1 POWERFOIL X3.0 ELECTRICAL SPECS & DIAGRAMS WARNING: Disconnect power to the installation locations before installing the fan and controller! WARNING: Wait three minutes after disconnecting the VFD before servicing! WARNING: Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. Incorrect assembly can cause electric shock or damage the motor and the controller. Supply power guidelines Before beginning fan installation, route power wiring to the VFD installation site. Refer to the minimum supply circuit requirements for your fan size below. foil X3.0 Fan Diameter Minimum Circuit Size 1 PFX ft (2.4 m) PFX ft (3.0 m) PFX ft (3.6 m) PFX ft (4.3 m) PFX ft (4.9 m) PFX ft (5.5 m) PFX ft (6.1 m) PFX ft (7.3 m) V, 1 Φ V, 3 Φ V, 3 Φ V, 1 Φ V, 3 Φ V, 3 Φ V, 1 Φ V, 3 Φ V, 3 Φ V, 3 Φ foil X3.0 Plus Fan Diameter 2 Minimum Circuit Size 1 PPX ft (3.6 m) PPX ft (4.3 m) PPX ft (4.9 m) V, 1 Φ V, 3 Φ PPX ft (5.5 m) V, 3 Φ PPX ft (6.1 m) V, 3 Φ PPX ft (6.7 m) PPX ft (7.3 m) 1. All VFDs produce three-phase output power regardless of input phase. 2. With foil Plus winglets wiring guidelines Dedicated Branch Circuit Protection. Each fan requires dedicated branch circuit protection. Conduit. VFD output/motor input leads cannot share a conduit with any other controller s supply feed. Local Disconnect. If required, a local disconnect should be installed per all national and local codes. Manual Disconnect. To satisfy some local code requirements, it may be necessary to install a manual disconnect at the fan motor location when the fan is not within line-of-sight of the controller.

2 : V, 1 Φ Note: Fire relay not shown. See Fire Relay for fire relay wiring instructions. The diagram below shows a standard VFD ( V, 1 Φ) using single-phase input from power supply. Actual component layout may differ from illustration. / NEMA L6-20P (1.0 hp) or NEMA L6-30P ( hp) /

3 : V, 1 Φ with EMI filter Note: Fire relay not shown. See Fire Relay for fire relay wiring instructions. The diagram below shows a typical EMI filter installation on a standard VFD ( V, 1 Φ) using single-phase input from power supply. Actual component layout may differ from illustration. / NEMA L6-20P (1.0 hp) or NEMA L6-30P ( hp) / /

4 : V, 3 Φ Note: Fire relay not shown. See Fire Relay for fire relay wiring instructions. The diagram below shows a standard VFD ( V, 3 Φ) using three-phase input from power supply. Actual component layout may differ from illustration. / NEMA L15-20P /

5 : V, 3 Φ with EMI filter Note: Fire relay not shown. See Fire Relay for fire relay wiring instructions. The diagram below shows a typical EMI filter installation on a standard VFD ( V, 3 Φ) using three-phase input from power supply. Actual component layout may differ from illustration. / NEMA L15-20P / /

6 : V, 3 Φ Note: Fire relay not shown. See Fire Relay for fire relay wiring instructions. The diagram below shows a standard VFD ( V, 3 Φ) using three-phase input from power supply. Actual component layout may differ from illustration. / NEMA L16-20P /

7 : V, 3 Φ with EMI filter Note: Fire relay not shown. See Fire Relay for fire relay wiring instructions. The diagram below shows a typical EMI filter installation on a standard VFD ( V, 3 Φ) using three-phase input from power supply. Actual component layout may differ from illustration. / NEMA L16-20P / /

8 RUN STOP FWD REV : V, 3 Φ Note: Fire relay not shown. See Fire Relay for fire relay wiring instructions. The diagram below shows a standard VFD ( V, 3 Φ) using three-phase input from power supply. Actual component layout may differ from illustration. / MODE RUN ENTER STOP RESET VFD-M 1.5KW WARNING: /

9 Fire relay wiring (E Series) ON From main FP or N box (if applicable) A contact closure across digital input terminals MI3 and DCM will result in fan shutdown. The relay uses a Normally Open (N.O.) contact. The relay coil must be energized by the FP for fan shutdown. Two additional relay coil leads are provided to facilitate supervision pass-through where required. An alarm condition will stop the fan and issue a fault at the controller. (X2) (X2) (+) (-) COMMON CLOSED OPEN COIL: ma ON From main FP or N box (if applicable) Optionally, the relay can be used with a Normally Closed (N.C.) contact. The relay coil must remain energized by the FP for fan operation. This would be considered a fail safe or fail open wiring arrangement. F H U Two additional relay coil leads are provided to facilitate RUN STOP FWD REV REM LOC supervision pass-through where required. An alarm condition will stop the fan and issue a fault at the controller. (X2) (X2) (+) (-) COMMON CLOSED OPEN COIL: ma

10 Fire relay wiring (M Series) From main FP or N box (if applicable) A contact closure across digital input terminals M3 and GND will result in fan shutdown. The relay uses a Normally Open (N.O.) contact. The relay coil must be energized by the FP for fan shutdown. RUN STOP FWD REV MODE RUN ENTER STOP RESET Two additional relay coil leads are provided to facilitate supervision pass-through where required. VFD-M 1.5KW An alarm condition will stop the fan and issue a fault at the controller. U T1 V T2 W T3 Brake B1 B2 (X2) (X2) (+) (-) COMMON CLOSED OPEN COIL: ma From main FP or N box (if applicable) Optionally, the relay can be used with a Normally Closed F (N.C.) H contact. The relay coil must remain energized by the U FP for fan operation. This would be considered a fail safe RUN STOP FWD REV REM LOC or fail open wiring arrangement. RUN STOP FWD REV MODE RUN ENTER STOP RESET Two additional relay coil leads are provided to facilitate supervision pass-through where required. VFD-M 1.5KW An alarm condition will stop the fan and issue a fault at the controller. U T1 V T2 W T3 Brake B1 B2 (X2) (X2) (+) (-) COMMON CLOSED OPEN COIL: ma

Model 4880 Status Output Display Module Manual

Model 4880 Status Output Display Module Manual Model 4880 Status Output Display Module Manual 1-2 150912 Section 1 Introduction The 4880 provides 16 switched outputs, 4 form C relay contacts, and an X10 module interface. See Table 2-1 for electrical

More information

Heatrix Electric Duct Heater HXOB Installation Instructions

Heatrix Electric Duct Heater HXOB Installation Instructions Heatrix Electric Duct Heater HXOB Installation Instructions General: Heatrix HXOB Style Electric Duct Heater has been tested and listed for close-coupled application with a forced air system (straight

More information

ADC150 Automatic Draft Control

ADC150 Automatic Draft Control Installation & Operating Manual ADC150 Automatic Draft Control USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

SERVICE BY QUALIFIED PERSONNEL ONLY

SERVICE BY QUALIFIED PERSONNEL ONLY Installation Instructions Automatic Load Control Relay For Emergency Lighting! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA) INSTRUCTION MANUAL AlarmGard Chain Operator (Model FCA) & AlarmGard Crank Operator (Model FKA) WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within

More information

EEMAX ProAdvantage Series 1

EEMAX ProAdvantage Series 1 EEMAX ProAdvantage Series 1 ELECTRIC INSTANTANEOUS WATER HEATER INSTALLATION GUIDE AND OWNER S MANUAL MODELS COVERED: PA004120T 1Φ 120V PA008208T 1Φ 208V PA005240T 1Φ 240V PA007240T 1Φ 240V PA010240T 1Φ

More information

EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ...

EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Installation & Operating Manual EBC 10 Fan Control USA CAN Product Information... Chapter 1+2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration... Chapter

More information

Ammonia Detection System Codes and Design Specifications

Ammonia Detection System Codes and Design Specifications Ammonia Detection System Codes and Design Specifications January 15, 2018 Revision 6 Ammonia detection system codes and design specifications Following is a discussion of ammonia detection system design

More information

Figure 30: Sample Case 8

Figure 30: Sample Case 8 6.9 Sample Case 8 C-A, φ-φ fault on Line 512 Hidden failure: Line 504 PCB scheme low set fault detector picked up This case illustrates the security of the line. With the low set fault detector of the

More information

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION R SERIES 35-61 24 VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay F-35-61 August 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE HEATPUMP 100% OUTDOOR AIR VERSION Telephone:

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE HEATPUMP 100% OUTDOOR AIR VERSION Telephone: ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE HEATPUMP 100% OUTDOOR AIR VERSION 2.0 www.addison-hvac.com Telephone: +1.407.292.4400 1 2 OCCUPIED MODE: When the program control source calls for

More information

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA) R SERIES 35-70 120 VAC Microprocessor-Based Direct Spark Ignition Control F-35-70 November 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings

More information

Power Supply Display Module PSDM. Installation and Operation Manual

Power Supply Display Module PSDM. Installation and Operation Manual Power Supply Display Module PSDM Installation and Operation Manual Read this manual before using this product. Failure to follow the instructions and safety precautions in this manual can result in serious

More information

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual ITC 2000 HEATING CONTROL CABINET Installation & Operation Manual VTI, Incorporated 24 McMillan Way Newark, DE 19713 Phone (302) 738 0500 FAX (302) 738 6594 Revision Level 0.03 Manual No. 90003314 June,

More information

Troubleshooting Guide

Troubleshooting Guide Gas Safety Products 26/01/2016 S&S Northern Ltd 1 Table of contents 1 General information... 3 2 Fault LED... 3 2.1 No Power LED Illuminated... 3 2.2 Emergency Stop Fault... 3 2.3 Fan Fault... 3 2.4 Additional

More information

FLAKER/DCM SEQUENCE OF OPERATION

FLAKER/DCM SEQUENCE OF OPERATION FLAKER/DCM SEQUENCE OF OPERATION H O S H I Z A K I A M E R I C A The Flaker and DCM series of ice machines use a completely different ice making process than the cuber style of icemaker. The Flaker has

More information

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/ CONTROL DEVICE UL 1008-BCELTS UL 924-Switch Bypass! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS

More information

CENTRO-MATIC - 278B. Model Controller Series C JAN Section - C8. Form Page. Indicates change

CENTRO-MATIC - 278B. Model Controller Series C JAN Section - C8. Form Page. Indicates change Model 85535 Controller Series C JAN - 06 Section - C8 Page - 278B Table of Contents Safety...2 Controller Operation...2 Description...2 Field Connections...3 Wiring Diagram...3 Contoller Components and

More information

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804 #4202 2 amp #4204 4 amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL 4202/4MA, Rev. E 0804 4202/4204 Power Supply Fused 115 V Input Low Battery Indicator DC Output Adjustable 0.7 to 3.7 Volts from nominal

More information

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES USER INSTRUCTIONS FOR THE CHEMGARD INFRARED GAS MONITOR SERIES To completely customize the specification to your exact application, modification to the

More information

LaserGuard2. Laser Collision Avoidance System. Part Number: R1 April 2015 Copyright 2015 Magnetek Material Handling

LaserGuard2. Laser Collision Avoidance System. Part Number: R1 April 2015 Copyright 2015 Magnetek Material Handling LaserGuard2 Laser Collision Avoidance System Part Number: 147-20004 R1 Copyright 2015 Magnetek Material Handling Table of Contents Service Contact Information... 3 1. Preface and Safety... 4 1.1. Product

More information

CM R-410A High Efficiency Water Source Heat Pump

CM R-410A High Efficiency Water Source Heat Pump CM R-410A High Efficiency Water Source Heat Pump MODEL CM - Heat pump nominal capacities 8,000 12,000 15,000 Btuh 2.6 3.5 4.4 kw The Right Fit for Comfort Specifications and Performance ECR International

More information

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

La Marche Manufacturing Company   Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual La Marche Manufacturing Company www.lamarchemfg.com Option 16 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain

More information

BGH Series Hot Surface Ignition Control

BGH Series Hot Surface Ignition Control Installation Instructions BGH Series Issue Date April 14, 2011 BGH Series Hot Surface Ignition Control Application The BASO Gas Products BGH Series Hot Surface Ignition (HSI) control is microprocessor

More information

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN 04-350 Product Installation

More information

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC. M Series Multi-Output Access Control Power Supply Charger Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 4 amp @ 12VDC or 3 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp @

More information

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS SERIES 35-65 24 VAC Microprocessor-Based Hot Surface Ignition Control F-35-65 August 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings* 120/240

More information

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction Hoffman Controls Installation & Operating Instructions Introduction CAUTION Failure to read and understand the accompanying instructions and diagrams prior to energizing the Controller may result in permanent

More information

CommStat 4 Controller

CommStat 4 Controller CommStat 4 Controller CommStat 4 Telecom HVAC Controller The CommStat 4 is an HVAC controller designed specifically for controlling two redundant air conditioners, heat pumps and air conditioners with

More information

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...

More information

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature AutoTest VSR (VSR-AT) (EU) Features Assembled in USA 0-30 second field replaceable electronic retard Two SPDT (Form C) switch contacts Weatherproof Easy to read wire terminal designations Easy to read

More information

Troubleshooting Guide

Troubleshooting Guide Merlin CT1250 Gas Interlock System Gas Safety Products 26/01/2016 S&S Northern Ltd 1 Table of contents 1 General information... 3 2 Fault LED... 3 2.1 No Power LED Illuminated... 3 2.2 Emergency Stop Fault...

More information

ENERVEX ADC100 DRAFT CONTROL

ENERVEX ADC100 DRAFT CONTROL ENERVEX ADC100 DRAFT CONTROL 3916067 04.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238 F: 770.587.4731

More information

CR Series Command Relays

CR Series Command Relays CR Series Command Relays FEATURES INSTALLATION INSTRUCTIONS Patented 35mm Din-rail mounting flange (US Patent 7,416,421) SPDT Form 1C Relay contacts Pilot duty rated LED status indication Stackable for

More information

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger Installation Guide for AL400ULM Multi-Output Access Control Power Supply Charger R AL400ULM - Multi-Output Access Control Power Supply/Charger Rev. 072500 Overview: The AL400ULM multi-output access control

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET CommStat 6 Controller for Redundant HVAC Systems PRODUCT DATA SHEET General Description The CommStat 6 HVAC controller is designed for controlling up to six redundant air conditioners in an E-House or

More information

REV: 000. Radiant Flash Service Manual

REV: 000. Radiant Flash Service Manual REV: 000 Radiant Flash Service Manual Table Of Contents Introduction 3 Standard Operating Guide 3 Installation 4 External Layout 5-6 Internal Layout 7 Wiring Diagram 8 F.A.Q. 9-12 Comprehensive Parts List

More information

Installation Guide for models:

Installation Guide for models: 140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal3FD - 12VDC @ 4.6 amp or 24VDC @ 5.2 amp. - Sixteen (16) PTC protected power-limited outputs.

More information

DIGITAL METERS Large Display Temperature Meters Instruction Manual

DIGITAL METERS Large Display Temperature Meters Instruction Manual DIGITAL METERS Large Display Temperature Meters PD755 PD756 PD757 Handles Thermocouple & RTD Inputs with Simplicity J, K, T, E, R, & S Thermocouples 100 Ω Platinum RTD (0.00385 or 0.00392 curve) Large

More information

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation PS6 SERIES Power Supplies PS6 SERIES Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation and Specifications Manual ISDPS6_SERIES 08121590 PCN15016 R05/15GR

More information

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev Installation Guide for AL600ULM Multi-Output Access Control Power Supply Charger Rev. 091800 1 AL600ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL600ULM multi-output access control

More information

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE ANSUL INSTALLATION OPERATION AND MAINTENANCE MANUAL ANSUL AUTOMAN II-C RELEASING DEVICE 001799 This manual is intended for use with the ANSUL AUTOMAN II-C Releasing Device. Those who install, inspect,

More information

Installation Guide for models:

Installation Guide for models: 140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal11F - Power Supply 1: 12VDC @ 3.3 amp or 24VDC @ 3.6 amp. - Power Supply 2: 12VDC @ 3.3 amp

More information

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC. M Series Multi-Output Access Control Power Supply Chargers Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 3 amp @ 12VDC or 4 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp

More information

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger Installation Guide for AL300ULM Multi-Output Access Control Power Supply Charger R AL300ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL300ULM multi-output access control power supply/charger

More information

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL ECW-GF with FTC-PSK pipe stand and power connection kit ECW-GF using RayClic power connection kit ECW-GF-DP remote display panel available only with

More information

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

La Marche Manufacturing Company   Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual La Marche Manufacturing Company www.lamarchemfg.com Option 46 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain

More information

ESP TECHNOLOGIES LIMITED

ESP TECHNOLOGIES LIMITED Alarm Technology ESPAN-01 Series Annunciator System Combination type User Manual (Rev. 1) ESP TECHNOLOGIES LIMITED www.esptechno.com Content Page Introduction 2 General Description 2 Overview - Annunciator

More information

CONTROL PANEL INSTRUCTIONS RSQ-4

CONTROL PANEL INSTRUCTIONS RSQ-4 CONTROL PANEL INSTRUCTIONS RSQ-4 FOR SIRAC AIR TO WATER HEAT PUMP (SINGLE COMPRESSOR, AIR TO WATER) 1) System Configuration This system is composed of mainboard and wire control panel. 146mm Φ4 4 Mainboard

More information

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS SERIES 35-63J INSTALLATION INSTRUCTIONS FOR REPLACING JOHNSON CONTROLS G77X AND OTHER MODELS WITH FENWAL SERIES 35-63J IP IGNITION CONTROL APPLICATIONS The Fenwal 35-63J series Intermittent Pilot Ignition

More information

ACL TC 200 TEMPERATURE CONTROLLER

ACL TC 200 TEMPERATURE CONTROLLER TC 200 TEMPERATURE CONTROLLER TC 200 TEMPERATURE CONTROLLER WARNING This manual must be read in its entirety before installation of this controller. Installation must be performed by a qualified technician

More information

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

CN7232 Advanced Garage Ventilation Controller

CN7232 Advanced Garage Ventilation Controller CN7232 Advanced Garage Ventilation Controller For Demand Controlled Ventilation Using: Carbon Monoxide (Gas Vehicles) Nitrogen Dioxide (Diesel) Combustible Gases (Alternative Fuels) Carbon Dioxide (Any

More information

FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual

FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual Table of Contents Introduction 1 System Components 2 Wiring Block Diagram 3 Connection Diagram for One Sensor 4 Connection Diagram for Multiple

More information

SPECIFICATIONS. Contents List

SPECIFICATIONS. Contents List INSTALLATION INSTRUCTIONS FOR PB-SA PUSH BUTTON SYSTEM ABORT The information contained in this installation instruction is a quick reference guide. For detailed system information refer to the panel manufacturers

More information

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL. Page 1 / 15 Installation and user manual Page 2 / 15 Sira s.r.l. reserves the right to make modifications to this manual and the product described herein without prior notice. Sira s.r.l. shall not be

More information

SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW

SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES Mounting brackets Heater thermostat (3R only) Power on light HTC energized light Heater (3R only) Snow/Ice

More information

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1 Gas Safety Products Merlin CT1650+ Gas Interlock System Installation, operating and maintenance 09/05/2016 S&S Northern Ltd 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel

More information

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs ACM8 Series UL Listed Sub-Assembly Access Power Controllers Installation Guide Models Include: ACM8 - Eight (8) Fuse Protected Outputs ACM8CB - Eight (8) PTC Protected Outputs Rev. 042811 More than just

More information

Instruction Manual Model L2 RF Switch

Instruction Manual Model L2 RF Switch Instruction Manual Model 1582-22L2 RF Switch November 2015, Rev. A CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL REMOTE ONLINE

More information

THERMAL MANAGEMENT SOLUTIONS

THERMAL MANAGEMENT SOLUTIONS DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL ECW-GF with FTC-PSK pipe stand and power connection kit ECW-GF using RayClic power connection kit ECW-GF-DP remote display panel available only with

More information

ADDITIONAL INFORMATION

ADDITIONAL INFORMATION MODEL APS-3C AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL MODEL APS-4C AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL MODEL SC-40C MODULAR SNOW/ICE HEATER CONTROL SYSTEM SAFETY This device provides

More information

CXM/DXM. Application, Operation & Maintenance Instructions 97B0003N08 Revision: 01/10/05. CXM/DXM Digital Heat Pump Controllers.

CXM/DXM. Application, Operation & Maintenance Instructions 97B0003N08 Revision: 01/10/05. CXM/DXM Digital Heat Pump Controllers. CXM/DXM CXM/DXM Digital Heat Pump Controllers Application, Operation & Maintenance Instructions 97B0003N08 Revision: 01/10/05 Table of Contents CXM / DXM Control Features Comparison 2 Part I - CXM Control

More information

HALOGUARD TM IR MONITOR (OPTIONAL) FOUR or EIGHT POINT SCANNER INSTRUCTION MANUAL

HALOGUARD TM IR MONITOR (OPTIONAL) FOUR or EIGHT POINT SCANNER INSTRUCTION MANUAL HALOGUARD TM IR MONITOR (OPTIONAL) FOUR or EIGHT POINT SCANNER INSTRUCTION MANUAL SE R IA L N O. M O D E L N O. Tem p. Range 1 - = > 60 o F 2 - = 40-60 o F 3 - = < 40 o F G as Type 1 - R-11 2 - R-12 3

More information

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev RPSMLR2 RPSMLR2BB Panic Device Power Controller Installation Guide LISTED Rev. 102715 Overview: RPSMLR2BB, RPSMLR2 will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed

More information

AMERITROL, INC. INSTALLATION OPERATION MANUAL AND WIRING DIAGRAM FX SERIES FLOW SWITCH WITH ADDITIONAL TEMPERATURE SWITCH. Manual Number: FXTX2116-1

AMERITROL, INC. INSTALLATION OPERATION MANUAL AND WIRING DIAGRAM FX SERIES FLOW SWITCH WITH ADDITIONAL TEMPERATURE SWITCH. Manual Number: FXTX2116-1 AMERITROL, INC. INSTALLATI OPERATI MANUAL AND WIRING DIAGRAM FX SERIES FLOW SWITCH WITH ADDITIAL TEMPERATURE SWITCH Manual Number: FXTX6-85L Park Center Dr. Vista CA 908-760-77-77 -800-90-6689-760-77-75

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 031-01284-000/50A55-241 Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR

More information

SP-1000X. Panic Device Power Controller Installation Guide. Rev

SP-1000X. Panic Device Power Controller Installation Guide. Rev TM SP-1000X Panic Device Power Controller Installation Guide Rev. 120213 Overview: SP-1000X will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed to handle the high current

More information

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

STATUS ALARM ALARM HISTORY POWER HISTORY RESET Instruction Manual Model 1582-152 RF Protection Switch November 2009, Rev B. CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL

More information

Powerohm Resistors Digital HRG System

Powerohm Resistors Digital HRG System Installation and Operating Instructions Powerohm Resistors Digital HRG System This manual provides general information, installation, operation, maintenance, and system setup information for the Powerohm

More information

ECO N DATE DESCRIPTION OF CHANGE CHG

ECO N DATE DESCRIPTION OF CHANGE CHG Model Number: M21E-24-DIN Description: The product is a loop powered device which controls an unsupervised dual pole output channel suitable to manage 24VAC loads. The M21E-24-DIN is micro-controller operated,

More information

MBCE-110/230UV Flame Sensor Module

MBCE-110/230UV Flame Sensor Module MBCE-1002 FEBRUARY 3, 2017 MBCE-110/230UV Flame Sensor Module DESCRIPTION The MBCE-110/230UV modules provide visual indication and electrical outputs that signal the user regarding flame presence in a

More information

50A Integrated Furnace Control

50A Integrated Furnace Control 50A56-956 Integrated Furnace Control INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY

More information

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2 I&M NUMBER: 316-42-15-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

FEC400 Series. Installation Manual

FEC400 Series. Installation Manual FEC400 Series Conventional microprocessor controlled fire detection and alarm panels with extinguishing control Installation Manual Version 2.3 / August 2004 Aritech is a GE Interlogix brand. http://www.geindustrial.com/ge-interlogix/emea

More information

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER JOCKEY PUMP CONTROLLER Model JPCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page 4 Model

More information

Honeywell ENERGY SAVINGS KIT

Honeywell ENERGY SAVINGS KIT ENERGY SAVINGS KIT 1. Application The Honeywell Energy Savings Kit reduces energy consumption by sending a dry contact signal to a Honeywell thermostat to change its set-point (increase in cooling mode)

More information

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual MANUAL We manage heat Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual Environmental Technology, Inc. 1850 N Sheridan Street South Bend, Indiana 46628 http://www.networketi.com/

More information

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD BURNER MANANGEMENT SYSTEM NXF4000-SPEC AUGUST 5 2017 PRODUCT GUIDE SPECIFICATION FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD GENERAL OVERVIEW 1.1.1. Each burner shall

More information

THERMAL MANAGEMENT SOLUTIONS

THERMAL MANAGEMENT SOLUTIONS Pipe Freeze Protection and Flow Maintenance ECW-GF, ECW-GF-DP Digital electronic controllers and remote display panel Fire Sprinkler System Freeze Protection ECW-GF with FTC-PSK pipe stand and power connection

More information

AquaSaver DISPOSER CONTROL CENTER Installation Manual. Model AS-101K

AquaSaver DISPOSER CONTROL CENTER Installation Manual. Model AS-101K AquaSaver DISPOSER CONTROL CENTER Installation Manual Model AS-1K The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury. The Warning

More information

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL Crypto-Lock Model CC-8521B Updated 7/17 Access Control System INSTRUCTION MANUAL MONITEQ, Inc. 2 TABLE OF CONTENTS 1. INTRODUCTION..4 2. SPECIFICATIONS.....6 3. SUPPLIED EQUIPMENT.. 6 4. FUNCTIONS OF CONTROLS

More information

Tri-Stack Smart System

Tri-Stack Smart System Tri-Stack Smart System TM Notes & Warnings - The protection provided by this equipment may be impaired if it is not used in the manner specified herein. - Ensure all wiring meets applicable national and

More information

UNIT DIGITAL CONTROLS APPLICATION, OPERATION & MAINTENANCE

UNIT DIGITAL CONTROLS APPLICATION, OPERATION & MAINTENANCE DM2 Digital Heat Pump Controller Rev: 3 November 2017 DM2 Overview 3 Physical Dimensions and Layout 4 Layout and Connections 5 Field Selectable Inputs 6 Safety Features 8 Unit Operation Description 10

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

PRYCO, INC. FUEL CONTROL

PRYCO, INC. FUEL CONTROL PRYCO, INC. FUEL CONTROL and MONITORING SYSTEM Page 1 DETAIL SPECIFICATIONS INTRODUCTION PRYCO s FUEL CONTROL and MONITORING (FCM) system is the most sophisticated and powerful control tool available for

More information

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual prior to installing and/or servicing this product. As with all releasing device

More information

120 VAC SYSTEM CONTROL KIT

120 VAC SYSTEM CONTROL KIT 120 VAC SYSTEM CONTROL KIT Designed for use on SWG Series Power Vent Hoods for controlling oil fired heating appliances with 120 VAC controls. Model: CK-63 The CK-63 control has the ability to operate

More information

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

YP7899C SERIES Burner Management Panel

YP7899C SERIES Burner Management Panel YP7C1000 700 SERIES Burner Management Panel INSTALLATION INSTRUCTIONS 65-00, ST700A,C 700 SERIES Plug-In Purge Timer 65-0, S710M Modbus Module 60-06, C707, C7035, C70, C77 Minipeeper UV Flame Detector

More information

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector) SMAC Controller Industrial Lubrication Systems Operation The SMAC Controller is a multi-purpose programmable controller used with industrial lubrication systems. Controller settings are saved whenever

More information

INTRODUCTION / TABLE OF CONTENTS

INTRODUCTION / TABLE OF CONTENTS 1 2 INTRODUCTION / TABLE OF CONTENTS Step One The LVCN 20 and LVCN 100 Series are general purpose level controllers offered in two configurations for pump and valve control. The LVCN 100 Series features

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 50A55-286 Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR

More information

MANUAL RESET ALARM RELEASE BOX

MANUAL RESET ALARM RELEASE BOX MANUAL RESET ALARM RELEASE BOX (For 100~240VAC or 24VAC or 24VDC) INSTRUCTION MANUAL WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08 GasScanner 8C Eight Channel Monitor Operator s Manual MINT-0281-XX Rev. A 01/29/08 Product Warranty Matheson Tri-Gas, Inc., warrants gas alarm equipment sold by us to be free from defects in materials,

More information

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External

More information