1 Miniature Thermoelectric Cooler Controller MTCC-01 user's guide 1
2 Table of Contents 1. Warranty MTCC-01-xxx overview MTCC-01-xxx specification TE cooled detector temperature stabilization general information MTCC-01-xxx operation Connectors Sample kit wiring MTCC-01-xxx physical dimensions [mm] Getting started regards complete IR detection kit Unpacking Installation & connections Switching on procedure MTCC-01-xxx other related information CE Statement of conformity Electromagnetic interference Operating temperature Storage information Safety instructions Troubleshooting
3 1. Warranty VIGO System S.A. hereby represents and warrants all Products manufactured by VIGO and sold hereunder to be free from defects in workmanship or material during a period of twelve (12) months from the date of delivery save for products for which a separate warranty is given. If any Product proves however to be defective in workmanship or material within the period herein provided VIGO System undertakes to the exclusion of any other remedy to repair or at its own option replace the defective Product or part thereof free of charge and otherwise on the same conditions as for the original Product or part without extension to original warranty time. Defective parts replaced in accordance with this clause shall be placed at the disposal of VIGO. VIGO also warrants the quality of all repair and service works performed by its employees to products sold by it. In case the repair or service works should appear inadequate or faulty and should this cause malfunction or nonfunctioning of the product to which the service was performed VIGO shall at its free option either repair or have repaired or replace the product in question. The working hours used by employees of VIGO for such repair or replacement shall be free of charge to the client. This service warranty shall be valid for a period of six (6) months from the date the service measures were completed. This warranty is however subject to following conditions: 1. A substantiated written claim as to any alleged defects shall have been received by VIGO System within thirty (30) days after the defect or fault became known or occurred, and 2. The allegedly defective Product or part shall, should VIGO so require, be sent to the works of VIGO or to such other place as VIGO may indicate in writing, freight and insurance prepaid, properly packed and labeled. This warranty does not however apply when the defect has been caused through normal wear and tear or accident; misuse or other unsuitable or unauthorized use of the Product or negligence or error in storing, maintaining or in handling the Product or any equipment thereof; wrong installation, assembly or failure to service the Product or otherwise follow VIGO's service instructions including any repairs or installation or assembly or service made by unauthorized personnel not approved by VIGO or replacements with parts not manufactured or supplied by VIGO; modifications or changes of the Product as well as any adding to it without VIGO's prior authorization; burned active element by irradiation above damage thresholds electrostatic discharges improper detector bias improper TE cooler bias (TE cooler damage or active element overheating). other factors dependent on the Customer or a third party. Notwithstanding the aforesaid VIGO System liability under this clause shall not apply to any defects arising out of materials, designs or instructions provided by the Customer. This warranty is expressly in lieu of and excludes all other conditions, warranties and liabilities, expressed or implied, whether under law, statute or otherwise, including without limitation any implied warranties of merchantability or fitness for a particular purpose and all other obligations and liabilities of VIGO or its representatives with respect to any defect or deficiency applicable to or resulting directly or indirectly from the Products supplied hereunder, which obligations and liabilities are hereby expressly canceled and waived. VIGO's liability shall under no circumstances exceed the invoice price of any Product for which a warranty claim is made, nor shall VIGO in any circumstances be liable for lost profits or other consequential loss whether direct or indirect or for special damage. RMA Request Instructions: No Product may be returned without first contacting VIGO for a Return Material Authorization ('RMA') number. Please obtain a RMA number at claim@vigo.com.pl before returning any item. When requesting a RMA number, please state your order number, the product you wish to return and the reason for return. We will only accept returns which have an RMA number. Authorized returns are to be shipped according to received instruction from VIGO in appropriate shipping box. An unauthorized return, i.e. one for which an RMA number has not been issued and authorized returns however, shipped with incorrect customs documents - will not be accepted. Please print the RMA number clearly on the return label to avoid any delay in processing. Please send package to: VIGO System S.A. 129/133 Poznanska St., PL Ozarow Mazowiecki Poland 3
4 2. MTCC-01-xxx overview The MTCC-01-xxx (Miniature Thermoelectric Cooler Controller) is the module designed for supplying the thermoelectric cooler (being a part of the cooled IR detector) and providing the temperature stabilization process. The MTCC-01-xxx is suited to work with 2- and 3- stage cooled detector (2TE, 3TE). Due to the compact size, MTCC-01-xxx is especially convenient to use in OEM applications. Features Compact size Low cost Factory configured (user should NOT change these settings) High stability and precision Adjustable temperature Low power consumption 2.1. MTCC-01-xxx specification Parameter Unit Typical value Conditions, remarks 1) Temperature stability K ± 0.01 Settling time of the set detector temperature s stage TEC, Tdet=230K 3-stage TEC, Tdet=210K Power supply voltage VDD V 2.6 to to 5.5 for 2-stage TEC for 3-stage TEC Maximum TEC output current ITEC A for 2-stage TEC for 3-stage TEC Maximum TEC output voltage Vtec V Dimensions 3.6 mm 70 x 45 x 19 Weight g 1) O Electrical TAMB = 20 C, VDD = 5 V width x depth x height 35 4
5 2.2. TE cooled detector temperature stabilization general information Every cooled detector, besides containing IR sensitive structure, is equipped with: TEC (ThermoElectric Cooler), Thermistor. Depending on the requirements, like responsivity, noise level, and therefore the final temperature, detectors fabricated by VIGO contain 2-, 3- or 4-staged TE cooler. The lowest achievable temperature depends also on ambient temperature and the heat dissipated by the detector due to the detector biasing. Considering all the factors and preparing measurements under conditions comparable with those in final application, detectors are described and the final temperature is defined. The thermistor being inside the detector package gives the feedback about the IR sensor temperature and allows the controller to perform the temperature control process. The thermistor is a component common for every type of the IR sensors, which makes the temperature measurement simple and repetitive for each detector. Having the detector parameters measured, the MTCC-01-xxx controller parameters (max current, depending on the cooler) and final temperature are set, and the system is ready to work. The MTCC-01-xxx module contains low noise and precise analog path, PID controller block, and the power stage for Peltier element driving. It also has diode indicating the actual state of the controller (getting the temperature down / ready to work). Temperature controller basing on the PID algorithm allows the system to quickly achieve the final temperature, keeping it long term stable with small fluctuations and can also adapt to varying environment conditions. The MTCC-01-xxx is a linear controller, so it doesn't introduce disturbances to the IR detection system and does not affect its performance. The MTCC-01-xxx is configured at the factory to achieve stable temperature of the detector at any ambient temperature up to 30 C (unless other value agreed at time of order). 5
6 2.3. MTCC-01-xxx operation Selecting the MTCC-01-xxx parameters MTCC-01-xxx controller was configured at factory to work with defined IR detection module. Do not change any setting, do not change controllers between modules. They are not equivalent. 6
7 LED indicators MTCC-01-xxx controller has two LED diodes indicating the state of the module. RED diode (marked as POWER) is lighted if the controller supply (VSUP) is properly connected. GREEN diode (marked as LOCK) is lighted if the detector temperature achieves the set value. After turning on the power supply the GREEN LED should be off for a maximum 300 seconds depending on the detector type Connectors The picture below shows the pin configuration of the module. Supply connector Preamplifier connector AMP 1x6 AMP 2x4 Pin Symbol Function Pin Symbol Function 1 +VDD TEC controller power supply 1 -VSUP Power supply output (-) 2 TGND TEC controller power supply 2 TH2 Thermistor input 3 +VSUP Power supply input (+) 3 Vfan / N.C. Fan supply / open 4 GND Power ground 4 -TEC TEC supply output (-) 5 Vfan / N.C. Fan supply / open 5 GND Power ground 6 -VSUP Power supply input ( ) 6 TH1 Thermistor input 7 +VSUP Power supply output (+) 8 +TEC TEC supply output (-) 7
8 2.5. Sample kit wiring The sample IR detection kit consists of: 1) MTCC-01-xxx controller, 2) IR detection module (in the picture: SIPXC) 3) AMP 2x4 AMP 2x4 cable 4) AMP 1x6 power cable 2.6. MTCC-01-xxx physical dimensions [mm] 8
9 3. Getting started regards complete IR detection kit 3.1. Unpacking Before unpacking, verify if there are no visible damages of the package. Report them to the manufacturer or the distributor Installation & connections Mount the IR module in the measurement setup, Connect all elements with cables provided in the package, Make sure that all the elements are properly connected. The TEC controller is matched in the factory with the detector delivered in the IR detector set. Do not swap controllers between IR sets Switching on procedure Do not switch on the IR module power supply until ALL elements of the IR detection kit are correctly connected with the proper cables, Do not switch on the IR detector set power supply until you have confirmed that the detector set is adequately heat sinked (SIPxC and MIPxC series only). Switch on the thermoelectric cooler controller and wait until detector operating temperature is reached and stabilized. Ready state will be indicated by the LOCK green LED light, Before starting the measurements make sure the load resistance is valid. IR detector module output should be terminated by 50Ω or 1MΩ resistance depending on the bandwidth and is given in the test data provided on the module, Do not manipulate any connectors on the active IR kit this may introduce additional noises to the system or can cause severe damages due to electrostatic discharges. 9
10 4. MTCC-01-xxx other related information 4.1. CE Statement of conformity VIGO System declares that IR detection kit is fully compliant with: EU Low Voltage Directives: 73/23/EEC, 93/68/EEC EU Electromagnetic Compatibility Directives: 89/336/EEC, 91/263/EEC, 92/31/EEC, 93/68/EEC 4.2. Electromagnetic interference To avoid the electromagnetic interferences (EMI), please do not put any electromagnetic source close to the IR module. That may cause interference to the input of the preamplifier and disturb the useful signal in the IR track 4.3. Operating temperature Detector parameters are guaranteed for the environment temperature not exceeding 35 OC Storage information To ensure reliable operation and long lifetime of detector, the following conditions should be fulfilled: Storage temperature: -10ºC + 50ºC and 10% to 90% humidity, Avoid exposing to direct sunlight and strong UV/VIS light as this may result in degradation of a detector performance, Avoid electrostatic discharges (ESD). 10
11 5. Safety instructions To ensure safe and failure-free operation of the MTCC-01-xxx controller, comply with the following precautions: Do not swap TEC controllers between IR sets match serial number. Before connecting the power supply to the mains, make sure if it is compatible with the mains voltage and frequency. Do not use the controller if the temperature and the air humidity extends the values valid for the MTCC-01-xxx controller. Use the cables supplied to connect elements of the kit, dedicated for specified device only. Never cut or shorten any cable, it may cause damage to your device. Use the cables delivered by VIGO. In case of OEM systems, make sure the the cables match the specification of the controller. Turn off the power supply before plugging / unplugging cables. Avoid static discharges. MTCC-01-xxx controller is an OEM type, so it is not equipped with a case. Provide the proper shielding and avoid touching the module while operating. MTCC-01-xxx module doesn't require forced air cooling, but keep the radiator uncovered and allow the air to flowover the module. Important Note! If you are setting up own system with your own power supply, please make sure, the voltage/current matches the values of the TEC and the IR detector. 11
12 6. Troubleshooting Typical reasons of malfunction the controller and the possible solutions are collected in the following table. Symptom SUPPLY diode is not shining LOCK diode is never turned on, or turns of after some time LOCK diode is blinking Possible reason Typical solution Controller is not connected to the supply Connect the controller and the power supply together Power supply is not connected to the mains Connect the power supply to the mains Controller or power supply is broken Contact with the distributor or the manufacturer The controller is not connected with the IR detector Properly connect the controller and the detector TEC efficiency is too small Increase the final detector temperature by reconfiguring switches or using potentiometer Environment temperature is too high Keep the environment temperature within the limits. Controller or IR detector is broken Contact with the distributor or the manufacturer IR radiation flux is too strong Reduce the IR radiation level IR detector position is unstable, or it is exposed to the vibrations Properly mount the IR detector and keep it mechanically stable Controller or IR detector is broken Contact with the distributor or the manufacturer 12
Miniature Thermoelectric Cooler Controller MTCC-01 user's guide
Miniature Thermoelectric Cooler Controller MTCC-01 user's guide 1 Table of Contents 1. Warranty... 3 2. MTCC-01 overview... 4 2.1. MTCC-01 specification... 4 2.2. TE cooled detector temperature stabilization
More informationPreamplifier Power Supply PPS-02 user's guide
Preamplifier Power Supply PPS-02 user's guide 1 Table of contents 1. Warranty... 3 2. PPS-02 overview... 4 2.1. PPS-02 parameters... 4 2.2. Coding the symbol of the power supply...4 2.3. PPS-02 physical
More informationIR detection module VPAC-1000F user's guide
IR detection module VPAC-1000F user's guide 129/133 Poznanska St., 05-850 Ozarow Mazowiecki, Poland; tel. +48 22 733 54 20; fax +48 22 733 54 26; e-mail: info@vigo.com.pl 1 Table of Contents 1. Warranty...
More informationIR detectors user's guide
IR detectors user's guide 129/133 Poznanska St., 05-850 Ozarow Mazowiecki, Poland; tel. +48 22 733 54 20; fax +48 22 733 54 26; e-mail: info@vigo.com.pl 1 Please note: the information contained in this
More informationSeries: MBC1-TC Mini Benchtop Temperature Controller
User s Guide Series: MBC1-TC Mini Benchtop Temperature Controller Imagine Instruments LLC:: 4500 Williams Drive, Ste 212-318 :: Georgetown, TX 78633 :: p. 855.574.6243 e-mail: info@imagineinstruments.com
More informationCompact Equipment Warranty Policy
006 07.15 Compact Equipment Warranty Policy 07/2015 Table of Contents Preface Page 1 Distributor s Warranty Responsibilities Page 1 Standard Warranties Page 2 Warranty Coverage Page 2 Warranty Limitations
More informationion Genesis Pump Controller
High Water Alarm Document No.: IONG_OM Page 1 of 7 Table of Contents Safety Precautions.......................... 1 General Overview.......................... 1 Installation.................................2
More informationIon Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm
Page 1 of 8 General Overview Thank you for purchasing an Ion Genesis controller. Take the time to read the instructions carefully before using this appliance. We strongly recommend that you keep this instruction
More informationOPERATION AND INSTALLATION MANUAL
OPERATION AND INSTALLATION MANUAL Manufactured & Serviced By: SunPumps, Inc. 325. Main St. Safford, AZ 85546 /M* gf& (928) 348-9652 Made in America 1.0 Introduction Thank you for selecting a SunPumps SP
More informationIon Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm
Ion Endeavor Controller Digital Level Control with Alternation Page 1 of 8 General Overview The Ion Endeavor is a pump controller that senses a water level of up to 72", has a configurable water level/pump
More informationInstallation and Operations Manual
Installation and Operations Manual H-IM-LLC February 2018 Part No. 25092501 Replaces H-IM-LLC (01/2014) Lead Lag Control System Table of Contents General Safety Information 2 Inspection 2 Warranty Statement
More informationInstallation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.
Installation Manual M-000 Setpoint Thermostat Version.04 M-000 HBX Control Systems Inc. TABLE OF CONTENTS Introduction Index Safety symbols and Warnings Index Receipt and Inspection Description Technical
More informationEQUIPMENT Operation Manual
EQUIPMENT Operation Manual Loctite SD15 Heat Controller Part Number 1667508 1 TABLE OF CONTENTS 1 Please Observe The Following... 3 1.1 Emphasized Sections... 3 1.2 For Your Safety... 3 1.3 Unpacking and
More informationVX SERIES Wireless Thermostat with Occupancy Sensor
VX SERIES Wireless Thermostat with Occupancy Sensor INSTRUCTION MANUAL Table of Contents Thermostat Installation... 7 Installing the Wireless Control Card...8 Mounting the thermostat to the wall...9 Thermostat
More informationSilicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual
Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual Read and understand this material before operating or servicing these heating tapes. Failure to understand
More informationDuct Mount. Installation Instructions
Duct Mount Installation Instructions 00809-0600-4975 Legal Notice The Flame Detector described in this document is the property of Rosemount. No part of the hardware, software, or documentation may be
More informationHorizontal Bottle Cooler Installation and Operation Manual
Speeds Up the Pace of Innovation Horizontal Bottle Cooler Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! TBC-50SD, 50SB/ TBC-95SD,
More informationOperation and Maintenance Manual for the SODRTEK ST 400 Radiant Pre-Heating System P/N
Operation and Maintenance Manual for the SODRTEK ST 400 Radiant Pre-Heating System P/N 5050-0540 TITLE PAGE General Information...3 Introduction...3 Specifications...3 Physical Parameters...3 Parts Identification...4
More informationExternal Wireless Sounder
External Wireless Sounder WL S50 Installation and Programming Instructions 2 Wireless Sounder Instructions Table of Contents Introduction... 4 Operational Functions... 4 Alarm / Tamper Indication...4 Low
More informationNotes: 1 Square = 1 Foot
Notes: 1 Square = 1 Foot Kronus 4TM Temperature, Humidity, CO2, Day and Night Controller Instruction Manual VANCOUVER, WASHINGTON U.S.A. VANCOUVER, WASHINGTON U.S.A. Warnings & Cautions Kronus 4 Kronus
More information1228s Multidrop INSTRUCTIONS. Installation and Operation of the AMC-1228s Electrochemical Sensor Module For Use With Multidrop AMC Monitors
228s Multidrop INSTRUCTIONS Installation and Operation of the AMC-228s Electrochemical Sensor Module For Use With Multidrop AMC Monitors IMPORTANT: Please read these installation and operating instructions
More informationCD6102 / CD6102 OC / CD6102-2
PreView Display CD6102 / CD6102 OC / CD6102-2 Operating Manual www.previewradar.com PATENTS Patented under one or more of the following U.S. Patents: 5345471, 5523760, 5457394, 5465094, 5512834, 5521600,
More informationReacti-Therm I and III Heating Modules
INSTRUCTIONS Reacti-Therm I and III Heating Modules TS-18822 TS-18824 Number TS-18822 TS-18824 Description Reacti-Therm I Heating Module (single block) Reacti-Therm III Heating Module (triple block) 2101.1
More informationWATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector
WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector IMPORTANT READ THIS FIRST....3 CAUTIONS... 3 AVOIDING NUISANCE ALARMS... 3 STANDARD FEATURES... 4 AVAILABLE OPTIONS... 4 PARTS DESCRIPTION... 5 FRONT PANEL
More informationLight Construction Equipment Consumer Warranty Policy
018b 01.13 Light Construction Equipment Consumer Warranty Policy 01/2013 Table of Contents Preface Page 1 Distributor s Warranty Responsibilities Page 1 Standard Warranties Page 2 Warranty Coverage Page
More informationQuick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010
Document No. 1800-60 Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831
More information(HSTAT Series) Instruction Manual
Silicone Rubber Heating Tapes with Adjustable Thermostat Control (HSTAT Series) Instruction Manual Read and understand this material before operating or servicing these heating tapes. Failure to understand
More informationAir Pump Up to 800 gallons
Air Pump Up to 800 gallons REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. PACKAGE CONTENTS ITEM #PBPAPK40W Questions, problems, missing parts? Before returning to your retailer, call our customer
More informationExternal Wireless Sounder
External Wireless Sounder Model: WL RWS401 Installation and Programming Instructions Table of Contents Introduction... 3 Operational Functions... 3 Alarm / Tamper Indication... 3 Low Battery Indication...
More informationwww.titancontrols.net Warnings & Cautions Zephyr 3 - Heating/Cooling Controller Instructions for Operation Troubleshooting Tips Controller Specifications Installation Example Warranty Information Service
More informationHotPoly Tote Tank / IBC Heaters (TTH Series)
HotPoly Tote Tank / IBC Heaters (TTH Series) Instruction Manual Read and understand this material before operating or servicing these heaters. Failure to understand how to safely operate these heaters
More informationOwner s Manual. PIR-1 IR Learner
Owner s Manual PIR-1 IR Learner PIR-1 Owner s Manual 2010-2013 Universal Remote Control, Inc. The information in this owner s manual is copyright protected. No part of this manual may be copied or reproduced
More informationAA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL
AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL Table of Contents Introduction 3 Incoming Inspection 3 General Safety & Warnings 3 Technical Specifications 4 Installation and Operation Instructions
More informationINSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM
INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM D-tect Systems 11814 South Election Road, Suite 200 Draper, UT 84020 www.dtectsystems.com 1 Introduction The mini
More informationHIGH VOLTAGE A.C. PROXIMITY DETECTOR HI-PROX
HIGH VOLTAGE A.C. PROXIMITY DETECTOR HI-PROX T275HP United States Design Patent : US D474, 705 S INSTRUCTION MANUAL INDEX PAGE Safety Rules... 01 General Description... 02 Low Voltage Testing... 03 Front
More informationSentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.
Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH AND LOW LEVEL ALARM 2.2 PUMP DOWN CONTROLLER 2.3
More informationLaser Distance Sensor Type M Analog-Output
Laser Distance Sensor Type M Analog-Output Operating Manual Version 2.3, May 2009 ELAG Elektronik AG l Stegackerstrasse 14 l CH-8409 Winterthur Contents 1. Safety 1.1 Laser safety 1.2 Electrical safety
More informationAMC-CD2. Human Occupancy Detector INSTRUCTION MANUAL. Please read these instructions completely and carefully before starting.
AMC-CD2 Human Occupancy Detector INSTRUCTION MANUAL IMPORTANT: Please read these instructions completely and carefully before starting. filename: 3138405D.doc Revised, 04/2015 Copyright, May 2002, AMC
More informationGETZ MANUFACTURING PART # CYLINDER DRYER
GETZ MANUFACTURING PART # 59339 CYLINDER DRYER 540 S. Main St., North Pekin, IL 61554 PH. (800) 553-3503 Fax (800) 473-6088 Website: www.getzmfg.com "YOUR FULL LINE EQUIPMENT MANUFACTURER" LIMITED WARRANTY
More informationMariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.
MariGlo LED 45 / 60 / 90 / 120 Inspiring Excellence in Fish Keeping! Instruction version: 01/10/2013 Important Safeguards To guard against injury, basic safety precautions should be observed, including
More informationCT2 Retro Box Installation Instruction Manual
` CT Retro Box Installation Instruction Manual November 007 CTB Inc. Warranty CT Retro Box CTB Inc. Warranty CTB Inc. warrants each new product manufactured by it to be free from defects in material or
More informationThermometer model 02059
Instruction Manual Thermometer model 02059 pm CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits: Sensor... 2 Features & Benefits: Display... 3 Setup...
More informationaquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual
aquamanta TM the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual Technical Information Model Wattage Aquarium Volume CH 025 CH 050 CH 100 CH 150 CH 200 CH 300 25W
More informationEVD-1 Installation, Operation, and Instruction Manual
EVD-1 Installation, Operation, and Instruction Manual Electronic Vibration Detector System (All specifications subject to revision.) EVD-1 Controller RTA (optional) POTTER ELECTRIC SIGNAL COMPANY, LLC
More informationBecause you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL
Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL 2 BECAUSE YOU RE NOT LIKE EVERYONE ELSE. And neither are we. Always at the forefront of our industry, our goal is
More informationesense CO2 Transmitter and Alarm
esense CO2 Transmitter and Alarm Installation & Manual SE-0010, SE-0012, SE-0013, SE-0014 Rev. 22 November 2015 2015, CO2Meter.com. All Rights Reserved. Table of Contents General... 3 Opening the Housing...
More informationXPIN -XT X-ray Detector Operation Manual
Detectors XPIN -XT X-ray Detector XPIN-XT-AB (Angle bracket sold separately) XPIN-XT-HS (Heat sink sold separately) DET-MAN-MED00014, Rev C, Page 1 Contents XPIN-XT X-ray Detector... 3 Initial Inspection...
More informationTurbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT
Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Underbar Equipment Back Bars Installation and Operation Manual Please read this manual completely
More informationAMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.
AMC-RAM-4 Refrigerant Alarm Module USER MANUAL IMPORTANT: Please read the installation and operating instructions completely and carefully before starting. Filename: 3310405B, DOC, AMC_RAM4_Manual.doc
More informationRemote Vehicle Control System
1 Remote Vehicle Control System PC 5100 TM Owner's Manual Factory Keyless Upgrade System IMPORTANT NOTE: The operation of the PowerCode as described in this manual is applicable to most vehicles. However,
More informationIntroduction... 1 System Overview... 1 System Diagram... 2
TABLE OF CONTENTS Introduction... 1 System Overview... 1 System Diagram... 2 Installation... 3 Console Mounting... 3 Monitor And Power Connections... 3 ASM II Console Main Harness... 4 Module Mounting...
More informationModels LBW-420-LEL (24 VDC powered) Ammonia Leak Detector
Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector CAUTION & SYMBOL DEFINITIONS: CAUTION: Gives detailed description of different situations to avoid or not avoid for the proper operation of the
More informationBecause you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0
Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL Manual v1.0 2 BECAUSE YOU RE NOT LIKE EVERYONE ELSE And neither are we. Always at the forefront of our industry, our
More information10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!
10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX 77041-4051 VOICE (713) 973-6905 FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN
More informationPROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL
PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. F 2018 nvent P/N 10-1008-167 87976466 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION INSTRUCTIONS...4
More informationThis instruction manual explains the use of three models listed on the left.
Semiconductor Manufacturing Gas Detector This instruction manual explains the use of three models listed on the left. Keep this Instruction Manual available for quick reference when needed. Read this Instruction
More informationOperation Manual Vortex mixer unitexer 1
Operation Manual Vortex mixer unitexer 1 CONTENTS 1. Introduction...1 2. Intended Use...1 3. Features...1 4. Standard Part Listing...1 5. Safety Precautions... 2 6. Operation... 2 7. Technical Specification...
More informationPM100/PM100E PLANTER MONITOR. Operator s Manual
PM100/PM100E PLANTER MONITOR Operator s Manual TABLE OF CONTENTS Safety Notices... 1 Introduction... 3 System Overview... 3 Installation... 5 Console Mounting... 5 Monitor and Power Connections... 5 Console
More informationEnvironmental Monitoring SmartSlot Card
Environmental Monitoring SmartSlot Card AP9612TH Installation and Quick Start Manual Contents Introduction............................. 1 Overview 1 Product inventory 1 Safety notice 2 Your inspection
More informationView the expanded manual: GEN5
View the expanded manual: http://aeotec.com/support GEN5 1 Aeotec by Aeon Labs Door/Window Sensor. The Aeotec by Aeon Labs Door/Window Sensor Gen5 provides your Z-Wave network with the intelligence required
More information3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A
Versa-Roll Roller Apparatus - Modular CLS-3857 OPERATIONS MANUAL 3800 North Mill Road Vineland, NJ 08360 USA Tel: 1-800-843-1794 Fax: 1-800-922-4361 Web: www.cglifesciences.com Rev. A Contents: General
More information6502B RF Distribution
6502B RF Distribution User Guide Revision A - March 2004 Part Number 15247-201 Table of Contents Table of Contents About this User Guide Purpose...................................................... 1
More informationEQUIPMENT Operation Manual
EQUIPMENT Operation Manual Loctite PUR-Dispense Head-30ml Syringe Part Number 1464918 1 TABLE OF CONTENTS 1. PLEASE OBSERVE THE FOLLOWING...3 1.1 EMPHASIZED SECTIONS...3 1.2 ITEMS SUPPLIED...3 ADDITIONAL
More informationMAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE
Wall Heater Fan MODEL #: 2275 This fan is a CSA approved component compatible with these Williams wall heaters only: 1076512.9 2076512.9 3076512.9 1276512 1876512 3076512 1076511.9 2076511.9 IMPORTANT
More informationOPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN
OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10-12 Ross Place Wetherill Park NSW 2164. P.O. Box 1851 Wetherill
More informationModel NT20e Installation Guide
Model NT20e Installation Guide Rev 1.4 Page 2 of 14 1. Preparing for Installation CAUTION Do not remove the NT20e from the Electro-static bag until instructed from this installation guide. The NT20e is
More information20 High velocity Air
20 High velocity Air Circulator 66878 Set up and Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com
More informationIntroduction... 1 System Overview... 1 System Diagram... 2
Introduction... 1 System Overview... 1 System Diagram... 2 Installation... 3 Mounting... 3 Monitor And Power Connections... 3 Harness Connection... 4 Monitor Connection... 5 System Configuration... 7 Powering
More informationCWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual
CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual This owner s manual provides instructions on safe installation use, and troubleshooting assistance. Please read it carefully and save it for reference
More informationPIR Sensor. User s Guide
User s Guide 2760347 PIR Sensor Thank you for purchasing your PIR Sensor from RadioShack. Please read this user s guide before setting up and using your new sensor. Attention: Observe precautions for handling
More information! "! # Please read these installation and operating instructions completely and carefully before starting.
! "! # $% Please read these installation and operating instructions completely and carefully before starting. File name:3009405d Revised,20/10/2008 Copyright, July 2004 The Armstrong Monitoring Corporation
More informationA2Z Ozone, Inc. PRODUCT MANUAL
A2Z Ozone, Inc. PRODUCT MANUAL INSTALLATION & OPERATION MANUAL CE www.a2zozone.com Rev. 02142018 CONTENTS Page Important Safety Instructions... Specifications... Installation Instructions... 3 4 5 Troubleshooting...
More informationPressurized Filter Up to 1250 gallons
Pressurized Filter Up to 1250 gallons REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. ITEM #FP1250UV Questions, problems, missing parts? Before returning to your retailer, call our customer service
More informationOPERATION & INSTALLATION MANUAL
OPERATION & INSTALLATION MANUAL Model: SIO 14 & SIO 18 Electric Tankless Hot Water Generators Table of Contents SAFETY INFORMATION... 1 INTRODUCTION... 2 Unit Operation:... 2 Unit Freezing:... 3 Maintenance:...
More informationThermometer with Probe model 00891A
Instruction Manual Thermometer with Probe model 00891A CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Setup... 4 Temperature Units... 4 Placement
More informationInstallation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.
Installation Manual 000 Version.0 EXP-000 HBX Control s Inc. Control s Inc. HBX EXP 000 Version.0 HBX EXP-000 EXPANSION MODULE INTRODUCTION The EXP-000 is designed to be integrated with the HBX CPU-000
More informationRev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts
PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION INSTRUCTIONS...4
More informationUSER S OPERATING AND INSTRUCTION MANUAL
Grand Rapids, Michigan, U.S.A. 49504-5298 USER S OPERATING AND INSTRUCTION MANUAL MODEL 1508-NLG SELF-ACTUATING TRAY LIDDER 1508S20000CV2 INDEX SAFETY INSTRUCTIONS... 1508S20002 SET UP... 1508S20003 OPERATING
More informationECA-DIN. Users Manual. Current and Voltage Alarms. March 2018
March 2018 -DIN Introduction The DIN-style Alarm Trip features a solid metal housing that stands up to the continual rigors of process control and factory automation applications. Rugged and reliable,
More informationMaxLite LED VAPOR TIGHT LINEAR FIXTURES
A cost effective LED Vapor Tight Fixture features a full length polycarbonate lens and a one-piece white glass reinforced polyester (GRP) body. Designed to meet or exceed seven to 10 foot-candles at 8
More informationES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor
Humidity Sensor Temperature/Humidity Sensor ES2-THB CSM ES2-THB_DS_E_3_2 Detect Humidity within an Accuracy of ±3% in a Compact Body. Set Provides Superior Humidity Control and Temperature/ Humidity Control.
More informationInstallation & Operation Manual
Humidity & Temperature Sensor 086 Accessories 086_D 08/12 Replaces: New Installation & Operation Manual Introduction The Humidity & Temperature Sensor 086 can be connected to select tekmar thermostats
More informationRoom Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.
Instruction Manual Room Monitor model 00276RM CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Setup... 4 Placement Guidelines... 5 Using the
More informationEQUIPMENT Operation Manual
EQUIPMENT Operation Manual DISPENSE TIME ITEM NO. 1464916 PUR CONTROLLER 30ML SYRINGE AUTO MAN HEATER 2 HEATER 1 PRESSURE REGULATOR Loctite PUR-Controller-30ml Syringe Part Number 1464916 TABLE OF CONTENTS
More informationCHARGED PLATE DETECTORS
CHARGED PLATE DETECTORS Model 205C and 205C-x10 Instruction Manual 4-09 1.0 GENERAL The Model 205C and 205C-x10 Charged Plate Detectors are used in conjunction with the ETS Model 212 Static Meter. They
More informationCLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N
CLIMAGUARD Air-to-Air Outdoor Heat Exchangers TX23, TX33, TX38, TX52 Model INSTRUCTION MANUAL Rev. H 2015 Pentair Equipment Protection P/N 10-1008-221 87976519 TABLE OF CONTENTS RECEIVING THE HEAT EXCHANGER...3
More informationNIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE
O P E R A T I N G I N S T R U C T I O N S NIR-50-325 RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 8 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales
More informationI.D.L. Heaters Thermal Products Ltd. Roll n Warm Installation Manual
I.D.L. Heaters Thermal Products Ltd. Roll n Warm Installation Manual 0 The Most Luxurious and Safe System For Underfloor Heating Table of Contents Important Instructions 2 Safety Instructions 3 Before
More informationCOMMERCIAL REFRIGERATOR INSTRUCTION MANUAL
COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL Model No.: TGM-69R FEATURE CHART ADVERTISING PANEL FLOURESCENT SWITCH COOLING FAN FLOURESCENT LAMP EVAPORATOR INNER DRAIN PAN SHELF DOOR HANDLE GLASS DOOR CONDENSER
More information1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR
1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR IMPORTANT: Please read these installation and operating instructions completely and carefully before
More informationXC Portable Air Conditioning
PORTABLE AIR CONDITIONERS XC Portable Air Conditioning XC-14A, XC-22A, XC-30A Models USER & INSTALLATION MANUAL www.xpcc.com 2013 Xtreme Power Conversion Corporation. All rights reserved. Table of Contents
More informationMODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL
MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL 95 Methodist Hill Drive Rochester, NY 14623 Phone: US +1.585.321.5800 Fax: US +1.585.321.5219 www.spectracomcorp.com Part Number 8143-5000-0050
More informationIndustrial Vacuums, Inc
Instructions/Spare Parts Manual Nilfisk Model GWD255 Drum Top Vacuum CAUTION: This Nilfisk vacuum cleaner is not to be used in explosion-hazardous areas, as serious injury could result. Under no circumstances
More informationInstruction Manual. AcuRite Atlas. Indoor Display model 06061
Instruction Manual AcuRite Atlas Indoor Display model 06061 How It Works AcuRite Atlas is an environmental monitoring station that delivers key information on current outdoor conditions in your exact location.
More informationHades 2. Digital Recycle and Lighting Timer with High Temp Shut-Off Instruction Manual. Notes: 1 Square = Foot/Feet
Notes: 1 Square = Foot/Feet Hades 2 Digital Recycle and Lighting Timer with High Temp Shut-Off Instruction Manual VANCOUVER, WASHINGTON U.S.A. VANCOUVER, WASHINGTON U.S.A. www.titancontrols.net Revision
More informationInstallation Guide
Installation Guide 502-018 TOA1 Series Sensor SUPERSEDES: October 22, 2010 EFFECTIVE: November 17, 2010 Plant ID: 001-3966 Table of Contents TOA1 Sensor................................ 2 Features..................................
More informationGASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL
GASGUARD O 2 Oxygen Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6 Operation.. 7 Start-up...
More informationGlass Door Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!
Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Glass Door Merchandiser Installation and Operation Manual Please read this manual completely
More informationEOS. Instruction Manual. 120V High Amperage Digital Humidity Controller. Part #
EOS 120V High Amperage Digital Humidity Controller Instruction Manual Part # 702603 www.titancontrols.net 120V High Amperage Digital Humidity Controller Warnings and Cautions Factory Settings Eos 120V
More informationTESTSAFE. minipat APPLIANCE TESTER USER MANUAL
TESTSAFE minipat APPLIANCE TESTER USER MANUAL TABLE OF CONTENTS SAFETY RULES 3 GENERAL DESCRIPTION 4-9 Overall Result 4 Earthing and Class I Appliances 5 Overall Result Class I Appliances and Cables 5
More information