IMO Resolution MSC 61(67): Annex 1: Part 2
|
|
- Aldous Shepherd
- 5 years ago
- Views:
Transcription
1 Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 ( F : +44 (0) E : warrington@exova.com W: IMO Resolution MSC 61(67): Annex 1: Part 2 Smoke & Toxicity A Report To: Tarkett Sommer AB Document Reference: Date: 1 st April 2010 Issue No.: 1 Page 1 Registered Office: Exova (UK) Ltd, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Reg No.SC This report in issued in accordance with our terms and conditions, a copy of which is available on request.
2 Executive Summary Objective To determine the performance of the following product when tested in accordance with IMO Resolution MSC 61(67): Annex 1, Part 2. Generic Description Product reference of floor covering Thickness Weight per unit area or density or application rate Homogenous vinyl flooring Contract Plus 14.25mm 14.79kg/m 2 adhered to a calcium silicate based board utilising Casco Proff 3448 adhesive Individual components used to manufacture composite: Homogenous vinyl floor covering Contract Plus 2mm 3150g/m 2 Tackified acrylic emulsion Casco Proff 3448 N/A 3-5m 2 per litre Calcium silicate based board Promat - Brandschutzbauplatten; 12mm 870kg/m 3 Promatect-H Please see page 5 of this test report for the full description of the product tested Test Sponsor Summary of Test Results: Tarkett Sommer AB, Division Resiliant Flooring, Technical Centre, S-37281, Ronneby, Sweden. The specimens as tested achieved the criteria for smoke generation and toxicity for floor coverings as specified in the Resolution. Date of Test 22 nd February 2010 Signatories Responsible Officer J. Lucas-Cox * Principal Chemist Authorised C. Dean * Operations Manager * For and on behalf of Exova Warringtonfire. Report Issued: 1 st April 2010 This version of the report has been produced from a.pdf format electronic file that has been provided by Exova Warringtonfire to the sponsor of the report and must only be reproduced in full. Extracts or abridgements of reports must not be published without permission of Exova Warringtonfire. Document No.: Page No.: 2 of 10
3 CONTENTS PAGE NO. EXECUTIVE SUMMARY... 2 SIGNATORIES... 2 TEST DETAILS... 4 DESCRIPTION OF TEST SPECIMENS... 5 TEST RESULTS... 6 Appendix 1 Observations during test... 9 REVISION HISTORY Document No.: Page No.: 3 of 10
4 Test Details Purpose of test This test method, adopted by the International Maritime Organisation, specifies a procedure for qualifying smoke generation and toxic potency of products and thus their suitability for use in maritime construction. The tests were performed in accordance with the procedure specified in IMO Resolution MSC, 61(67) Annex 1, Part 2 as amended by MSC/Circ.916 dated 4 th June 1999 and revised by MSC/Circ.1008 dated 8 th June 2001, and it is advised that this report is read in conjunction with these documents. Scope of test IMO Resolution MSC 61(67) Annex 1, Part 2 (Ref.1) specifies that smoke generation tests should be conducted in accordance with ISO 5659: 1994, Part 2 (Ref.2). The Resolution also details a classification system based on the maximum specific optical density of smoke occurring during the test, averaged over three replicate tests, carried out in each of three test conditions. In addition, the Resolution specifies limits for seven toxic gases which must not be exceeded in any of the three test conditions. Fire test study group/egolf Instruction to test Certain aspects of some fire test specifications are open to different interpretations. The Fire Test Study Group and EGOLF have identified a number of such areas and has agreed Resolutions which define common agreement of interpretations between fire test laboratories which are members of the Groups. Where such Resolutions are applicable to this test they have been followed. The test was conducted on the 22 nd February 2010 at the request of Tarkett Sommer AB, the sponsor of the test. Conditioning specimens Exposed face Substrate of The specimens were received on the 5 th February Prior to test the specimens were conditioned to constant mass at a temperature of 23 ± 2 C and a relative humidity of 50 ± 5%. The decorative face of the specimens was exposed to the radiant heat of the test when the specimens were mounted in the test position. The floor covering was bonded to a nominally 12mm thick calcium silicate based board utilising Casco Proff 3448 adhesive. Provision of test specimens The flooring and adhesive specimens were supplied by the sponsor of the test. Exova Warringtonfire was not involved in any selection or sampling procedure. Exova Warringtonfire supplied the substrate and bonded the composite together. Document No.: Page No.: 4 of 10
5 Description of Test Specimens The description of the specimens given below has been prepared from information provided by the sponsor of the test. All values quoted are nominal, unless tolerances are given. General description Homogenous vinyl flooring adhered to a calcium silicate based board utilising Casco Proff 3448 adhesive Contract Plus Tarkett AB See Note 1 below 14.25mm (determined by Exova Warringtonfire) See Note 1 below 14.79kg/m 2 (determined by Exova Warringtonfire) Product reference Contract Plus Name of manufacturer Tarkett AB Generic type Homogenous vinyl flooring Thickness 2mm Weight per unit area 3150g/m 2 Colour reference 466 Flame retardant details See Note 2 below Trade name Casco Proff 3448 Generic type Tackified acrylic emulsion Name of manufacturer Casco Application rate 3-5m 2 per litre Trade name of floor covering Manufacturer of floor covering Overall thickness of floor composite Overall weight per unit area of floor covering Floor Covering Adhesive (floor covering to Application method V-notched trowel substrate) Flame retardant details The sponsor of the test has confirmed that no flame retardant additives were utilised in the production of this component. Substrate Product reference Promat - Brandschutzbauplatten; Promatect-H Generic type Calcium silicate based board Name of manufacturer Promat Overall thickness 12mm Overall density 870kg/m 3 Flame retardant details The substrate is inherently flame retardant Preparation details None See Note 2 below Brief description of manufacturing process of the floor covering Note 1 the sponsor was unable to provide this information Note 2 the sponsor was unwilling to provide this information Document No.: Page No.: 5 of 10
6 Test Results Test procedure A 75mm x 75mm specimen was mounted horizontally inside a smoke chamber of the design specified in ISO 5659 Part 2, 25mm below a cone shaped, radiant electric heater capable of producing a uniform irradiance of 50kW/m 2 on the specimen surface. A premixed propane/air pilot flame of length 30mm may be applied 10mm above the specimen surface. Three replicate specimens are tested in each of the following three test conditions: 1. Irradiance of 25kW/m 2 in the presence of pilot flame. 2. Irradiance of 25kW/m 2 in the absence of pilot flame. 3. Irradiance of 50kW/m 2 in the absence of pilot flame. The attenuation of a light beam passing through the evolved smoke is measured and the results are reported in terms of the maximum Specific Optical Density attained during the test, given by the equation: Ds = (V/(A*L)*log 10 (100/T) Where: V = total volume of the chamber (m 3 ) A = exposed area of the specimen (m 2 ) L = optical length (m) of smoke measurement T = % light transmitted. Test duration is a minimum of ten minutes. This period is extended by a further ten minutes if the maximum Specific Optical Density has not been reached. The sampling of the fire effluent created in the chamber during the test for the analysis of the concentration of the seven different gases for which criteria are given is conducted using a variety of methods as defined in the internal operating procedure. In all cases, the sample is taken from the geometric centre of the chamber and sample lines are kept as short as possible. For the analysis of oxides of nitrogen and carbon monoxide, continuous measurements are made throughout the duration of the test. Carbon monoxide (CO) is determined continuously using a pre-calibrated nondispersive infra-red analyser. The values reported are those averaged over a 3 minute period of maximum smoke obscuration. Oxides of Nitrogen (NO x ) are determined continuously using a chemiluminesence analyser. Again, the values reported are those averaged over a 3 minute period of maximum smoke obscuration. Document No.: Page No.: 6 of 10
7 For the other gases, single point analysis is conducted. The gases are absorbed into aqueous media and analysed remotely. Two types of media are used; 0.1M sodium hydroxide solution and 0.3% Hydrogen Peroxide solution. The gases are sampled over a two minute period of maximum smoke density by bubbling the gases through the media using a fritted funnel Dreschel bottle arrangement. Hydrogen Cyanide (HCN) is determined from gases absorbed into a solution of sodium hydroxide and analysed using ion chromatography. Hydrogen Fluoride (HF), Hydrogen Chloride (HCl), Hydrogen Bromide (HBr) and Sulphur Dioxide (SO 2 ) are absorbed into a solution of 0.3% hydrogen peroxide and are also analysed by ion chromatography. Test Results GAS Limit (ppm) Condition 1 Reading (ppm) Condition 2 Condition 3 Carbon Monoxide CO Hydrochloric Acid HCl Hydrogen Bromide HBr 600 ND ND ND Hydrogen Fluoride HF 600 ND ND ND Hydrogen Cyanide HCN 140 ND ND ND Nitrous Fumes NO x ND 1 Sulphur Dioxide SO ND ND ND Averaged Specific Optical Density Key: ND indicates non-detected Observations recorded during the tests are detailed in Appendix 1 of this report. Summary of Results The specimens as tested achieved the criteria for smoke generation and toxicity for floor coverings as specified in the Resolution. Document No.: Page No.: 7 of 10
8 Validity This report is valid for a period for fifteen years from the date of test. This report may only be reproduced in full. Extracts or abridgements shall not be published without permission of Exova Warringtonfire. The tests results relate only to the specimens of the product in the form in which they are tested, they are not intended to be the sole criterion for assessing the potential fire hazard of the product in use. Small differences in the composition or thickness of the product may significantly affect the performance during the test and may therefore invalidate the test results. Care should be taken to ensure that any product which is supplied or used is fully represented by the specimens that were tested. The quantity of each specific toxic gas species generated is dependant upon the fire model used and the burning behaviour of the specimen during each individual fire test. The quantitative determination of combustion products therefore relates only to the specimens tested under the conditions stated and when combustion occurs as described in this test report. References 1. International Maritime Organisation Resolution MSC 61(67) 1996; The International Code for Application of Fire Test Procedures, Annex 1, Part 2: Smoke and Toxicity Test. 2. ISO 5659 Plastics - Smoke Generation - Part : Determination of Optical Density by a Single Chamber Test. Document No.: Page No.: 8 of 10
9 Appendix 1 Observations during test 25kW/m² In The Presence Of A Pilot Flame 25kW/m² In The Absence Of A Pilot Flame 50kW/m² In The Absence Of A Pilot Flame Specimen No Colour of smoke produced Expansion distance towards heater (mm) Ignition time in seconds (if applicable) Extinction time in seconds (if applicable) Dark Dark Dark Dark Dark Dark Dark Dark Dark = Did Not Occur * = Did Not Re-ignite N/A = Not Applicable Document No.: Page No.: 9 of 10
10 Revision History Issue No : Issue Date : Revised By: Approved By: Reason for Revision: Issue No : Issue Date : Revised By: Approved By: Reason for Revision: Document No.: Page No.: 10 of 10
IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:
IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2 Smoke & Toxicity Test WF Report Number: 166040 Date: 13 th August 2007 Test Sponsor: Fiba Tech Industries Ltd. 0249 Page 2 of 13 Bodycote warringtonfire
More informationReview Fire Test Report
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Review Fire Test Report Determination of
More informationBS EN ISO : 2010
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN ISO 92391: 2010 Fire Tests For Determination
More informationBS EN ISO : 2010
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Fire Tests For Determination Of The Burning
More informationBS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN ISO 1716: 2010 Determination Of The
More informationBS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com BS EN ISO 92391: 2002 Fire Tests For
More informationBS EN ISO : 2010
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN ISO 92391: 2010 Fire Tests For Determination
More informationBS 476: Part 6: 1989+A1:2009
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS 476: Part 6: 1989+A1:2009 Method Of Test
More informationNF X : Parts 1, 2, 3, 4 & 5
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com NF X 10-702: Parts 1, 2, 3, 4 & 5 Fire test
More informationAd-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Ad-hoc IEC 60331-2 x Ad-hoc investigation
More informationEN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com EN 45545-2: 2013 Summary Test Report Requirement
More informationAd-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Ad-hoc IEC 60331-2 x Ad-hoc investigation
More informationBS EN : 2001 & IEC :2000
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN 60695-2-11: 2001 & IEC 60695-2-11:2000
More informationBS 476: Part 6: 1989+A1:2009
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS 476: Part 6: 1989+A1:2009 Method Of Test
More informationIEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com IEC 60331-11-21 Method of test defined in
More informationBS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN 13823: 2010 Reaction to Fire Tests
More informationBS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN 13823: 2010 Reaction to Fire Tests
More informationwarring tonfire I I Il il il I 3 :I ~ :I :I :I =- ~ :a ::I fl ," global safety =.I =-a IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2
. l il il 3 : ;a =. : : : =-a :a =- :a :: fl MO Resolution MSC 61 (67) 1996; Annex 1, Part 2 Smoke &.Toxidty Test WF Report Number: 147535 Test Sponsor: Jotun Paints (Europe) Limited V ---- TESTNG warring
More informationBS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited
BS 476: Part 3: 2004 External Fire Exposure Roof Test WF Report Number: 153420 Date: 28 th April 2006 Test Sponsor: Tapco Europe Limited 0249 Page 2 of 9 Warringtonfire Test Report No 153420 BS 476: Part
More informationBS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 13 th October Test Sponsor: Tapco Europe Limited
BS 476: Part 3: 2004 External Fire Exposure Roof Test WF Report Number: 158117 Date: 13 th October 2006 Test Sponsor: Tapco Europe Limited 0249 Page 2 of 9 Warringtonfire Test Report No 158117 BS 476:
More informationTitle: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31.
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The Air Leakage Performance of
More informationBS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.
BS EN 60332-1-2:2004 Test On Electric And Optical Fibre Cables Under Fire Conditions WF Report Number 177604 Date: 14 th November 2008 Test Sponsor: FTC Fabbrica Trentina Conduttori Srl 0249 Page 2 of
More informationThe Fire Resistance Performance Of Timber Or Mineral Composite Based Insulated Doorsets When Fitted With D & E Architectural Hardware Spring Hinges
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The Fire Resistance Performance
More informationBS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.
BS EN 60332-1-2:2004 Test On Electric And Optical Fibre Cables Under Fire Conditions WF Report Number 177603 Date: 14 th November 2008 Test Sponsor: FTC Fabbrica Trentina Conduttori Srl 0249 Page 2 of
More informationBS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:
BS EN 61034-2: 2005 Measurements Of Smoke Density Of Electric Cables WF Report Number 177599 Date: 17 th November 2008 Test Sponsor: FTC Fabbrica Trentina Conduttori Srl 0249 Page 2 of 13 Bodycote warringtonfire
More informationTitle: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The Fire Resistance Performance
More information25 th November Title:
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The Fire Resistance Performance
More informationFire Test Reports for Interpon D Powder Coatings
Akzo Nobel Powder Coatings Ltd. Specification Fire Test Reports for Interpon D Powder Coatings Explanations and collations of key reports and approvals for the UK market. July 2017 Russell Deane Powder
More informationBS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.
BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions WF Report Number: 147709 Test Sponsor: FTC - Fabbrica Trentina Conduttori
More informationTitle: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves.
Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves Report No: 172158 Prepared for: Lindab Ventilation AB SE 26982 Båstad Järnvägsgatan
More informationTest Report: ICL/H18/9039 Rev 1
Interscience Fire Laboratory Building 63 Haslar Marine Technology Park Haslar Road, Gosport Hampshire PO12 2AG United Kingdom Tel. : +44 (0) 20 8692 5050 Fax.: +44 (0) 20 8692 5155 Email: firetesting@intersciencecomms.co.uk
More informationMethod of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.
Method of test defined in IEC 60331-21 for determining the circuit integrity performance of a cable under fire conditions. WF Report Number: 148371 Test Sponsor: FTC - Fabbrica Trentina Conduttori Srl
More informationCERTIFICATE OF APPROVAL No ME 5085
CERTIFICATE OF APPROVAL No ME 5085 1 Suite No. 52, 5 th Floor, Martin Burn Building, 1 RN Mukherjee Road, Kolkata- 700001 (West Bengal), India Tel: +91 33 40276600 Have been assessed against the requirements
More informationWARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier
Page 1 of 27 Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier Test Sponsor Saveguard (UK) Limited Warrington Fire Research Centre Ltd.,
More informationTitle: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: Indicative fire test WF Report
More informationASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process
ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process 2010 IMO FTP Code Revisions Parts 2, 5, 7, 8, 9 & 10 Presented by: Juan Manuel Flores, P.E. Date:
More informationTest Report: ICL/CR15/11/087
Interscience Fire Laboratory Building 63 Haslar Marine Technology Park Haslar Road, Gosport Hampshire PO12 2AG United Kingdom Tel. : +44 (0) 20 8692 5050 Fax.: +44 (0) 20 8692 5155 Email: firetesting@intersciencecomms.co.uk
More informationCERTIFICATE OF APPROVAL No CF 5236 EMVER PAINTS INDUSTRIES LLC
CERTIFICATE OF APPROVAL No CF 5236 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Jebel Ali Industrial
More informationTest on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in
INFRASTRUCTURE TECHNOLOGIES Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in accordance with AS/NZS 3837:1998 Fire Testing Report Author: Heherson Alarde Report Number:
More informationTest report. NanoPhos coating system EPR and EEN. Name of client: NanoPhos SA. Date: Pages: 5 Encl.: 1 Ref: BP / KTO
Test report NanoPhos coating system EPR and EEN Name of client: NanoPhos SA File no.: PFB10173A Date: 2015-10-14 Pages: 5 Encl.: 1 Ref: BP / KTO Danish Institute of Fire and Security Technology Jernholmen
More informationREACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013
SAFETY, STRUCTURES AND FIRE DEPARTMENT Reaction to Fire REACTION TO FIRE CLASSIFICATION REPORT ACCORDING TO THE EUROPEAN STANDARD NF EN 13501-1+A1:2013 Notification by the French Government to the European
More informationBS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy
BS 476: Part 7: 1997 on K-Flex IN Clad Foil Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, 36 20877 RONCELLO (MB) Italy 30 th October 2012 0578 Page 1 of 6 Prepared on behalf of BRE Global
More informationGUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS
12 December 1996 Ref. T4/4.01 GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS 1 The Maritime Safety
More informationTFI Report Reaction to fire test
TFI Report 450740-07 Reaction to fire test For the classification according to EN 13501-1:2010 Customer GÜLSEVEN HALI GÜLSEVEN TEKSTIL KIMYA GIDA SAN. TIC. LTD. STI Ahi Evran Sanayi Sitesi Istiklal Caddesi
More informationBCTC CARPET TECHNICAL CENTRE
Wira House West Park Ring Road Leeds, LS16 6QL Tel: +44 (0)113 259 1999 Fax: +44 (0)113 278 0306 Web: http://www.bttg.co.uk/bctc Email: CSLeeds@bttg.co.uk 7 September 2010 Page 1 of 7 Client: Rectory Farm
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification
More informationASTM E 662 Rate of Smoke Generation of OXIFREE TM198"
ELECTRONIC COPY ASTM E 662 Rate of Smoke Generation of OXIFREE TM198" A Report To: Oxifree Global LLC 22955 State Highway 249, Suite 6 Tomball, TX 77375 USA Phone: (281) 251-7171 E-mail: ed.hall@oxifree.com
More informationREACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013
SAFETY, STRUCTURES AND FIRE DEPARTMENT Reaction to Fire REACTION TO FIRE CLASSIFICATION REPORT ACCORDING TO THE EUROPEAN STANDARD NF EN 13501-1+A1:2013 Notification by the French Government to the European
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com CLASSIFICATION CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE
More information1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c
1.0 INTRODUCTION This report presents the results of a fire performance evaluation in accordance with the 2011 Edition of National Fire Protection Association (NFPA) Standard 265, Standard Methods of Fire
More informationASSESSMENT REVIEW. Review of Assessment Report WFRA C91415
ASSESSMENT REVIEW Review of Assessment Report WFRA C91415 Fire resistance performance of steel electrical wall boxes mounted in plasterboard partitions with modified mounting arrangements, box design and
More informationTest Report Reg.no 12.
cd?l DANAK ~ Test Report Reg.no 12. Macroplast UK 8303 B60 Fileno: PFl 7707b Seda! No: 9474 Ref: BP/MPA Ene!.: 7 Henkel KGaA The results relate only to the items tested. The test report should only be
More informationForbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.
Return address: P.O. box 337, 7500 AH Enschede, TNO Centre for Textile Research Ariënsplein 3 7511 JX ENSCHEDE Forbo Flooring Attn. Mr. A. Tijhof Postbus 13 1560 AA Krommenie Report Sponsor : Contractor,
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60754-3 Edition 1.0 2018-03 Test on gases evolved during combustion of materials from cables Part 3: Measurement of low level of halogen content by ion chromatography INTERNATIONAL
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification
More informationASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB"
UNCONTROLLED ELECTRONIC COPY ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB" A Report To: Ciucevich 7200 Vermilion Ct. Wake Forest, NC 27587 USA Phone: (919) 570-291 E-mail:
More informationClassification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:
Classification of reaction to fire performance in accordance with EN 13501-1: 2007 +A1: 2009 on Superfoil SFNC Prepared for: Boulder Developments Ltd Black Horse Farm Main Street Norwell Nottinghamshire
More informationFRANCE M & F RANKING ACCORDING TO NF F
FRANCE M & F RANKING ACCORDING TO NF F 16-101 CREPIM / http://www.crepim.com 1 The actual classification used by French regulations for the classification of fire behaviour of materials/component is described
More informationIMO COMPREHENSIVE REVIEW OF THE FIRE TEST PROCEDURES CODE
INTERNATIONAL MARITIME ORGANIZATION E IMO SUB-COMMITTEE ON FIRE PROTECTION 50th session Agenda item 10 FP 50/10/1 25 October 2005 Original: ENGLISH COMPREHENSIVE REVIEW OF THE FIRE TEST PROCEDURES CODE
More informationC-01 FIRE DECKS AND BULKHEADS
Guideline No.: C-01(201510) C-01 FIRE DECKS AND BULKHEADS Issued date: October 20,2015 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification
More informationAdditional reaction to fire classification report No H
Additional reaction to fire classification report. 12700H Owner of the additional classification report Antalis International 8 Rue de Seine 92517 Boulogne Billancourt Cedex France Introduction This additional
More informationEU DECLARATION OF CONFORMITY (Doc) issued in accordance with the MARINE EQUIPMENT DIRECTIVE (MED) and EU/US MRA
EU DECLARATION OF CONFORMITY (Doc) issued in accordance with the MARINE EQUIPMENT DIRECTIVE (MED) and EU/US MRA This is to certify that in compliance with the Directive 2014/90/EU of the European Parliament
More informationASTM E662 TESTING FOR COLE MOTORSPORTS/CM RACING PRODUCTS ON WINDSHIELD TEAROFFS ON ¼ GLASS VTEC # TESTED: MARCH 27, 2009
ASTM E662 TESTING FOR COLE MOTORSPORTS/CM RACING PRODUCTS ON WINDSHIELD TEAROFFS ON ¼ GLASS VTEC #100-3191-1 TESTED: MARCH 27, 2009 April 2, 2009 Client: Attention: Cole Motorsports/CM Racing Products
More informationStar Princess Safety Centre. Annex A
Star Princess Safety Centre Annex A Star Princess Safety Centre Star Princess has a highly automated system for managing ship emergencies. Sensors within the ship monitor the operation of key systems including
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Sponsor Prepared by P.O. Box 70 NL-5750 AB DEURNE Efectis Nederland BV Lange Kleiweg 5 P.O. Box 1090 NL-2280 CB
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554-2665 ZN Bleiswijk Brandpuntlaan Zuid 16-2665 NZ Bleiswijk +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification no.
More informationAnalysis Report
Prestige Carpets bvba Dhr. Dirk Santens Klein Frankrijk 38 9600 RONSE Your notice of Your reference Date 19-06-2013 24-07-2013 Required tests : Identification number T1309624 Information given by the client
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK
21-47 High Street, Feltham, Middlesex, TW13 4UN, UK Holmesfield Road Warrington Cheshire WA1 2DS Contact: Mr D Brown Tel: +44 (0)1925-655116 Fax: +44 (0)1925-655419 E-Mail: david.brown@exova.com Website:
More informationEN 1155:1997 TESTS OF : PERKO R106 FS CONCEALED FIXED ELECTRICALLY POWERED FREE SWING DEVICES FOR SWING DOORS. Leopold Street, Birmingham.
Exova Warringtonfire Key Industrial ark Fernside Road Willenhall West Midlands WV13 3YA T : +44 (0) 1902 722 122 F : +44 (0) 1902 727 242 E : willenhall@exova.com W: www.exova.com EN 1155:1997 TESTS OF
More informationClassification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.
Classification of reaction to fire performance in accordance with BS EN 13501-1: 2007 +A1: 2009 on Sandwich Panel, WP 50 Prepared for: Sandwich Panel Factory Jeddah Saudi Arabia 13 July 2011 0578 Page
More information26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR
INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 020 7735 7611 Fax: 020 7587 3210 Telex: 23588 IMOLDN G IMO E Ref. T4/4.01 MSC/Circ.1007 26 June 2001 GUIDELINES FOR THE
More informationCANADIAN FIRE ALARM ASSOCIATION An Update on Standards, Technologies and Solutions. Smoke Characterization Study
CANADIAN FIRE ALARM ASSOCIATION An Update on Standards, Technologies and Solutions Smoke Characterization Study October 29, 2008 Paul E. Patty, P.E. Senior Research Engineer Northbrook, IL 847-664-2752
More informationTFI Report Classification
TFI Report Classification of the Reaction to Fire according to EN 13501-1:2010 Customer Stuttgarter Straße 75 74321 Bietigheim-Bissingen GERMANY Product resilient floor covering Product 1: Scala 55 Connect
More informationPERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome
PERFORMANCE TEST REPORT Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome Report No: D3964.01-106-31 Report Date: 06/19/14 Test Record Retention Date: 06/03/18 130 Derry Court York, PA
More informationExova Warringtonfire - Expert Witness Directory 2018
Exova Warringtonfire Holmesfield Road Warrington Cheshire WA1 2DS United Kingdom T : +44 (0) 1925 655116 E : warrington@exova.com W: www.exova.com Exova Warringtonfire - Expert Witness Directory 2018 Please
More informationThe Train Now Arriving At... Harmonised Fire Safety For European Rolling Stock
The Train Now Arriving At... Harmonised Fire Safety For European Rolling Stock Beth Dean beth.dean@exova.com : The Role of Accredited Laboratories in Regulation and Market Surveillance 10 th October 2012
More informationIMO UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2 AND RELATED FIRE TEST PROCEDURES
INTERNATIONAL MARITIME ORGANIZATION E IMO SUB-COMMITTEE ON FIRE PROTECTION 46th session Agenda item 5 FP 46/5 30 November 2001 Original: ENGLISH UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2 AND RELATED
More informationCERTIFICATE OF APPROVAL No CF 5635 P3 SRL
CERTIFICATE OF APPROVAL No CF 5635 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Via Salvo D Acquisto
More informationIMO FP 53 Report. Lloyd s Register report on the 53 rd session of IMO Fire Protection Sub-Committee. 16 th March, 2009
IMO FP 53 Report Lloyd s Register report on the 53 rd session of IMO Fire Protection Sub-Committee 16 th March, 2009 Hot topics: Consideration continues on inerting to prevent fire and explosion on small
More informationGeneration, Assessment
Practical Guide to Smoke and Combustion Products from Burning Polymers - Generation, Assessment and Control Sergei Levchik Marcelo Hirschler Edward Weil Smithers ismithers /Smithers - A Smithers Group
More informationGlobal Requirements for the Fire Protection of Ships. Dr Janet Murrell Warrington Certification Ltd
Global Requirements for the Fire Protection of Ships Dr Janet Murrell Warrington Certification Ltd Arch Timber 3 rd Castleford June 2011 International Maritime Organisation (IMO) International Maritime
More informationClassification of Fire Performance of Wall and Ceiling Lining Materials
Classification of Fire Performance of Wall and Ceiling Lining Materials Using the Method of Kokkala, Thomas and Karlsson Reference: Kokkala, M.A. Thomas, P.H. and Karlsson, B. Rate of Heat Release and
More informationISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source
INTERNATIONAL STANDARD ISO 9239-1 Third edition 2010-06-15 Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source Essais de réaction au feu des
More informationQuality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.
Water Quality Labo- Soil/ Soil/ Sedi- Sam- & Air / Dust Toxic gases are present in a wide variety of industrial and civil installations and their detection and monitoring is crucial for the safe working
More informationM E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)
National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169 7471 Phone: 617 770 3000 Fax: 617 770 0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Furnishings
More informationISO 5657 INTERNATIONAL STANDARD. Reaction to fire tests Ignitability of building products using a radiant heat source
INTERNATIONAL STANDARD ISO 5657 Second edition 1997-12-15 Reaction to fire tests Ignitability of building products using a radiant heat source Essais de réaction au feu Allumabilité des produits de bâtiment
More informationInternational Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.
International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.800(19) Magnus Arvidson SP Fire Research SP Technical Research Institute
More informationTech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5
INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5 5 Tech Notes TESTING PROTOCOL Fire Retardant Gel Coats Issue Date: 4/22/2010 Document ID: TN-TS-05A 2010 Interplastic Corporation Testing Protocol
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Building 63 Haslar Marine Technology Park Haslar Road Gosport Hampshire PO12 2AG Contact: Mr S Kumar Tel: +44 (0) 208 692 5050 Fax: +44 (0)
More informationTest Report No: ICL/H17/7967
2294 Notified Body No 2700 Interscience Fire Laboratory Building 63 Haslar Marine Technology Park Haslar Road, Gosport Hampshire PO12 2AG United Kingdom Tel. : +44 (0) 20 8692 5050 Fax.: +44 (0) 20 8692
More informationP R O D U C T D ATA S H E E T
TOCSIN 750 SERIES ANNUNCIATORS Addressable Gas Detection Interface Point -Wire Addressable Systems Sounder Display Shows: Reading-Message-Alarm RGB Relay Output off Solid State Beacon Sounder Output off
More informationReport VNLF Test Report
Report VNLF 081158.1 Test Report Applicant KLEEN-TEX Industries in Europa GmbH Münchner Straße 21 6330-Kufstein Austria Reference Mrs. Antje Schlegel Application Determination ofthe burning behaviour according
More informationSieger Apex. Flexibility that meets your requirements
Sieger Apex Flexibility that meets your requirements Sieger Apex Easy to Install Sensor can be remotely mounted up to 100m from the transmitter On board relays allow for local audible/ visual alarms Strong
More informationAGT 1 Confined Space. Authorised Gas Tester 1. Scienco Limited. Authorised Gas Tester 1 1
Scienco Limited AGT 1 Confined Space Authorised Gas Tester 1 Instructor: Gary Taylor E-Mail: gary@scienco.com Phone: +44 117 971 0001 Office: 10 Chapel Way, Bristol UK BS4 4EU Office Hours: 08:30 to 17:00
More informationREACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013
SAFETY, STRUCTURES AND FIRE DEPARTMENT Reaction to Fire REACTION TO FIRE CLASSIFICATION REPORT ACCORDING TO THE EUROPEAN STANDARD NF EN 50-+A:20 Notification by the French Government to the European Commission
More informationGlenside Environmental Services Ltd
Unit 18 Great Island Industrial Park, Ballincollig, Co. Cork. Testing Laboratory Registration number: 322T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the Schedule
More informationUL MATERIAL YELLOW CARD GRILON ANNEX Material certificates : Background information and classification information acc. to EN 45545-2 The European standard EN 45545-2 classifies the requirements for fire
More information