Smoke and Fire Curtains

Size: px
Start display at page:

Download "Smoke and Fire Curtains"

Transcription

1 Smoke and Fire Curtains NFPA UL Datasheet firecurtaintech.com

2 SMOKE AND FIRE CURTAINS Fire Curtain Technologies distributes a wide range of fire and smoke protective curtains to protect every type of building application. Fire and smoke protective curtains provide means of escape and boundary protection to providing a building with a system that offers effective fire and smoke compartmentalization. Our fire and smoke protective curtains offer various solutions to architects, engineers, consultants and specifiers providing the ability to design complex buildings that adhere to fire regulations and offer protection against smoke FIRE CURTAINS Product Name Housing type Max width Max drop Certification Compliance Automatic Fire Protective Curtain Single unit 19.5 Multi unit 19.5 Automatic Fire Protective Smoke Curtain Multi unit hours UL 10D, UL 1784 Automatic Fire Curtain FireMaster FM Dimensions ( ft ) Single unit / 18 Multi unit 16 / 12 / hours 1-3 hours UL 10D, UL EN , EN EN , EN SMOKE CURTAINS Dimensions ( ft ) Product Name Housing type Max width Max drop Certification Compliance Automatic Fire Protective Smoke Curtain Multi unit hours UL 10D, UL 1784 Automatic Smoke Sealed Curtain SD Automatic Smoke Curtain SM5 SI-N Single unit SI-L Single unit / 18 Single unit Multi unit 1-3 hours 1-3 hours UL 10D, UL 1784, EN EN , EN EN Fixed Draft Curtain SM - ST hours EN , EN

3 BENEFITS AND FEATURES BENEFITS SMOKE CURTAINS Increase the time available for occupants to escape the building since they reduce the travel distances. Are a cost effective solution to zoning a building. Assist the emergency services by containing or channelling the smoke into predetermined areas. Limit travel and overcooling of smoke, reducing the risk of cold smoke dropping to low level and obscuring vision. FIRE CURTAINS Seal off an area to contain a fire and to prevent it from spreading. Automatically deploy upon receipt of a signal from the fire-alarm panel, and automatically retracts when the signal has stopped. Retain fire integrity in an emergency but allow complete freedom of passage when not in use. FEATURES Fire Curtain Technologies smoke and fire curtains are fully tested and certified to the latest fire regulations and building design technology. Fire Curtain Technologies provides a wide range of options: All system components (headboxes, fabric, bottom bars, drive systems) can be customized. All fire and smoke curtains can operate as an integrated part of a smoke control and fire management scheme, with emergency power units and the facility to interface directly with a fire control panel. Gravity Fail-safe Unwinds curtain to its operational position without the need for power. Fire curtains are manufactured under the ISO 9001 quality standard by Colt Group International. 1 1 There are four main components: 1 Head box 2 Roller with fabric 3 Side guides 4 Bottom bar with seal

4 UNIVERSAL FEATURES HEAD BOX 6 12 Housing type SI / DH / DV The head box is made from galvanized steel and comprises stiffening brackets and a movable cover plate. Head boxes are also pre-assembled so to easily accommodate a roller or rollers. The bottom access covers are attached by means of screws on the side of the housing SI DH DV Single Double horizontal Double vertical Depending on the unit height and temperature classes (60 or 180), the housing type is either type N or type L Cloth SI-x Single headbox Headbox dimensions (m DH-x Double horizontal headbox Configuration and sizes: DV-x Double vertical headbox Housing dimensions (ft) Single (type SI) Where a limited size of barrier is required (e.g. a fire door or shutter) Width [B] Height [H] SI-N / SD-N 6 6 SI-L / SD-L 7 7 1/4 Double vertical (type DV) Where continuous runs with overlapped fabric to form a continuous barrier are required. Width [B] Height [H] DV-N 6 10 DV-L 7 12 Double horizontal (type DH) Where continuous runs with overlapped fabric to form a continuous barrier are required and where there is a premium on space under the ceiling. Width [B] Height [H] DH-N 10 6 DH-L /4 ROLLER MOTOR Technical information The roller is a essential component of the fire protective curtain and provides, in connection with the controls, a safe function of the fire protective curtain. Direct current motor DC motor with planetary reduction gears G type roller unit Gravity fail safe H type roller unit Gravity fail safe with intermediate stops

5 UNIVERSAL FEATURES CLOTH The fabric is fire-resistant and comprises one of the following options: 60 minute Heat-stabilized fabric achieving 60 minutes fire integrity. 120 minute Heat-stabilized fabric with a stainless steel inlay achieving 120 minutes fire integrity and 30 minutes limitation of the radiation of heat. 180 minute Heat-stabilized fabric with a stainless steel inlay, achieving 180 minutes fire integrity and 30 minutes limitation of the radiation of heat. 60 minute material 120 and E180 minute material OVERLAPS SI with no overlap Overlap for DH type curtains Overlap for DV type curtains CORNERS Type SI Type DH Type DV

6 UNIVERSAL FEATURES BOTTOM BAR Consists of a contoured profile made of galvanized steel sheet. It is attached to the lower end of the cloth using rivets and serves: Cloth 2 K bottom bar 3 Additional weight 4 Spring 5 Cover strip 1 As a weight to draw the curtain down to its working position To ensure that the curtain remains taut when it is deployed To ensure there is a seal against the floor. K bottom bar profile UK Designed for commercial applications, comprising steel angle with an additional aluminium profile connected to a spring in order to accommodate any unevenness in the floor in order to minimize smoke leakage Cloth 2 U bottom bar 3 Additional weights 4 Round steel Ø10 mm 5 Spring 6 Cover strip 1 UK bottom bar profile SIDE GUIDE A side guide system is nearly always fitted and provides a seal between the sides of the curtain fabric and the walls, ensuring that any positive or negative pressures created by a fire will be resisted by the curtain and so that it won t deflect significantly. Side guides can be integrated either into or onto a wall / soffit or into a recess / niche. COLT side guide roller system has been designed to ensure that the curtain will move to its closed position easily even when there are significant air velocities around the curtain. Side guide assembly options min.= 1/32 in max. = 1/2 in min. =1/32 in max. = 1/2 in min. 3 in Onto soffit Onto wall Into niche

7 FIRE PROTECTIVE CURTAIN AUTOMATIC FIRE CURTAIN The Fire Protective Curtain is an automatic fire curtain that prevents fire and smoke from transferring from one part of a building to another. In the event of a fire, the Fire Protective Curtain forms a temporary barrier which assists people escaping from a burning building. It operates automatically when interfaced with the building fire alarm system. APPLICATIONS: Fire protective curtains are used in all industrial and commercial buildings, e.g. shopping centers, office buildings, atria, etc. The Fire Protective Curtain is certified and labeled to UL 10D Fire resistance 60 / 180 minutes The fire protective curtain consists of a roller covered with a fiberglass fabric which is incorporated into a galvanized steel housing. The roller unit incorporates a motor, planetary gearbox and internal microprocessor. The microprocessor monitors the rest position and independently regulates the closing speed to a maximum of 0,15m/s (6 in / sec). The housing is equipped with specially developed reinforced brackets, which maintains integrity at high temperatures. The bottom of the housing is closed off with a panel which allows the entire length of the system to be accessed. The system is equipped with side guides. The design ensures that the required compartmentalization is achieved. There are no visible fasteners either on the underside of the housing or on the front of the side guides. At the bottom of the curtain a bottom bar is attached which serves to ensure that the curtain operates as designed and also that it remains stable when unrolled. Furnace testing in accordance with UL 10D, EN Smoke tightness tests Materials class: A2-s1, d0 Quality of cloth 1800 F Glass fabric 2200 F Glass fabric with coating and stainless-steel inlay Virtually invisible The bottom bar makes contact with the floor when the curtain is deployed creating a smoketight seal with the floor. There are different bottom bars available for different applications. The curtain headbox and side guides can be polyester powder coated in all RAL colors. The fabric is silver grey. The unit can be configured with mounting brackets either for wall or ceiling mounting. FS, FR and FD PIN SIDE GUIDES with integrated seals Manufactured in accordance with ISO 9001:2008

8 SMOKE SEALED CURTAIN FIRE PROTECTIVE CURTAIN SMOKE CERTIFIED The SD Smoke Sealed Curtain is designed to restrict the passage of smoke from spreading It operates automatically when connected. APPLICATIONS: Smoke sealed curtains are used in all industrial and commercial buildings, e.g. shopping centers, office buildings, lift landing lobbies, hospitals, retirement home, atria, etc. The Smoke Sealed Curtain is certified and labeled to UL 10D and EN and further certified to UL 1784 Fire resistance + compartmentation 60 / 180 minutes Furnace testing in accordance with UL 10D, EN Smoke tightness test UL 1784 Materials class: A2-s1, d0 Quality of cloth 1800 F Glass fabric 2200 F Glass fabric with coating and stainless-steel inlay Virtually invisible FS, FR and FD PIN SIDE GUIDES with integrated seals Manufactured in accordance with ISO 9001:2008 The Smoke Sealed Curtain consists of a roller covered with a fiberglass fabric which is incorporated into a galvanized steel housing. The roller unit incorporates a motor, planetary gearbox and controls electronics with a microprocessor. The microprocessor monitors the rest position when rolled up and independently regulates the closing speed to a maximum of 0,15 m/s (6in / sec). The housing is equipped with specially developed reinforced brackets, which maintains integrity at high temperatures. The bottom of the housing is closed off with a panel which allows the entire length of the system to be accessed. The system is equipped with FD side guides. Their special tight design ensures that the required compartmentalization is achieved. There are no visible fasteners either on the underside of the housing or on the front of the side guides. At the bottom of the curtain a bottom bar is attached which serves to ensure that the curtain operates as designed and also that it remains stable when unrolled. The bottom bar makes contact with the floor when the curtain is deployed, creating a smoketight seal with the building structure. There are different bottom bars available for different applications. The curtain headbox and side guides can be polyester powder coated in all RAL colors. The fabric is silver grey. The unit can be configured with mounting brackets either for wall or ceiling mounting. *Also available with Emergency Egress.

9 FIXED SMOKE CURTAIN FIXED DRAFT CURTAIN A Fixed Draft Smoke Curtain contains smoke and heat in the case of fire. Per NFPA 92B, Draft curtains are generally used to channel or contain smoke that is attached to the underside of the ceiling and protrude a limited distance downward. A fixed smoke curtain consists of several overlapping curtains attached together to provide a continuous run. They are connected together and to the building by means of clamps and angle pieces. The bottom of the cloth is weighted, ensuring that the curtain remains taut and reducing the amount of deflection through air currents. Smoke resistance 60 / 120 minutes >2500mm Height from 500mm to max. 0.6 fixing anchor W-FA, type /100/2.0 angle 5/10 rivet 10/30/10/1.5 clamp profile Duo adhesive tape Coupling piece Smoke curtain cloth Galvanised steel bar 26.9mm dia (3/4 ) Coupling piece Floor level The installation angles and the clamping profiles are predrilled to accept rivets. The connecting pieces have a continuous predrilled hole pattern, enabling fast and easy assembly of the curtain fabric. The bottom bar has a loop to accommodate the weight. SM-ST system can be used to close off a scheme of movable smoke curtains position below it, by clamping directly onto the housing of the movable smoke curtain. Fixing brackets, clamping profiles and bottom bars are all in galvanized steel. The curtain overlaps can be attached to one another using a spray adhesive approved by MPA Stuttgart, which seals the flaps tightly to to enhance the appearance of the surface of the curtain. The SM-ST system is fixed to the building with approved fasteners at intervals of a maximum of 5 feet. Smoke curtain meets the requirements of EN Smoke tightness tests Materials class: A2-s1, d0 Quality of cloth 1800 F Glass fabric 2200 F Glass fabric with coating and stainless-steel inlay Manufactured in accordance with ISO 9001:2008

10 CONTROL PANEL CONTROL PANEL The control panel for automatic smoke and fire curtains operates as sub system to central Fire Alarm System (FAS) or can operate independently. Electrical Requirements (120VAC, 0.67Amps/ motor) NUMBER OF CONTROL GROUPS MODULE FOR ADDITIONAL FUNCTIONS SIGNALLING MODULE NUMBER OF CONTROL GROUPS MODULE FOR ADDITIONAL FUNCTIONS SIGNALING MODULE Optional Uninterruptable Power Supply Control panels can receive multiple alarm and manual/emergency control inputs to manage multiple zones with immediate full deployment, delayed full deployment, and immediate partial deployment with delayed full deployment. Systems can be fitted to be modified on-site or remotely by certified technicians. Additional functions include: Release via smoke detector / heat detector Release via button / hand control Re-opening of curtain for use by fire-fighters (fire access) Re-opening of curtain in emergency (fire egress) Monitoring of curtain via a safety bottom bar Line monitoring for wire-break and short circuit. Signaling outputs include: The module operates in conjunction with the auxiliary module and is prepared for connection of optional warning devices, e.g. a combined multi-tone siren and/or a strobe light.

11 EMERGENCY EGRESS Rest position (Curtain up) The function of the intermediate position is programmed into the control panel at the factory, onsite, or remotely by a certified technician. Drop 1 Hold Time Distance from floor to ntermediate position. Curtain remains in the HWD intermediate position before it continues down (Escape Delay). Hold time HWD LT-UP Item Code: Emergency switch to raise smoke or fire curtains following a fire alarm by any person. Flush mounting. With hook and screw fixing Including RU-E frame Stickers supplied separately Installed at a height of ft from FFL DOOR / GATE EMERGENCY EXIT GA-E housing To accommodate a WF / WN switch Flush mounting. Cream colour Drop 1 UPS Connected to the connection module. Sustains normal curtain operation to FAS for locally-required period of time. * Device may vary depending on system requirements FFL Working Position (curtain down)

12 RELEASE AND CONTROL COMPONENTS SMOKE AND HEAT SENSORS SMOKE SENSOR Photoelectric detection of smoke particles In accordance with EN 54-7 Optical smoke detector with alarm: clear LED, red when there is an alarm Operating voltage VDC Current consumption at rest approx 40μA/24V Operating range from -4 F to F, 10-95% RH Dimensions including base: H 2 in, Ø 4 in VDS no. G THERMO-DIFFERENTIAL DETECTOR Alarm indication by red LED Easy installation with quarter-turn fastener Protection against theft Insensible to wind and atmospheric pressure Nominal temperature 135 F Response class A1R to EN 54-5: Application temperature F Static reaction: F Voltage: V- Operating range from -4 F to 195 F, 10-95% RH 100Mm diameter, flat design with base only 2 3/8 in height (standard / relay base) VDS approval no. G STANDARD BASE With short spring to facilitate installation and maintenance. Designed to combat incorrect operation Surface or flush cable entry Dimensions: H 5/8 in, Ø 4 in CONTROL SWITCH DOOR / GATE EMERGENCY EXIT MANUAL CONTROL Button as the main alarm point with internal button to reset the alarm 0.03 in thin break glass to DIN 1249 Lockable case Dimensions: 5 in x 5 in x 1in (WxHxD) IP42 IP code Label Close fire curtain KEY SWITCH Key switch for rolling up of smoke or fire curtains following a fire alarm by an authorized person. Flush mounting. Prepared to accommodate a PHZ cylinder lock (in addition). Switching capacity 10A / 250V AC. With hook and screw fixing Including RU-E frame Stickers supplied separately EMERGENCY SWITCH Emergency switch to raise smoke or fire curtains following a fire alarm by any person. Flush mounting. With hook and screw fixing Including RU-E frame Stickers supplied separately Installed at a height of 35 in - 43 in from FFL

13 SIGNALS AND MONITORING SIGNALS Sounder with strobe light Sounder with Xenon strobe light, white plastic housing depending on different wiring even only as strobe light or sounder usable. Voltage : 24V DC Current: 40 ma Protection class: IP 45 Alarm volume level: Adjustable 10 to 109 dba Dimensions: Ø 4 in x4 in H Coloured dome: Orange Operating temperature: 5 F to 104 F Multi-tone siren Multi-tone siren with integrated strobe light in red plastic housing Knock-outs for cable Voltage : Current: Protection class: Dimensions: Coloured dome: 9-28V DC 20 ma IP55 Ø 4 in x 3 in H red Voice announcer Multi-tone siren with integrated strobe light in white plastic housing and orange LED. When activated, makes this announcement between the tones Voltage : 20-28V DC Sound output: 100 db (A) Language: 95 db (A) Current: 60 ma Protection class: IP45 Alarm volume level: 3 x 3 x 5 in (WxHxD) Dimensions: Ø 4 in x 4 in H Operating temperature: -13 F to 158 F KL Contact Safety MONITORING Provides protection either for people or for goods. One side has double-sided tape for direct attachment to the bottom bar. The homogeneous, highly insulating material made of PVC is equipped with two internal conductive contact surfaces. In the conductive elastomer there are two copper wires that enable low resistance readings at great lengths. Sectional dimensions: 1/4 in x 1 in Length: 4 in x 2 in Fixing the unit: Double-sided tape Response force: min. 4 N Contact travel: < 1/8 in Detection angle: < 122 F RL Optical Safety Red LED function display Consisting of optic sensor for object detection and monitoring of openings A 24 V to 240 V all-voltage sensor can be operated with either DC or AC voltage. High protection suitable for use in harsh environments. Including reflector and bracket General info: Max. operating range: Light source: Ambient light: 12m LED Lux Shines: When the beam is uninterrupted Flashes: When falling short of the functional reserve Off: When the beam is interrupted Technical data Voltage: No load current: Power consumption: Output Signal output: Switching voltage: Switching current: V AC/DC 8.5 ma 0,2W at 24V DC Relay, 1 inverter 230 volt AC max.2a

14 INSTALLATION OPTIONS Fire Curtain Technologies: 1 Self-Perform Provides installation and technique guides. Supports customer by and teleconference. 2 Outside Contractor Fire Curtain Technologies: Provides installation and technique guides. Supports outside contractor by and teleconference. Fire Curtain Technologies: 3 Onsite Supervision Technician visits on site and instructs local team to get the materials unpacked, inventoried and organized. Get projects started (or finished) with the install and even sign off on the work once completed as time and budget allow.

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1 PRODUCT DATA SHEET AUTOMATIC FIRE CURTAIN FM 1 AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1 FM-1 fire curtains are used where, if there is a fire, it is necessary to create a temporary barrier within an opening

More information

PRODUCT SPECIFICATION FireMaster Plus

PRODUCT SPECIFICATION FireMaster Plus PRODUCT SPECIFICATION FireMaster Plus 1 GENERAL 1.1 Scope Coopers FireMaster Plus active fire curtain barrier assemblies ( Fire Curtains ) are to be designed, fabricated, delivered, installed and commissioned

More information

PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex

PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex 1 GENERAL 1.1 Scope Coopers FireMaster NVS Horizontal Simplex active fire curtain barrier assemblies ( Fire Curtains ) are to be designed, fabricated,

More information

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped) In accordance with: BS EN 8524-1 BS EN 1634-1 BS 5234-2 BS EN 14600 BS EN 13501-2 BS EN ISO 1716 BS EN 13501-1+A1 BS EN ISO 14184-1 BS EN 12101 10 BS ISO 21927 9 Period of Fire Resistance: 180 minutes

More information

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES   LEADING THE WAY IN FIRE PROTECTION FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WWW.COOPERSFIRE.COM.AU LEADING THE WAY IN FIRE PROTECTION DESIGN SOLUTIONS THAT WORK FOR YOU Active Fire Curtain Barrier Assemblies comprise technologically

More information

PRODUCT SPECIFICATION FireMaster Plus Concertina

PRODUCT SPECIFICATION FireMaster Plus Concertina PRODUCT SPECIFICATION FireMaster Plus Concertina 1 GENERAL 1.1 Scope Coopers FireMaster Plus Concertina active fire curtain barrier assemblies ( Fire Curtains ) are to be designed, fabricated, delivered,

More information

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES  LEADING THE WAY IN FIRE PROTECTION FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION DESIGN SOLUTIONS THAT WORK FOR YOU CASE STUDY: FORTNUM & MASON LONDON UK Active Fire Curtain Barrier

More information

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES  LEADING THE WAY IN FIRE PROTECTION FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION DESIGN SOLUTIONS THAT WORK FOR YOU CASE STUDY: FORTNUM & MASON LONDON UK Active Fire Curtain Barrier

More information

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15. In accordance with: BS EN 12101-1+A1 BS EN 1363-1 BS EN 1634-3 BS EN 13501-4 BS EN ISO 1716 BS EN 13823 BS EN 13501-1 BS 476-6 BS 476-7 Period of Fire Resistance: 60 minutes (1 hour) integrity Classification:

More information

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM PART 1 - GENERAL 1.01 SUMMARY SECTION 08 34 84 ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM A. Section Includes: Fire protective elevator smoke containment curtain system designed to provide a tight-fitting,

More information

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES  LEADING THE WAY IN FIRE PROTECTION FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION MEANS OF ESCAPE PROTECTION CASE STUDY: SSE HYDRO GLASGOW UK

More information

CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c

CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c CI/SfB (68.5) February 2012 Intelligent security and fire protection SecureFire S e c SecureFire Flame Curtain Easily concealed, quickly enabled SecureFire Flame Curtain Intelligent automatic fire curtain

More information

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT:

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1136 Reissued 10/2017 This report is subject to renewal 10/2018. DIVISION: 07 00

More information

Technical Manual (European Standards)

Technical Manual (European Standards) Technical Manual (European Standards) Version 1.0 (0517) - System Overview - Installation - Maintenance & Troubleshooting - Manufacturing Information THE LEADING EDGE IN Smoke & Fire Curtains Office Tel:

More information

Conventional Fire Detection

Conventional Fire Detection SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct

More information

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

SAC 100 Automatic Smoke Curtain System. - Specifier Information - SAC 100 Automatic Smoke Curtain System - Specifier Information - CONTENTS 1. Introduction Page 3 2. Construction and Method of Operation Page 5 3. Performance 3.1. Resistance to Fire/Heat Page 6 3.2. Deflection

More information

PRODUCT SPECIFICATION FireMaster Concertina

PRODUCT SPECIFICATION FireMaster Concertina PRODUCT SPECIFICATION FireMaster Concertina 1 GENERAL 1.1 Scope Coopers FireMaster Concertina active fire curtain barrier assemblies ( Fire Curtain ) are to be designed, fabricated, delivered, installed

More information

Type CODE Speed Heating Cooling

Type CODE Speed Heating Cooling CLIMA CANAL HYBRID - Low Temperature radiator - Heating and cooling - Build-in height of 10 > 14.5 cm CLIMA CANAL - Low Temperature radiator - Heating - Build-in height of 8.5 > 13 cm 24V EC MOTOR High

More information

1 P a g e w w w. s m o k e c o n t r o l. c o. nz

1 P a g e w w w. s m o k e c o n t r o l. c o. nz PROPRIETARY ITEM: FIBERHSIELD EI60 AUTOMATIC OVERHEAD COILING TYPE FABRIC FIRE CURTAIN PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Fire alarm or smoke detector-activated, overhead coiling fabric

More information

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u PROPRIETARY ITEM: FIBERHSIELD S AUTOMATIC OVERHEAD PERIMETER TYPE FABRIC FIRE CURTAIN This master specification should be read in conjunction with How to specify fire curtains technical guide to be published

More information

FIRE DOOR. AlarmGard & FireGard. Preferred door solutions.

FIRE DOOR. AlarmGard & FireGard. Preferred door solutions. FIRE DOOR AlarmGard & FireGard Preferred door solutions. PREVENT SMOKE AND FIRE DAMAGE According to the National Fire Protection Association (NFPA), in 2014, there were 1,298,000 fires reported in the

More information

SMOKE & FIRE THE LEADING EDGE IN. Smoke & Fire Curtains

SMOKE & FIRE THE LEADING EDGE IN. Smoke & Fire Curtains THE LEADING EDGE IN > Automatic Smoke Curtains > Automatic Fire Curtains > Static Smoke Curtains > Accordion & Horizontal Curtains > Service & Maintenance L&F SMOKE & FIRE Smoke & Fire Curtains A Lowe

More information

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u PROPRIETARY ITEM: SMOKESHIELD S AUTOMATIC OVERHEAD PERIMETER TYPE FABRIC SMOKE CURTAIN PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Fire alarm or smoke detector-activated, overhead coiling fabric

More information

Operation & Maintenance Manual

Operation & Maintenance Manual Operation & Maintenance Manual for Model 2100 Fire+Smoke systems from Smoke Guard, Inc. 287 N. Maple Grove - Boise, ID 83704 Phone: (800) 574-0330 Fax: (208) 639-7851 E-Mail: info@smokeguard.com Website:

More information

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management Reyrolle Protection Devices 7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management 7XG3130 - RA30 Optical Arc Fault Sensor Features Compact rugged design One or two optical detectors High speed arc

More information

FireMaster. The Fire Curtain Barrier WITHOUT CORNER POSTS. Inspiring design, maximising floor space and increasing income.

FireMaster. The Fire Curtain Barrier WITHOUT CORNER POSTS. Inspiring design, maximising floor space and increasing income. W W W. C O O P E R S F I R E. C O M FireMaster CONCERTINA THE INVISIBLE ACTIVE FIRE CURTAIN BARRIER ASSEMBLY Cl/Sfb (31.5) Fire Doors The Fire Curtain Barrier WITHOUT CORNER POSTS Inspiring design, maximising

More information

SECTION FIRE ALARM SYSTEMS

SECTION FIRE ALARM SYSTEMS SECTION 16721 FIRE ALARM SYSTEMS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work

More information

Machine Protection Door Albany RP300. ASSA ABLOY Entrance Systems

Machine Protection Door Albany RP300. ASSA ABLOY Entrance Systems Machine Protection Door Albany RP300 ASSA ABLOY Entrance Systems Albany RP300 Rapid opening and closing ensures short cycle times up to 5 cycles per minute High reliability even after years of high numbers

More information

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20 PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible.

More information

ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS

ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS WWW.COOPERSFIRE.COM VII FIRE ACTIVE FIRE CURTAIN BARRIER FOR YOUR HOME AND COMMERCIAL PROPERTY. From architects to homeowners to commercial

More information

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5 PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible.

More information

2408/2900. Fire Guard

2408/2900. Fire Guard 2408/2900 Fire Guard Table of Contents Features and Additional Fire Opening Devices... 1 2408 Single-Point Hold Open Applications and Mounting Details... 2 2408 Track Assemblies, Arms and Components...

More information

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS)

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS) FIREIRE CURTAINSURTAINS Approved for use for 30m wide x 10m drop in accordance with AS1530.4 and AS1905.2 KEY FEATURES Fire tested in accordance with AS1530.4 (Up to 2 hours) GENERAL Fibershield automatic

More information

Emergi-Lite Orbis detectors

Emergi-Lite Orbis detectors Emergi-Lite Orbis detectors Emergi-Lite Orbis brings the latest in fire detector microprocessor technology to the Firetec and Eurofire systems. Non-addressable (conventional) smoke and heat sensors respond

More information

FIRE DOOR CLOSING SYSTEMS

FIRE DOOR CLOSING SYSTEMS FIRE DOOR CLOSING SYSTEMS AlarmGard & FireGard PREVENT SMOKE AND FIRE DAMAGE According to the National Fire Protection Association (NFPA), in 2014, there were 1,298,000 fires reported in the United States.

More information

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved Fire Guard SARGENT Manufacturing Company 2004, 2007 All rights reserved Fire Guard Table of Contents Features and Additional Fire Opening Devices............................1 2408 Single-Point Hold Open

More information

Won-Door FireGuard T H E P E R F E C T F I T I N A V A R I E T Y O F A P P L I C A T I O N S

Won-Door FireGuard T H E P E R F E C T F I T I N A V A R I E T Y O F A P P L I C A T I O N S Won-Door FireGuard T H E P E R F E C T F I T I N A V A R I E T Y O F A P P L I C A T I O N S Fire Safety By Design O N L Y T H E W O N - D O O R F I R E G U A R D C A N cover wide spans* heights up to

More information

2409/2900. Fire Guard

2409/2900. Fire Guard 2409/2900 Fire Guard Table of Contents Features and Additional Fire Opening Devices... 1 2409 Single-Point Hold Open Applications and Mounting Details... 2 2409 Track Assemblies, Arms and Components...

More information

FIRE & SMOKE CURTAINS

FIRE & SMOKE CURTAINS FIRE & SMOKE CURTAINS APPLICATIONS FOR FIRE AND SMOKE CURTAINS AND THE PRODUCT RANGE AVAILABLE WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION COMPANY PROFILE COOPERS FIRE Coopers Fire operates

More information

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! USER GUIDE English IMPORTANT PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal. Contents

More information

SECTION OVERHEAD COILING FIRE DOORS

SECTION OVERHEAD COILING FIRE DOORS SECTION 08331 OVERHEAD COILING FIRE DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on round Windows logo in top left corner,

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection Hart XL High Sensitivity Smoke Detection (HSSD) TM is a smoke detection system that is simple to install, commission, service and use yet remains brilliantly capable in

More information

intelligent solutions

intelligent solutions Alco is one of the leading intelligent solution providers of Fire Detection System. Security System and Public Addressing System in the United States of America. Based in California since 1992, we have

More information

Xenex Conventional Fire Detection & Alarm System

Xenex Conventional Fire Detection & Alarm System SECTI 4: page 1 Section 4: Xenex Conventional Fire Detection & Alarm System SECTI 4: page 3 Xenex system architecture Beam Transmitter Beam Receiver End of Line Call Point Smoke Detector Smoke Detector

More information

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 634

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 634 SECTION 08 33 23 OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 634 Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click

More information

Half-Dome. the Design-Tower. Compact

Half-Dome. the Design-Tower. Compact the Design-Tower 81 Compact 82 compact signal towers Visual-audible LED signal tower system in semicircular design Modern signal tower design Available to order pre-configured or with customised tower

More information

Ionisation single-tube smoke detector for duct mounting

Ionisation single-tube smoke detector for duct mounting Detectors Ionisation single-tube smoke detector for duct mounting 600 mm venturi tube is included., incl. end resistor (not RAC(M)) 9...33 V DC (via ABV control unit). 24 V AC ±15 % for RAC(M) models.

More information

FIREMASTER CONCERTINA TM

FIREMASTER CONCERTINA TM FIREMASTER CONCERTINA TM CONCERTINA TM THE INVISIBLE ACTIVE FIRE CURTAIN BARRIER ASSEMBLY WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION DESIGN SOLUTIONS THAT WORK FOR YOU CASE STUDY: OIL SEARCH

More information

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 635

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 635 SECTION 08331 OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 635 Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click

More information

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V. Signaling Devices Acoustic Signaling Devices 28 Optical Signaling Devices 30 26 Signaling Devices Acoustic Signaling Devices Acoustic Signaling Devices MSS300-SA SG 200 DS 10 LSN/GLT GLT GLT GLT Operating

More information

Pilot devices Stacklights Signal beacons

Pilot devices Stacklights Signal beacons Pilot devices Fast mounting of signal elements using bayonet fixing Easy changing of bulbs for each module without tools Up to 10 light elements possible with 2-sided mounting bracket Flexibility of signal

More information

CLIMA CANAL HYBRID CLIMA CANAL. Low Water Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING LOW TEMPERATURE SYSTEM / HEATING

CLIMA CANAL HYBRID CLIMA CANAL. Low Water Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING LOW TEMPERATURE SYSTEM / HEATING Low Water Temperature system CLIMA CANAL HYBRID: Build-in height of 3.94 > 5.71 CLIMA CANAL: Build-in height of 3.35 > 5.43 fan speed modulation via 0-10V signal CLIMA CANAL HYBRID LOW TEMPERATURE SYSTEM

More information

YOUR SINGLE SOURCE FOR EMERGENCY RESPONSE CLOSURE PRODUCTS

YOUR SINGLE SOURCE FOR EMERGENCY RESPONSE CLOSURE PRODUCTS YOUR SINGLE SOURCE FOR EMERGENCY RESPONSE CLOSURE PRODUCTS Coiling Fire Doors Firemiser Insulated Fire Doors SmokeShield Fire Doors SmokeShield Firemiser Doors Coiling Counter Fire Doors SmokeShield Counter

More information

External venetian blinds sunlight included 40% ENERGY SAVINGS WITH INTELLIGENT SUN SHADING

External venetian blinds sunlight included 40% ENERGY SAVINGS WITH INTELLIGENT SUN SHADING External venetian blinds...... sunlight included 40% ENERGY SAVINGS WITH INTELLIGENT SUN SHADING Quality WAREMA products stand for highest quality. We rely on highquality materials and first-rate workmanship

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection The Hart XL High Sensitivity Smoke Detection system (HSSD) is an aspirating fire detection system designed to give very early indication of an incipient fire condition.

More information

MODEL B2 INSTALLATION MANUAL

MODEL B2 INSTALLATION MANUAL RELEASE DEVICES GENERAL DESCRIPTION MODEL B2 INSTALLATION MANUAL S/N: The B2 Series Time Delay Release Devices are UL Listed, Canadian Listed, and CSFM Listed for use on rolling doors, single-slide and

More information

FAAST. Fire Alarm Aspirating Sensing Technology

FAAST. Fire Alarm Aspirating Sensing Technology FAAST Fire Alarm Aspirating Sensing Technology The FAAST range FAAST 8100e FAAST LT PipeIQ Next Generation Aspiration Detection Detection for Challenging Environments 3 in 1 Design, Confi guration and

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D2 MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D2 GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

Hardwired Alarm Accessories

Hardwired Alarm Accessories Hardwired Alarm Accessories Contents Wireless Door Contact for WGAP864 WGAP864WDCV2...3 Wireless PIR Sensor (Pet Immunity) For WGAP864 WGAP864WPIRV2...4 Dual Technology PIR / Microwave Detector ALH-PIRMW...5

More information

>WIRELESS> ALARM SYSTEM CR200

>WIRELESS> ALARM SYSTEM CR200 intrusion >WIRELESS> ALARM SYSTEM CR200 INTRUSION HOME SECURITY CR200 is a Modern, Effective and Versatile 20-zone Household Security System. It is packed with simple Plug & Play functionality, designed

More information

Model 600 Operation & Maintenance Manual

Model 600 Operation & Maintenance Manual Model 600 Operation & Maintenance Manual Including Semi-Annual Testing for your Smoke Guard System 287 N. Maple Grove - Boise, ID 83704 Phone: (800) 574-0330 (208) 639-7851 E-Mail: info@smokeguard.com

More information

Conventional Smoke Detectors KFAPO

Conventional Smoke Detectors KFAPO Kingfisher Company, inc. Conventional Smoke Detectors KFAPO Features: Wide operating voltage, 9-33 VDC Advanced electronic technology Flashing LED Magnetic test switch Proven detection performance Designed

More information

D-Tect 2 GJD300 Quad PIR Movement Detector

D-Tect 2 GJD300 Quad PIR Movement Detector D-Tect GJD0 Quad PIR Movement Detector Package Contents 3. Package Contains: x D-Tect x Drilling template for fixing holes x Allen Key 3 x 3.75mm wall plugs 3 x 3.75mm screws x Spare Sliding Curtains x

More information

Machine Protection Door

Machine Protection Door Machine Protection Door ASSA ABLOY RP2000 ASSA ABLOY Entrance Systems ASSA ABLOY RP2000 Type tested machine protection door with aluminum door blade Safety limit switches according to EN ISO 13849-1 and

More information

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ELECTRONIC SOUNDER STROBE Model : AVD-C407 ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an

More information

High-Speed Roll Doors An intelligent entrance solution for every location. ASSA ABLOY Entrance Systems

High-Speed Roll Doors An intelligent entrance solution for every location. ASSA ABLOY Entrance Systems High-Speed Roll Doors An intelligent entrance solution for every location ASSA ABLOY Entrance Systems We open the door to your business ASSA ABLOY Entrance Systems is the world s leading single-source

More information

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements INDEX 1 NETIC... 2 2 Door/Window detector MINI... 2 3 FOUR sensor... 3 4 Smoke detector... 3 5 Flood detector... 4 6 ILLumination sensor... 4 7 Lamp holder... 5 8 Siren... 5 9 Power meter & switch... 6

More information

SUPPLY,INSTALLATION,TESTING AND COMMISSIONING OF SPRINKLER SYSTEM AND FIRE ALARM SYSTEM FOR AIR INDIA LIMITED AT SHAMSHABAD, HYDERABAD.

SUPPLY,INSTALLATION,TESTING AND COMMISSIONING OF SPRINKLER SYSTEM AND FIRE ALARM SYSTEM FOR AIR INDIA LIMITED AT SHAMSHABAD, HYDERABAD. i 1 a SPRINKLER SYSTEM M S Pipes confirming to IS 1239 Pt - I Heavy grade with painting, suitable type of supports malleable srewed specials such as M S Reducers,Tees, elbows, flanges. Including cutting,

More information

RELEASE DEVICE CONTROLS

RELEASE DEVICE CONTROLS RELEASE DEVICE CONTROLS RELEASE DEVICE MODEL C+ INSTALLATION MANUAL UL LISTED CANADIAN LISTED CSFM: 7300-48:00 GENERAL DESCRIPTION: MADE IN THE U.S.A. S/N: The LM0-C+ Release Device/Control Panel is a

More information

ARCHITECTURAL SPECIFICATIONS

ARCHITECTURAL SPECIFICATIONS 1 G4.1 Entrance System Page 1 of 6, August 2017 DIVISION 10 - SPECIALTIES SECTION 10450 PEDESTRIAN CONTROL DEVICES Specifier Note: Coordinate and edit articles and paragraphs below to suit project requirements.

More information

1 P age w w w. s m o k e c o n t r o l. c o m. a u PROPRIETARY ITEM: FIBERHSIELD V AUTOMATIC OVERHEAD COILING TYPE FABRIC FIRE CURTAIN

1 P age w w w. s m o k e c o n t r o l. c o m. a u PROPRIETARY ITEM: FIBERHSIELD V AUTOMATIC OVERHEAD COILING TYPE FABRIC FIRE CURTAIN Fibershield V April 2015; Version 1.1 This product specification supersedes all previously issued documentation PROPRIETARY ITEM: FIBERHSIELD V AUTOMATIC OVERHEAD COILING TYPE FABRIC FIRE CURTAIN This

More information

High Performance Door Albany RP2000. ASSA ABLOY Entrance Systems

High Performance Door Albany RP2000. ASSA ABLOY Entrance Systems High Performance Door Albany RP2000 ASSA ABLOY Entrance Systems Albany RP2000 Type tested machine protection door with aluminum door blade Safety limit switches according to EN ISO 13849-1 and EN 62061

More information

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1. Data Sheet Ref: 90501085 WD-CS Water leak detection cable Technical Overview The WD-CS range of cable sensors are typically used to detect water leaks usually under floors, and are used in conjunction

More information

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM ANNEXUREIII D: FIRE PROTECTION SYSTEM SECTION ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM Supply, Installation, testing and commissioning of Analogue Addressable Fire Alarm Control panel with battery backup

More information

Machine Protection Door Albany RP300 / RP300 Wide / RP300 USD. ASSA ABLOY Entrance Systems

Machine Protection Door Albany RP300 / RP300 Wide / RP300 USD. ASSA ABLOY Entrance Systems Machine Protection Door Albany RP300 / RP300 Wide / RP300 USD ASSA ABLOY Entrance Systems HIGH SPEED Rapid opening and closing ensures short cycle time. HIGH RELIABILITY High reliability and low service

More information

Movement Detector GJD 300

Movement Detector GJD 300 Movement Detector GJD 300 Installation & Set Up Guide Introduction A CCTV event trigger utilising two independent passive infrared detectors combined in a T05 package. Both sensors have to trigger before

More information

Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd

Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd Smoke and Fire Curtains Performance Door sets for security and Fire resistant applications Introduction The Fire & Smoke curtains are the latest in fire protection systems to be added to the Doors (UK)

More information

Line Smoke Detector LRMX

Line Smoke Detector LRMX Line Smoke Detector LRMX Motorized detector head User-friendly commissioning via automatic selfadjustment Disturbance-protected operation via automatic electromechanical tracking of the detector head during

More information

ACTIVE FIRE CURTAINS INTISI7

ACTIVE FIRE CURTAINS INTISI7 ACTIVE FIRE CURTAINS INTISI7 For invisible fire partitions www.intisigroup.com Fire Engineered Fabrics How can anyone perfect anything? What does engineering require? From which approach we start???? INTISI

More information

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670 Bulletin AV-670 Series 670 Hood Monitor Specifications - Installation and Operating Instructions DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Phone: 219/879-8000 Fax: 219/872-9057

More information

EFBW series - BiWire Ultra control panel

EFBW series - BiWire Ultra control panel 4.2 Control panels and repeater panels EFBW series - BiWire Ultra control panel Eaton s new BiWire Ultra fire detection system is unlike any other standard conventional system as the panel, conventional

More information

FAAST. Fire Alarm Aspirating Sensing Technology

FAAST. Fire Alarm Aspirating Sensing Technology FAAST Fire Alarm Aspirating Sensing Technology The FAAST range FAAST 8100e FAAST LT PipeIQ Next Generation Aspiration Detection Detection for Challenging Environments 3 in 1 Design, Configuration and Monitoring

More information

Intelligent Addressable Fire Alarm System

Intelligent Addressable Fire Alarm System Intelligent Addressable Fire Alarm System Company Profile The Company established in 2003, is manufacturing security system devices with the brand name DEKON Security Technologies for the exclusivity of

More information

LEAKSTOPPER RANGE Multizone water leak detection systems

LEAKSTOPPER RANGE Multizone water leak detection systems LEAKSTOPPER RANGE Multizone water leak detection systems WHAT DOES THE PRODUCT DO? The LeakStopper detects water leaks and instantly triggers an alarm to warn you. It is capable of monitoring between 2

More information

Quick Selection Guide Fire Systems LSN Periphery

Quick Selection Guide Fire Systems LSN Periphery Local SecurityNetwork Easy wiring Auto configuration capability (self-learning mode) Central programming of all device configurations from the panel Flexible network structure (Loop, stub, T-tap & mixed

More information

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening. DIVISION 8 OPENINGS SECTION 08 33 23 PART 1 GENERAL 1.1 SECTION INCLUDES A. Overhead coiling counter fire doors. 1.2 RELATED SECTIONS A. Section 05500 - Metal Fabrications: Support framing and framed opening.

More information

Duct smoke housings, 4-wire D341/D341P and D342/D342P

Duct smoke housings, 4-wire D341/D341P and D342/D342P Duct smoke housings, 4-wire D341/D341P and D342/D342P en Installation manual Duct smoke housings, 4-wire Notices en 3 1 Notices These instructions cover the installation of the D341/D342 Duct smoke housings

More information

External venetian blinds

External venetian blinds External venetian blinds Doc.-No. 115002.01.2009/en Sun. Light. WAREMA. Security even in stormy times. Wind is essentially the result of equalisation of the different air pressures in adjacent air masses.

More information

Motorised Infrared Optical Beam Smoke Detector. User Guide

Motorised Infrared Optical Beam Smoke Detector. User Guide Motorised Infrared Optical Beam Smoke Detector User Guide EN 1. General Information 50cm 50cm 8-100m Ensure clear line of sight from Detector to Reflector Mount on solid surfaces (structural wall or girder)

More information

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes

More information

ISIS SAFETY SYSTEM Installation guide

ISIS SAFETY SYSTEM Installation guide ISIS SAFETY SYSTEM Installation guide CAUTION This information is designed to help suitably qualified personnel install and operate Mechan Safety equipment. Before using this product, read this guide thoroughly

More information

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation Cooling and heating systems Static cooling ceiling system SKS-/3 DS 10 E 01.010 Static cooling ceiling system SKS-/3 Main features Preliminary remarks / Applications 3 Main dimensions and materials 3 Construction

More information

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam Halton CBC Active Chilled Beam Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling Well suited for spaces with high cooling loads and low humidity load Ideal

More information

Parameterisable compact fault annunciator with permanent display

Parameterisable compact fault annunciator with permanent display Parameterisable compact fault annunciator with permanent display FSM 10 Drop-flap fault annunciator 31.08.2010 Permanent display even on power failure Compact module for 10 alarms Supply and alarm signal

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL MADE IN THE U.S.A. U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION SERIAL NUMBER The Cookson Company FIREFLY II PLUS Time Delay Release

More information

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION AnaLASER II Detector High-Sensitivity Smoke Detector (HSSD ) F-89-250 FEATURES Air Sampling Smoke Detector for Early Warning Applications Two Versions Available: Standard Detector and Ultra Detector STANDARD

More information

Firetex steel fire shutters

Firetex steel fire shutters Firetex steel fire shutters Firetex; safe, versatile and efficient Firetex shutters are a range of proven fire and smoke control products meeting the requirements of building regulations and life safety

More information

LF-4000 Series Conventional Fire Alarm Control Unit

LF-4000 Series Conventional Fire Alarm Control Unit LF-4000 Series Conventional Fire Alarm Control Unit Features: 1 to 36 Zone Control Panels Control Key Switch Easy Push Button Control Switches Zone Circuit Monitoring for Open and Short Sounder Circuit

More information

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit D-TECT 2 GJD300 Quad PIR Movement Detector Package Contents Package Contains: 1 x D-Tect 2 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare Sliding Curtains 2

More information