1 (Loss Control through Engineering) Company Profile & Capability Document
2 INTRODUCTION ELC International Inc., an independent consultancy firm established in 2006, specializes in providing engineering solutions in the field of Process and Industrial Safety, Hazard Identification, Risk Assessment and Loss Control to Oil Refineries, Petrochemical, Gas Processing Plants, and Oil Sands production. ELC International Inc. has the expertise necessary to identify the hazards, assess risks and provide practical, pragmatic, site specific and cost effective solution to all problems related to Safety & Loss Control for the protection of life, assets and the environment. ELC International Inc. is committed to provide professional, timely, and tailored engineering solution to our clients that will meet their requirements and exceed their expectations. This document provides an overview of the wide range of services offered by ELC International Inc.
3 MISSION STATEMENT ELC International Inc. is committed to provide quality engineering services to assist our clients in controlling and mitigating harm to people and financial losses from preventable causes and improve their profitability.
4 SERVICES OFFERED DESIGN SAFETY Design Safety support for projects, large or small, from conceptual stage to construction, is available covering the following areas: Safety Philosophy Safety Concept Fire Prevention and Flammable/Toxic Gas detection Philosophy Emergency Response Plan: Identify credible emergency scenarios and determine mitigation measures. Produce a plan identifying responsible personnel, line of command, procedure(s) to be followed, means of communication, resources to be deployed and post-incident recovery. Active Fire Suppression Systems (deluge, water mist, clean agent, foam) Fire water (FW) system design: FW demand, FW storage, FW main and jockey pump capacity and sparing philosophy, FW ring main routing and sizing, and location of isolation valves, hydrants, and monitors. Passive Fire Protection: Assess pool and jet fire hazard, recommend where passive fire protection is needed (pipe rack support, vessel skirt, cable tray etc), what type (SS jacketing on process insulation, cement-based, epoxy), and to what extent. Consequence Analysis: Model potential loss of containment using Phast (or equivalent) software to determine the extent of thermal radiation (jet, pool or flash fire), blast overpressure, threshold limit value (TLV) boundaries for toxic components and probable loss of life/ maximum foreseeable loss. Fire and Gas Detection Systems: Assess probable sources of loss of containment, determine location of the detectors, type of detectors (3IR, infrared, catalytic bead, point vs. open path), voting logic and action upon activation. Plant Layout Review: Ensure compliance with customer s, national and international codes and standards, recommend inter-unit and interequipment spacing and arrangement, mitigate identified hazards, recommend location of permanent and portable occupied buildings.
5 Code analysis: Compliance with Alberta/National Building and Fire Codes Escape, Evacuation and Rescue Analysis (EERA): Analyze the requirements for escape, evacuation and rescue for major accident hazards (MAH) scenarios and recommend measures to reduce risk of harm to people to as low as reasonably practicable (ALARP). Provide EERA plan/drawings showing escape/ evacuation routes, and muster and embarkation points. Safety Equipment Analysis (type, quantity, and location) Third party review of Consultant s reports and studies TRAINING The following training courses tailored to meet your organization s specific needs are offered on an in-house basis at your premises providing the most cost effective means of meeting the training needs of your personnel: Safety and Loss Control Management Hazard and Operability Study (HAZOP) Accident/Incident Investigation Permit to Work System Confined Space Entry Occupational Health H2S Hazards Other courses can be arranged to meet the specific needs of your organization. PROCEDURES & MANUALS Loss Control Standard Manual Safety Procedure & Regulation Manual Emergency Plan & Procedure Manual Hazardous Substance Manual Safety Equipment Specification Manual Engineering Standards
6 OUR TEAM Highly qualified professionals with unique international experience and expertise in the field of Design Safety, Occupational Health, Hazard Analysis and Loss Control are available to provide necessary services to our clients. This expertise can be supplemented by use of associated consultants if needed. PROFILE OF THE PRESIDENT Muhammad Tariq, CEO and President of ELC International Inc., is a Chemical Engineer with a Post Graduate Diploma in Business Administration. He is a Certified Fire Protection Specialist (an ANSI accredited certification program from NFPA).He has 43 years of professional experience working with Refineries, Petrochemical, Gas Liquefaction plants, EPC companies and Regulatory industry. Muhammad is a Professional Engineer licensed in the provinces of Ontario and Alberta in Canada and is a voting member of National Fire Protection Association (NFPA). Muhammad had been an Associate Accredited Safety Auditor from Det Nortske Veritas (DNV), USA, Professional Member of American Society of Safety Engineers and International Society of Risk & Safety Management, UK. Muhammad has extensive experience in the field of Design and Industrial Safety, Health and Environment including the development of HSE management systems, conducting training courses, and writing standards and specifications.
Explosion Protection Engineering Principles
Handbook of Fire and Explosion Protection Engineering Principles for Oil, Gas, Chemical and Related Facilities Second edition Dennis P. Nolan ELSEVIER AMSTERDAM BOSTON HEIDELBERG LONDON NEW YORK OXFORD
More informationAVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY
AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY World-class services help reduce incidents, protect the environment, and keep people and plants safe White Paper PAGE 1 Introduction
More informationAVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY
AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY World-class services help reduce incidents, protect the environment, and keep people and plants safe White Paper PAGE 1 Introduction
More informationSmoke detection in hazardous areas:
WHITE PAPER Smoke detection in hazardous areas: What you need to know Smoke detection in hazardous areas requires detectors that operate effectively and safely in explosive environments. Having the correct
More informationUsing CFD to Analyze Gas Detector Placement in Process Facilities
Using CFD to Analyze Gas Detector Placement in Process Facilities Presented by: Scott G. Davis, Olav R. Hansen, Filippo Gavelli and Are Bratteteig GexCon Outline Background CFD based dispersion study Gas
More informationNEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION EMPLOYER S REQUIREMENTS
Mandatory Fire Safety Instruction NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION EMPLOYER S REQUIREMENTS Reference A: Reference B: Approved Document B
More informationFUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK
FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK USEFUL TERMINOLOGY BASIC PROCESS CONTROL SYSTEM (BPCS) System which responds to input signals from the process, its associated equipment, other programmable
More informationStena Clyde. Engine Room Fire 20 th October 2007
Engine Room Fire 20 th October 2007 Sequence of Events: Refer to previous presentations to HSE Managers 19:56 Alarm raised 19:58 Muster & enter area 20:37 Identify fire call Ariki for assistance 20:13
More informationBALANCING FIRE SAFETY AND ENVIRONMENTAL LIABILITIES: TRANSITIONING FIREFIGHTING FOAMS
BALANCING FIRE SAFETY AND ENVIRONMENTAL LIABILITIES: TRANSITIONING FIREFIGHTING FOAMS A CALL TO ACTION TRANSITIONING FIREFIGHTING FOAMS Organizations around the world prioritize having adequate fire protection
More informationAPPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview
Overview Modern combustion (or gas) turbine packages typically include an axial compressor, a combustion section and a turbine. Both compressor and turbine sections consist of one or more sets of fixed
More informationFire and Gas Mapping- Updates to ISA84 TR7
Fire and Gas Mapping- Updates to ISA84 TR7 Murtaza I. Gandhi, P.E. BakerRisk BAKER ENGINEERING AND RISK CONSULTANTS, INC. 2017 Baker Engineering and Risk Consultants, Inc. Agenda Introduction to Fire and
More informationBowties in process safety auditing
Bowties in process safety auditing Mireille Busque - ERM Insert then choose Picture select your picture. Right click your picture and Send to back. Copyright 2015 by ERM Worldwide Limited and/or its affiliates
More informationTetraTek, Inc. Regulatory. Compliance. Emergency Response. Nuclear Facility Compliance. Compliance. Fire Protection.
has in-depth experience with support services throughout the DOE Complex, Power and Enrichment Fuel Cycle industries. With hands-on experience and our policy-making process in the development of National
More informationEnclosure 4- RISK ASSESSMENT
Enclosure 4- RISK ASSESSMENT RISK ASSESSMENT Risk is a potential that a chosen action or activity will lead to a loss of human or property. Risk assessment is a step for Risk Management. Risk assessment
More informationrisk management and assessment for business Lessons Learned from Real World Application of Bow-tie Method 2010 International Symposium
risk management and assessment for business Risktec Solutions Lessons Learned from Real World Application of Bow-tie Method 2010 International Symposium BEYOND REGULATORY COMPLIANCE, MAKING SAFETY SECOND
More informationMartin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY
Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY Agenda 1 Challenges in the Process Industry International codes and standards F&G in an industrial Facility Honeywell s industrial F&G
More informationBowties in process safety auditing
Bowties in process safety auditing Mireille Busque - ERM Insert then choose Picture select your picture. Right click your picture and Send to back. May 9, 2017 Copyright 2015 by ERM Worldwide Limited and/or
More informationAGT 1 Confined Space. Authorised Gas Tester 1. Scienco Limited. Authorised Gas Tester 1 1
Scienco Limited AGT 1 Confined Space Authorised Gas Tester 1 Instructor: Gary Taylor E-Mail: gary@scienco.com Phone: +44 117 971 0001 Office: 10 Chapel Way, Bristol UK BS4 4EU Office Hours: 08:30 to 17:00
More informationPROFILE. industrial services rental trading
PROFILE industrial services rental trading Introduction Power Corp General Trading & Contracting Company W.L.L. is incorporated by technocrats having vast experience in Engineering and Construction field
More informationTABLE OF CONTENTS Part 6 Legal Basis for Fire Safety Planning... 2
TABLE OF CONTENTS Part 6 Legal Basis for Fire Safety Planning... 2 6.1] GENERAL... 2 6.2] EXCERPTS FROM 2012 BC FIRE CODE PART 2 BUILDING AND OCCUPANT FIRE SAFETY... 3 6.3] EXCERPTS FROM 2012 BC FIRE CODE
More informationAlarm Management Services
Alarm Management Services Know and improve alarm performance Integrate compeletely with almost any control system Increase operator efficiency Comply with regulatory and industry standards The Value of
More informationNEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION REQUIREMENTS
Mandatory Fire Safety Instruction Reference A: Reference B: NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION REQUIREMENTS Approved Document B Fire Safety
More informationFIRE HAZARD ASSESSMENT IN SUPPORTING FIRE PROTECTION SYSTEM DESIGN OF A CHEMICAL PROCESS FACILITY ABSTRACT
FIRE HAZARD ASSESSMENT IN SUPPORTING FIRE PROTECTION SYSTEM DESIGN OF A CHEMICAL PROCESS FACILITY Ali Pezeshk, Joseph Chang, Dwight Hunt, and Peter Jahn Parsons Infrastructure & Technology Group, Inc.
More informationCAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS
RANDAL BROWN & ASSOCIATES ENGINEERING LTD. CONSULTING ENGINEERS LIFE SAFETY & FIRE PROTECTION 105 6 LANSING SQUARE TORONTO, ONTARIO CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY
More informationPerformance and Cost Data. fire services
Performance and Cost Data fire services 195 PERFORMANCE MEASURES FOR FIRE SERVICES SERVICE DEFINITION Fire Services refers to the activities and programs relating to the prevention and suppression of fires,
More informationG- CORP SOLUTION. (SAFETY.CONSULTANCY.MANAGEMENT) ISO 9001 :2015 Certified.
G- CORP SOLUTION (SAFETY.CONSULTANCY.MANAGEMENT) ISO 9001 :2015 Certified www.gcorpsolution.com About us G-Corp Solution was formed in 2016, it is an ISO 9001 : 2015 certified, an MSME registered & membership
More informationMission. Vision. To set the standard for excellence and innovation in public safety. Department Description
Fire FIRE Mission The mission of the Fire Department is to ensure the health, safety, and well-being of our community by providing a wide range of innovative services. Vision To set the standard for excellence
More informationRisk and Fire Safety: Fire safety integration in potentially hazardous process industry. Engineers Australia Society of Fire Safety.
Risk and Fire Safety: Fire safety integration in potentially hazardous process industry Engineers Australia Society of Fire Safety Agenda 2 Background Fire Safety Study in the planning process Aim and
More informationApplying Functional Safety Engineering Technique to Optimize Defensive Fire Protection Strategy
Applying Functional Safety Engineering Technique to Optimize Defensive Fire Protection Strategy 66 th Canadian Chemical Engineering Conference October 19 th, 2016 Presented by Sam Sanati, P.Eng, FS Eng.
More informationIntegrating Fire and Gas Safety with Process Control Systems:
WHITE PAPER Integrating Fire and Gas Safety with Process Control Systems: Why, What and How If a fire, smoke or gas leak is detected in an industrial facility, prescriptive actions must be taken by the
More informationFIRE PROTECTION PROGRAM
Fire Protection Program Page 1 of 13 FIRE PROTECTION PROGRAM 1.0 Objective The objective of this performance assessment is to evaluate the effectiveness of the laboratory's fire protection program as implemented
More informationPREVENTION, PROTECTION, ROAD SAFETY
Learning and Development Managers Conference, 26 th April 2013 Firefighting in, and Protecting, the Built Environment Peter O Reilly Director of Prevention and Protection Greater Manchester Fire and Rescue
More informationF&G detection system for LNG plants
LNG PLANT F&G detection system for LNG plants The historical safety record for the LNG industry is strong. Engineering, installation and lifetime use takes into account the well known hazards of such an
More informationTOXIC AND FLAMMABLE GAS CLOUD DETECTORS LAYOUT OPTIMIZATION USING CFD
Introduction to the case Gas detectors are commonly installed in process facilities to automatically alarm and trigger safety measures in response to hazardous leaks. Without effective leak detection,
More informationCase Study. INTEGRATING Fire & GAS SAFETY WITH PROCESS CONTROL SYSTEMS
INTEGRATING Fire & GAS SAFETY WITH PROCESS CONTROL SYSTEMS INTEGRATING Fire & GAS SAFETY WITH PROCESS CONTROL SYSTEMS If a fire, smoke or gas leak is detected in an industrial facility, prescriptive actions
More informationMODULAR INTEGRATION OF PROCESS EQUIPMENT PACKAGES FOR OIL AND GAS FACILITIES
MODULAR INTEGRATION OF PROCESS EQUIPMENT PACKAGES FOR OIL AND GAS FACILITIES Copyright Material PCIC Europe Paper No. PCIC Europe LO-70 Allan Bozek EngWorks, Inc. 1620 49 th Avenue, SW Calgary, AB T2T
More informationFIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre
FIRE SAFETY POLICY LEEDS METHODIST MISSION Oxford Place Centre P a g e 2 8 Version Draft 1 Name of responsible (ratifying) committee Leeds Methodist Mission Council Date ratified Document Manager (job
More informationObjectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts
Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts Guy R. Colonna, PE Division Manager, NFPA Combustible Dust Symposium Detroit, MI September 20, 2011 1 Objectives
More informationFire Safety Strategy
SH HS 02 Summary: Keywords (minimum of 5): (To assist policy search engine) Target Audience: The aim of this strategy is the provision and maintenance of a safe environment for all staff, visitors and
More informationWHAT IS FIRE DISASTER? Fire Disaster is an occurrence or an incident of such magnitude which creates a situation in which the normal life is suddenly
TOPIC : FIRE DISASTER MANAGEMENT PRESENTED BY :- AMALENDU BANERJEE, DIVISIONAL OFFICER, WBFES WHAT IS FIRE DISASTER? Fire Disaster is an occurrence or an incident of such magnitude which creates a situation
More informationEASTERN ARIZONA COLLEGE Fire Department Operations II
EASTERN ARIZONA COLLEGE Fire Department Operations II Course Design 2015-2016 Course Information Division Allied Health Course Number FSC 102 Title Fire Department Operations II Credits 5 Developed by
More informationExecutive Summary of Qualifications
Executive Summary of Qualifications is a Veteran-Owned Small Business operating since 1995. is Native American owned and is comprised of experienced fire protection/safety engineers and technical staff,
More informationProtective & Marine Coatings Europe, Middle East, Africa & India
Protective & Marine Coatings Europe, Middle East, Africa & India FIRETEX M90 Series Hydrocarbon passive fire and cyrogenic spill protection solutions for oil & gas industries INTUMESCENT PASSIVE FIRE PROTECTION
More informationPrereq: FOD 131 or Instructor Permission
FOD 101--Required Fire Officer I: This course is an introduction to a fire officer s duties. The content includes report writing, diversity issues, work-place safety, decision-making, quality assurance,
More informationFire Prevention Plan Program
Fire Prevention Plan Program Effective Date: Revision #: Reference Standard Purpose Occupational Safety and Health Administration (OSHA) standard, 29 CFR 1910.39 Subpart E, Fire Prevention Plan This procedure
More informationReleasing Systems. Rob Mennie Senior Consultant Gage-Babcock & Associates Ltd.
Releasing Systems Rob Mennie Senior Consultant Gage-Babcock & Associates Ltd. Releasing Systems What is a releasing system? System designed to detect a fire Causes release of an extinguishing system in
More informationCase Study. Selecting fire and gas detectors for harsh and remote locations. INSTRUMENTATION
Selecting fire and gas detectors for harsh and remote locations Liquid natural gas (LNG) facilities in Y the frozen Russian Arctic. Drilling platforms in the swells of the North Sea. Pipelines that cross
More informationProcess Hazard Analysis Facility Siting Checklist
Process Hazard Analysis Facility Siting Checklist Facility: Date: Team Members: Note: For compliance, OSHA expects specific justification for each individual situation/condition. GENERAL CONSIDERATIONS
More informationTHE INITIATES PLC (TIP)
THE INITIATES PLC (TIP) THERMALDESORPTION SERVICES THE INITIATES PLC TDU, Incinerator, Cleaning & Decontamination, E-waste Services Our Culture: Mission; vision; business core values OUR MISSION: To facilitate
More informationResearch Needs for the Fire Safety Engineering Profession
Research Needs for the Fire Safety Engineering Profession Note: Items highlighted in RED are identified as the highest priority for each thread. Items highlighted in BOLD are identified as the highest
More informationPractical Methods for Process Safety Management
Practical Methods for Process Safety Management Putting Process Safety Management At The Heart Of Our Lives Canadian Chemical Engineering Conference 2006 October 18, 2006 CSChE Conference 2006 Quote Concern
More informationFLACS-Risk Unique 3D risk modelling software. FLACS-Risk: Product presentation FLUG May 2016
FLACS-Risk Unique 3D risk modelling software Outline FLACS-Risk Overview Motivation for developing FLACS-Risk Features of FLACS-Risk v1.0 Development process and timeline Possible future added modules
More informationBranch Fire Rescue Services
Branch Fire Rescue Services Introduction Through the protection of life, property and the environment, Fire Rescue Services strives to improve the livability of all Edmontonians. The provision of internationally-recognized
More informationFire Protection Regulatory Approach for Nuclear Power Plants in Canada
Fire Protection Regulatory Approach for Nuclear Power Plants in Canada IAEA Technical Meeting on Fire Protection Approaches and Experiences of Nuclear Power Plant 27-29 May 2015 I. Bolliger, A. Bounagui,
More informationEMERGENCY PREPAREDNESS & RESPONSE PROCEDURE
1 of 12 2 of 12 CONTENTS 1.0 OBJECTIVES...3 2.0 SCOPE...3 3.0 DEFINITION OF TERMS...3 4.0 RESPONSIBILITIES & AUTHORITIES...4 5.0...4 5.1 Emergency Scenario Identification...4 5.2 Emergency Response Team...4
More informationConducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches
Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches Pulp & Paper Safety Association Safety & Health Conference June 18, 2018 Mike Snyder PE CSP CFPS Executive Vice President,
More informationEvaluation and Compliance with Facility Siting Regulations in the US API RP 752 / 753 / 756
Evaluation and Compliance with Facility Siting Regulations in the US API RP 752 / 753 / 756 Presented by Gary Fitzgerald Director San Antonio, Texas U.S.A. Overview Safety Moment Introduction to Facility
More informationAnswer: B Objective: NFPA 472, (c), 4.2.3, 5.2.3(1); Level: Awareness, Operations Subject: Introduction; Chapter 1; Page 5
Chapter 1 Multiple Choice 1. The U.S. Department of Transportation s definition of hazardous materials specifies three entities against which a hazardous material poses an unreasonable risk. Which is one
More informationGulf Industrial Systems Co. Fire, Safety & Security Systems
Gulf Industrial Systems Co. Fire, Safety & Security Systems To a Controlled, Safer & Secured Future 2 Introduction Gulf Industrial Systems Company (GISCO) is a market leader in Integrated Fire-Safety and
More information26 June 2001 GUIDELINES ON ALTERNATIVE DESIGN AND ARRANGEMENTS FOR FIRE SAFETY
INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 020 7735 7611 Fax: 020 7587 3210 Telex: 23588 IMOLDN G IMO E Ref. T4/4.01 MSC/Circ.1002 26 June 2001 GUIDELINES ON ALTERNATIVE
More informationCHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS
CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS 61G15-32.001 61G15-32.002 61G15-32.003 61G15-32.004 61G15-32.005 61G15-32.006 61G15-32.007
More information4.13 Security and System Safety
4.13 4.13.1 Introduction This section describes the affected environment and environmental consequences related to security and system safety from operations of the NEPA Alternatives. Information regarding
More informationFire protection of emergency electrical devices: effect on the level of risk a case study of a rail tunnel
Safety and Security Engineering VI 73 Fire protection of emergency electrical devices: effect on the level of risk a case study of a rail tunnel M. Lombardi & G. Rossi Dipartimento di Ingegneria Chimica
More informationEMERGENCY PREPAREDNESS - POLLUTION INCIDENT RESPONSE PROGRAM
Page: 1 of 12 EMERGENCY PREPAREDNESS - POLLUTION INCIDENT RESPONSE PROGRAM TABLE OF CONTENTS 1. PURPOSE... 2 2. SCOPE... 2 3. REFERENCES... 2 4. DEFINITIONS... 3 5. RESPONSIBILITIES... 4 NOTE: LICENCE
More informationJournal of Faculty of Engineering & Technology
JFET 21(3) (2014) 62-69 Journal of Faculty of Engineering & Technology Journal homepage: www.pu.edu.pk/journals/index.php/jfet/index Fire and Their Mitigation Efforts in Gas Processing Facilities M.K.
More informationCOMBUSTIBLE DUST HAZARD MITIGATION
COMBUSTIBLE DUST HAZARD MITIGATION February 2014 GUIDE FOR FRONT LINE SUPERVISORS AND MANAGEMENT TABLE OF CONTENTS P a g e 1 A] Combustible Dust Hazard Mitigation... 4 A.1] Why Are We Here?... 4 A.2]
More informationRISK ASSESSMENT REPORT
RISK ASSESSMENT REPORT FOR PROPOSED EXPANSION OF BULK DRUG UNIT WITH CHANGE IN CAPACITY OF EXISTING CAPACITY FROM 3376.4 TPA TO 5783.84 TPA AT Plot no. A-l/ A, A-l/B, A-1/C, A-2/B, A-2/C, A-2/D, C8-3/C,
More informationStandoff CWA/TIC Detection. Innovation with Integrity. Toxic Gas/Vapour Threat Mitigation RAPIDplus CBRNE
Standoff CWA/TIC Detection Toxic Gas/Vapour Threat Mitigation RAPIDplus Innovation with Integrity CBRNE Choose Innovation Choose Bruker Toxic Gas Threat Mitigation: RAPIDplus Bruker is recognised as the
More informationDate Issued: December 14, 2017 Revision: 2.1
2.1 1. Introduction A is implemented to ensure the fire safety of building occupants or a building area when the Fire Alarm System or a Fire Protection System has been temporarily disabled due to malfunction,
More informationContents. xiii. 4. PHYSICAL PROPERTIES OF HYDROCARBONS General Alkene Series... 28
Contents 1. INTRODUCI'ION... 1 Historical Background... 2 Legal Influences... 4 Hazards and Their Prevention... 4 Systems Approach... 5 Fire Protection Engineering Role... 5 Risk Management and Insurance...
More informationFire. This policy applies to all members of our school community, including those within the EYFS setting.
Fire Contents Pages Policy Statement 1 Policy 1-3 Fire Procedures 3-4 Out of Hours 4 Visitors 4 Fire Prevention Measures 5-6 Fire Safety Checks and Records 6-7 All Employees should 7 Risk Assessment on
More informationLakanal House inquest: Statement from the Fire Sector Federation
Lakanal House inquest: Statement from the Fire Sector Federation The Fire Sector Federation (FSF) wishes to express profound sadness for the tragic loss of life that occurred at Lakanal House on the 3
More informationLata Mishra Bhabha Atomic Research Centre, INDIA
Lata Mishra Bhabha Atomic Research Centre, INDIA Outline of presentation Legal & Regulatory provisions / requirements Safety criteria & Safety objectives PIE s Safety & Seismic categorization Safety provisions
More informationProduct Supply, Hire & Service. Complete Safety Solutions for the Oil, Gas, Marine & Energy Industries. Safer.Smarter.Tyco.
Product Supply, Hire & Service Complete Safety Solutions for the Oil, Gas, Marine & Energy Industries Safer.Smarter.Tyco. Tyco has designed and developed a wide range of internationally approved solutions
More informationDomino Effects and Storage Sites of Propane in the Netherlands
Domino Effects and Storage Sites of Propane in the Netherlands Soedesh Mahesh Workshop Domino Effects in the Process Industry Bologna, Italy April 16-17, 2014 Content 1. Introduction 2. Guidelines to prevent
More informationEMERGENCY PREPAREDNESS - POLLUTION INCIDENT RESPONSE PROGRAM
Manager Page: 1 of 12 EMERGENCY PREPAREDNESS - POLLUTION INCIDENT RESPONSE PROGRAM TABLE OF CONTENTS 1. PURPOSE... 2 2. SCOPE... 2 3. REFERENCES... 2 4. DEFINITIONS... 3 5. RESPONSIBILITIES... 4 NOTE:
More informationICHEME SYMPOSIUM SERIES NO. 144 A METHODOLOGY FOR ASSESSING AND MINIMISING THE RISKS ASSOCIATED WITH FIREWATER RUN-OFF ON OLDER MANUFACTURING PLANTS
A METHODOLOGY FOR ASSESSING AND MINIMISING THE RISKS ASSOCIATED WITH FIREWATER RUN-OFF ON OLDER MANUFACTURING PLANTS Christopher J, Beale, Ciba Speciality Chemicals Pic, Water Treatments Division, PO Box
More informationEQUIVALENT INITIAL FIRE SAFETY ASSESSMENT
EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT Factory Plot # 33-36 Sector # 07, Chittagong Chittagong Chittagong 08 Jun 2014 The Alliance for Worker Safety Page 1/18 08 Jun 2014 Introduction to the Report
More informationSelecting fire and gas detectors for extreme environments
Fire & gas detection 21 Selecting fire and gas detectors for extreme environments Liquid natural gas (LNG) facilities in the frozen Russian Arctic. Drilling platforms in the swells of the North Sea. Pipelines
More informationWater Mist v Sprinklers
Water Mist v Sprinklers 15 th November 2018 Gary Howe EngTech FIFireE MIFPO Senior Fire Protection Engineer Zurich Risk Engineering Photo source: Stuart Lloyd, Zurich Zurich Fire Protection BS8489 FIA
More informationHealth and Safety Documents in connection with offshore oil and gas operations
Health and Safety Documents in connection with offshore oil and gas operations DWEA guideline 65.1.13 January 2017 The most important rules on Health and Safety Documents for installations with connected
More informationDRAFT REGULATORY GUIDE DG-1069 FIRE PROTECTION PROGRAM FOR NUCLEAR POWER PLANTS DURING DECOMMISSIONING AND PERMANENT SHUTDOWN
123-0083.htm at ruleforum.llnl.gov Page 1 of 27 This regulatory guide is being issued in draft form to involve the public in the early stages of the development of a regulatory position in this area. It
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61511-3 First edition 2003-03 Functional safety Safety instrumented systems for the process industry sector Part 3: Guidance for the determination of the required safety integrity
More informationSelecting fire and gas detectors for harsh and remote locations
Selecting fire and gas detectors for harsh and remote locations Liquid natural gas (LNG) facilities in the frozen Russian Arctic. Drilling platforms in the swells of the North Sea. Pipelines that cross
More informationINCIDENT TYPE: Structure Fire Fire in mobile property used as a fixed structure
INCIDENT TYPE: Structure Fire 110 Structure fire, other 111 Building fire 112 Fires in structure other than in a building 113 Cooking fire, confined to container 114 Chimney or flue fire, confined to chimney
More informationBuilding Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems
Building Standards Division Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems Crown Copyright 2015 Produced by the Buildings Standards Division February 2015 Version
More informationMarine Fire safety for the ship industry
Marine Fire safety for the ship industry This is Firesafe Energy We offer a wide range of fire protection solutions for the marine sector. We have documented solutions for both newbuilding, maintenance
More informationProcess Control PIP PCEA001 Fixed Gas Detection Guidelines
November 2015 Process Control PIP PCEA001 PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice has been prepared from the technical
More informationStatue of Liberty: A Risk Analysis
Statue of Liberty: A Risk Analysis Bruce Campbell, FSFPE VP DOE Services National Park Service Agenda Overview of Project Scope Evaluation Steps Task 1 Code Analysis Task 2 Fire Modeling Task 3 Egress
More informationFire prevention and protection
Fire prevention and protection The Fire Service College With over 40 years experience, the Fire Service College is a leading organisation for fire prevention, protection and response, providing assessed,
More informationMSA Flame & Gas Mapping
MSA Fixed Gas & Flame Detection Flame & Gas Mapping Solutions MSA Flame & Gas Mapping Because every life has a purpose... MSA Flame & Gas Mapping Why Perform Flame & Gas Mapping? Fixed flame and gas detection
More informationBranch Fire Rescue Services
Introduction Fire Rescue Services serves to protect the lives, properties and environment of citizens within our community by providing excellence in services and public safety. Edmonton Fire Rescue Services
More informationLYHA Fire Safety Policy
LYHA Fire Safety Policy Introduction This Fire Safety Policy shows our approach to Fire Safety in the work place and in our homes. It identifies our approach to Fire Safety in: The workplace Flats with
More informationTable OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS
901.6 Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective.
More informationThe investigation of accidents and incidents in complex railway tunnel systems
The investigation of accidents and incidents in complex railway tunnel systems Some background The Rail Accident Investigation Branch (RAIB) has investigated two fires involving freight shuttles in the
More informationJoint Responsibility for Health and Safety Internal Guidance for Members and other occupiers of the Scottish Parliament Campus.
To: Leadership Group From: Jake Fenton Extension: 86917 Date: 17/5/12 Dear Colleague, S. Joint Responsibility for Health and Safety Internal Guidance for Members and other occupiers of the Scottish Parliament
More informationProtect your people, assets and environment while ensuring operational performance.
Fire and Gas Solutions Protect your people, assets and environment while ensuring operational performance. Honeywell Capabilities Gas Detectors Flame Detectors Fire Detectors Fire Alarm Panels Fire Suppression
More informationJohnson Controls Security Solutions for Oil and Gas
Johnson Controls Security Solutions for Oil and Gas Johnson Controls are a global leader in providing complete life safety & asset integrity solutions to the oil, gas, and marine industries. For more than
More informationSpecialists in Tunnel Fire Protection
Specialists in Tunnel Fire Protection 00-M-0003-A Underground transport facilities are sensitive links in the economic chain that carry thousands of people and tons of goods every day and they are increasingly
More informationCAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning
CAN/ULC S1001-11 Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning Presentation To: Canadian Fire Alarm Association (CFAA) National Capital Region
More information