1 AIS750 Series Alarm Annunciator User Manual (Ver 23 / JUNE 2014) John Street, Thornhill, tario L3T 5W6 Phone: APEX (2739) Fax: Toll Free: mail@annunciatorca Web: wwwannunciatorca (1)

2 Introduction The AIS750 Series Alarm Annunciator system is an unparallel, modular and dual operation mode Annunciator, designed to give indication of an alarm condition, or equipment status, where a high degree of reliability and fl exibility is required The Annunciator is made of universal cells being 75 x 50mm and comprising one large window, two medium (Vertically or horizontally) or four small windows These cells can be assembled in an array to provide the number of rows and columns required to suit individual panel designs These alarm windows are driven from Four-channel Logic (Alarm) Cards and each window is illuminated by plug-in LED Modules providing a maintenance free solution The fi nished window array is housed within an attractive aluminum frame which gives a modern fl ush mounting appearance and allows the annunciator to be mounted in a single cut-out The AIS750 supports two operation modes: - Stand-alone (standard) mode: In Standard Mode, the Serial communication feature is disabled and system works as a stand-alone unit No unique address needed for cards in this mode and generally, Stand-alone mode is recommended if no serial communication needed with other devices All settings will be done by DIP switches and jumpers in this mode - Serial mode: In Serial mode, each card in the system has its own unique address All settings should be done through ALCON software in this mode Selection of features is on a per channel basis with no special tools or programming knowledge required System can communicate with other Annunciators, Cotroller and devices such as a computer in this mode The AIS750 Series Alarm Annunciator is fully programmable for a whole range of different sequences and functions as listed in the ISA Publication Annunciator Sequences and Specifi cations ISA-S181/1979 (R1985) All Logic Cards are generally interchangeable within the annunciator, so stocking requirements are minimized As the system is fully fi eld-programmable, the operating specifi cation of both alarm sequence and functions can be changed during commissioning or at a later date after the equipment is installed (2)

3 Technical Specification INPUTS Isolation and Polarity: - Each input is optically isolated up to 2000VAC - All inputs are bipolar and can accept AC or DC voltages Alarm Inputs: - Wet (voltage supplied) or dry (voltage free) contacts Field Selectable for each channel individually - Normally Open (NO) or Normally Closed (NC) Field Selectable for each channel individually - Dry Contact and 24V (DC or AC) are standard inputs and other voltages are optional as bellow - Other input Voltages; 48V,125V and 250V (DC or AC) Response Time: - Standard unit: 25ms milliseconds - Made to order from 1ms to 2s OUTPUTS Supported outputs: - Light Output - Critical Audible Relay - Non-critical Audible Relay - Critical/Non-critical Buzzer - Group Relay - Common Relay - Auxiliary (Repeat) Relay (can be set to follow Input or Output) - Common Alarm Relay - First_Up Relay Relay Rating: - 1A@24VDC - 05A@ 120VAC ALARM SEQUENCES System supports all ISA-S181/1979 (R1985) sequences including: - Manual Reset (M) - Automatic Reset (A) - Automatic Reset First Out (F3A) - Automatic Reset First Out (F1A) - Manual Reset First Out (F2M-1) - Ringback (R) - No Lock In DISPLAY Confi guration: - e single large window: (H11 type): 75x50mm (WxH) - Two medium window: (H21 type): 75x25mm (WxH) (H12 type): 375x50mm (WxH) (V21 type): 50x375mm (WxH) - Four small window: (H44 type): 375x25mm (WxH) Each window is backlit by almost unlimited life time plug-in LED Modules with 120 high bright LEDs Number of LED(s) per LED module: 2 Number of LED module per Alarm Point: H11: 4 LED modules H21, H12, V21: 2 LED modules H44: 1 LED module LED Module Color: Yellow, Red, Green, White Legends: - Laser Engraved & color fi lled - Printed translucent fi lm OPERATION MODE - Stand-alone (standard) Mode - Serial Mode with serial communication SYSTEM SETUP - In Stand-alone Mode: By DIP switches - In Serial Mode: Through ALCON software SERIAL COMMUNICATION Protocol: AIS750 supports Modbus RTU-Slave, DNP3 Serial, DNP3 Ethernet and many other protocols including; Modbus TCP, BACnet MS/TP, BACnet IP, AB EtherNet IP, Allen Bradley EtherNet, AB DF1, SNMP, GE-EGD, GE-SRTP, GE-SNP, OPC, Omron Fins, Metasys N2 Open, PUSHBUTTONS Acknowledge, Reset, Test and Mute pushbuttons are supported by the system with two choices; Remote and/or Integral pushbuttons GENERAL Supply Voltage: 24VDC Nominal (20-30VDC) Supply Current Per Alarm Point: Quiescent: 5mA (at 24VDC) LEDs: H11: 24mA (at 24VDC) H21, H12, V21: 12mA (at 24VDC) H44: 6mA (at 24VDC) Relay: 10mA per relay (at 24VDC) Additional 100mA current is required for Interface Module, Pushbutton/ Buzzer Module, Common Relay and Buzzer and Serial Communication Module Environment: Operating temperature : -20 to 60ºC Storage temperature -20 to 80 C Humidity 0-95% RH, non condensing Protection: Front Panel: IP41 Enclosure: IP20 Weight: Approximately 035 kg per H11 window Connection Terminals: - Two-part removable screw type - Maximum wire size: 25 mm 2 Mounting: Panel (fl ush) Mount Visit wwwannunciatorca for updated specifi cation These sequences are Field Selectable for each Alarm Controller (for example for H21 window type, two channels have the same sequence) Multi-drop RS485 communication is available Up to 7 Annunciators can be connected together and also to another device (3)

4 AIS750 is an unparallel, modular, dual operation mode Annunciator The annunciator is made up of windows, window being 75 x 50mm (3``x 2``) The type of cards installed dependent on system specifi cation and the required options The following pages detail the system modules, individual cell types, available options and system setting System Rear overview, Modules and Connectors Logic Card Relay Module (RM) Interface Module Com Module Alarm Inputs Common Relays External Pushbuttons Com1 (RS485/RS232) 24VDC Repeat Relay Outputs (4)

5 Window/Cell Configuration AIS750 Series Annunciators The AIS750 is modular and window based designed It is manufactured from 75x50mm windows which can be assembled in an array to provide the number of rows and columns required to suit individual panel designs Each cell within the annunciator is able to contain either; - e single large window (H11 type): 75x50mm (WxH) - Two medium windows (H21 type): 75x25mm (WxH) (H12 type): 375x50mm (WxH) (V21 type): 50x375mm (WxH) - Four small windows (H44 type): 375x25mm (WxH) Each window is illuminated by maintenance free plug-in LED Modules 75mm 375mm 40mm 20mm 50mm H11 H12 H12 V21 325mm 25mm V21 65mm H44 H44 H21 H44 H44 H21 Window Addressing (applicable in Serial mode only): Window address: m+1 Window address: m+2 Window address: m+3 Window address: m+4 Window address: x Window address: n+1 Window address: n+2 Window address: n+3 Window address: n+4 Window address: m Interface and Com Module Window address: 1 Window address: 2 Window address: 3 Window address: n System rear view Calculation of overall and cut-out size is easy by using the following formulas: Overall Size Calculation of H11, H21, H12 and H44: Width (mm)= C x _ 05 Height (mm)= R x _ 05 Cutout Size Calculation of H11, H21, H12 and H44: Width (mm)= C x _ 05 Height (mm)= R x _ 05 Overall Size Calculation of V21: Width (mm)= C x _ 05 Height (mm)= R x _ 05 Cutout Size Calculation of V21: Width (mm)= C x _ 05 Height (mm)= R x _ 05 C: Number of 75x50mm Windows in one row R: Number of 75x50mm Windows in one column (5)

6 AIS750 Series Annunciators Logic Card & Repeat Relay Module Depend on window type (H11, H21, H44, H12, V21), each Logic card supports 1, 2 or 4 inputs Each logic card can be assigned to two different groups (Critical or Non-critical) Each Input can be confi gured individually to accept Dry (potential free) or Wet (powered) contacts standard system, user can select either Dry Contact or 24VDC signals Another option is Other Voltage Voltage of this option should be determined at the time of order There are two operation modes, Stand-alone (Standard) and Serial The DIP switch on Logic Card has different settings in each mode Logic Card Each 4 channel Logic Card can be supplied with an optional 4 channel Relay Module (RM) which plugs into Logic Card and provides the user with a dry contact (potential free contact) per alarm channel for use with 3rd party devices These Repeat relays can be confi gured to operate in accordance with one of the following - Input Follower: The relay changes state each time there is a change to the associated signal input contact - Output (display) Follower: The relay changes state on alarm and faithfully follows the display window Relay Module (optional) (6)

7 ON Operation Mode Setting: Switch 1 : Stand-alone Switch 1 : Serial Mode Logic Card Settings in Stand-alone Mode: AIS750 Series Annunciators J APEX Automation Solutions AIS Logic card ON Stand-alone Mode DIP Switch setting: Sequence switch 2 switch 3 switch 4 ON Manual Reset (M) Auto Reset (A) No Lock (N) Ring Back (R) First Out-1A (F1A) First Out-2M (F2M) First Out-3A (F3A) switch 5 switch 6 switch 7 switch 8 Input 1 Input 2 Input 3 Input 4 Switch : Normally Open Input Switch : Normally Close Input The non alarm state of each individual channel can be configured to allow the channel to operate from either a NO or NC contact AIS750 supports all ISA-S181/1979 (R1985) sequences These sequences are Field Selectable for each Alarm Controller (Logic Card) For example for H11 type, each individual channel and for H21 type, each two channels will be confi gured at the same time Flowcharts of all sequences are available at the end of this document Visit the bellow links for Manual Reset & Auto Reset demonstrations (7)

8 AIS750 Series Annunciators Logic Card Settings in Stand-alone Mode: ON Operation Mode Setting: Switch 1 : Stand-alone Switch 1 : Serial Mode Alarm Group & Repeat Relay Setting 1,2 Open: Alarm Group 1 (Non-critical) 1,2 Close: Alarm Group 2 (Critical) 3,4 Open: Repeat relays (input follower) 1 3 Input 1 J APEX Automation Solutions AIS Logic card ON Input 2 Input 3 Input ,4 Close: Repeat relays, Output Follower Each Input can be confi gured individually to accept Dry (potential free) or Wet (powered) Contacts standard systems, user can select either Dry Contact or 24VAC/DC signals Another option is Other Voltage The Voltage of this feature should be determined at the time of order Input Type Setting Dry Contact Input AIS supports two groups of alarms We call these two groups; Critical and Non Critical There are two output 24V(AC/DC) Input relays on the Interface Module Each relay can be assigned to any of these two groups Other Voltage Input Each 4 channel Logic Card can be supplied with an optional 4 channel Relay Module (RM) which plugs into Logic Card and provides the user with a dry contact (volt free contact) per alarm channel to be used by 3rd party devices In Stand-alone mode, these repeat relays can be confi gured by Logic Card jumper setting (as above) to operate in accordance with one of the following - Input Follower: The relay changes state each time there is a change to the associated signal input contact - Output (display) Follower: The relay changes state on alarm and faithfully follows the display window (8)

9 Logic Card Settings in Serial Mode: In Serial operation mode, each Logic Card in the system has its own unique address This unique address is set using the switches 2-8 located on DIP switch as shown below It is important that user notes the card address when removing multiple cards or replacing a card J APEX Automation Solutions AIS Logic card ON Serial Mode DIP Switch setting: ON Logic Card DIP Switch Setting in Serial mode Switch 1 : Stand-alone Mode Switch 1 : Serial Mode Switch 2-8: Address of Logic Card (window address) Logic Cards Addressing Examples Card Address SW2 SW3 SW4 SW5 SW6 SW7 SW8 ON (9)

10 Relay Module (Repeat Relays) - optional: Individual channel Repeat Relays Each 4 channel Logic Card can be supplied with an optional 4 channel Relay Module (RM) which plugs into Logic Card and provides the user with a dry contact (potential free contact) per alarm channel for use with 3rd party devices Each relay is equipped with a change-over contact and the user can select the contact state to NO or NC using a 3 way header and 2 way jumper as shown bellow These Repeat relays can be confi gured by Logic Card jumper setting (in Stand-alone mode) or in software (in Serial mode) to operate in accordance with one of the following - Input Follower: The relay changes state each time there is a change to the associated signal input contact - Output (display) Follower: The relay changes state on alarm and faithfully follows the display window Rating of each relay would be: - 1A@24VDC - 05A@ 120VAC APEX Automation Solutions Relay Module (RM) Relay 1 Relay 2 Relay 3 Relay 4 (Relay 1) Dry contact output (Relay 2) Dry contact output (Relay 3) Dry contact output (Relay 4) Dry contact output Repeat Relays Output Setting Normally Open Output (NO) Normally Close Output (NC) (10)

11 AIS750 Series Annunciators Interface & Communication Module Interface module communicates with Logic Cards and supports internal and external pushbuttons and provides common outputs such as internal buzzer, common alarm outputs such as First-up output, common Alarm Horn, etc It also manages common functions such as system confi guration (through serial port) and communication protocols There are two relays on Interface module Function of these relays can be set by jumpers allowing the relays to operate as: Audible (Alarm Horn): Activates on alarm and remain active (within a group) until the Mute or Acknowledge pushbutton has been pressed (Horn 1 / Horn2) First-up: Activates when the fi rst alarm occurs within a group Common Alarm (Group Alarms): ce channels have been assigned to groups (Critical, Non-critical), the user is able to link a group to a common relay Interface Module The AIS750 supports two operation modes; Standalone (standard) mode and Serial mode DIP switches on Interface Module has different settings in each mode Communication Module (optional) To operate in Serial mode a Communication Card (Com Module) plugs into Interface Module to support RS485 and RS232 ports These ports are selectable by jumpers AIS750 supports Modbus RTU-Slave, DNP3 Serial, DNP3 Ethernet and many other protocols including; Modbus TCP, BACnet MS/TP, BACnet IP, AB EtherNet IP, Allen Bradley EtherNet, AB DF1, SNMP, GE-EGD, GE-SRTP, GE-SNP, OPC, Omron Fins, Metasys N2 Open, (11)

12 Interface Module Settings: AIS750 Series Annunciators The AIS750 supports two operation modes; Stand-alone (standard) and Serial mode Stand-alone mode is recommended if no serial communication needed with other devices The operation mode of Interface Module should be set as bellow table Interface module provides two common relays Each relay can be set as Alarm Horn1 (Non-critical group), Alarm Horn2 (Critical group), First-up Horn and Common Alarm Horn It also manages the internal and external pushbuttons For Serial Communication, a Com Module will be connected to this module standard systems, interface module is located in the bottom left hand corner of unit when viewed from the rear APEX Automation Solutions AIS750 Interface Module ON 4 Relay 1 Relay 1 setup Relay 2 setup Relay 2 Ack Reset Mute Test External Pushbuttons Relay 1 Output Relay 2 Output Common Relays Outputs VDC Interface Module Operation Mode setting: Operation Mode switch 1 ON 4 Stand-alone Mode Serial Mode (12)

13 AIS750 Series Annunciators Interface Module Settings: Interface Module Jumper settings for both operation modes (Stand-alone and Serial Modes): There are two relays on Interface module Function of relays can be set by jumpers as showing bellow allowing the relays to operate as: - Audible (Alarm Horn) : Activates on alarm and remain active (within a group) until the Mute or Acknowledge pushbutton has been pressed (Horn 1 / Horn2) - First-up: Activates when the fi rst alarm occurs within a group - Common Alarm (Group Alarms): ce channels have been assigned to groups (Critical, Non-critical), the user is able to link a group to a common relay Each relay is equipped with a change-over contact and the user can select the contact state to NO or NC All relay settings can be done using headers and 2 way jumpers as shown bellow APEX Automation Solutions AIS750 Interface Module ON 4 Relay 1 Relay 1 function setting Relay 2 function setting Relay 2 Common Relays Output Setting Common Relays Function Setting Normally Open Output (NO) Horn 1 (Non-critical Alarm) First-up Normally Close Output (NC) Horn 2 (Critical Alarm) Common Alarm (13)

14 Interface Module Setting in Serial Mode: AIS750 Series Annunciators For operation in Serial mode, Interface module DIP switch must be set (switch1, ) For Multi-Drop connection (connecting up to 7 units), each Interface Module in the system requires a unique address therefore the fi rst unit in any given system is address 1, the second one address 2 etc, as shown bellow APEX Automation Solutions AIS750 Interface Module ON 4 Relay 1 Relay 1 function setting Relay 2 function setting Relay 2 Interface Module DIP Switch setting: Operation Mode switch 1 ON ON 4 Standard Mode Serial Mode Node Address switch 2 switch 3 switch (14)

15 Communication Module (Com Module) - optional: Com Module provides two individual ports, Com 1 and Com 2 via a 4 pin pluggable connector (Com 2 is disabled in this system) Each port can be set as RS485 or RS232 as shown below There is a Termination Jumper for RS485 This jumper should be short ONLY for END NODE (last unit in network) RS232 Setting APEX Automation Solutions Com Module Com 2 Com 1 4 Com 2 RS485 Setting Com 1 APEX Automation Solutions Com Module For serial communciation wiring, see pages 21, 22 2 wire + GND RS485 Connections 4 D- D+ SG (D2) (D1) (GND) 2 wire RS485 Connections 4 D- D+ (D2) (D1) RS232 Connections 4 RX TX GND Com 2 Com 1 Termination Jumper: Must be close just for END NODE (15)

16 Wiring Diagram Power Supply Wiring VDC power supply + - Fuse F An external FUSE is strongly recommended as shown above + - Depend on system options, every 7-10 Logic Cards (usually each row) needs one 24VDC power connection e power connection for Interface module is mandatory + - standard systems, Interface Module is located in the bottom left hand corner cell when viewed from the rear Typical wiring diagram of system power supply (16)

17 Wiring Diagram Alarm Iuput Wiring Depend on window type (H11, H21, H12, V21, H44), each Logic card supports 1, 2 or 4 inputs Each Input should be confi gured individually to accept Dry (potential free) or powered contacts Make sure all inputs have been configured properly before wiring the system, otherwise system will be damaged Please ensure there is no external links between Input terminals and power supply terminals and wires All 2 terminals are internally connected Using this terminal for common wire for inputs is permitted ONLY when using the same power source which is supplying the system Dry Contact (potential free) Inputs Powered Individual Inputs Powered Common Inputs power supply + 0 power supply + 0 power supply + 0 power supply Input 1 Input 2 Input 3 Input 4 Input 1 Input 2 Input 3 Input 4 Input 1 Input 2 Input 3 Input 4 power supply Alarm Signals Recommended wirings Alarm Signals Alarm Signals To use the same 24VDC power source which is supplying the system, ensure that there is no external links between Input terminals and power supply terminals and wires Typical diagrams of Inputs Wiring (17)

18 Wiring Diagram Alarm Output Wiring There are two relays on Interface module Function of theses relays can be set allowing the relay to operate as: - Audible: Activates on alarm and remain active (within a group) until the Mute or Acknowledge pushbutton has been pressed (Horn 1 / Horn2) - First-up: Activates when the fi rst alarm occurs - Common Alarm (Group Alarm): ce channels have been assigned to groups (Critical, Non-critical), the user is able to link a group to common relay Each relay is equipped with a change-over contact and the user can select the contact state to NO or NC Output 1 Output 2 Dry Contact (potential free) Outputs Output 1 Output 2 HORN HORN power supply Typical wiring diagram of Alarm Outputs (18) External horn or buzzer wiring

19 Wiring Diagram External (remote) Pushbuttons Wiring As an alternative, Pushbutton Module can be supplied as a remote item or the user can use conventional panel mounting momentary/normally open pushbuttons to control the Annunciator Acknowledge Reset Mute Test - + power supply +24VDC (from same power source supplying the system) :Momentary Normally Open Pushbutton External (remote) pushbutton wiring diagram (19)

20 Wiring Diagram Repeat Relays Wiring Individual channel Repeat Relays Each 4 channel Logic Card can be supplied with an optional 4 channel Relay Module (RM) to provide dry contact (potential free) contacts per alarm channel to be used with 3rd party devices Each relay is equipped with a change-over contact and the user can select the contact state to NO or NC These relays can be confi gured to follow either input (Input Follower) or output (Output Follower) output 1 output 2 output 3 output 4 Output 1 power supply Output 2 power supply Output 3 power supply Output 4 Dry Contact (potential free) Outputs output 1 output 2 output 3 output 4 power supply Powered Outputs Typical diagram of Repeat Relays Wiring (20)

21 Wiring Diagram Serial Communciation Wiring PIN RS232 DCD RXD TXD DTR GND DSR RTS CTS - RS D+ - GND - D- - - DB9 Standard Female Connector RS232 and RS485 DB9 Female Connector Pin Confi guration Serial port equvalent pin configuration for DB9 female connector Slave (Annunciator) RS485 DB9 Female Connections Slave (Annunciator) RS232 DB9 Female Connections MASTER Serial communication wiring to Master RS232 TX RX GND TX GND RX (21)

22 Multi-Drop Communication AIS750 Series Annunciators MASTER Serial communication wiring to Master MODBUS (RS485) TX RX GND D- D+ GND For Multi-Drop connection (connecting up to 7 annunciators to another device), each Interface Module in the system (each Annunciator) requires a unique address (node address), starting with 1 for the fi rst Annunciator, address 2 for second Annunciator, etc Termination Jumper (see page 15) on Communication Module must be closed for END NODE Multi-Drop Communication D+ GND D- up to 7 annunciators D+ GND D- RS485 MODBUS communciation diagram Master Node 1 (Interface address 1) Node 2 (Interface address 2) Node 3 (Interface address 3) RS485 (22)

23 Serial communication wiring to Master DNP3 (RS485) RS485 (GND) To Master RS485 (Data-) (DNP3) RS485 (Data+) Serial Communication Gateway (SCG) Ethernet To Master (DNP3) -0V +24VDC AIS750 supports Modbus RTU-Slave, DNP3 Serial, DNP3 Ethernet and many other protocols including; Modbus TCP, BACnet MS/TP, BACnet IP, AB EtherNet IP, Allen Bradley EtherNet,AB DF1, SNMP, GE-EGD, GE-SRTP, GE-SNP, OPC, Omron Fins, Metasys N2 Open, RS485 other protocols communciation diagram Master Node 1 (Interface address 1) Node 2 (Interface address 2) Node 3 (Interface address 3) SIG SIG SIG RS485 (23)

24 Modbus and DNP3 Registers List and Spec: Communication: RS485, 19200, No Parity, 2 stop bits Annunciators address (node address): 1 to 7 Modbus address same as Annunciator address Coil Address Read-Write Function DNP Data Class DNP3 Address From 4001 to 5999 Write Serial Input Signal From to Read Interface Module Data From to Read Logic Card Data Coil Address Function 4001 Acknowledge All 4002 Reset All 4003 Mute All 4004 Test All 4101 to 4210 Single Point Acknowledge 4301 to 4410 Single Point Reset 4501 to 4610 Single Point Mute 4701 to 4810 Single Point Test 4901 to 4904, 4911 to 4914,, 5991 to 5994 Single Inputg Signal Interface Module (Common) Registers (40001 and 40002): Bits Interface module data First- Up Com Alarm Crtcl Horn Alarm Horn Interface module data Logic Cards Registers and (will be repeated up to and 40222: Bits Alrm4 Alrm3 Alrm2 Alrm1 In 4 In 3 In 2 In 1 Ack4 Ack3 Ack2 Ack1 Lmp4 Lmp3 Lmp2 Lmp1 Logic card data Logic card data Flashing Type 4 (2 bits) Flashing Type 3 (2 bits) Flashing Type 2 (2 bits) Flashing Type 1 (2 bits) First -Up Com Alrm Horn Crtcl Horn Alarm Horn In 4 Crtcl Set In 3 Crtcl Set In 2 Crtcl Set In 1 Crtcl Set (24)

25 Lens Assembly Each channel is equipped with its own removable lens assembly, which contains a clear lens, a laser printed fi lm legend (if applicable), a white or coloured lens and a plastic bezel on top of them There are two options for alarm labeling; Engraving and using Translucent fi lm Bellow diagram shows the arrangement of clear lens, coloured lens and translucent fi lm Bezel Clear lens Legend fi lm White or coloured lens Display body Bezel White or coloured lens Clear lens Display body Lens assembly order using translucent film Standard lens assembly order using Engraved Lens To replace a lens or fi lm, follow the lens replacement procedure in next pages Flush mount installation Standard unit is designed for panel mount installation to allow the annunciator to be mounted in a single cut-out using the supplied mounting clamps Panel Screw Type Flush-mounting Clamp Annunciator Side View (25)

26 Window Lens Replacement Both Engraving and translucent film can be used for alarm labeling (alarm legends) Lens (or fi lm) replacement doesn t need any special tools Each window has surrounded with a plastic bezel There is a small slot at the bottom of each window (behind plastic bezel) which allows a fl at terminal screwdriver to be used to gently lever the lens forward To replace a window lens follow the following simple steps 1- Insert the screwdriver inside the slot between the windows and pop it up gently 2- Remove the plastic bezel 3- There is a small slot at the bottom of window 4- Insert the screwdriver inside the slot and lever the lens forward Visit bellow link for Lens Replacement demonstration (26) 5- Remove the lens

27 6- Place the new lens inside the frame 7- Put the screwdriver inside the slot and push the lens in 8- Secure the lens 9- Put the plastic bezel back in place 10- Push the corners of plastic bezel (27)

28 Plug-in LED Module Replacement To reduce the power consumption an to provide a maintenance free solution, Each window is illuminated by almost unlimited life time plug-in LED Modules Each LED module comes with two high bright, 120, long life LEDs Number of LED modules depends on window type Generally, each H11 (large window) has 4 LED modules so, each H21 has 2 and each H44 has 1 LED module No special tools needed to replace the LED modules To remove and install LED modules, just a general purpose pointed plier is needed Bellow picture show how to remove and install the LED modules Make sure all 8 pins of LED Module connector have been inserted properly when installing the LED Module, otherwise system could be damaged (28)

29 Alarm Sequences Manual Reset (Sequence Code M) Auto Reset (Sequence Code A) No Lock In P: Normal S: Normal V: A: Silent P: Normal S: Normal V: A: Silent P: Normal S: Normal V: A: Silent To Abnormal Acknowledge while Normal To Abnormal Return to Normal To Abnormal P: Abnormal or Normal S: Alarm V: Flashing A: Audible P: Abnormal or Normal S: Alarm V: Flashing A: Audible P: Abnormal or Normal S: Alarm V: Flashing A: Audible Acknowledge Ak ld Acknowledge while Abnormal Acknowledge while Abnormal Reset while Normal P: Abnormal or Normal S: Acknowledged V: A: Silent Return to Normal P: Abnormal S: Acknowledged V: A: Silent Return to Normal P: Abnormal or Normal S: Acknowledged V: A: Silent Manual Reset First Out (Sequence F2M-1) Auto Reset First Out (Sequence F3A) Reset while Normal Mute P: Normal S: Normal V: A: Silent P: Abnormal or Normal S: Acknowledged V: A: Silent Acknowledge Subsequent to Abnormal P: Abnormal or Normal S: Subsequent Alarm V: A: Audible First to Abnormal P: Abnormal or Normal S: First Alarm V: Flashing A: Audible Return to Normal P: Normal S: Normal V: A: Silent Acknowledge while Normal P: Abnormal or Normal S: Subsequent Alarm V: Fast Flashing A: Audible P: Abnormal S: Subsequent Acknowledged V: A: Silent Acknowledge while Abnormal Subsequent to Abnormal First out Reset First to Abnormal P: Abnormal or Normal S: First Alarm V: Intermittent Fast Flashing A: Audible Acknowledge (First-out Reset) Mute Acknowledge Acknowledge (First-out Reset) P: Abnormal or Normal S: First Silenced V: Flashing A: Silent First-out Reset while Abnormal P: Abnormal or Normal S: First Acknowledged V: Flashing A: Silent Legends: P: Process S: Sequence V: Visual A: Audible AA: Alarm Audible RA: Ringback Audible (29)

30 Alarm Sequences Ring Back (Sequence Code R) Auto Reset First Out (Sequence Code F1A) With No Subsequent Alarm State Reset P: Normal S: Ringback V: Slow Flashing return AA: Silent to normal RA: Audible Return to Normal P: Normal S: Normal V: AA: Silent RA: Silent Acknowledge while Normal Return to Abnormal P: Abnormal S: Acknowledged V: AA: Silent RA: Silent To Abnormal P: Abnormal or Normal S: Alarm V: Fast Flashing AA: Audible RA: Silent Acknowledge while Abnormal Return to Normal P: Normal S: Normal V: A: Silent Subsequent to Abnormal P: Abnormal or Normal S: Acknowledged V: A: Silent Acknowledge while Abnormal (First-out Reset) Acknowledge while Normal (First-out Reset) First to Abnormal P: Abnormal or Normal S: Alarm V: Flashing A: Audible Legends: P: Process S: Sequence V: Visual A: Audible AA: Alarm Audible RA: Ringback Audible Visit the bellow links for Manual Reset & Auto Reset demonstration Integral Push Button & Buzzer Module (option) Standard AIS750 Series Annunciator supports four remote Pushbuttons (Acknowledge, Reset, Test, Mute) and two Horns As an option, an integral Pushbutton & Buzzer Module can be fi tted in the bottom right window Order Number Model # Number of Windows in a Column (wide) Signal Voltage V0: Dry Contact V1: 24VDC/AC V2: 48VDC/AC V3: 125VDC/AC V4: 250VDC/AC V5: Others (Specify) Push Button & Buzzer Module 1: With 0: Without AIS H21 V1 1 N 1 0 Number of Windows in a Row (high) Window type Auxiliary Relay 1: With 0: Without Serial Comm 1: With 0: Without (30)

AIS750 Series Alarm Annunciator

AIS750 Series Alarm Annunciator Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

X11CA COMPUTER ANNUNCIATORS

X11CA COMPUTER ANNUNCIATORS S E R I E S XCA COMPUTER ANNUIATORS E N G I N E E R I N G C O M P A N Y The Ronan Series XCA Computer Annunciators are the latest generation of Ronan s state-of-the-art annunciators offered in window models.

More information

DRAFT 20 October 2014

DRAFT 20 October 2014 Technical data MTL process alarm equipment EPS rev 8 Programmable alarm annunciator Modular construction from 1 to 256 alarm channels Multi-redundant design so there is no single point of failure Choice

More information

Model A1700 Series Annunciator

Model A1700 Series Annunciator Seekirk Model A1700 Series Annunciator Applications: For usage in all types of process industries, electric generation, transmission and distribution, gas and water utilities. Features: The Seekirk model

More information

Series 725 Programmable Alarm Annunciator

Series 725 Programmable Alarm Annunciator Series 725 Programmable Alarm Annunciar Multi-redundant design for greater reliability Modular construction from 1 256 alarm channels Multi-redundant design so there is no single point of failure Choice

More information

SIL725 Safety Annunciator

SIL725 Safety Annunciator SIL725 Safety Annunciar Configurable SIL2 Annunciar certified IEC61508 SIRA certified at safety integrity level SIL2 IEC61508 Modular construction from 1 128 alarm channels Multi-redundant design Choice

More information

Model A2100 Series Annunciator

Model A2100 Series Annunciator Seekirk Model A2100 Series Annunciator Applications: For usage within transformers, switchgear, breakers and/or within any processing equipment or control room applications either attended or unattended

More information

System 9000TS Sequence of Events Recorder

System 9000TS Sequence of Events Recorder System 000TS Sequence of Events Recorder ms Event Recorder and combined Annunciator Modular, rack mounting design expandable to over 000 inputs ms time stamping of events across the whole system Up to,000

More information

AN-3100D Annunciator

AN-3100D Annunciator AN-3100D Annunciator FOR POWER GENERATION, TRANSMISSION & DISTRIBUTION, PETROLEUM, PETROCHEMICAL, AND OTHER PROCESS INDUSTRIES INNOVATIVE ANNUNCIATOR Continuing with the widely successful AN-3100 series

More information

4 & 8-POINT ANNUNCIATORS Instruction Manual

4 & 8-POINT ANNUNCIATORS Instruction Manual 4 & 8-POINT ANNUNCIATORS Instruction Manual 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal

More information

Model A1600 Series Annunciator

Model A1600 Series Annunciator Seekirk Model A1600 Series Annunciator Applications: For usage in all types of process industries, electric generation, transmission and distribution, gas and water utilities. Features: The Seekirk model

More information

SUB-STATION ANNUNCIATOR INSTRUCTION MANUAL

SUB-STATION ANNUNCIATOR INSTRUCTION MANUAL SUB-STATION ANNUNCIATOR INSTRUCTION MANUAL Page 1 of 76 The following methods are used in this manual to alert the user to important information:- WARNING! Warnings are provided for operator safety and

More information

725 Series Alarm Annunciator Rev 24. RTK Series 725 Annunciator

725 Series Alarm Annunciator Rev 24. RTK Series 725 Annunciator Warning The 725 System described herein operates on a logic voltage of 24VDC and as standard 24VDC is used for the field contact supply voltage. External power supplies using higher voltage AC/DC primary

More information

System 9000TS Event Recorder

System 9000TS Event Recorder Important notes The 9000TS System described herein operates on a logic voltage of VDC and as standard +VDC is used for the field contact supply voltage. External power supplies using higher voltage ac/dc

More information

Complex alarming made simple

Complex alarming made simple SEL-2523 Annunciator Panel Complex alarming made simple Superbright LEDs provide easily visible alarm indication in any lighting condition. Sequential Events Recorder (SER) data help identify the root

More information

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual PD154 & PD158 VIGILANTE II ANNUNCIATORS 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal Power

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

Standard Devices. Electronic Alarm Indication Systems. ME 3011b Standard Devices Electronic Alarm Indication Systems ME 3011b Before connecting and powering this device, please read carefully the manual, and refer to it whenever you have any doubts. This brochure is

More information

X16PDM P R O G RAMMABLE

X16PDM P R O G RAMMABLE S E R I E S XPDM P R O G RAMMABLE D I G I T A L M O N I T O R S E N G I N E E R I N G C O M P A N Y The Ronan Series XPDM Programmable Digital Monitors are the latest generation of Ronan s state-of-the-art

More information

ME 3011C / Alarm Indication / Quick Reference Guide

ME 3011C / Alarm Indication / Quick Reference Guide Tables of Contents Page Application 1 Features 1 Important Safety Information! 2 Note to this Guide 2 Further Information 2 Device Variants 2 General Functions 3 Annunciator Sequences - ISA 18.1 3 Plan

More information

Technical data MTL process alarm equipment. September 2016 INM RTK725 range rev 30. MTL RTK725 range. Alarm Annunciator

Technical data MTL process alarm equipment. September 2016 INM RTK725 range rev 30. MTL RTK725 range. Alarm Annunciator Technical data MTL process alarm equipment September 2016 INM RTK725 range rev 30 MTL RTK725 range Alarm Annunciator Safety Instructions The following methods are used in this manual to alert the user

More information

RTK 9000TS system. MTL sequence of events recorder. Technical data MTL process alarm equipment

RTK 9000TS system. MTL sequence of events recorder. Technical data MTL process alarm equipment Technical data MTL process alarm equipment EPS RTK 9000TS Rev RTK 9000TS system MTL sequence of events recorder Modular, rack mounting design expandable to over 900 inputs ms time stamping of events irrespective

More information

725B Configuration Software Manual

725B Configuration Software Manual 725B Configuration Software Manual REV DATED DESCRIPTION AUTHOR APPROVED 0 09-03-10 First Issue P.Cartmell Page 1 of 80 SECTION 1 - SOFTWARE INSTALLATION... 5 725B ConfigurationSoftware Installation...

More information

ESP TECHNOLOGIES LIMITED

ESP TECHNOLOGIES LIMITED Alarm Technology ESPAN-01 Series Annunciator System Combination type User Manual (Rev. 1) ESP TECHNOLOGIES LIMITED www.esptechno.com Content Page Introduction 2 General Description 2 Overview - Annunciator

More information

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B PRODUCT BULLETIN SB 8001B Type 8001 ALARM ANNUNCIATOR TYPE8001 FEATURES 16 or 32 alarm points per flush mount enclosure Displays are backlit with long life LEDs and engraved to suit Dimmer controls built

More information

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual Instruction manual MTL process alarm equipment October 2016 CSM 725B rev 2 MTL RTK 725B Configuration Software Manual SECTION 1 - INTRODUCTION... 5 Basic Requirements... 5 SECTION 2 - SOFTWARE INSTALLATION...

More information

On the job around the clock 24/7: Fire detection systems

On the job around the clock 24/7: Fire detection systems On the job around the clock 24/7: Fire detection systems Version 02.2010 Version: 02.2010 Product catalogue Fire detection systems This product catalogue is intended for sales purposes only. For planning,

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

USER MANUAL FOR OPERATING SYSTEM

USER MANUAL FOR OPERATING SYSTEM P2262 ALARM PANEL USER MANUAL FOR OPERATING SYSTEM 21765-07 September 1999 Associated Controls (Aust) PTY. LTD. 29 Smith Street, Hillsdale, NSW, 2036. PH (02) 9311 3255, FAX (02) 9311 3779 Page 1 of 177

More information

System 9000TS Sequence of Events Recorder

System 9000TS Sequence of Events Recorder System 9000TS Sequence of Events Recorder ms Event Recorder and combined Annunciator The RTK System 9000TS Sequence of Events Recorder leads the way in the latest technically advanced event and alarm management

More information

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET Instruction Manual Model 1582-125L 1:1 Switch February 2017, Rev. 0 CH1 HISTORY LINE HISTORY RESET AUTO MANUAL SELECT CH2 HISTORY LINE RESET MANUAL REMOTE AUTO PS1 PS2 MODEL 1582 CROSS TECHNOLOGIES INC.

More information

CLEANROOM MONITOR CR3A Network - Installation Instructions

CLEANROOM MONITOR CR3A Network - Installation Instructions CLEANROOM MONITOR CR3A Network - Installation Instructions INTRODUCTION The CR3 Series Cleanroom Monitor, was developed specifically to allow for monitoring of confined spaces with accuracy and reliability.

More information

20 Light Remote Annunciator

20 Light Remote Annunciator Light Remote Annunciator Owner s Manual Surface Mount Flush Mount 94-95- Standard Annunciator 94-, 94-95-, 95-4- 4- Annunciator w/remote Relay Panel 4-, 4-4-, 4-49-, 49-49-, 49- Time Multiplexed Annunciator

More information

IF-L/RF Protection Switch

IF-L/RF Protection Switch Instruction Manual Model 1582-1152 IF-L/RF Protection Switch August 2014, Rev. 0 CH1 HISTORY ALARM LINE HISTORY RESET AUTO MANUAL SELECT CH2 HISTORY ALARM LINE RESET MANUAL REMOTE AUTO ALARM PS1 PS2 MODEL

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

Annuciator Logic Controllers

Annuciator Logic Controllers C B0 C C5 C C6 C C7 A B A B A B A B A5 B5 A6 B6 A7 B7 A8 B8 A9 B9 5 Annuciator Logic Controllers 68 c5 c6 c7 B B B B B5 B6 B7 B8 B9 B0 B B B B B5 B6 C0 BUZZER RETURN BZ M / BZ CTROL SIGNAL LAMP DC() DC()

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with,,,, 0 and signal inputs Storage of the last state of inputs and sequence in the case

More information

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

STATUS ALARM ALARM HISTORY POWER HISTORY RESET Instruction Manual Model 1582-70L2 RF Switch June 2011, Rev. D CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL REMOTE ONLINE

More information

AO Annunciator Module

AO Annunciator Module General Specifications GS48C43Z01-00E-N AO-543-01 Annunciator Module GENERAL Figure 1 This module has two independent annunciator circuits. The circuits handle fault signals and operator actions (acknowledge,

More information

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE General Description This guide provides a summary for installing and configuring the Centaur TM Cube Slave Alarm Signalling Equipment

More information

/8 DIN Level Indicator

/8 DIN Level Indicator Data Sheet SS/_6 High visibility 5-digit LED display clear and accurate indication Analog and relay outputs as standard high, low, latch and rate alarms, plus isolated retransmission Maths functions included

More information

PTE0705 Electric Fence Monitor

PTE0705 Electric Fence Monitor PTE0705 Electric Fence Monitor The JVA logo is a registered trademark of JVA Technologies. JVA Technologies. TABLE OF CONTENTS DESCRIPTION... 2 QUICK START GUIDE... 3 FEATURES... 4 EXPLANATION OF TERMS...

More information

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign Features DATASHEET Connects to multiple sensing instruments One/Two Channel Device Bright solid state LED Alarm Display Audible Alert (internal and external) High reliability, fully dual redundant alarm

More information

NU2 Smart Power Supply (SPS) Manual

NU2 Smart Power Supply (SPS) Manual GENERAL The Smart Power Supply (SPS) is an innovative Quad Output, field programmable power supply. Each of the four outputs can provide four Amps for a total of sixteen Amps in either 12VDC or 24VDC.

More information

ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems

ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems Electronic Alarm Indication Systems ME 3011 compact Power Station Control Systems Power Distribution Control Systems Control Room Technology Automation Equipment 2 Table of Contents Contents Page System

More information

Across-the-Line SERIES MP300 Combined Manual and Automatic

Across-the-Line SERIES MP300 Combined Manual and Automatic Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps

More information

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670 Bulletin AV-670 Series 670 Hood Monitor Specifications - Installation and Operating Instructions DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Phone: 219/879-8000 Fax: 219/872-9057

More information

Soft Start Series MP700 Solid State, Reduced Voltage

Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s

More information

OPERATION / INSTALLATION

OPERATION / INSTALLATION OPERATION / INSTALLATION & PROGRAMMING MANUAL AFP-2800 LCD-80 Fire Alarm Panel Revision 1.01 November 16, 2004 NSW (Head Office) 7 Columbia Court Norwest Business Park Baulkham Hills NSW 2153 Ph: (02)

More information

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel CVENTIAL ALARM S Features: Description: The LF-CP Series Fire Alarm Control Panel is manufactured based on advanced technology while maintaining high quality during assembly. It is of solid state circuitry

More information

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D ASCO 5350 The ASCO 5350 ATS Remote Annunciator is listed under the Underwriter s Laboratories Standard UL-1008 for Automatic Transfer Switch accessories. This stand-alone device provides individual status

More information

ModBus DE-1 INSTALLATION AND USER MANUAL

ModBus DE-1 INSTALLATION AND USER MANUAL ModBus DE-1 INSTALLATION AND USER MANUAL INTESIS Software, SL Distributed by DURAN ELECTRONICA S.L Tomás Bretón 50 28045 MADRID, España duran@duranelectronica.com www.duranelectronica.com 2 2010 DURAN

More information

INTELLIGENT FIRE ALARM CONTROL PANEL

INTELLIGENT FIRE ALARM CONTROL PANEL INTELLIGENT FIRE ALARM CONTROL PANEL FX-2000 SERIES Description Mircom s FX-2000 Series Intelligent Analog Fire Alarm Control Panel is designed to provide maximum flexibility of analog system requirements

More information

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview Water Leak Detector - Four Zone with open/short-circuit detection Product overview The AX-WLDF is a four zone water leak detection module with open or short circuit sensor cable detection. The module must

More information

Control and Annunciator Panels. Compact systems of signalling and control

Control and Annunciator Panels. Compact systems of signalling and control Control and Annunciator Panels Compact systems of signalling and control 56 Control and Annunciator Panels Technical features Body material: Polycarbonate V0/UL 9 - Colour: Black degree: IP0 Not replaceable

More information

PowerLogic Branch Circuit Power Meter (BCPM)

PowerLogic Branch Circuit Power Meter (BCPM) PowerLogic Branch Circuit Power Meter (BCPM) Panel Board Monitoring System Installation Guide Branch Circuit Power Meter (BCPM) HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and

More information

Annunciator Unit SACO 16 D1. Product Guide

Annunciator Unit SACO 16 D1. Product Guide Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally open

More information

Lift Station Level Controller

Lift Station Level Controller Lift Station Level Controller Installation and Operation Manual 1 California Motor Controls, Inc. Benicia, CA Table of Contents 1. Features Product Overview... 4-6 Access Security... 7 Optional Features...

More information

Variable Frequency Drive SERIES MP800 VFD

Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controls and Accessories Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with 8, 16, 24, 32, 40 and 48 signal inputs Status retention of inputs and sequence in case

More information

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual From urgent alarms to routine messages, the PD141AFO VIGILANTE handles all types of operational messages with simplicity and economy. The VIGILANTE

More information

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1. Data Sheet Ref: 90501085 WD-CS Water leak detection cable Technical Overview The WD-CS range of cable sensors are typically used to detect water leaks usually under floors, and are used in conjunction

More information

Conventional Fire Alarm System 2014 V1.2

Conventional Fire Alarm System 2014 V1.2 Conventional Fire Alarm System 2014 V1.2 Product Overview Control Panel 2 Conventional Fire Panel GST102A 2 zone Fire panel GST104A 4 zone Fire panel GST108A 8 zone Fire panel GST116A 16 zone Fire Panel

More information

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2003-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2003-12NDS Network Fire Alarm Control Unit offers modular components to meet a

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

Annunciator unit. Application

Annunciator unit. Application Issued: April 1999 Status: April 1999 Version: B/09.11.2001 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally

More information

Universal fault annunciator for panel mounting

Universal fault annunciator for panel mounting Universal fault annunciator for panel mounting Communication over Ethernet USM - Universal-fault annunciator for panel mounting Low depth housing for panel mounting Versions with 8, 16, 32 or 48 inputs

More information

HRX Technical Manual. Version 1.2

HRX Technical Manual. Version 1.2 HRX 5000 Technical Manual Version 1.2 Contents: Specification...2 Connectors...5 RS-485 Network Connectors (J6 and J7)...5 RS-232 to Printer (J19)...6 RS-232 to PC (J8)...7 TCP/IP...8 Power (J21)...9 Fire

More information

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note Product Overview: The Pertronic F4 Remote LED Mimic / Aux Relay Module F4-RMAX is an optional extra for the Pertronic F4 conventional 4-zone fire alarm panel. This board enables the fire alarm panel to

More information

PolyGard 2-channel Gas Controller MGC-03

PolyGard 2-channel Gas Controller MGC-03 PolyGard 2-channel Gas Controller MGC-03 DESCRIPTION Gas measuring and monitoring controller based on state-ofthe-art micro-technology with integrated buzzer for continuous monitoring of the ambient air

More information

Window facia fault annunciators

Window facia fault annunciators Window facia fault annunciators WAP Window Annunciator Panel 15.08.2017 Annunciators for panel mounting with 24 signal inputs Storage of the last state of inputs and sequence in the case of power failure

More information

Technical Manual. Level Alarm Unit CARLA & WIDS

Technical Manual. Level Alarm Unit CARLA & WIDS CARLA & WIDS Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual CARLA for Tankers Cargo Tanks

More information

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer Installation and interface must be performed by a qualified controls technician. IMPORTANT: THIS MANUAL CONTAINS INFORMATION REQUIRED FOR INSTALLATION, INTERFACE AND CONFIGURATION OF THIS EQUIPMENT. READ

More information

ESSEX ENGINEERING CORPORATION

ESSEX ENGINEERING CORPORATION WATER/WASTEWATER TREATMENT CONTROL SYSTEMS AND SUBSYSTEMS 2000 SERIES CONTROL SYSTEMS: 2000 series are for surface mounting inside a control cabinet Model 2024 Electronic Alternator Duplex (two pump) pump

More information

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems Honeywell Life Safety Iberia C/Pau Vila 15-19; 08911 Badalona Barcelona T. 902 03 05 45; Internacional:+34932424236 www.honeywelllifesafety.es infohlsiberia@honeywell.com ibox Modbus Server Gateway for

More information

ACTIVE INFRARED BARRIER

ACTIVE INFRARED BARRIER Although PROTECH provides high security indoor intrusion sensors for the military and government markets, our specialty is outdoor protection. Since we first introduced our PIRAMID outdoor dual technology

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors

More information

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528] Installation- & Operation manual [Dok. id: mi-303gb_180528] Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction and control output MF-PFA ver 3.x NOTE! Read through the entire manual

More information

Networkable Fan Coil Controller Specification and Installation Instructions

Networkable Fan Coil Controller Specification and Installation Instructions Controller Models EFCB10T-OE1 (24Vac / 0 relays) EFCB12T-OE1 (240Vac / 0 relays) EFCB10TU4-OE1 (24Vac / 4 relays) EFCB12TU2-OE1 (240Vac / 2 relays) EFCB12TU4-OE1 (240Vac / 4 relays) TFL Series Thermostat

More information

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

ZIOU/230 - MAINS IO INSTRUCTION MANUAL Description ZIOU/230 - MAINS IO INSTRUCTION MANUAL The Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third party equipment with the Fire Alarm Control panel

More information

Metasys Integrator Airflow Application

Metasys Integrator Airflow Application Metasys Connectivity Technical Manual 69. Metasys Integrator Section Application Note Issue Date 0998 APPLICATION NOTE Metasys Integrator Airflow Application lntroduction Page Application Details * Component

More information

FX Intelligent Analog Fire Alarm Control Panel. Installation and Operation Manual

FX Intelligent Analog Fire Alarm Control Panel. Installation and Operation Manual Advanced Life Safety Solutions Advanced Life Safety Solutions FX-2000 Intelligent Analog Fire Alarm Control Panel Canada 25 Interchange Way Vaughan, ON L4K 5W3 Tel: 905-660-4655 Fax: 905-660-4113 U.S.A.

More information

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2003-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron's MMX-2003-12NDS is a powerful intelligent networkable fire alarm solution designed

More information

Alarm Systems. Digital Alarm Annunciator. ME 3011b Instruction Manual SERIAL PRODUCTS. Manual ME3011b_E_r07 at 1/68

Alarm Systems. Digital Alarm Annunciator. ME 3011b Instruction Manual SERIAL PRODUCTS. Manual ME3011b_E_r07 at 1/68 Alarm Systems SERIAL PRODUCTS Digital Alarm Annunciator ME 3011b Instruction Manual Manual ME3011b_E_r07 at 1/68 1 Information and Technical Data Introduction 4 Warranty 4 Installation 5 Operation Principles

More information

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1 NGC-40 Bridge Overview Raychem-AR-H58862-NGC40BridgeOV-EN-1805 nvent.com 1 Table of Contents 1. NGC-40 Overview... 9 1.1 Example NGC-40 System... 10 2. Legal stuff... 11 3. Protocols... 12 3.1 Data es...

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

MODEL DESCRIPTION PAGE

MODEL DESCRIPTION PAGE LEAK DETECTION To protect expensive electronics from costly water damage, Veris Industries offers complete leak detection systems. Monitor either a single location or a large area with our selection of

More information

MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL

MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL 5CIM2-0413 W30-AC0056 MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL Multi-zone Hydronic Chiller Interface Module SECTION 1: INTRODUCTION Unit description... 5 Location... 5 Handling... 5

More information

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System SYSTEM MANUAL FT1-SB Single Zone Fire Alarm System DOCUMENT HISTORY Issue Date Description Written By Checked By Draft 0 2/9/2008 Original Document. A. Shenouda C. Orr Issue 1 4/11/2011 Update drawing

More information

User manual. KNXgal. version

User manual. KNXgal. version User manual version 1.3 gal Management alarm control panels Galaxy from bus powered from bus Communication indication on and with Galaxy control panel DIN rail mount (1 modul) Adjustable address on with

More information

ACCURATE ELECTRONICS INC

ACCURATE ELECTRONICS INC ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A

More information

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

D A R A - 4. Data Aire Relay Auto-Changeover

D A R A - 4. Data Aire Relay Auto-Changeover D A R A - 4 Data Aire Relay Auto-Changeover WARNING: If adding the DARA-4 panel to existing units that did not include a DARA-4 panel when originally purchased it will be necessary to add a relay or relays.

More information

Application, Installation, Operation & Maintenance Manual

Application, Installation, Operation & Maintenance Manual APPROVED BY:JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL Application, Installation, Operation & Maintenance Manual PAGE 1 of 43 CONTENTS 1. INTRODUCTION... 3 2. GENERAL DESCRIPTION...

More information

STATUS ALARM HISTORY ALARM RESET

STATUS ALARM HISTORY ALARM RESET Instruction Manual Model 1582-42L Data Switch February 1999, Rev 0 CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 ONLINE SWITCH RESET MAN

More information

P2267 NETWORK INTERFACE

P2267 NETWORK INTERFACE P2267 NETWORK INTERFACE USER MANUAL FOR OPERATING SYSTEMS: 22031-03 23636-01 October 2009 Associated Controls (Australia) Pty. Limited 2-4 Norfolk Road Greenacre, NSW, 2190. PH +61 2 9642 4922, FAX +61

More information

Instruction Manual Model L2 RF Switch

Instruction Manual Model L2 RF Switch Instruction Manual Model 1582-22L2 RF Switch November 2015, Rev. A CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL REMOTE ONLINE

More information