted display used in conjunction with other approved Raychem control and

More information

DigiTrace NGC-20. Local Control Central Monitoring

DigiTrace NGC-20. Local Control Central Monitoring DigiTrace Local Control Central Monitoring DigiTrace The DigiTrace is a field-mounted electronic temperature control unit providing local control and central monitoring capabilities for industrial heat-tracing

More information

SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW

SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL For three-phase heating cables Mounting brackets Nameplate HTC energized light Power on light Heater cycle timed control Heater (3R only)

More information

Instrumentation Products and Applications

Instrumentation Products and Applications 1 1/0 Instrumentation Products and Applications 1 Instrumentation Safety barriers I.S. Isolators - DIN rail mounting - Eurocards - Modules Remote I/O Operating and monitoring systems Instrumentation systems

More information

Danfoss gas detection unit Type GD Heavy Duty

Danfoss gas detection unit Type GD Heavy Duty Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

Building Automation Systems from Grantek: Going Beyond Compliance to Improve Operations

Building Automation Systems from Grantek: Going Beyond Compliance to Improve Operations Building Automation Systems from Grantek: Going Beyond Compliance to Improve Operations WWW.GRANTEK.COM 1 Overview Building automation systems (BAS) are necessary and ubiquitous in today s smart manufacturing

More information

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem XL-Trace fire sprinkler freeze protection system. For other applications

More information

When reliability is vital. Alemite Carbon Shield TM Systems deliver

When reliability is vital. Alemite Carbon Shield TM Systems deliver CATALOG 2 When reliability is vital. Alemite Carbon Shield TM Systems deliver Atomized Oil Lubrication system for rotating machinery bearings, gears and chains. Proven in refineries, petro-chem plants,

More information

Contamination Control for Electronic and Semiconductor Applications

Contamination Control for Electronic and Semiconductor Applications Contamination Control for Electronic and Semiconductor Applications CONTROLLED ENVIRONMENTS Contamination Control TSI Sets the Standard Performance Semiconductor, hard disk drive, and flat panel manufacturers

More information

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side s Frost detector for use on the air side QAF64.2-J QAF64.6-J With active capillary tube sensing element for acquiring the lowest temperature within a range of 0 15 C With startup function Operating voltage

More information

THERMAL MANAGEMENT SOLUTIONS

THERMAL MANAGEMENT SOLUTIONS Pipe Freeze Protection and Flow Maintenance ECW-GF, ECW-GF-DP Digital electronic controllers and remote display panel Fire Sprinkler System Freeze Protection ECW-GF with FTC-PSK pipe stand and power connection

More information

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management Reyrolle Protection Devices 7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management 7XG3120 - Arc Fault Monitor Relay The over-current caused by an arc is, due to its resistance, lower than the over-current

More information

Applications i.cas typical application is control of compressed air systems. It eliminates energy waste, provides state of the art compressor sequencing, load matching, independent user zones with isolation

More information

Altanium Temperature Controllers

Altanium Temperature Controllers Designed to provide the industry s most consistent part quality Benefits 2 to 254 zones of control Simple and intuitive operation Interchangeable cards and interfaces across the entire product line Active

More information

DigiTrace C910 Series Heat Trace Controller Installation, Operation, and Maintenance Manual

DigiTrace C910 Series Heat Trace Controller Installation, Operation, and Maintenance Manual DigiTrace C910 Series Heat Trace Controller Installation, Operation, and Maintenance Manual Firmware versions up to V3.2X Contents Contents... ii Section 1 Overview... 1 1.1 Introduction... 1 1.2 Product

More information

Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018

Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018 Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018 Before we start A Penny for Your Thoughts At the end of the session, share your feedback via

More information

SX65 and SX75. Electronic process controllers

SX65 and SX75. Electronic process controllers SX65 and SX75 Electronic process controllers A combination of simplicity and sophistication... The SX range of process controllers from Spirax Sarco has been designed after carefully considering both technical

More information

Fire Alarm Network Reference

Fire Alarm Network Reference Fire Alarm Network Reference Network Overview with Applications Reference Features Network communications among system fire alarm control panels provides: Support for up to 99 nodes per Network Loop to

More information

ORION-PL Poultry computer for cage houses

ORION-PL Poultry computer for cage houses ORION-PL Poultry computer for cage houses The ORION-PL is a versatile and user friendly climate and management computer and is used in sheds with laying hens. The ORION-PL can control / monitor each conceivable

More information

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS UNDERSTANDING, ACCELERATED TSI SETS THE STANDARD FOR PARTICLE COUNTING Performance Semiconductor, hard disk drive, and flat panel manufacturers

More information