1 BuckeyeCOMPLETE:Layout 1 5/24/07 4:06 PM Page 1 BUCKEYE FIRE EQUIPMENT American Made Since Fire Equipment Product Catalog

2 BuckeyeCOMPLETE:Layout 1 5/24/07 4:06 PM Page 2 Company and Product Profile Buckeye Fire Equipment A Tradition of Innovation and Reliability In the fire protection industry for over 35 years, the Buckeye Fire Equipment Company is an innovative manufacturer of a complete line of Underwriters Laboratories (UL) Listed fire protection products: Portable and wheeled fire extinguishers Dry chemical extinguishing agents Firefighting foam concentrates and foam hardware Engineered restaurant fire suppression systems At our 165,000 square foot manufacturing facility located near Charlotte, North Carolina, Buckeye Fire Equipment produces high quality and reliable fire protection equipment for national and international markets. With sales and warehouse centers strategically located throughout the United States, as well as a global network of authorized distributors, Buckeye Fire Equipment is ready to provide its customers with timely and efficient sales, delivery, and service. Fire Extinguishers Portable Hand and Wheeled At the heart of the Buckeye Fire Equipment product lines are the hand-portable dry chemical fire extinguishers. The performance reliability of these extinguishers is a direct result of the stringent controls under which each component is produced. We mill and blend our own dry chemical agents (monoammonium phosphate based [ABC], potassium bicarbonate based [Purple K], and sodium bicarbonate based [Standard]) on site where each batch is tested and verified to meet our in-house and UL quality requirements. In our machining centers we produce our cylinders and valve component parts to exacting standards that are quality-assured by a manufacturing and inspection system certified to the latest revision of the ISO 9001 Quality Standard. On one of the most modern automated process lines in the world, the extinguishers are filled, pressurized, and leak tested to assure that only the highest quality extinguishers reach our customers. ABC Fire Extinguisher at Work Buckeye Fire Equipment also manufactures a wide selection of hazard specific fire extinguishers to meet your individual fire protection needs. These include clean gas extinguishers such as Carbon Dioxide and Halotron, the Class K Wet Chemical extinguishers used for kitchen fire suppression, Class D extinguishers for use on metal fires, and the Water Mist extinguishers suitable for use on Class A fires where a Class C hazard may also exist.

3 BuckeyeCOMPLETE 5/24/07 4:53 PM Page 3 If your situation requires more fire-stopping power, Buckeye offers clean gas agents and all three of our dry chemical agents in easily transportable wheeled units. Depending on the extinguishing agent you select, these wheeled units are available in capacities ranging from 50 lbs. to 350 lbs. Please refer to the Catalogue Product Tables for the models and sizes offered. Buckeye Kitchen Mister UL 300 Restaurant Fire Suppression System Firefighting Foams and Hardware With one of the world s largest capacity foam blending operations, Buckeye Fire Equipment produces a comprehensive line of firefighting foam concentrates recognized through independent tests as among the best in the industry. Our wide array of foam concentrates assures that there is one designed to meet your fire suppression requirements. As committed as we are to the quality and performance of our foam concentrates, we are also committed to protecting the environment - our foam concentrates are manufactured without any EPA reportable components. Buckeye Fire Equipment is proud to introduce the next generation of UL-300 Restaurant Cooking Area Fire Suppression Systems, the Buckeye Kitchen Mister Suppression System. Although many restaurant systems brag about product innovation, improved technology, fire fighting ability, and ease of installation, the Buckeye Kitchen Mister is the first product to truly deliver on that promise. By combining the fire fighting ability of misting technology, common sense features, and time saving patented innovations, the Kitchen Mister makes all other systems seem complicated and outdated. If reducing installation time by up to 50% is important to you, then your system has arrived. Knocking Down the Fire with Buckeye Foam To complement the firefighting foam product line, Buckeye Fire Equipment manufactures foam storage, proportioning, and delivery hardware that can be engineered for your specific needs. This hardware may be used in both fixed or portable system installations. Our expert technical staff can assist you in determining the most effective application for your potential hazard. Buckeye Fire Equipment Research and Development Center Customer Driven to Serve You Buckeye Fire Equipment is a customer driven company that prides itself on earning your business with every call. If you have questions about any of the products in this catalogue please do not hesitate to contact us.

4 BuckeyeCOMPLETE:Layout 1 5/24/07 4:07 PM Page 4 Portable Extinguisher Selection Guide The National Fire Protection Association (NFPA) has established the requirements for the number, size, placement, performance, and maintenance of portable fire extinguishers. These requirements are contained in NFPA 10, Standard for Portable Fire Extinguishers. Within this Standard it is stated that the selection of fire extinguishers for a given situation is determined by the character of the fires anticipated to be encountered, the construction and occupancy of the property to be protected, the ambient temperature of the area where the extinguisher will be located, and other factors that may dictate the selection of a particular type of extinguisher. CLASSIFICATION Generally, fire extinguishers are selected based on the hazard(s) they are intended to protect. Classifications have been established to categorize what type of extinguishing agent is best suited for the fire hazard. These classifications are A, B, C, D, and K. A fire extinguisher assigned a Class A classification is suitable for use on ordinary combustibles; wood, paper, cloth, rubber, and many of the plastics. The B classification is intended for use on flammable liquids, combustible liquids, petroleum greases, oils, oil-based paints, solvents, alcohols, and flammable gases. Class C extinguishers are for use on fires involving energized electrical equipment. For fires involving combustible metals (magnesium, lithium, zirconium, etc.), Class D extinguishers are best to use. An extinguisher designated Class K best protects cooking appliances that utilize cooking media such as vegetable oils and animal fats. RATING Along with the classification, the numerical rating of an extinguisher is an important factor in the proper selection of an extinguisher. The rating is a measure of the extinguishing potential of the fire extinguisher and is developed on the basis of comparative fire tests (Reference UL 711, Standard for Rating and Testing of Fire Extinguishers). Only the Class A and Class B classifications carry numerical ratings. Basically, the higher the number associated with the classification letter, the larger the fire the extinguisher has the potential to put out. Please refer to NFPA 10 when determining the rating necessary for the floor area requiring protection. There are no numerical ratings associated with Class C, D, or K classifications. Comparative fire tests are not conducted. In the case of Class C, the electrical nonconducting characteristics of the agent are verified, not the extinguishing potential. For Class D, only the amount of agent and application method needed to control a metal fire of a certain size and type is tested. And for Class K, the fire extinguishing characteristics of the extinguisher have only been determined for a single size fire source. In the typical rating of an extinguisher, for example 3A-40B:C, the 3 and the 40 indicate the extinguishing potential of the unit for a Class A and Class B fire respectively. The C indicates that the extinguishing agent will not conduct electricity, preventing shock to the user if used on energized electrical equipment. On the following page is a reference chart with the basic rating parameters for extinguishers. SUMMARY To provide the best protection of life and property from the destructive force of fire, it is critical that the proper fire extinguisher selection be made. The Classification and Rating of an extinguisher are vital pieces of information for making that selection. Using NFPA 10 for guidance, matching the right fire extinguisher to the potential hazard, providing a sufficient number of extinguishers for the area to be protected, locating the extinguishers for maximum visibility and accessibility, and personnel trained in the use and maintenance of the extinguisher will significantly lessen the risk of loss.

5 BuckeyeCOMPLETE:Layout 1 5/24/07 4:07 PM Page 5 EXTINGUISHER PLACEMENT AND RATING REFERENCE CHARTS Placement/Accessibility Of Extinguisher MAXIMUM TRAVEL DISTANCE CLASS A FIRE HAZARD 75 Feet Maximum area that one extinguisher can protect and meet the 75 rule = 11,250 sq. ft. CLASS B FIRE HAZARD 50 Feet Maximum area that one extinguisher can protect and meet the 50 rule = 5000 sq. ft. CLASS C FIRE HAZARD In accordance with the Class A or B hazard it is protecting CLASS D FIRE HAZARD 75 Feet CLASS K FIRE HAZARD 30 Feet Maximum area that one extinguisher can protect and meet the 30 rule = 1800 sq. ft. Basic Extinguisher Rating Parameters Numerical Rating ORDINARY COMBUSTIBLES Wood Panel Fire Test Class A Fires (Wood, Paper, Cloth, Rubber) Wood Crib Fire Test FLAMMABLE LIQUIDS Class B Fires (Gasoline, Oil, Paints, Solvents, Propane) Numerical Rating Minimum Discharge Required Fire Test Pan Size (expert) Estimated Novice Capability Overall Dims. No. of Trade Size of (inches) Members Members (inches) 1A 8 x 8 20 x 20 x x 2 x 20 2B 8 Sec 5 sq ft 5 sq ft 2A 10 x x 25 x x 2 x 25 5B 8* Sec 12.5 sq ft 10 sq ft 3A 12 x x 29 x x 2 x 29 10B 8* Sec 25 sq ft 20 sq ft 4A 14 x x 32 x x 2 x 32 20B 8* sec 50 sq ft 40 sq ft 6A 17 x x 36 x x 2 x 36 40B 13 Sec 100 sq ft 60 sq ft 10A N/A 43 x 43 x x 2 x 43 60B 17Sec 150 sq ft 80 sq ft 20A N/A 55 x 55 x x 4 x 55 80B 20 Sec 200 sq ft 80 sq ft 30A N/A 64 x 64 x x 4 x B 26Sec 300 sq ft 120 sq ft 40A N/A 69 x 69 x x 4 x B 31 Sec 400 sq ft 160 sq ft *13 Seconds with an A rating ENERGIZED ELECTRICAL Class C Fires (Computers, Electrical Panels, Transformers) NO FIRE TEST Extinguishing agent is tested for electrical nonconductivity. If nonconductive, the C symbol is added to the existing classification. No numerical rating is given for Class C COOKING MEDIA Class K Fires (Cooking Appliances) Fire Test Fryer Size 18 x24 x18 Deep Fat Fryer No numerical rating is given for Class K Discharge Time Approx. 60 Seconds There are three general classifications of hazard areas- low, ordinary, and extra. Minimum rating required for low or ordinary hazard areas is 2A. Minimum rating for extra hazard areas is 4A. Maximum floor area that can be protected per unit of A is 3,000 sq. ft. for low hazard. Maximum floor area that can be protected per unit of A is 1,500 sq. ft. for ordinary hazard. Maximum floor area that can be protected per unit of A is 1,000 sq. ft. for extra hazard. To determine the rating necessary for proper protection, divide the total sq. ft. by the unit of A for the hazard. Example: An extinguisher is needed to protect an office area (low hazard) that measures 10,500 sq. ft. Total sq. ft. = 10,500. Unit of A for low hazard is 3,000. The rating necessary to protect the area is 10,500 3,000 = 3.5 units of A. Rounding up to the next numerical rating would mean that a 4A-rated extinguisher would be needed to protect the office. If the area were classified as extra hazard then the extinguisher would need to be rated 20A (10,500 1,000 = 10.5 units of A. Rounded up to the next numerical rating = 20A).

6 BuckeyeCOMPLETE:Layout 1 5/25/07 11:01 AM Page 6 ABC DRY CHEMICAL HAND HELD STORED PRESSURE FIRE EXTINGUISHERS FEATURES: Monoammonium Phosphate based dry chemical agent. Rated for use on A, B, and C class fires. Provides the widest, most practical range of fire protection. Rechargeable Steel cylinders with a baked-on polyester enamel coating stand up to harsh environments. Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards Optional brass valves on some units. 30 lb. unit has brass valve only TYPICAL USES: Offices, warehouses, woodworking areas, farms, general public assembly areas, and homes. The ABC extinguisher is not recommended for use on sensitive electronic equipment or aircraft structure. Model 2.5 ABC V/B 5ABC 5ABC V/B 10 TALL ABC 10S ABC 20S ABC 30S ABC Part # Alum. Valve N/A Part # Brass Valve N/A N/A Agent Capacity 2.5 lb. (1.13 kg) 5lb. (2.27 kg) 10 lb. (4.54 kg) 20 lb. (9.07 kg) 30 lb. (13.6 kg) UL Rating 1A-10B:C 3A-40B:C 4A-80B:C 4A-60B:C 20A-120B:C 20A-160B:C Discharge Time 9 sec 14 sec 22 sec 18 sec 26 sec 32 sec Range (ft/m) 9-15 / / / / Operating Pressure 100 psi (689 kpa) 195 psi (1344 kpa) Bracket Vehicle Wall Vehicle Wall USCG Approval Type B:C Size I Type A Size II Type B:C Size I Type A Size II Type B:C Size II Type A Size II Type B:C Size III Type A Size II Type B:C Size IV Ship Wt. 5.5 lbs. 10 lbs lbs lbs lbs lbs lbs. Height Width Diameter (2.5 kg) in (37.5 cm) in (12.4 cm) in (8.6 cm) (4.5 kg) (4.7 kg) in (41.6 cm) 7.25 in (18.4 cm) 4.25 in (10.8 cm) (8.3 kg) 21 in (53.3 cm) 7.75 in (19.7 cm) in (13 cm) (8.6 kg) in (42.5 cm) 8.25 in (21 cm) 6in (15.2 cm) (15.2 kg) in (53.8 cm) 8.75 in (22.2 cm) 7.5 in (19.1 cm) (23.7 kg) in (69.4 cm)

7 BuckeyeCOMPLETE:Layout 1 5/25/07 11:01 AM Page 7 STANDARD DRY CHEMICAL HAND HELD STORED PRESSURE FIRE EXTINGUISHERS FEATURES: Sodium Bicarbonate based dry chemical agent. Rated for use on B and C Class fires. Rechargeable Steel cylinder with a baked-on polyester enamel coating stands up to harsh environments. Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards. TYPICAL USES: Kitchens, garages, boats, vehicles, and extinguisher use training. The Standard extinguisher is not recommended for use on sensitive electronic equipment. Model 2.5 STD V/B 5.5 STD 5.5 STD V/B 10 STD 20S STD Part # Aluminum Valve Agent 2.5 lbs. 5.5 lbs. 10 lbs. 20 lbs. Capacity (1.13 kg) (2.50 kg) (4.54 kg) (9.07 kg) UL Rating 10 B:C 40 B:C 120 B:C Discharge Time 9 seconds 14 seconds 26 seconds Range 9-15 ft ( m) ft ( m) ft ( m) Operating Pressure 100 psi (689 kpa) 195 psi (1344 kpa) Bracket Vehicle Wall Vehicle Wall USCG Approval Type B:C Size I Type B:C Size II Type B:C Size III Ship Wt. 5.5 lbs. (2.5 kg) 10.5 lbs. (4.8 kg) lbs. (4.9 kg) lbs. (8.3 kg) 33.5 lbs. (15.2 kg) Height in (37.5 cm) in (41.6 cm) 21 in (53.3 cm) in (53.8 cm) Width in (12.4 cm) 7.25 in (18.4 cm) 7.75 in (19.7 cm) 8.75 in (22.2 cm) Diameter in (8.6 cm) 4.25 in (10.8 cm) in (13 cm) 7.5 in (19.1 cm)

8 BuckeyeCOMPLETE:Layout 1 5/25/07 11:01 AM Page 8 PURPLE K DRY CHEMICAL HAND HELD STORED PRESSURE FIRE EXTINGUISHERS FEATURES: Potassium Bicarbonate based dry chemical agent. Rated for use on B, and C class fires. Most effective dry chemical agent for Class B fires Rechargeable Steel cylinder with a baked-on polyester enamel coating stands up to harsh environments. Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards Optional brass valves on some units. 30 lb. unit has brass valve exclusively. TYPICAL USES: Garages, service bays, boats, vehicles, fuel storage and transfer areas. The Purple K extinguisher is not recommended for use on sensitive electronic equipment. Model 2.5 PK V/B 5PK 5PKV/B 10 PK 20S PK 30S PK Part # N/A Alum. Valve Part # N/A N/A N/A N/A Brass Valve Agent Capacity 2.5 lbs (1.13 kg) 5lbs. (2.27 kg) 10 lbs (4.54 kg) 20 lbs. (9.07 kg) 30 lbs. (13.6 kg) UL Rating 10 B:C 20 B:C 80 B:C 120 B:C 160 B:C Discharge Time 9 seconds 22 seconds 26 seconds 32 seconds Range 9-15 ft ( m) ft ( m) ft ( m) ft ( m) Operating Pressure 100 psi (689 kpa) 195 psi (1344 kpa) Bracket Vehicle Wall Vehicle Wall USCG Type B:C Size I Type B:C Size II Type B:C Size III Type B:C Size IV Approval Ship Wt. 5.5 lbs (2.49 kg) 10 lbs. (4.5 kg) lbs. (4.6 kg) lbs. (8.3 kg) 33.5 lbs. (15.2 kg) lbs. (23.7 kg) Height in (37.5 cm) in (41.6 cm) 21 in (53.3 cm) in (53.8 cm) lbs. (69.4 cm) Width in (12.4 cm) 7.25 in (18.4 cm) 7.75 in (19.7 cm) 8.75 in (22.2 cm) Diameter in (8.6 cm) 4.25 in (10.8 cm) in (13 cm) 7.5 in (19.1 cm)

9 BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 9 HALOTRON HAND HELD AND WHEELED STORED PRESSURE FIRE EXTINGUISHERS FEATURES: Residue-free Hydrochlorofluorocarbon gas agent pressurized with argon. Excellent replacement for Halon 1211 extinguishers. Rechargeable steel cylinders with baked-on polyester enamel coating that stands up to harsh environments. Wheeled units have DOT approved 4BW240 cylinders, rugged frames, and semi-pneumatic tires. All units are manufactured to ANSI/UL 2129 and ANSI/UL 711 Standards. Optional chrome-plated brass valves on some units (standard on Wheeled Extinguishers). TYPICAL USES: Computer rooms, telephone switch rooms, data storage areas, boats, and flight lines. Model 2.5F 2.5F 2.5H 2.5H 5F 5F V/B 5H 5H V/B V/B V/B Part # Alum. Valve Part # Brass Valve Not Available Agent Capacity 2.5 lbs (1.13 kg) 5 lbs. (2.27 kg) 5.5 lbs. (2.49 kg) 11 lbs. (5 kg) 15.5 lbs. (7.03 kg) UL Rating 2B:C 5B:C 1A-10B:C 2A-10B:C Discharge Time 9 seconds 13 seconds Range 6-10 ft (1.8-3 m) 9-15 ft ( m) ft ( m) Operating Pressure 100 psi (689 kpa) 125 psi (862 kpa) Bracket Wall Vehicle Wall Vehicle Wall Vehicle Wall Vehicle Wall USCG Approval Not Applicable Type B:C Size I Type B:C Size II Ship Wt lbs (2.4 kg) 5.5 lbs. (2.49 kg) 5.75 lbs (2.6 kg) 9.25 lbs. (4.2 kg) 9.5 lbs. (4.3kg) 10 lbs. (4.5 kg) lbs. (4.7 kg) lbs. (9.6 kg) lbs. (11.7 kg) Height in (34 cm) in (41.6 cm) 17.5 in (44.5 cm) Width in (14.3 cm) 6.75 in (17.1 cm) 6.5 in (16.5 cm) 7.25 in (18.4 cm) 6.5 in (16.5 cm) 7.25 in (18.4 cm) in (21.9 cm) Diameter in (8.6 cm) 4.25 in (10.8 cm) 7 in (17.8 cm) Wheeled Extinguishers Model Part # Capacity UL Rating Discharge Time Range Unit Height x Width x Depth W lbs 4A-40B:C ft 50 x 24 x 41.5 in (29.5 kg) seconds ( m) (127 x 61 x 105 cm) W lbs 10A-80B:C ft 62 x 24 x 41.5 in (68 kg) seconds ( m) (157.5 x61 x 105 cm) Hose Diameter x Length.75 in x 25 ft (1.9 cm x 7.6 m) 1inx40ft (2.5 cm x 12.2 m) Ship Weight 300 lbs (136 kg) 480 lbs (218 kg)

10 BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 10 CARBON DIOXIDE HAND-HELD AND WHEELED FIRE EXTINGUISHERS FEATURES: Residue-free carbon dioxide gas extinguishing agent. Hand-held units use aluminum cylinders with a baked-on polyester enamel coating to withstand harsh environments. Wheeled units are constructed with spun steel cylinders, rugged frames, and pneumatic tires and are designed to be easily operated by one person. All units manufactured to ANSI/UL 154 and ANSI/UL 711 Standards and use DOT compliant cylinders. Plated brass valves on both hand-held and wheeled units. Optional tow loops offered on the wheeled extinguishers. TYPICAL USES: Refineries, shipboard, laboratories, construction sites, chemical plants, and manufacturing facilities. Hand-Held Extinguishers Model 5CD 10CD 15CD 20CD Part Number Agent Capacity 5 lbs. (2.27 kg) 10 lbs. (4.54 kg) 15 lbs. (6.80 kg) 20 lbs. (9.07 kg) UL Rating 5B:C 10B:C Discharge Time 8 seconds 10 seconds 15 seconds 20 seconds Range 4-8 ft ( m) Bracket Wall USCG Approval Type B:C Size I Type B:C Size II Ship Wt lbs. (6.3 kg) lbs. (12.6 kg) lbs. (17.1 kg) 49.0 lbs. (22.2 kg) Height in (44.1 cm) in (50.2 cm) in. (67 cm) in (68.2 cm) Width 8.25 in (21 cm) 12 in (30.5 cm) 13 in (33 cm) Diameter 5.25 in (13.3 cm) 6.89 in (17.5 cm) 8 in (20.3 cm) Model Part # Capacity UL Rating C-50-SE lbs. (22.68 kg) C-100-SE lbs. 20B:C (45.36 kg) Wheeled Extinguishers Discharge Range Unit Time Height x Width x Depth x 30 x 21 in seconds 15 ft (152.4 x 76.2 x 53.3 cm) 80 (4.6m) 65 x 30 x 21 in seconds (165.1 x 76.2 x 53.3 cm) Hose Dia x Length 1inx15ft (2.5 cm x 4.56 m) 1inx40ft (2.5 cm x 12.2 m) Ship Weight 250 lbs. (113.4 kg) 390 lbs. (176.9 kg)

11 BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 11 AUTOMATIC SPOT PROTECTION FEATURES: Designed to provide supplemental protection suitable for some local and total flood applications. Two mount styles available, charged with multipurpose dry chemical (ABC) or clean agent Halotron. The cylinders are constructed and tested to the same engineering standards as our portable extinguishers. These units are not Underwriters Laboratories Listed and are not intended for use in lieu of an engineered system. They are not to be multiple mounted. VERTICAL MOUNT STYLE Agent Multipurpose ABC Dry Chemical Halotron Part No Capacity (lb./kg) 2.5 lbs/ 1.13 kg 5 lbs/ 2.3 kg 10 lbs/ 4.5 kg 20 lbs/ 9.1 kg 18 lbs/ 8.2 kg 25 lbs/ 11.3 kg Ship Wt. (lb./kg) 4 lbs/ 1.8 kg 11 lbs/ 5.0 kg 19 lbs/ 8.6 kg 36 lbs/ 16.3 kg 29 lbs/ 13.2 kg 42 lbs/ 19.0 kg Operating Pressure 100 psi (689 kpa) 195 psi (1344 kpa) 100 psi (689 kpa) Length in in in in in in Diameter in 4.25 in 6.0 in 7.5 in 7.0 in 7.5 in Max Total Flood- Volume 120 cu ft 180 cu ft 1300 cu ft 2184 cu ft 500 cu ft 700 cu ft Max Total Flood- Height above Hazard 7.5 ft 13 ft 14 ft 8 ft 10 ft Local Application Coverage Areas 4ftx4ft 4ftx6ft 10 ft x 10 ft 12 ft x 13 ft 4ftx4ft 6ftx6ft Max Local Application- Height Above Hazard = 4 feet for all models HORIZONTAL MOUNT STYLE Agent Multipurpose ABC dry chemical Halotron Part No Capacity (lb./kg) 2.5 lbs/ 1.13 kg 5 lbs/ 2.3 kg 10 lbs/ 4.5 kg 20 lbs/ 9.1 kg 18 lbs/ 8.2 kg 25 lbs/11.3 kg Ship Wt. (lb./kg) 4 lbs/ 1.8 kg 11 lbs/ 5.0 kg 19 lbs/ 8.6 kg 36 lbs/ 16.3 kg 29 lbs/ 13.2 kg 42 lbs/ 19.0 kg Operating Pressure 100 psi (689 kpa) 195 psi (1344 kpa) 100 psi (689 kpa) Length in in in in in in Diameter in 4.25 in in 7.5 in 7.0 in 7.5 in Max Total Flood- Volume 120 cu ft 180 cu ft 1300 cu ft 2184 cu ft 500 cu ft 700 cu ft Max Total Flood- Height above Hazard 7.5 ft 13 ft 14 ft 8 ft 10 ft Local Application Coverage Areas 4ftx4ft 4ftx6ft 10 ft x 10 ft 12 ft x 13 ft 4ftx4ft 6ftx6ft Mounting Bracket Max Local Application- Height Above Hazard = 4 feet for all models

12 BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 12 DRY CHEMICAL WHEELED FIRE EXTINGUISHERS FEATURES: Three choices in dry chemical agents are available to suit your particular fire protection needs: Monoammonium Phosphate (ABC), Sodium Bicarbonate (Standard), and Potassium Bicarbonate (Purple K). The ABC extinguisher is rated for use on A, B, and C class fires, providing the widest, most practical range of fire protection. The Standard and Purple K extinguishers are rated for use on B:C classes of fires. Designed for one-man operation. Easily transported through doorways and over rough terrain. All models are also available as stationary units. Every model is rechargeable. Rugged steel cylinders and frames with baked-on polyester enamel coatings stand up to harsh environments. Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards. Plated brass cylinder valves and hose valve assemblies. All pressurized cylinders are DOT approved. Extinguishers part numbered 30010, 30110, 30030, 30310, & are USCG approved. TYPICAL USES: Offshore rigs, ship docks, refineries, chemical plants, aircraft ramps, remote construction sites, large laboratories, processing plants, storage and loading areas. These extinguishers are not recommended for use on sensitive electronic equipment. WHEELED EXTINGUISHER PHYSICAL ATTRIBUTES MODEL PART NO. SHIP WEIGHT HEIGHT WIDTH DEPTH HOSE LENGTH x DIA A-50-SP lbs. 47 inches 24 inches 26.5 inches 25 ft. x.50 in K-50-SP (88 kg) (119 cm) (61 cm) (67 cm) (7.6 m x 1.3 cm) A-150-SP lbs. 51 inches 26 inches 38 inches K-150-SP (156 kg) (128 cm) (66 cm) (96.5 cm) A-150-RG lbs. K-150-RG (188 kg) 50 inches 24 inches 42 inches S-150-RG lbs. (127 cm) (61 cm) (105 cm) (199 kg) A-150-RG 31140* 31150** 448 lbs. 50 ft x.75 in K-150-RG 31340* (204 kg) 55 inches 32 inches 46 inches (15.2 m x 1.9 cm) 31350** (139 cm) (81.3 cm) (117 cm) S-150-RG 31240* 473 lbs ** (215 kg) A-150-PT lbs. K-150-PT (157 kg) 50 inches 24 inches 42 inches S-150-PT lbs. (127 cm) (61 cm) (105 cm) (168 kg) A-350-RG 32120* 32140** 810 lbs. K-350-RG 32320* (368 kg) 32340** 32220* 860 lbs. S-350-RG 32240** (391 kg) 32110* 58 inches 36 inches 48 inches 50 ft x 1 in A-350-PT (147 cm) (91.4 cm) (122 cm) (15.2 m x 2.5 cm) 32130** 700 lbs. K-350-PT 32310* (318 kg) 32330** S-350-PT 32210* 750 lbs ** (341 kg) WHEEL DIAMETER 12.3 x 3.5 in (31.3 x 8.9 cm) 16 x 4 in (40.6 x 10.2 cm) 36x2.5in (91.4 x 6.4 cm) * Steel Wheels ** Steel wheels with rubber tread 16 x 4 in (40.6 x 10.2 cm) 36x2.5in (91.4 x 6.4 cm) * Steel Wheels ** Steel wheels with rubber tread

13 BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 13 ABC WHEELED EXTINGHUISHER PERFORMANCE SPECIFICATIONS MODEL PART NO. AGENT CAPACITY UL RATING DISCHARGE TIME A-50-SP lbs. (22.7 kg) 30A-160B:C 35 seconds A-150-SP seconds A-150-RG lbs. 40A-240B:C 43 seconds (56.7 kg) A-150-PT seconds A-350-RG 53 seconds lbs. 40A-320B:C (136 kg) A-350-PT 57 seconds PURPLE K WHEELED EXTINGHUISHER PERFORMANCE SPECIFICATIONS MODEL PART NO. AGENT CAPACITY UL RATING DISCHARGE TIME K-50-SP lbs. (22.7 kg) 160 B:C 34 seconds K-150-SP seconds K-150-RG lbs (56.7 kg) 57 seconds K-150-PT seconds 320B:C K-350-RG 56 seconds lbs (136 kg) K-350-PT seconds DISCHARGE RANGE ft ( m) ft ( m) DISCHARGE RANGE ft ( m) ft ( m) STANDARD WHEELED EXTINGHUISHER PERFORMANCE SPECIFICATIONS MODEL PART NO. AGENT CAPACITY UL RATING DISCHARGE TIME S-150-RG lbs. 240B:C 48 seconds (68 kg) S-150-PT seconds S-350-RG lbs. 59 seconds (159 kg) 320B:C S-350-PT seconds DISCHARGE RANGE ft ( m)

14 BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 14 SPECIALTY FIRE EXTINGUISHERS WET CHEMICAL CLASS K Contains a blend of Potassium Acetate and Potassium Citrate that is extremely effective in suppressing high temperature fires fueled by the unsaturated cooking oils used in today s restaurant appliances. The agent is applied by a misting discharge nozzle that prevents the splashing and spreading of the oils. This extinguisher is designed to complement existing pre-engineered hood systems. Also carries an A Rating. Manufactured to ANSI/UL 8 and ANSI/UL 711 Standards. Model WC-6 Liter Part # Agent Capacity 6 Liter (1.59 gallons) UL Rating 1-A:K (Tested to extinguish one 18 X 24 fryer) Discharge Time 54 seconds Operating Pressure 100 psi (689 kpa) Bracket Wall Ship Wt. 22 lbs. (10 kg) Height inches (48.9 cm) Width (including hose) 9 inches (22.9 cm) Cylinder Diameter 7 inches (17.8 cm) Construction Stainless steel cylinder with plated brass valve WATER Uses water as the extinguishing agent. This economical and environmentally friendly extinguisher is ideal for schools, theaters, retail storerooms, and anywhere Class A hazards exist. Manufactured to ANSI/UL 8 and ANSI/UL 711 Standards. Model 500 Part # Agent Capacity 2.5 gallon (9.6 liters) UL Rating 2A Discharge Time 50 seconds Operating Pressure 100 psi (689 kpa) Bracket Wall Ship Wt. (empty) 7.75 lbs. (3.5 kg) Height 24.5 inches (62.2 cm) Width (including hose) 9 inches (22.9 cm) Cylinder Diameter 7 inches (17.8 cm) Construction Stainless steel cylinder with plated brass valve

15 BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 15 SPECIALTY FIRE EXTINGUISHERS WATER MIST Uses deionized water as the extinguishing agent. The unique misting nozzle creates a fine water spray that improves the cooling and soaking characteristics of the agent and limits the scattering of burning material. This extinguisher is the right choice for Class A fires where there is a potential for Class C (electrical) safety hazards. Ideal for hospitals, clean rooms, and telecom facilities. The non-magnetic properties of the extinguisher make it perfect for use in proximity to MRI equipment. Manufactured to ANSI/UL 8 and ANSI/UL 711 Standards. Model WM250 Part # Agent Capacity 2.5 gallon (9.6 liters) UL Rating 2A:C Discharge Time 73 seconds Operating Pressure 100 psi (689 kpa) Bracket Wall Ship Wt lbs. (13.4 kg) Height 28 inches (71.1 cm) Width (including hose) 14 in (35.6 cm) Cylinder Diameter 7 inches (17.8 cm) Construction Stainless steel cylinder with plated brass valve COMBUSTIBLE METALS CLASS D Specially designed for use on combustible metals fires, this extinguisher features a discharge assembly that keeps the operator at a safe distance while providing accurate application of the agent on the fire. From the heat of the fire, the sodium chloride based agent forms a crust to exclude air from the burning material. Manufactured to Factory Mutual standards. Model 30D Part # Agent Capacity 30 lbs. (13.6 kg) FM Rating D Discharge Time 28 seconds Operating Pressure 195 psi (1344 kpa) Bracket Wall Ship Wt. 55 lbs. ( kg) Height (with hose) 33 inches (83.8 cm) Width (with hose) 16 inches (40.6 cm) Cylinder Diameter 8 inches (20.3 cm) Construction Steel Cylinder

16 BuckeyeCOMPLETE:Layout 1 5/24/07 4:08 PM Page 16 Buckeye Kitchen Mister UL 300 Restaurant Fire Suppression System Protect Your Business With The Best! Discharge Nozzles All five (5) Kitchen Mister nozzles come equipped with a color identification band, red, blue, green, white, and yellow. This allows for easy identification of the nozzle even when it s installed in difficult locations such as a duct or plenum area. The nozzle is also stamped with its Model Number. System Releasing Module Protecting the modern commercial kitchen from the ever present danger of fire is the reason Buckeye Fire Equipment designed the Kitchen Mister Fire System. Utilizing state of the art misting technology, the Kitchen Mister System extinguishes potentially deadly kitchen fires quicker and more effectively than any other kitchen system ever developed, period. The modern commercial kitchen, with its open flames, hot surfaces, and grease laden environment combine all the elements necessary for a fire. Extinguishing fires quickly, before they can spread, is the best way to limit fire damage and get your operation back in business. Don t Take Chances, Demand The Best! Simple is Better The constant changes and complicated requirements of most restaurant cooking systems have made design and installation errors a concern for Fire Equipment Distributors everywhere. Obviously, a simple system design reduces the possibility of design and installation errors. At Buckeye we ve listened to these concerns and understand that simple is better. One look at the Kitchen Mister and you can see what a difference common sense makes: System Cylinders The System Releasing Module has been designed with a viewing window to assure that the actuation cartridge has been properly installed and to see the date written on the cartridge. It also includes high quality ratchets that allow the gas valve to be opened and tested from the SRM. The unit can be mounted directly on a cylinder or can be mounted remotely. It can actuate up to five (5) agent cylinders and does not require a bracket for wall mounting. Buckeye Shielded Cable The Kitchen Mister Shielded Cable Interface is used to connect Buckeye Shielded Cable to any standard 1/2 conduit connection device. The use of Buckeye Shielded Cable (Patent Pending) instead of conduit and corner pulleys for connecting the gas valve, remote pull station, and fusible link line to the Systems Releasing Module reduces installation time by up to 50%. Advanced Automatic Detection The Models BFR-5, BFR-10, BFR-15, and BFR-20 cylinders are designated by flow point capacity (so the BFR- 5 supports five (5) flow points and so on) instead of the amount of agent they hold. Recharge is available in 5 and 10 flow point containers so there s never a chance of error. The Buckeye Kitchen Mister System uses reliable Globe ML style fusible links for automatic detection. However, with the Kitchen Mister System no conduit and only one bracket is required in the entire plenum area. Just bring the cable into the plenum through an approved hood penetration, install a terminal bracket on the far end of the hood, and attach the cable. The links are attached directly to the cable without using conduit or brackets, making them quick to install and easy to move. Fusible Link Holders are also available if a continuous fusible link line is desired.

17 BuckeyeCOMPLETE:Layout 1 5/24/07 4:08 PM Page 17 FOAM CONCENTRATES AND EQUIPMENT FEATURES and SERVICES: The widest selection of earth-friendly fire fighting foam concentrates in the industry. Independent tests have shown Buckeye foam concentrates to be superior in quality and performance. Wide array of foam producing hardware and components designed to maximize foam effectiveness. Staff of experienced sales technicians to help you choose the right foam, application equipment, and design for your foam system. Buckeye Fire Equipment can provide assistance for system testing/maintenance and emergency repair service. In-house laboratory staffed with knowledgeable quality specialists to perform analysis of both Buckeye and competitor foams as required by NFPA 11 and other foam codes. FOAM CONCENTRATES Part Number Foam Concentrate Listing/Approval BFC-1.1 Platinum 1% AFFF Underwriters Laboratories BFC-3.1 Platinum 3% AFFF Underwriters Laboratories BFC-6.1 Platinum 6% AFFF Underwriters Laboratories BFC-33.1 Platinum 3%x3% AR-AFFF Underwriters Laboratories BFC-36.1 Platinum 3%x6% AR-AFFF Underwriters Laboratories BFC-3LT 3% Low Temperature AFFF Buckeye Quality Assurance BFC-36LT 3%-6% Low Temperature AR-AFFF Buckeye Quality Assurance BFC-CA.1 Platinum Class A USDA Forest Service QPL BFC-HX 2.2% High-Expansion Underwriters Laboratories BFC-3MS 3% Mil Spec AFFF U.S. Navy QPL BFC-3P 3% Protein U.K. Min Def BFC-6P 6% Protein U.K. Min Def BFC-3FP 3% Fluoroprotein Underwriters Laboratories BFC-6FP 6% Fluoroprotein Underwriters Laboratories BFC-BE Bug-Eye 3% AR-AFFF Underwriters Laboratories BFC-VF Virtual Foam Buckeye Quality Assurance FOAM EQUIPMENT Buckeye Fire Equipment manufactures a complete line of components that work in conjunction with the foam concentrates to make an unbeatable fire-fighting combination. The selection includes bladder tanks, pump skids, proportioners, eductors, monitors, foam chambers, foam makers, high expansion generators, foam carts, and handline nozzles. Many of the components can be customized to provide optimal protection for your unique situation. All foam system components are precision made from rugged materials to provide years of dependable service. Whether it s a complex engineered system or portable equipment, Buckeye Fire Equipment has the components you need to protect your valuable assets.

18 BuckeyeCOMPLETE:Layout 1 5/25/07 11:03 AM Page 18 MOUNTING HARDWARE Buckeye Fire Equipment manufactures strong and durable mounting hardware for all of our portable fire extinguishers. The charts below show the corresponding mounting hardware for the extinguishers. MARINE/VEHICLE BRACKETS Part No. Model Typical Extinguisher Sizes Used For Reference Diameter A-2 All 2.5 lb. dry chemical and Halotron in A-6 All 5 lb. & 5.5 lb. dry chemical and Halotron 4.25 in B-6 All 5 lb. & 5.5 lb. dry chemical and Halotron 4.25 in B Tall dry chemical in Tall dry chemical and 5 lb. CO² 5.0 in in lb. & 15 lb. CO², 11 lb. & 15 lb. Halotron 6.5 in in S lb. and 30S lb. dry chemical, 20 lb. CO², Class D 7.0 in. 8.0 in S dry chemical 6.0 in in. WALL HOOKS Part No. Typical Extinguisher Sizes Used For Reference Diameter lb., 5 lb., and 5.5 lb. dry chemical and Halotron 3.25 in in Tall & 5 lb. CO in. 5.5 in Short dry chemical 5.0 in. 6.5 in Short & 30 Short dry chemical, 10 & 15 lb. CO2, 6.75 in. 7.5 in. and 11 & 15 lb. Halotron lb. CO2 7.5 in. 8.0 in Wet Chemical and Water 7.0 in (Stainless Steel) Water Mist 7.0 in.

19 BuckeyeCOMPLETE:Layout 1 5/24/07 4:06 PM Page 19 Buckeye Fire Equipment

20 BuckeyeCOMPLETE:Layout 1 5/24/07 4:07 PM Page 20 Buckeye Fire Equipment 110 Kings Road Kings Mountain, NC Ph: Fax: Dry Chemical Portable and Wheeled Extinguishers Restaurant Fire Systems UL-300 Listed Specialty Extinguisher Class D & K Water / Water Mist For More Information Please Contact: Carbon Dioxide Portable and Wheeled Extinguishers Foam Concentrates And Hardware Halotron 1 Portable and Wheeled Extinguishers

Product Catalog. Your Source for World Class Fire Protection Equipment. Hand Held Extinguishers. Restaurant Fire Suppression Systems

Product Catalog. Your Source for World Class Fire Protection Equipment. Hand Held Extinguishers. Restaurant Fire Suppression Systems Product Catalog Your Source for World Class Fire Protection Equipment Foam Concentrates & Hardware Restaurant Fire Suppression Systems Hand Held Extinguishers Wheeled & Specialty Fire Extinguishers 1 Hand

More information

Product Catalog MADE IN THE USA

Product Catalog MADE IN THE USA Product Catalog MADE IN THE USA 1 Hand Held Fire Extinguishers Page 5-14 ABC Dry Chemical Page 5 Standard Dry Chemical Page 6 Purple K Dry Chemical Page 7 Halotron Page 8 High Flow Page 9 Heavy Duty High

More information

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop STORED PRESSURE 50, 125/150 lb. Stored Pressure These commercial stored pressure extinguishers are available in a choice of two sizes and three chemical options. The carriage design on both sizes provides

More information

Quality is Behind the Diamond

Quality is Behind the Diamond Quality is Behind the Diamond Amerex manufactures an extensive variety of hand portable and wheeled fire extinguishers, both compliance (code required) and specialty types. Specialty type extinguishers

More information

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE Worldwide Safety Services Fire Extinguisher Training D 1 Objectives Understand the combustion process and different fire classes. Understand d fire extinguisher i types, operating procedures, capabilities,

More information

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS (By authority conferred on the director of the department of licensing and regulatory affairs by sections

More information

FIRE EXTINGUISHERS & CHEMICAL

FIRE EXTINGUISHERS & CHEMICAL FIRE EXTINGUISHERS & CHEMICAL 1 8 1 FIRE EXTINGUISHERS & CHEMICAL For Offices, Warehouses, & More! Amerex ABC DRY CHEMICAL FIRE EXTINGUISHERS use a monoammonium phosphate dry chemical to insulate Class

More information

WHERE TO USE HOW TO USE

WHERE TO USE HOW TO USE WHERE TO USE Amerex manufactures an extensive variety of hand portable and wheeled fire extinguishers, both compliance (code required) and specialty types. Specialty type extinguishers are intended for

More information

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers READY FOR ACTION WHEN YOU ARE. Every year, cooking accidents, unattended candles, electrical failures, careless smoking and other incidents

More information

OPTIONAL INFORMATION PORTABLE FIRE EXTINGUISHERS SELF INSPECTION CHECKLIST

OPTIONAL INFORMATION PORTABLE FIRE EXTINGUISHERS SELF INSPECTION CHECKLIST OPTIONAL INFORMATION Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: PORTABLE FIRE EXTINGUISHERS Guidelines: This checklist covers the "Uniform Fire Code" regulations

More information

PRODUCT CATALOG FOR ALL INFORMATOIN AND REQUIREMENTS. WEB:

PRODUCT CATALOG FOR ALL INFORMATOIN AND REQUIREMENTS. WEB: PRODUCT CATALOG 2012-2013 FOR ALL INFORMATOIN AND REQUIREMENTS WEB: www.mefasco.com EMAIL: info@mefasco.com WHERE TO USE Amerex manufactures an extensive variety of hand portable and wheeled fire extinguishers,

More information

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971 INDEPENDENT FIRE EXTINGUISHER SALES & Your First Line of Defense Since 97 Suppression Sales i Installation i Service ABOUT IFESSAR In business since 97 Serve over 4000 customers Service Arkansas and Mississippi

More information

Extinguishers. Commercial Industrial High rise buildings

Extinguishers. Commercial Industrial High rise buildings Commercial Industrial High rise buildings Extinguishers Design, Supply, Installation, Testing, Commissioning, Maintenance, and Service of Firefighting and Fire Protection Systems Think fire protection......thank

More information

SUPPRESSION SALES I INSTALLATION I SERVICE

SUPPRESSION SALES I INSTALLATION I SERVICE SUPPRESSION SALES I INSTALLATION I SERVICE ABOUT FESSAR In business since 1973 Serve over 4000 customers Service Arkansas and Mississippi Trained and certified suppression technicians Technicians are Arkansas

More information

Portable Fire Extinguishers

Portable Fire Extinguishers Portable Fire Extinguishers Workbook Activities The following activities have been designed to help you. Your instructor may require you to complete some or all of these activities as a regular part of

More information

FIRE EXTINGUISHER SPACING & INSTALLATION GUIDELINES

FIRE EXTINGUISHER SPACING & INSTALLATION GUIDELINES FIRE EXTINGUISHER SPACING & INSTALLATION GUIDELINES Town of Brighton Office of the Fire Marshal October 2018 Fire Extinguisher Spacing & Installation Guidelines Scope The Fire Code of New York specifies

More information

SECURITY BLANKET Foam Fire Protection Products

SECURITY BLANKET Foam Fire Protection Products SECURITY BLANKET Foam Fire Protection Products REAL DANGERS DEMAND REAL SOLUTIONS If your business manufactures, stores, or transports flammable liquids, the thought of a devastating fire always burns

More information

PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers

PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers MODEL 5 The Model 5 has a slim design for use on vehicles and machinery where space is limited. Typical applications include small trucks,

More information

Portable Fire Extinguishers

Portable Fire Extinguishers Portable Fire Extinguishers Objectives (1 of 2) State the primary purposes of fire extinguishers. Define Class A fires. Define Class B fires. Define Class C fires. Define Class D fires. Define Class K

More information

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6 BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6 1. Purpose This policy sets forth requirements for preventing and detecting fires, sounding an alarm, and suppressing fires. Fire protection

More information

MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems

MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems ANSUL PIONEERED DRY CHEMICAL FIRE PROTECTION IN 1939, WHICH HELPED CREATE LARGE DRY CHEMICAL SYSTEMS WITH SUPERIOR FIREFIGHTING CAPABILITIES

More information

Risk Management Resources

Risk Management Resources Risk Management Resources Portable Fire Extinguishers Self-Inspection Checklist Guidelines: This checklist covers regulations issued by the U.S. Department of Labor, Occupational Safety and Health Administration

More information

Data/ Specification Sheet

Data/ Specification Sheet Data/ Specification Sheet MONARCH Dry Chemical Automotive Paint Spray Booth Fire Suppression System TM 1. Fixed temperature mechanical or thermal detectors 2. Electrical conduit protecting stainless steel

More information

PORTABLE FIRE EXTINGUISHERS. Fire Safety.

PORTABLE FIRE EXTINGUISHERS. Fire Safety. WHAT THE RATINGS MEAN: The New Zealand Standard for classifiying, rating, and performance testing of Fire Extinguishers (AS/NZ1850:1997), was introduced at the request of manufacturers, who wanted a method

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-10 44 16 (May 2015) ------------------------ Preparing Activity: NASA Superseding UFGS-10 44 16 (May 2012) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in agreement

More information

UFGS (June 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (June 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCESA / NASA UFGS-10 44 16 (May 2009) ------------------------- Preparing Activity: NASA Superseding UFGS-10 44 16 (June 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in

More information

GUILFORD COUNTY SCHOOLS

GUILFORD COUNTY SCHOOLS GUILFORD COUNTY SCHOOLS Fire Extinguisher Plan Policy In accordance with the regulations established by the United States Department of Labor pursuant to the Occupational Safety and Health Act and the

More information

Superior by Design The Kidde ADS TM FM-200 System

Superior by Design The Kidde ADS TM FM-200 System A UTC Fire & Security Company Superior by Design The Kidde ADS TM FM-200 System Engineered to Provide Exceptional Performance The Kidde ADS FM-200 System is an innovative system developed by Kidde engineers

More information

Three elements of fire. Heat Oxygen Fuel. Remove one of the three and the fire is extinguished.

Three elements of fire. Heat Oxygen Fuel. Remove one of the three and the fire is extinguished. ABC s Three elements of fire Heat Oxygen Fuel Remove one of the three and the fire is extinguished. Fires are classified based on type of fuel. Extinguishers are also classified on the type of fire they

More information

A.U.P.C.I ASOCIACIÓN URUGUAYA DE PROTECCION CONTRA INCENDIO AUPCI

A.U.P.C.I ASOCIACIÓN URUGUAYA DE PROTECCION CONTRA INCENDIO AUPCI A.U.P.C.I ASOCIACIÓN URUGUAYA DE PROTECCION CONTRA INCENDIO Foam Overview Applications Flammable Liquid Storage Tanks Diked Storage Tanks Loading Racks/Transfer Stations Closed Head Sprinkler Systems Deluge

More information

TAMUCC Fire Safety Training

TAMUCC Fire Safety Training TAMUCC Fire Safety Training TAMUCC Fire Safety Meeting Fire Chemistry, Classification, Types Fire Fighting Fire Prevention Fire Detections Fire Safety Activities TAMUCC Fire Safety Meeting Fire: A rapid

More information

A Guide for Meeting NFPA 10 Subsection

A Guide for Meeting NFPA 10 Subsection TECHNICAL BULLETIN A Guide for Meeting NFPA 10 Subsection 5.5.1.1 Extinguishers for Pressurized Flammable Liquids and Pressurized Gas Fires One Stanton Street / Marinette, WI 54143-2542, USA / +1-715-735-7411

More information

Fire, extreme heat, smoke, toxic fumes, noise, falling objects, uneven terrain, debris,

Fire, extreme heat, smoke, toxic fumes, noise, falling objects, uneven terrain, debris, Policy Sponsor: Assistant Vice President Facilities Management Approval Date: February 2010 Facilities Management Fire Extinguishers and Fighting Fires Safe Work Instructions Responsible Unit: Facilities

More information

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING THE MOST ADVANCED TECHNOLOGY FOR PROTECTING SPECIAL HAZARDS There are numerous hazards where the use of dry chemical is the best option for firefighting, and where the use of portable fire extinguishers

More information

CORE Protection Fire System Specification

CORE Protection Fire System Specification CORE Protection Fire System Specification The CORE restaurant fire suppression system is a pre-engineered, duct and plenum water spray system in conjunction with a wet chemical, cartridge-operated, regulated

More information

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code Part 1 - GENERAL 1.1 DESCRIPTION OF WORK A. Design and installation of an engineered Kidde ECS Advanced Delivery Systems (ADS), clean agent/waterless fire suppression system employing 3M Novec 1230 waterless

More information

FireIce & FireIce Shield F.A.Q.

FireIce & FireIce Shield F.A.Q. Introduction. This document is intended to provide additional information with respect to GelTech s family of FireIce and FireIce Shield products and equipment. It does not replace or supersede the respective

More information

June 2018 Safety Meeting Fire Extinguishers Part I

June 2018 Safety Meeting Fire Extinguishers Part I June 2018 Safety Meeting Fire Extinguishers Part I The portable fire extinguisher, one of the most common fire protection appliances in use today, is found in fixed facilities and on propane vehicles.

More information

Fire Control Fire Extinguisher (FC5)

Fire Control Fire Extinguisher (FC5) Fire Control Fire Extinguisher (FC5) Part number 44010 Regular use Disposable UL Rated 5-B:C D I S P O S A B L E Suitable for use on Class B (liquids & gases) and Class The Fire Control FC5 unit is status,

More information

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009 (II) 23, 25 June and 7, 9 July 2009 Organization by Co-organized by the Association of Registered Fire Service Installation contractors of Hong Kong Ltd (FSICA) Gas and Foam Suppression Systems Peter Bressington

More information

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS ANSUL Twin-Agent Fire Fighting/Securing Systems Specifications Models 450/50-B, 450/100-B, 900/100-B INDEX 1.0 GENERAL 1.1 References 1.2 Submittals 1.3 System Capabilities 1.4 Quality Control 1.5 Warranty,

More information

KITCHENShield WCK Kitchen Fire Suppression System. Advanced fire protection systems

KITCHENShield WCK Kitchen Fire Suppression System. Advanced fire protection systems WCK Kitchen Fire Suppression System With over 60 years' experience, Lehavot has long been recognized pioneer and leading provider of high quality Fire Protection systems. Incorporating the most advanced

More information

TYPES OF EXTINGUISHING AGENTS

TYPES OF EXTINGUISHING AGENTS 96 FIRE ENGINEERING S HANDBOOK FOR FIREFIGHTER I & II Fire extinguisher design and types All portable fire extinguishers use pressure to expel their extinguishing agents, but there are a few different

More information

Twin-Agent Fire Fighting/Securing Systems Specifications

Twin-Agent Fire Fighting/Securing Systems Specifications Twin-Agent Fire Fighting/Securing Systems Specifications Models 450/50, 450/100, 900/100 & 1350/200 INDEX 1.0 GENERAL 1.1 References 1.2 Submittals 1.3 System Capabilities 1.4 Quality Control 1.5 Warranty,

More information

Institute for Plasma Research Welcomes you all on

Institute for Plasma Research Welcomes you all on Institute for Plasma Research Welcomes you all on Presented By: D.V.MODI, Safety Officer, IPR Compiled by: SAFETY COMMITTEE, IPR WHAT IS FIRE? The self-sustaining process of rapid oxidation of a fuel,

More information

Foam Systems U.S. Quick Reference Guide

Foam Systems U.S. Quick Reference Guide Foam Systems U.S. Quick Reference Guide This guide is intended for general reference only. Prior to the design, layout, and/or installation of any sprinkler system, please refer to Viking s technical documentation

More information

extinguishers. extinguishers. Skills Objectives

extinguishers. extinguishers. Skills Objectives Chapter Overview With its self-contained features, transportability, ease of use, varied style, and application, the portable fire extinguisher may well be the unsung hero of fire suppression. Despite

More information

Fire Extinguisher Training

Fire Extinguisher Training Fire Extinguisher Training The Fire Triangle Fire Safety, at its most basic, is based upon the principle of keeping fuel sources and ignition sources separate. The Fire Triangle Three things must be present

More information

Agent Tanks PCL PCL PCL PCL - 600

Agent Tanks PCL PCL PCL PCL - 600 Components Pg 2-1 Agent Tanks PCL - 160 PCL - 300 PCL - 460 PCL - 600 Model No. Diameter Height to top of valve Height with control head Height to valve outlet Weight PCL - 160 8.00 in. 17.65 in. 23.50

More information

Model Policy On Portable Fire Extinguishers (Ontario Version)

Model Policy On Portable Fire Extinguishers (Ontario Version) Model Policy On Portable Fire Extinguishers (Ontario Version) Every workplace needs a policy ensuring the appropriate selection, use, storage and maintenance of fire extinguishers. OHS managers in any

More information

FIRE SUPPRESSION SYSTEM

FIRE SUPPRESSION SYSTEM FIRE SUPPRESSION SYSTEM An effective fire suppression systems work fundamentally in three ways; The corner stone has to be an efficient means of early warning/detection. Followed by either an Oxygen reduction

More information

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

S12 Fire Safety Risk Assessment H&SFS01-1 / 9 S12 Fire Safety Risk Assessment H&SFS01 Risk ratings The following risk ratings are based on two factors: The overall fire risk rating for the site The risk rating for the individual recommendations /control

More information

READY FOR CHANGE. A Guide for Meeting the NFPA Compliance Standard for Portable Fire Extinguishers

READY FOR CHANGE. A Guide for Meeting the NFPA Compliance Standard for Portable Fire Extinguishers READY FOR CHANGE A Guide for Meeting the NFPA 10-2010 Compliance Standard for Portable Fire Extinguishers THE CHALLENGES A QUICK REVIEW The NFPA 10 Standard contains many guidelines that may impact you

More information

Fire Safety. Version 1.0

Fire Safety. Version 1.0 This document is intended to provide basic safety guidelines for the Physical Plant Department at Community College of Allegheny County. The information provided in this guide may vary by site. Version

More information

Extinguisher Chemical Refill

Extinguisher Chemical Refill Halotron I Clean Agent For A, B & C Fires The most broadly tested and approved 1211 replacement product available that s safe, environmentally friendly, effective and easy-to-use! Halotron is a clean fire

More information

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection Aerosol Fire Suppression Your Choice for Special Hazard Fire Protection Maintenance Costs Over 10 Years Service call: $785/day Stat-X Dry Chemical CO2 Halocarbon Inert Gas Water Mist 0 $5,000 $10,000 $15,000

More information

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND 1. GENERAL SPECIFICATION 1.1 A pre-engineered, fixed pipe, automatic dry chemical fire suppression system shall be provided and installed for the hazard including work area, plenums and all exhaust ventilation

More information

An Overview of Extinguishing Systems for Computer Equipment

An Overview of Extinguishing Systems for Computer Equipment Risk Solutions An Overview of Extinguishing Systems for Computer Equipment Various types of automatic suppression systems are available for protecting computer equipment. This report discusses the uses

More information

TWO TIMES THE FIGHT Twin-Agent Fire Suppression Systems

TWO TIMES THE FIGHT Twin-Agent Fire Suppression Systems TWO TIMES THE FIGHT Twin-Agent Fire Suppression Systems A TOUGH SOLUTION FOR TOUGH FIRES No fire should be taken lightly. Yet, there are some that go far beyond a typical fire. These extremely hazardous

More information

The metering orifice is sized according to the type and percentage of concentrate used and is also secured with a stainless steel retaining ring)

The metering orifice is sized according to the type and percentage of concentrate used and is also secured with a stainless steel retaining ring) Legend: 1 Deluge Valve (DV-5) 2 Isolation Valve 3 Diaphragm Supply Valve 4 Manual Control Station 5 Automatic Shut-off Valve 6 Automatic Drain Valve 7 Pressure Switch 8 Water Motor Gong 9 Releasing Panel

More information

FIRE EXTINGUISHER. Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley Extinguishers

FIRE EXTINGUISHER. Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley Extinguishers FIRE EXTINGUISHER Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley U.A.E K.S.A www.nteico.com FIRE EXTINGUISHER Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley Extinguishers INDEX NTEICO

More information

A. Section Includes: Fire extinguishers and cabinets including necessary accessories.

A. Section Includes: Fire extinguishers and cabinets including necessary accessories. SECTION 10522 FIRE EXTINGUISHERS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Fire extinguishers and cabinets including necessary accessories. B. Related Sections: 1. 09900 - Painting 2. 10400 - Identifying

More information

Statement of Policy. Fire Extinguisher Use Policy #: SMS-041

Statement of Policy. Fire Extinguisher Use Policy #: SMS-041 Statement of Policy Fire Extinguisher Use Policy #: SMS-041 Controlling Office: Director of Health, Safety, Education and Training Effective Date: May 1, 2013 Applies to CAMTS: Ninth Edition 04.02.01-E

More information

E4218 Fire Extinguisher Basic Training. Leader s Guide

E4218 Fire Extinguisher Basic Training. Leader s Guide E4218 Fire Extinguisher Basic Training Leader s Guide FIRE EXTINGUISHER BASIC TRAINING This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION

More information

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System 1. GENERAL 1.1 INTENT OF SPECIFICATIONS A. This specification details the requirements for an engineered inert gas fire suppression system Model Kidde Nitrogen. These requirements, combined with good engineering

More information

Capital Projects Group Fire Extinguishers Specification

Capital Projects Group Fire Extinguishers Specification Capital Projects Group Fire Extinguishers Specification Specification 21 20 05 Revision 0 Date: August 2018 Fire Extinguishers Specification Specification 21 20 05 Publication Date: August 2018 COPYRIGHT

More information

COGEN CONSULT. Page 1 of 23

COGEN CONSULT. Page 1 of 23 KOJEN FIRE FIGHTING SYSTEMS DESIGN WE DESIGN EXECUTE - AS PER NFPA FOLLOWING SAFETIES METHODS ARE ASSENTIAL FOR INDUSTRIAL-OFFICES-COMMERCIAL-DOMESTIC INSTALLTIONS 1) GENERAL SURVEY AUDIT FOR FIRE TYPES

More information

WHAT IS FIRE? In order to have a fire, there must be three elements: Heat -- enough to make the fuel burn

WHAT IS FIRE? In order to have a fire, there must be three elements: Heat -- enough to make the fuel burn Emergency Action plan Volunteer employees with first aid and CPR training Designated meeting place First aid kit Eye wash stations Who do you contact? Fire extinguishers WHAT IS FIRE? In order to have

More information

HALOTRON I CLEAN AGENT FOR A, B & C FIRES REGULAR B:C FIRE EXTINGUISHERS PURPLE K B:C POTASSIUM BICARBONATE EXTINGUISHERS

HALOTRON I CLEAN AGENT FOR A, B & C FIRES REGULAR B:C FIRE EXTINGUISHERS PURPLE K B:C POTASSIUM BICARBONATE EXTINGUISHERS HALOTRON I CLEAN AGENT FOR A, B & C FIRES Halotron I clean fire extinguishing agent discharges as a rapidly evaporating liquid, which is non-conductive, non-corrosive, and leaves behind no residue. Determined

More information

Design & Construction Standards, Revised January

Design & Construction Standards, Revised January PART 1 GENERAL 1.01 Scope of Standard A. This standard provides general requirements of The University of Texas at Austin for fire-extinguishing systems other than water-based fire suppression systems.

More information

Purple K B:C Potassium Bicarbonate Extinguishers

Purple K B:C Potassium Bicarbonate Extinguishers Halotron I Clean Agent For A, B & C Fires Halotron I clean fire extinguishing agent discharges as a rapidly evaporating liquid, which is non-conductive, non-corrosive, and leaves behind no residue. Determined

More information

Portable Fire Extinguishers

Portable Fire Extinguishers Portable Fire Extinguishers Chapter Overview With its self-contained features, transportability, ease of use, varied style, and application, the portable fire extinguisher may well be the unsung hero of

More information

MSC Guidelines for Foam Fire Suppression Systems

MSC Guidelines for Foam Fire Suppression Systems References: S. T. Brady, CDR, Chief, Engineering Division a. 46 CFR 34.17, Tank Vessel Fixed Foam b. 46 CFR 34.20, Tank Vessel Deck Foam c. 46 CFR 76.17 Passenger Vessel Foam d. 46 CFR 95.17, Cargo Vessel

More information

D. Reference Standards (Utilize latest editions available):

D. Reference Standards (Utilize latest editions available): 1.01 Scope of Standard A. This standard provides general requirements of The Sam Houston State University for fireextinguishing systems other than water-based fire suppression systems. This document is

More information

AFEX. fire suppression systems AFEXSYSTEMS.COM

AFEX. fire suppression systems AFEXSYSTEMS.COM AFEX fire suppression systems AFEXSYSTEMS.COM ABOUT US We are heavy equipment people specializing in fire protection. AFEX is uniquely positioned to meet your fire protection needs. We have dedicated 50

More information

Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015

Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015 Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015 Fire Protection I. INTRODUCTION II. GENERAL GUIDELINES III.

More information

TECHNICAL DATA 3% AR-AFFF

TECHNICAL DATA 3% AR-AFFF June 25, 21 Foam 14a The Viking Corporation, 21 N Industrial Park Drive, Hastings MI 4958 Telephone: 269-945-951 Technical Services: 877-384-5464 Fax: 269-818-168 Email: techsvcs@vikingcorp.com 1. DESCRIPTION

More information

Extinguishers. ABC Dry Chemical Fire Extinguisher. Carbon Dioxide Fire Extinguisher. Halotron Fire Extinguisher

Extinguishers. ABC Dry Chemical Fire Extinguisher. Carbon Dioxide Fire Extinguisher. Halotron Fire Extinguisher Extinguishers ABC Dry Chemical Fire Extinguisher ABC or multi-purpose extinguishers utilize a specially fluidized siliconized mono ammonium phosphate dry chemical, it chemically insulates Class A fires

More information

FIRE AND FIRE FITTING By Mr. Prashant Sansare

FIRE AND FIRE FITTING By Mr. Prashant Sansare FIRE AND FIRE FITTING By Mr. Prashant Sansare What is mean by fire? CASE STUDY What Happened? Late one evening, a large storage tank containing a flammable liquid began to overflow. It was not detected

More information

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems DETECT-SUPPRESS-PROTECT THE INERGEN CLEAN AGENT SYSTEM FROM ANSUL INERGEN IS BETTER FOR YOUR PROPERTY Upon discharge, INERGEN instantly

More information

The development Of the new CEN standard For fire fighting foam systems EN13565 Part 2

The development Of the new CEN standard For fire fighting foam systems EN13565 Part 2 The development Of the new CEN standard For fire fighting foam systems EN13565 Part 2 Presented by: Bob Whiteley Engineering & Standards Manager Tyco Fire & Integrated Solutions Ltd Convenor CEN/TC191/WG2

More information

Tel Web: dyayan.com

Tel Web: dyayan.com 1 Our Products DYAYAN specializes in three main areas: - Manufacturing of Dry Chemical Powders - Manufacturing of Foam Concentrates - Project designing, assembly and maintenance of Fire Safety Systems.

More information

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA January 4, 2008 Sprinkler 57g 1. DESCRIPTION Viking Horizon Mirage Quick Response Large Orifice Concealed Pendent Sprinkler VK406 is a small solder link and lever spray sprinkler designed for installation

More information

Using Fire Extinguishers. Leaders Guide and Quiz

Using Fire Extinguishers. Leaders Guide and Quiz ! Using Fire Extinguishers Leaders Guide and Quiz 3578 INTRODUCTION TO THE PROGRAM Structure and Organization Information in this program is presented in a definite order so that employees will see the

More information

Foam Products ENGLISH

Foam Products ENGLISH Foam Products ENGLISH Tyco Fire & Building Products Foam Products Today s technological innovations bring chemical and material fire hazards. Our lines of sprinklers and alarm valves have an excellent

More information

& Fire Extinguisher Training

& Fire Extinguisher Training & Fire Extinguisher Training D The fire is an exothermic reaction. Ignition Flammable material + air (O2) ----------> CO 2 +H 2 O+Heat Temperature The evolved heat will further promote the reaction to

More information

Mi-T-M carries a full line of portable heaters, built in the same quality tradition you ve come to expect from us.

Mi-T-M carries a full line of portable heaters, built in the same quality tradition you ve come to expect from us. Why Mi-T-M? Mi-T-M space heaters deliver powerful instant heat right where you need it. Whether you require heat for your workshop, job site or any other outdoor setting these portable units can be moved

More information

Fire Risks in our Woodshops. Sam Altshuler January 2018

Fire Risks in our Woodshops. Sam Altshuler January 2018 Fire Risks in our Woodshops Sam Altshuler January 2018 Oops! Basics of Ignition/Combustion/Fire Necessary prerequisites: Fuel (wood, dust, flammable liquids) Oxidizer (generally air or oxygen) Sources

More information

A full range of UK manufactured portable and wheeled fire extinguishers

A full range of UK manufactured portable and wheeled fire extinguishers NORFOLK WHEELED BRITANNIA P50 BRITANNIA BLAZEX BRITANNIA MONNEX A full range of UK manufactured portable and wheeled fire extinguishers BRITANNIA MARINE EN1866 Hong Kong Fire Service Ref No. ECL/FSD/L/50R1/2012

More information

WILLIAM HICKS. MSc, CFEI, CFPS, IAAI-CFI, MIFireE, EFO, CFOD, F-IAFI. Associate Professor Eastern Kentucky University

WILLIAM HICKS. MSc, CFEI, CFPS, IAAI-CFI, MIFireE, EFO, CFOD, F-IAFI. Associate Professor Eastern Kentucky University Foam Systems WILLIAM HICKS MSc, CFEI, CFPS, IAAI-CFI, MIFireE, EFO, CFOD, F-IAFI Associate Professor Eastern Kentucky University William.Hicks@eku.edu Objectives Classify high, medium, and lowexpansion

More information

A Safe Workplace A Workplace Safety and Health Manual for Your Community Section: II-B Subject:

A Safe Workplace A Workplace Safety and Health Manual for Your Community Section: II-B Subject: Page 1 of 13 The Manitoba Workplace Safety and Health Act and Regulations, section 7.4(5) states "a workplace safety and health program must include the identification of internal and external resources,

More information

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM PART 1 GENERAL 1.01 SUMMARY SECTION 15371 KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM A. Section Includes: A complete wet chemical automatic fire suppression system for the exhaust hood, including necessary

More information

CrownFire Foam Systems

CrownFire Foam Systems CrownFire Foam Systems CrownFire offers complete systems and designs to meet NFPA, UL and FM standards... Foam Systems Applications Foam equipment and systems from CrownFire are used around the world

More information

Standard Spray concealed horizontal sidewall sprinkler VK481

Standard Spray concealed horizontal sidewall sprinkler VK481 Page 1 of 6 1. DESCRIPTION Viking Quick Response Concealed Horizontal Sidewall VK481 is a small solder link and lever spray sprinkler designed for installation on concealed pipe systems. The sprinkler

More information

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL NO. 05602 FOR AMEREX STORED PRESSURE, HAND PORTABLE DRY CHEMICAL FIRE EXTINGUISHERS. ABC (Ammonium Phosphate Base)

More information

CUTTING-EDGE PROTECTION Forestry Equipment Fire Suppression Solutions

CUTTING-EDGE PROTECTION Forestry Equipment Fire Suppression Solutions CUTTING-EDGE PROTECTION Forestry Equipment Fire Suppression Solutions PROVEN UNDER FIRE Day in, day out, the superheated engine parts of forestry equipment work within inches of flammable debris and liquids.

More information

Our products aren t always obvious, but the reasons for selecting them are. Quality is Behind the Diamond.

Our products aren t always obvious, but the reasons for selecting them are. Quality is Behind the Diamond. Our products aren t always obvious, but the reasons for selecting them are. Quality is Behind the Diamond. The attraction of a diamond can t be fully explained by its flawlessness. The long odds against

More information

Marine Fire Protection. Kidde Residential and Commercial Division 1394 South Third Street, Mebane, NC Tel

Marine Fire Protection. Kidde Residential and Commercial Division 1394 South Third Street, Mebane, NC Tel Marine Fire Protection 1 D I S P O S A B L E FIRE EXTINGUISHER Marine 210D MPWC Fire Extinguisher Part number 43 Regular use UL Rated 5-B:C Suitable for use on Class B (liquids & gases) and Class The PWC

More information

Risk Management Department. Fire Extinguishers

Risk Management Department. Fire Extinguishers Risk Management Department Fire 1 Introduction to Fire Every school facility is equipped with fire extinguishers for staff to use to suppress fires. Used properly, a fire extinguisher can be an effective

More information

FOOD PREPARATION WITHIN EXHIBITS

FOOD PREPARATION WITHIN EXHIBITS FOOD PREPARATION WITHIN EXHIBITS Whenever food is prepared within an exhibit, an Application for Food Preparation within Exhibits form should be completed and forwarded to your Convention Services Manager

More information