4TEMPERATURE CONTROLLER
|
|
- Leona Conley
- 5 years ago
- Views:
Transcription
1 Universal Input Output and High Accuracy 0.5 class 250ms TEMPERATURE ONTROLLER RAMP function PID Auto-tuning Universal input /, Reverse/Direct action selectable Remote/Local input selectable Model and suffix code () L SUFFIX ODE DESRIPTION MX ONTROL OUTPUT O P T I O N 1 Retransmission output 2 Heater reak Alarm(HA) 3 Remote input F Option is not valid in MX-F. In current output(), lamp signal of OUT does not flash. M S V N N P N MX2/3/// Normal PID Auto-tuning Relay contact urrent(~20ma D) SSR drive pulse voltage(0/12v D) Voltage(1~5V D) None Refer to ODE None HA function(t separately) None Refer to ODE ODE 1 D 0~10mV 2 D 0~100mV 3 D 0~1V D 0~5V 5 D 0~10V 6 D 1~5V D 0~20mA 8 D ~20mA 68
2 R TEMPERATURE ONTROLLER Functional Description MX-F Auto tuning(at) Remote input(rem) ontrol output(out) Alarm1(AL-1) Mode(SET) key Setting digit shift key AT REM OUT AL-1 AL-2 H-LA MAN PV SV MX Process-value(PV) Set-Value(SV) ontrol loop break alarm(la)/ Heater break alarm(ha) Alarm2(AL-2) Set-Value increment key Set-Value decrement key TEMPERATURE ONTROLLER Input and Range Signal Input Temperature range Signal Input Temperature range K -50~132 (-50.0~. ) -50~2500 (-50.0~.) PR(R) 0~160 32~3200 J -50~1100 (-50.0~. ) -50~2000 (-50.0~.) PR() 0~160 32~3200 E -1~50 (-1.~50.0 ) -1~100 (-1.~.) PR(S) 0~160 32~3200 T Pt 100Ω (DIN) Pt 100Ω (JIS) -1~00 (-1.~00.0 ) -1~6 (-1.~6.0 ) -1~6 (-1.~6.0 ) -1.~50 (-1.~50.0) -1~1200 (-1.~.) -1~1200 (-1.~.) 1~5V ~20mA 0~5V 0~20mA -1~3200 (1 Mode) -1~ (0.1 Mode) -1~3200 (1 Mode) -1~ (0.1 Mode) ** autions for input selection 1) When you select input mode, you must shift jump switch inside of P to ORRET position first. 2) Afterwards select each input mode by key operation. Input T../Voltage urrent Switch position T PT R 6
3 T. MAIN TEMPERATURE ONTROLLER L MX-F MX-F TEMPERATURE ONTROLLER Appearance External dimension Input Accuracy 6X6mm(1/ DIN), mounting depth:100mm 11 Kinds of input (See input range) 2X2mm, mounting depth:100mm [Setting accuracy] T/: Within±(0.3% of SV 1 digit) or ±2 (Whichever is larger) R.S: ± 1 digit R.T.D: Within±(0.3% of SV 1 digit) or ± 0.8 (Whichever is larger) [Display accuracy] Same as setting accuracy. Power supply ontrol action ontrol output Alarm output Ambient temperature Net weight 100 to 20V A (ommon to 50/60Hz) (Excluding power supply voltage variation) PID (Auto-tuning function), ON/OFF, P.PI.PD Relay contact: A 250V 3A (Resistive load) 1(NO/N) contact SSR driving:12v D (onstant voltage pulse) [load resistance more than 800Ω] urrent: -20mA D [load resistance less than 600Ω] Voltage: 0-10V D [load resistance less than 1kΩ ] Deviation or process setting Relay contact output: A 250V 0.5A (AL-2), 3A (AL-1) 0 ~ 50 (32 ~ 122 ) Ambient humidity:35 ~ 85% RH Approx 35g Approx 300g onnection 10 OM AL-2 20 LA/HA T TRANSMIT REM mAD A T VA 50/60Hz 12VA 13 H 12-20mA D 12VD L 11 OM AL 2 LA/ HA A TRANSMIT 20mAD URRENT VOLTAGE T REM H 1 L VA 50/60Hz 12VA AL 1 20mAD 12VD 0
4 MX2-F MX3-F MX-F 8 6mm(1/8 DIN), mounting depth : 100mm 6 8mm(Horizontal), mounting depth : 100mm 8 8mm(1/16 DIN) 11 Kinds of input (See input range) Setting accuracy T/ :Within±(0.3% of SV1 digit) or±2 (Whichever is larger) R.S :± 1 digit R.T.D :Within±(0.3% of SV1 digit) or±0.8 (Whichever is larger) Display accuracy Same as setting accuracy TEMPERATURE ONTROLLER 100 to 20V A(ommon to 50/60Hz)(Excluding power supply voltage variation) PID (Auto-tuning function), ON/OFF, P.PI.PD Relay contact:a 250V 3A(Resistive load) 1(NO/N) contact SSR driving :12V D(onstant voltage pulse) load resistance more than 800Ω urrent :-20mA D load resistance less than 600Ω Voltage :0-10V D load resistance less than 1 KΩ Deviation or process setting Relay contact output:a A (AL-2), 3A (AL-1) 0~50 (32~122 ) Ambient humidity : 35~85% RH Deviation or process setting Relay contact output:a 250V 3A (Resistive load) Approx 310g Approx 310g Approx 235g.T REM OM 10 AL 2 LA/HA T. 1 A TRANSMIT 20mA D AL 1 MAIN URRENT VOLTAGE VA 50/60Hz 12VA 13 H 12 L URRENT SOLIDSTATE VA 50/60Hz 12VA URRENT SOLIDSTATE TRANSMIT AL-1 H L -20mA/D MAIN URRENT VOLTATE T. A.T REM OM AL-2 LA/HA A 8 10 URRENT SOLIDSTATE T VA 50/60Hz 12VA ALM 3 8 3A 250VA MAIN A 250VA T. 1
5 Setting of constants in display Signal on PV display Temp. range Name Description Setting range Initial set Temperature range in ramp -1~3200 (-1.~.) - Ramp Ramp(Rate) time setting 0~50 minutes - TEMPERATURE ONTROLLER * * * Proportional band Anti-reset windup Integral time Derivative time Set when proportional control is performed. Prevents overshoot and/or undershoot caused by integral action effect. Eliminates offset occurring in proportional control. Integral action turns OFF with this action set to O. Prevents ripples by predicting output change thereby improving control stability. Derivative action turns OFF with this action set to O. 1 to span ( ) 0.1~. ( ) 0~100 ( ) 0 to 3600 sec. 0 to 3600 sec. 20 ( ) 100 ( ) 20 sec. 60 sec. Hysteresis (in ON/OFF action) Displays hysteresis Set-Value for main output. 0.1~ ( ) Proportioning cycle Displays manipulated output cycle(sec.). 1 to 100 sec. (0.1 to sec.) Relay contact output : 20 sec. Voltage pulse output : 2sec. *Automatically set by Auto-tuning Alarm mode None Deviation high alarm Deviation low alarm Low alarm hold function of high/low alarm High alarm hold function of high/low alarm Hold function of high/low alarm Hold function of high alarm Process high alarm Hold function of low alarm Hold function of process high alarm and alarm Process low alarm High and low alarm Hold function of process low alarm 2
6 Operation Manual Normal mode Power supply (Power ON) (Input type) (PV) (SV) Display in Ramp function (Temp. range) Note In case of urrent and Voltage output, PID Auto-tuning does not operate by Autotuning key. Initial values of P.I and D are Programmed and you may use the unit in ordinary applications. If you are not satisfied with given values, you can change values of I and D slightly in normal mode by manual adjustment. TEMPERATURE ONTROLLER Temp. high limit Temp. low limit Output limit range:0~100% Manual output set (Select in SL- 3 mode to display this mode) range:0~100% Display in ON/OFF mode Display in HA function only Remote function mode(select in SL-3 mode to display this mode) Set 1 for operation SYSTEM SET P,A,I,D,: No display in ON/OFF mode Operates only in :1000 position. When flickers, Press to stop. Press and key simultaneously for 3 sec. to enter 3
7 Function set mode (System mode) (Alarm mode) (HA mode) (Retransmission output mode) TEMPERATURE ONTROLLER Note : Press and key simultaneously for 3 sec. and return to initial PV/SV mode in every step. Press key for 3 sec. in and return to.
8 : Input mode : Dead band of AL-1 initial value : 1 : Output terminal of AL-1 0: Indicator 1: ontroller 0: ON/OFF 1: PID 0: Direct control action for cooling 1: Reverse control action for heating MX -F Normal type 0: 1: 0: 0.1 resolution 1: 1 resolution No function key (Do not modify) 0: urrent output 1: Relay or Voltage, Pulse 0: None 1: AL-1 output AL-1 terminal(initial value) 2: AL-1 output AL-2 terminal 3: AL-1 output LA/HA terminal : Alarm-2 (Refer to alarm mode) initial value: Hold function of low alarm : Dead band of AL-2 initial value : 1.0 : Output terminal of AL-2 0: None 1: AL-2 output AL-1 terminal(initial value) 2: AL-2 output AL-2 terminal 3: AL-2 output LA/HA terminal : LA/HA function (None) (LA) (25A HA)(50A HA) TEMPERATURE ONTROLLER : Dead band of HA(A) 0: Remote input function 1: No remote input function 0: Manual output function 1: No manual output function No function key (Do not modify) 0: Ramp function 1: No ramp function : Output terminal of LA/HA 0: None 1: LA/HA output AL-1 terminal 2: LA/HA output AL-2 terminal 3: LA/HA output LA/HA terminal : Retransmission display : Input shift value range: within free scale range : Decimal point selection range : 0 ~ 3 ( in PV mode) : Span of free scale range: -1~3200-1/1 (-1~) -1/10 : Zero of free scale range: -1~3200-1/1 (-1~) -1/10 : Alarm-1 (Refer to alarm mode) initial value : Deviation high alarm (None) (PV) (SV) : Span of retransmission output range : 0~05 initial value :3500 (Do not modify) : Zero of retransmission output range : 0~05 initial value :500 (Do not modify) : Remote input calibration (Do not modify) 5
9 TEMPERATURE ONTROLLER Ramp function Ramp rate can be adjusted. (0~50 minutes) Set RAMP RATE T(urrent Transformer) Time Model T-25 Model T-50 PID Auto-Tuning (Valid in Relay and SSR output only) Press the key and key at the same time. Then, AT indication lamp flashes to start the Auto-tuning function. If Auto-tuning function ends, the AT indication lamp stops flashing automatically. When checking the auto-tuned value, press the key and conform in turn. When you want Auto-tuning function to be suspended, press the key and key simultaneously, then the AT indication lamp stops flashing to release Auto-tuning function. In this case P.I.D and ARW values are not changed (Maintain the value before the Auto-tuning starts). When you want to change the SV(set-value) during Autotuning, suspend it and perform PID control using the values before Auto-tuning starts ontrol loop break alarm(la) LA function starts to measure time from the moment that the PID omputed Value (Output ON time/cycle) become 0% or 100%, and detects the amount of Process Value change at each LA setting time, and determines by the amount of change whether LA is to be ON or OFF. When the status at a 100% PID computed value continues beyond the LA setting time, the LA turns ON if the measured-value(pv) does not rise by 2 ( ) or more. (In direct action, the above alarm turns ON if the measured-value does not fall by 2 ( ) or more. When the status at 0% PID computed value continues beyond the LA setting time, the LA turns ON if the measured-value(pv) does not fall by 2 ( ) or more. Remote input Set-value of controller can be set or changed from outside of the controller by direct voltage/current signal. ut the external signal should be input continuously. (Auto-tuning function is not operated while the external signal is set) Heater break alarm(ha) Set-value of HA to be set about 85% to input of T but the set-value should be less in case that the ratio of voltage variation is high. If several heaters are connected in parallel, the alarm may be turned ON even though one circuit is broken. In such a case, set the value of HA to be slightly high. No HA operates at O setting, but HA operates at 25.0 or 50.0 setting. 6
Safety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock.
Temperature Controller KXN Series INSTRUCTION MANUAL Thank you for purchasing HANYOUNG NUX CO,.Ltd. Product. Please check whether the prouduct you purchased is the exactly same as you ordered. Before using
More informationF4 Process Controller Installation and Operation Guide
F4 Process Controller Installation and Operation Guide 1.Introduction 1.1.Highlight Features Space saving, only 55mm panel depth required Higher sampling rate (1mS) results in better control performance
More informationSA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail
Temperature Controller General Description The is a socket mounting type temperature controller and is available for mounting inside the panel or by easily mounting on DI rail. The has features such as
More informationTemperature Controllers
Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65
More informationVERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER
1 VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1. INTRODUCTION This manual contains information for the installation and operation and tuning of our Vertex VT10 series self-tuning
More informationSA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting
Temperature Controller General Description The is a high performance 3 nd DI controller that has been specifically designed for applications where panel space is critical. Though small in size, this controller
More informationMICRO CONTROLLER S Z SERIES
Instruction Manual MICRO CONTROLLER S Z SERIES TYPE: PYW 4 5 7 9 Fuji Electric Co.,Ltd. INP-TN1PYWf-E INTRODUCTION You are now the owner of Fuji's digital Temperature Controller. Before using, be sure
More informationINSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A
INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A Preface Thank you for the purchase of our Microcomputer based Temperature Indicating Controllers JCD-13A or
More informationCommunications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)
TEMPERATURE CONTROLLER DIN-sized (96 x 96-mm) Temperature Controller Featuring Advanced PID Control and Heater Burnout Detection Advanced PID control with two degrees of freedom to improve stability and
More informationMicro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e
C C1 C2 AL1 AL2 AL3 Micro-controller X Model: PXR4/5/9 PXR SEL Operation Manual ECNO:46e Table of Contents Part Names and Functions... 6 Operations... 7 2-1 Parameter list... 7 2-2 Basic operations...
More informationTEMPERATURE CONTROL MODULE MODEL R3-TC2
INSTRUCTION MANUAL R3-TC2 TEMPERATURE CONTROL MODULE MODEL R3-TC2 CONTENTS BEFORE USE... 2 POINTS OF CAUTION... 2 COMPONENT IDENTIFICATION... 2 INSTALLATION... 2 EXTERNAL DIMENSIONS unit: mm (inch)...
More information02/11/2015
MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS
More informationI/A Series 716C 1/16 DIN Temperature Controller
Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of
More informationCommunications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03
Digital Controller A 96 x 96-mm (DIN) Digital Process Controller Optimum PID control with feed-forward control circuitry. High accuracy (+0.3% FS +1 digit max.). Replaceable Output Units. Models with communications
More information99 Washington Street Melrose, MA Phone Toll Free Visit us at
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 48VTR Product Info Page Instruction Manual English / Español
More information02/11/2015
CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint
More informationSA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection
SA00 SA00 SA00 SA00 Temperature Limit ontroller SA00L FM APPROVED SA00L General Description The SA00L is a FM approved high limit or low limit controllers. The SA00 is a socket mounting type temperature
More informationTEMPERATURE CONTROLLER
TEMPERATURE CONTROLLER E5CX(-H) DIN-sized super-compact (48 x 48-mm) Temperature Controller Featuring Advanced PID Control Advanced PID control with two degrees of freedom improves stability and response
More informationSerie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)
Serie 5000 Tel. +1 (0)5 222 Fax +1 (0)5 222 12 PRODUCT INTRODUCTI PRODUCT INTRODUCTI 5 Series programmable temperature controller is FineTek's mid-range series of controllers. It uses a 12bit analog /
More informationMICRO CONTROLLER E Z SERIES
Instruction Manual MICRO CONTROLLER E Z SERIES TYPE: PYZ 4 5 7 9 Fuji Electric Co.,Ltd. INP-TN2PYZDe-E INTRODUCTION You are now the owner of Fuji's Digital Temperature Controller. Before using, be sure
More informationINSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A
INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER Thank you for your purchase of our Microcomputer based Temperature Indicating Controller. This manual contains instructions
More informationInstruction manual Micro-computer based digital indicating controller
Instruction manual Micro-computer based digital indicating controller JCS-33A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual.
More information7EF/7HF/7EC/7ES Temperature Controllers
7EF/7HF/7E/7ES Temperature ontrollers Dual 4 Digit LED Display Universal Input (6 T/, RTD, mv, V, ma) Autotuning NEMA 4X 100 to 240 Vac Switching Power Supply Algorithms for Heat or Heat/ool ontrol 2 Independent
More informationModel 96VTR ¼ DIN Process Controller
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 96VTR Product Info Page INSTRUCTION MANUAL Model 96VTR ¼ DIN
More informationINSTRUCTION MANUAL Micro-computer based digital indicating controller
INSTRUCTI MANUAL Micro-computer based digital indicating controller TP4A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution
More informationInstruction manual Temperature Controller KT7
Instruction manual Temperature Controller KT7 No. KT71E7 201.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. SAFETY PRECAUTIS Be sure
More informationGCS-300 No.GCS31E
INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller GCS-00 No.GCS1E 200.0 To prevent accidents arising from the use of this controller, please ensure the operator receives this manual.
More informationHigh Resolution Temperature Controller REX-F9000. Instruction Manual IM9000F01-E5 RKC INSTRUMENT INC.
High Resolution Temperature Controller REX-F9000 Instruction Manual RKC INSTRUMENT INC. IM9000F01-E5 All Rights Reserved, Copyright 1999, RKC INSTRUMENT INC. Thank you for purchasing this RKC product.
More informationTAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller
TAIE FY Series Digital PID Controller FY600 (96mm X 48mm) Application:Control temperature,humidity, FY series controllers are microprocessor based controllers. Which have been Designed with high accuracy
More informationUDC 700 Universal Digital Controllers and Indicator Specifications
UDC 700 Universal Digital Controllers and Indicator Specifications 51-52-03-28 August 2002 Overview The UDC 700 is a 1/32 DIN (49 x 25 mm) controller which combines a high degree of technology and quality
More informationARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER
ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER AI-208 (V7.6) User Manual I. Model Code Symbol The type of AI-208 is made up of 4 parts: AI-208 A G L2 Part 1 (Series) Part 2 (Size) Part 3 (Oupt) Part 4
More informationInstruction manual for DIN rail mounting type indicating controller DCL-33A
Instruction manual for DIN rail mounting type indicating controller DCL-33A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution
More informationVERTEX F4 Instruction Manual
VERTEX F4 Instruction Manual 02/2018 The VERTEX F4 controller 1/16 DIN is our LOW COST yet HIGH SPEC controller. Configurable on input between various thermocouples from the keypad by the user or when
More informationSpecification , July 2015
Technical Information PrecisionLine Controllers EDC21 / EDC22 / EDC23 EASYSET DIGITAL CONTROLLERS Specification 51-52-3-48, July 215 Introduction The EDC21, EDC22 and EDC23 controllers provide precise
More informationCN4800 Series CONTROLLER
CN4800 Series CONTROLLER Operator's Manual PV SV OUT1 OUT2 ALM1 ALM2 SEL M1791/0502 Contents I. PREPARING THE OPERATION... 4 1. THE BASIC INSTALLATION PROCEDURE... 5 2. CHECK OF SPECIFICATIONS... 6 2.1
More informationUDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS
UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 4/01 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1000 and UDC1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers
More informationSeries Temperature Controller Instruction Sheet
Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep
More informationTAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller
TAIE FY Series Digital PID Controller FY900 (96mm X 96mm) Application:Control temperature,humidity, FY series controllers are microprocessor based controllers. Which have been Designed with high accuracy
More informationMC-5 Series Micro Processor Temperature Controller
MC-5 Series Micro Processor Temperature Controller Application Plastic, rubber, equipment Injection molding machinery Extruding machinery Mold temperature controllers Vacuum forming Blow molding (Thermo
More informationINSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200
INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200 PV PV AT AT OUT1 OUT2/HB A1 A2 OUT1 OUT2/HB A1 A2 MODE OUT MODE OUT GCD GCR Preface Thank you for the purchase
More informationNov 08 PRODUCT SPECIFICATION SHEET
Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 Nov 08 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN
More informationNon-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100
INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller 1 GCS-00 No.GCS1E 200.11 To prevent accidents arising from the use of this controller, please ensure the operator receives this manual.
More informationTemperature Controller
E5AN Temperature Controller Temperature Controller OMRON Corporation Industrial Automation Company Industrial Devices and Components Division H.Q. Measuring Components Department Shiokoji Horikawa, Shimogyo-ku,
More informationTerwin Instruments Ltd.
Terwin Instruments Ltd. Temperature PID Controllers MC-x8 OPERATIONAL MANUAL MC 8 / MC 8 / MC 8 MC 8 / MC 88 ( Display unit & Indication lamps ~ =Measured value display =Set value dispaly Alarm output
More informationCB103/CB403/CB PRODUCT CHECK 2. MOUNTING - * - / /Y INSTRUCTION MANUAL WARNING. 2.1 Mounting Cautions CAUTION RKC INSTRUMENT INC.
Digital Controller CB/CB4/CB9 INSTRUCTI MANUAL IMCBE7 Thank you for purchasing this RKC product. In order to achieve maximum performance and ensure proper operation of your new instrument, carefully read
More informationWarning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER
INSTRUCTI MANUAL DIN RAIL MOUNTING TYPE INDICATING CTROLLER 1 DCL-A DC No.DCLDCE1 2007.01 Thank you for purchasing our DIN rail mounting type indicating controller DCL-A DC. This manual contains instructions
More informationSR70 (SR ) Series Digital controller Instruction Manual
SR70 (SR71 72 73 74) Series Digital controller Instruction Manual Thank you for purchasing the Shimaden SR70 Series. Please check that the delivered product is the correct item you ordered. Please do not
More informationTempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications
Instruction Manual Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Manual PCT30006, Revision 9/20/2016 The PCT30006 control enclosure incorporates
More informationUniversal controller for panel mounting Models CS6S, CS6H, CS6L
Accessories Universal controller for panel mounting Models CS6S, CS6H, CS6L WIKA data sheet AC 85.08 Applications Plant and industrial furnace construction Process engineering Plastics technology and processing
More informationDIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL
DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL Preface Thank you for purchasing our Digital indicating controller FCS-23A. This manual contains instructions for the mounting, functions, operations
More informationCommunications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02
Temperature Controller Fuzzy Self-tuning Temperature Controller with Advanced PID (2-PID) Control DIN-size: 6 x 6 mm (E5AJ), 2 x 2 mm (E5BJ), 4 x 4 mm (E5CJ), 4 x 6 mm (E5EJ) Fuzzy self-tuning and Auto-tuning
More informationTC515 and TC600 Installation Manual. a Winters company
THERMOLINE TEMPERATURE CONTROLLERS TC515 and TC600 Installation Manual a Winters company Guarantee 12 months Congratulations on the purchase of this new product. Special care with the design, workmanship
More informationDCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.
INSTRUCTI MANUAL DIN RAIL MOUNTING TYPE INDICATING CTROLLER DCL-A No.DCL1E5 200.08 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. SAFETY
More information1. PRODUCT CHECK 2. MOUNTING - * - / /Y
Digital Controller /CB/CB/CB/CB9 ISTRUCTI MAUAL IMCB-E Thank you for purchasing this RKC product. In order to achieve maximum performance and ensure proper operation of your new instrument, carefully read
More informationTempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications
Instruction Manual Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Manual PCT-3000 Revision 9/2014 The PCT-3000 series control console incorporates
More informationSYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1
SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1 Jun. 2007 Auber Instruments, 730 Culworth, Alpharetta, GA 30022 www.auberins.com e-mail: auberins@gmail.com Tel: 404-291-6298 WARNING
More informationSHIMADEN DIGITAL INDICATORS
Shimaden, Temperature and Humidity Control Specialists C %RH MICROPROCESSOR-BASED SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.25% High Accuracy Indication User-Selectable
More information1. PRODUCT CHECK 2. MOUNTING
Digital Controller /CB/CB/CB/CB ISTRUCTI MAUAL IMCB-E Thank you for purchasing this RKC product. In order to achieve maximum performance and ensure proper operation of your new instrument, carefully read
More informationAutomationDirect. PC35 Configuration Sheet
Part#: Project: AutomationDirect PC35 Configuration Sheet Name: Date: Main Setpoint (): Cycle 5 INPUT DEFAULT CODE/VALUE Type 1 Dppo OFF Unit [ Offs 0 Spll -150 Spkl 1370 Rsll -150 Rskl 1370 Cycle 6 I/O
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit
ABB MEASUREMENT & ANALYTICS DATA SHEET C50 1/16 DIN controller / alarm unit 2 C50 1/16 DI N CON TROLL ER / AL ARM U NIT DS/C 50-E N RE V. M Measurement made easy C50 the 1/16 DIN controller to suit your
More informationINSTRUCTION MANUAL FOR TOUCH PANEL MONITORING UNIT CMT-220-K
INSTRUCTION MANUAL FOR TOUCH PANEL MONITORING UNIT PREFACE Thank you for your purchase of our Touch panel monitoring unit. This manual contains instructions for the mounting, functions, operations and
More informationGeneral Specifications
General Specifications GS J0H-0E Model MVHK Digital Limit Alarm (DC Type) with Active Color PV Display General This plug-in type Digital Limit Alarm for DC input receives DC current or DC voltage signal.
More informationMulti-point Digital Controller MA900/MA901. Initial Setting Manual IMR01H03-E4 RKC INSTRUMENT INC.
Multi-point Digital Controller MA900/MA901 Initial Setting Manual RKC INSTRUMENT INC. IMR01H03-E4 !"Modbus is a registered trademark of Schneider Electric.!"Company names and product names used in this
More informationOperation manual for BOD-80. 3, Hagavish st., Holon,Israel Tel: , Fax: Page 1 of 6 pages
Operation manual for BOD-80 Page 1 of 6 pages CONTROLS AND COMPONENTS OVERVIEW Remark: Please turn on the cooling system below 30ºC degrees Page 2 of 6 pages Main Temperature Controller This control is
More information+ A B V B NO NC V COM PV PV
+ - A + B B - V + - NO NC COM + - + - V + - PV PV Ramp Soak 100 70 50 30 3 5 3 8 5 3 Minute Steam Heating Sensor Cooling Water PID Hotplate Specifications Input power supply AC 100 to 240V, 50/60Hz, DC
More informationExample of Applications and Parameter Functions
PX-series digital temperature controller Example of Applications and Functions ECNO:1158 I. Example of Applications 1 Controlling both heating and cooling with a single controller Only one controller is
More informationSeries Digital Controller Instruction Sheet
216/3/11 Series Digital Controller Instruction Sheet Thank you very much for purchasing DELTA DTC Series Temperature Controller. Please read this instruction sheet before using your DTC series to ensure
More informationInterchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F
Temperature Controller 1/16 DIN Sized Controller Offers Selectable Control, Alarm Modes Accurate to ±0.5% of full scale Multiple temperature scale ranges allow flexibility to match application Field-selectable
More informationABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements
Specifications COMMANDER 150 Universal Process Indicator High visibility 6-digit LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement
More informationTemperature Controller SA100. Initial Setting Manual IMR01J03-E1 RKC INSTRUMENT INC.
Temperature Controller SA100 Initial Setting Manual RKC INSTRUMENT INC. IMR01J03-E1 Modbus is a registered trademark of Schneider Electric. Company names and product names used in this manual are the trademarks
More informationDC1000 Series Digital Controller Product Manual August 2005
DC1000 Series Digital Controller Product Manual 51-52-25-113 August 2005 Industrial Measurement and Control Copyright, Notices and Trademarks Printed in Taiwan - Copyright 2005 by Honeywell Revison 1 -
More informationMODEL MP-1S OVERSPEED UNIT
MODEL MP-S OVERSPEED UNIT SPEIFIATIONS Model Spec. ode upon delivery/add l Spec. ode( not requested, leave blank ) MP-S- - - - Hysteresis Set up Monitor Range Input Signal No. of Input Pulse Trigger Mode
More informationMODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points
Digital Panel Meters 47 Series PULSE INPUT TOTALIZER (6-digit, LED display type) Functions & Features 6-digit digital panel meter 1/8 DIN size Process integration/totalization with scaling factor adjustment
More informationMODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power
Digital Panel Meters 47 Series THERMOCOUPLE INPUT DIGITAL PANEL METER (4-digit, LED display type) Functions & Features 4-digit thermocouple input digital panel meter 1/8 DIN size Moving average function
More informationTable of Contents SECTION PAGE
Table of Contents SECTION PAGE SECTION 1 INTRODUCTION................... 1.1 Description.............................. 1.2 Features................................ 1.3 Models.................................
More informationKC-400 KC-600 KC-700 KC-800 KC-900
KCE Series Micro Processor Controller Operation Manual KC-400 KC-600 KC-700 KC-800 KC-900 KCE Contents 1 Safety Guide... 1 1.1 Specifications... 2 1.2 Model Selection Guide... 3 1.3 Model Guide... 3 1.4
More informationUDC100 Universal Digital Controller Specifications
UDC100 Universal Digital Controller Specifications 51-52-03-29 November 1999 Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines
More informationSeries SHR-5620 Digital Display Volumetric Meter Operation Instruction
Series SHR-5620 Digital Display Volumetric Meter Operation Instruction Version: 5620-110722 1. Introduction SHR-5620 Digital Display Volumetric Meter,Produced by full-automatic chip mounter with surface
More informationOVEN INDUSTRIES, INC.
OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and
More informationUDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS
UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 11/98 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1000 & UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers which
More information± 3% or better at 40%RH and 23ºC [73ºF] 0.8 mm 2 [18 AWG] minimum
Room Humidistat Features: Attractive modern look with large LD and backlight Icons driven information and 1 line of text External humidity sensor input Humidification and dehumidification indicator Multi
More informationThank you for purchasing an Autonics product.
User Manual Preface Preface Thank you for purchasing an Autonics product. Please familiarize yourself with the information contained in the Safety Precautions section before using this product. This user
More informationCEMA CM20 Series Digital Controller Operation Manual CM24 CM22 CM21 CM23 CM25
CEMA CM20 Series Digital Controller Operation Manual CM24 CM22 CM21 CM23 CM25 Contents 1 Safety Guide... 1 1.1 Specifications... 2 1.2 Model Selection Guide... 3 1.3 Model Guide... 3 1.4 Optional Spec....
More informationPreface USER MANUAL. Copyright Reserved Autonics Co., Ltd. I
Preface USER MANUAL Copyright Reserved Autonics Co., Ltd. I Preface II Copyright Reserved Autonics Co., Ltd. Preface Preface Thank you for purchasing an Autonics product. Please familiarize yourself with
More informationTemperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI
HumiTherm Ultra Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping Mapping Unit Micro PLC Control Unit Touch Panel Touch Operation Panel PPI HumiTherm Ultra GSM Module
More information1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad.
INSTRUCTI MANUAL (EXCERPT) Digital Indicating Controller ACS-13A- /A (For Use with the Infrared Temperature Sensor RD-500) No.ACS11AE1 2011.07 The digital indicating controller ACS-13A /A is an exclusive
More informationDIN RAIL MOUNTED INDICATING CONTOLLER DCL-33A INSTRUCTION MANUAL
DIN RAIL MOUNTED INDICATING CONTOLLER DCL-A INSTRUCTION MANUAL Preface Thank you for purchasing our DIN rail mounted indicating controller DCL-A. This manual contains instructions for the mounting, functions,
More information203RE ph v 1.0 Instructions
203RE ph v 1.0 Instructions \\Elmacron-server\gemensam\Instruktioner\Instruktioner i Word\203RE\Engelska\203 RE ph_eng.doc TABLE OF CONTENTS INTRODUCTION... 2 DEFAULT SETTINGS... 2 INSTALLATION... 3 Casing...
More informationLow Temperature Zirconia Oxygen Analyzer
Data Sheet SS/ZDT FG Issue 10 Low Temperature Zirconia Oxygen Analyzer ZDT FG Environmental certification MCERTS SIRA certificate MC99000 1/00 User-friendly language options selectable system alarms comprehensive
More informationESSEX ENGINEERING CORPORATION
WATER/WASTEWATER TREATMENT CONTROL SYSTEMS AND SUBSYSTEMS 2000 SERIES CONTROL SYSTEMS: 2000 series are for surface mounting inside a control cabinet Model 2024 Electronic Alternator Duplex (two pump) pump
More informationProcess & TeMPerATUre UniversAl input DigiTAl MeTers
Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min
More informationCM 8. Temperature controllers with compact dimensions. Manual 42/61-71 EN Rev. 01
CM 8 Temperature controllers with compact dimensions Manual 42/61-71 EN Rev. 01 Table of contents Page Remarks... 2 Installation and commissioning 1. Identifying the instrument... 3 2. Selecting installation
More informationINSTRUCTIONS FOR THE 8500 SERIES MICROPROCESSOR BASED TEMPERATURE CONTROL
INSTRUCTIONS FOR THE 8500 SERIES MICROPROCESSOR BASED TEMPERATURE CONTROL December, 1998 Page 1 949-1275-1 TABLE OF CONTENTS MODEL IDENTIFICATION... 4 INSTALLATION... 4 WIRING... 5 FRONT PANEL KEY FUNCTIONS...
More information(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA
TC3YF Freezing/ type DIN W72 H36mm Freezing/ type Features ON/ Control Input specification - Basic specification: NTC(Thermistor), Option: RTD(DPt100Ω) Temperature display range NTC type: -40.0 to 99.9
More informationJIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.
INSTRUCTI MANUAL MICRO-COMPUTER BASED DIGITAL INDICATOR JIR-31-M No.JIR31E6 28.8 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. SAFETY
More informationThe range of ATR243 controllers comes in three versions. Refer to the table below to easily select your preferred model.
Summary 1 Introduction... 3 2 Model Identification... 3 3 Technical Data... 4 3.1 General Features... 4 3.2 Hardware Features... 4 3.3 Software Features... 5 4 Dimensions and Installation... 5 4.1 Panel
More informationDT968C C.T. BATH CONTROLLER
DT968C C.T. BATH CONTROLLER MANUAL (DT968C, 9-5-01) ICD/HEATEFLEX Page 1 DT968C CONSTANT TEMPERATURE BATH CONTROLLER The Model DT968C is a microprocessor based controller/timer. It monitors temperature
More informationJIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.
INSTRUCTION MANUAL MICRO-COMPUTER BASED DIGITAL INDICATOR JIR-31-M No.JIR31E3 24.7 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. SAFETY
More informationPROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS
PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min
More informationR1000 / R1040 / R1080
R1000 / R1040 / R1080 1 Zone Temperature Controller: Heat-only Heating-off-cooling Three-point stepping DIN-Format: 96mm x 96mm / 48mm x 96mm / 96mm x 48mm Description and operating manual ELOTECH Industrieelektronik
More information