1 Model SS00C31 SmartSystem Load Management System LOAD MANAGER WITH ELECTRONIC SIREN/LIGHT CONTROL SYSTEM AND DIRECTIONAL LIGHT (with Slide Switch Control Head) OPERATION AND CONFIGURATION INSTRUCTIONS

2 LIMITED WARRANTY The Signal Division, Federal Signal Corporation (Federal), warrants each new product to be free from defects in material and workmanship, under normal use and service, for a period of two years on parts replacement and one year on labor from the date of delivery to the first user-purchaser. During this warranty period, the obligation of Federal is limited to repairing or replacing, as Federal may elect, any part or parts of such product which after examination by Federal discloses to be defective in material and/or workmanship. Federal will provide warranty for any unit which is delivered, transported prepaid, to the Federal factory or designated authorized warranty service center for examination and such examination reveals a defect in material and/or workmanship. This warranty does not cover travel expenses, the cost of specialized equipment for gaining access to the product, or labor charges for removal and re-installation of the product. Lamps, flash tubes, or batteries are not covered under warranty. This warranty does not extend to any unit which has been subjected to abuse, misuse, improper installation or which has been inadequately maintained, nor to units which have problems relating to service or modification at any facility other than the Federal factory or authorized warranty service centers. THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL FEDERAL BE LIABLE FOR ANY LOSS OF PROFITS OR ANY INDIRECT OR CONSEQUENTIAL DAMAGES ARISING OUT OF ANY SUCH DEFECT IN MATERIAL OR WORKMANSHIP.

3 OPERATION LRC O WARN SmartSystem-LMS FAST LOPWR PA/ STBY RAD WAIL YELP PRTY MAN A/H HI IDL A B C D E 290A Although it is extremely versatile, the SmartSystem-LMS (Model SS00C31) is operational right out of the box. It comes preconfigured according to the chart to the right. All operation instructions on this page will be in reference to the default configuration. Many of these functions, as well as some not listed, can be changed to meet the user s specific needs. Make sure to take the time to read through this manual to understand the full versatility of this product. All warnings and cautions that appear in the SS00C31 hardware installation and maintenance manual also apply to information given in this manual. Make sure you are aware of these warnings and cautions before you begin using this manual and reconfiguring the SS00C31 system. DEFAULT CONFIGURATION Load Manager Voltage Threshold V, 11.8V, and 12.8V Low Voltage Alarm - Enabled. Load Shedding Sequence - Relay E, D, C, B, A, 1, and 2. Slide Switch Position 1 - Activates relay 1 and Warn-1 on directional light. Slide Switch Position 2 - Activates relay 1 & 2, Warn 2 on directional light, and the Horn Ring Transfer Relay. Slide Switch Position 3 - Activates relay 1, 2, & 3, Warn 3 on directional light, the Horn Ring Transfer Relay, and enables the Siren. Auxiliary relay keys A-E activate the corresponding relays and are all Push On/Push Off type functions. STBY - Turns off sirens. RAD- Turns on Radio Rebroadcast. WAIL - Wail tone will activate only when the siren is enabled. In the default configuration, only mode 3 enables the siren. YELP - Yelp tone will activate only when the siren is enabled. PRTY - Priority tone will activate only when the siren is enabled. -1- MAN - Will produce peak & hold tone when no other sirens are active. If wail or yelp are active, the tone will change to priority for 8-seconds then revert back to the previous tone. Horn Ring will do the same if it is transferred to the siren. A/H - Will produce Air Horn tone any time it is pressed. LRC O - Directional light Arrow Step through (Left, Right, Center Out, Off). WARN - Directional light Warn Step through (Warn 1, 2, 3, 4 & Off). FAST - Directional light Arrows and Warn - fast speed override. LO PWR - Directional light Arrows - Low Power Pattern override. COMMON MIC. Control - enabled. HI IDLE Control - disabled.

4 SS00C31 Features Combined load management/ electronic siren and light control. Programmable load shedding at the point of installation. High Idle control capability. Two selectable sets of voltage thresholds for load manager. Audible indication and flashing LED for low battery alarm. Sirens can be configured to operate independent of switches. Program mode can be disabled to prevent unauthorized reprogramming. Each slide switch position can be configured to operate any combination of all eight relays plus, Horn Ring Transfer, Siren Enable, and any of the four warn patterns. Each Aux Relay can be configured as Push On/Push Off, Momentary, Eight Second Timeout, or Security Timeout. Any key on the siren row, except STBY, can be permanently disabled or enabled. Automatic High Idle output or manual control to enable high idle activator or solenoid. You can now select any keys, except MAN & A/H and the directional light keys to turn on automatically when the system is powered up. Your Horn Ring transfer tone can be YELP or PRIORITY. You can select Peak & Hold or Air Horn to activate with the horn ring. Relays sequence on and off to minimize power surges. Directional light Controller can operate SIX or EIGHT lamp directional light models. 34 different directional light Patterns Available. Programmable Function Indicator Sound notifies you if you have any functions active. CONFIGURATION WARNING Property damage, serious injury, or death to you or others may result if the SS00C31 is improperly configured. Configuration, if required, is to be performed at the time of installation. It is NOT intended for operators to customize the SS00C31 s operation for their individual preferences. It is the USER s responsibility to determine compatibility, suitability, and ensure proper configuration of the SS00C31. The person responsible for configuration MUST be familiar with local codes and procedures for safe emergency vehicle siren and light operation. Before proceeding, read and understand the Safety Message to Operators on page 5. Park - Siren Deactivator deactivates siren when vehicle is put in PARK. PA and Common Microphone control. The SS00C31 system is an extremely versatile system. Because of this versatility, it is very important to know how you want the system to function before you begin configuration. Therefore, be sure to read the directions before you begin configuration so that you may understand the capabilities of the SS00C31 system. To help in determining how your system will function, a worksheet outlining all the capabilities of the system is included at the back of this manual. Use this worksheet to determine exactly how your system should function, then begin the reconfiguring process. You will find that filling out the worksheet will help greatly reduce the time needed to configure your system to meet your requirements. Once you have determined how your system should operate, use this manual to guide you through the configuration process. On page 3 is an overview of the different levels of configuration. Similar functions are grouped together. Notice that level two is broken down into specific functional areas separated by arrows. These arrows represent a change into a deeper layer of level These deeper layers are only accessible from the previous layer. There is only one way into each layer and only one way out. Example: If you want to change the functionality of Slide Switch position 3, you must follow the flow of the arrows. 1. Select Level 2 from the MAIN MENU. 2. Select Slide Switches to drop into the Slide switch layer. 3. Select Slide Switch position 3 to drop into the Slide Functions layer. 4. Make your changes for Slide Switch 3 in the Slide Functions layer. *We have just completed one way in. We must now come out the same way by use of the key. 5. Press. This will bring you back up to Slide Switches. 6. Press again to bring yourself back up to Level Press again to bring yourself back up to the MAIN MENU. This is the extreme case as you will notice not all levels have sub-layers. Be aware that if we also wanted to reconfigure Slide Switch 2, we could have selected Slide Switch 2 in step 6 above without going all the way back to the MAIN MENU. This will reduce the number of key hits needed to configure your system.

5 CONFIGURATION TREE LEVEL 1 Keyboard Sirens Independent. Default Configuration. Configuration Disable. Directional Light 6 or 8 Lamp. Function Indicator Sound. SLIDE SWITCHES Select slide switch to reconfigure. LEVEL 2 Keys / Switches Slide Switches Aux Relay Keys Siren Disables AUX RELAY KEYS Select Aux Relay Key to reconfigure. SIREN DISABLE Select which sirens should be disabled/enabled. LEVEL 3 Power Up Select which keys should automatically activate when first powered up. LEVEL 4 Horn Ring Select Horn Ring Transfer Function Select transfer tone: Yelp. Priority. Select No Siren Active tone: Air Horn. Peak & Hold. Select 8-second HRTR Timer enabled. Timer disabled. LEVEL 5 Load Management Select Voltage Threshold Set for Load Manager: Enable Lower Voltage Threshold. Enable Higher Voltage Threshold. Select Load Shed sequence: Enable Load Shed. Select Shed sequence. Set Voltage Threshold: High Idle off threshold. Load Shed threshold. Low battery voltage alarm threshold. High Idle control: High Idle control enabled. High Idle control disabled. Low Battery Voltage Alarm Low voltage alarm enabled. Low voltage alarm disabled. SLIDE FUNCTIONS Select combinations of the following for each switch position: Primary Relays. Auxiliary Relays. Key 11. Horn Ring Transfer. Siren Enable. Directional Light Warn Pattern. AUX RELAY FUNCTIONS Select one of the following for each Aux Relay: Push-on / Push-off. Momentary. 8-Second Timer. Security Timer. -3-

6 -4-

7 SECTION IV OPERATION SAFETY MESSAGE TO OPERATORS OF FEDERAL SIGNAL ELECTRONIC SIRENS AND LIGHT/SOUND SYSTEMS WARNING The lives of people depend on your safe operation of Federal products. It is important to read and follow all instructions shipped with the products. In addition, listed below are some other important safety instructions and precautions you should follow: Qualifications To properly use an electronic siren and speaker(s): you must have a good understanding of general vehicle operation, a high proficiency in the use of safety warning equipment, and thorough knowledge of state and federal UNIFORM TRAFFIC CODES. Sound Hazards Your hearing and the hearing of others, in or close to your emergency vehicle, could be damaged by loud sounds. This can occur from short exposures to very loud sounds, or from longer exposures to moderately loud sounds. For hearing conservation guidance, refer to federal, state, or local recommendations. OSHA Standard offers guidance on Permissible Noise Exposure. All effective sirens and horns produce loud sounds (1 db) that may cause permanent hearing loss. Always minimize your exposure to siren sound, roll up your windows and wear hearing protection. Do not sound the siren indoors or in enclosed areas where you and others will be exposed to the sound. Only use the siren for emergency response situations. Sound Limitations Before using the vehicle, check to see if the siren speakers are concealed from view. If the siren speaker is not in clear view on the front of the vehicle, use extra caution when operating the vehicle. A concealed siren speaker installation is less effective at warning others. Maximum sound output will be severely reduced if any objects are in front of the speaker. If your installation has obstructions in front of the speaker, drive even more cautiously. Frequently inspect the speaker to ensure that it is clear of any obstruction, such as mud or snow, which will reduce maximum sound output. Signaling Limitations Be aware that the use of your visual and audible signaling devices does not give you the right to force your way through traffic. Your emergency lights, siren, and actions are REQUESTING the right-of-way. Although your warning system is operating properly, it may not alert everyone. People may not hear, see, or heed your warning signal. You must recognize this fact and continue driving cautiously. Situations may occur which obstruct your warning signal when natural or man-made objects are between your vehicle and others. This can also occur when you raise your hood or trunk lid. If these situations occur, be especially careful. Driving Limitations At the start of your shift, you should ensure that the light/sound system is securely attached to the vehicle and operating properly. If the unique combination of emergency vehicle equipment installed in your vehicle has resulted in the siren controls being installed in a position that does not allow you to operate them by touch only, OPERATE CONTROLS ONLY WHILE YOUR VEHICLE IS STOPPED. If driving conditions require your full attention, you should avoid operating the siren controls the vehicle is in motion. Continuing Education File these instructions in a safe place and refer to them periodically. Give a copy of these instructions to new recruits and trainees. Failure to follow these safety precautions may result in property damage, serious injury, or death to you, to passengers, or to others. -5-

8 SmartSystem-LMS MAIN MENU LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 LEVEL 5 Entering Configuration Mode To enter configuration mode, simply execute the following steps: 1. Power up the system and wait for startup to finish. 2. Unplug control head. 3. Press and continue to hold. 4. Plug control head back in continuing to hold. 5. Release the key. The MAIN MENU will come up on the keyboard as soon as you enter configuration mode. Keys 10, 11, 12, 13, and 14 buttons will be solidly illuminated. At this point you have six choices: ENTER LEVEL 1 ENTER LEVEL 2 ENTER LEVEL 3 ENTER LEVEL 4 ENTER LEVEL 5 Pressing (Key 9) will save the present configuration to permanent memory, end the configuration session, and put the system into operation mode. LEVEL 1 Pressing LEVEL 1 (Key 10) will enter LEVEL 1 (Keyboard). If LEVEL 1 is selected, go to page 7, LEVEL 1 (Keyboard). LEVEL 2 Pressing LEVEL 2 (Key 11) will enter LEVEL 2 (Keys). If LEVEL 2 is selected, go to page 8, LEVEL 2 (Keys). LEVEL 3 Pressing LEVEL 3 (Key 12) will enter LEVEL 3 (Power Up). If LEVEL 3 is selected, go to page 14, LEVEL 3 (Power Up). LEVEL 4 Pressing LEVEL 4 (Key 13) will enter LEVEL 4 (Horn Ring). If LEVEL 4 is selected, go to page 15, LEVEL 4 (Horn Ring). LEVEL 5 290A Pressing LEVEL 5 (Key 14) will enter LEVEL 5 (Load Management). If LEVEL 5 is selected, go to page 16, LEVEL 5 (Load Management). -6-

9 LEVEL 1 (Keyboard) SmartSystem-LMS Function Indicator Sound Directional Light Sirens Independent Default Configuration Configuration Mode Disable LEVEL 1 (Keyboard) is where options are chosen that affect the entire keyboard. These options are whether you want the siren keys to act independently of the rest of the keyboard, whether you want the default, factory settings, configuration, or whether you want configuration mode disabled after this configuration session. Save displayed LEVEL 1 settings and return to MAIN MENU, page 6. Function Indicator Sound If key 12 is on, the control head will beep about every ten seconds if a function, besides the sirens, is active. Directional Light 6 If key 13 is on, then the directional light will operate in the 6-Lamp mode. If key 13 is off, then the directional light will operate in the 8-Lamp mode. Sirens Independent If key 14 is on, then the sirens will act independently of the slide switches. That is, in operation mode, if a siren key is pressed, the siren tone will be produced immediately. If key 14 is off, the sirens, in operation mode, will require that one of the slide switches be activated before the siren tone will be produced. Which slide switch will turn on the sirens is optional and will be discussed in Level 2 - Slide Switch - Function, on page 10. Default Configuration If key 15 is on, then the keyboard is configured according to the factory 290A default settings (see OPERATION, page 1). If key 15 is off, then the present configuration does not match the factory default settings. To put the system back in factory default configuration, turn key 15 on. Remember, this will erase all previous configuration information. Configuration Mode Disable If key 16 is turned on, you will not be able to re-enter configuration mode once you exit this session. To re-enter configuration mode at a later date, the Push To Talk button on the microphone for the siren system must be on the key is pressed to enter configuration mode as referred to on page 6. The Push to Talk button must be held until you re-enter level 1 and turn off key 16. Once this is accomplished you can release the Push to Talk button on the microphone and proceed with reconfiguration as normal. -7-

10 SmartSystem-LMS LEVEL 2 (Keys) Slide Switches Keys Siren Disable Level 2 (Keys) is used to specifically configure each key or switch. Level 2 allows you to change how each Slide Switch, Auxiliary Relay Key, Siren Key, and Key 11/Pursuit Switch functions. Save LEVEL 2 settings and return to MAIN MENU, page 6. Slide Switches Pressing Slide Switches (Key 13) will enter LEVEL 2 - Slide Switches. If Slide Switches is selected, go to page 9, Level 2 - Slide Switches. Aux Relay Keys Pressing Aux Relay Keys (Key 14) will enter LEVEL 2 - Aux Relay Keys. If Aux Relay Keys is selected, go to page 11, Level 2 - Aux Relay Keys. Siren Disable 290A Pressing Siren Disable (Key 15) will enter LEVEL 2 - Siren Disable. If Siren Disable is selected, go to page 13, Level 2 - Siren Disable. -8-

11 LEVEL 2 - Slide Switches SmartSystem-LMS Slide 1 Slide 2 Slide 3 Level 2 Slide Switches determines which Slide Switch position to reconfigure. Save LEVEL 2 - Slide Switch settings and return to LEVEL 2 (Keys), page 8. Slide 1 Press Slide 1 to reconfigure how Slide Switch, position 1, functions. If Slide 1 is selected, go to Level 2 - Slide Switch - Function, page 10, to reconfigure Slide Switch 1. Slide 2 Press Slide 2 to reconfigure how Slide Switch, position 2, functions. If Slide 2 is selected, go to Level 2 - Slide Switch - Function, page 10, to reconfigure Slide Switch 2. Slide 3 290A Press Slide 3 to reconfigure how Slide Switch, position 3, functions. If Slide 3 is selected, go to Level 2 - Slide Switch - Function, page 10, to reconfigure Slide Switch

12 LEVEL 2 - Slide Switch - Function Directional Light Warn - 1 Directional Light Warn - 2 SmartSystem-LMS Directional Light Warn - 3 Directional Light Warn - 4 Relay 1 Relay 2 Relay 3 Horn Ring Transfer Enable Siren Enable A B C D E Level 2 - Slide Switch - Function, is where the slide switch position just selected is configured. All relays can be configured to come on with the switch as well as Horn Ring Transfer and Siren Enable. Pressing the key will save what is displayed and you will return to Level 2 - Slide Switches, page 9. Aux Relays Any combination of Auxiliary relays can be configured to activate with the Slide Switch position being reconfigured. Simply turn on (or turn off) the desired Aux Relay Keys as labeled above. Relays 1, 2, & 3 Any combination of Relays 1, 2, and/ or 3 can be configured to activate with the Slide Switch position being reconfigured. Simply turn on (or turn off) the desired Relay Keys as labeled above. Horn Ring Transfer The Horn Ring Transfer can be configured to automatically turn on with the Slide Switches. To do so, turn on Key 15, Horn Ring Transfer. Siren Enable 290A If sirens are configured to be dependent on the slide switch, this is where you enable the siren. If you want the siren to be enabled for the slide switch position you are configuring, just turn on the Siren Enable key, key 16. Directional Light Warn 1-4 If a directional light Warning Pattern is desired to activate with the slide switch being programmed, just turn on the appropriate key for the warning pattern you need. If no warning pattern is needed, turn off all directional light Warn keys. -10-

13 LEVEL 2 - Aux Relay Keys SmartSystem-LMS A B C D E Level 2 - Aux Relay Keys determines which Aux Relay Key to reconfigure. Save LEVEL 2 - Aux Relay Key settings and return to LEVEL 2 (Keys), page 8. Aux Relay A Press Aux Relay A to reconfigure how Aux Relay A, key 4, functions. If Aux Relay A is selected, go to Level 2 - Aux Relays - Function, page 12, to reconfigure Aux Relay A. Aux Relay B Press Aux Relay B to reconfigure how Aux Relay B, key 5, functions. If Aux Relay B is selected, go to Level 2 - Aux Relays - Function, page 12, to reconfigure Aux Relay B. Aux Relay C Press Aux Relay C to reconfigure how Aux Relay C, key 6, functions. If Aux Relay C is selected, go to Level 2 - Aux Relays - Function, page 12, to reconfigure Aux Relay C. Aux Relay D Press Aux Relay D to reconfigure how Aux Relay D, key 7, functions. If Aux Relay D is selected, go to Level 2 - Aux Relays - Function, page 12, to reconfigure Aux Relay D. Aux Relay E 290A Press Aux Relay E to reconfigure how Aux Relay E, key 8, functions. If Aux Relay E is selected, go to Level 2 - Aux Relays - Function, page 12, to reconfigure Aux Relay E. -11-

14 LEVEL 2 - Aux Relays - Function SmartSystem-LMS Push-on/ Push-off Momentary 8-Second Timer Security Timer Level 2 - Auxiliary Keys - Function is where you decide how the Auxiliary Relays are going to function. Save LEVEL 2 - Aux Relays - Function key settings and return to LEVEL 2 - Aux Relays, page 11. Push On / Push Off Select Push On / Push Off (Key 12) if you want the Aux Relay you are configuring to act as a standard Push On / Push Off switch. Momentary Select Momentary (Key 13) if you want the Aux Relay you are configuring to act as a Momentary Switch. 8-Second Timer Select 8-Second Timer (Key 14) if you want the Aux Relay you are configuring to automatically turn itself off after 8 seconds. Security Timer 290A Select Security Timer (Key 15) if you want the Aux Relay you are configuring to require security operation to turn on and automatically turn itself off after 8 seconds. When operating, the security timer requires two key hits to operate. When the security key is first hit, it will not turn on. It will not turn on until the STBY key is hit immediately following the security key hit. This gives you your two key press security timer. -12-

15 LEVEL 2 - Siren Enable/Disable SmartSystem-LMS Radio Wail Yelp Hi-Lo Manual Air Horn Priority Level 2 - Siren Enable/Disable is where you can enable or disable siren tones and radio rebroadcast. This is also where you choose between the High Low tone or the Priority tone, or neither, for key 14. Save LEVEL 2 - Siren Enable/Disable settings and return to LEVEL 2 (Keys), page 8. RAD WAIL YELP MAN A/H Turn on the key to enable one of the above tones/key. Turn off the key to disable one of the above tones/key. 290A H/L or PRIORITY Key 14 can be configured to activate either the High Low tone or the Priority tone, or neither. Turn on key 14 if you want High Low to activate on key 14. Turn on key 6 if you want PRIOR- ITY to activate on key 14. Turn both off if you want neither to be activated by key

16 LEVEL 3 (Power Up) SmartSystem-LMS Level 3 - Power Up is where you decide what keys should turn on automatically when the system is turned on. Save LEVEL 3 - Power Up settings and return to MAIN MENU page 6. Turn on the keys you want to turn on automatically when the system is powered up. Remember, only one siren or the RAD key can be selected at a time. If no sirens or RAD is selected, the system will power up in stand-by. Note 290A If the sirens are configured to be independent of the slide switch, make sure no sirens are selected on power up. -14-

17 LEVEL 4 (Horn Ring) SmartSystem-LMS 8-Second Timeout Horn Ring Transfer Tone Yelp Priority No Siren Active Tone Peak & Hold Air Horn Level 4 - Horn Ring is where you decide how you want the horn ring to function when it is transferred to the siren. Save LEVEL 4 - Horn Ring settings and return to MAIN MENU page 6. 8-Second Timeout Activate key 12 if you want the Horn Ring Transfer tone to revert back to the original tone after 8 seconds. Horn Ring Transfer Tone The Horn Ring transfer tone is the tone that will be produced when you have a less urgent tone (such as wail) already active, the horn is transferred, and you press the horn. If the tone cannot transfer to a more urgent tone, the Air Horn will momentarily sound. 290A Activate key 13 if you want YELP to be this tone. Activate key 14 if you want PRIORITY. No Siren Active Tone The no siren active tone is the tone that will be produced when you have no sirens active, the horn is transferred, and you press the horn. Activate key 15 if you want this tone to be Peak & Hold. Activate key 16 if you want this tone to be Air Horn. -15-

18 LEVEL 5 Load Management SmartSystem-LMS Load Shed Sequence Voltage Threshold Higher Voltage Settings Enable High Idle Control Enable Low Voltage Alarm Enable Lower Voltage Settings Enable Common Microphone Control Enable Level 5 - Load Management is where you decide which relays should shed (turn off), the shedding sequence, what voltage should start shedding, enabling of automatic high idle control, and enabling of the low voltage alarm. Save LEVEL 5 - Load Management settings and return to MAIN MENU page 6. Load Shed Sequence Press key 10 Load Shed Sequence to reconfigure how the load manager manages relays. It can be configured so that relay outputs are not managed. Relays then opreate in a normal on/off control mode. To reconfigure the load manager when Load Shed Sequence is selected, go to Level 5 - Load Shed Sequence, page 17. Voltage Threshold Press key 11 Voltage Threshold to reconfigure the load manager voltage thresholds. Three voltage thresholds are programmable as follows: High Idle Control Voltage Threshold. Load Shedding Voltage Threshold. Low Battery Voltage Alarm Voltage Threshold. To reconfigure the voltage thresholds when Voltage Threshold is selected, go to Level 5 - Voltage Threshold, page 18. High Idle Control Enable Press key 15 High Idle Control Enable to enable/disable the High Idle relay output 2A max.). The High Idle output operates in conjunction with the PARK input. If the vehicle is shifted out of PARK, the High Idle relay will NOT turn on. The key 15 LED is on when High Idle control is enabled and off when High Idle control is disabled. The High Idle control and Common Microphone control are mutually exclusive. Common Microphone Control Enable Press key 7 "Common Microphone Control Enable" to enable/disable the common microphone relay output 2A max.). A common microphone module eliminates the need for two microphones. The key 7 LED is on when Common Microphone control is enabled and -16- off when Common Microphone control is disabled. The Common Microphone control and High Idle control are mutually exclusive. Low Voltage Alarm Enable 290A Press key 16 Low Voltage Alarm Enable to enable/disable the Low Volatge Alarm. The Low Voltage Alarm turns on if the unit senses that the battery voltage is below the low voltage threshold for 30 seconds or more. The key 16 LED is on when the Low Voltage Alarm is enabled and off when the Low Voltage Alarm is disabled. Higher Voltage Settings Enable To enable the higher load magager threshold voltage settings (13.8V, 12.8V, and 11.8V), press key 12. This setting in conjunction with High Idle control enable is intended for fire application use. Lower Voltage Settings Enable To enable the lower load manager threshold voltage settings (12.8V, 11.8V, and 11.0V), press key 4.

19 LEVEL 5 Load Shed Sequence SmartSystem-LMS Reset (No Shed) A B C D E Level 5 - Load Shed Sequence is where you decide which relays should shed (turn off) and the shedding sequence. Save LEVEL 5 - Load Shed Sequence settings and return to Level 5, Load Management, page 16. Load Shed Sequence To reconfigure the Load Shed Sequence, press the Aux Relay keys one at a time in the desired shedding sequence order. The order in which the keys are pressed is the shedding sequence. Press only the keys which correspond to the relays which need to be managed. The load manager will NOT shed relays which are NOT in the shedding sequence. Eight relays, Aux Relays 1-3 and Aux Relays A-E, can be programmed as load managed outputs. The load manager will shed the programmed relays in the shedding order when the vehicle is shifted into PARK and the battery voltage drops below the reference voltage (shedding threshold voltage) for 30 seconds or more. If the High Idle Control is enabled, High Idle will activate to remedy the low battery condition before load shedding begins. Previously shed loads are NOT restored if the battery voltage rises above the reference voltage. Previously shed loads are ONLY restored at 0.5 second intervals in reverse sequence when the vehicle is shifted out of PARK. 290A Previously shed loads can be restored manually by pushing the associated keys. Press key 16 Reset (No Shed) to reset the load manager. After this key is pressed and saved, no load shedding will occur. IMPORTANT Determining which loads are managed is a critical decision. It is suggested that only non-critical relays are managed. It is the user's responsibility to determine which loads are managed. -17-

20 LEVEL 5 Voltage Threshold SmartSystem-LMS Enable lower Voltage Threshold Programming Enable Higher Voltage Threshold Programming Low Voltage Alarm Threshold Load Shed Threshold High Idle Off Threshold Level 5 - Voltage Threshold is where you configure three voltage thresholds used by the load manager. Save LEVEL 5 - Voltage Threshold settings and return to Level 5, Load Management, page 16. CAUTION The two sets of default voltage thresholds are set at: 11.8 V, 12.8 V, and 13.8 V; and 11.0V, 11.8V, and 12.8V. DO NOT change the voltages if not necessary. If the thresholds are changed, the initial defaults are lost and the new settings replace the default values. The system does NOT reset to the factory voltage threshold defaults even when the Default Configuration is selected in Level 1 (see page 7). Voltage Thresholds Higher Voltage The higher voltage threshold programming can be performed only when key 15 is pressed and the key 15 LED turns on. Press key 15 to enable higher voltage threshold programming. To perform the voltage threshold programming, obtain an adjustable DC power supply (2A min.) and a voltmeter. Use the power supply to power the system. Leave all switches off and adjust the DC power supply output to 14 volts. Enter the programming mode, LEVEL 5 - Voltage Threshold. Press key 15 to enable voltage threshold programming. Adjust the DC power supply output to the High Idle off voltage (default: 13.8V) and press key 6. Adjust the DC power supply output to the Load Shed Threshold voltage (default: 12.8V) and press key 5. Adjust the DC power supply output to the Low Voltage Alarm Threshold voltage (default: 11.8V) and press key 4. The adjustable voltage threshold range is volts. The flow chart on page illustrates how the load manager works in conjunction with voltage thresholds. Press key 9 to save after all voltage thresholds are programmed and return to Level 5 - Load Management, page 16 Lower Voltage The lower voltage threshold programming can be performed only when key 12 is pressed and the key 12 LED turns on. Press key 12 to enable lower voltage threshold programming. To perform the voltage threshold programming, obtain an adjustable DC power supply (2A min.) and a voltmeter. Use the power supply to power the system. Leave all switches off and adjust the DC power supply output to 14 volts. Enter the programming mode, LEVEL 5 - Voltage Threshold. Press key to enable voltage threshold programming. Adjust the DC power supply output to the High Idle off voltage (default: 12.8V) and press key 6. Adjust the DC power supply output to the Load Shed Threshold voltage (default: 11.8V) and press key 5. Adjust the DC power supply output to the Low Voltage Alarm Threshold voltage (default: 11.0V) and press key 4. The adjustable voltage threshold range is volts. The flow chart on page illustrates how the load manager works in conjunction with voltage thresholds. Press key 9 to save after all voltage thresholds are programmed and return to Level 5 - Load Management, page 16 IMPORTANT 290A Voltage thresholds dramatically affect the performance of the load manager. Changing voltage thresholds from default settings is the user s responsibility. Voltage measurement during programming voltage thresholds is critical. Voltage MUST be measured at pin 6 (red wire) and pin 4 (black wire) of the unit s power cable (see figure 3-6 in the supplied Hardware Installation and Maintenance Instructions). Improper load manager operation will result if voltage measurements, or settings, are incorrect. It is strongly recommended that only trained, or experienced technicians, perform the voltage threshold settings.

21 Load Management Flow Chart Subroutine for Load Management EXIT C1 C2 C3 Vehicle in PARK? Volts > 12.8V for 30 sec.? * Yes Yes * Volts < 12.8V for 30 sec.? Is Low Voltage Alarm On? Yes Yes Was High Idle turned on? Turn Low Voltage Alarm Off No No Yes Shed load according to the programmed sequence No * Volts > 13.8V for 30 sec.? Yes Was Low voltage alarm on? No Is High Idle On? No Yes No Yes EXIT Turn High Idle Off No Turn High Idle on No Volts < 11.8V for 30 sec.? * Update status flags If loads were shed before, turn back on in reversed sequence Yes Turn Low voltage alarm on No RETURN from subroutine C1 C2 C3 * NOTE: 11.8V, 12.8V AND 13.8V CAN BE PROGRAMMED TO BE ANY VOLTAGE BETWEEN 11V - 15V (HIGHER THRESHOLD SHOWN) 290A

22 Worksheet Level 1 Sirens independent of slide switch Yes No Function Indicator Sound Yes No Directional light Type 6-Lamp 8-Lamp Level 2 - Keys/Switches Slide Switch (Circle any combination for each slide switch position.) Relays Auxiliary Relays Misc. SignalMaster Warn Pattern Position A B C D E HRTR SIREN Position A B C D E HRTR SIREN Position A B C D E HRTR SIREN Auxiliary Relays (Circle one of the following for each relay.) A Push-on/Push-off Momentary 8-second timeout Security timeout B Push-on/Push-off Momentary 8-second timeout Security timeout C Push-on/Push-off Momentary 8-second timeout Security timeout D Push-on/Push-off Momentary 8-second timeout Security timeout E Push-on/Push-off Momentary 8-second timeout Security timeout Siren Enable (Circle the tones/switches to be enabled.) RAD WAIL YELP H/L or PRIORITY MAN A/H Level 3 - Power-up (Circle which keys are to be activated upon power-up.) STBY RAD WAIL YELP H/L or PRIORITY RELAY A RELAY B RELAY C RELAY D RELAY E Level 4 - Horn Ring 8-Second Timeout Yes No Transfer Tone YELP PRIORITY No Siren Active Tone PEAK & HOLD Air Horn Level 5 - Load Management Load Shed Sequence (Determine relay shed sequence.) Relay 1 ( ) Relay 2 ( ) Relay 3 ( ) Relay A ( ) Relay B ( ) Relay C ( ) Relay D ( ) Relay E ( ) Voltage Threshold (Enter load management voltage thresholds.) Low Voltage Alarm Voltage ( ) Load Shed Threshold Voltage ( ) High Idle Off Voltage ( ) High Idle Enable Disable Common Microphone Enable Disable Low Voltage Alarm Enable Disable Higher Voltage Threshold Lower Voltage Threshold --

23 Relay/Device Assignments List below which controlled devices are connected to which relay. Relay 1 (-amperes max.) Relay 2 (-amperes max.) Relay 3 (40-amperes max.) Relay A (10-amperes max.) Relay B (10-amperes max.) Relay C (10-amperes max.) Relay D (10-amperes max.) Relay E (10-amperes max.) Is Horn Ring Transfer used? Yes No Is the Radio Rebroadcast Switch used? Yes No Is the High Idle Relay used? Yes No Additional Notes:

24 255352A REV. A 903 Printed in U.S.A.

Model SS2000SM Series ELECTRONIC SIREN/LIGHT CONTROL SYSTEM WITH SignalMaster DIRECTIONAL LIGHT (with Slide Switch Control Head)

Model SS2000SM Series ELECTRONIC SIREN/LIGHT CONTROL SYSTEM WITH SignalMaster DIRECTIONAL LIGHT (with Slide Switch Control Head) Model SS00SM Series ELECTRONIC SIREN/LIGHT CONTROL SYSTEM WITH SignalMaster DIRECTIONAL LIGHT (with Slide Switch Control Head) OPERATION AND CONFIGURATION INSTRUCTIONS LIMITED WARRANTY The Signal Division,

More information

Model SS2000SS Series ELECTRONIC SIREN AND LIGHT CONTROL SYSTEM (with Slide Switch Control Head)

Model SS2000SS Series ELECTRONIC SIREN AND LIGHT CONTROL SYSTEM (with Slide Switch Control Head) Model SS2000SS Series ELECTRONIC SIREN AND LIGHT CONTROL SYSTEM (with Slide Switch Control Head) OPERATION AND CONFIGURATION INSTRUCTIONS LIMITED WARRANTY The Signal Division, Federal Signal Corporation

More information

SS2000 Software Configuration Manual

SS2000 Software Configuration Manual SS2000 Software Configuration Manual I SS2000 Configuration Guide Table of Contents Foreword 0 Part I Safety Message to Users of this Software 2 Part II Vehicle Operation 3 1 Installing the... SS2000 Configurator

More information

Table of Contents. Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4. Part III Safety Messages 13

Table of Contents. Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4. Part III Safety Messages 13 Manual I SS2000 TouchScreen Installation Guide Table of Contents Foreword 0 Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4 1 Installing the... SS2000 TouchScreen

More information

PREMIUM VISION WARNING SYSTEM (with Slide Switch Control Head)

PREMIUM VISION WARNING SYSTEM (with Slide Switch Control Head) Price $15.00 PREMIUM VISION WARNING SYSTEM (with Slide Switch Control Head) OPERATION AND CONFIGURATION INSTRUCTIONS SECTION I OPERATION SAFETY MESSAGE TO OPERATORS OF FEDERAL SIGNAL LIGHT/SOUND SYSTEMS

More information

I N S T A L L A T I O N Omega 90 Amplifier

I N S T A L L A T I O N Omega 90 Amplifier 22-U90-00 ECO# 104-06-MAN I N S T A L L A T I O N Omega 90 Amplifier FS UNITROL 1108 RAYMOND WAY ANAHEIM, CA 92801 (714) 871-6 (800) 854-75 FAX (714) 871-418 SECTION TITLE PAGE I General Information 1

More information

PRICE $4.00 MODEL PA400SS ELECTRONIC SIREN INSTALLATION AND OPERATION INSTRUCTIONS

PRICE $4.00 MODEL PA400SS ELECTRONIC SIREN INSTALLATION AND OPERATION INSTRUCTIONS PRICE $4.00 MODEL PA400SS ELECTRONIC SIREN INSTALLATION AND OPERATION INSTRUCTIONS LIMITED WARRANTY The Signal Division, Federal Signal Corporation (Federal), warrants each new product to be free from

More information

PRICE $4.00 MODEL PA4000 ELECTRONIC SIREN INSTALLATION, OPERATION, AND SERVICE INSTRUCTIONS

PRICE $4.00 MODEL PA4000 ELECTRONIC SIREN INSTALLATION, OPERATION, AND SERVICE INSTRUCTIONS PRICE $4.00 MODEL PA4000 ELECTRONIC SIREN INSTALLATION, OPERATION, AND SERVICE INSTRUCTIONS LIMITED WARRANTY The Signal Division, Federal Signal Corporation (Federal), warrants each new product to be free

More information

Model AS124 Siren Speaker and Mounting Kit Installation Instructions

Model AS124 Siren Speaker and Mounting Kit Installation Instructions Model AS124 Siren Speaker and 750501-07 Mounting Kit 25500127 A Rev. A0 0614 Printed in U.S.A. 2016 Federal Signal Corporation. All rights reserved. Contents Safety Messages to Installers of Siren Speakers...5

More information

INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS FOR Q-SIREN MODELS Q2B-012P, Q2B-012NN, AND Q-MT

INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS FOR Q-SIREN MODELS Q2B-012P, Q2B-012NN, AND Q-MT 256A768K REV. K 506 Printed in U.S.A. INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS FOR Q-SIREN MODELS Q2B-012P, Q2B-012NN, AND Q-MT SAFETY MESSAGE TO INSTALLERS The lives of people depend on your

More information

Model SS2000 ELECTRONIC SIREN AND LIGHT CONTROL SYSTEM

Model SS2000 ELECTRONIC SIREN AND LIGHT CONTROL SYSTEM Price $4.00 Model SS2000 ELECTRONIC SIREN AND LIGHT CONTROL SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS LIMITED WARRANTY The Signal Division, Federal Signal Corporation (Federal), warrants each new

More information

Safety Message to Installers of Siren Speakers

Safety Message to Installers of Siren Speakers ESB-IMP08R Mounting Bracket Kit for the ES100 Speaker in the 2006 and Newer Chevy Impala 2562598A REV. A 411 Safety Message to Installers of Siren Speakers People s lives depend on your proper installation

More information

Model PA300 Series ELECTRONIC SIREN MODELS , , ,

Model PA300 Series ELECTRONIC SIREN MODELS , , , Price $4.00 Model PA300 Series ELECTRONIC SIREN MODELS 690000, 690001, 690002, 690004 INSTALLATION AND OPERATING INSTRUCTIONS LIMITED WARRANTY The Signal Division, Federal Signal Corporation (Federal),

More information

Carson Manufacturing Co., Inc North Rural Street Indianapolis, IN Phone: (888) Fax: (317)

Carson Manufacturing Co., Inc North Rural Street Indianapolis, IN Phone: (888) Fax: (317) Carson Manufacturing Co., Inc. 5451 North Rural Street Indianapolis, IN 46220 Phone: (888) 577-6877 Fax: (317) 254-2667 www.carsonsirens.com SC-1012-20 SIREN AMPLIFIER W/ LIGHT CONTROL SC-1012 LT1 LT2

More information

Safety Message to Installers of Federal Signal Siren Speakers

Safety Message to Installers of Federal Signal Siren Speakers Model RB-CRG11 Mounting Bracket Kit for the Rumbler Speaker in the 2011 and Newer Dodge Charger 2562629B REV. B 312 Safety Message to Installers of Federal Signal Siren Speakers People s lives depend on

More information

2007 POLICEP PACKAGES FORD POLICE INTERCEPTOR PREPARATION PACKAGES 65U READY

2007 POLICEP PACKAGES FORD POLICE INTERCEPTOR PREPARATION PACKAGES 65U READY 2007 POLICEP PACKAGES FORD POLICE INTERCEPTOR PREPARATION PACKAGES 65U READY FOR THE ROAD TABLE OF CONTENTS Option Content 65A and 65N Package... 3 Option Content 68P and 65W... 4 Option Content 65U Ready

More information

Be sure the siren amplifier and speaker(s) in your installation have compatible wattage ratings.

Be sure the siren amplifier and speaker(s) in your installation have compatible wattage ratings. Model RB-CAP11 Mounting Kit for the Rumbler Speaker in a 2011 and Newer Chevy Caprice 2562648A REV. A 1011 Safety Message to Installers of Siren Speakers People s lives depend on your proper installation

More information

Installation Instructions for Q-Siren Q2B-012PSD, Q2B-012NNSD, and Q-MT

Installation Instructions for Q-Siren Q2B-012PSD, Q2B-012NNSD, and Q-MT 256A768L Rev. L0 0817 Safety Message to Installers of Warning Equipment Installation Instructions for Q-Siren Q2B-012PSD, Q2B-012NNSD, and Q-MT The lives of people depend on your proper installation and

More information

Safety Message to Installers of Federal Signal Siren Speakers

Safety Message to Installers of Federal Signal Siren Speakers Mounting Instructions for the Rumbler 82831072 Low Frequency Speaker 2562414D REV. D 312 Safety Message to Installers of Federal Signal Siren Speakers People s lives depend on your proper installation

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 1340 Russell Cave Road Lexington, KY 40505 1-800-477-7766 www.galls.com SIREN MODEL GS-150 YELP ON MANUAL/ THUNDER STBY WAIL OFF RAD PA VOL GS - 150 INSTALLATION INSTRUCTIONS Page 2 LIMITED WARRANTY Galls

More information

385 SERIES REMOTE HANDHELD SIREN ETSA385HR

385 SERIES REMOTE HANDHELD SIREN ETSA385HR ! WARNING Sirens produce loud sounds that may damage hearing: - Roll up windows. - Wear hearing protection. - Use only for emergency response. - Avoid exposure to siren sound outside of vehicle. Please

More information

SA SIREN AMPLIFIER

SA SIREN AMPLIFIER Carson Manufacturing Co., Inc. 5451 North Rural Street Indianapolis, IN 46220 Phone: (888) 577-6877 Fax: (317) 254-2667 www.carsonsirens.com SA-365-10 SIREN AMPLIFIER Y E L P STANDBY SA-365 W AI L OUTPUT

More information

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance. WARNING: Warning devices are strictly! WARNING Sirens produce loud sounds that may damage hearing: - Roll up windows. - Wear hearing protection. - Use only for emergency response. - Avoid exposure to siren

More information

INSTALLATION AND INSTRUCTION MANUAL

INSTALLATION AND INSTRUCTION MANUAL INSTALLATION AND INSTRUCTION MANUAL SS650-013 013 SIREN LCS652-013 SIREN and Light Controller PLITSTR247 REV. F 12/9/13 NOTICE Due to continuous product improvements, we must reserve the right to change

More information

380 SERIES REMOTE SIREN ETSA380R

380 SERIES REMOTE SIREN ETSA380R ! WARNING Sirens produce loud sounds that may damage hearing: - Roll up windows. - Wear hearing protection. - Use only for emergency response. - Avoid exposure to siren sound outside of vehicle. Please

More information

Street Thunder ST280 SIREN AMPLIFIER & LIGHT CONTROLLER INSTALLATION AND OPERATING INSTRUCTIONS

Street Thunder ST280 SIREN AMPLIFIER & LIGHT CONTROLLER INSTALLATION AND OPERATING INSTRUCTIONS Street Thunder ST280 SIREN AMPLIFIER & LIGHT CONTROLLER INSTALLATION AND OPERATING INSTRUCTIONS 1340 Russell Cave Road / P.O. Box 54308 Lexington, KY 40505 Tel: (800) 477-7766 Fax: (800) 944-2557 www.galls.com

More information

Alarm Tone Generator Model AG17

Alarm Tone Generator Model AG17 Alarm Tone Generator Installation & Operation P005089 Rev. C 150930 9/30/2015 12:25 PM Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com Table of Contents Package Contents...

More information

ST240 SIREN Installation and Operating Instructions

ST240 SIREN Installation and Operating Instructions Street Thunder ST240 SIREN Installation and Operating Instructions NOTICE Due to continuous product improvements, we must reserve the right to change any specifications and information contained in this

More information

SA VOLT SIREN AMPLIFIER

SA VOLT SIREN AMPLIFIER Carson Manufacturing Co., Inc. 5451 North Rural Street Indianapolis, IN 46220 Phone: (888) 577-6877 Fax: (317) 254-2667 www.carsonsirens.com SA-400-10 28 VOLT SIREN AMPLIFIER RADIO MAN WAIL YELP PHASER

More information

Street Thunder ST240 SIREN AMPLIFIER INSTALLATION AND OPERATING INSTRUCTIONS

Street Thunder ST240 SIREN AMPLIFIER INSTALLATION AND OPERATING INSTRUCTIONS Street Thunder ST240 SIREN AMPLIFIER INSTALLATION AND OPERATING INSTRUCTIONS 1340 Russell Cave Road / P.O. Box 54308 Lexington, KY 40505 Tel: (800) 477-7766 Fax: (800) 944-2557 Website: www.galls.com REV.

More information

THE COMMISIONER TM 200 WATT ELECTRONIC SIREN & PA SYSTEM Model 4200

THE COMMISIONER TM 200 WATT ELECTRONIC SIREN & PA SYSTEM Model 4200 THE COMMISIONER TM 200 WATT ELECTRONIC SIREN & PA SYSTEM Model 4200 Your purchase of a Wolo electronic siren, THE COMMISIONER, is the perfect choice for reliable service. THE COMMISIONER is manufactured

More information

SA SIREN AMPLIFIER WITH MECHANICAL TONE

SA SIREN AMPLIFIER WITH MECHANICAL TONE Carson Manufacturing Co., Inc. 5451 North Rural Street Indianapolis, IN 46220 Phone: (888) 577-6877 Fax: (317) 254-2667 www.carsonsirens.com SA-500-27 SIREN AMPLIFIER WITH MECHANICAL TONE Y P W OUTPUT

More information

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN Carson MANUFACTURING COMPANY, INC. CARSON MANUFACTURING CO., INC. 5451 NORTH RURAL STREET INDIANAPOLIS, IN 46220 (888) 577 6877 www.carsonsirens.com TECHNICAL BULLETIN RADIO MAN SIREN PA VOL SA400 WAIL

More information

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN Carson MANUFACTURING COMPANY, INC. CARSON MANUFACTURING CO., INC. 5451 NORTH RURAL STREET INDIANAPOLIS, IN 46220 (888) 577 6877 www.carsonsirens.com TECHNICAL BULLETIN MAN WAIL OFF ON PA VOL SA400 YELP

More information

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures. ENGINEERING COMPANY INC. 1 Winthrop Road Chester, Connecticut 0-0 Phone: (0) 2-0 Fax: (0) 2-07 Internet: www.whelen.com Sales e-mail: autosale@whelen.com Canadian Sales e-mail: autocan@whelen.com Customer

More information

640 Series Advanced Remote Vehicle Security System

640 Series Advanced Remote Vehicle Security System 640 Series Advanced Remote Vehicle Security System WWW.ULTRASTARTERS.COM FCC/ID Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: (1) This device

More information

PM100/PM100E PLANTER MONITOR. Operator s Manual

PM100/PM100E PLANTER MONITOR. Operator s Manual PM100/PM100E PLANTER MONITOR Operator s Manual TABLE OF CONTENTS Safety Notices... 1 Introduction... 3 System Overview... 3 Installation... 5 Console Mounting... 5 Monitor and Power Connections... 5 Console

More information

400 SERIES REMOTE SIREN WITH REMOTE ROTARY CONTROL PANEL ETSA481RSR - 100W ETSA482RSR - 200W

400 SERIES REMOTE SIREN WITH REMOTE ROTARY CONTROL PANEL ETSA481RSR - 100W ETSA482RSR - 200W 400 SERIES REMOTE SIREN WITH REMOTE ROTARY CONTROL PANEL ETSA481RSR - 100W ETSA482RSR - 200W Introduction The ETSA48(X)RSR is a remote mounted all in one siren and light controller. It comes in 2 styles

More information

Destiny Destiny Owners Manual

Destiny Destiny Owners Manual Destiny 4100 Destiny 4100 Owners Manual TABLE OF CONTENTS INTRODUCTION Control Panel...3 Detection Devices...3 Telephone Keypads...3 GLOSSARY... 4-5 LOCAL PHONE ACCESS Using Your Telephones As Keypads...6

More information

SPECTRA 1727 USER S GUIDE

SPECTRA 1727 USER S GUIDE SPECTRA 1727 USER S GUIDE TABLE OF CONTENTS 1.0 INTRODUCTION... 3 2.0 BASIC OPERATION... 4 2.1 Auditory Feedback...4 2.2 Keypad Indicator Lights...6 2.3 Zone Display...6 2.4 Alarm Memory Display...6 3.0

More information

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling INSTRUCTION MANUAL TS21 2 Heating and 1 Cooling WELCOME TO Flexible applications - Universal and easy to install in residential or commercial environments. Advanced features - Precision electronics provide

More information

INSTRUCTION MANUAL P Heating and 1 Cooling

INSTRUCTION MANUAL P Heating and 1 Cooling REPLACEMENT COMPONENTS DIVISION CARRIER CORPORATION www.totaltouch.info Technical Support: 1-866-90TOUCH (1-866-908-6824) INSTRUCTION MANUAL P286-1200 2 Heating and 1 Cooling Physical Dimensions Case:

More information

INSTALLATION AND INSTRUCTION MANUAL SS867/LCS869. SS W REMOTE HAND HELD SIREN LCS W REMOTE HAND HELD SIREN w/ LIGHT CONTROLS

INSTALLATION AND INSTRUCTION MANUAL SS867/LCS869. SS W REMOTE HAND HELD SIREN LCS W REMOTE HAND HELD SIREN w/ LIGHT CONTROLS INSTALLATION AND INSTRUCTION MANUAL SS867/LCS869 SS867-100W REMOTE HAND HELD SIREN LCS869-100W REMOTE HAND HELD SIREN w/ LIGHT CONTROLS A Division of Star Headlight & Lantern Co., Inc. PLIT463 REV. A 9/27/11

More information

Premier Hazard STC Instructions

Premier Hazard STC Instructions PREMIER HAZARD Ltd Bessingby Industrial Estate Bridlington YO16 4SJ Tel: +44 (0) 113 239 1111 Fax: +44 (0) 113 239 1131 www.premierhazard.co.uk info@premierhazard.co.uk Premier Hazard STC Instructions

More information

Protégé Eclipse LED Keypad User Manual PRT-KLES

Protégé Eclipse LED Keypad User Manual PRT-KLES Protégé Eclipse LED Keypad User Manual PRT-KLES The specifications and descriptions of products and services contained in this manual were correct at the time of printing. Integrated Control Technology

More information

Eclipse 8 & Eclipse NH

Eclipse 8 & Eclipse NH FEDERAL SIGNAL CORPORATION Eclipse 8 & Eclipse NH ELECTRO-MECHANICAL DC POWER SIRENS INSTALLATION AND OPERATING INSTRUCTIONS Copyright 2005 Federal Signal Corporation 255368B1 04/06 IMPORTANT NOTICE Federal

More information

Electronic Siren System Installation, Maintenance, and Service Manual

Electronic Siren System Installation, Maintenance, and Service Manual Electronic Siren System Installation, Maintenance, and Service Manual 255406B REV. B 312 Printed in U.S.A. blank page Contents Chapter 1 Safety Messages for Installers and Operators...5 Safety Messages

More information

Automotive: Sirens/Switches

Automotive: Sirens/Switches ENGINEERING COMPANY INC. 51 Winthrop Road Chester, Connecticut 06412-064 Phone: (60) 526-9504 Fax: (60) 526-407 Internet: www.whelen.com Sales e-mail: autosale@whelen.com Canadian Sales e-mail: canadiansales@whelen.com

More information

Automotive: Sirens/Switches

Automotive: Sirens/Switches ENGINEERING COMPANY INC 51 Winthrop Road Chester, Connecticut 06412-0684 Phone: (860) 526-9504 Fax: (860) 526-4078 Internet: wwwwhelencom Sales e-mail: autosale@whelencom Canadian Sales e-mail: canadiansales@whelencom

More information

Typhoon Full Function C-4017

Typhoon Full Function C-4017 Typhoon Instruction Manual Typhoon Full Function C-4017 Typhoon Handheld C-5017 Feniex Product Copyrights This price List and the mentioned Feniex products include or describe copyrighted Feniex material.

More information

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures. ENGINEERING COMPANY INC. Route 145, Winthrop Road, Chester, Connecticut 06412 Phone: (860) 5269504 Fa: (860) 5264078 Internet: www.whelen.com Sales email: autosale@whelen.com Canadian Sales email: autocan@whelen.com

More information

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures. ENGINEERING COMPANY INC. 51 Winthrop Road Chester, Connecticut 06412-0684 Phone: (860) 526-9504 Fax: (860) 526-4078 Internet: www.whelen.com Sales e-mail: autosale@whelen.com Canadian Sales e-mail: autocan@whelen.com

More information

LCD and 16-Zone LED Keypads. User s Manual

LCD and 16-Zone LED Keypads.   User s Manual LCD and 16-Zone LED Keypads 1689 1641 16-Zone LED Keypad LCD Keypad User s Manual TABLE OF CONTENTS 1.0 INTRODUCTION...3 2.0 BASIC OPERATION...4 2.1 Keypad Indicator Lights... 4 2.2 Visual Feedback...

More information

400 SERIES REMOTE AMPLIFIER SIREN W/ HANDHELD REMOTE ETSA461HPP - 100W ETSA462HPP - 200W

400 SERIES REMOTE AMPLIFIER SIREN W/ HANDHELD REMOTE ETSA461HPP - 100W ETSA462HPP - 200W 00 SERIES REMOTE AMPLIFIER SIREN W/ HANDHELD REMOTE ETSA61HPP - 100W ETSA62HPP - 200W PSRNANR1 PSRNANR2 100W 200W Amplifier Box Microphone, Lights and Siren Controller HANDHELD SIREN CTROLLER WARNING HIGH

More information

Static Pressure Control

Static Pressure Control The (model SPC-2) is a fully programmable controller that provides extensive flexibility for your curtain or awning control needs. The SPC-2 automatically controls the pressure in a room by operating a

More information

STORM PRO Model # - C-4014, C Storm Pro- Instruction Manual 100W 200W V.3. This instruction manual serves as a guide for the Storm Pro.

STORM PRO Model # - C-4014, C Storm Pro- Instruction Manual 100W 200W V.3. This instruction manual serves as a guide for the Storm Pro. Storm Pro- Instruction Manual 100W 200W STORM PRO Model # - C-4014, C-4015 This instruction manual serves as a guide for the Storm Pro. IMPORTANT! Please read through all provided instructions and any

More information

XCEL SERIES SIREN WARNING IMPORTANT:

XCEL SERIES SIREN WARNING IMPORTANT: XCEL SERIES TM SIREN PATENTED. See https://secure.code3pse.com/patents/ WARNING Sirens produce loud sounds that may damage hearing Wear hearing protection when testing Use siren only for emergency response

More information

Typhoon Full Function C-4017

Typhoon Full Function C-4017 Typhoon Instruction Manual Typhoon Full Function C-4017 Typhoon Handheld C-5017 Feniex Product Copyrights This price List and the mentioned Feniex products include or describe copyrighted Feniex material.

More information

FreezeAlarm. General Description FA-D /FA-D-AAB. Applications. Features. Specifications. Dimensions

FreezeAlarm. General Description FA-D /FA-D-AAB. Applications. Features. Specifications. Dimensions Innovative Technologies in Custom Electronic Design & Manufacturing General Description The FA-D (fahrenheit) and FA-D-AAB (celsius) FreezeAlarm monitors temperature, power status, security or an external

More information

Automotive: Sirens/Switches

Automotive: Sirens/Switches ENGINEERING COMPANY INC. 51 Winthrop Road Chester, Connecticut 06412-0684 Phone: (860) 526-9504 Fax: (860) 526-4078 Internet: www.whelen.com Sales e-mail: autosale@whelen.com Canadian Sales e-mail: canadiansales@whelen.com

More information

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures. ENGINEERING COMPANY INC. Winthrop Road Chester, Connecticut 06-068 Phone: (860) 6-90 Fax: (860) 6-078 Internet: www.whelen.com Sales e-mail: autosale@whelen.com Canadian Sales e-mail: autocan@whelen.com

More information

Non-Programmable Digital Thermostat

Non-Programmable Digital Thermostat OWNER'S MANUAL MODEL P474-0140 Non-Programmable Digital Thermostat HEAT PUMP THERMOSTAT 2 HEAT, 1 COOL emergency aux. heat normal energy save Fan On Fan Auto Millivolt Compatible Battery or System Powered

More information

Auto Dialer. Manual E-921APQ E-921GPQ

Auto Dialer. Manual E-921APQ E-921GPQ Troubleshooting: Auto dialer will not arm/disarm Auto dialer will not dial out Unit doesn t respond to a call-back Difficulty in activating room monitor by telephone remote control Make sure that you have

More information

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN Carson MANUFACTURING COMPANY, INC. CARSON MANUFACTURING CO., INC. 5451 NORTH RURAL STREET INDIANAPOLIS, IN 46220 (888) 577 6877 www.carsonsirens.com TECHNICAL BULLETIN OFF 1 2 3 PA VOL PWR OFF 1 2 3 4

More information

Automatic Phone-Out Home Monitoring Systems

Automatic Phone-Out Home Monitoring Systems Automatic Phone-Out Home Monitoring Systems Power Outage, Freeze and Flood Alarm Product Description Model Number: THP201 These monitoring systems are intended to monitor homes, cabins, and other premises

More information

MODULATOR SERIES B SPEAKER ARRAYS

MODULATOR SERIES B SPEAKER ARRAYS MODULATOR SERIES B SPEAKER ARRAYS INSTALLATION AND MAINTENANCE INSTRUCTIONS 25500059A 1/13 Copyright 2013 Federal Signal Corporation - i - SAFETY NOTICES People s lives depend on your selection of suitable

More information

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL INSTALLATION AND OPERATION GUIDE INTRODUCTION The NSI 804CP and 808CP represents a key part of a state of the art, total lighting control system. Combined with

More information

Carson Manufacturing Co., Inc North Rural Street Indianapolis, IN Phone: (888) Fax: (317)

Carson Manufacturing Co., Inc North Rural Street Indianapolis, IN Phone: (888) Fax: (317) Carson Manufacturing Co., Inc. 5451 North Rural Street Indianapolis, IN 46220 Phone: (888) 577-6877 Fax: (317) 254-2667 www.carsonsirens.com TECHNICAL BULLETIN MANUAL/ THUNDER PA VOL YELP WAIL STANDBY

More information

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures. ENGINEERING COMPANY INC. 5 Winthrop Road Chester, Connecticut 06-068 Phone: (860) 56-950 Fax: (860) 56-078 Internet: www.whelen.com Sales e-mail: autosale@whelen.com Canadian Sales e-mail: canadiansales@whelen.com

More information

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN OFF/ON PA VOL

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN OFF/ON PA VOL Carson MANUFACTURING COMPANY, INC. CARSON MANUFACTURING CO., INC. 5451 NORTH RURAL STREET INDIANAPOLIS, IN 46220 (888) 577 6877 www.carsonsirens.com TECHNICAL BULLETIN OFF/ON RADIO HRN/TT SIREN PA VOL

More information

Installation and Programming manual INSTALLATION MANUAL E PROGRAMMING INSTALLAZIONE PROGRAMMAZIONE

Installation and Programming manual INSTALLATION MANUAL E PROGRAMMING INSTALLAZIONE PROGRAMMAZIONE SELF-POWERED S I R E N A A U SOUNDER/FLASHER T O A L I M E N T A T A FOR P E R OUTDOOR E S T E R NUSE O INSTALLATION MANUALE AND DI PROGRAMMING INSTALLAZIONE MANUAL E PROGRAMMAZIONE 1 Table of contents

More information

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm Page 1 of 8 General Overview Thank you for purchasing an Ion Genesis controller. Take the time to read the instructions carefully before using this appliance. We strongly recommend that you keep this instruction

More information

HEIGHTS KEY LOCK & SAFE 920 San Mateo NE Albuquerque, NM Contact us for more information

HEIGHTS KEY LOCK & SAFE 920 San Mateo NE Albuquerque, NM Contact us for more information HEIGHTS KEY LOCK & SAFE 920 San Mateo NE Albuquerque, NM 87108 Contact us for more information Home Page FEATURES AND PROGRAMMING GUIDE COMMANDANDCONTROLSERIES DOOR-GARD COMMAND AND CONTROL SERIES keypads

More information

Beacon 800 Gas Monitor Operator s Manual

Beacon 800 Gas Monitor Operator s Manual Beacon 800 Gas Monitor Operator s Manual Part Number: 71-0037RK Revision: F Released: 4/18/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be

More information

INSTALLER S & OWNER S MANUAL

INSTALLER S & OWNER S MANUAL INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER Part No. 4028539 Dehumidifier & Ventilation System Controller 4201 Lien Rd Madison, WI 53704 TOLL-FREE 1-800-533-7533 www.thermastor.com

More information

Freeze Alarm. General Description VD-6300-MCS / VD-6301-MCS. Applications. Features. Specifications. Dimensions

Freeze Alarm. General Description VD-6300-MCS / VD-6301-MCS. Applications. Features. Specifications. Dimensions Innovative Technologies in Custom Electronic Design & Manufacturing General Description The VD-6300-MCS Freeze Alarm monitors temperature, power status, security or an external contact, and offers remote

More information

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...

More information

flexibility programmed settings.

flexibility programmed settings. Phason Natural Ventilation Control The Natural Ventilation Control (NVC-2) is a fully programmable controller that provides extensive flexibility for your curtain or awning control needs. The NVC-2 automatically

More information

8VHU*XLGH K4254V3 6/01

8VHU*XLGH K4254V3 6/01 8QLYHUVDO9RLFH 6\VWHP 896 896²(8$ 8VHU*XLGH K4254V3 6/01 Table of Contents ABOUT THE UNIVERSAL VOICE SYSTEM (UVS)...3 USER OPERATION SUMMARY...4 2-WAY VOICE OPERATION (CENTRAL STATION)...6 2-WAY VOICE

More information

TrueClean ToteCleaner

TrueClean ToteCleaner TrueClean ToteCleaner Installation, Operation, and Maintenance Manual www.trueclean.us TrueClean Check Valve Table of Contents Introduction.... 1 About... 1 Warranty... 2 Safety... 3 Important Safety Information....

More information

Installation and Operation Instructions 1000 Series Siren & Controller

Installation and Operation Instructions 1000 Series Siren & Controller Installation and Operation Instructions 1000 Series Siren & Controller ` WARNING! Failure to install or use this product according to manufacturer s recommendations may result in property damage, serious

More information

Introduction... 1 System Overview... 1 System Diagram... 2

Introduction... 1 System Overview... 1 System Diagram... 2 TABLE OF CONTENTS Introduction... 1 System Overview... 1 System Diagram... 2 Installation... 3 Console Mounting... 3 Monitor And Power Connections... 3 ASM II Console Main Harness... 4 Module Mounting...

More information

218 Trademark Dr Buda Texas STL Apex 150 Watt Siren Operation Manual and Instructions

218 Trademark Dr Buda Texas STL Apex 150 Watt Siren Operation Manual and Instructions STL Apex 150 Watt Siren Operation Manual and Instructions Congratulations, you are the owner of a STL Apex 150 Watt Siren! Your siren is equipped with the latest technology and features at the best value

More information

SS741MG-11 DUAL AMPLIFIER SIREN. Installation and Operating Instructions PLITSTR250 REV F 5/15/17

SS741MG-11 DUAL AMPLIFIER SIREN. Installation and Operating Instructions PLITSTR250 REV F 5/15/17 SS741MG-11 11 DUAL AMPLIFIER SIREN Installation and Operating Instructions PLITSTR250 REV F 5/15/17 Installation Information MODEL: SS741MG-11 Serial #: PURCHASE DATE: INSTALLATION DATE: INSTALLER: DEALER:

More information

636 and 646 Keypads. User s Manual

636 and 646 Keypads. User s Manual 636 and 646 Keypads 636 646 User s Manual Table Of Contents Basic Operation... 2 Access Codes... 4 Arming & Disarming... 5 Panic Zones... 11 Key Access Programming... 12 Additional Features... 13 Trouble

More information

Mark 25 Ultrapure Water Conductivity Analyzer

Mark 25 Ultrapure Water Conductivity Analyzer Martek Instruments, Inc. Mark 25 Ultrapure Water Conductivity Analyzer Instruction Manual WARRANTY POLICY Unless otherwise stated, MARTEK INSTRUMENTS, INC. warrants this equipment to be free from defects

More information

10-Zone Spectra LED Keypads

10-Zone Spectra LED Keypads 10-Zone Spectra LED Keypads User s Guide TABLE OF CONTENTS Introduction... 5 Basic Operation... 6 Auditory Feedback... 6 Keypad Indicator Lights... 8 Zone Display... 8 Alarm Memory Display... 8 Trouble

More information

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø) Model: 3200FA (220v-240V 1Ø) Voltage Supply to Machine:

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø) Model: 3200FA (220v-240V 1Ø) Voltage Supply to Machine: OPERATIONAL & INSTRUCTION MANUAL Model: 2400FA (120v 1Ø) Model: 3200FA (220v-240V 1Ø) Voltage Supply to Machine: L1 to L2: L1 to Ground: L2 to Ground UltraSonic LLC P.O. Box 54081 Cincinnati, Ohio 45255

More information

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products: Model 2102 Gas Alarm Panel APPLICABILITY & EFFECTIVITY This manual provides instructions for the following Sierra Monitor products: Model Description 2102-00 Alarm Panel 2 Channel 2102-01 Alarm Panel 2

More information

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access II User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access Part #2139703 Rev. G II Table of Contents Introduction...3 Elevator Overview...4 Description of Features...5-7

More information

LED Traffic Clearing Light

LED Traffic Clearing Light LED Traffic Clearing Light Model LEDTCL97 Installation and Service Instructions 25500469 A Rev. A0 0818 Printed in U.S.A. Limited Warranty This product is subject to and covered by a limited warranty,

More information

INSTALLER S & OWNER S MANUAL

INSTALLER S & OWNER S MANUAL INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000R Part No. 4028407 Dehumidifier & Ventilation System Controller 4201 Lien Road, Madison, WI 53704 TOLL-FREE (800)-533-7533

More information

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! - Security System Owner s Manual Interactive Technologies Inc. 2266 North 2nd Street North St. Paul, MN 55109 FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

Long Range Radio Alarm Transmitter

Long Range Radio Alarm Transmitter W A R N I N G Please refer to the System Installation Manual for information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. TM

More information

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures. ENGINEERING COMPANY INC. 1 Winthrop Road Chester, Connecticut 012-0 Phone: (0) 2-90 Fax: (0) 2-07 Internet: www.whelen.com Sales e-mail: autosale@whelen.com Canadian Sales e-mail: autocan@whelen.com Customer

More information

Installation Manual February Opticom Infrared System. Model 575 Confirmation Light Kit

Installation Manual February Opticom Infrared System. Model 575 Confirmation Light Kit Installation Manual February 2008 Opticom Infrared System Model 575 Confirmation Light Kit Installation i Table of Contents 1 About This Manual... 1 1.1 Purpose of Manual... 1 1.2 Manual Conventions...

More information

PowerWave-16. Users Operating and Programming Guide Version P/N Rev. B N.A July 2002

PowerWave-16. Users Operating and Programming Guide Version P/N Rev. B N.A July 2002 ELECTRONIC ENGINEERING LTD. PowerWave-16 16 zone Control panel Communicator Users Operating and Programming Guide Version 6.20 P/N 7121240 Rev. B N.A July 2002 Contents Introduction...4 Meet the Crow Alarm

More information

INSTRUCTION MANUAL P Heating and 2 Cooling with Humidification and De-humdification

INSTRUCTION MANUAL P Heating and 2 Cooling with Humidification and De-humdification REPLACEMENT COMPONENTS DIVISION CARRIER CORPORATION www.totaltouch.info Technical Support: 1-866-90TOUCH (1-866-908-6824) INSTRUCTION MANUAL P286-1400 3 Heating and 2 Cooling with Humidification and De-humdification

More information

CA 120 Owners Manual of 10

CA 120 Owners Manual of 10 CA 120 Owners Manual 1 of 10 Your System has many features and available options some of which are selected at time of installation. Consult your installing dealer for options that may have been installed

More information