Tri-Tech Medical Inc.

Size: px
Start display at page:

Download "Tri-Tech Medical Inc."

Transcription

1 Check Valves with Extensions Project Information Project Number Approval Hinged double disc check valve Removable center section (3 piece design) allows for easy field replacement (no cutting into pipe & re-certification) Available in sizes ¾ to 4 Maximum 300 psig Install in any position Straight through configuration minimizes changes in flow velocity Spring assisted closing ensures valve closes quickly, before reversal of flow Dual 1/8 NPT purge ports Factory brazed extensions allow for fast, lower cost field installation 100% hydrostatically factory tested Cleaned & individually bagged for use with Oxygen in accordance with CGA G-4.1 Materials of Construction Body Brass B16 C Flanges Forged brass B124 C37700 Tubing is type K copper Seal - EPDM Spring Steel AISI 316 Stainless Steel s All check valves shall be Tri-Tech Medical CV-xxxEXT series and must be installed and tested in strict accordance with NFPA 99 standards and or any local codes before use. The check valve shall be of a three-piece in-line repairable design with brazed extensions. Check valves with threaded ends are not acceptable. All valves shall be equipped with type K copper tubing extensions with two 1/8 NPT female gauge/purge ports (one on each side of the valve) to facilitate installation and allow monitoring of the pressure on either side of the check valve. The check valve shall be of the double disc hinged design with EPDM seals. Valves shall be rated at 300 psig working pressure. The check valves shall be factory brazed and cleaned in accordance with CGA G-4.1, capped on both ends, sealed in a heavy duty plastic bag with a desiccant pouch, and include a label stating that the valve has been cleaned for use with oxygen per CGA-G4.1. e5654 r A 12/17/12 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No Sheet 1 of 2

2 Zone Valves in Box Valve size up to 2 Project Information Project Number Approval Meets NFPA 99 requirements Valves may be piped from left to right or right to left Valves are forges brass (not cast) All valves are dual gauge port full port ball valves 3 piece in-line repairable valves Adjustable packing with blow-out proof stem design Accommodate valve sizes from ½ to 2 Valves to have a working pressure of 600 psi (29 in/hg vacuum) All valves cleaned for Oxygen service Plastic insulators to protect from galvanic corrosion Color coded labeling Provided with 1 ½ diameter gauges All zone valve boxes shall be the Tri-Tech Medical Z series and must be installed and tested in strict accordance with NFPA 99 standards and or any other local codes before use. Valves The valves shall be dual gauge port, forged brass, ball-type, with Teflon (TFE) seats and seals. All valves shall be rated at a working pressure of 600 psi (29 in/hg vacuum) and shall be operated by a lever-type handle, requiring only a quarter turn from a fully open position to a fully closed position. Valves shall incorporate an adjustable packing and a blow- out proof stem. Only full port valves having flow rates comparable to equivalent size of pipe shall be used. Valves shall be able to be piped from left to right or right to left. All valves shall be provided with type K copper tubing extensions to facilitate installation. Valves shall be 3 piece in-line repairable type. Each valve assembly shall be supplied cleaned for oxygen service in accordance with current CGA standards. The valve tube ends shall be capped and sealed in a protective container to prevent contamination prior to installation. Gauges shall be 1 ½ diameter for monitoring pressure and vacuum, and shall state: USE NO OIL. Dual scale gauges are not acceptable for U.S.A. installations. A fully color coded label package shall be supplied with each valve box assembly for application by the installer. Shown above Z3G4O4A5V Three valve box with gauges 1 oxygen, 1 medical air, 1 1/4 vacuum Box The valve box shall be 18 gauge sheet steel construction painted to prevent rust. A single box shall house from one to three valves. Boxes may be coupled with other boxes with a part # ZV-801 zone valve box coupler kit. Box shall be supplied with an adjustable plaster flange ½ to 1 1/8 for easy mounting. Window Valve box assembly shall be supplied with a formed steel decorative frame painted white which encloses an easily removable flexible window. The window shall be a smoked translucent flexible plastic with a pull-out ring pre-mounted to the center of the window. The window shall not be replaceable while any valve is in an open position. Window shall be silk screened with the following statement CAUTION: MEDICAL GAS SHUTOFF VALVES. CLOSE ONLY IN EMERGENCY. Shown left ZV-801 Zone Valve Box Coupler Kit Tri-Tech, Avon Commerce Parkway, Avon, Ohio No Rev B 3/8/10 jll

3 Console Slide Bracket Trim Plate Options The Tri-Tech Medical slide brackets are designed to be used with the Tri-Tech Medical XF series medical gas outlets. Anodized aluminum brushed finish Optional trim plates are available in; off-white plastic, offwhite aluminum die cast and pewter aluminum die cast. Two sizes of off-white plastic trim plates available The slide brackets shall be Tri-Tech Medical XF series slide brackets. The slide bracket shall be anodized aluminum with a brushed finish. Slide bracket with cover plate, mounting screws and XC1000-9DCP trim plate shown above. Ordering Information Description Part Number Slide Bracket F Slide Cover Plate AQ Mounting Screws Optional XC Plastic White Trim Plate XC1000-9DC Die Cast White XC1000-9DCP Die Cast Pewter XC Plastic White Trim Plate Size W x L x.400 H W x L x.190 H To place an order or request additional information call, fax or us. e5707rir 03/08/13 Tri-Tech, Avon Commerce Pkwy, Avon, Ohio No E mail address: sales@tri-techmedical.com Web site E Z Backfeed is a registered trademark of Tri-Tech and protected by Patents

4 Sleep Lab Control Panels Project Information Project Number Approval Adjust oxygen to patient without entering the room Durable, easy to clean type 304 stainless steel front Click style flowmeter(s) 0 15 lpm flow Powder coated steel rough in box Inlet & outlet supply tubes provided with demand check s & DISS fittings May be plumbed left to right or right to left s All sleep lab control panels shall be Tri-Tech Medical, Inc. series and must be installed and tested in strict accordance with NFPA 99 standards and or other local codes before use. Rough in box assembly shall be of 14 Ga. steel construction. Box shall be supplied with a plaster flange for easy mounting. Two 1/2 OD Type K copper stubs shall be supplied to facilitate piping to and from the box and to any remote outlets. The sleep lab panel shall include panel mounted click style flowmeter(s) 0-15 lpm flow. Panel shall also include a front loaded CGA DISS gas specific outlet on the inlet and outlet tubes for easy connection/disconnection of the front panel without shutting down medical gases while servicing the panel. SLP-2 Sleep Lab Control Panel Shown NFPA (National Fire Protection Association Pamphlet 99 Health Care Facilities ) compliant. CGA (Compressed Gas Association Pamphlet V- 5 Diameter Index Safety System ) compliant. The gas control panel shall be factory piped and 100% tested. All components shall be panel mounted on a stainless steel, laser etched front panel. Tri-Tech, Avon Commerce Parkway, Avon, Ohio Form # Rev B 03/14/08

5 z Recessed Puritan Style Quick Connect Outlets Project Information Project Number Approval UL Listed to UL 1331 and CSA Z Conforms to NFPA 99 and CGA standards Accepts Puritan style gas specific compatible male adaptors Compensates for variation in wall thicknesses from ½ to 1 ¼ Gas specific indexing Modular design Removable front assembly All outlets are 100% tested for flow and leaks Nameplate color coding per NFPA swivel inlet tube Metal back and nameplate 5 centers Strength of connections provides support for dispensing equipment without the use of additional brackets Made in the U.S.A. The medical gas wall outlets shall be Tri-Tech Medical Puritan compatible quick connect medical gas outlets. The outlets shall be modular singles, and shall incorporate nameplate color-coding in accordance with NFPA 99. The single modular outlets shall be of a design that provides for ganging of rough-in plates in the field to form multiples. The gas services shall be sequentially arranged and located as shown on the plans with a minimum centerline spacing of 5 inches (12.5 cm) between outlets. The medical gas outlets shall be designed so that upon removal of the nameplate assembly, the secondary check valve shall operate automatically to stop the free flow of the positive pressure gas services. There shall be no secondary check for Medical Vacuum or WAGD services. The seal between the nameplate and the rough-in shall be a double O-ring which is serviceable without shutting off the gas service and is capable of supporting 10 2 from the nameplate without leaking. Part Number XP1124 Shown of an inch (1.3 cm to 3 cm). The name of the gas service shall be permanently marked on the outlet bracket and the outlet. The outlet s rough-in supply tube shall be a 7 inch (18 cm) length of 1/2 O.D. copper Type K for all gas services and labeled with the name of the gas service. Medical gas outlets shall be cleaned for oxygen service in accordance with the current Compressed Gas Association (CGA) Pamphlet G-4.1, capped and placed in a protective container for shipment. The outlets shall be installed in strict accordance with manufacturer s instructions, and tested before use in conformance with local and federal codes. MRI compatible models are available (See ordering information chart) and are made with non-ferrous materials. The outlet nameplate shall be permanently color coded with a durable, scratch resistant and protective label. The outlet trim plate shall be durable plastic, attached with the nameplate to the rough-in assembly, and provide automatic plaster adjustment from 1/2 to 1 1/4 e5554r A 08/01/12 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio No Page 1of 2

6 Medical Gas Master Alarms Project Information Project Number Approval The Tri-Tech Master Alarm Panel monitors and displays normal and alarm conditions from up to 64 remote medical gas source signals. Pressure switches and DISS union check valve connectors are sold separately. ETL listed to UL-1069 and CSA-C22.2 No. 205 Complies with NFPA 99. Made in the U.S.A. Self-contained unit designed for ease of installation and service. MCP circuit board available for interface to building management system. Microprocessor controlled Self-diagnostic (test button) and error message display for ease of maintenance. Audio and visual alarm indicators Bright easy to read L.E.D. displays clearly visible in both day and night lighting conditions Visual (green) indication of normal condition Constant display and monitoring of each source alarm signal Individual user programmable remote signal alarm points (NC, NO or disabled) Dry contacts for remote monitoring of all alarm conditions Alarm history display of previous alarm conditions Hinged frame with lanyards for easy accessibility Three year PC board warranty Real time main line gas pressure readout modules available The Master Alarm Panel shall be the Tri-Tech Medical Master Alarm Panel. The panel shall be microprocessor controlled and designed to comply with NFPA 99. The panel shall be 100% digital and shall not require recalibration. The panel shall be able to interface with building management systems with the use of an MCP circuit board. The master alarm panel shall be compatible with the T-Net PC based medical gas information management system. The alarm panel shall be enclosed in a steel box and shall be designed to accept an electrical input range of volts AC hertz. The source voltage shall be stepped down with a self-contained transformer. The panel shall contain audible and visual alarm indicators. The audible alarm may be silenced by pressing the alarm silence button, but the visual alarm indicator can only be cancelled by fault correction. The alarm shall detect and filter out transient signals (less than 0.6 seconds). The alarm shall be capable of displaying alarm history for all possible alarm conditions. (Master alarm shown above is 16 signals part # DU16) Each source signal module shall monitor 16 signals. The alarm shall be capable of monitoring and displaying up to 64 medical gas source signals in increments of 16 source signals. The alarm is modular and may be initially installed as a smaller unit (i.e. 16 signals) and later expanded to (i.e. 32 signals). In addition, each 16 signal Master Alarm Module shall incorporate the following features: Individual user programmable remote signal alarm points to accept NO or NC signals, or may be disabled. Factory preset to accept Normally Closed signals LED indicators (Green) confirms normal status, (Red) indicates abnormal condition Each signal easily labeled and positioned to suit any requirement using self adhesive labels provided with the alarm A set of dry contacts with relay to trigger an optional remote alarm in the event of an alarm condition Tri-Tech, Avon Commerce Parkway, Avon, Ohio Tel or Fax Web-site

7 Z D Series Integra Area Alarm/Zone Valve Project Information Project Number Approval The Tri-Tech Area Alarm Panel digitally displays gas pressure (0.5 psi increments) and monitors and displays normal and alarm conditions for up to 7 medical gases. Transducers are included. Complies with NFPA 99. Made in the U.S.A. ETL Listed to UL-1069 Self-contained unit - Designed for ease of installation and service. Microprocessor controlled Self-diagnostic and error message display for ease of maintenance. Audio and visual alarm indicators Bright easy to read L.E.D. displays clearly visible in both day and night lighting conditions Constant display and monitoring of each gas User programmable high/low set points Dry contacts for remote monitoring of all alarm conditions on each gas module and on the CPU module for the entire panel Alarm history display of previous alarm conditions Easy to read color coded gas modules Hinged frame for easy accessibility Optional interface to the hospital TNET alarm information management system. Three year PC board warranty All valves are dual gauge port full port ball valves 3 piece in-line repairable valves Adjustable packing with blowout proof stem design Accommodate up to 7 valves sizes from ½ to 2 Valves to have a working pressure of 600 psi (29 in/hg vacuum) All valves cleaned for Oxygen service Plastic insulators to protect from galvanic corrosion Color coded labeling Provided with 1 ½ diameter gauges All zone valve boxes shall be the Tri-Tech Medical Z D series and must be installed and tested in strict accordance with NFPA 99 standards and or any other local codes before use. The alarm/ zone valve shall be the Tri-Tech Medical Integra Area Alarm/ Zone Valve Panel. The panel shall be microprocessor controlled and designed to comply with NFPA 99. The panel shall be 100% digital and shall not require re-calibration. The unit shall be enclosed in a steel box and shall be designed to accept an electrical input range of volts AC hertz. The source voltage shall be stepped down with a self-contained transformer. The panel shall contain audible and visual alarm indicators. The audible alarm may be silenced by pressing the alarm silence button, but the visual alarm indicator can only be cancelled by fault correction. The alarm shall detect and filter out transient (less than 0.6 seconds) signals created by R.F.I. The alarm shall be capable of displaying alarm history for all possible alarm conditions. The alarm shall be capable of monitoring and displaying up to 7 gases per alarm panel. Gas modules can be arranged in accordance with the customer s requirements. In addition, each Area Alarm Module shall incorporate the following features: Does not require re-calibration Gas specific sensor with DISS nut & nipple. An error message will be displayed if incorrect sensor or no sensor is attached. User programmable pressure limits (Programmed from factory at 60/40 psig and 12 in Hg) Shall be capable of displaying gas readouts in PSI (in Hg), BAR or kpa, button selected. Gas alarm repeat feature factory set at 10 minutes, adjustable from 1 minute to 240 minutes, or off Valves The valves shall be dual gauge port, cast bronze, ball-type, with Teflon (TFE) seats and seals. All valves shall be rated at a working pressure of 600 psi (29 in/hg vacuum) and shall be operated by a lever-type handle, requiring only a quarter turn from a fully open position to a fully closed position. Valves shall incorporate an adjustable packing and a blow-out proof stem. Only full port valves having flow rates comparable to equivalent size of pipe shall be used. Valves shall be piped from left to right. All valves shall be provided with type K copper tubing extensions to facilitate installation. Valves shall be 3 piece in-line repairable type. Each valve assembly shall be supplied cleaned for oxygen service in accordance with current CGA standards. The valve tube ends shall be capped and sealed in a protective container to prevent contamination prior to installation. Gauges shall be 1 ½ diameter for monitoring pressure and vacuum, and shall state: USE NO OIL. Dual scale gauges are not acceptable for the U.S.A. installations. e5634ra 11/21/12 Tri-Tech, Avon Commerce Pkwy, Avon, Ohio No Tel or Fax Web-site Page 1 of 4

8 Zone Valves In Box with E Z Backfeed Port Valve size to 2 Meets NFPA 99 zone valve box guidelines Forged brass (not cast) Valves include patented E Z Backfeed feature which allows backfeeding of zone without disturbing patients or occupying patient rooms for backfeeding Full port ball valves 3 piece in-line repairable valves Adjustable packing with blow-out proof stem design Accommodate valve sizes from ½ to 2 Valves to have a working pressure of 600 psi (29 in/hg vacuum) All valves cleaned for Oxygen service Available with 1 ½ diameter gauges Plastic insulators to protect from galvanic corrosion E Z Backfeed fitting with Gauge & DISS gas specific demand valves All zone valves shall be Tri-Tech Medical E Z Backfeed series and must be installed and tested in strict accordance with NFPA 99 standards and or any other local codes before use. NFPA Health Care Facilities Handbook (1996 edition), section states: Backfeeding is a way of pressurizing a piped gas system through a station outlet and is opposite to the normal way of pressurizing a system. It is sometimes done when the supply source is interrupted or portions of the system need to be shutdown. This is a very poor practice. Station outlets were designed for flow in an outward direction. With E Z Backfeed valves in a medical facility s zone valve boxes this concern is eliminated. Shown above E Z32O2A2N 3 valve box with gauges 1/2 oxygen, 1/2 medical air, 1/2 nitrous oxide with E Z Backfeed adaptors installed on all valves Gauges shall be 1 ½ diameter for monitoring pressure and vacuum, and shall state: USE NO OIL. Dual scale gauges are not acceptable for U.S.A. installations. Valves The valves shall be forged bronze, ball-type, with Teflon (TFE) seats and seals. All valves shall be rated at a working pressure of 600 psi (29 in/hg vacuum) and shall be operated by a lever-type handle, requiring only a quarter turn from a fully open position to a fully closed position. Valves shall incorporate an adjustable packing and a blow- out proof stem. Only full port valves having flow rates comparable to equivalent size of pipe shall be used. Valves shall be able to be piped from left to right or right to left. Valve(s) shall include DISS gas specific backfeed port. Backfeed port shall allow backfeeding of gas without interruption of gas service. All valves shall be provided with type K copper tubing extensions to facilitate installation. Valves shall be 3 piece in-line repairable type. Each valve assembly shall be supplied cleaned for oxygen service in accordance with current CGA standards. The valve tube ends shall be capped and sealed in a protective container to prevent contamination prior to installation. Box The valve box shall be 18 gauge sheet steel construction painted to prevent rust. A single box shall house from one to three valves. Boxes may be coupled with other boxes with a part # ZV-801 zone valve box coupler kit. Box shall be supplied with a adjustable ½ to 1 1/8 plaster flange for easy mounting. Window Valve box assembly shall be supplied with a formed steel decorative frame painted white which encloses an easily removable flexible window. The window shall be a smoked translucent flexible plastic with a pull-out ring pre-mounted to the center of the window. The window shall not be replaceable while any valve is in an open position. Window shall be silk screened with the following statement CAUTION: MEDICAL GAS SHUTOFF VALVES. CLOSE ONLY IN EMERGENCY. Tri-Tech, Avon Commerce Pkwy, Avon, Ohio Form # Rev B 03/08/10 jll E mail address: sales@tri-techmedical.com Web site E Z Backfeed is a registered trademark of Tri-Tech and protected by Patents

9 E Z Backfeed Retro, E Z Find & E Z Feed Products Tri-Tech Medical patented E Z Backfeed Retro, E Z Find and E Z Feed products allow most existing medical gas valves to be converted to incorporate a DISS gas specific backfeeding port and a DISS gas specific transducer connection. The benefits provided are: the facility has available on line port(s) for backfeeding specific areas of the facility for emergency preparedness and for remodeling. Also, the transducers, which provide/monitor gas line pressures in the zone, are able to be installed in the corresponding zone valve box for easy access for testing and service. Where would you prefer to have your alarm transducers installed? Here or Here Where would you prefer to backfeed your medical gases? Here or Here There is a need for an acceptable place to backfeed medical gases that is safe, easy to find, easy to access. There is a need for an acceptable place to install transducers that is safe to access, easy to find and easy to access. That is what the E Z Backfeed, E Z Feed, and E Z Find products are all about making your hospital safer and your job and the verifier s job easier. Tri-Tech, Avon Commerce Parkway, Avon, Ohio 44011

10 E Z Backfeed Retro, E Z Find & E Z Feed Products E Z Backfeed Retrofit Assembly E Z Find Retrofit Assembly How to Order E Z Products: E Z Backfeed Retrofit Assemblies E Z Find Retrofit Assemblies Oxygen Med Air N2O CO2 N2 Med Vac EZBACK-OXY EZBACK-AIR EZBACK-N2O EZBACK-CO2 EZBACK-N2 EZBACK-VAC EZFIND-OXY EZFIND-AIR EZFIND-N2O EZFIND-CO2 EZFIND-N2 EZFIND-VAC Service Items Retro block Demand valve Gauge 1/8 npt bottom port psig psig psig psig psig Hg 1/8 npt Plug Gas tight cap & chain GC8224 GC8200 GC8200 GC8200 GC8200 GC8200 Tri-Tech, Avon Commerce Pkwy., Avon, Ohio 44011

11 Zone Valves In Box with E Z Backfeed Port Valve size to 2 Meets NFPA 99 zone valve box guidelines Forged brass (not cast) Valves include patented E Z Backfeed feature which allows backfeeding of zone without disturbing patients or occupying patient rooms for backfeeding Full port ball valves 3 piece in-line repairable valves Adjustable packing with blow-out proof stem design Accommodate valve sizes from ½ to 2 Valves to have a working pressure of 600 psi (29 in/hg vacuum) All valves cleaned for Oxygen service Available with 1 ½ diameter gauges Plastic insulators to protect from galvanic corrosion E Z Backfeed fitting with Gauge & DISS gas specific demand valves All zone valves shall be Tri-Tech Medical E Z Backfeed series and must be installed and tested in strict accordance with NFPA 99 standards and or any other local codes before use. NFPA Health Care Facilities Handbook (1996 edition), section states: Backfeeding is a way of pressurizing a piped gas system through a station outlet and is opposite to the normal way of pressurizing a system. It is sometimes done when the supply source is interrupted or portions of the system need to be shutdown. This is a very poor practice. Station outlets were designed for flow in an outward direction. With E Z Backfeed valves in a medical facility s zone valve boxes this concern is eliminated. Shown above E Z32O2A2N 3 valve box with gauges 1/2 oxygen, 1/2 medical air, 1/2 nitrous oxide with E Z Backfeed adaptors installed on all valves Gauges shall be 1 ½ diameter for monitoring pressure and vacuum, and shall state: USE NO OIL. Dual scale gauges are not acceptable for U.S.A. installations. Valves The valves shall be forged bronze, ball-type, with Teflon (TFE) seats and seals. All valves shall be rated at a working pressure of 600 psi (29 in/hg vacuum) and shall be operated by a lever-type handle, requiring only a quarter turn from a fully open position to a fully closed position. Valves shall incorporate an adjustable packing and a blow- out proof stem. Only full port valves having flow rates comparable to equivalent size of pipe shall be used. Valves shall be able to be piped from left to right or right to left. Valve(s) shall include DISS gas specific backfeed port. Backfeed port shall allow backfeeding of gas without interruption of gas service. All valves shall be provided with type K copper tubing extensions to facilitate installation. Valves shall be 3 piece in-line repairable type. Each valve assembly shall be supplied cleaned for oxygen service in accordance with current CGA standards. The valve tube ends shall be capped and sealed in a protective container to prevent contamination prior to installation. Box The valve box shall be 18 gauge sheet steel construction painted to prevent rust. A single box shall house from one to three valves. Boxes may be coupled with other boxes with a part # ZV-801 zone valve box coupler kit. Box shall be supplied with a adjustable ½ to 1 1/8 plaster flange for easy mounting. Window Valve box assembly shall be supplied with a formed steel decorative frame painted white which encloses an easily removable flexible window. The window shall be a smoked translucent flexible plastic with a pull-out ring pre-mounted to the center of the window. The window shall not be replaceable while any valve is in an open position. Window shall be silk screened with the following statement CAUTION: MEDICAL GAS SHUTOFF VALVES. CLOSE ONLY IN EMERGENCY. Tri-Tech, Avon Commerce Pkwy, Avon, Ohio Form # Rev B 03/08/10 jll E mail address: sales@tri-techmedical.com Web site E Z Backfeed is a registered trademark of Tri-Tech and protected by Patents

12 Manufacturer of Medical Gas Pipeline Equipment Emergency Oxygen Inlet Box (Recessed) The EOI-series Tri-Tech Medical Emergency Inlet Box provides an inlet for connection a temporary auxiliary source of oxygen to the oxygen pipeline system for emergency or maintenance situations as recommended by NFPA 99. Made in the U.S.A. Designed in accordance with NFPA 99. Rugged powder coated steel NEMA 4 weather-tight enclosure with padlock staples to prevent tampering or unauthorized access 1 NPTF oxygen inlet - supports high flow requirements (other sizes available upon request) Entire assembly is cleaned for oxygen service and capped. Available with back outlet connection only Includes a 75 psig safety relief valve. Includes a 1 check valve brazed into box s The Emergency Oxygen Inlet Box shall be Tri- Tech Medical Emergency Oxygen Inlet Box. The Emergency Inlet Box shall provide an inlet for connection a temporary auxiliary source of oxygen to the oxygen pipeline system for emergency or maintenance situations as recommended by NFPA 99. The Emergency Inlet Box shall consist of a ball valve, pressure gauge and a NPTF (plugged) connection housed in a tamper resistant, weather tight, maintenance free, powder coated steel enclosure. The enclosure shall be labeled Emergency Low Pressure Gaseous Oxygen Inlet, and include a padlock staple to prevent tampering or unauthorized access. The Emergency Inlet Box should be connected at a point downstream of the main supply line shutoff valve. A fast acting check valve shall be included in the Emergency Inlet Box as recommended by NFPA 99. The check valve shall have a cast bronze body and straight - through design for minimum pressure drop. A 75 psig relief valve shall be included in the Emergency Inlet Box as recommended by NFPA 99. The relief valve shall have a brass body, single seat design, and be cleaned for oxygen. The relief valve automatically opens to relieve or vent pressures greater than 75 psig to atmosphere and will automatically reseat to provide a bubble tight seal after the pressure drops below 75 psig. Tri-Tech, Avon Commerce Pkwy, Avon, Ohio 44011

13 Manufacturer of Medical Gas Piping Equipment Emergency Oxygen Inlet Box Emergency Oxygen Inlet Box (Model EOI-100-Back shown above) : Designed in accordance with NFPA 99. Rugged fiberglass NEMA 4 weather-tight enclosure with padlock staple to prevent tampering or unauthorized access (16 H x 14 W x 6 D). 1 NPTF oxygen inlet supports high flow requirements (larger sizes available upon request) Entire assembly is cleaned for oxygen service and capped. Available with; side, bottom or back connection point. Includes a ¾ 75 psig safety relief valve. The EOI-100 Tri-Tech Medical Emergency Inlet Box provides an inlet for connection a temporary auxiliary source of oxygen to the oxygen pipeline system for emergency or maintenance situations as recommended by NFPA 99. The EOI-100 Tri-Tech Medical Emergency Inlet Box consists of a 1 (25mm) ball valve, pressure gauge and a 1 NPTF (plugged) connection housed in a tamper resistant, weathertight, maintenance free, fiberglass enclosure. The enclosure is labeled Emergency Low Pressure Gaseous Oxygen Inlet, and includes a padlock staple to prevent tampering or unauthorized access. The EOI-100 Tri-Tech Medical Emergency Inlet Box should be connected at a point downstream of the main supply line shutoff valve. A fast acting 1 check valve is included in the EOI-100 Tri-Tech Medical Emergency Inlet Box as recommended by NFPA 99. The check valve has a cast bronze body and straight through design for minimum pressure drop. A 75 psig relief valve is included in the EOI-100 Tri-Tech Medical Emergency Inlet Box as recommended by NFPA 99. The relief valve has a brass body, single seat design, and is cleaned for oxygen. The relief valve automatically opens to relieve or vent pressures greater than 75 psig to atmosphere and will automatically reseat to provide a bubble tight seal after the pressure drops below 75 psig. Tri-Tech, Avon Commerce Pkwy., Avon, Ohio /15/10 jll

14 Refrigerated Medical Air Dryer System Project Information Project Number Approval Stack-mounted Dual Refrigerated Medical Air Dryers can be packaged and piped with a dual line regulated medical air filtration system. Allows for easy mounting and installation of Carbon Monoxide and Dew Point Monitor, making for a complete NFPA compliant Medical Air Treatment System. Meets all NFPA 99 requirements Modular heavy duty steel frame Brazed / Nitrogen purged joint connections s Stack Mounted Dual Refrigerated Medical Air Dryers: 9 options to choose from, offering a wide range of flow capacities from 5 to 150 scfm at 100 psig per dryer. Each refrigerated dryer includes 3-valve bypass, air to air heat exchangers, moisture separators, on/off switch, and suction pressure gauge. Constant dew point of 38º F at 100 psig. Standard electrical configuration is 1 phase, 60 Hertz, 115 / 208 / 230 Volt. Optional Medical Filtration System: Dual line fully regulated system, completely prepiped with bypass valving, and constructed of noncorrosive material. Unit includes two pressure regulators, ASME safety relief valves, differential pressure switch, and two complete banks of three filters each. Each bank of filters includes an activated carbon filter, a.5 micron filter, and a.01 micron filter Ordering Information Stackmounted Dual Refrigerated Medical Air Dryers Part Number 100 psig Inlet nptf connection Outlet nptf connection MDR /8 ½ MDR /8 ½ MDR /8 ½ MDR ½ ½ MDR ½ ½ MDR ½ MDR MDR MDR ¼ Optional Medical Filtration System: Part Number 125 psig Inlet/Outlet nptf port size MFP ½ MFP ½ MFP ¾ MFP MFP MFP-220-3A ¼ Tri-Tech, Avon Commerce Parkway, Avon, Ohio 44011

15 Exposed Allied/Chemetron Style Surface Mount Outlets Project Information Project Number Approval ETL Listed to UL 1331 and CSA Z Conforms to NFPA 99 and CGA standards Accepts Allied Chemetron gas specific compatible male adaptors Surface mount installation Gas specific indexing All outlets are 100% tested for flow and leaks Nameplate color coding per NFPA 99 Made in the U.S.A. The medical gas wall outlets shall be Tri-Tech Medical quick connect medical gas outlets XQ21xx series. The outlets shall be exposed surface mounted singles, and shall incorporate nameplate color-coding in accordance with NFPA 99. The medical gas outlets shall be designed so that upon removal of the nameplate assembly, the secondary check valve shall operate automatically to stop the free flow of the positive pressure gas services. There shall be no secondary check for Medical Vacuum or WAGD services. The seal between the nameplate and the rough-in shall be a double O-ring which is serviceable without shutting off the gas service. The medical gas outlet shall be capable of supporting 10 2 from the nameplate without leaking. The outlet nameplate shall be permanently color-coded with a durable scratch resistant and protective label. The outlet surface-mount housing shall be durable scratch resistant plastic. The outlet nameplate and housing shall be attached to the outlet bracket. The name of the gas service shall be permanently embossed on the outlet bracket and the chrome plated brass outlet body. The outlet s rough-in supply tube shall be a 7 inch (18 cm) length of 1/2 OD copper Type K, for all gas services and labeled with the name of the gas service. Part number AQ2124 shown Medical gas outlets shall be cleaned for oxygen service in accordance with the current Compressed Gas Association (CGA) Pamphlet G-4.1, capped and placed in a protective container for shipment. The outlets shall be installed in strict accordance with manufacturer s instructions, and tested before use in conformance with local and federal codes. e5295ra Tri-Tech, Avon Commerce Parkway, Avon, Ohio /08/11

EZT Series Integra Med Touch Area Alarm & Zone Valve Box with EZ Backfeed

EZT Series Integra Med Touch Area Alarm & Zone Valve Box with EZ Backfeed Submittal Data Sheet Features The Powerex Med Touch area alarm zone valve panel digitally displays gas pressure (1 psi increments) and provides alarm conditions as required by the latest edition of NFPA

More information

Med Touch Combination Alarm Conversion Kits

Med Touch Combination Alarm Conversion Kits Submittal Data Sheet Features The Powerex Combination Alarm Panel conversion kits are designed to upgrade or retro-fit existing panels produced by several major brands. The conversion kit replaces all

More information

Tri-Tech Medical Inc.

Tri-Tech Medical Inc. Submittal Data Sheet Project Information Project Number Approval Features The Tri-Tech Area and Master Alarm Panel digitally displays gas pressure (1 psi increments) monitors and displays normal and alarm

More information

Tri-Tech Medical Inc.

Tri-Tech Medical Inc. Submittal Data Sheet Project Information Project Number Approval Features The Master Alarm Panel conversion kits are designed to upgrade or retro-fit existing panels produced by several major brands. The

More information

Med Touch Master Alarm

Med Touch Master Alarm Submittal Data Sheet Features The Powerex Med Touch Master Alarm Panel monitors and displays normal and alarm conditions from up to 128 remote medical gas source signals and provides alarm conditions as

More information

Installation & Operating Instructions for Med Touch Series Area, Master & Combination Alarm Systems

Installation & Operating Instructions for Med Touch Series Area, Master & Combination Alarm Systems Manufacturer of Medical Gas Pipeline Equipment Installation & Operating Instructions for Med Touch Series Area, Master & Combination Alarm Systems Master Alarm Area Alarm Andersen Medical Gas 12 Place

More information

Installation & Operating Instructions for ZT and EZT Integra Touch Series Area Alarm Zone Valve Box Systems

Installation & Operating Instructions for ZT and EZT Integra Touch Series Area Alarm Zone Valve Box Systems Manufacturer of Medical Gas Pipeline Equipment Installation & Operating Instructions for ZT and EZT Integra Touch Series Area Alarm Zone Valve Box Systems e6565rc 05/11/18, 35401 Avon Commerce Pkwy., Avon,

More information

Installation Instructions for Med-Touch Series LCD Medical Gas Area, Master & Combination Alarms Conversion Kits

Installation Instructions for Med-Touch Series LCD Medical Gas Area, Master & Combination Alarms Conversion Kits Manufacturer of Medical Gas Pipeline Equipment Installation Instructions for Med-Touch Series LCD Medical Gas Area, Master & Combination Alarms Conversion Kits Master Alarm Conversion Combination Alarm

More information

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No. SECTION 22 63 13 GAS PIPING FOR LABORATORY AND HEALTHCARE FACILITIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Pipeline. Medical Gas Pipeline Products

Pipeline. Medical Gas Pipeline Products Pipeline Medical Gas Pipeline Products w w w. a m i c o. c o m The Amico Group Manufactures the Building Blocks of the Hospital Architectural Beds Lights Medical Storage Accessories Patient Care Diagnostics

More information

Installation & Operating Instructions for Integrated Series Area Alarm Zone Valve Box Systems

Installation & Operating Instructions for Integrated Series Area Alarm Zone Valve Box Systems Manufacturer of Medical Gas Pipeline Equipment Installation & Operating Instructions for Integrated Series Area Alarm Zone Valve Box Systems e5536rir 6/15/12 Tri-Tech, 35401 Avon Commerce Pkwy., Avon,

More information

DC Series Area, Master and Combination Alarm Systems Opreator s Manual

DC Series Area, Master and Combination Alarm Systems Opreator s Manual Opreator s Manual Ver. 2012 - Rev. 1004 Class 1 Inc. design manufacture installation service world class innovation Call us for your next project. Introduction The Tri-Tech Medical gas alarm system monitors

More information

Pipeline. Medical Gas Pipeline Products

Pipeline. Medical Gas Pipeline Products Pipeline Medical Gas Pipeline Products The Amico Group Manufactures the Building Blocks of the Hospital Architectural Beds Lights Interiors Accessories Furniture Diagnostic Clinical - OR Suction & Oxygen

More information

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings. SECTION 15481 COMPRESSED AIR SYSTEM PART 1 - GENERAL 1.1 SECTION INCLUDES A. Pipe and pipe fittings, including valves, unions and couplings. B. Air compressor. C. After cooler. D. Refrigerated air dryer.

More information

DUKE UNIVERSITY CONSTRUCTION STANDARDS

DUKE UNIVERSITY CONSTRUCTION STANDARDS 1 22 60 00 Gas and Vacuum Systems for Laboratory & Healthcare Facilities 1. General A. Furnish and test the following systems: 1. Oxygen (O2) 2. Vacuum (Vac) 3. Medical/clinical compressed air (MA) 4.

More information

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls Specification General The Powerex Laboratory Scroll Enclosed Air Compressor System is designed to provide clean, dry air for

More information

Flow Control for Fire Protection

Flow Control for Fire Protection Flow Control for Fire Protection Valve Solutions From An Industry Leader AmesFireWater.com Count on the Fire Protection Leader for Reliable Flow Control Solutions Ames provides a range of high-quality

More information

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS SECTION 22 20 00 LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements",

More information

Installation, Operation, and Maintenance Instructions

Installation, Operation, and Maintenance Instructions Installation, Operation, and Maintenance Instructions MEGA 2 Medical Electronic Gas Alarm Andersen Medical Gas 12 Place Lafitte Madisonville, LA 70447 http://www.themedicalgas.com 1-866-288-3783 MAN 01-027

More information

Flow Control for Fire Protection

Flow Control for Fire Protection Flow Control for Fire Protection Valve Solutions From An Industry Leader AmesFireWater.com Count on the Fire Protection Leader for Reliable Flow Control Solutions Ames provides a range of high-quality

More information

Installation & Operating Instructions for Area, Master & Combination Alarm Systems

Installation & Operating Instructions for Area, Master & Combination Alarm Systems Manufacturer of Medical Gas Pipeline Equipment Installation & Operating Instructions for Area, Master & Combination Alarm Systems Andersen Medical Gas 12 Place Lafitte Madisonville, LA 70447 http://www.themedicalgas.com

More information

Portable C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

Portable C1N Series - Light Industrial Heaters Tankless Water Heating Solutions Heavy duty industrial cart options simplify moving heater to various locations 18-25 kw (61,4000-85,300 BTUs) Low flow activation options at 0.25 and 0.50 GPM (1.0 and 1.9 LPM) Certified Lead-Free Design

More information

Alert-3 LCD Alarm v2.0

Alert-3 LCD Alarm v2.0 Operating & Maintenance Manual Alert-3 LCD Alarm v2.0 1ST FLOOR ROOM 12 2ND FLOOR ROOM 25 3RD FLOOR ROOM 37 MAINTEN EXT 302 4TH FLOOR ROOM 47 5TH FLOOR ROOM 58 w w w. a m i c o. c o m Contents User Responsibility

More information

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES SECTION 23 23 00 REFRIGERANT PIPING AND SPECIALITIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Refrigerant piping. 2. Unions, flanges, and couplings. 3. Pipe hangers and supports. 4. Refrigerant

More information

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions Pre-assembled skid system Back-to-Back heater models, SNA & SNAR High Flow Demand Safety Shower Applications 216-288 kw (737,000-983,000 BTUs) Temperature overshoot purge system NEMA 4 enclosure standard

More information

TECHNICAL. Series 18. Pump Packages

TECHNICAL. Series 18. Pump Packages TECHNICAL S Y S T E M S Series 18 Pump Packages Series 18 Pump Packages Standard Features Close-coupled, end-suction, centrifugal pumps Mounted and wired pump starters Hand-Off-Auto switch for each pump

More information

SECTION DOMESTIC WATER PIPING SPECIALTIES

SECTION DOMESTIC WATER PIPING SPECIALTIES SECTION 22 11 19 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions 18-25 kw (61,4000-85,300 BTUs) Low flow activation options at 0.25 and 0.50 GPM (1.0 and 1.9 LPM) Certified Lead-Free Design Variable Temp Heat Exchanger Pressure Drop Advantage NEMA 4 enclosure standard

More information

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions Portable C2N Series - Light Industrial Heaters Heavy duty industrial cart options simplify moving heater to various locations 36-50 kw (122,800-170,600 BTUs) Variable Temp Heat Exchanger Pressure Drop

More information

Centro-Matic Automated Lubrication Systems System Controls

Centro-Matic Automated Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications 36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Certified Lead-Free Design NEMA 4 enclosure standard ASME and NB Certified options available Pressure Drop Advantage Dual Flow Activation

More information

1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - "Systems and Equipment.

1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - Systems and Equipment. Page 238239-1 SECTION 238239 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Technical Specification

Technical Specification Technical Specification Surface Area Valve Service Unit Module Semi Flush Area Valve Service Unit Module Product Description The CPX AVSU Module is used in conjunction with area valve service units (AVSU).

More information

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories. Page 238219-1 SECTION 238219 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Core Lab Consolidation Memorial Hermann Southwest SECTION MEDICAL PIPING AND PIPE LINE COMPONENTS

Core Lab Consolidation Memorial Hermann Southwest SECTION MEDICAL PIPING AND PIPE LINE COMPONENTS PART 1 - GENERAL 1.1 WORK INCLUDED SECTION 15 4 80 A. Furnish and test the following systems: 1. Oxygen (O2). 2. Vacuum (V). 3. Nitrous oxide (N2O). 4. Medical/clinical compressed air. (A) 5. Nitrogen

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

Installation and Maintenance Manual. Alarm Valve Combo Unit Alert-1 v1.6

Installation and Maintenance Manual. Alarm Valve Combo Unit Alert-1 v1.6 Installation and Maintenance Manual Alarm Valve Combo Unit Alert-1 v1.6 Table of Contents User Responsibility 4 Introduction 5 Features 5 Installation of Valve Boxes 6 Maintenance and Annual Test 7 Description

More information

Series 20 Dual Check Backflow Preventers

Series 20 Dual Check Backflow Preventers Series 20 Dual Check Backflow Preventers Excellence Matters Specify It! A Division of Watts Regulator Company 427 North Market Blvd Suite #9 Sacramento, CA 9584 Phone: 96-928-02 Fax: 96-928-9 www.amesfirewater.com

More information

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual DRRRRDRY-PAK Instruction and Installation Manual IB-160 Rev. B P/N 36595 Registered by UL to ISO 9001 DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual INSTALLATION: Models DS0-00-000 through

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

Enclosed Scroll Air Compressor System SES 3-5 HP

Enclosed Scroll Air Compressor System SES 3-5 HP Enclosed Scroll Air Compressor SES 3-5 HP Specification General The Powerex Enclosed Scroll Air Compressor unit is designed to provide clean, dry air for industrial applications where the quality of the

More information

Laboratory Enclosed Rotary Screw Air Compressor System with Air Treatment Center Package

Laboratory Enclosed Rotary Screw Air Compressor System with Air Treatment Center Package System with Air Treatment Center Package Specification General The Powerex Laboratory Screw Compressor Enclosure package shall include multiple oil-free rotary screw air compressors modules and associated

More information

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions 36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Certified Lead-Free Design NEMA 4 enclosure standard ASME and NB Certified options available New & Improved Pressure Drop Advantage Dual

More information

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions Portable CNA-Series - Large Industrial Heaters Heavy duty industrial cart options simplify moving heater to various locations 36-72 kw (122,800-245,600 BTUs) Certified Lead-Free Design New & Improved Pressure

More information

SN Series - Safety Shower Heaters Tankless Water Heating Solutions

SN Series - Safety Shower Heaters Tankless Water Heating Solutions 36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Lead-Free Design NEMA 4 enclosure standard ETL and cetl certified to UL and CSA Standards Liquid-Cooled Solid State Relays Internal fusing

More information

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions 36-144 kw (122,800-491,300 BTUs) Certified Lead-Free Design New & Improved Pressure Drop Advantage Variable Temp Heat Exchanger NEMA 4 enclosure standard Independent Safeties ETL and cetl certified to

More information

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6 DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6 1.1. REFERENCE STANDARDS 1.2. GENERAL 1.1.1. The units shall be listed by Electrical Testing Laboratories (ETL) and bear the ETL label. 1.1.2.

More information

ECS Protector Nitrogen Generator PGEN-40FK/PGEN-50FK/PGEN-60FK PGEN-40M/PGEN-50M/PGEN-60M

ECS Protector Nitrogen Generator PGEN-40FK/PGEN-50FK/PGEN-60FK PGEN-40M/PGEN-50M/PGEN-60M ECS Protector PGEN-40/PGEN-50/PGEN-60 (PGEN-40E/PGEN-50E/PGEN-60E) For use under U.S. Patents 8,720,591, 9,144,700 and 9,186,533 Specifications Dimensions (cabinet): Dimensions (incl. bypass): Weight:

More information

Integra Med Touch Series LCD Area Alarm & Zone Valve Box Systems

Integra Med Touch Series LCD Area Alarm & Zone Valve Box Systems Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information.

More information

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F 34-200 SERIES HYDRONIC TEMPERING VALVES The Apollo Model TV (34-200 Series) thermostatic mixing valve provides non-asse extension of water heater capacity and hot water temperature control in hydronic

More information

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW MODEL V Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW Features Industrial Grade Construction Stainless steel pressure vessel provides maximum service

More information

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page 150-3,000 scfm AEHD Series Desiccant Air Dryers AEHD Series Externally Heated Desiccant Air Dryer 150-3,000 scfm Front Page 1 AEHD Series Heated Dryer Externally Heated Desiccant Dryer 150-3,000 scfm Since

More information

TABLE 1 Electrical Specifications. Phase

TABLE 1 Electrical Specifications. Phase CHRONOMITE HIGH CAPACITY INSTANT-TEMP WATER HEATERS INSTALLATION AND OPERATION INSTRUCTIONS (208-240V 3 Φ Models) (Before installation, compare electrical requirements needed for the model of heater selected)

More information

T a b l e o f C o n t e n t s

T a b l e o f C o n t e n t s w w w. g e n t e c h e a l t h c a r e. c o m M E D I C A L M O N I T O R I N G, A L A R M A N D C O N T R O L S Y S T E M S I n t e r n a t i o n a l E d i t i o n Technology for a Better Future Company

More information

VMUS-4 Ozone Generator

VMUS-4 Ozone Generator VMUS-4 Ozone Generator Installation and Operation Manual pg. 1 Cautions, Warnings and Hazards Refer to the manual of the ozone generating system first, to assure proper location of all ozone equipment.

More information

Used Fluid Handling Portable Used Oil Gravity Drains

Used Fluid Handling Portable Used Oil Gravity Drains Portable Used Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)

More information

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Specification General The Powerex Laboratory Open Scroll Air Compressor System is designed to provide clean, dry air for applications

More information

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm Operating & Maintenance Manual Alert-4 Ethernet LCD Master Alarm w w w. a m i c o. c o m Contents User Responsibility 4 Introduction 4 Features 5 Description of the Alarm 5 Shipment Details 5 The Alarm

More information

CFH Series High Efficiency Filters

CFH Series High Efficiency Filters CFH Series High Efficiency Filters Intelligent Air Technology Save energy, dollars & protect your air system The Compressed Air Challenge, a government/ industry sponsored energy savings awareness program,

More information

Using the Model 1500 Portable Chilled Mirror Hygrometer

Using the Model 1500 Portable Chilled Mirror Hygrometer APPLICATION NOTE 2016_0120 MODEL 1500 Rev C Using the Model 1500 Portable Chilled Mirror Hygrometer The Model 1500 is a portable, multi-function, optical chilled mirror hygrometer designed to accurately

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters. Section 15 _ Energy Recovery Air Handling System Part 1: GENERAL 1.1 Section Includes: A. Energy Recovery Air Handler B. Controls (most by Others) C. Equipment Schedule 1.2 Related Sections: A. Section

More information

Automatic Temperature Controller (ATC)

Automatic Temperature Controller (ATC) NEW FROM APOLLO...THE FIRST MULTIPLE-FIXTURE HI-LO MIXING VALVE THAT MEETS ASSE 1017 AND THE NEW ASSE 1069 STANDARD Only Apollo offers fast delivery on the first water temperature mixing assembly to meet

More information

SECTION METERS AND GAGES FOR PLUMBING PIPING

SECTION METERS AND GAGES FOR PLUMBING PIPING SECTION 220519 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

ECS Protector Nitrogen Generator. ECS Protector Nitrogen Generator PGEN-30. Specifications

ECS Protector Nitrogen Generator. ECS Protector Nitrogen Generator PGEN-30. Specifications ECS Protector PGEN-30 Specifications Dimensions (cabinet): 24 (W) X 12 (D) X 53 (H) Width (incl. bypass): 33 Weight: Power Supply: Power Consumption: Gas Connections: Drain Connection: 152 lbs 120v/1 phase/60hz

More information

TABLE 1 Electrical Specifications

TABLE 1 Electrical Specifications CHRONOMITE HIGH CAPACITY INSTANT-TEMP WATER HEATERS INSTALLATION AND OPERATION INSTRUCTIONS (208-240V Models) (Before installation, compare electrical requirements needed for the model of heater selected)

More information

Refrigerant Valves/Accessories

Refrigerant Valves/Accessories Inline Check Valves Compact in-line (non-return) check valves for closure upon pressure reversals. Low Pressure Drop Mounts In Any Position Stainless Steel Disc Safe Working Pressure 400psig Operating

More information

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14 Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14 GENERAL The Powerex Laboratory Open Scroll Air Compressor System is designed to provide clean, dry air for applications

More information

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12 Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12 GENERAL The Powerex oil-less tank mounted system is designed to provide clean, dry air for industrial applications where the

More information

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN DIVISION 21 - FIRE SUPPRESSION (REFER TO SECTION 23 05 00 FOR BASIC FIRE SUPPRESSION REQUIREMENTS) 21 05 00 Common Work Results for Fire Suppression 21 13 13 Wet-Pipe Sprinkler Systems END OF SECTION FIRE

More information

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾ CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.

More information

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr) D twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-1,300 Nm3/hr) D D D twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-1,300 Nm 3 /hr) Leading

More information

TECHNICAL DATA. Wet 26a. February 22, 2009

TECHNICAL DATA. Wet 26a. February 22, 2009 February 22, 2009 Wet 26a 1. DESCRIPTION The Viking Alarm Check Valve serves as a check valve by trapping pressurized water above the clapper and preventing reverse flow from sprinkler piping. The valve

More information

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model BWXP OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER Electric Heater Company Base Model "BWXP" HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)

More information

PART NO. COMBUSTION AIR CAP

PART NO. COMBUSTION AIR CAP ACCESSORIES FOR SPACE-RAY TUBE HEATERS VENT CAP --- Sidewall or Roof Unique design prevents back drafts and assists in drawing off and exhausting the products of combustion regardless of wind direction

More information

C1N & C2N SERIES Fluid heating for light industrial applications

C1N & C2N SERIES Fluid heating for light industrial applications Keltech Electric Tankless Water Heaters C1N & CN SERIES Fluid heating for light industrial applications Contents Keltech Electric Tankless Water Heaters C1N & CN Series Overview Standard Features 6 Optional

More information

water source / fan coils

water source / fan coils MANUAL BALL ALE W/MEMORY STOP (BMS) An adjustable stop position lever to limit travel of the On/Off handle. This allows the ball valve to be closed, and returned to the balance setting position without

More information

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE. Temperature Control Units Water & Oil 0-00 F Portable Chillers 0 - F Central Chillers Packages & Modules 0 - F Pump Tank Stations Chilled or Tower Water 00-0 gallons Cooling Tower Cells 4-40 tons Filters

More information

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS 230500 HVAC BASIC MATERIAL AND METHODS PART 1 GENERAL 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS A. Section 230000 Basic HVAC Requirements B. Section 230523 Valves C. Section 230510 Chilled

More information

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Pipe and Pipe Fittings. B. Air compressor. C. Air receiver and accessories. D. Aftercooler. E. Refrigerated air dryer. F. Pressure reducing station. 1.02 RELATED

More information

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. This section outlines the requirements for the nitrogen-generating sprinkler corrosion inhibiting system. The work

More information

Ohio Medical is the only name you need to know for your medical suction and oxygen therapy and medgas equipment needs.

Ohio Medical is the only name you need to know for your medical suction and oxygen therapy and medgas equipment needs. Ohio Medical Corporation has been the leading supplier of Healthcair medical air and vacuum pumping systems, Ohio Medical Corporation and Amvex medical suction regulators, Ohio Medical and Amvex air and

More information

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL Essex County College - West Essex Campus Addition And Renovations dib # 54292 / 11-14 SECTION 232116 - HYDRONIC PIPING SPECIALTIES PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions

More information

Scroll Medical Air Compressor with Premium NFPA Control Panel

Scroll Medical Air Compressor with Premium NFPA Control Panel Scroll Medical Air Compressor with Premium NFPA Control Panel General The Powerex Skid Mount Scroll Medical Air System is designed to provide medical breathing air for hospital and medical institutions.

More information

WAL-RICH CORPORATION SINCE 1950

WAL-RICH CORPORATION SINCE 1950 HOSES 3/8 ID DOUBLE FEMALE HOSE - BAGGED BAGGED# SIZE Box 0802002 3/4 FHT x 4' 1 25 0802004 3/4 FHT x 5' 1 25 0802006 3/4 FHT x 6' 1 25 0802008 3/4 FHT x 8' 1 25 0802010 3/4 FHT x 10' 1 25 0802012 3/4

More information

AS950 REFRIGERATED SAMPLERS

AS950 REFRIGERATED SAMPLERS AS950 REFRIGERATED SAMPLERS Applications Wastewater Collections Industrial Pretreatment Environmental Monitoring Stormwater Sampling has never been this easy. The AS950 Refrigerated Sampler makes programming,

More information

WAL-RICH CORPORATION SINCE 1950

WAL-RICH CORPORATION SINCE 1950 STEAM SPECIALTIES ANGLE STEAM RADIATOR VALVES 0408102 1/2 1 10 0408104 3/4 1 6 0408002 1" 1 4 0408004 1 1/4" 1 2 0408006 1 1/2 1 2 - Brass - Imported STRAIGHT STEAM RADIATOR GATE VALVES 0409002 1" 1 4

More information

S19361F - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

S19361F - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions Pre-assembled, freeze-protected safety fixture and SNA heater skid system Bradley Heat Trace S19-300 with SpinTec 54-144 kw (491,300 BTUs) Molded Duragrate and integrated shower pan Temperature overshoot

More information

CLE SERIES Fluid heating for emergency eyewash stations

CLE SERIES Fluid heating for emergency eyewash stations Keltech Electric Tankless Water Heaters CLE SERIES Fluid heating for emergency eyewash stations Contents 2 Keltech Electric Tankless Water Heaters 3 CLE Series Overview 4 Standard Features 6 Optional Features

More information

Alert-3 LCD Alarm v2.5

Alert-3 LCD Alarm v2.5 Operating & Maintenance Manual Alert-3 LCD Alarm v2.5 1ST FLOOR ROOM 12 2ND FLOOR ROOM 25 3RD FLOOR ROOM 37 MAINTEN EXT 302 4TH FLOOR ROOM 47 5TH FLOOR ROOM 58 Contents User Responsibility 4 Introduction

More information

AFUE 95% Heating Input 50,000 to 200,000 Btuh

AFUE 95% Heating Input 50,000 to 200,000 Btuh PRODUCT SPECIFICATIONS WATER HEATERS / BOILERS GWM-IE Gas-Fired, Modulating, Condensing, Wall Hung Hot Water Boiler Bulletin No. 210650 March 2018 Supersedes December 2015 AFUE 95% Heating Input 50,000

More information

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY SECTION 22 11 23.13 DOMESTIC WATER PRESSURE BOOSTING PART 1 - GENERAL 1.1 SUMMARY A. Where utility water pressure cannot adequately meet the pressure requirements of the domestic water systems and where

More information

A. This Section includes the following domestic water piping specialties:

A. This Section includes the following domestic water piping specialties: SECTION 221119 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

HTU-500 Ozone Generator

HTU-500 Ozone Generator HTU-500 Ozone Generator Installation and Operation Manual pg. 1 Cautions, Warnings and Hazards Refer to the manual of the ozone generating system first, to assure proper location of all ozone equipment.

More information

Used Fluid Handling Portable Used-Oil Gravity Drains

Used Fluid Handling Portable Used-Oil Gravity Drains Portable Used-Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)

More information

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw SEMI-INSTANTANEOUS ENERGY: STEAM TO WATER U-TUBE SINGLE-WALL & DOUBLE-WALL HEAT EXCHANGERS FLOOR DRAIN Typical Construction Figure 34-1 FLOOR DRAIN 1. U-tube

More information

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton G Series ENCASED/UNCASED AIR COILS Geothermal/Water Source Heat Pumps R-410A Refrigerant 2- Ton Dimensional Data G Series Air Coils Installation ti Manual Installation Information Maintenance IM1018AG1

More information

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package

More information

RNC Series SCFM Global Air Treatment

RNC Series SCFM Global Air Treatment RNC Series 10 3000 SCFM Global Air Treatment 2 Durability Delivered Air Treatment Systems RNC Series refrigerated air dryers are engineered to benefit you today and tomorrow from the tradition of durability

More information

DESIGN STANDARDS SECTION 15600

DESIGN STANDARDS SECTION 15600 PART 1 - GENERAL 1.1 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.2 General requirements: A. Reciprocating

More information