Autronica Fire and Security AS ID:

Size: px
Start display at page:

Download "Autronica Fire and Security AS ID:"

Transcription

1 1 1

2 Autronica Fire and Security AS A leading innovator, manufacturer and supplier of fire & gas detection equipment Founded in 1957 in Trondheim, Norway Protecting life, environment and property 2

3 Fire & Gas Detection Challenges Building Fire Detection System 95% of Critical Faults caused by electronics faults, human mistakes, or manual testing 3

4 BREAK GLASS Tilpasningsenhet FIRE ALARM Interface unit Nr. No. AutroSafe Automatic Addressing Each detector has a unique ID, and therefore automatic addressing When powering up, the system will automatically find all units IDs, register and remember and simultaneously register each detectors place in the loop Built-in Short Circuit Isolators 100% Operational with Wiring Fault Specific Location of Fault Provided 1 ID IDENTITETSKORT Multi SENSOR Sensor MULTI NRR < < 246 DES KNUS GLASSET TRYKK HER PRESS HERE BN- 35 BRANNALARM

5 AutroSafe SelfVerify Power supply Automatically Tested Every 24 Hours Smoke detector Fault warning Fault signal Fire Alarm Fire Alarm Signal Operating STOP! All Loop Units SV- Communication- i control interface Alarmsignal SelfVerify stimulator ALARM! Detection chamber Test smoke 5

6 Fire & Gas Detection Challenges Building Fire Detection System 95% of Critical Faults caused by electronics faults, human mistakes, or manual testing Communication Failures Flame & Gas Detectors Between Engineering & Procurement Between Engineering & Maintenance/Operations Recognizing Need for Revising Procedures 6

7 AutroFlame X33AF Technology Multispectrum IR Maximum False Alarm Rejection Solar Resistance Single Detector for Multiple Fuels Automatic Optical Integrity (OI) Test Built-in lamps test all sensors every 60 seconds No external test lamp required 7

8 X33AF Cone of Vision Not tall Flame Detectors t See Equally Coverage Areas are different for each model & manufacturer Smaller coverage areas lead to a higher quantity of detectors required 8

9 AutroPoint HC200 Technology A diffusion-based, infrared combustible gas detector (point-ir) that provides continuous, fixed monitoring of flammable hydrocarbon gases from 0 to 100% Lower Explosive Limit (LEL) Methane (default), ethane, propane, butane, ethylene and propylene (100 flammable Hydrocarbon vapours) Calibration Not Required! 21 Years MTBF 9

10 AutroPath HC-600 Open Path Gas Detector meter Separation Redundant Xenon IR lamps Same detector model (spares) for entire range of separation distance 10

11 Acoustic Gas Leak Detector Stainless Steel 4-20mA w/ HART SIL-2 2Rated Range of 12-20m (at 58dB) Analyzes 24 discrete ultrasonic frequency bands Data Logging w/ Removable Storage 11

12 AutroTox Gas Detectors Local Display with Relay, Alarm, and Fault Outputs Combined with isolated 4-20mA H2S 0-20 ppm H2S 0-50 ppm 4-20 ma output with HART H2S ppm Nonintrusive Calibration CL ppm Fully Explosion-Proof Housing NH ppm 316SS or coated aluminum NH ppm H ppm Easy-to-Set Alarm Levels O2 0-25% by Vol Access to Alarm and Fault History CO ppm Multiple Conduit Access Points CO ppm SO ppm SO ppm 12

13 Fire & Gas Detection Challenges Building Fire Detection System 95% of Critical Faults caused by electronics faults, human mistakes, or manual testing Communication Failures Flame & Gas Detectors Between Engineering & Procurement Between Engineering & Maintenance/Operations Recognizing Need for Revising Procedures Industry Misconceptions SIL 13

14 What is SIL? Safety Integrity Level (SIL) is a measure of safety for a given protective function. Specifically, the extent to which the end user can expect the protective function to perform, and in the case of a failure, fail in a safe manner. This protective function is known as the Safety Instrumented Function (SIF). A Safety Instrumented System (SIS) is a collection of components (field devices and logic solver) that execute one or more SIFs

15 SIL Misconceptions SIL Applies to Individual Devices Connecting SIL Devices Creates a SIL Approved System Redundancy is Required to Meet a SIL Rating 15 15

16 Misconception: - SIL Applies to Individual Devices IEC states that a SIL number applies to a complete function (SIF), i.e. the field sensor, the logic solver and the final element. It is therefore incorrect to refer to any individual item or equipment having a safety integrity level. An individual component can be certified for use in a particular SIL application, but such a certificate constitutes only part of the verification effort, since the target SIL must be verified for the complete SIF. SIF Detector Loop driver module F&G alarm panel Output 16

17 Misconception: SIL Requires Redundancy SIL ratings do not require redundancy. SIL Ensures that a safety related system adequately performs the required safety functions under all stated conditions within a defined period of time. SIL assesses the risk reduction required for a tolerable level l of risk. Redundancy is used to raise the availability of unreliable equipment. How likely is it that the function in question will perform its assigned task when needed? d? 17 17

18 Autronica The Only Fire Detection System SIL 2 Approved by TUV Autronica is safe and reliable. SelfVerify function tests field devices and reports system as if newly installed every day. Autronica AutroSafe system s SIF & SIS have been tested and approved by third party TUV - World leader in SIL assessment. AutroSafe SIF SIL 2 Approved from Input to Output Sensor Loop driver module F&G alarm panel Output 18 18

19 Fire & Gas Detection Challenges Building Fire Detection System 95% of Critical Faults caused by electronics faults, human mistakes, or manual testing Communication Failures Flame & Gas Detectors Between Engineering & Procurement Between Engineering & Maintenance/Operations Recognizing Need for Revising Procedures Industry Misconceptions SIL Compliance with Different Worldwide Regulations 19

20 Autronica Always a Safe Choice Designed and approved according to international standards and regulations ISO 9001 EX certification Approval Certificates Available for Download IEC61508 SIL 2 NAN YANG 20

21 Fire & Gas Detection Challenges Building Fire Detection System 95% of Critical Faults caused by electronics faults, human mistakes, or manual testing Communication Failures Flame & Gas Detectors Between Engineering & Procurement Between Engineering & Maintenance/Operations Recognizing Need for Revising Procedures Industry Misconceptions SIL Compliance with Different Worldwide Regulations Communicating with PLC/DCS/ICSS/SIS/insert-your-own-initialism own initialism 21

22 AutroSafe Communication Safety PLC AutroSafe BS-420 / BC-420 panels Modbus RTU, Modbus TCP, and OPC {or AutroCom} AutroSafe panels have integrated t Modbus converters 22

23 AutroCom - direct link to DCS vendors ABB AC400 ABB AC800 (SIL2) Siemens S7 Kongsberg (SIL2) Emerson Delta V The Serial Port on the Multifunction Connection List can be used for one of these communication types: Serial VDR Serial ESPA Serial - MODBUS Master Serial - MODBUS Slave Serial - Autrocom: SERIAL SERIAL SLIDING WINDOW SERIAL SLIDING WINDOW HIGH INTEGRITY* (For example for SIL2 connections) Two TCP/IP ports on the main board (BSA-400) in different subnet, can be connected to switches with multiple ports, and can be used for up to six of these communication types: TCP - MODBUS Master TCP - MODBUS Slave TCP - Autrocom: TCP/IP TCP/IP HIGH INTEGRITY* (For example for SIL2 connections) TCP Web server with Secure LogOn and Automatically shutdown. For uploading and downloading software, logs, etc. 23

24 Truly Redundant Communication Architecture Safety PLC/DCS BS

25 AutroSafe IFG Architecture Overview 25

26 Thank You for Your Time Are There Any Questions 26 26

GAS DETECTORS. When every second counts

GAS DETECTORS. When every second counts GAS DETECTORS When every second counts PERFORMANCE AND SAFETY BEYOND COMPLIANCE We deliver rock-solid, performance-tested detectors for a wide variety of gas hazards, all with global approval. Our proven

More information

F&G detection system for LNG plants

F&G detection system for LNG plants LNG PLANT F&G detection system for LNG plants The historical safety record for the LNG industry is strong. Engineering, installation and lifetime use takes into account the well known hazards of such an

More information

System Design and Engineering AutroSafe Interactive Fire & Gas Detection System (IFG)

System Design and Engineering AutroSafe Interactive Fire & Gas Detection System (IFG) System Design and Engineering AutroSafe Interactive Fire & Gas Detection System (IFG) 116-P-SYSDEENGIN-IFG/XGB, Rev. A, 2015-08-14, Autronica Fire And Security AS COPYRIGHT This publication, or parts thereof,

More information

AUTROSAFE. An interactive fire detection system for larger vessels

AUTROSAFE. An interactive fire detection system for larger vessels AUTROSAFE An interactive fire detection system for larger vessels AUTROSAFE AutroSafe interactive fire detection system is designed for the toughest requirements and expands the possibilities of a fire

More information

AUTROSAFE 4 A new level in interactive fire detection systems

AUTROSAFE 4 A new level in interactive fire detection systems AUTROSAFE 4 A new level in interactive fire detection systems Autronica Fire and Security AS Protecting life, environment and property... Proven, reliable and now even better AutroSafe 4 the next generation

More information

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR SAFETY MANUAL SIL 2 Certified Model FP-700 Combustible Hydrocarbon Gas Sensor Version 2.0 1 SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR This manual addresses the specific requirements and recommendations

More information

Dräger Flame 2500 Flame Detection

Dräger Flame 2500 Flame Detection Dräger Flame 2500 Flame Detection Working in areas with combustible gases, vapours or materials requires fire/ flame detection as a life-saving necessity. The best solutions must combine state-of-the-art

More information

A New Standard of Excellence

A New Standard of Excellence A New Standard of Excellence PREVENTION IS SO EASY... LIVING THROUGH A DISASTER IS NOT The reliable identification of low combustion oxygen in a fired heater or boiler has always been critical to the effectiveness

More information

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance Combustible and Toxic Gas Detection Solutions Performance and Safety Beyond Compliance Reliable Solutions from Det-Tronics, Your Partner in Safety Trusted Response with the Utmost Confidence Our proven

More information

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance Combustible and Toxic Gas Detection Solutions Performance and Safety Beyond Compliance Reliable Solutions from Det-Tronics, Your Partner in Safety Trusted Response with the Utmost Confidence Our proven

More information

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors SAFETY MANUAL FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent

More information

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

SAFETY MANUAL. Multispectrum IR Flame Detector X3301 SAFETY MANUAL Multispectrum IR Flame Detector X3301 SAFETY-CERTIFIED MODEL X3301 MULTISPECTRUM INFRARED DETECTOR This manual addresses the specific requirements and recommendations applicable to the proper

More information

SIL 2. Ultima X Series Gas Monitors CERTIFIED

SIL 2. Ultima X Series Gas Monitors CERTIFIED Ultima X Series Gas Monitors 5 Now with SIL 2 CERTIFIED Products Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection

More information

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance IR4000 Point Infrared Combustible Gas Detection System The Reliable and Flexible Safety Solution That s Low Maintenance Multi-Point Gas Detection That s Fast Set-Up, Low Maintenance, Cost-Effective The

More information

AutroSafe interactive fire detection system AUTROSAFE. An interactive fire detection system for complex installations

AutroSafe interactive fire detection system AUTROSAFE. An interactive fire detection system for complex installations AutroSafe interactive fire detection system AUTROSAFE An interactive fire detection system for complex installations AUTROSAFE AutroSafe interactive fire detection system is designed to meet the toughest

More information

Industrial Grade Gas Detection

Industrial Grade Gas Detection Industrial Grade Gas Detection DETECTING THE... Difference Catalog #CB 0112 detcon inc. an company www.detcon.com Houston Odessa Shanghai Dammam Del Carmen Europe Company Profile ISO 9001: 2008 Certified

More information

FUNCTIONAL SAFETY MANUAL

FUNCTIONAL SAFETY MANUAL FUNCTIONAL SAFETY MANUAL UltraSonic EX-5 Ultrasonic Gas Leak Detector The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent

More information

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors Ultima X Series Gas Monitors Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection methods. HART Protocol is now

More information

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508 Open-Path Gas Detection System SAFEYE XENON 700 Hydrocarbons and ethylene detection Heated optics 10-year Warranty for the Xenon flash bulb SIL 2 according to IEC 61508 Certifications The Fixed Gas Detection

More information

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector FUNCTIONAL SAFETY MANUAL Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector The information and technical data disclosed in this document may be used and disseminated only for the purposes

More information

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions Because every life has a purpose PrimaX IR Gas Transmitter Every feature of the SIL 2 engineered PrimaX IR Gas Transmitter

More information

Instructions Infrared Hydrocarbon Gas Detector AutroPoint HC200

Instructions Infrared Hydrocarbon Gas Detector AutroPoint HC200 Instructions Infrared Hydrocarbon Gas Detector AutroPoint HC200 Instructions AutroPoint HC200, 116-P-HC200/IGB, rev. C, 2017-05-08, Autronica Fire and Security AS COPYRIGHT This publication, or parts thereof,

More information

Addressing Challenges in HIPPS Design and Implementation

Addressing Challenges in HIPPS Design and Implementation Addressing Challenges in HIPPS Design and Implementation Valve Manufacturer s Association Afton Coleman, CFSP March 11, 2016 Agenda SIS and SIL basics HIPPS Purpose Increased demand for HIPPS, why? The

More information

FIRE AND GAS LIFE EXPANSION AND MODIFICATION AUSTRALIA BROWNFIELDS CONFERENCE PERTH AUGUST 2014 GEIR SOLEM

FIRE AND GAS LIFE EXPANSION AND MODIFICATION AUSTRALIA BROWNFIELDS CONFERENCE PERTH AUGUST 2014 GEIR SOLEM FIRE AND GAS LIFE EXPANSION AND MODIFICATION AUSTRALIA BROWNFIELDS CONFERENCE PERTH AUGUST 2014 GEIR SOLEM 1 AUTRONICA FIRE AND SECURITY A leading innovator, manufacturer and supplier of fire safety equipment

More information

Model D12-IR. Digital Gas Transmitter...

Model D12-IR. Digital Gas Transmitter... Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact

More information

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System SAFETY MANUAL Open Path Hydrocarbon Gas Monitoring System The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically

More information

Industrial Grade Gas Detection Detecting The Difference

Industrial Grade Gas Detection Detecting The Difference detcon inc. Industrial Grade Gas Detection Detecting The Difference PO Box 8067 The Woodlands, TX 77387 888-367-4286 (toll free) 713-559-9200 281-292-2860 (fax) sales@detcon.com Catalog #CB-0409 www.detcon.com

More information

IEC61511 Standard Overview

IEC61511 Standard Overview IEC61511 Standard Overview Andre Kneisel Instrumentation Engineer Chevron C.T. Refinery SAFA Symposium 2011 August 5 th, 2011 Presentation Overview Provide some understanding of the key aspects of Functional

More information

Products and performance

Products and performance Products and performance February 26, 2016 GfG Instrumentation overview of fixed system products Slide 1 GfG Instrumentation, Inc. 1194 Oak Valley Drive, Suite 20, Ann Arbor, Michigan 48108 Toll free (USA

More information

Global Gas Detection and Monitoring Solutions

Global Gas Detection and Monitoring Solutions Global Gas Detection and Monitoring Solutions With over 100 years experience in specialized safety, fire and gas detection systems, we are The Fixed Gas Detection Experts. www.oldhamgas.com At Oldham,

More information

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL SAFETY MANUAL PointWatch Eclipse Infrared Hydrocarbon Gas Detector SIL 2 Certified Model PIRECL Safety Certified Model PIRECL PointWatch Eclipse IR Gas Detector This manual addresses the specific requirements

More information

For Complete Fire and Gas Solutions

For Complete Fire and Gas Solutions Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable

More information

Dräger Flame 2100 Flame Detection

Dräger Flame 2100 Flame Detection Dräger Flame 2100 Flame Detection Working in areas with combustible gases, vapors, or materials requires fire/ flame detection as a life-saving necessity. The best solutions must combine state-of-the-art

More information

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions!

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions! Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions! www.spectrex.net 2 SafEye Quasar 900 Series Open Path Gas Detector The

More information

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY Agenda 1 Challenges in the Process Industry International codes and standards F&G in an industrial Facility Honeywell s industrial F&G

More information

2015 Honeywell Users Group Europe, Middle East and Africa

2015 Honeywell Users Group Europe, Middle East and Africa 2015 Honeywell Users Group Europe, Middle East and Africa Safety System Lifecycle Support and Honeywell s capabilities in Industrial Fire & Gas Johan School, Honeywell (Product Manager Safety Systems)

More information

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors SAFETY MANUAL X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors SAFETY-CERTIFIED Flame DETECTORs This manual addresses the specific requirements and recommendations applicable to the proper

More information

Instructions Infrared Hydrocarbon Gas Detector AutroPoint HC300PL

Instructions Infrared Hydrocarbon Gas Detector AutroPoint HC300PL Instructions Infrared Hydrocarbon Gas Detector AutroPoint HC300PL 116-P-HC300PL/DGB, rev. A, 2010-08-03. DEC P/N 95-8587-1.1 COPYRIGHT This publication, or parts thereof, may not be reproduced in any form,

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Tel: +44 (0)8 9388 Email: info@ Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel

More information

User s Manual. YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters. Manual Change No

User s Manual. YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters. Manual Change No User s Manual YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters Manual Change No. 16-045 Please use this manual change for the manuals listed below. 1. Applicable manuals, revised item, revised

More information

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection. FIXED GAS DETECTION OLCT 700 Series OLCT 700/710 industrial gas detection sensors are a new generation of intelligent sensor modules that incorporate and integrate several leading edge improvements. &

More information

Recalibrate the way you look at gas detection

Recalibrate the way you look at gas detection Catalogue Gas detection solution Recalibrate the way you look at gas detection Next generation gas detection for industrial refrigeration The next generation of Danfoss gas detectors are based on a digital

More information

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control. Détecteur de gaz OLCT80 Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Disponible en version déportée, ADF ou de SI

More information

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions The Most Versatile Flame Detectors in the World Optical Flame Detection Solutions The Global Leader in Flame Detection Superior Performance and Reliability Flame detection is the very essence of the proud

More information

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device Featuring an ergonomic design and innovative infrared sensor technology, the Dräger X-am 5600 is the smallest gas detection instrument for the

More information

Danfoss gas detection unit Type GD Heavy Duty

Danfoss gas detection unit Type GD Heavy Duty Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx

More information

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES DET-TRONICS SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION Eagle Quantum Premier is a configurable, distributed, intelligent safety system providing flame

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

SUPREMATouch Modular Fire & Gas Detection System

SUPREMATouch Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Because every life has a purpose Class Leading Fire & Gas Detection Solutions MSA s permanent gas detection systems are relied upon by a huge number of

More information

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD SYSTEM CENTERS FRANCE Dräger Safety France S.A.S. 3c, Route de la Fédération 67025 Strasbourg Cedex Tel +33 388 40 76 76 Fax +33 388 40 76 67 P. R. CHINA Beijing Fortune Draeger Safety Equipment Co., Ltd.

More information

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions *** Technical data sheet TDS0149 LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions *** SIL1 MSH2-LS/HC/CO2 MSH2ia-LS/HC/CO2

More information

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications SAFETY MANUAL Intelligent Sensors for H 2 S Gas Applications The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically

More information

Flame Detection Jon Sarfas

Flame Detection Jon Sarfas Flame Detection Jon Sarfas Agenda Introduction Detection Principles FL4000H MSIR Flame Detector Flame Test Lamp Installation Best Practice Features & Benefits Applications Introduction Primary objectives:

More information

Integrating Fire and Gas Safety with Process Control Systems:

Integrating Fire and Gas Safety with Process Control Systems: WHITE PAPER Integrating Fire and Gas Safety with Process Control Systems: Why, What and How If a fire, smoke or gas leak is detected in an industrial facility, prescriptive actions must be taken by the

More information

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR 70086 The information in this doucment is applicable to sensors built in September, 2008 or later (Firmware 3.0) The information and technical

More information

Fire and Gas Monitoring Panel ST7-HV

Fire and Gas Monitoring Panel ST7-HV Fire and Gas Monitoring Panel ST7-HV INTRODUCTION TO THE ST7-HV SYSTEM The ST7-HV system is a programmable PLC suitable for safety and security installations with a high technological and economic content

More information

Case Study. INTEGRATING Fire & GAS SAFETY WITH PROCESS CONTROL SYSTEMS

Case Study. INTEGRATING Fire & GAS SAFETY WITH PROCESS CONTROL SYSTEMS INTEGRATING Fire & GAS SAFETY WITH PROCESS CONTROL SYSTEMS INTEGRATING Fire & GAS SAFETY WITH PROCESS CONTROL SYSTEMS If a fire, smoke or gas leak is detected in an industrial facility, prescriptive actions

More information

FM Approved Fire & Gas Detection System

FM Approved Fire & Gas Detection System H a z a r d W a t c h FM Approved Fire & Gas Detection System State of the Art Fire and Intelligent, Modular and Flexible The HazardWatch Integrated Fire and Gas Detection System from General Monitors

More information

Fire and Gas Detection and Mitigation Systems

Fire and Gas Detection and Mitigation Systems Fire and Gas Detection and Mitigation Systems Dr. Lawrence Beckman, PE, TÜV FSExp SafePlex Systems, Inc., Houston, Texas ABSTRACT Fire and Gas Detection systems are key components in the overall safety

More information

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring. Water Quality Labo- Soil/ Soil/ Sedi- Sam- & Air / Dust Toxic gases are present in a wide variety of industrial and civil installations and their detection and monitoring is crucial for the safe working

More information

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots 5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots GX-6000 5 Operating modes Normal Leak Check Inert Bar hole Snap Log Monitor up to

More information

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots 5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots CONFINED SPACE ENTRY Monitor LEL, O2, CO, and H2S Internal sample pump Pull samples

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Safety Instrumented Systems

Safety Instrumented Systems Safety Instrumented Systems What is a Safety Instrumented System? A Safety Instrumented System SIS is a new term used in standards like IEC 61511 or IEC 61508 for what used to be called Emergency Shutdown

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel from hazardous gases in

More information

Safety Instrumented Fire & Gas Systems

Safety Instrumented Fire & Gas Systems Safety Instrumented Fire & Gas Systems aesolutions Provides Full-Service Fire & Gas Engineering and Products The aesolutions FM-approved family of Fire & Gas safety systems ensures compliance with the

More information

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions The Most Versatile Flame Detectors in the World Optical Flame Detection Solutions The Global Leader in Flame Detection Superior Performance and Reliability Flame detection is the very essence of the proud

More information

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours Dräger Polytron Pulsar 2 Detection of flammable gases and vapours The Dräger Polytron Pulsar 2 is the latest infrared technology in open path gas detection. Equipped with all the same functions as the standard

More information

Dräger Flame 2500 (IR3) Flame Detection

Dräger Flame 2500 (IR3) Flame Detection Dräger Flame 2500 (IR3) Flame Detection With its triple IR sensor The Dräger Flame 2500 detects hydrocarbonbased fires even over greater distances. Moreover, it offers a high reliability against false

More information

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6 Digital Gas Transmitters with Auxiliary s & Control Specifications subject to change without notice. USA 181011 Page 1 of 5 DESCRIPTION Digital RS-485 communicating, addressable toxic and combustible gas

More information

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 8310 IR Detection of flammable gases and vapour Dräger Polytron 8310 IR Detection of flammable gases and vapour The Dräger Polytron 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700 We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP 0584389 LEL. METERS Open-path Gas Detection Concepts 40-meter path 7m wide cloud

More information

2013 Honeywell Users Group Europe, Middle East and Africa. Erik de Groot. Safety and Fire & Gas Solutions

2013 Honeywell Users Group Europe, Middle East and Africa. Erik de Groot. Safety and Fire & Gas Solutions 2013 Honeywell Users Group Europe, Middle East and Africa Erik de Groot Safety and Fire & Gas Solutions 1 Layered safety approach Emergency shutdown Burner management Fire and Gas 2 Out of the box Safety

More information

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS A Worldwide Manufacturer of Process Analyzers and Instrumentation RELIABILITY EXPERIENCE SOLUTIONS AMETEK Process Instruments is a worldwide

More information

SINGLE MONITORED INPUT UNIT BN-303

SINGLE MONITORED INPUT UNIT BN-303 SINGLE MONITORED INPUT UNIT BN-303 Interactive fire detection system Product Datasheet Features Interactive For interfacing switches and 3rd party detectors with relay outputs to Autronica s interactive

More information

Technical data sheet TDS0034

Technical data sheet TDS0034 Technical data sheet TDS0034 PREMIER HYDROCARBON INFRARED SENSOR CERTIFIED VERSIONS TYPES MSH-P-HC and MSHia-P-HC Patent Numbers Great Britain GB 2 401 432 & GB 2 403 291 Europe EP 1544603 & EP 1818667-Pending

More information

Industrial Grade Gas Detection

Industrial Grade Gas Detection Industrial Grade Gas Detection DETECTING THE... Difference Catalog #CB 0912 detcon inc. an company www.detcon.com Houston Odessa Shanghai Dammam Del Carmen UK Company Profile ISO 9001: 2008 Certified 105-A

More information

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger Polytron Pulsar 2 Open Path Gas Detector Dräger Polytron Pulsar 2 Open Path Gas Detector The Dräger Polytron Pulsar 2 represents the latest infrared technology in open path gas detection. Equipped with all the same functions as the standard Dräger

More information

Instructions AutroFlame IR Flame Detector BG-201/BG-21

Instructions AutroFlame IR Flame Detector BG-201/BG-21 Instructions AutroFlame IR Flame Detector BG-201/BG-21 116-P-BG201-BG21/DGB 2012-10-10 COPYRIGHT This publication, or parts thereof, may not be reproduced in any form, by any method, for any purpose. and

More information

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection DATASHEET S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection Features: Unrivalled black body rejection over a wide range of source temperatures Triple waveband infra-red

More information

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. BU-110 and BV-110 Loop Based Displays

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. BU-110 and BV-110 Loop Based Displays Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT Project No: 0003053331 Supplements Project No.: 3034449 Class: 3010 Product Name: BU-110 and BV-110 Loop

More information

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T PGF- Effective Gas Safety Proving and Gas Detection Controller Gas Pressure Proving For use with Natural Gas LPG - or Laboratory gas supplies, both high and low pressure ensuring system integrity prior

More information

incontrol Systems Inc. Flame and Gas Detection

incontrol Systems Inc. Flame and Gas Detection incontrol Systems Inc. Flame and Gas Detection Our flame and gas detectors are globally certified to the latest product approval standards Wherever toxic or combustible gases are part of an industrial

More information

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions!

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions! Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions! www.spectrex.net 2 SafEye Quasar 900 Series Open Path Gas Detector The

More information

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

DUAL MONITORED INPUT/OUTPUT UNIT BN-305 DUAL MONITORED INPUT/OUTPUT UNIT BN-30 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection

More information

Implementing Safety Instrumented Burner Management Systems: Challenges and Opportunities

Implementing Safety Instrumented Burner Management Systems: Challenges and Opportunities Implementing Safety Instrumented Burner Management Systems: Challenges and Opportunities Mike Scott, PE, CFSE Standards Certification Education & Training Publishing Conferences & Exhibits Presenter Mike

More information

IEC Functional Safety Assessment

IEC Functional Safety Assessment IEC 61508 Functional Safety Assessment Project: Detcon IR-700 Combustible Hydrocarbon Gas Sensor Customer: Detcon The Woodlands, TX USA Contract No.: Q13/06-003 Report No.: DC 13-06-003 R002 Version V1,

More information

The Art of Gas Detection

The Art of Gas Detection The Art of Gas Detection Flammable & Toxic Gas Detectors Smart Alarm Controllers Fire & Gas System Engineering Technical Service & Support 1 R.C. Systems has manufactured electronic and gas detection products

More information

PREMIER PLATINUM INFRARED GAS SENSOR

PREMIER PLATINUM INFRARED GAS SENSOR PREMIER PLATINUM INFRARED GAS SENSOR LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions *** Technical data sheet TDS0150

More information

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS MINERVA S200Plus Triple Waveband Infra-Red Flame Detection Features: Unrivalled black body rejection over a wide range of source temperatures Triple waveband infra-red solar blind flame detection for optimum

More information

Installation and Wiring 1.

Installation and Wiring 1. Installation and Wiring 1. Please read the Security Notifications in detail firstly. 2. The gas detector might install on wall or steel plate, please refer following drawing to make marking then drill

More information

United Electric Controls One Series Safety Transmitter Safety Manual

United Electric Controls One Series Safety Transmitter Safety Manual United Electric Controls One Series Safety Transmitter Safety Manual OneST-SM-02 1 INTRODUCTION This Safety Manual provides information necessary to design, install, verify and maintain a Safety Instrumented

More information

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head 4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.

More information

MSA Flame and Gas Detection. [ for the Oil, Gas and Petrochemical Industries ]

MSA Flame and Gas Detection. [ for the Oil, Gas and Petrochemical Industries ] MSA Flame and Gas Detection [ for the Oil, Gas and Petrochemical Industries ] A PASSION FOR SAFETY MSA s passion for safety comes from almost a full century of manufacturing the best-of-breed, highest-quality

More information

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2 DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection

More information

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger

More information

AutroFlame X33AF. Addendum. Multi-spectrum IR flame detector. Protecting life, environment and property...

AutroFlame X33AF. Addendum. Multi-spectrum IR flame detector. Protecting life, environment and property... AutroFlame X33AF Multi-spectrum IR flame detector Addendum Protecting life, environment and property... 116-P-X33AFADDENDUM/YGB, DEC P/N 95-8624, 2007-11-12 COPYRIGHT This publication, or parts thereof,

More information