Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring

Size: px
Start display at page:

Download "Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring"

Transcription

1 F U L L - L I N E P R O D U C T G U I D E Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring

2 At System Sensor, innovation is more than an ideal; innovation is our way of life. Every day we design new products that are convenient to install and efficient to operate, providing our customers with the highest level of reliability. In other words, we make it our business to develop advanced ideas that deliver advanced solutions. This product guide is divided into four areas: Conventional Detection a complete line of smoke detectors led by the innovative i 3 Series. Audible/Visible Notification the SpectrAlert line, featuring the Selectable Output Series of multiple-candela units. HVAC Systems Monitoring the Innovair line and other specialty detectors designed to detect smoke in the air duct network. Sprinkler Systems Monitoring products designed to sense the flow of water through pipes, switches and valves. C o n v e n t i o n a l D e t e c t i o n i 3 Series Photoelectric Smoke Detectors Installation ease, intelligence and instant inspection are the guiding principles of System Sensor s i 3 Series photoelectric smoke detectors. The i 3 Series is a complete line Standard, Sounder, Auxiliary Form C Relay and Isolated Thermal models featuring plug-in bases, removable covers, remote maintenance signaling, drift compensation and smoothing algorithms, green and red LEDs, and simplified sensitivity measurement. Loop Type Thermal Sounder Form C Relay Avg. Standby Current Max. Alarm Current 2W-B 2-wire No No No VDC 50 µa 130 ma limited by control panel 2WT-B 2-wire Yes No No VDC 50 µa 130 ma limited by control panel 4W-B 4-wire No No No VDC 50 µa 23 ma 4WT-B 4-wire Yes No No VDC 50 µa 23 ma 2WTA-B 2-wire Yes Yes No VDC 50 µa 130 ma* 2WTR-B 2-wire Yes No Yes VDC 50 µa 130 ma limited by control panel 4WTA-B 4-wire Yes Yes No VDC 50 µa 35 ma 4WTR-B 4-wire Yes No Yes VDC 50 µa 35 ma 4WTAR-B 4-wire Yes Yes Yes VDC 50 µa 50 ma 4WITAR-B 4-wire Isolated Yes Yes VDC 50 µa 50 ma * In direct power (non-reverse polarity), the maximum alarm current is 130 ma limited by the panel. In reverse polarity power, the maximum current is 30 ma for the 2WTA-B in alarm; 12 ma for all other 2WTA-B units on the loop. Add 25 ma for the RRS-MOD reversing relay alarm current. 100 Series Plug-in Smoke Detectors The 100 Series low profile plug-in smoke detectors are ideal for light commercial applications. Offered with a photoelectric sensor, the 100 Series may be installed with a range of plug-in bases to accommodate a variety of wiring configurations and voltages. Detection Type Wiring Thermal Avg. Standby Current Max. Alarm Current 2151 Photoelectric Mounting base dependent No See bases 85 µa Mounting base dependent 1

3 400 Series Direct-Wire and Plug-in Smoke Detectors The 400 Series represents a family of conventional smoke and electronic heat detectors in a variety of configurations. Direct-wire models, used with two- or four-wire loops, are available with an ionization sensor. A plug-in ionization model is also available. Detection Type Wiring Thermal Max. Standby Current Max. Alarm Current 1400 Ionization 2-wire No 12/24 VDC 120 µa Limited by the control panel 1412B Ionization 4-wire No 12 VDC 120 µa 77 ma 1424 Ionization 4-wire No 24 VDC 120 µa 41 ma 1451 Ionization Mounting base dependent No See bases 120 µa Mounting base dependent 400 Series Plug-in Electronic Heat Detectors The 400 Series plug-in electronic heat detectors offer thermal detection in both 190 F fixed temperature and 135 F combination fixed/rate-of-rise configurations. Both models may be installed with a range of 400 Series plug-in bases. Temperature Rating Activation Method Max. Standby Current Fixed/Rate-of-rise 100 µa 4451HT 190 Fixed temperature 100 µa 100 Series Plug-in Smoke Detector Bases Designed for use with System Sensor s 100 Series plug-in smoke detectors, the 100 Series bases accommodate 2- or 4-wire loops and 12, 24 or 120 operating voltages to address a broad range of applications. Loop Type Alarm Current B110LP 2-wire 12/24 VDC ma limited by the control panel B110RLP 2-wire 24 VDC ma B112LP 4-wire 24 VDC ma B114LP 4-wire 120 VAC 75 ma (AC) maximum B116LP 2-wire 24 VDC ma limited by the control panel 400 Series Plug-in Smoke Detector Bases Designed for use with System Sensor s 400 Series plug-in smoke detectors, the 400 Series bases are offered in a variety of models for 2- or 4-wire loops and 12, 24 or 120 operating voltages. Loop Type Alarm Contact Type Max. Alarm Current B401 2-wire 12/24 VDC ma limited by the control panel B401B 2-wire 12/24 VDC ma limited by the control panel B401BR 2-wire 24 VDC ma B402B 4-wire Form A & C 24 VDC ma B404B 4-wire Form A & C + A supervisory 120 VAC 75 ma (AC) maximum B406B 2-wire Form C 24 VDC ma limited by the control panel 2

4 5600 Series Mechanical Heat Detectors The 5600 Series mechanical heat detectors offer a low cost means for property protection against fire and for non life-safety installations where smoke detectors are inappropriate. To accommodate a broad range of applications, the 5600 Series is available in a full line of configurations. Single- and dual-circuit models are available with low or high temperature ratings and with fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. Circuit Identification Method on Exterior Temperature Rating Activation Method Protected Spacing** 5601P Single Non-lettered 135 Fixed/Rate-of-rise 50 feet by 50 feet 5602 Single Lettering 194 Fixed/Rate-of-rise 50 feet by 50 feet 5603 Single Lettering 135 Fixed temperature 25 feet by 25 feet 5604 Single Lettering 194 Fixed temperature 25 feet by 25 feet 5621 Dual Lettering 135 Fixed/Rate-of-rise 50 feet by 50 feet 5622 Dual Lettering 194 Fixed/Rate-of-rise 50 feet by 50 feet 5623 Dual Lettering 135 Fixed temperature 25 feet by 25 feet 5624 Dual Lettering 194 Fixed temperature 25 feet by 25 feet **Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. Reflected Beam Smoke Detector The reflected beam smoke detectors incorporate an eight inch reflector for simple installation and alignment. The BEAM 1224S includes an integral sensitivity test feature. Wiring Avg. Standby Current Avg. Alarm Current Range BEAM wire VDC 17 ma 24 VDC 38.5 ma 24 VDC ft. (5m to 100m) BEAM1224S 4-wire VDC 17 ma 24 VDC 38.5 ma 24 VDC ft. (5m to 100m) Conventional Detection Accessories Complementing System Sensor s detection products are a host of accessories sories designed to enhance installation, test, operation, and maintenance. SENS-RDR RRS-MOD 2W-MOD2 RT A77-AB2 XR2B A77-AB RMK400 SMB600 MOD400R A77-716B APA451 BEAMLRK BEAMMMK BEAMSMK BEAMHK BEAMHKR RA400Z RTS451 RTS451KEY Description i 3 series infrared sensitivity reader i 3 series reversing relay / synchronization module i 3 series loop test and maintenance module i 3 series removal/replacement tool i 3 series retrofit adapter bracket 100 series installation/removal tool 100 series retrofit adapter bracket 100/400 series recessed mounting kit 100/400 series surface mount kit 100/400 series field sensitivity test module End of line power supervision relay Remote annunciator with piezo alarm Long-range kit for BEAM1224/BEAM1224S Multi-mount kit for BEAM1224/BEAM1224S Surface-mount kit for BEAM1224/BEAM1224S Heater kit for transmitter/receiver unit Heater kit for reflector Remote annunciator for spot and duct smoke detectors Remote test station accessory Remote test station accessory with key 3

5 A u d i b l e / V i s i b l e N o t i f i c a t i o n Selectable Output Horn/Strobes The Selectable Output Horn/Strobes offer a unique combination of unsurpassed performance with low-profile aesthetics, dual voltage in one unit, candela settings of 15, 15/75, 30, 75, and 110cd, and eight separate horn settings. P1224MC P1224MCW Candela FWR DC FWR Current Horn DC Current Horn 12V 24V 12V 24V 12V 24V 12V 24V / N/A 93 N/A N/A 158 N/A N/A 208 N/A Selectable Output Strobes The Selectable Output Strobes operate at 12 and 24 volts and offer a full complement of candela settings. S1224MC Candela FWR S1224MCW DC 12V 24V 12V 24V / N/A 93 N/A N/A 158 N/A N/A 208 N/A 209 Selectable Output Speaker/Strobes The Selectable Output Speaker/Strobes offer the same strobe features as the Strobes and Horn/ Strobes and the same highly intelligible sound quality as the voice evacuation products. The SP2R1224MCK is rated from 40 F to +151 F for outdoor operation. SP2R1224MC, SP2R1224MCK (outdoor) Candela FWR DC SP2W1224MC 12V 24V 12V 24V / N/A 93 N/A N/A 158 N/A N/A 208 N/A 209 Horns The Horns provide eight field-selectable and reversible settings, including high or low volume, temporal or non temporal, and electromechanical or 3000HZ. FWR Current DC Current 12V 24V 12V 24V 4 H12/24 H12/24W

6 Selectable Output Outdoor Horns and Strobes The Selectable Output Outdoor Horns and Strobes contain the same features as the indoor horns and strobes and are UL listed and NEMA 3 approved. Candela FWR DC FWR Current Horn DC Current Horn 12V 24V 12V 24V 12V 24V 12V 24V P1224MCK / N/A 93 N/A N/A 158 N/A N/A 208 N/A S1224MCK / N/A 93 N/A N/A 158 N/A N/A 208 N/A 209 H12/24K N/A N/A N/A N/A N/A * For outdoor applications, mount devices to weatherproof back box, model WBB. Selectable Output Chimes and Chime/Strobes The Selectable Output Chimes and Chime/Strobes (wall-mounted and electronic) have sixteen field-selectable chime tones and three volume settings. Intended for private mode applications, the chime meets UL 464 and the chime/strobe meets UL1971. CH24MC Candela CH24MCW CH1224 CH1224W 12/24 Electronic Chime Current Draw (ma): Tone FWR / DC Current Draw at 8-33 VDC: ma (Average current draw varies with tones selected. See table below.) Current ratings per System Sensor testing at 12VDC and 24VDC. 8 Volts 12 Volts 24 Volts 33 Volts Low Med. High Low Med. High Low Med. High Low Med. High 1.2K Repeating 1-Second Chime K Repeating 1-Second Chime K Repeating 1-Second Chime K Repeating 1 /4-Second Chime K Repeating 1 /4-Second Chime K Repeating 1 /4-Second Chime K Temporal 3 Chime K Temporal 3 Chime K Temporal 3 Chime K Single Stroke Chime K Single Stroke Chime K Single Stroke Chime K Continuous Electromechanical K Temporal Electromechanical K Continuous Electromechanical K Temporal Electromechanical

7 Ceiling Mount Horn/Strobes Since their introduction, the SpectrAlert series of ceiling-mounted notification devices has become widely regarded as the most complete and innovative in the industry. Candela FWR Max. DC Max. FWR Max. Current Horn PC2415 PC2415W PC PC241575W 24 15/ PC2430 PC2430W PC2475 PC2475W PC2495 PC2495W PC24115 PC24115W PC24177 PC24177W DC Max. Current Horn Ceiling Mount Strobes The circular Ceiling Mount Strobes are modeled specifically for ceiling use. The strobes offer a full complement of candela settings. Candela FWR Max. Current SC2415 SC2415W SC SC241575W 24 15/ SC2430 SC2430W SC2475 SC2475W SC2495 SC2495W SC24115 SC24115W SC24177 SC24177W DC Max. Current Ceiling Mount Speaker/Strobes The Ceiling Mount Speaker/Strobes offer the same clarity and intelligibility as the speaker products and the full complement of candela settings available throughout the ceiling product family. Candela FWR Max. Current SP2C SP2C / SP2C SP2C SP2C SP2C SP2C DC Max. Current 6

8 Dual Evacuation Speakers The Dual Evacuation Speakers provide the highly intelligible sound quality essential to voice evacuation. These products are low in harmonic distortion and feature a frequency range that exceeds most codes. The SP201K is rated from 40 F to +151 F for outdoor operation. Description Speaker N/A SP200W Round 7 3 /8 grille, 1 /4-2 watt power tap 25.0/70.7 Vrms SP201R SP201W Square 5 grille, 1 /4-2 watt power tap 25.0/70.7 Vrms SP201K Outdoor listed, square 5 grille, 1 /4-2 watt power tap 25.0/70.7 Vrms Sync Circuit Module The SpectrAlert Sync Circuit Module is designed to simplify installations requiring signal synchronization. Average Current (ma) Peak Current (ma) In-rush Current (ma) DC FWR DC FWR DC FWR MDL MDLW Accessory Mounting Plates The Accessory Mounting Plates can be used with wall- or ceiling-mount horns, strobes and horn/strobes. Description S-MP S-MPW Small footprint mounting plate for single gang only BBS BBSW Surface-mount back box skirt D-MP D-MPW Universal mounting plate (replacement) WBB NA Weatherproof back box BBSC BBSCW Surface-mount back box skirt for ceiling mount products BBS-SP2R BBS-SP2RW Surface-mount back box skirt for wall mount speaker/strobe BBS-CHSR BBS-CHSW Surface-mount back box skirt for wall mount chime/strobe BBS-SP201R BBS-SP201W Surface-mount back box skirt for SP201 speakers 7

9 H V A C S y s t e m s M o n i t o r i n g During a fire, an HVAC system can deliver toxic gasses and smoke throughout a building unless that building is equipped with Innovair duct smoke detectors. The Innovair line features: Connectivity Up to 10 Innovair 4-wire devices can be interconnected so when one alarm is activated, auxiliary relays in others will initiate control over fans, dampers, doors, etc. Easy Installation Innovair duct detectors with duct widths from inches are equipped with built-in sampling tubes. Accessory sampling tubes are also available for duct widths up to 12 feet. Captured cover screws and exterior mounting tabs simplify installation. Easy Maintenance and green LEDs assure quick and convenient status checks; the missing signal assures system integrity; the reset button on the front cover simplifies system covertesting. Model Description Wiring DH100LP DH100ACDCLP DH100ACDCLWP DH100ACDCI DH400ACDCIHT Photoelectronic low-flow duct smoke detector Photoelectronic low-flow duct smoke detector Watertight photoelectronic low-flow duct smoke detector Ionization duct smoke detector High-temperature ionization duct smoke detector 2151 Photoelectric no-flow/ low-fl ow smoke detector Air Velocity Range Temp. Range 2-wire ft/min wire ft/min wire ft/min wire ft/min wire ft/min wire ft/min Rating Alarm Current 12/24 VDC 4.2 VDC min at 10 ma, 6.6 VDC max at 130 ma Auxiliary Contact 24 VAC/DC or 120/240 VAC 70 ma max 2 Form C Auxiliary Relay NEMA 4 24 VAC/DC or 120/240 VAC 70 ma max 2 Form C Auxiliary Relay 24 VAC/DC or 120/240 VAC 70 ma max 2 Form C Auxiliary Relay 24 VAC/VDC or 120/220 VAC 95 ma max 2 Form C Auxiliary Relay 24 VAC/DC w/b114lpbt base; 120 VAC w/b114lp base 75 ma max 1 Form A & 1 Form C Auxiliary Relay Model Description SSK451 Multi-signaling accessory, remote test station with horn, allows local testing of a remote duct detector, for use with System Sensor DH100ACDC and DH400ACDC VDC APA451 Remote annunciator with piezo alert VDC RA400Z Remote annunciator for spot and duct smoke detectors VDC RTS451 Remote test station accessory VDC (Alarm LED) RTS451KEY Remote test station accessory with key reset VDC (Power LED); VDC (Alarm LED) RTC100 Remote test coil kit with low-profile ring (includes RTS451 remote test station) PS24LO(W) Mini-Alert add-on strobe for use with SSK451 or PA400W VDC S p r i n k l e r Sy s t e m s M o n i t o r i n g WFD Series Waterflow Detector The WFD Series waterflow detectors are available in a range of sizes to accommodate fire sprinkler risers from two to eight inches. All units feature vane-type paddles and an adjustable mechanical relay. 8 Model Pipe Size Hole Size Pressure Rating Contact Ratings Triggering Threshold WFD /4 450 PSI 2 Form C: 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC 4-10 GPM WFD /2 1 1 /4 450 PSI 2 Form C: 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC 4-10 GPM WFD PSI 2 Form C: 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC 4-10 GPM WFD /2 1 1 /4 450 PSI 2 Form C: 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC 4-10 GPM WFD PSI 2 Form C: 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC 4-10 GPM WFD PSI 2 Form C: 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC 4-10 GPM WFD PSI 2 Form C: 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC 4-10 GPM WFD PSI 2 Form C: 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC 4-10 GPM

10 T-Tap Series Waterflow Detector The T-Tap waterflow detectors are compatible with one-inch NPT style connections, making them ideal for residential or branch line signaling applications. Model WFDT WFDTH WFDTNR Compatible Tee Fittings 1 to 1 1 /2 NPT threaded ferrous and brass, 1 to 2 sweat brass, 1 1 /2 polybutylene plastic, 1 PVC plastic tees having a 1 threaded NPT branch, and 2 cast and malleable threaded tees. 1 to 1 1 /2 NPT threaded ferrous and brass, 1 to 2 sweat brass, 1 1 /2 polybutylene plastic, 1 PVC plastic tees having a 1 threaded NPT branch, and 2 cast and malleable threaded tees. 1 to 1 1 /2 NPT threaded ferrous and brass, 1 to 2 sweat brass, 1 1 /2 polybutylene plastic, 1 PVC plastic tees having a 1 threaded NPT branch, and 2 cast and malleable threaded tees. Pressure Rating Contact Ratings 250 PSI 2 Form C: 125/250 VAC, 2.5 A 24 VDC 250 PSI 2 Form C: 125/250 VAC, 2.5 A 24 VDC 250 PSI 2 Form C: 125/250 VAC, 2.5 A 24 VDC Triggeringing Threshold 4-10 GPM 4-10 GPM 4-10 GPM Supervisory Switches System Sensor manufactures devices for supervising a variety of control valves, including outside screw and yoke, post indicator, butterfly, and rising and non-rising stem gate. Model Description Valve Size Contact Rating OSY2 PIBV2 PSP1 Used to monitor the open position of an Outside Screw and Yoke type gate valve Used to monitor the open position of post indicator and butterfl y control valves A plug-in special application supervisory switch designed for applications where no other type of listed valve supervisory switch can be used 1 to /250 VAC; 2.5 6/12/24 VDC /250 VAC; 2.5 6/12/24 VDC Plug Contacts: 6/12/24 VAC/DC, normally open Cover Tamper: 125/250 VAC, 6/12/24 VAC Maximum Current 250mA EPS Series Pressure Switches The EPS Series Pressure Switches are offered in three varieties and with one or two SPDT contacts. The EPS10 alarm pressure switches are ideal for dry pipe systems while the EPS40 and EPS120 supervisory pressure switches are intended for supervising air pressure in pipes or pressure tanks. Model EPS10-1 EPS10-2 EPS40-1 EPS40-2 EPS120-1 EPS120-2 Maximum Pressure Maximum Adjustment Range Differential Contact Rating 250 psi 4 to 20 psi 3 psi 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC 250 psi 10 to 100 psi 3 10 psi and 6 psi at 100 psi 250 psi 10 to 200 psi 3 10 psi and 9 psi at 200 psi 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC 10 A, 1 /2 125/250 VAC; 2.5 6/12/24 VDC Threaded Connection 1 /2 NPT male reinforced nylon 1 /2 NPT male reinforced nylon 1 /2 NPT male reinforced nylon Alarm Bells The Alarm Bells offer high output notification in security and fire alarm systems. Six, eight and ten inch models are available for 24 VDC and 120 VAC systems. Model Gong Size Nominal Sound Output Maximum Current SSM VDC VDC 82 db DC ma / FWR ma SSM VDC VDC 80 db DC ma / FWR ma SSM VDC VDC 81 db DC ma / FWR ma SSV VAC VAC 85 db 53 ma SSV VAC VAC 82 db 53 ma SSV VAC VAC 82 db 53 ma 9

11 System Sensor is a global manufacturer of fire detection and notification devices, specializing in smoke detection and notification technology. System Sensor places a premium on research and development, resulting in products that are reliable, sophisticated and designed for real-world applications. With sales, service and manufacturing facilities throughout the Americas, Europe and Asia, System Sensor s high quality, innovative products are the most comprehensive in the industry System Sensor. The company reserves the right to change specifications at any time. A /05 #1445

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize advanced ideas advancedsolutions At System Sensor, Research and Development is more than a department. It s a way of life. Every day we work to design new products that utilize the most innovative technologies

More information

Fire Safety Products. Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring

Fire Safety Products. Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring F U L L - L I N E P R O D U C T G U I D E Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring At System Sensor, innovation is more

More information

Full Line Catalog and Product Brochures

Full Line Catalog and Product Brochures Welcome to E DOCS Electronic Documents on CD-ROM This disc contains Product s Product Installation s Agency Listings Applications Guides Full Line Catalog and Product Brochures click below to search by

More information

Manual Call Point-Installation efficiency, Flexibility and full compliance with latest standards are at the heart of new Indoor Call Point range.

Manual Call Point-Installation efficiency, Flexibility and full compliance with latest standards are at the heart of new Indoor Call Point range. At System Sensor, innovation is more than an ideal; innovation is our way of life. Every day we design new products that are convenient to install and efficient to operate, providing our customers with

More information

Fire Safety Product Catalog

Fire Safety Product Catalog Fire Safety Product Catalog Innovation is our way of life. At System Sensor, innovation is our way of life. Every day we design new products that are convenient to install and efficient to operate, providing

More information

Fire & Life Safety Products CATALOG

Fire & Life Safety Products CATALOG Fire & Life Safety Products CATALOG Audible/Visible Notification Beam Smoke Detection Carbon Monoxide Detection HVAC Duct Smoke Detection and Monitoring Smoke Detection Fire Sprinkler Systems Monitoring

More information

Bid Specifications. Fire Alarm Equipment and Parts. USA Bid No

Bid Specifications. Fire Alarm Equipment and Parts. USA Bid No Bid Specifications Fire Alarm Equipment and Parts USA Bid No. 4120302 Equivalent Mfr. Part No. Manufacturer Equivalent Item Description 21006374 Kidde Kidde Smoke Detector 50 21006371 Kidde Kidde Smoke

More information

Reshaping Duct Smoke Detection

Reshaping Duct Smoke Detection Reshaping Duct Smoke Detection When System Sensor introduced the Innovair line of duct smoke detectors and accessories, it was revolutionary. Mechanical contractors and fire systems installers like you

More information

Fire Sprinkler Monitoring Products. Solutions and Service for Sprinkler System Integrity

Fire Sprinkler Monitoring Products. Solutions and Service for Sprinkler System Integrity Fire Sprinkler Monitoring Products Solutions and Service for Sprinkler System Integrity waterflow monitoring Monitoring Fire Sprinkler System Flow During a fire condition, sprinkler system reliability

More information

Reshaping Duct Smoke Detection

Reshaping Duct Smoke Detection Reshaping Duct Smoke Detection Y TE + TEST COIL TEST COIL + IN + OUT RA + RA + RTS (+) 24 VDC AUX POWER SUPPLIED BY USER (100mA SUPPLY) 24 VAC (+10%, 15%) FULL WAVE RECTIFIED, UNFILTERED POWER MAY BE USED

More information

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL March 30, 2000 Section: Audio/Visual Devices G-250 SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL System Sensor SpectrAlert Series strobes, horns, and combination horn/strobes are UL listed

More information

The Advance You ve Been Looking For

The Advance You ve Been Looking For The Advance You ve Been Looking For The Power Behind The Products System Sensor was founded in 1984 and today is the largest manufacturer of fire detection and notification appliances in the world. More

More information

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E SpectrAlert Advance Description System Sensor SpectrAlert Advance offers a variety of devices designed for mass notification, including plain devices for non-fire applications, amber lens strobes and speaker

More information

Agent Release Control Panel

Agent Release Control Panel Agent Release Control Panel System Capacity Annunciators: 8 Electrical Specifications RP-2002 (FLPS-7 Power Supply): 120 VAC, 60 Hz, 3.66 amps RP-2002E (FLPS-7 Power Supply): 240 VAC, 50 Hz, 2.085 amps

More information

Selectable Output Chimes and Chime/Strobes

Selectable Output Chimes and Chime/Strobes Selectable Output Chimes and Chime/Strobes PRELIMINARY DN-60940:A Audio/Visual Devices General System Sensor L-Series selectable-output chimes and chime/ strobes are rich with features guaranteed to cut

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 042010 Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).

More information

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ELECTRONIC SOUNDER STROBE Model : AVD-C407 ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an

More information

SECTION FIRE ALARM SYSTEMS

SECTION FIRE ALARM SYSTEMS SECTION 16721 FIRE ALARM SYSTEMS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work

More information

Vista-20SEUL System Design Sheet

Vista-20SEUL System Design Sheet System Design Sheet INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO SECTION 1: Basic -Features QED programming for quick enrollment of devices (Eight Hardwired Zones, Wireless) Part

More information

L-Series, Emergency Communication Devices

L-Series, Emergency Communication Devices Notification Appliances L-Series, Emergency Communication Devices Description The L-Series Emergency Communications devices and accessories combine application versatility with all of the same time-saving

More information

good things in small packages

good things in small packages FireShield Control Panels good things in small packages life safety for small buildings and shops A perfect arrangement FireShield offers the very best conventional fire alarm technology available, with

More information

Vista-50P/-50PUL System Design Sheet

Vista-50P/-50PUL System Design Sheet Vista-50P/-50PUL System Design Sheet INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO ACCESS CONTROL SECTION 1: Basic Vista-50P (Nine Hardwired Zones, One Addressable Loop, Wireless)

More information

Addressable Detectors & Bases

Addressable Detectors & Bases Edwards Signaling Catalog u Intelligent Initiating Addressable Detectors & Bases Detectors: E-PD, E-PHD, E-HD Bases: B4U, RB4U, IB4U, SB4U Overview Edwards intelligent addressable detectors are meticulously

More information

Vista-128FB System Design Sheet

Vista-128FB System Design Sheet Vista-128FB System Design Sheet FIRE DETECTION SPRINKLER SUPERVISION INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO ACCESS CONTROL SECTION 1: Basic Vista-128FB (Eight Hardwired Zones,

More information

AL600ULX Series. Power Supply/Charger. Installation Guide

AL600ULX Series. Power Supply/Charger. Installation Guide AL600ULX Series Power Supply/Charger Installation Guide Models Include: AL600ULX - Single Output AL600ULPD4 AL600ULPD4CB - Four (4) Fused Outputs - Four (4) PTC Outputs AL600ULPD8 AL600ULPD8CB - Eight

More information

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors Carbon Monoxide (CO) Detection PRODUCTS Accessories Conventional Detectors 2 Complete CO Detection The system-connected CO1224T and CO1224TR CO detectors with RealTest provide early warning by using reliable

More information

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X AL1002ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 071508X Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).

More information

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs AL400ULX Series Power Supply/Charger Installation Guide Models Include: AL400ULX - Single Output AL400ULPD4 AL400ULPD4CB - Four (4) Fused Outputs - Four (4) PTC Outputs AL400ULPD8 AL400ULPD8CB - Eight

More information

L-Series, Indoor Strobes and Horn Strobes

L-Series, Indoor Strobes and Horn Strobes Notification Appliances L-Series, Indoor Strobes and Horn Strobes Indoor Selectable-Output Strobes/Horn Strobes for Ceiling Applications General The L-Series audible visible notification products offer

More information

DH100ACDCI Ionization Air Duct Smoke Detector

DH100ACDCI Ionization Air Duct Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS Ionization Air Duct Smoke Detector Before Installing Please thoroughly read the System Sensor Guide for Proper Use of Smoke Detectors in Duct Applications (A05-1004),

More information

L-Series, Indoor Strobes and Horn Strobes

L-Series, Indoor Strobes and Horn Strobes Notification Appliances L-Series, Indoor Strobes and Horn Strobes Indoor Selectable-Output Horns, Strobes and Horn Strobes for Wall Applications General The L-Series audible visible notification products

More information

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X AL1042ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 071508X Agency Listings: UL Listed for Control Units for Fire Protective Signaling Systems (UL

More information

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs AL300ULX Series Power Supply/Charger Installation Guide Models Include: AL300ULX - Single Output AL300ULPD4 AL300ULPD4CB - Four (4) Fused Outputs - Four (4) PTC Outputs AL300ULPD8 AL300ULPD8CB - Eight

More information

WFDE Series Waterflow Detector

WFDE Series Waterflow Detector WFDE Series Waterflow Detector The System Sensor WFDE series is compatible with pipe diameters ranging from 50mm through 200mm and can be mounted in a vertical or horizontal position. Features Compliant

More information

Analog fire panels FPA-1000 Family

Analog fire panels FPA-1000 Family Analog fire panels FPA-1000 Family en NAC Compatibility List Analog fire panels NAC compatibility en 3 1 NAC compatibility 1.1 General notes Bosch Security Systems found the following notification appliance

More information

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev Altronix Corp. 140 58th St. Brooklyn, NY AL1042ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 052313 Agency Listings: UL Listed for Control Units for

More information

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.

More information

TrueAlert Notification Appliances

TrueAlert Notification Appliances TrueAlert Notification Appliances UL Listed; FM, CSFM and MEA (NYC) Approved* Non-Addressable Audible/Visible Notification Appliances with SmartSync Operation of Strobes and Horns Features Wall mount audible/visible

More information

TRN100BPT, TRN100BP, and TRN100BPC Air Duct Smoke Detector with Extended Air Speed Range

TRN100BPT, TRN100BP, and TRN100BPC Air Duct Smoke Detector with Extended Air Speed Range INSTALLATION AND MAINTENANCE INSTRUCTIONS TRN100BPT, TRN100BP, and TRN100BPC Air Duct Smoke Detector with Extended Air Speed Range 825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 60-77-6495

More information

TrueAlarm Analog Sensing

TrueAlarm Analog Sensing UL, ULC Approved* TrueAlarm Analog Sensing TrueAlarm Analog Sensors Photoelectric and Heat; Standard Bases and Accessories Features TrueAlarm analog sensing provides: Digital transmission of analog sensor

More information

DH100ACDCI Ionization Air Duct Smoke Detector

DH100ACDCI Ionization Air Duct Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS Ionization Air Duct Smoke Detector Before Installing Please thoroughly read the System Sensor Guide for Proper Use of Smoke Detectors in Duct Applications (A05-1004),

More information

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS SXL Conventional Zone Fire Alarm Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS 4 Zones Expandable to 8 Zones Microprocessor Based Control Factory Programmed Field Configurable 2 Style Y Notification

More information

TrueAlarm ES Analog Sensing

TrueAlarm ES Analog Sensing TrueAlarm ES Analog Sensing UL, ULC, CSFM Listed; FM Approved* Features TrueAlarm addressable sensor base with 520 Hz sounder TrueAlarm sensor bases with 520 Hz tone require a TrueAlarm photoelectric,

More information

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi 50 (P/N 10-071) is a state-of-the-art true intelligent digital peer-to-peer modular suppression control system.

More information

Addressable Fire Alarm Control Panel

Addressable Fire Alarm Control Panel PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT

More information

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics by Tomar Electronics SIRENS POWER ALARM PROGRAMMABLE MULTI-SOUND INDUSTRIAL SIGNALS The POWER ALARM siren is a heavy duty industrial audible alarm designed to operate under adverse industrial conditions

More information

DH100ACDCLP Air Duct Smoke Detector with Extended Air Speed Range

DH100ACDCLP Air Duct Smoke Detector with Extended Air Speed Range INSTALLATION AND MAINTENANCE INSTRUCTIONS Air Duct Smoke Detector with Extended Air Speed Range A Division of Pittway 825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 60-77-6495 The Innovair

More information

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi (P/N 10-068) is a state-of-the-art true intelligent digital peer-topeer modular suppression control system. It is ideal for

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

Control / Communicator

Control / Communicator ARMED READY A D S SPACE B E T R C F X ENTER MAX INSTANT READY R BYPASS FA2000C Control / Communicator BS/ESC N/Y SHIFT 1 4 5 6 7 8 9 0 2 # 3 ARMED READY FA560 A 1 OFF 2 AWAY 3 STAY B 4 5 TEST 6 C 7 8 CODE

More information

LifeAlarm Fire Alarm Controls

LifeAlarm Fire Alarm Controls UL, ULC Approved* LifeAlarm Fire Alarm Controls 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs Features Provides additional notification appliance circuit (NAC) capacity

More information

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep. 140 58th St. Brooklyn, NY Power Supply/Chargers Installation Guide Models Include: eflow4n/eflow4nx - 4 amp @ 12VDC or 24VDC eflow4n8/eflow4nx8 eflow4n8d/eflow4nx8d - 4 amp @ 12VDC or 24VDC - 4 amp @ 12VDC

More information

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet Table 1: Models Description Low frequency (520 Hz) horn, white housing, no FIRE marking, standard output clear strobe light Low frequency (520

More information

Signature Series Auto-Sync Output Module (CC1S)

Signature Series Auto-Sync Output Module (CC1S) Signature Series Auto-Sync Output Module (CC1S) Product description Mounting The Signature Series can be mounted in a North American 2-1/2 in (64 mm) deep 2-gang box or a standard 4 in square box 1-1/2

More information

Vista-10SE System Design Sheet

Vista-10SE System Design Sheet Vista-10SE System Design Sheet INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO SECTION 1: Basic Vista-10SE -Features QED programming for quick enrollment of devices Part No. Qty. Each

More information

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING GENERAL The VEC 25/50 is a state-of-the-art, compact, stand-alone or slave Emergency Voice Evacuation Control. The VEC 25/50 is offered in a self-contained, cost-effective design and includes a 25 Watt,

More information

SELECT-A-HORN/STROBE SERIES

SELECT-A-HORN/STROBE SERIES SELECT-A-HORN/STROBE SERIES Features Description Mircom s Select-A-Strobe/Horn Series is designed to comply with the Americans with Disability Act (ADA) and meet UL standard 1971 requirements for emergency

More information

LifeAlarm Fire Alarm Control Panels

LifeAlarm Fire Alarm Control Panels LifeAlarm Fire Alarm Control Panels UL, ULC Approved* Features Control panel operator convenience features: Wide viewing angle 2 x 20 (40 character) alphanumeric LCD and dedicated LEDs provide convenient

More information

Multi-Point Peripherals

Multi-Point Peripherals UL, ULC Approved* Multi-Point Peripherals TrueAlarm CO Sensor Bases for Smoke, Heat, and Photo/Heat Sensors using IDNet Communications Features Fig 1: TrueAlarm CO Sensor Base with Sounder (shown with

More information

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel ACC-25/50ZST Zoned System Voice with Telephone Evacuation Control Panel General The AUDIO COMMAND CENTER 25/50 Zone System with FireFighters Telephone (ACC-25/50ZST) is a state-of-the-art Emergency Voice

More information

INSTALLATION AND MAINTENANCE

INSTALLATION AND MAINTENANCE INSTALLATION AND MAINTENANCE DH100ACDCIA & DH100ACDCPA Air Duct Smoke Detector Before Installing ULC standard CAN/ULC-S524-M91 Standard For The Installation Of Fire Alarm Systems should be referenced for

More information

July 14, 1999 DF C-100.

July 14, 1999 DF C-100. www.firelite.com GENERAL The Fire Lite FIRE COMMAND 25/50 is a state-of-theart, compact, stand-alone or slave Emergency Voice Evacuation Control Panel (VECP). The FIRE COMMAND 25/50 is offered in a self-contained,

More information

Potter Wall Mount Select-A-Strobe

Potter Wall Mount Select-A-Strobe 104 Kenran Industrial Dr. Potter Wall Mount Select-A-Strobe SL-1224 SERIES SELECT-A-STROBE Call for additional listings 12 VDC with 15, 35 or 60 cd setting 24 VDC with 15, 35, 60, 5, 95 or 110 6 distinct

More information

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card XP6-C Six Circuit Supervised Control Module and SYNC-1 Accessory Card General NOTIFIER s XP6-C six-circuit supervised control module provides intelligent alarm systems with supervised monitoring of wiring

More information

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances UL, ULC Listed* TrueAlert Addressable Notification Appliances Audible/Visible Notification Appliances; Multi-Tone Horn/Strobe with 520 Hz Output Features Individually addressed and controlled multi-tone

More information

TrueAlarm Analog Sensing

TrueAlarm Analog Sensing TrueAlarm Analog Sensing UL, ULC Listed* Addressable Duct Sensor Housings with TrueAlarm Photoelectric Sensor; Available with Multiple Relay Features Compact air duct sensor housing with clear cover to

More information

D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installing detectors, please thoroughly read the NEMA Guide for Proper Use

More information

Multi-Point Peripherals

Multi-Point Peripherals Multi-Point Peripherals UL, ULC, CSFM Listed; FM Approved* TrueAlarm CO Sensor Bases for Smoke, Heat, and Photo/Heat Sensors using IDNet Communications Features TrueAlarm addressable CO sensor bases contain

More information

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions TrueAlert NonAddressable, MultiCandela Notification Appliances Installation Instructions PRODUCT IDENTIFICATION REFERENCE (See Page 4 for Detailed Product Specifications) Type Mount Model Color Operation

More information

CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information

CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information OF FIRE CS24C Colored Light Strobe/orn Series igh Candela Ceiling/Wall Mount Patent Pending Description AMSECO's UL listed Colored Light Strobe CS24C series is designed to provide audible and visual signals

More information

Xenex Conventional Fire Detection & Alarm System

Xenex Conventional Fire Detection & Alarm System SECTI 4: page 1 Section 4: Xenex Conventional Fire Detection & Alarm System SECTI 4: page 3 Xenex system architecture Beam Transmitter Beam Receiver End of Line Call Point Smoke Detector Smoke Detector

More information

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE Cookson 100 Elmwood Avenue Crestwood Industrial Park Mountaintop, PA 18707 Phone: 800-233-8366 Fax: 800-526-0841 CornellCookson.com O W N E R S M A N U A L M O D E L S F I R E G A R D M C F I R E G A R

More information

CO/Smoke Detection PRODUCTS. Accessories Conventional Detectors and Modules

CO/Smoke Detection PRODUCTS. Accessories Conventional Detectors and Modules CO/Smoke Detection PRODUCTS Accessories Conventional Detectors and Modules 2 4 Increase your sales, RMR and customer retention......by protecting your customers from fire and deadly CO gas. Did you know

More information

Multiple Input and Output Modules

Multiple Input and Output Modules Kingfisher Company, inc. Multiple Input and Output Modules Features: Removable 12 to 18 AWG plug-in terminal blocks Individual LED indicators Unused addresses may be disabled Rotary address switches Class

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

Firelite CONVENTIONAL FIRE ALARM CONTROL PANELS CONVENTIONAL PANEL W/ BUILT-IN DIGITAL ALARM COMMUNICATOR

Firelite CONVENTIONAL FIRE ALARM CONTROL PANELS CONVENTIONAL PANEL W/ BUILT-IN DIGITAL ALARM COMMUNICATOR Firelite CONVENTIONAL FIRE ALARM CONTROL PANELS 2-ZONE FIRE ALARM CONTROLS MS-2 Fire Alarm Control Panel, 2-Zone, Class B, 24VDC, One Class B $455.00 NAC MS-2E Export version of MS-2; 220 Volts $455.00

More information

Life safety notification

Life safety notification LED Wheelock Exceder LED3 Life safety notification Meeting the latest codes with increased energy-efficiency in a compact design Wheelock Exceder LED3 Compliant, compatible, compact, and energy efficient

More information

Conventional Fire Detection

Conventional Fire Detection SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct

More information

SAFEPATH Mass Notification System (SPMNS)

SAFEPATH Mass Notification System (SPMNS) Supersedes February 2016 SAFEPATH Mass Notification System (SPMNS) SP40S SPB-320 SPB-80/4 SPB-160 PS-8-LP SPMNS-MIC SP4Z-A/B Contents Page SPMNS.... 2-4 SPMNS-MIC...3 Expansion Options SAFEPATH 2-zone

More information

The complete conventional fire warning system

The complete conventional fire warning system The complete conventional fire warning system www.espuk.com MAG2P 2 Zone Fire Panel 2 programmable zones Active end of line monitoring and head removal 30 fire detectors per zone Unlimited number of call

More information

Addressable and Conventional Fire Protection

Addressable and Conventional Fire Protection Addressable and Conventional Fire Protection Simply reliable F I R E P R O T E C T I O N The MAGPro and Fireline systems has been created to balance performance, reliability and aesthetics whilst being

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5 Construction Standards Page 1 of 5.1 General Description.1 The University requires that all new fire alarm system control panel, components, and devices, as required for the project, be Secutron 2900 Series

More information

DH500ACDC Intelligent Air Duct Smoke Detector Housing

DH500ACDC Intelligent Air Duct Smoke Detector Housing INSTALLATION AND MAINTENANCE INSTRUCTIONS DH500ACDC Intelligent Air Duct Smoke Detector Housing 3825 Ohio Avenue St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 Specifications Length: 14.5

More information

SP40S-D. Kingfisher Company, inc. Features: Description:

SP40S-D. Kingfisher Company, inc. Features: Description: Kingfisher Company, inc. SP40S-D Features: Multi-use applications The system can function as an evacuation system, an emergency messaging system, and an employee notification system Fire code applications

More information

WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE EST LIFE SAFETY PRODUCTS DETECTORS AND MODULES ... EDWARDS SYSTEMS TECHNOLOGY

WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE EST LIFE SAFETY PRODUCTS DETECTORS AND MODULES ... EDWARDS SYSTEMS TECHNOLOGY S I G N A T U R E S E R I E S WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE.... EST LIFE SAFETY PRODUCTS...... DETECTORS AND MODULES... EDWARDS SYSTEMS TECHNOLOGY TM SIGNATURE SERIES LIFE SAFETY DEVICES.

More information

16721 FIRE ALARM AND DETECTION SYSTEMS

16721 FIRE ALARM AND DETECTION SYSTEMS 16721 FIRE ALARM AND DETECTION SYSTEMS PART 1: GENERAL 1.01 QUALITY ASSURANCE A. The integrated fire alarm system including all equipment, components, and accessories shall be UL listed for the purpose

More information

DH100ACDCLPX Air Duct Smoke Detector with Extended Air Speed Range

DH100ACDCLPX Air Duct Smoke Detector with Extended Air Speed Range INSTALLATION AND MAINTENANCE INSTRUCTIONS DH100ACDCLPX Air Duct Smoke Detector with Extended Air Speed Range 3825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 The Innovair

More information

!+ NCA-2-TC Network Control Annunciator-2, 640-characters-Traditional Chinese Network Control Annunciator-2, Traditional Chinese $1,587.

!+ NCA-2-TC Network Control Annunciator-2, 640-characters-Traditional Chinese Network Control Annunciator-2, Traditional Chinese $1,587. Notifier-Honeywell Description Short Description List Intelligent Control Panels & Addressable Initiating Devices ONYX NFS2-3030 Fire Alarm Control Panel CPU2-3030D NFS2-3030 CPU with 640-character Display;

More information

16721 FIRE ALARM AND DETECTION SYSTEMS

16721 FIRE ALARM AND DETECTION SYSTEMS 16721 FIRE ALARM AND DETECTION SYSTEMS PART 1: GENERAL 1.01 QUALITY ASSURANCE A. The integrated fire alarm system including all equipment, components, and accessories shall be UL listed for the purpose

More information

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS PXL Conventional Zone Fire Alarm Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS 12 Zone System Expandable to 32 10 Amp Base Power Supply Multiple Power Supplies Available - Local or Remote 4 Notification

More information

WINDOW & HVAC REPLACEMENT PEMBERTON TOWNSHIP BOE REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5450E

WINDOW & HVAC REPLACEMENT PEMBERTON TOWNSHIP BOE REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5450E SECTION 283111 DIGITAL ADDRESSABLE FIRE ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary General Conditions of the

More information

SAFEPATH SAFEPATH. Emergency communications system

SAFEPATH SAFEPATH. Emergency communications system SAFEPATH SAFEPATH Emergency communications system ALERiTY Integrated mass notification solutions by Eaton; designed to protect, alert and inform your most critical resources your people ALERiTY /a ler

More information

SECTION FIRE ALARM, DETECTION AND NOTIFICATION SYSTEM

SECTION FIRE ALARM, DETECTION AND NOTIFICATION SYSTEM SECTION 16732 FIRE ALARM, DETECTION AND NOTIFICATION SYSTEM PART 1 GENERAL 1.01 SUMMARY A. The work covered by this Section of the Specification shall include all labor, equipment, materials and services

More information

Unified Fire Authority - Fire Prevention Bureau

Unified Fire Authority - Fire Prevention Bureau Unified Fire Authority - Fire Prevention Bureau FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance

More information

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906 s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones

More information

DETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS

DETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS TEST LOG Detector Identification Information Manufacturer and Serial Date Detector Model: Number: Installed: Description of Detector Location: Test Results and Maintenance Data Date Test Test Maintenance

More information

Inspector: PROPERTY INFORMATION Photo Smoke Detector Notification Control Panel Stand Alone Smoke Detector Dialer SUMMARY ONLY

Inspector: PROPERTY INFORMATION Photo Smoke Detector Notification Control Panel Stand Alone Smoke Detector Dialer SUMMARY ONLY FIRE ALARM INSPECTION AND TESTING SUMMARY PAGE PER 2013 NFPA 72 Inspector: Jim Smith Test Date: 5/22/2014 PROPERTY INFORMATION Name of Property: Windsor Tower Owner of Property: Jim Gibbs Properties Address:

More information

USAutomatic Sprinkler Corporation

USAutomatic Sprinkler Corporation Inspection Report Information For CITY OF WESTFIELD - PUBLIC SAFETY Prepared by: T.Hughes, C.Gibbs a fire protection company Sheet 1 of 2 Phone: (317) 573-8160 Fax: (317) 573-8161 110370 REPORT OF INSPECTION

More information