TECHNICAL AND USER REQUIREMENTS FOR PERSONAL ALERT SAFETY SYSTEMS

Size: px
Start display at page:

Download "TECHNICAL AND USER REQUIREMENTS FOR PERSONAL ALERT SAFETY SYSTEMS"

Transcription

1 Centrum Naukowo Badawcze Ochrony PrzeciwpoŜarowej (Scientific and Research Centre for Fire Protection) Nadwiślańska 213, Józefów, Poland Telephone (+48) Fax.: (+48) TECHNICAL AND USER REQUIREMENTS FOR PERSONAL ALERT SAFETY SYSTEMS according to annex to the Regulation of the Minister of the Interior and Administration of April 27, 2007 on the list of products used for ensuring public safety or protecting health, life and property, and the principles of issuing admittance to use these products (Polish O.J. dated 2007, No. 143 position 1002) introduced by the amending regulation of July 20, 2010 (Polish O.J. dated 2010, No. 85 position 553) Issue: July 2010

2 On the basis of publications from Polish O.J. dated 2010, No. 85 position PERSONAL ALERT SAFETY SYSTEMS MARKINGS Marking: Personal alert safety systems PERFORMANCE Construction The device should not have any sharp edges so as not to injure the body or damage the clothing of the user. The device should constitute one entire unit with a power source and should be equipped with anti-explosion casing, in keeping with separate provisions on the essential requirements for devices and systems earmarked for use in areas subject to the danger of explosion. The meeting of requirements should be confirmed by an appropriate document. The manner of activating standby mode, as well as activating and deactivating the actual alarm ought to eliminate the possibility of accidentally activating or deactivating the device. Activation and deactivation of the device should be carried out manually when wearing a glove constituting part of the clothing which offers protection against type 3 radiant heat and flame and should require user s conscious action. The device should be equipped with an emergency function, conscious activation of the alarm proper and purposeful omission of the initial alarm stage. The system for attaching the device should guarantee permanent and reliable connection in at least two independent ways. Page 2 / 6

3 Marking The device should contain a rating plate with at least the following information: - the producer s name or symbol, - the type of device, - the factory number, - the year of production. Rating plates may be placed beneath the cover which shelters the source powering the device PARAMETERS System for attaching the device Necessary force for detaching the device from the element to which it is affixed cannot be less than 50 N Alarm signal intensity The device should emit a sound signal of at least 70 db when set at standby and initial alarm mode, whilst activation of the alarm proper should ensure a sound signal of at least 90 db. The operating mode when the device is fed at low voltage should result in the alarm signal sounding at a minimum of 60 db. Additionally, alarm mode light signalling is also permitted. The gauging of alarm signalling intensity should be carried out at a distance of 1 m from the device in a non-resonant field Operating algorithm At a minimum, the following operating algorithm is required for the device: - following activation of the standby mode, and leaving the device standstill, the initial alarm should start operating after 20 to 40 seconds. The duration of the initial sounding alarm should be 7 to 10 seconds. Movement of the device in initial alarm mode should cause the alarm to deactivate automatically and switch to standby mode. The supply system, without Page 3 / 6

4 replacing the source of energy, should ensure device standby operating time of at least 50 hours and at least 2 hours in alarm proper mode, - once the initial sounding alarm has finished the alarm proper should activate, - lowering of the power supply source to a level at which the device operates a maximum of 1.5 hours in standby mode, should be indicated acoustically in a manner which differs from the sounding of alarm modes. All of the remaining device functions not referred to in these requirements but declared by the manufacturer should operate in keeping with the individual service instructions Casing tightness The device should be constructed in a manner which guarantees its resistance to water at a depth of 1 m for 2 hours. Following this kind of test the device should operate normally Resistance to thermal shock The device should operate normally following exposure to thermal shock (1 hour at a temperature of - 30 ± 2 C; subsequently, after not more than 60 seconds the device should be placed in a heat chamber and exposed to a temperature of 50 ± 2 C for 1 hour) Resistance to higher temperatures The device should operate normally following one hour of air-conditioning at a temperature of 70 ± 2 C Flame resistance At alarm proper mode the device should be exposed to flames for 5 seconds. The height of the flames should be 600 to 700 mm above the burner exit nozzle. Temperature measured at a height of 250 mm above the burner nozzles should be 950 ± 50 C. During testing the device should be placed at a distance of 250 ± 10 mm from the burner exit nozzles. Placing of the burners should be in keeping with point of the PN-EN 136 standard. Page 4 / 6

5 During testing and following removal from the fire zone the device cannot become detached from the fixing system. The permitted burning time of the casing following removal from the fire zone is maximum of 2 seconds. The appearance of drops and splinters on the material from which the casing is made is not permissible. Following testing the device should operate normally Impact resistance Activation and deactivation of the device and normal functioning should be possible after the device has fallen accidentally on three occasions from a height of 1.5 m onto a hard concrete or ceramic surface. Page 5 / 6

6 SCIENTIFIC AND RESEARCH CENTRE FOR FIRE PROTECTION CNBOP CERTIFICATION DEPARTMENT YOUR PARTNER IN BUILDING THE QUALITY GENERAL INFORMATION Certification Department placed in CNBOP has a certificate of accreditation issued by Polish Centre of Accreditation No. AC 063 CNBOP is also a notified body in European Union (NB no. 1438) in the scope of: Directive 89/106/EEC Construction Products Directive 89/686/EEC Personal Protective Equipment The range of CNBOP notification covers 37 harmonized standards. CNBOP performs testing and European certification of: 1. Protective clothing for firemen 2. Fire detection and fire alarm systems EN 54-2 Control and Indicating Equipment EN 54-3 Fire alarm devices Sounders EN 54-4 Power supply equipment EN 54-5 Heat detectors - Point detectors EN 54-7 Smoke detectors. Point detectors using scattered light, transmitted light or ionization EN Flame detectors Point detectors EN Manual call points EN Smoke detectors Line detectors using an optical light beam EN Short-circuit isolators EN Input/output devices EN Aspirating smoke detectors EN Alarm transmission and fault warning routing equipment EN 14604:2005 Smoke alarm devices 3. Voice alarm systems EN Voice alarm control and indicating equipment EN Components of voice alarm systems Loudspeakers 4. Smoke and heat control systems EN Power supplies 5. Fixed firefighting systems EN Control and indicating devices EN Non-electrical automatic control and delay devices EN Manual triggering and stop devices EN Container valve assemblies and their actuators EN High and low pressure selector valves and their actuators EN Non-electrical disable devices EN Nozzles for CO2 systems EN Connectors EN Special fire detectors EN Pressure gauges and pressure switches EN Mechanical weighing devices EN Pneumatic alarm devices EN Check valves and non-return valves EN Sprinklers EN Wet alarm valve assemblies EN Dry alarm valve assemblies EN Water flow detectors EN Foam systems components EN Hose reels with semi-rigid hose EN Hose systems with lay-flat hose 6. Fire Hydrants EN Underground fire hydrants EN Pillar fire hydrants 1438 CNBOP performs testing and domestic certification of: 1. Fire alarm systems Service panels for fire brigade Remote signalling and service devices Spark extinguishing control panels Linear heat detector Multisensor detectors Detector bases Detectors in wind-shields 2. Control the discharge of heat and smoke exhaust fire Control panel Manuals buttons for smoke vent systems Line and rotary electromechanical drivers Electromagnetic and reverse flow actuator 3. Integration systems of fire protection equipment Incoming signal interface 4. Fixed gas firefighting systems (carbon dioxide, inert gases and their mixture, chlorinated hydrocarbons) 5. Fixed water mist extinguishing systems 6.Component of sprinkler and water spray systems Fire pumps Alarm valve assemblies (not covered by EN or EN ) Sprinklers ( not covered by EN ) Deluge valves Nozzles, sprayers, drenchers Pipe couplings, mechanical tees Plastic pipes for sprinkler systems Pipe hangers (pipe clamps, fixing brackets, tipping dowels) Pressure switches 7. Oxygen reduction systems

TECHNICAL AND USER REQUIREMENTS FOR FIRE-FIGHTING PRESSURE HOSES FOR FIRE-FIGHTING PUMPS

TECHNICAL AND USER REQUIREMENTS FOR FIRE-FIGHTING PRESSURE HOSES FOR FIRE-FIGHTING PUMPS Centrum Naukowo Badawcze Ochrony PrzeciwpoŜarowej (Scientific and Research Centre for Fire Protection) Nadwiślańska 213, 05-420 Józefów, Poland Telephone (+48) 22 789 11 11 Fax.: (+48) 22 769 33 45 e-mail:

More information

Schedule of Accreditation

Schedule of Accreditation Schedule of Accreditation Organisation Name Trading As INAB Reg No 6023 Contact Name Address BRE Global Assurance (Ireland) Ltd David Gall Contact Phone No +353 1 882 4344 Email Website Accreditation Standard

More information

CNBOP-PIB Standard Fire Protection

CNBOP-PIB Standard Fire Protection Centrum Naukowo Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego Państwowy Instytut Badawczy CNBOP-PIB-BA-01E:2014 Revision 1, February 2014 CNBOP-PIB Standard Fire Protection Laboratory Tests

More information

IMQ SPA scope as CertAlarm CCB and RTL. Last update: 12th June 2017

IMQ SPA scope as CertAlarm CCB and RTL. Last update: 12th June 2017 IMQ SPA scope as CertAlarm CCB and RTL Last update: 12th June 2017 Annex A1: Fire & Life Safety Alarm Systems Products / EN standards EN 54-2:1997 + AC:1999 + A1:2006 EN 54-3:2001 + A1:2002 + A2:2006 EN

More information

CNBOP-PIB STANDARDS FIRE PROTECTION. National Technical Assessments CNBOP-PIB-0036E:2017 EDITION 1 CENTRUM NAUKOWO-BADAWCZE OCHRONY PRZECIWPOŻAROWEJ

CNBOP-PIB STANDARDS FIRE PROTECTION. National Technical Assessments CNBOP-PIB-0036E:2017 EDITION 1 CENTRUM NAUKOWO-BADAWCZE OCHRONY PRZECIWPOŻAROWEJ CNBOP-PIB STANDARDS FIRE PROTECTION EDITION 1 National Technical Assessments CNBOP-PIB-0036E:2017 CENTRUM NAUKOWO-BADAWCZE OCHRONY PRZECIWPOŻAROWEJ PAŃSTWOWY INSTYTUT BADAWCZY S T A N D A R D C N B O P

More information

SUPRON 3 8 CE certificates 1 volountary certificate 12 Certificates of admittance PN-EN ISO 9001:2009

SUPRON 3 8 CE certificates 1 volountary certificate 12 Certificates of admittance PN-EN ISO 9001:2009 SUPRON 3 company has been founded in 1992. We are market leader in fire-fighting and safety equipment. Internal hydrants have been produced by us since 1995 r. We have 8 CE certificates for hydrants and

More information

LIST OF PUBLISHED STANDARDS

LIST OF PUBLISHED STANDARDS Report : 08-0-0 Page o : Of 7 LST OF PUBLSHED STDRDS umber SS umber nt pproved mendment SBS/T 0 SS 709:008/FP 5:007 Water spray fixed systems for fire protection 008-08-5 0-08-5 SS 0090:08.0 ommunity protection

More information

This document is a preview generated by EVS

This document is a preview generated by EVS EESTI STANDARD EVS-EN 54-18:2006 Fire detection and fire alarm systems - Part 18: Input/output devices Fire detection and fire alarm systems - Part 18: Input/output devices EESTI STANDARDIKESKUS EESTI

More information

Control and Indicating Equipment

Control and Indicating Equipment VdS Guidelines for Fire Detection and Fire Alarm Systems VdS 2540en Requirements and Test Methods VdS 2450en : 2018-12 (03) Publisher and publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174

More information

MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100

MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100 MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100 Installation Manual dmp-100_en 06/15 SATEL sp. z o.o. ul. Budowlanych 66

More information

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 3: Audible alarm devices

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 3: Audible alarm devices INTERNATIONAL STANDARD ISO 7240-3 First edition 2010-12-15 Fire detection and alarm systems Part 3: Audible alarm devices Systèmes de détection et d'alarme d'incendie Partie 3: Dispositifs d'alarme sonores

More information

Directories. B.1 Keyword Directory B.2 Tables B.3 Figures B.4 End Notes Fire Safety Guide / Siemens Switzerland Ltd

Directories. B.1 Keyword Directory B.2 Tables B.3 Figures B.4 End Notes Fire Safety Guide / Siemens Switzerland Ltd B Directories B.1 Keyword Directory...326 B.2 Tables...329 B.3 Figures...330 B.4 End Notes...332 325 B.1 Keyword Directory A addressing (collective) 93, 125 addressing (individual) 93 aerosol 69, 70, 95

More information

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 16: Sound system control and indicating equipment

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 16: Sound system control and indicating equipment INTERNATIONAL STANDARD ISO 7240-16 First edition 2007-07-01 Fire detection and alarm systems Part 16: Sound system control and indicating equipment Systèmes de détection et d'alarme d'incendie Partie 16:

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11149-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2014-10-02 to 2018-11-28 Holder of certificate: VdS

More information

Explosion Protection Engineering Principles

Explosion Protection Engineering Principles Handbook of Fire and Explosion Protection Engineering Principles for Oil, Gas, Chemical and Related Facilities Second edition Dennis P. Nolan ELSEVIER AMSTERDAM BOSTON HEIDELBERG LONDON NEW YORK OXFORD

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 7240-27 First edition 2009-04-01 Fire detection and alarm systems Part 27: Point-type fire detectors using a scattered-light, transmitted-light or ionization smoke sensor, an

More information

CO 2 Fire Extinguishing Systems

CO 2 Fire Extinguishing Systems Guidelines for Fire Extinguishing Systems Planning and Installation Content 0 Foreword... 10 0.1 Application of the VdS guidelines... 10 1 General... 10 1.1 Scope... 10 1.2 Aims... 11 1.3 Description...

More information

TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG U )

TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG U ) TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG0176866-U ) FIRE PROTECTION EQUIPMENTS PARTS CATALOGUE TRIMAX ASIA ENGINEERING & CONSTRUCTION No. 24, Jalan Pantai, 12000 Butterworth, Penang, Malaysia. Fax: +6

More information

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining The Laboratory is qualified to update standards identifying the test procedures. The laboratory requires/applies a flexible scope of accreditation permitted as detailed in the Annex. Updated list of activities

More information

NEBOSH International Technical Certificate in Oil and Gas Operational Safety

NEBOSH International Technical Certificate in Oil and Gas Operational Safety IOG1 - Element 4 - Fire protection and emergency response July 2012 NEBOSH International Technical Certificate in Oil and Gas Operational Safety Licence details RMS Publishing Victoria House, Lower High

More information

Water mist fire suppression systems. Minifog ProCon Low-pressure water mist system

Water mist fire suppression systems. Minifog ProCon Low-pressure water mist system Water mist fire suppression systems Minifog ProCon Minifog ProCon Low-pressure water mist system IRE PROTECTION Efficient even for non-enclosed equipment Minifog ProCon systems by Minimax use innovative

More information

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION CHAPTER 14 FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION SECTION FC 1401 GENERAL 1401.1 Scope. This chapter shall govern fire safety measures during the construction, alteration, or demolition

More information

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14 Przedsiębiorstwo Produkcyjno-Wdrożeniowe ARAJ sp. z o.o. 55-080 Kąty Wrocławskie, ul. Mireckiego 30 POLAND USER S MANUAL AIR HEATER TermEfekt Model PGA 14 Kąty Wrocławskie, 2004 Product identification

More information

Fire and Security Products and Services

Fire and Security Products and Services * www.redbooklive.com Fire and Security Products and Services Making LPCB Approval work for you Not all fire and security products and services on the market can be trusted in the event of a fire or attempted

More information

Specification for testing to be conducted at periodic surveillance of products and systems

Specification for testing to be conducted at periodic surveillance of products and systems Specification for testing to be conducted at periodic surveillance of products and systems RD_082, Issue 03 This guide describes the specification for testing to be conducted at periodic surveillance of

More information

SAL 4001 ADDRESSABLE ACCOUSTIC SIGNALLING DEVICE

SAL 4001 ADDRESSABLE ACCOUSTIC SIGNALLING DEVICE POLON 4000 INTERACTIVE FIRE DETECTION AND ALARM SYSTEM SAL 4001 ADDRESSABLE ACCOUSTIC SIGNALLING DEVICE Installation and Maintenance Manual IK E303 001GB IIIA Edition 2 IK E303 001GB The SAL 4001 addressable

More information

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

DUR 40Ex Intrinsically Safe SMOKE DETECTOR DUR 40Ex Intrinsically Safe SMOKE DETECTOR Installation and Maintenance Manual IK E317 001GB IB Issue 2 IK E317 001GB The Universal Optical Smoke Detector DUR 40Ex covered by the present manual, complies

More information

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants Branch Solution Wood based panel plants Fire protection solutions for wood based panel plants afety throughout the production process R The versatility of wood as a raw material and the fact that it is

More information

Consultant Specification AGILE Wireless Fire Detection System

Consultant Specification AGILE Wireless Fire Detection System Contents Scope of Work... 2 The EN54 Part 2 & 4 Fire System... 2 Standards... 2 Wireless Intelligent Photoelectric Smoke Detector Specification... 4 Wireless Intelligent Thermal Heat Detector Specification...

More information

CO 2 EXTINGUISHING SYSTEMS

CO 2 EXTINGUISHING SYSTEMS CO 2 EXTINGUISHING SYSTEMS CO 2 THE FIRE EXTINGUISHING CLASSIC: CLEAN, FAST AND RELIABLE TOTAL WALTHER, the acknowledged specialist in fire protection systems, has been manufacturing CO 2 extinguishing

More information

CHECKFIRE 210 Detection and Actuation System

CHECKFIRE 210 Detection and Actuation System DATA SHEET CHECKFIRE 210 Detection and Actuation System Features Supervised power, detection, release, and communication circuits Display module with LED system status indicators Adjustable mounting bracket

More information

COMITÉ EUROPÉEN DES ASSURANCES

COMITÉ EUROPÉEN DES ASSURANCES COMITÉ EUROPÉEN DES ASSURANCES SECRETARIAT GENERAL 3bis, rue de la Chaussée d'antin F 75009 Paris Tél. : +33 1 44 83 11 73 Fax : +33 1 44 83 11 85 Web : cea.assur.org DELEGATION A BRUXELLES Square de Meeûs,

More information

ENGINEERING PROJECTS (INDIA) LTD. (A Govt. of India Enterprise) Signature of Bidder 1 of 11 EPI

ENGINEERING PROJECTS (INDIA) LTD. (A Govt. of India Enterprise) Signature of Bidder 1 of 11 EPI FIRE PROTECTION 1 G.I.PIPES Supplying, installing, testing and commissioning of G.I Pipes confirming to IS 3589 Pt - I Heavy grade with painting, suitable type of supports, anchor fasteners, bolts nuts

More information

FIRE SUPPRESSION SYSTEM

FIRE SUPPRESSION SYSTEM FIRE SUPPRESSION SYSTEM An effective fire suppression systems work fundamentally in three ways; The corner stone has to be an efficient means of early warning/detection. Followed by either an Oxygen reduction

More information

This document is a preview generated by EVS

This document is a preview generated by EVS EESTI STANDARD EVS-EN 12094-2:2003 Paiksed tulekustutussüsteemid. Gaasikustutussüsteemide komponendid. Osa 2: Nõuded ja kontrollmeetodid mitte-elektrilistele automaatsetele juhtimis- ja viitega seadmetele

More information

Service Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT

Service Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT 58 Fire protection equipment requires care and maintenance at scheduled intervals to assure it will operate properly and safely when needed. Only personnel who are trained and qualified to maintain the

More information

SECTION AUXILIARY HEATER

SECTION AUXILIARY HEATER 14-301.03/ 1 2010MR12 SECTION 14-301.03 GENERAL DESCRIPTION The Thermo 300 auxiliary heating system is used in conjunction with the vehicle s heating system, in order to heat the passenger compartment

More information

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 20: Aspirating smoke detectors

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 20: Aspirating smoke detectors INTERNATIONAL STANDARD ISO 7240-20 First edition 2010-05-15 Fire detection and alarm systems Part 20: Aspirating smoke detectors Systèmes de détection et d'alarme d'incendie Partie 20: Détecteurs de fumée

More information

SAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM

SAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM SAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM COURSE ORIGINATOR Fire Detection Principles Nichola Allan DATE 23rd August 2013 Amendment 1 5th October 2013 Technical changes - Issued Amendment

More information

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS 61G15-32.001 61G15-32.002 61G15-32.003 61G15-32.004 61G15-32.005 61G15-32.006 61G15-32.007

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 7240-19 First edition 2007-08-15 Fire detection and alarm systems Part 19: Design, installation, commissioning and service of sound systems for emergency purposes Systèmes de

More information

designed for rail 5000 Series

designed for rail 5000 Series designed for rail 5000 Series 5000 Series The only complete SIL system 20 years of experience in the field. More than 15.000 systems supplied worldwide. A team devoted to rolling stock projects with specialized

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-26992-0 SOUTH AFRICAN NATIONAL STANDARD Fire detection and alarm systems for buildings System design, installation and servicing Published by SABS Standards Division 1 Dr Lategan Road Groenkloof

More information

CITY OF MADISON FIRE DEPARTMENT (MFD) FIRE PROTECTION SYSTEM PLANS

CITY OF MADISON FIRE DEPARTMENT (MFD) FIRE PROTECTION SYSTEM PLANS CITY OF MADISON FIRE DEPARTMENT (MFD) FIRE PROTECTION SYSTEM PLANS Fire Protection Systems includes the following: Alternate Fire Suppression Systems Atrium Fire Protection Systems Automatic Fire Sprinkler

More information

ADR 20N SELF CONTAINED OPTICAL SMOKE DETECTOR

ADR 20N SELF CONTAINED OPTICAL SMOKE DETECTOR ADR 20N SELF CONTAINED OPTICAL SMOKE DETECTOR Installation and Maintenance Manual IK E289 003GB Issue 1A IK-E322-001GB 2 The ADR 20N residential self contained optical smoke detector covered by this manual,

More information

This document is a preview generated by EVS

This document is a preview generated by EVS EESTI STANDARD EVS-EN 12094-1:2003 Paiksed tulekustutussüsteemid. Gaasikustutussüsteemide komponendid. Osa 1: Nõuded ja kontrollmeetodid elektrilise automaatjuhtimise ja viitega seadmete jaoks Fixed firefighting

More information

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas HVAC Guideline Specifications WHISPER-JET: SET SERIES Two Stage Positive Pressure Gas-Fired Infrared Radiant Tube Type Heater Commercial/Industrial Applications Technical Summary Input Range: 80,000/60,000

More information

Spark Extinguishing Systems

Spark Extinguishing Systems VdS Guidelines for VdS 2518en Requirements and Test Methods VdS 2518en : 2008-08 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln, Germany Phone: +49 221 77 66 0; Fax:

More information

Global Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

Global Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location: Global Property QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Plant: Date of Inspection Location: Inspected By: Reviewed By CONTROL VALVES (If Valves are Not Locked Open or Electronically Supervised

More information

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview Overview Modern combustion (or gas) turbine packages typically include an axial compressor, a combustion section and a turbine. Both compressor and turbine sections consist of one or more sets of fixed

More information

NY Fire Safety Institute Coordinator of Fire Safety & Alarm Systems F-80

NY Fire Safety Institute Coordinator of Fire Safety & Alarm Systems F-80 Established 1995 Preparing the future High Rise Building Fire Safety Directors Presents the FDNY Coordinator of Fire Safety and Alarm Systems Homeless Shelters (Premise Related) Certificate of Fitness

More information

Unit 5: Fire Safety Installations

Unit 5: Fire Safety Installations Unit 5: Fire Safety Installations 5.1 Basic Fire Science Definition of Fire: A process of combustion accompanied by a rapid release of heat and light in varying quantities. i By products of fire: Gas and

More information

In the event of a halt in operations, the economic detriment to client and own business is in addition to the significant risks of consumer supply

In the event of a halt in operations, the economic detriment to client and own business is in addition to the significant risks of consumer supply Logistics In the event of a halt in operations, the economic detriment to client and own business is in addition to the significant risks of consumer supply shortages, loss of market positioning, and possible

More information

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES SHIPPING NOTICE Maritime Authority of the Cayman Islands Head Office 3 rd Floor, Government Administration Building, 133 Elgin Avenue PO Box 2256, Grand Cayman, KY1-1107, Cayman Islands Tel: +1 345 949

More information

Tail-end valve stations

Tail-end valve stations VdS Guidelines for water extinguishing systems VdS 2100-15en Requirements and test methods VdS 2100-15en : 2011-05 (02) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,

More information

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit Operating instructions for the system user VIESMANN With constant temperature or weather-compensated control unit VITODENS 050-W 9/2014 Please keep safe. Safety instructions For your safety Please follow

More information

Chapter 7 Fire Protection

Chapter 7 Fire Protection Chapter 7 Fire Protection 7.1 Risk and Fire Protection Planning 140 7.2 Fire Detection System 142 7.3 Fire Alarm Center and Systems Engineering 143 7.4 Alarm and Evacuation 144 7.5 Fire Extinguishing Systems

More information

User manual Contractor s machinery / vehicles, tooling machines and special machines

User manual Contractor s machinery / vehicles, tooling machines and special machines Fire extinguisher system for engine compartments User manual Contractor s machinery / vehicles, tooling machines and special machines Hydro pneumatic activation Mechanical activation Electrical activation

More information

Loss Prevention Standard

Loss Prevention Standard Loss Prevention Standard LPS 1653: Issue 1.1 This Loss Prevention Standard is the property of BRE Global Ltd. and is made publicly available for information purposes only. Its use for testing, assessment,

More information

APPLICATION FOR FIRE CERTIFICATE / FIRE CLEARANCE UNDER THE MAURITIUS FIRE AND RESCUE SERVICE ACT 2013 OFFICE USE ONLY

APPLICATION FOR FIRE CERTIFICATE / FIRE CLEARANCE UNDER THE MAURITIUS FIRE AND RESCUE SERVICE ACT 2013 OFFICE USE ONLY Mauritius Fire and Rescue Service 14, Deschartres Street, Port Louis. Tel No: 2113580; Fax: 2113258 Email: mfrs_headoffice@govmu.org FSD Form 1 File No. Date received: Received by: Signature: APPLICATION

More information

Detection, and Suppression Systems

Detection, and Suppression Systems Fire Detection, Protection, ti and Suppression Systems Objectives (1 of 5) Explain why all fire fighters should have a basic understanding of fire protection systems. Describe the basic components and

More information

Unified Fire Authority - Fire Prevention Bureau

Unified Fire Authority - Fire Prevention Bureau Unified Fire Authority - Fire Prevention Bureau FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance

More information

Üntel is ready for CPR

Üntel is ready for CPR 2016 Üntel is ready for CPR Hakan Kubas Marketing Manager 01.11.2016 Construction Products Regulation What is the CPR? The Construction Products Regulation (CPR) lays down conditions for the placing or

More information

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle!

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle! Trumatic E 7 7 2 9 9 4 Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7 To be kept in the vehicle! Trumatic E 2400 (Australia) Table of contents Installation example...

More information

contents iii Drilling Tools 27 Adjustable Choke 27 Automatic Drillers 29 MWD and LWD Tools 30 How They Work 30 Uses 30

contents iii Drilling Tools 27 Adjustable Choke 27 Automatic Drillers 29 MWD and LWD Tools 30 How They Work 30 Uses 30 Figures v Foreword ix Acknowledgments xi Units of Measurement xii Introduction 1 Pipe Handling Equipment 3 Kelly Spinners 3 Maintenance 6 Spring Slips and Power Slips 7 Maintenance 9 Automatic Pipe Handlers

More information

Fire Protection Systems Operation and Maintenance 3 PDH / 3 CE Hours

Fire Protection Systems Operation and Maintenance 3 PDH / 3 CE Hours Fire Protection Systems Operation and Maintenance 3 PDH / 3 CE Hours United Facilities Criteria U. S. Department of Defense UFC 3-601-02 PDH Academy PO Box 449 Pewaukee, WI 53072 www.pdhacademy.com pdhacademy@gmail.com

More information

LaserFOCUS VLF-250 Engineering Specification

LaserFOCUS VLF-250 Engineering Specification Vision Fire & Security LaserFOCUS VLF-250 Engineering Specification May 2004 Part Number 20296 LaserFOCUS VESDA 2 VESDA LaserFOCUS Contents Scope...4 Description...4 General...4 Approvals...4 Codes, Standards

More information

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment) LISTING NUMBER afp - 2086 Commonwealth Scientific and Industrial Research Organisation, Australia Ph.: 61 (0)3 9252 6000 Fax: 61 (0)3 9252 6011 Web site: http://www.activfire.gov.au E-mail: info@activfire.gov.au

More information

RE: BASIC FIRE SAFETY PROCEDURES AND OPERATION OF FIRE EQUIPMENT

RE: BASIC FIRE SAFETY PROCEDURES AND OPERATION OF FIRE EQUIPMENT March 15, 2016 Security Staff Training Memo RE: BASIC FIRE SAFETY PROCEDURES AND OPERATION OF FIRE EQUIPMENT Dear Staff Officers: As part of your daily rounds, security officers must look out for any unsafe

More information

Methodist College Emergency Procedures

Methodist College Emergency Procedures Methodist College Emergency Procedures 2018 Tornado Watch/Warning Tornado Watch/Warning Objectives In this lesson you will learn to: Identify the difference between tornado watch and tornado warning Identify

More information

ISO INTERNATIONAL STANDARD. Fire protection Automatic sprinkler system Part 9: Requirements and test methods for water mist nozzles

ISO INTERNATIONAL STANDARD. Fire protection Automatic sprinkler system Part 9: Requirements and test methods for water mist nozzles INTERNATIONAL STANDARD ISO 6182-9 First edition 2005-11-01 Fire protection Automatic sprinkler system Part 9: Requirements and test methods for water mist nozzles Protection contre l'incendie Systèmes

More information

Australian Standard. Fire detection and alarm systems. Part 6: Carbon monoxide fire detectors using electro-chemical cells

Australian Standard. Fire detection and alarm systems. Part 6: Carbon monoxide fire detectors using electro-chemical cells AS 7240.6 2006 ISO 7240-6:2004 AS 7240.6 2006 Australian Standard Fire detection and alarm systems Part 6: Carbon monoxide fire detectors using electro-chemical cells This Australian Standard was prepared

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CEN/TS 14972 May 2008 ICS 13.220.20 English Version Fixed firefighting systems - Watermist systems - Design and installation Installations

More information

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition Copyright National Fire Protection Association 2013. All rights reserved. This copy is solely for your personal, noncommercial use in connection with participation in the NFPA Standards Development Process.

More information

XC10 combined fire detection and extinguishing control

XC10 combined fire detection and extinguishing control XC10 combined fire detection and extinguishing control Planning Tool for single-sector applications Compact panels for fire detection and extinguishing control Protecting people and assets, business processes

More information

INTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

INTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL INTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL 1- Utilize a pre-incident plan so that the industrial fire brigade member implements the responses detailed by the plan. NFPA 1081, 2012

More information

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation Operating instructions for system users VIESMANN Heating system with control unit for constant temperature operation VITODENS 100 2/2005 Please keep safe Safety instructions For your safety Please follow

More information

Scope. Warning sounders except specific requirements. Intercom Systems for Emergency Purposes. Sound Systems for Emergency Purposes

Scope. Warning sounders except specific requirements. Intercom Systems for Emergency Purposes. Sound Systems for Emergency Purposes Scope Section 6 covers all Control and Indicating Equipment including Local Alarm systems. Section 6 also covers all detectors and input/output devices, including Occupant Warning sounders except specific

More information

Microcontroller based design for Tele-sensing and extinguishing fire

Microcontroller based design for Tele-sensing and extinguishing fire Microcontroller based design for Tele-sensing and extinguishing fire Hany abdelhady Almedhegi 1, Ameen babekr abdelnaby 2, Abdelrasoul Jabar Alzubaidi 3 1 Sudan Academy of Sciences (SAS); Council of Engineering

More information

Model No: Little Devil II (inc ss)

Model No: Little Devil II (inc ss) GAS HEATER Model No: Little Devil II (inc ss) PART NO: 6926020, 6926025 (SS) OPERATION & MAINTENANCE INSTRUCTIONS LS1213 INTRODUCTION Thank you for purchasing this CLARKE Gas Heater. Before attempting

More information

Installer: (Name, address, telephone)

Installer: (Name, address, telephone) Installer: (Name, address, telephone) UNAC GUIDE No. 2 FOR THE MOTORISATION OF HINGED GATES IN ACCORDANCE WITH MACHINERY DIRECTIVE 98/37/EEC AND THE APPLICABLE PARTS OF STANDARDS EN 13241-1, EN 12453,

More information

ROLA CENTRUM NAUKOWEGO POśARNICTWA W LITEWSKIM SYSTEMIE OCHRONY PRZECIWPOśAROWEJ

ROLA CENTRUM NAUKOWEGO POśARNICTWA W LITEWSKIM SYSTEMIE OCHRONY PRZECIWPOśAROWEJ Žydrunas KUODIS Jednostka Certyfikująca Centrum Naukowego PoŜarnictwa Republiki Litewskiej ROLA CENTRUM NAUKOWEGO POśARNICTWA W LITEWSKIM SYSTEMIE OCHRONY PRZECIWPOśAROWEJ THE ROLE OF FIRE RESEARCH CENTRE

More information

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions. User Manual for model FLOWMAX-90 Condensing water heater 85,000 BTU WARNING If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal

More information

MODULE 2. Water-Based Suppression System Basics

MODULE 2. Water-Based Suppression System Basics MODULE 2 Water-Based Suppression System Basics Based on the Ohio Building Code (OBC) National Fire Protection Association (NFPA) & Ohio Fire Code (OFC) 1 WATER-BASED SUPPRESSION SYSTEM BASICS-PART ONE

More information

Wireless Keypad GKP-S8M

Wireless Keypad GKP-S8M Wireless Keypad GKP-S8M User manual Contents Congratulations on your purchase of this Honeywell wireless keypad. To make the best out of your equipment we advise you to read this manual carefully. This

More information

ANNEX. to the. COMMISSION DELEGATED REGULATION (EU) /... of XXX

ANNEX. to the. COMMISSION DELEGATED REGULATION (EU) /... of XXX EUROPEAN COMMISSION Brussels, 9.1.2018 C(2017) 9017 final ANNEX 1 ANNEX to the COMMISSION DELEGATED REGULATION (EU) /... of XXX supplementing Directive 2014/90/EU of the European Parliament and of the

More information

Installer: (Name, address, telephone number)

Installer: (Name, address, telephone number) Installer: (Name, address, telephone number) UNAC GUIDE No. 9 FOR THE INSTALLATION OF MOTORISED VERTICAL UPWARD SLIDING GATES IN ACCORDANCE WITH MACHINERY DIRECTIVE 98/37/EEC AND THE APPLICABLE PARTS OF

More information

Detailed Cleaning Instructions

Detailed Cleaning Instructions NY Thermal Inc. Tel: (06) 67-6000 Toll Free: 1-800-688-27 Fax: 1-06-432-113 Web: www.ntiboilersl.com Email: info@ntiboilers.com Style Heat Exchanger occupants or, death. This boiler must be serviced by

More information

Sprinkler System Installer Consultation Discussion Guide

Sprinkler System Installer Consultation Discussion Guide Sprinkler System Installer Consultation Discussion Guide SUBMISSIONS DUE: NOVEMBER 09, 2018 Introduction This consultation guide is sent on behalf of the Sprinkler System Installer Provincial Advisory

More information

Torch framed Installation Guide

Torch framed Installation Guide Torch framed 40010567-0602 Installation Guide 1 2 3 4 1 < < < < 5 6 7 > > > > 2 Content 1 Introduction... 1 2 Safety Instructions... 2 3 Installation requirements... 3 3.1 Rear surface construction...

More information

RAMBLER PARK FIRE SAFETY INFORMATION

RAMBLER PARK FIRE SAFETY INFORMATION RAMBLER PARK FIRE SAFETY INFORMATION Parmenter Realty Partners 7557 Rambler Rd. Dallas, Texas 75231 214-373-9561 214-373-9620 (fax) RAMBLER PARK RAMBLER PARK FIRE SAFETY INFORMATION II. Objective To provide

More information

Hot Work Policy. Department of Risk Management. 1. Purpose. 2. Authority. 3. Scope

Hot Work Policy. Department of Risk Management. 1. Purpose. 2. Authority. 3. Scope 1. Purpose The purpose of the University of Denver Hot Work policy is to protect personnel and property from a fire caused by hot work. The DU Hot Work policy defines the responsibilities and requirements

More information

ADVANCED EXTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

ADVANCED EXTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL ADVANCED EXTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL 1- Utilize a pre-incident plan so that the industrial fire brigade member implements the responses detailed by the plan. NFPA

More information

Fire Detection System: An Overview

Fire Detection System: An Overview Fire Detection System: An Overview Arief Rahman Thanura Process & Control Engineer VICO Indonesia, LLC Member of ISA Introduction Fire accidents had happened all around the world and more concern raised

More information

Part No KEMPER Filter-Master XL

Part No KEMPER Filter-Master XL Part No. 150 0492 KEMPER Filter-Master XL 1. Application and Mode of Operation.... 2 2. Safety Instructions......... 2 3. Placing into Operation...... 3 4. Operation Elements and Function... 3-4 5. Installation

More information

Propane Flame Projector Safety instructions and operating manual

Propane Flame Projector Safety instructions and operating manual Bigflame Propane Flame Projector Safety instructions and operating manual 1 Flame projector Bigflame Safety instructions Caution The directions in this manual must be followed strictly. It is imperative

More information

Carbon Dioxide Fire Suppression Systems

Carbon Dioxide Fire Suppression Systems Carbon Dioxide Fire Suppression Systems The original "clean agent," carbon dioxide suppresses fire without leaving behind water, foam or dry chemical to damage sensitive equipment. And because there is

More information

Installer: (Name, address, telephone)

Installer: (Name, address, telephone) Installer: (Name, address, telephone) UNAC GUIDE No. 4 FOR THE MOTORISATION OF SECTIONAL GARAGE DOORS IN ACCORDANCE WITH MACHINERY DIRECTIVE 98/37/EEC AND THE APPLICABLE PARTS OF STANDARDS EN 13241-1,

More information

BUSINESS PLAN CEN/TC 72 FIRE DETECTION AND FIRE ALARM SYSTEMS EXECUTIVE SUMMARY

BUSINESS PLAN CEN/TC 72 FIRE DETECTION AND FIRE ALARM SYSTEMS EXECUTIVE SUMMARY BUSINESS PLAN CEN/TC 72 FIRE DETECTION AND FIRE ALARM SYSTEMS CEN/TC 72 Business Plan Page: 1 EXECUTIVE SUMMARY Scope To prepare standards, harmonised where necessary, to meet the essential requirements

More information

AUTOMATIC FIRE SUPPRESSION SYSTEMS

AUTOMATIC FIRE SUPPRESSION SYSTEMS AUTOMATIC FIRE SUPPRESSION SYSTEMS Effective automatic fire suppression systems are essential for the fire protection of mechanical equipment and special technologies. CONTENTS RSBP FIRE PROTECTION OF

More information