1 Appendix A Compatible Devices A.1 Notification Appliances For proper operation, you must use polarized devices with a Model k ohm EOL resistor on each loop. All supervised notification applicances used with the control panel must be polarized. Note: Not all devices can use the Sync feature, be sure to check Table A-1 to ensure the device you have chosen will work with this feature. Do not exceed 3 Amps per output. Table A-1 below lists notification appliances compatible with the fire alarm control panel. Appliances which can be synchronized indicate the type of snyc available in the columns marked Audio and/or Visual. AMSECO Faraday SH24W / SL24W H24W 446 Vibrating Bell 476 Vibrating Bell 477 Single Stroke Bell M. -R, -T, -Y, -Z 2701 Series 2705 Series 2820 Snyc Temporal / 2821 Snyc Temporal / Multi-Tone ) 5336 Multi-Tone / 5337 Multi-Tone / 5338 Multi-Tone / 5343 Single Tone / 5346 Electronic with 5347 Electronic with 5348 Single Tone / Tone / Tone / Tone / Tone / Tone / with Sync A-1

2 Model IFP-100 Installation and Operation Manual Faraday Tone / with Sync Tone / with Sync Tone / with Sync 5405 Sync Control Unit 5508 Single Gang Sync Square Sync Square Sync / 6227 / 6228 / 6243 Electron-Mechanical 6244 Electron-Mechanical 6245 Electron-Mechanical 6246 Electron-Mechanical / 6247 Electron-Mechanical / 6248 Electron-Mechanical / 6300 Mini Mini Mini Mini-/ 6311 Mini-/ 6312 Mini-/ 6314 Series -M, -R, -T, -Y, -Z 6320 Sync Mini / 6321 Sync Mini / 6322 Mini /Sync Tone Electronic Signal/ A

3 Compatible Devices FCI C Mini C Mini BLV-6 Vibrating Bell BLV-10 Vibrating Bell BLVCH Vibrating H12/24-FC H12/24W-FC H12/24K-FC HC12/24-FC HC12/24W-FC HC12/24K-FC P2415-FC / P2415W-FC / P2415K-FC / P FC / P241575W-FC / P241575F-FC / P241575K-FC / P2430-FC / P2430W-FC / P2430K-FC / P2475-FC / P2475W-FC / P2475K-FC / P24110-FC / P24110W-FC / P24110K-FC / S2415-FC S FC S241575W-FC S241575K-FC S2430-FC S2430W-FC S2430K-FC S2475-FC S2475W-FC S2475K-FC S24110-FC S24110W-FC S24110K-FC MDL-FC Sync. Module MDLW-FC Sync. Module A-3

4 Model IFP-100 Installation and Operation Manual Federal Signal Gentex System Sensor 450 VALS / GX90-4 GXS GXS GX90S-4-15 GX90S HG124 SHG / SHG24-15 / GEC Series /s GES Series s GEH s GMH-24-X GMS-24-X / G0T24 G0S24-X ST/HS Commander Series s & /s WGMS-24-X / H12/24 HC12/24 MASS241 / MASS24110ADA / MASS2415ADA / MASS2475ADA / P2415 / P / P2430 / P2475 / P24110 / S2415 S S2430 S24110 SS24110ADA SS2415ADA SS2475ADA PS2415ADA Mini-/ PS241575ADA Mini-/ PS24110ADA Mini-/ A

5 Compatible Devices System Sensor Wheelock PS2475ADA Mini-/ MDL Sync. Module MDLW Sync. Module 46T-G4-24-R Bell 46T-G6-24-R Bell 46T-G10-24-R Bell 46T-G6-24-WS-24-HF-R /Bell 46T-G10-24-WS-24-HF-R /Bell 46T-G6-24-WH-24-HF-R /Bell 46T-G10-24-WH-24-HF-R /Bell 7001T-12\24-W-FR 7002T-12\24-W-FR AES-DL1-R Multitone AES-EL1-R Multitone AES-DL1-WS-24-VF-R Multitone AES-EL1-WS-24-VF-R Multitone AES-DL1-WH-24-VF-R Multitone AES-EL1-WH-24-VF-R Multitone AES-DL1-WM-24-VF-R Multitone AES-EL1-WM-24-VF-R Multitone AH-24-R AH-24WP-R AMT-12\24-R AMT-24-LS-VFR AMT-24-LSM-VFR AMT-24-IS-VFR AS-24MCW-FR AS-24MCW-FW AS-2415W-FR AS-2415C-FW AS W-FR AS-2475C-FW AS-24100C-FW AS-2430W-FR AS-2430C-FW AS-2475W-FR AS-24110W-FR ASWP-2475W-FR SM-12\24-R Controller DSM-12\24-R Controller CF-BF A-5

6 Model IFP-100 Installation and Operation Manual Wheelock CF-BF1-R CH-CF1 CH-CF1-R CH-CF1-W CH-DF1 CH-DF1-R CH-BF1-WS-24-HF-R CH-CF1-LS-24 CH-CF1-MS-24 CH-CF1-IS-24 CH-CF1-LS-24-CFW CH-CF1-MS-24-CFW CH-CF1-IS-24-CFW CH-CF1-WS-24-CF-W CH-DF1-LS-24 CH-DF1-MS-24 CH-DF1-IS-24 CH-DF1-LS-24-VFR CH-DF1-LSM-24-VFR CH-DF1-MS-24-VFR CH-DF1-IS-24-VFR CH-DF1-WM-24-VFR CH-DF1-WS-24-VF-R DSM-12/24 EH-DL1-R EH-EL1-R Electronic EHS-DL1-W-VF-R EHS-EL1-W-VF-R EH-DL1-WS-24-VF-R EH-EL1-WS-24-VF-R EH-DL1-WH-24-VF-R EH-EL1-WH-24-VF-R EH-DL1-WM-24-VF-R EH-EL1-WM-24-VF-R HSW-24-HFR HS2W-24-HFR HSPW-24-HFR IS-24-VFR Sync Module Electronic Electronic (single input) (single input) (dual input) (dual input) (dual input) (dual input) (dual input) (dual input) Remote Remote Remote Remote A

7 Compatible Devices Wheelock IS1-24-VFR IS3-24-VFR ISP-24-HFR LS-24-VFR LS1-24-VFR LS3-24-VFR LSP-24-HFR LSM-24-VFR LS1M-24-VFR LS3M-24-VFR LSPM-24-VFR MS-24-VFR MS1-24-VFR MS3-24-VFR MSP-24-HFR MB-G6-24-R MB-G10-24-R MBS-G6-24-W-HF-R MBS-G10-24-W-HF-R MIZ-24-R MIZ-24-W MIZ-24-LS-VFR MIZ-24-LSM-VFR MIZ-24-MS-VFR MIZ-24-HSW-HFR MIZ-24-IS-VFR MIZ-24-WS-VF-R MIZ-24-WS-VF-W MIZ-24-WH-VF-W MIZ-24-WM-VF-W MT-12/24-R MT-24-LS-VFR MT-24-LSM-VFR MT-24-MS-VFR MT-24-IS-VFR MT-24-SL-VFR MT-24-SLM-VFR MT-24-WM MT-24-WM-VFR Remote Remote Remote Remote Remote Remote Remote Remote Remote Remote Remote Remote Remote Remote Remote Motor Bell Motor Bell Motor Bell with Motor Bell with Mini- Mini- Mini-/ Mini-/ Mini-/ Mini-/ Mini-/ Mini-/ Mini-/ Mini-/ Mini-/ Synch. Multitone A-7

8 Model IFP-100 Installation and Operation Manual Wheelock NS-24MCM-FR s NS-24MCW-FW s NS-2415W-FR s NS W-FR s NS-2430W-FR s NS-2475W-FR s NS-24110W-FR s NS4-24MCW-FR s NS4-24MCW-FW s NS W-FR s NH-12/24-R RS-2415-HFR RSP-2415-VFR RS VFR RSP VFR RS-2430-VFR RS-2430-HFR RS-2475-VFR RSP-2475-HFR RS HFR RSP HFR SL-24-VFR Synchronized Remote SL1-24-VFR Synchronized Remote SL3-24-VFR Synchronized Remote SLP-24-VFR Synchronized Remote SLM-24-VFR Synchronized Remote SL1M-24-VFR Synchronized Remote SL3M-24-VFR Synchronized Remote SLPM-24-VFR Synchronized Remote SHW-24-VFR Synchronized Remote SH2W-24-VFR Synchronized Remote SHPW-24-VFR Synchronized Remote SCM-24-R Controller for Synchronized s A

9 Compatible Devices Wheelock SM-12/24-R SR-2415-VFR SRP-2415-HFR SR VFR SRP VFR SR-2475-VFR SR-2475-HFR SR HFR SRP HFR V7001T-12\24-W-FR WM3T-24-FR WM3T-24-VFR WS1T-24-FR WS3T-24-FR WST-24-FR Sync Module Sync Sync Sync Sync Sync Sync Sync Sync Remote Remote A.2 Door Holder Device The following UL listed door holder can be used with the control panel: Model 1400 from Door Control International A-9

10 Model IFP-100 Installation and Operation Manual A

SILENT KNIGHT Installation Manual. Distributed Power Module. Part Number G, 08/03

SILENT KNIGHT Installation Manual. Distributed Power Module. Part Number G, 08/03 SILENT KNIGHT 5495 Distributed Power Module Installation Manual Part Number 151161G, 08/03 Content Section 1 Introduction...1 Section 2 UL Requirements...2 Section 3 System Overview...3 3.1 Terminal Descriptions

More information

Honeywell Power Products

Honeywell Power Products Honeywell Power Products HPF602ULADA 66 Amp NAC Expander INSTALLATION & OPERATION MANUAL Honeywell Power Products 12 Clintonville Road Northford, CT 06472-1653 USA P/N 151341 Rev J Installation Precautions

More information

INTELLIKNIGHT 5895XL. Installation and Operations Manual. Intelligent Power Module for the 5820XL Systems. Part Number Rev E

INTELLIKNIGHT 5895XL. Installation and Operations Manual. Intelligent Power Module for the 5820XL Systems. Part Number Rev E INTELLIKNIGHT 5895XL Intelligent Power Module for the 5820XL Systems Installation and Operations Manual Part Number 151142 Rev E Contents Section 1 Overview... 1-1 1.1 5895XL Description... 1-1 1.1.1

More information

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL THE GAMEWELL COMPANY PN: 71981 60 PLEASANT STREET ISSUE A ASHLAND, MA 01721 3/22/2001 This page intentionally blank ii

More information

Silent Knight Device Compatibility

Silent Knight Device Compatibility Silent Knight Device Compatibility SK-5208 Conventional FACP SK-2 / SK-4 Conventional FACPs 5495 6A Conventional Distributed Power Supply 5496 6A Intelligent Distributed Power Supply 5499 9A Conventional

More information

ZNS MICROPROCESSOR BASED CONVENTIONAL FIRE ALARM CONTROL PANEL. Installation & Operation Manual

ZNS MICROPROCESSOR BASED CONVENTIONAL FIRE ALARM CONTROL PANEL. Installation & Operation Manual ZNS MICROPROCESSOR BASED CONVENTIONAL FIRE ALARM CONTROL PANEL Installation & Operation Manual The Gamewell Company 60 Pleasant Street Part No. 71774 Ashland, MA 01721 Issue 4 12/4/98 PROPRIETARY MATERIAL

More information

MODEL Intelligent Power Module. Installation and Operations Manual. Document /12/10 Rev: E1 P/N :E1 ECN:

MODEL Intelligent Power Module. Installation and Operations Manual. Document /12/10 Rev: E1 P/N :E1 ECN: MODEL 5496 Intelligent Power Module Installation and Operations Manual Document 151276 08/12/10 Rev: E1 P/N 151276:E1 ECN: 10-484 Contents Section 1 Overview... 1-1 1.1 5496 Description... 1-1 1.2 Agency

More information

MODEL Distributed Power Module. Installation and Operations Manual. Part Number Rev L

MODEL Distributed Power Module. Installation and Operations Manual. Part Number Rev L MODEL 5495 Distributed Power Module Part Number 151161 Rev L Installation and Operations Manual Contents Section 1 Introduction...1 Section 2 UL Requirements...2 2.1 ULC Requirements...2 Section 3 System

More information

UL Online Certifications Directory

UL Online Certifications Directory UL Online Certifications Directory Home Quick Guide Contact Us UL.com UUKC.S5391 Signaling Appliances and Equipment for the Hearing Impaired Page Bottom Signaling Appliances and Equipment for the Hearing

More information

Fire Alarm Control Panels

Fire Alarm Control Panels Fire Alarm Control Panels Device Compatability Guide LT-1007SUM Rev.2 Compatability Guide Table of Contents SFC-500 Series Compatible Addressable Devices (UL Listed)... 1 Analog/Addressable Devices...

More information

FA-101U Fire Alarm Control Panel

FA-101U Fire Alarm Control Panel FA-101U Fire Alarm Control Panel INSTALLATION and OPERATION MANUAL LNOTICE All information, documentation, and specifications contained in this manual are subject to change without prior notice by the

More information

Analog fire panels FPA-1000 Family

Analog fire panels FPA-1000 Family Analog fire panels FPA-1000 Family en NAC Compatibility List Analog fire panels NAC compatibility en 3 1 NAC compatibility 1.1 General notes Bosch Security Systems found the following notification appliance

More information

1. POWERPATH Operation

1. POWERPATH Operation 273 Branchport Avenue Long Branch, NJ 07740 (800) 631-2148 www.wheelockinc.com Thank you for using our products. INSTALLATION INSTRUCTIONS MODEL PS-12/24-6 POWERPATH Use this product according to this

More information

UL Online Certifications Directory

UL Online Certifications Directory UL Online Certifications Directory Home Quick Guide Contact Us UL.com ULSZ.E5946 Audible-signal Appliances Page Bottom Audible-signal Appliances See General Information for Audible-signal Appliances COOPER

More information

Johnson Controls, Inc. Device Compatibility Document. Document /18/2009 Rev: J1 P/N 51922:J ECN

Johnson Controls, Inc. Device Compatibility Document. Document /18/2009 Rev: J1 P/N 51922:J ECN Johnson Controls, Inc. Device Compatibility Document Document 51922 9/18/2009 Rev: J1 P/N 51922:J ECN 09-633 Control Panel Circuit Specification LISTED for 8 th Edition Panels and Power Supply Listed for

More information

PFC-3002T Fire Alarm Control Panel

PFC-3002T Fire Alarm Control Panel PFC-3002T Fire Alarm Control Panel INSTALLATION and OPERATION MANUAL L NOTICE All information, documentation, and specifications contained in this manual are subject to change without prior notice by the

More information

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL March 30, 2000 Section: Audio/Visual Devices G-250 SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL System Sensor SpectrAlert Series strobes, horns, and combination horn/strobes are UL listed

More information

Device Compatibility Document

Device Compatibility Document Device Compatibility Document Document 15384 11/05/2013 Rev: BB P/N 15384:BB ECN 13-1007 Table of Contents Control Panel Circuit Specifications...3 Accessories Circuit Specifications...4 Fire Alarm Equipment

More information

Wheelock RSS & RSSP Series

Wheelock RSS & RSSP Series Wheelock RSS & RSSP Series Single- and Multi-Candela Strobes and Strobe Plates DF-51780:A G-520 General Wheelock s patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current

More information

AL602ULADA AL802ULADA AL1002ULADA

AL602ULADA AL802ULADA AL1002ULADA AL602ULADA AL802ULADA AL1002ULADA NAC Power Extenders Application Guide (See Installation Guide for additional information) Rev. 031703 1. General Information (Use this in conjunction with respective Installation

More information

FA-102U Fire Alarm Control Panel

FA-102U Fire Alarm Control Panel FA-102U Fire Alarm Control Panel INSTALLATION and OPERATION MANUAL LNOTICE All information, documentation, and specifications contained in this manual are subject to change without prior notice by the

More information

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control File: S8485 Wiring Diagram This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control Panel. The operation of this product is intended for indoor

More information

Device Compatibility Document

Device Compatibility Document Device Compatibility Document Document 15384 Rev: BH 5/2/2018 ECN:18-133 Table of Contents Control Panel Circuit Specifications...3 Accessories Circuit Specifications...4 Fire Alarm Equipment Controls

More information

IFP-2000 F r a en e h n y h t y PH P D

IFP-2000 F r a en e h n y h t y PH P D IFP-2000 Farenhyt PHD Power Supplies Module 4 Course Objectives At the end of this course you will be able to: Explain the advantages of Conventional Distributed power supplies Explain the advantages of

More information

FireNET Plus Wiring Instructions

FireNET Plus Wiring Instructions FireNET Plus Wiring Instructions This manual provides wiring instructions for the 1 loop and 2 loop version of the FireNET Plus panels, which supports our finest Hochiki s DCP protocol. Note: Refer to

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 031703 Overview: The Altronix AL802ULADA is an extremely cost effective 8 amp voltage regulated

More information

XPS and XNAC Installation Instructions

XPS and XNAC Installation Instructions XPS and XNAC Installation Instructions Introduction This publication describes the installation procedure for 4100-5101 (120 VAC), 4100-5102 (220/230/240 VAC), and 4100-5103 (120 VAC with battery disconnect)

More information

Protect. Alert. Inform.

Protect. Alert. Inform. Life safety & mass notification solutions Product Catalog Protect. Alert. Inform. Leading the industry in advanced technological solutions The performance you rely on Cooper Notification now from Eaton

More information

1 Watt Supervised Self-Amplified Strobe Speakers Round Flush Grille with 75cd Strobe

1 Watt Supervised Self-Amplified Strobe Speakers Round Flush Grille with 75cd Strobe 273 Branchport Avenue Long Branch, N.J. 07740 (800) 631-2148 Thank you for using our products. www.wheelockinc.com INSTALLATION INSTRUCTIONS SUPERVISED SELF-AMPLIFIED STROBE SPEAKERS Use this product according

More information

PSN-1000 & PSN 1000(E) Installation Manual

PSN-1000 & PSN 1000(E) Installation Manual PSN-1000 & PSN 1000(E) Installation Manual Potter Electric Signal Company, LLC St. Louis, MO Customer Service: (866) 240-1870 Technical Support: (866) 956-1211 Fax: (314) 595-6999 www.pottersignal.com

More information

AL800ULADA. NAC Power Extender. Installation Guide

AL800ULADA. NAC Power Extender. Installation Guide AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery

More information

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS SXL Conventional Zone Fire Alarm Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS 4 Zones Expandable to 8 Zones Microprocessor Based Control Factory Programmed Field Configurable 2 Style Y Notification

More information

Mounting Accessories. Notification. See Notes 1 & 8. See Note Thickness: 13/64. (a) universal mounting plate. (f) double-gang, flush (bo)

Mounting Accessories. Notification. See Notes 1 & 8. See Note Thickness: 13/64. (a) universal mounting plate. (f) double-gang, flush (bo) Mounting Accessories Notification (a) universal mounting plate (f) double-gang, flush (bo) AS Mounting (b) single-gang, flush (bo) See Notes 4 Used with Series AMT, AH, AS, HS4, HS, MT, NH, NS, RSS (g)

More information

MOUNTING ACCESSORIES. See Notes 1 & 8. See Note Thickness: 13/64 (A) UNIVERSAL MOUNTING PLATE (F) DOUBLE-GANG, FLUSH (BO) See Notes 4

MOUNTING ACCESSORIES. See Notes 1 & 8. See Note Thickness: 13/64 (A) UNIVERSAL MOUNTING PLATE (F) DOUBLE-GANG, FLUSH (BO) See Notes 4 MOUNTING ACCESSORIES (A) UNIVERSAL MOUNTING PLATE (F) DOUBLE-GANG, FLUSH (BO) AS Mounting (B) SINGLE-GANG, FLUSH (BO) See Notes 4 Used with Series AMT, AH, AS, HS4, HS, MT, NH, NS, RSS (G) DOUBLE-GANG,

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 042010 Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).

More information

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS CSM-4 Controllable Signal/Releasing Module ENGINEER AND ARCHITECT SPECIFICATIONS Supervised Alarm Notification Appliance Circuits Operates Audible or Visual Devices Class A (Style Z) or Class B (StyleY)

More information

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card XP6-C Six Circuit Supervised Control Module and SYNC-1 Accessory Card General NOTIFIER s XP6-C six-circuit supervised control module provides intelligent alarm systems with supervised monitoring of wiring

More information

Mounting Accessories. Notification. See Notes 1 & 8. See Note Thickness: 13/64. (a) universal mounting plate. (f) double-gang, flush (bo)

Mounting Accessories. Notification. See Notes 1 & 8. See Note Thickness: 13/64. (a) universal mounting plate. (f) double-gang, flush (bo) Mounting Accessories Notification (a) universal mounting plate (f) double-gang, flush (bo) AS Mounting (b) single-gang, flush (bo) See Notes 4 Used with Series AMT, AH, AS, HS4, HS, MT, NH, NS, RSS (g)

More information

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev Installation Guide for AL800UL-ADA NAC Power Extender Rev. 090500 Overview: The Altronix AL800UL-ADA is an extremely cost effective 8 amps voltage regulated remote power supply /battery charger. The AL800UL-ADA

More information

Harrington Signal HS-3100/3200 Fire Alarm Control Unit

Harrington Signal HS-3100/3200 Fire Alarm Control Unit HARRINGTON SIGNAL INC. FIRE ALARM Harrington Signal HS-3100/3200 Fire Alarm Control Unit Installation Manual Revision 2 January 2009 Document # LT-2000HAR Table of Contents 1.0 Technical Information...

More information

Signature Series Auto-Sync Output Module (CC1S)

Signature Series Auto-Sync Output Module (CC1S) Signature Series Auto-Sync Output Module (CC1S) Product description Mounting The Signature Series can be mounted in a North American 2-1/2 in (64 mm) deep 2-gang box or a standard 4 in square box 1-1/2

More information

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X AL1002ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 071508X Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).

More information

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev Altronix Corp. 140 58th St. Brooklyn, NY AL1042ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 052313 Agency Listings: UL Listed for Control Units for

More information

Installation Instructions Model ABHW-4S

Installation Instructions Model ABHW-4S Installation Instructions Model ABHW-4S Intelligent Audible Base for Sleeping Area with 520Hz Low Frequency Sounder Introduction Application note The Model ABHW-4S audible base from Siemens Industry, Inc.

More information

CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information

CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information OF FIRE CS24C Colored Light Strobe/orn Series igh Candela Ceiling/Wall Mount Patent Pending Description AMSECO's UL listed Colored Light Strobe CS24C series is designed to provide audible and visual signals

More information

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual Fire Safety Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual Siemens Building Technologies, Inc. Siemens Building Technologies, Ltd. 8 Fernwood Road 2 Kenview

More information

AL602ULADA. NAC Power Extender. Installation Guide (see 02 Application Guide for additional information) More than just power. TM. Rev.

AL602ULADA. NAC Power Extender. Installation Guide (see 02 Application Guide for additional information) More than just power. TM. Rev. Altronix Corp. 140 58th St. Brooklyn, NY AL602ULADA NAC Power Extender Installation Guide (see 02 Application Guide for additional information) Rev. 042209 More than just power. TM Overview: Altronix AL602ULADA

More information

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X AL1042ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 071508X Agency Listings: UL Listed for Control Units for Fire Protective Signaling Systems (UL

More information

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS ECC-50/100(E) Emergency Command Center DF-60734:A4 General Firelite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,

More information

Siemens: Cerberus Division

Siemens: Cerberus Division Ionization Detectors and Bases DI-3 Ionization Detector 309.00 DI-B3 Ionization Detector (for use with Duct Housing) 357.00 DB-3S Series 3 Low Profile Base (for DI-3) 22.00 Photoelectric Detectors and

More information

BPS NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

BPS NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev BPS-1002 NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 101413 Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864). MEA

More information

Addressable Fire Alarm Control Panel

Addressable Fire Alarm Control Panel PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT

More information

ECC-50/100C. Emergency Command Center

ECC-50/100C. Emergency Command Center ECC-50/100C Emergency Command Center Canadian DF-60815:B Emergency Communications General Fire-lite s ECC-50/100C is a multipurpose emergency voice evacuation panel for fire applications, mass notification

More information

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev Altronix Corp. 140 58th St. Brooklyn, NY AL1042ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 101413 AL1042ULADA NAC Power Extender Overview: The Altronix

More information

ECC-50/100(E) Emergency Command Center

ECC-50/100(E) Emergency Command Center ECC-50/100(E) Emergency Command Center DF-60734:A9 C-200 General Fire Lite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,

More information

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA CONVENTIONAL FIRE ALARM CONTROL UNITS MR-2300 SERIES Fire Alarm Control Units Description Secutron s MR-2300 Series fire alarm control panels consist of six and twelve zone models which are equipped with

More information

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel ACC-25/50ZST Zoned System Voice with Telephone Evacuation Control Panel General The AUDIO COMMAND CENTER 25/50 Zone System with FireFighters Telephone (ACC-25/50ZST) is a state-of-the-art Emergency Voice

More information

FIRE DETECTION CONTROL PANEL OPERATING & MAINTENANCE MANUAL

FIRE DETECTION CONTROL PANEL OPERATING & MAINTENANCE MANUAL FIRE DETECTION CONTROL PANEL OPERATING & MAINTENANCE MANUAL APPROVED An ISO 9001 Registered Company IMPORTANT SERVICE NOTICE When requesting service assistance, or to order parts for this control panel,

More information

*15cd models are Listed at 15cd and meet 75cd on axis

*15cd models are Listed at 15cd and meet 75cd on axis 273 Branchport Avenue Long Branch, NJ 07740 Thank you for using our products. (800) 631-2148 INSTALLATION INSTRUCTIONS www.wheelockinc.com MULTITONE STROBE APPLIANCES Use this product according to this

More information

AL600ULADA. NAC Power Extender. Installation Guide

AL600ULADA. NAC Power Extender. Installation Guide AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery

More information

SAFEPATH SAFEPATH. Emergency communications system

SAFEPATH SAFEPATH. Emergency communications system SAFEPATH SAFEPATH Emergency communications system ALERiTY Integrated mass notification solutions by Eaton; designed to protect, alert and inform your most critical resources your people ALERiTY /a ler

More information

Agent Release Control Panel

Agent Release Control Panel Agent Release Control Panel System Capacity Annunciators: 8 Electrical Specifications RP-2002 (FLPS-7 Power Supply): 120 VAC, 60 Hz, 3.66 amps RP-2002E (FLPS-7 Power Supply): 240 VAC, 50 Hz, 2.085 amps

More information

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description CONVENTIONAL FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped with

More information

D9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels

D9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels D9412GV2/D7412GV2 EN Approved Applications Compliance Guide Control Panels D9412GV2/D7412GV2 Approved Applications Compliance Guide Listings and Approvals Listings and Approvals Fire UL The D9412GV2 and

More information

June 10, 2002 DF C S2424

June 10, 2002 DF C S2424 GENERAL www.firelite.com The Fire Lite FIRE COMMAND 25/50X is a state-of-theart Emergency Voice Evacuation Control Panel (VECP), with significant technological enhancements that set it apart from other

More information

Innovation that Endures

Innovation that Endures Innovation that Endures Fire-Lite on our NEW Emergency Communication Alarms is the first non-proprietary brand to receive UL2572 listing System! www.firelite.com Suppression Control Panels Fire-Lite s

More information

Speakers and Speaker Strobes

Speakers and Speaker Strobes Kingfisher Company, inc. Speakers and Speaker Strobes Features: Approvals include: UL Standard 1971, UL Standard 1480, New York City (MEA), California State Fire Marshall (CSFM), Factory Mutual (FM), and

More information

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906 s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones

More information

July 14, 1999 DF C-100.

July 14, 1999 DF C-100. www.firelite.com GENERAL The Fire Lite FIRE COMMAND 25/50 is a state-of-theart, compact, stand-alone or slave Emergency Voice Evacuation Control Panel (VECP). The FIRE COMMAND 25/50 is offered in a self-contained,

More information

Table 1: dba Ratings for AMT Multitone Signal Typical Anechoic dba at 10 Feet per CAN/ULC S525-07

Table 1: dba Ratings for AMT Multitone Signal Typical Anechoic dba at 10 Feet per CAN/ULC S525-07 273 Branchport Avenue Long Branch, NJ 07740 (800) 631-2148 (USA) Thank you for using our products. (800) 397-5777 (CANADA) www.coopernotification.com GENERAL: INSTALLATION INSTRUCTIONS AMT MULTITONE APPLIANCES

More information

Intelligent Analog/Addressable Fire Alarm/Voice Integration Systems. IntelliKnight TM Series

Intelligent Analog/Addressable Fire Alarm/Voice Integration Systems. IntelliKnight TM Series Intelligent Analog/ Fire Alarm/Voice Integration Systems IntelliKnight TM Series CONVENTIONAL FIRE ALARM CONTROL PANELS SK-Conventional Series 2- to 30-Zone Fire Alarm Control Panels (FACPs) Whether your

More information

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor s Data Sheet Fire Safety & Security Products 08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor AS-MC-CW AS-MC-R AH-W AH-R Product Overview

More information

Release Control Fire Alarm Systems

Release Control Fire Alarm Systems SYSTEM ABORT PUSH AND HOLD COIL SUPERVISION MODULE (2 AMP) 2081-9046 RED INSTALLATION INSTRUCTIONS 574-437 REV YEL NAC+ MAINTAIN 1/4" SEPARATION BETWEEN POWER LIMITED (RED/) AND NONPOWER S LIMITED (YEL/)

More information

Control Panels D9412GV4/D7412GV4/D7212GV4. Approved Applications Compliance Guide

Control Panels D9412GV4/D7412GV4/D7212GV4. Approved Applications Compliance Guide Control Panels D9412GV4/D7412GV4/D7212GV4 en Approved Applications Compliance Guide GV4 Series Approved Applications Compliance Guide Listings and Approvals GV4 Listings and Approvals Fire UL The D9412GV4

More information

PFC-4064 Conventional Fire Alarm Panel

PFC-4064 Conventional Fire Alarm Panel PFC-4064 Conventional Fire Alarm Panel Installation, Operations & Programming Manual Potter Electric Signal Company, LLC St. Louis, MO Customer Service: (866) 240-1870 Technical Support: (866) 956-1211

More information

s Notification Appliances

s Notification Appliances s Notification Appliances Data Sheet Fire Safety Products AS & AH Audible Horn Strobe / Audible Horn Appliances Application: Indoor / Outdoor AS-MC-CW AS-MC-R AH-R AH-W Product Overview Fast installation

More information

GEM-X255 CONTROL PANEL/COMMUNICATOR

GEM-X255 CONTROL PANEL/COMMUNICATOR R R INSTALLATION INSTRUCTIONS HARDWIRE WIRELESS GEM-X255 CONTROL PANEL/COMMUNICATOR GEMINI SYSTEM ARMED 01/01/00 01/01/97 12:00AM ARMED STATUS NEXT/YES A 123 D E PRIOR/NO B 4 56 F AREA C 7890G COMPUTERIZED

More information

Remote NAC Power Supply D7038

Remote NAC Power Supply D7038 Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus

More information

MR-2602 Two Zone Fire Alarm Control Panel

MR-2602 Two Zone Fire Alarm Control Panel MR-2602 Two Zone Fire Alarm Control Panel Installation Manual Secutron LT-2015 Rev.3 July 2010 Table of Contents 1 Introduction 1.1 The MR-2602 Fire Alarm Control Unit... 11 1.1.1 General features...

More information

Control/Communicator 5110XM. Installation Instructions Installation Instructions Installation Instructions N8026 4/96

Control/Communicator 5110XM. Installation Instructions Installation Instructions Installation Instructions N8026 4/96 Control/Communicator 5110XM Installation Instructions Installation Instructions Installation Instructions N8026 4/96 TABLE OF CONTENTS Section 1: GENERAL DESCRIPTION... 6 Basic Hardwired...6 Remote Keypads...6

More information

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING GENERAL The VEC 25/50 is a state-of-the-art, compact, stand-alone or slave Emergency Voice Evacuation Control. The VEC 25/50 is offered in a self-contained, cost-effective design and includes a 25 Watt,

More information

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum. September 29, 1997 Firecycle III 433 a 1. PRODUCT NAME VIKING Model E-1 Manufactured 1997 Present 2. MANUFACTURED FOR THE VIKING CORPORATION 210 N Industrial Park Road Hastings, Michigan 49058, U.S.A.

More information

Potter Wall Mount Select-A-Strobe

Potter Wall Mount Select-A-Strobe 104 Kenran Industrial Dr. Potter Wall Mount Select-A-Strobe SL-1224 SERIES SELECT-A-STROBE Call for additional listings 12 VDC with 15, 35 or 60 cd setting 24 VDC with 15, 35, 60, 5, 95 or 110 6 distinct

More information

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E SpectrAlert Advance Description System Sensor SpectrAlert Advance offers a variety of devices designed for mass notification, including plain devices for non-fire applications, amber lens strobes and speaker

More information

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize advanced ideas advancedsolutions At System Sensor, Research and Development is more than a department. It s a way of life. Every day we work to design new products that utilize the most innovative technologies

More information

Fire Alarm Devices. Drexel Thrash Laborers Training Center. Supplier: Tri S Controls

Fire Alarm Devices. Drexel Thrash Laborers Training Center. Supplier: Tri S Controls Oh, Lic #26962 Drexel Thrash Laborers Training Center Fire Alarm Devices Supplier: Tri S Controls SHOP DRAWINGS Lake Erie Electric, Inc. FOR DWG. & SPEC. CONFORMITY ONLY D.M.Y 08/17/2016 By ebelba at 11:16

More information

MPC-6000 / MPC-7000 / RND-2

MPC-6000 / MPC-7000 / RND-2 MPC-6000 / MPC-7000 / RND-2 Fire Alarm System Control Unit Installation, Operation and Maintenance Manual Siemens Building Technologies, Inc. 8 Fernwood Road Florham Park, NJ 07932 Tel: (973) 593-2600

More information

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS PXL Conventional Zone Fire Alarm Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS 12 Zone System Expandable to 32 10 Amp Base Power Supply Multiple Power Supplies Available - Local or Remote 4 Notification

More information

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

Use this product according to this instruction manual. Please keep this instruction manual for future reference. 273 Branchport Avenue Thank you for using our products. Long Branch, NJ 07740 (800) 631-2148 INSTALLATION INSTRUCTIONS www.cooperwheelock.com E50 MULTI-CANDELA SPEAKER STROBES GENERAL: Use this product

More information

D7052. Installation Instructions Multiplex Dual Input Module

D7052. Installation Instructions Multiplex Dual Input Module D EN Installation Instructions Multiplex Dual Input Module D Installation Instructions Notices Notices Figure : D Features These instructions cover the installation of the D Multiplex Dual Input Module

More information

Notification Appliance Circuit Module

Notification Appliance Circuit Module Notification Appliance Circuit Module D192G en Installation guide Notification Appliance Circuit Module Notices en 3 1 Notices These instructions cover the installation of the D192G Notification Appliance

More information

SELECT-A-HORN/STROBE SERIES

SELECT-A-HORN/STROBE SERIES SELECT-A-HORN/STROBE SERIES Features Description Mircom s Select-A-Strobe/Horn Series is designed to comply with the Americans with Disability Act (ADA) and meet UL standard 1971 requirements for emergency

More information

DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM

DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SENTROL ZX400/ZX410. Security System Control. Installation

SENTROL ZX400/ZX410. Security System Control. Installation SENTROL Z400/Z410 Security System Control Installation 1 2 TABLE OF CONTENTS Table of Contents New Features... 5 Z400/Z410 Wiring Diagrams... 6 Z400/Z410 Terminal Descriptions... 8 2 in 1 Zoning... 9 Conventional

More information

SIGA-CC1 Single Input Signal Module Installation Sheet

SIGA-CC1 Single Input Signal Module Installation Sheet SIGA-CC1 Single Input Signal Module Installation Sheet Personality codes Use the personality codes described below to configure the SIGA-CC1 module. See Table 1 for listing information Table 1: Personality

More information

Fire Safety. Installation Instructions. Model ADBX-11. Audible Base INTRODUCTION. Model ADBX-11

Fire Safety. Installation Instructions. Model ADBX-11. Audible Base INTRODUCTION. Model ADBX-11 Fire Safety Installation Instructions Model ADBX11 Audible Base INTRODUCTION Model ADBX11 The SIEMENS Model ADBX11 Audible Base consists of a standard Series 11 base combined with an audible device. All

More information

SOUNDER CONTROL MODULE SCM-AS4

SOUNDER CONTROL MODULE SCM-AS4 1 of 9 INTRODUCTION DESCRIPTION The forms part of the Nittan (UK)'s SENSORTEC-ANALOGUE range of Analogue Addressable Devices. This module is designed to control a group of bells or sounders from the detection

More information

L-Series, Indoor Strobes and Horn Strobes

L-Series, Indoor Strobes and Horn Strobes Notification Appliances L-Series, Indoor Strobes and Horn Strobes Indoor Selectable-Output Strobes/Horn Strobes for Ceiling Applications General The L-Series audible visible notification products offer

More information

B Series Quick Reference Guide Intrusion Small Commercial/Retail/Banking

B Series Quick Reference Guide Intrusion Small Commercial/Retail/Banking B Series Quick Reference Guide Intrusion Small Commercial/Retail/Banking B3512/B4512/B5512 Conventional Devices D125B Dual Class B Initiating Reversing Relay Control Mobile App G100 Z-Wave Home Control

More information

The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel

The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel System Sensor 3825 Ohio Avenue St. Charles, IL 60174 1-800-SENSOR2 Fax: 630-377-6495 PDRP1001.CD The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual Document 50734 C 03/11/99 Revision:

More information