ELECTRONIC SOUNDER STROBE Model : AVD-C407

Size: px
Start display at page:

Download "ELECTRONIC SOUNDER STROBE Model : AVD-C407"

Transcription

1 ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an audio & visual warning device. The Housing is made of red ABS plastic, and the red light diffuser of Plexiglas, with high luminance LEDs as the light source. It has a standard clip-on base & terminal for ease of installation and mounting. The Electronic Sounder Strobe Light is designed for a wide variety of fire, security and industrial applications where reliability, efficiency and flexibility are of prime importance. TECHNICAL SPECIFICATIONS :- Operating Voltage 24VDC ±10% Current Consumption Sounder Output Operating Temp. Range Relative Humidity Ingress Protection Material of Housing Light Source Colour of Body 30 ma (During Activation) 95dB at 1m Distance -10 C to +50 C 95%, No Condensation IP gram ABS Plastic High Luminance LED Red, with Clear Light Diffuser Sounder Strobe Model : AVD-C407 Position the Body and Push to clip onto to the Mounting Base Using Clip-on Mounting Base for ease of Installation Mounting Base (Secured to Wall) 89.5 mm 62 mm 89.5 mm 74 mm 10 mm 54 mm 141 mm mm 114 mm 70 mm 14 mm 141 mm Ø4 mm Physical Dimension Mounting Base www. multron. com Version :

2 SOUNDER STROBE Model : AVD-C408W & AVD-C408R This device is designed to complement our Fire Alarm products both technically and aesthetically as an audio & visual warning device. AVD-C408W (White) The Housing is made of red ABS plastic, with a clear light diffuser lens of Plexiglas, with high luminance LEDs as the light source. It has a standard base with cable entries for ease of installation and mounting. The Electronic Sounder Strobe Light is designed for a wide variety of fire, security and industrial applications where reliability, efficiency and flexibility are of prime importance. TECHNICAL SPECIFICATIONS :- Operating Voltage 24Vdc ±15% Sounder Current 7 ma (During Activation) Strobe Current 18 ma (During Activation) Audible Alarm Output 85db at 1m (Pulsating) Flash Rate 1.64hz (0.61 second) Operating Temp. Range -10 C to +50 C Relative Humidity 95%, No Condensing Ingress Protection IP gram Material of Housing ABS Plastic Colour AVD-C408W White Body, with Clear Lens AVD-C408R Red Body, with Red Lens Features Aesthetically pleasing AVD-C408R (Red) Long-Life, Ultra-Bright LED Light Source Easy Installation with Low Maintenance Separate Input Signal for the Sounder and Strobe Suitable for both Wall or Ceiling Mounted Designed in Compliance to BS-EN54-23 Standards 64mm 70mm 11mm Ø104mm Ø72mm TYPICAL PHYSICAL DIMENSION Mounting Holes Ø5mm x 23mm Slot 24Vdc Input Signal For Sounder 24Vdc Input Signal For Strobe + _ + _ Base Termination :- Sounder Input Strobe Input , 4-6 TYPICAL TERMINATION DIAGRAM info@multron.com Version :

3 Door Alarm Unit AVD-DA200 Series The compact Door Alarm Units are with integrated Sounder / Strobe for monitoring of Doors or Exits which are normally meant to be closed. Once these Doors are opened, the alarm will be triggered. It may be used as a stand-alone unit, or several units may be interfaced with a Central Monitoring Panel, or Graphical Mimic Panel for easy supervision by the Security Personnel. AVD-DA200R AVD-DA200B Model Technical Specifications Operating Voltage Normal Current Consumption Alarm Current Consumption Sounder Output Flash Rate Operating Temperature Housing Material (Exclude Battery & Charger) Colour Of Strobe Red Lens Blue Lens 10 to 13.5 Vdc 20mA 420mA 110 db 90 flashes / min -25 C to 70 C UV Resistant ABS Approximately 280g Features :- Dual Tamper Protection for removal of the whole housing or cover With optional built-in 7.2V Rechargeable Battery Flashing LED to indicate operational status Loud Sounder with high luminance Strobe Light Selectable Exit Delay Timer and Alarm Duration Key-Switch Sounder Tamper Switch 202 Typical Physical Dimension (All Dimension in mm) www. multron. com Version :

4 N/O Alarm Contact Output Magnetic Contacts Input Trigger Incoming Power Supply : 13.5Vdc Tamper Switch Key-Switch Alarm Sounder Dip-Switch Typical Termination Diagram Optional 7.2Vdc Re-Chargeable Backup Battery Key-Switch If the Key-Switch is used, the alarm will only stop after the switch is turned to `off position. If the Key-Switch is not used, the alarm will stop once the door is closed. Alarm Delay Timer The Alarm Delay could be set by Dip-Switch 1 & 2. The Delay is to allow for a short time duration to enter or exit the doorway. Prolong opening of the door beyond the delay period will trigger the alarm. Time Switch 1 Switch 2 0 sec secs 0 I 30 secs I 0 60 secs I I Alarm Timer The alarm activation duration could be set by Dip-Switch 3 & 4. The selectable duration could be 15 min, 3 min, 1 min, or continuously as long as the door remained open. Time Switch 3 Switch 4 15 mins mins 0 I 1 min I 0 Cont I I

5 Horn Strobes Model SYS-HSW (Selectable Output) Features Mounting Plate included for compatibility with a wide range of back boxes 3 field selectable candela setting, 15, 75 and 115 Simple Rotary Dials for selection of Candela and Horn settings Built-in synchronization feature keeps strobe in sync for up to 30 minutes Strobes Listed to UL 1638, Horn Listed to UL 464 Horn settings on the Horn Strobe model include high and low volume, continuous or temporal 3 tone Round trim ring available for ceiling mount application Universal Fire Symbol is language independent 126mm 62.6mm Ø173mm 62.6mm 131mm Wall Mount Horn Strobe Model SYS-HSW Ceiling Mount Horn Strobe Model SYS-HSW c/w Optional Ceiling Trim Ring This line of devices features a wide variety of features that simplifies installation. The mounting plate allows the device to be compatible with a wide range of back box sizes. Settings for the strobe and horn are done using simple rotary switches at the back of the device. Synchronization is achieved without the use of additional modules; when powered with a filtered DC source, the strobe portion is capable of self-synchronization for 30 minutes as per NFPA 72 requirement. Three Candela options are available for the strobe when it works on 24 volts or full wave rectified power. High and low volume are options for the horn as well as continuous tone or temporal 3 output. Ceiling Mount Horn Strobe Model SYS-HSW c/w Optional Ceiling Trim Ring (Order Separately) Available accessories include a round trim ring to adapt the wall mount device for ceiling mount applications. Simply install the round ring over the square device for a perfect fit on the ceiling.

6 24Vdc Input Signal Strobe Candela Adjustment Horn Volume Adjustment Rotary Dials are provided at the back of the device for ease of adjusting the Candela & Horn www. multron. com Version :

7 SOUNDER STROBE ADDRESSABLE SOUNDER STROBE AVD-A403 CONVENTIONAL SOUNDER STROBE AVD-C403 AVD-C403 - Conventional Sounder Strobe AVD-A403 - Addressable Sounder Strobe MULTRON range of combination Electronic Sounder with Strobe Light have been designed to complement other products in our Fire Alarm equipment range both technically and aesthetically as an audio & visual warning device. The Housing is made of red ABS plastic, and the red light diffuser of Plexiglas, with high luminance LEDs as the light source. It has a standard base with cable entries & terminal block for ease of installation and mounting. The Electronic Sounder Strobe Light is designed for a wide variety of fire, security and industrial applications where reliability, efficiency and flexibility are of prime importance. TECHNICAL SPECIFICATIONS :- Model AVD-C403 Conventional Type AVD-A403 Addressable Type Operating Voltage N.A. Loop 24V Operating Current N.A. Loop 1mA (Standby) 3mA (Alarm) Power Voltage 24 V 24V Power Current Sounder Output Operating Temperature Range Relative Humidity Dimension Material of Housing Colour 0mA (Standby) 65mA (Alarm) 85 db (Alert) 94 db (Evacuate) -10 C to +50 C 95%, No Condensation 3mA (Standby) 65mA (Alarm) Diameter 110mm x Height 97.5mm Approximately 345g ABS, with light diffuser of Plexiglas Red com Version :

L-Series, Emergency Communication Devices

L-Series, Emergency Communication Devices Notification Appliances L-Series, Emergency Communication Devices Description The L-Series Emergency Communications devices and accessories combine application versatility with all of the same time-saving

More information

L-Series, Indoor Strobes and Horn Strobes

L-Series, Indoor Strobes and Horn Strobes Notification Appliances L-Series, Indoor Strobes and Horn Strobes Indoor Selectable-Output Strobes/Horn Strobes for Ceiling Applications General The L-Series audible visible notification products offer

More information

L-Series, Indoor Strobes and Horn Strobes

L-Series, Indoor Strobes and Horn Strobes Notification Appliances L-Series, Indoor Strobes and Horn Strobes Indoor Selectable-Output Horns, Strobes and Horn Strobes for Wall Applications General The L-Series audible visible notification products

More information

Conventional Fire Detection

Conventional Fire Detection SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct

More information

SELECT-A-HORN/STROBE SERIES

SELECT-A-HORN/STROBE SERIES SELECT-A-HORN/STROBE SERIES Features Description Mircom s Select-A-Strobe/Horn Series is designed to comply with the Americans with Disability Act (ADA) and meet UL standard 1971 requirements for emergency

More information

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet Table 1: Models Description Low frequency (520 Hz) horn, white housing, no FIRE marking, standard output clear strobe light Low frequency (520

More information

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E SpectrAlert Advance Description System Sensor SpectrAlert Advance offers a variety of devices designed for mass notification, including plain devices for non-fire applications, amber lens strobes and speaker

More information

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING GENERAL The VEC 25/50 is a state-of-the-art, compact, stand-alone or slave Emergency Voice Evacuation Control. The VEC 25/50 is offered in a self-contained, cost-effective design and includes a 25 Watt,

More information

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup 115 or 230VAC (90V to 264V AC range) Operating Temp: -20 to +55 C IP Rating: IP66 Weight: 5.5 kg single AC unit 7.0 kg four way AC unit Marking: Installation Requirements 1) Introduction The A131 high

More information

July 14, 1999 DF C-100.

July 14, 1999 DF C-100. www.firelite.com GENERAL The Fire Lite FIRE COMMAND 25/50 is a state-of-theart, compact, stand-alone or slave Emergency Voice Evacuation Control Panel (VECP). The FIRE COMMAND 25/50 is offered in a self-contained,

More information

Selectable Output Chimes and Chime/Strobes

Selectable Output Chimes and Chime/Strobes Selectable Output Chimes and Chime/Strobes PRELIMINARY DN-60940:A Audio/Visual Devices General System Sensor L-Series selectable-output chimes and chime/ strobes are rich with features guaranteed to cut

More information

Xenex Conventional Fire Detection & Alarm System

Xenex Conventional Fire Detection & Alarm System SECTI 4: page 1 Section 4: Xenex Conventional Fire Detection & Alarm System SECTI 4: page 3 Xenex system architecture Beam Transmitter Beam Receiver End of Line Call Point Smoke Detector Smoke Detector

More information

TrueAlert Notification Appliances

TrueAlert Notification Appliances TrueAlert Notification Appliances UL Listed; FM, CSFM and MEA (NYC) Approved* Non-Addressable Audible/Visible Notification Appliances with SmartSync Operation of Strobes and Horns Features Wall mount audible/visible

More information

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL March 30, 2000 Section: Audio/Visual Devices G-250 SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL System Sensor SpectrAlert Series strobes, horns, and combination horn/strobes are UL listed

More information

Conventional Fire Alarm System 2014 V1.2

Conventional Fire Alarm System 2014 V1.2 Conventional Fire Alarm System 2014 V1.2 Product Overview Control Panel 2 Conventional Fire Panel GST102A 2 zone Fire panel GST104A 4 zone Fire panel GST108A 8 zone Fire panel GST116A 16 zone Fire Panel

More information

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm VIMPEX Sounder Range Fire Alarms Banshee Electronic Sounders FlashDome EN 54-3 Evacuation Audible Alarm BS 5839-1 Beacons The range of sounders, beacons, sounder beacons and accessories represents the

More information

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign Features DATASHEET Connects to multiple sensing instruments One/Two Channel Device Bright solid state LED Alarm Display Audible Alert (internal and external) High reliability, fully dual redundant alarm

More information

Opal TM AV Devices. Data Sheet. Benefits

Opal TM AV Devices. Data Sheet. Benefits Opal TM AV Devices Data Sheet Notifier s Opal AV (Audio Visual) range is designed to alert building occupants of an emergency. The Opal AV range of analogue addressable, loop powered, audible and visual

More information

AP200 SERIES INTELLIGENT ALARM DEVICES

AP200 SERIES INTELLIGENT ALARM DEVICES Tech Data Sheet D0170GB Fire Detection /01 AP00 SERIES INTELLIGENT ALARM DEVICES Intelligent AP00 series alarm devices for FX fire detection system The intelligent AP00 series alarm devices are used in

More information

X10 Mini, Midi & Maxi

X10 Mini, Midi & Maxi Industrial Sounder, Sounder Beacon X0 Mini, Midi & Maxi Installation Manual EAT X0 Mini, Midi & Maxi Installation Manual (90F) Contents Overview and purpose... Product assembly... Select wiring method......

More information

FlexSQUARE Square shaped beacons

FlexSQUARE Square shaped beacons FlexSQUARE Square shaped beacons Size comparison Mini/Midi/Maxi Optical LED Permanent Light 5 LED Flashing Light 6 LED EVS 8 Your benefits The compact LED beacon is particularly versatile. With an IP67

More information

June 10, 2002 DF C S2424

June 10, 2002 DF C S2424 GENERAL www.firelite.com The Fire Lite FIRE COMMAND 25/50X is a state-of-theart Emergency Voice Evacuation Control Panel (VECP), with significant technological enhancements that set it apart from other

More information

11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies

11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies 11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies Visible Signals Agenda 1. Physics 2. Installation Considerations

More information

SP40S-D. Kingfisher Company, inc. Features: Description:

SP40S-D. Kingfisher Company, inc. Features: Description: Kingfisher Company, inc. SP40S-D Features: Multi-use applications The system can function as an evacuation system, an emergency messaging system, and an employee notification system Fire code applications

More information

Agent Release Control Panel

Agent Release Control Panel Agent Release Control Panel System Capacity Annunciators: 8 Electrical Specifications RP-2002 (FLPS-7 Power Supply): 120 VAC, 60 Hz, 3.66 amps RP-2002E (FLPS-7 Power Supply): 240 VAC, 50 Hz, 2.085 amps

More information

SAFEPATH SAFEPATH. Emergency communications system

SAFEPATH SAFEPATH. Emergency communications system SAFEPATH SAFEPATH Emergency communications system ALERiTY Integrated mass notification solutions by Eaton; designed to protect, alert and inform your most critical resources your people ALERiTY /a ler

More information

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V. Signaling Devices Acoustic Signaling Devices 28 Optical Signaling Devices 30 26 Signaling Devices Acoustic Signaling Devices Acoustic Signaling Devices MSS300-SA SG 200 DS 10 LSN/GLT GLT GLT GLT Operating

More information

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors Carbon Monoxide (CO) Detection PRODUCTS Accessories Conventional Detectors 2 Complete CO Detection The system-connected CO1224T and CO1224TR CO detectors with RealTest provide early warning by using reliable

More information

The complete conventional fire warning system

The complete conventional fire warning system The complete conventional fire warning system www.espuk.com MAG2P 2 Zone Fire Panel 2 programmable zones Active end of line monitoring and head removal 30 fire detectors per zone Unlimited number of call

More information

s Notification Appliances

s Notification Appliances s Notification Appliances Data Sheet Fire Safety Products AS & AH Audible Horn Strobe / Audible Horn Appliances Application: Indoor / Outdoor AS-MC-CW AS-MC-R AH-R AH-W Product Overview Fast installation

More information

CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information

CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information OF FIRE CS24C Colored Light Strobe/orn Series igh Candela Ceiling/Wall Mount Patent Pending Description AMSECO's UL listed Colored Light Strobe CS24C series is designed to provide audible and visual signals

More information

Opal TM AV Devices. Data Sheet. Benefits

Opal TM AV Devices. Data Sheet. Benefits Opal TM AV Devices Data Sheet Notifier s Opal AV (Audio Visual) range is designed to alert building occupants of an emergency. The Opal AV range of analogue addressable, loop powered, audible and visual

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

Celebrating YEARS Manufacturers of Visual & Audible Signalling Devices. NEW Exd

Celebrating YEARS Manufacturers of Visual & Audible Signalling Devices. NEW Exd Celebrating 15 YEARS Manufacturers of Visual & Audible Signalling Devices 1998-2013 NEW Exd INTRODUCTION MOFLASH to the world of Based in Birmingham at the heart of Great Marine FM 558977 P P P P P P P

More information

EFBW series - BiWire Ultra control panel

EFBW series - BiWire Ultra control panel 4.2 Control panels and repeater panels EFBW series - BiWire Ultra control panel Eaton s new BiWire Ultra fire detection system is unlike any other standard conventional system as the panel, conventional

More information

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances UL, ULC Listed* TrueAlert Addressable Notification Appliances Audible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output Features Individually addressed and controlled multi-tone

More information

Addressable Detectors & Bases

Addressable Detectors & Bases Edwards Signaling Catalog u Intelligent Initiating Addressable Detectors & Bases Detectors: E-PD, E-PHD, E-HD Bases: B4U, RB4U, IB4U, SB4U Overview Edwards intelligent addressable detectors are meticulously

More information

Autonomous control unit

Autonomous control unit Supersedes October 2016 Autonomous control unit Description Eaton s Autonomous Control Unit (), part of the ALERiTY integrated MNS platform, is a supervised in-building emergency communications system

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D1xC COMBINED RADIAL HORNS & STROBES For Use In Hazardous Locations - Gas 3) Ratings and Markings The D1xC1 and D1xC2 combined alarm horns and strobes comply with the following

More information

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 ANALOGUE FIRE DETECTION VIGILON COMPACT FEATURES & BENEFITS four Keep it Simple All Vigilon devices connect onto the same 2

More information

L-Series Audible Visible Notification PRODUCTS. Accessories Chimes Chime Strobes ECS and MNS Horns Horn Strobes Speakers Speakers Strobes Strobes

L-Series Audible Visible Notification PRODUCTS. Accessories Chimes Chime Strobes ECS and MNS Horns Horn Strobes Speakers Speakers Strobes Strobes L-Series Audible Visible Notification PRODUCTS Accessories Chimes Chime Strobes ECS and MNS Horns Horn Strobes Speakers Speakers Strobes Strobes 2 Simple to install, yet powerful enough to meet any requirement.

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 031703 Overview: The Altronix AL802ULADA is an extremely cost effective 8 amp voltage regulated

More information

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions TrueAlert NonAddressable, MultiCandela Notification Appliances Installation Instructions PRODUCT IDENTIFICATION REFERENCE (See Page 4 for Detailed Product Specifications) Type Mount Model Color Operation

More information

Addressable Fire Alarm Control Panel

Addressable Fire Alarm Control Panel PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT

More information

SAFEPATH Mass Notification System (SPMNS)

SAFEPATH Mass Notification System (SPMNS) Supersedes February 2016 SAFEPATH Mass Notification System (SPMNS) SP40S SPB-320 SPB-80/4 SPB-160 PS-8-LP SPMNS-MIC SP4Z-A/B Contents Page SPMNS.... 2-4 SPMNS-MIC...3 Expansion Options SAFEPATH 2-zone

More information

AP200 SERIES INTELLIGENT ALARM DEVICES

AP200 SERIES INTELLIGENT ALARM DEVICES Tech Data Sheet D017GB1 Fire Detection /01 AP00 SERIES INTELLIGENT ALARM DEVICES Intelligent AP00 series alarm devices for FX NET fire detection system The intelligent AP00 series alarm devices are used

More information

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel ACC-25/50ZST Zoned System Voice with Telephone Evacuation Control Panel General The AUDIO COMMAND CENTER 25/50 Zone System with FireFighters Telephone (ACC-25/50ZST) is a state-of-the-art Emergency Voice

More information

Conventional Audible Visual Range

Conventional Audible Visual Range Conventional Audible Visual Range Visual Devices Non-Addressable Audible Visual Devices Base Sounder Honeywell s conventional audible visual devices operate over a wide input voltage range of 9 to 33VDC

More information

>WIRELESS> ALARM SYSTEM CR200

>WIRELESS> ALARM SYSTEM CR200 intrusion >WIRELESS> ALARM SYSTEM CR200 INTRUSION HOME SECURITY CR200 is a Modern, Effective and Versatile 20-zone Household Security System. It is packed with simple Plug & Play functionality, designed

More information

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS (68.52) X June 2000 supersedes February 2000 vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS VIGILON SYSTEM ARCHITECTURE Repeat Panel Spur Manual Call Point T-breaker Alarm Sounder Max loop length 1000m

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following

More information

Industries. As a premier global manufacturing company, we believe that great brands are

Industries. As a premier global manufacturing company, we believe that great brands are JSB Fire Systems ONE COOPER Every day, thousands of people all over the world use products made by Cooper Industries. As a premier global manufacturing company, we believe that great brands are built on

More information

Field Configurable Horns and Strobes

Field Configurable Horns and Strobes EDWARDS Catalog u Strobes, Horns, Bells, Chimes LIFE SAFETY & INCIDENT MANAGEMENT Field Configurable Horns and Strobes Genesis Series ECS/MNS appliances available with clear or amber lenses. S218, S5389,

More information

Addressable and Conventional Fire Protection

Addressable and Conventional Fire Protection Addressable and Conventional Fire Protection Simply reliable F I R E P R O T E C T I O N The MAGPro and Fireline systems has been created to balance performance, reliability and aesthetics whilst being

More information

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev Installation Guide for AL800UL-ADA NAC Power Extender Rev. 090500 Overview: The Altronix AL800UL-ADA is an extremely cost effective 8 amps voltage regulated remote power supply /battery charger. The AL800UL-ADA

More information

Potter Wall Mount Select-A-Strobe

Potter Wall Mount Select-A-Strobe 104 Kenran Industrial Dr. Potter Wall Mount Select-A-Strobe SL-1224 SERIES SELECT-A-STROBE Call for additional listings 12 VDC with 15, 35 or 60 cd setting 24 VDC with 15, 35, 60, 5, 95 or 110 6 distinct

More information

30.45 Electric Release PDRP-2001

30.45 Electric Release PDRP-2001 The PDRP-2001 Fire Alarm Control Panel (FACP) is a six-zone control panel for single and dual hazard deluge and preaction applications. The FACP is compatible with conventional input devices (2-wire or

More information

Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon

Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon Technical Specification 1. Sounder Supply Voltage Range 10-60V DC Current 0.12 0.55A* (Typ. 0.5A @ 24V,

More information

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor s Data Sheet Fire Safety & Security Products 08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor AS-MC-CW AS-MC-R AH-W AH-R Product Overview

More information

good things in small packages

good things in small packages FireShield Control Panels good things in small packages life safety for small buildings and shops A perfect arrangement FireShield offers the very best conventional fire alarm technology available, with

More information

AL800ULADA. NAC Power Extender. Installation Guide

AL800ULADA. NAC Power Extender. Installation Guide AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery

More information

Fire Signalling. Signalling Solutions

Fire Signalling. Signalling Solutions Fire Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place.

More information

Consultant Specification AGILE Wireless Fire Detection System

Consultant Specification AGILE Wireless Fire Detection System Contents Scope of Work... 2 The EN54 Part 2 & 4 Fire System... 2 Standards... 2 Wireless Intelligent Photoelectric Smoke Detector Specification... 4 Wireless Intelligent Thermal Heat Detector Specification...

More information

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances UL, ULC Approved* TrueAlert Addressable Notification Appliances Audible Notification Appliances; Multi-Tone Horns with 520 Hz Output Features Individually addressed and controlled TrueAlert ES multi-tone

More information

Accessible Toilet Alarm

Accessible Toilet Alarm N C 9 5 1 D E S I G N & I N S T A L L A T I O N G U I D E Accessible Toilet Alarm This equipment must be installed and maintained by a suitably skilled and technically competent person. This document provides

More information

Addressable Loop Powered Visual Alarm Devices

Addressable Loop Powered Visual Alarm Devices Addressable Loop Powered Visual Alarm Devices About Who is? has a long and proud tradition in fire detection. Founded in Munich in 1877 as Elektrotechnische Fabrik Alois it quickly became a recognized

More information

Exit Stopper. STI-6400 Series

Exit Stopper. STI-6400 Series Exit Stopper STI-6400 Series Features Alarm helps prevent unauthorized exits/entries through doors. Easy to install. Select volume, alarm duration and delay settings. May be mounted on top, right, left

More information

Addendum for STI-6406 with Dual Access Control

Addendum for STI-6406 with Dual Access Control Addendum for STI-6406 with Dual Access Control Description: This system contains a STI-6400 with a DPDT key switch to be mounted on one side of a door or wall; and a similar looking housing, also with

More information

Conventional Smoke Detectors KFAPO

Conventional Smoke Detectors KFAPO Kingfisher Company, inc. Conventional Smoke Detectors KFAPO Features: Wide operating voltage, 9-33 VDC Advanced electronic technology Flashing LED Magnetic test switch Proven detection performance Designed

More information

The Advance You ve Been Looking For

The Advance You ve Been Looking For The Advance You ve Been Looking For The Power Behind The Products System Sensor was founded in 1984 and today is the largest manufacturer of fire detection and notification appliances in the world. More

More information

Half-Dome. the Design-Tower. Compact

Half-Dome. the Design-Tower. Compact the Design-Tower 81 Compact 82 compact signal towers Visual-audible LED signal tower system in semicircular design Modern signal tower design Available to order pre-configured or with customised tower

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

Life safety notification

Life safety notification LED Wheelock Exceder LED3 Life safety notification Meeting the latest codes with increased energy-efficiency in a compact design Wheelock Exceder LED3 Compliant, compatible, compact, and energy efficient

More information

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit PRODUCT INSTRUCTIONS Fire Door Control Panel (FDCP) Floats Rd, Wythenshawe, Manchester. M23 9WB T: 44 (0)161 945 4561 F: 44 (0)161 945 4566 Stock Code Description Doc No: PI115 00133 00134 Ellard Fire

More information

INSTRUCTION MANUAL A131 High Level Audible Warning System

INSTRUCTION MANUAL A131 High Level Audible Warning System Weight: 1.5kg single AC unit 2.9kg four way AC unit Marking: 3) Installation Requirements 1) Introduction The A131 high level audible warning system is an effective wide area warning alarm system and can

More information

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262) PATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262) NAC ETENDER SUPPLIES Installation Instructions 273 Branchport Avenue, Long Branch, NJ 07740-6899 Ph: (800) 631-2148 Fax: (732) 222-8707 Web

More information

SECTION FIRE ALARM SYSTEMS

SECTION FIRE ALARM SYSTEMS SECTION 16721 FIRE ALARM SYSTEMS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work

More information

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

CM-RQE70 PIR REQUEST TO EXIT DETECTOR Door Activation Devices CM-RQE70 PIR REQUEST TO EXIT DETECTOR THIS PACKAGE INCLUDES (1) Wiring Harness (2) #6 x 3/4" Screws (2) 3/16" Wall Plugs (6) Wire Nuts (2) 's BP7175 1. GENERAL DESCRIPTION Camden

More information

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon Sounders Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon Pg 185 186 187 188 189 190 191 Y03 1YA030207 1YA030203 1YA030205 YL030/24 A1:2002 YL030110/230 UL464 C22.2 No. M1983 BS

More information

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics by Tomar Electronics SIRENS POWER ALARM PROGRAMMABLE MULTI-SOUND INDUSTRIAL SIGNALS The POWER ALARM siren is a heavy duty industrial audible alarm designed to operate under adverse industrial conditions

More information

Genesis LED G1 Series

Genesis LED G1 Series EDWARDS Catalog u Strobes, Horns, Bells, Chimes LIFE SAFETY INCIDENT MANAGEMENT Genesis LED G1 Series Compact Notification Devices S218, S5389 7125-1657:0506 7135-1657:0502 Overview Genesis LED G1 Series

More information

Field Configurable Horns and Strobes

Field Configurable Horns and Strobes Vigilant Catalog Strobes, Horns, Bells, Chimes Field Configurable Horns and Strobes Genesis Series MNEC appliances available with clear or amber lenses. Pending Overview The Genesis line of fire alarm

More information

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue.

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue. CATALOGUE 2018 Product Catalogue Request to Exit Products Relays, Fuses & Timers CONTENTS Table of Contents Introduction: 3 Request & Emergency Egress Devices: Prox Rex 4 Press Rex 5 Em Rex 6 Smart Em

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 042010 Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).

More information

Exit Stopper. STI-6400 Series

Exit Stopper. STI-6400 Series Exit Stopper STI-6400 Series Features Alarm helps prevent unauthorized exits/entries through doors. Easy to install. Select volume, duration and immediate or 15 second delay for arming and trip. May be

More information

STANDARD FEATURES SPECIFICATIONS

STANDARD FEATURES SPECIFICATIONS MAG LOCK P/N 300768 STANDARD FEATURES Holding Force: 1500 lbs.(675 Kg.) Easy Installation: Versatile mounting bracket for new and existing doors and frames. Sensor: Built-in Hall effect crystal affected

More information

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions 1 PACKAGE CONTENTS Wiring Harness 6 Wire Nuts #6 x 3/4 Screws s BP7175 3/16 Wall Plugs Section 1: General Description Camden CM-RQE-70 Request-to-Exit

More information

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize advanced ideas advancedsolutions At System Sensor, Research and Development is more than a department. It s a way of life. Every day we work to design new products that utilize the most innovative technologies

More information

EXTINGUISHING AGENT RELEASE MODULE

EXTINGUISHING AGENT RELEASE MODULE EXTINGUISHING AGENT RELEASE MODULE Operation, Installation & Programming Manual Revision 3.00 Distributors For: 18-20 Brookhollow Ave telephone 02 8850 2888 www.firesense.com.au Baulkham Hills NSW 2153

More information

Installation Instructions

Installation Instructions Request-to-Exit Dual Technology Motion Sensor 1048889B November 2005 Copyright 2005, GE Security Inc. Introduction This is the GE Request-to-Exit Dual Technology Motion Sensor for models -W, -B, and -G.

More information

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

CM-RQE70A PIR REQUEST TO EXIT DETECTOR Door Activation Devices CM-RQE70A PIR REQUEST TO EXIT DETECTOR THIS PACKAGE INCLUDES (2) #6 x 3/4" Screws (2) 3/16" Wall Plugs (2) MOV's BP7175 1. GENERAL DESCRIPTION Camden CM-RQE70A Request-to-Exit Sensor

More information

CONVENTIONAL AUDIBLE VISUAL

CONVENTIONAL AUDIBLE VISUAL Fast Installation, Safe Evacuation CONVENTIONAL AUDIBLE VISUAL www.kac.co.uk Setting the Standard with ENscape EN54-23 and how it affects you EN54-23 is a new European standard for Visual Alarm Devices

More information

PSN-1000 & PSN 1000(E) Installation Manual

PSN-1000 & PSN 1000(E) Installation Manual PSN-1000 & PSN 1000(E) Installation Manual Potter Electric Signal Company, LLC St. Louis, MO Customer Service: (866) 240-1870 Technical Support: (866) 956-1211 Fax: (314) 595-6999 www.pottersignal.com

More information

Doc. No Part No Rev. U * T*

Doc. No Part No Rev. U * T* Doc. No. 430545 Part No. 579-357 Rev. U *0579357T* Blank Page- Back of Front Cover Copyrights and Trademarks 2005-2018 Johnson Controls. All rights reserved. Specifications and other information shown

More information

NEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK.

NEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK. VI64 Version:1.1 Issued 06/12/2007 INTRODUCTION Ventcroft s external sounder/strobes offer an unsurpassed range of models which provide for virtually any installation need. Most models feature a robust

More information

Installation Instructions

Installation Instructions Minn-XE Manuel issue no //0 7:9 am Page Installation Instructions Flashguard The Installer s Choice Minn-X Internal Alarm Sounder Minn-XE Internal Alarm Sounder with strobe Minn-XW External Alarm Sounder

More information

The EN54 Part 2 & 4 Fire System

The EN54 Part 2 & 4 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

Fire Signalling. Signalling Solutions

Fire Signalling. Signalling Solutions Fire Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place.

More information

Bulb Overview DESCRIPTION PART NO. TOTAL VOLTAGE FOR USE WITH: LENGTH(mm) Free-standing Beacons Accessories. Optical Signal Devices

Bulb Overview DESCRIPTION PART NO. TOTAL VOLTAGE FOR USE WITH: LENGTH(mm) Free-standing Beacons Accessories. Optical Signal Devices Bulb Overview PART NO. DESCRIPTION TOTAL LENGTH(mm) VOLTAGE FOR USE WITH: 955 840 34 Bulb BA15d 5 W 42 12 V 200 203 209 641 800 840 845 955 840 35 Bulb BA15d 5 W 42 24 V 200 203 209 641 800 840 845 955

More information