ELECTRICAL EXISTING CONDITIONS AND DESIGN ANALYSIS

Size: px
Start display at page:

Download "ELECTRICAL EXISTING CONDITIONS AND DESIGN ANALYSIS"

Transcription

1 Executive Summary ELECTRICAL EXISTING CONDITIONS AND DESIGN ANALYSIS Sara Lappano Ltg./Elec. Corron Cultural Center Middletown, VA Faculty Advisor: Dr. Moeck As in the prior lighting technical assignment, the delay in design for this building made it impossible to conduct a detailed electrical analysis of the systems simply because they have not been designed yet. A single line diagram and mechanical schedule from a similar theater project were available, so these were used as a reference for what the actual design will be. Because there are no panelboard schedules showing how equipment and spaces are grouped together, example calculations were performed in lieu of actual comparisons to the existing design.

2 ELECTRICAL EXISTING CONDITIONS AND DESIGN ANALYSIS Sara Lappano Ltg./Elec. Corron Cultural Center Middletown, VA Faculty Advisor: Dr. Moeck Single Line Diagram: See attached. The single line diagram given in this report is a system similar to the one that is being designed. However, it is not the actual single line diagram for the project. One noticeable difference is that the power service is being supplied at 34.5kV rather than the 12.5kV that is actually being used. Despite small differences like this, the layout of the system is similar to the one being designed. System Type: Radial: All building power is served through one primary feeder and one transformer. Building Utilization Voltage: 208/120 V, 3 phase, 4 wire Transformer Configuration: Transformer provided by the power company, rated at 12.5kV-208Y/120V. No further information available about it at this time. Emergency Power System: Motor generator rated at 120Y/208V, 3 Ф, 4 wire, 125 kw. The generator feeds main elevator, exhaust fan-1, emergency building lighting and power. Overcurrent Protective Devices: Circuit Breakers Location of Switchgear, Panelboards, and Motor Control Center: Exterior to the Building: Power company service transformer: 12.5kV-208Y/120VAC Power company kwh meter (by power company) Main Electrical Room (Basement) contains: Main service switchboard: 120/208V, 3 Ф, 4 wire, 4000 A, 100,000 AIC All circuit breakers for the building Isolation transformer providing clean power for computers Motor Control Center Power company meter (by power company) Digital circuit meter (by owner) Shunt trip connected to emergency power disconnect on 1 st floor Transient voltage surge suppressor Automatic transfer switch: 208V, 3 Ф, 4 pole, 400 A Backstage Electrical Room (1 st Floor): Contains four panelboards, not yet specified what these serve. Judging by where it is located, I would assume that it serves the backstage storage area, loading dock, laundry, and dressing rooms.

3 Lobby Area Electrical Room (1 st Floor): Contains two panelboards, not yet specified what these serve. Assume that they serve the pantry, lobby, vestibule, art gallery, manager s office, and ticket office. Dimmer Rack Room (2 nd Floor, Rear): Contains two panelboards (as shown at this time) serving all the dimmable stage lights and the house lights. Classroom Area Electrical Room (2 nd Floor): Contains three panelboards, appearing to serve classrooms, pantry, lounge, and workroom. Typical Lighting Systems and Operating Voltage: Fluorescent using 120V, Incandescent in theater area using 120V, low voltage step lighting using 12V. Power Factor Correction: None Important Design Requirements: Info on Lamps, Ballasts i.e. input watts, operating voltage, current, power factor Fixture Name 2x4 Parabolic Louver Location Classroom Lamp Type 4 Fluor. T8 (3) Lamp Ballast # Watts 32 W Adv# RCN- 3S32-SC Ballast Power Input Operating Current Factor Factor Watts Voltage W 120V.78 A 8 chalkbd washer Classroom 4 Fluor. T8 (2) Pendant Theater PAR38 Downlight Incand. Step Light Theater Tung. Halogen 32 W Adv# RCN W 120V.49 A 2M32-MC 250W n/a 250W 120V 2.08 A 20W n/a 20W 12V (integral xfmr) 1.67 A Wall Sconce Theater Incand. 100W n/a 100W 120V 0.833A Work Light Above 4 Fluor. 32W Adv# RCN V 0.49 catwalks T8 (2) 2M32-MC Recessed Circ. Dwnlt. Lobby CFL Tri- Tube 26W W 120V 0.24 Adv# ICF- 2S26-H1- LD@120 Bollard Exterior M.H. 100W Sylv# W 120V Pole Light Exterior M.H. 100W Sylv# W 120V Recessed Exterior PAR38 100W Sylv# W 120V Circ. Dwnlt. Canopy M.H. Wallwash Exterior Façade M.H. 100W Sylv# W 120V 0.933

4 Mechanical Equipment: Note: These mechanical systems are not the actual design for the building, but are examples taken from another similar project. Because the actual mechanical equipment has not been selected, the panelboard sizing that corresponds to the information below is not available. Type of Equipment HP Volts/Hertz/Phase AHU n/a AHU-2 11 n/a AHU n/a AHU-4 35 n/a AHU /60/1 AHU /60/1 CWP /60 CWP /60 HWP /60 HWP /60 EF /60 EF /60 EF /60 EF /60 Chiller 330 tons, min. D.E. fuse: /?/3 Boiler /60 Boiler /60 Boiler /60 NEC Building Design Load: See attached excel sheet. Because no panelboard schedules are available, it is impossible to know how loads were grouped together. Also, the NEC does not provide information about stage lighting loads, so only the house lighting load was calculated. Overall, the calculated lighting loads are far below what they will actually be in the theater area. Utility Rate Structure:

5

LIGHTING EXISTING CONDITIONS SUMMARY EXECUTIVE SUMMARY Sara Lappano Ltg./Elec. Corron Cultural Center Middletown, VA

LIGHTING EXISTING CONDITIONS SUMMARY EXECUTIVE SUMMARY Sara Lappano Ltg./Elec. Corron Cultural Center Middletown, VA LIGHTING EXISTING CONDITIONS SUMMARY EXECUTIVE SUMMARY Sara Lappano Ltg./Elec. Corron Cultural Center Middletown, VA 11.4.2002 Contained in this report is a summary of the lighting existing conditions

More information

Lord Stirling Community School Electrical Systems Existing Conditions & Building Load Summary Technical Assingment#2 Due October 26, 2004

Lord Stirling Community School Electrical Systems Existing Conditions & Building Load Summary Technical Assingment#2 Due October 26, 2004 Electrical Systems Existing Conditions & Building Load Summary Technical Assingment#2 Due October 26, 2004 Table of Content: Page 1 ~ Single Line Diagram 1 2 ~ Electrical System Narrative 2-3 3 ~ Lamp

More information

Building Electrical System Overview

Building Electrical System Overview Philip Mackey L/E Dr. Mistrick Holy Cross Hospital North Addition Silver Spring, MD 0/3/05 Building Electrical System Overview Executive Summary: The following report describes the existing emergency power

More information

Executive Summary. CNBC Global Headquarters Christine Cajilig

Executive Summary. CNBC Global Headquarters Christine Cajilig Executive Summary This report contains an analysis and description of the existing electrical distribution of the including the distribution type, emergency power, uninterruptible power system, over current

More information

Newark, Delaware Architectural Engineering Senior Thesis Portfolio. Electrical Analysis

Newark, Delaware Architectural Engineering Senior Thesis Portfolio. Electrical Analysis Electrical Analysis The AstroPower Headquarters building was constructed a few years ago to act as both a Headquarters and to be a display of what the product they manufacture can accomplish when put to

More information

Corbin Building. Technical Assignment 2. Matthew Trethaway Lighting/ Electrical AE 481W 10/26/2011 Advisor: Ted Dannerth

Corbin Building. Technical Assignment 2. Matthew Trethaway Lighting/ Electrical AE 481W 10/26/2011 Advisor: Ted Dannerth Corbin Building Technical Assignment 2 Matthew Trethaway Lighting/ Electrical AE 481W 10/26/2011 Advisor: Ted Dannerth 10/26/2011 Technical Report II 1 Executive Summary The following report is an overview

More information

Technical Report Two

Technical Report Two Technical Report Two Yale Sculpture Building Advisors: Ted Dannerth Richard Mistrick Date: October 31, 2006 Electrical Systems Existing Conditions and Building Load Summary Report Executive Summary: This

More information

Chandler City Hall Chandler, Arizona

Chandler City Hall Chandler, Arizona Chandler City Hall Chandler, Arizona AE481W: Architectural Engineering Senior Thesis Wednesday October 27 th, 2010 Stephanie Romanias Lighting/Electrical Faculty Consultant Dr. Kevin Houser/Professor Dannerth

More information

Electrical Systems Existing Conditions and Building Load Summary Report

Electrical Systems Existing Conditions and Building Load Summary Report The building was constructed a few years ago to act as both a Headquarters and to be a display of what the product they manufacture can accomplish when put to work. The building features both office and

More information

Electrical System (N) PANELBOARD "L1" VOLTAGE: 208/120 A, 3P :MAIN C/B PHASE: 3 A :BUSSING WIRE: 4 :MOUNTING

Electrical System (N) PANELBOARD L1 VOLTAGE: 208/120 A, 3P :MAIN C/B PHASE: 3 A :BUSSING WIRE: 4 :MOUNTING Electrical System After re-designing the lighting system for the children s computer, circulation and storytelling areas, the electrical system had to be redesigned as well. These are the new panel board

More information

Technical Report #2. Newseum and Freedom Forum Headquarters. Washington, D.C. Ryan Wise Lighting/Electrical Prof. Dannerth November 2, 2007

Technical Report #2. Newseum and Freedom Forum Headquarters. Washington, D.C. Ryan Wise Lighting/Electrical Prof. Dannerth November 2, 2007 Technical Report #2 Ryan Wise Lighting/Electrical Prof. Dannerth November 2, 2007 Newseum and Freedom Forum Headquarters Washington, D.C. Table of Contents Power Distribution Systems Executive Summary

More information

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School ELECTRICAL SYSTEMS ASSESSMENT Hanover High School ELECTRICAL DISTRIBUTION SYSTEM:?? The existing electrical service consists of an underground primary service originating at a utility pole on Cedar Street,

More information

Schematic Design Ideas for the Westlake Recreation Center. Presented by: Summer Padgett At Lutron Electronics On December 9, 2003

Schematic Design Ideas for the Westlake Recreation Center. Presented by: Summer Padgett At Lutron Electronics On December 9, 2003 Schematic Design Ideas for the Westlake Recreation Center Presented by: Summer Padgett At Lutron Electronics On December 9, 2003 The Westlake Recreation This facility serves as a park and recreation center

More information

Technical Assignment #2 Electrical Systems Existing Conditions & Building Load Summary

Technical Assignment #2 Electrical Systems Existing Conditions & Building Load Summary Technical Assignment #2 Electrical Systems Existing Conditions & Building Load Summary William H. Gates Hall Seattle, WA Katherine Jenkins Lighting/Electrical Option October 27, 2006 Faculty Advisor: Ted

More information

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA PART 1 - GENERAL 1.1 Background SECTION 26 00 10- ELECTRICAL DESIGN CRITERIA A. Brown University maintains it own campus electrical distribution system which serves the majority of the buildings and facilities

More information

Franklin Square Hospital Center

Franklin Square Hospital Center Franklin Square Hospital Center Baltimore, MD Thesis Proposal Cassandra Watson + Electrical Electrical Advisor Professor Dannerth Advisor Dr. Mistrick 16 December 2009 Table of Contents Executive Summary...

More information

Thesis Proposal. Brian Regan The Virginia Historical Society Building West Wing Addition RICHMOND, VIRGINIA

Thesis Proposal. Brian Regan The Virginia Historical Society Building West Wing Addition RICHMOND, VIRGINIA Thesis Proposal Brian Regan The Virginia Historical Society Building West Wing Addition RICHMOND, VIRGINIA New Addition s Functions Auditorium Entrances located on ground and basement floors Museum Art

More information

Technical II Report Electrical Systems

Technical II Report Electrical Systems Technical II Report Electrical Systems Kelly Chan Consultant: Prof T. Dannerth, P.E. Part A Drawings Drawings needed for single-line diagram EE1.01 title sheet (electrical drawings) EE2.09 penthouse/roof

More information

Lindsay Frederick. Lighting + Electrical. Ron Dodson Faculty Advisor. Native American Cultural Center Arizona. Technical Report 2

Lindsay Frederick. Lighting + Electrical. Ron Dodson Faculty Advisor. Native American Cultural Center Arizona. Technical Report 2 Lindsay Frederick Lighting + Electrical Ron Dodson Faculty Advisor Native American Cultural Center Arizona Technical Report 2 Native American Cultural Center Technical Report 2 p. 2 Executive Summary The

More information

Lighting Existing Conditions and Design Criteria Report Brian Regan Ltg./Elect. Virginia Historical Society 10/8/03

Lighting Existing Conditions and Design Criteria Report Brian Regan Ltg./Elect. Virginia Historical Society 10/8/03 Lighting Existing Conditions and Design Criteria Report Brian Regan Ltg./Elect. Virginia Historical Society 10/8/03 Executive Summary The existing lighting conditions and design criteria report describes

More information

Electrical Inspection Service & Distribution

Electrical Inspection Service & Distribution 0911 Distribution Panels & Switchgear Equipment, conduit, feeders, and grounding 480 Volt Switchboard: This switchboard contains the utility meter and two main, service, circuit breakers. One circuit breaker

More information

Surface Materials. Surface Material Reflectance. Acoustic Ceiling 80% Tile. Painted Gypsum 75% Wall Board. Vinyl Composition 32% Tile

Surface Materials. Surface Material Reflectance. Acoustic Ceiling 80% Tile. Painted Gypsum 75% Wall Board. Vinyl Composition 32% Tile Genetics Laboratory Space Description The Genetics Laboratory is located on the second floor of the laboratory building. The main functions of this space are as a learning and research area. There is a

More information

Overview. The Reading Room

Overview. The Reading Room Overview The library for is the largest space in the George E. Bello Center. This space not only houses all the school s books and reference material, but there are computer terminals set up for students

More information

TONY ESPOSITO LIGHTING/ELECTRICAL TECHNICAL REPORT II SEPTEMBER 15, 2011 HUNTER S POINT SOUTH INTERMEDIATE SCHOOL AND HIGH SCHOOL QUEENS, NY

TONY ESPOSITO LIGHTING/ELECTRICAL TECHNICAL REPORT II SEPTEMBER 15, 2011 HUNTER S POINT SOUTH INTERMEDIATE SCHOOL AND HIGH SCHOOL QUEENS, NY LIGHTING/ELECTRICAL TECHNICAL REPORT II SEPTEMBER 15, 2011 HUNTER S POINT SOUTH INTERMEDIATE SCHOOL AND HIGH SCHOOL QUEENS, NY 1 1A. POWER DISTRIBUTION SYSTEMS a. EXECUTIVE SUMMARY b. SUMMARY DESCRIPTION

More information

HARRY RANSOM HUMANITIES RESEARCH CENTER

HARRY RANSOM HUMANITIES RESEARCH CENTER HARRY RANSOM HUMANITIES RESEARCH CENTER Additions and Renovations MICHAEL ANTHONY LOMBARDI Lighting/Electrical Emphasis Dr. Richard Mistrick, Advisor The Pennsylvania State University HARRY RANSOM HUMANITIES

More information

University Park, PA. The Pennsylvania State University Architectural Engineering Lighting and Electrical Faculty Advisor: Dr.

University Park, PA. The Pennsylvania State University Architectural Engineering Lighting and Electrical Faculty Advisor: Dr. University Park, PA The Pennsylvania State University Architectural Engineering Lighting and Electrical Faculty Advisor: Dr. Martin Moeck A Building Overview The main spaces include: Convenience Store

More information

Oregon Non-Residential Building Energy Code

Oregon Non-Residential Building Energy Code Oregon Non-Residential Building Energy Code Interior Connected Lighting Power Requirements The requirements for interior lighting power are one of the most important sections of the Oregon Energy Code.

More information

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES 2.07 ELECTRICAL GENERAL DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES - 2.07 It is expected that the electrical design professional will conform to accepted good engineering design practices.

More information

LED Retrofit Lighting Rebate 2017 Rebate Application

LED Retrofit Lighting Rebate 2017 Rebate Application Commercial and Industrial LED Retrofit Lighting Rebate 2017 Rebate Application Business Member Information Connexus Energy 14601 Ramsey Blvd NW Ramsey, MN 55303 ConnexusEnergy.com 763.323.2600 Company

More information

* Peak kw is determined by the average kw load reduction occurring between 1PM and 4PM on weekdays during June, July and August.

* Peak kw is determined by the average kw load reduction occurring between 1PM and 4PM on weekdays during June, July and August. overview Summary of Services & Incentives Effective through March 31, 2014 Last updated April 1, 2013 business programs The goal of the Focus on Energy Business Programs is to help Wisconsin s non-residential

More information

Technical Report 2: Electrical Systems Existing Conditions and Building Load Summary Report. 100% Submission. Sherrerd Hall, Princeton University, NJ

Technical Report 2: Electrical Systems Existing Conditions and Building Load Summary Report. 100% Submission. Sherrerd Hall, Princeton University, NJ Technical Report 2: Electrical Systems Existing Conditions and Building Load Summary Report 100% Submission Sherrerd Hall, Princeton University, NJ Faculty Consultant: Ted Dannerth 4 November 2009 Table

More information

Business Customer Information. Account Number (9 digits) Account Holder Name Phone (As shown on your utility bill) Service Street Address

Business Customer Information. Account Number (9 digits) Account Holder Name Phone  (As shown on your utility bill) Service Street Address Commercial Lighting Rebate Application Please complete the application including existing and installed information. Application will be returned without valid purchase receipt/invoice or if equipment

More information

Lighting Existing Conditions and Design Criteria Report

Lighting Existing Conditions and Design Criteria Report page 1 of 19 Lighting Existing Conditions and Design Criteria Report The lighting in the includes very general lighting used in buildings with an office type setting. The fixture schedule for the Hall

More information

2017 Lighting Incentive

2017 Lighting Incentive Commercial & Industrial Retrofit 2017 Lighting Section A: CUSTOMER INFORMATION Customer Name Electric Account Number Rate Application Number Facility Address City State Zip Service Location Identification

More information

Advances in Non-Residential Lighting Technologies

Advances in Non-Residential Lighting Technologies Advances in Non-Residential Lighting Technologies CABEC conference San Diego, CA October 21, 2011 Steven Mesh, LC, IESNA Lighting Education & Design 140 Gardenside Drive, #304 San Francisco, CA 94131 415-516-8126

More information

Electrical Systems. Electrical Plans. Electrical Plans. Essential to ensure. National Electrical Code (NES) Consider electrical needs.

Electrical Systems. Electrical Plans. Electrical Plans. Essential to ensure. National Electrical Code (NES) Consider electrical needs. Electrical Systems Electrical Plans Essential to ensure Proper wiring National Electrical Code (NES) Electrical Plans Consider electrical needs Office equipment Lighting E t t i t t Entertainment systems

More information

Pacific Gas and Electric Company Product Changes

Pacific Gas and Electric Company Product Changes Pacific Gas and Electric Company 2013-2014 Product Changes Effective January 1, 2013, Pacific Gas and Electric Company (PG&E) has implemented a number of updates to its Business Rebates program, including

More information

Dorrance H. Hamilton Building

Dorrance H. Hamilton Building Dorrance H. Hamilton Building Josh Kreutzberger Penn State Architectural Engineering Technical Report 3 Advisor: Dr. Mistrick Site Overview Martin Building December 2006 Scott Library & Administrative

More information

Chang Liu Lighting + Electrical M.A.E./B.A.E. Integrated Degree. Technical Assignment 2 October 12, 2012 Faculty Consultants: Ron Dodson

Chang Liu Lighting + Electrical M.A.E./B.A.E. Integrated Degree. Technical Assignment 2 October 12, 2012 Faculty Consultants: Ron Dodson M.A.E./B.A.E. Integrated Degree Technical Assignment 2 October 12, 2012 Faculty Consultants: Ron Dodson Renzo Museum of American Art Executive Summary This report provides an analysis of the electrical

More information

Abella Digital Fade Dimmer

Abella Digital Fade Dimmer LUTRON ABELLA DIGITAL FADE DIMMER Abella Digital Fade Dimmer press on to favorite level; press off press twice for full on press, hold and release for gradual fade-to-off touch buttons to adjust light

More information

DUFFERIN-PEEL CATHOLIC DISTRICT SCHOOL BOARD

DUFFERIN-PEEL CATHOLIC DISTRICT SCHOOL BOARD DUFFERIN-PEEL CATHOLIC DISTRICT SCHOOL BOARD LIGHTING FIXTURES AND CIRCUITRY & SWITCHING SECONDARY SCHOOLS 1. GENERAL 1.1.1. Consultants MUST prepare a Summary of Fixtures which will include catalogue

More information

LED Retrofit Lighting Rebate 2018 Rebate Application

LED Retrofit Lighting Rebate 2018 Rebate Application Commercial and Industrial LED Retrofit Lighting Rebate 2018 Rebate Application Business Member Information Connexus Energy 14601 Ramsey Blvd NW Ramsey, MN 55303 ConnexusEnergy.com 763.323.2600 Company

More information

Note: The office/work area is not in the scope of the PER. Existing Condition

Note: The office/work area is not in the scope of the PER. Existing Condition ROBERT G. DASHIELL, JR., P.E., INC. Consulting Engineers 1225 West 26 th Street, Norfolk, Virginia 23508 (757) 623-5012 September 14, 2016 Draft Electrical Portion of the PER Petersburg Main Sanitary Sewage

More information

DIVISION 16 ELECTRICAL SYSTEMS

DIVISION 16 ELECTRICAL SYSTEMS DESIGN AND CONSTRUCTION STANDARDS DIVISION 16 DIVISION 16 Division 16 of the Carnegie Mellon University Design and Construction Standards Manual addresses the following requirements for electrical systems

More information

INVENTORY REPORT REPORT SUMMARY OPTIONAL ITEMS. 1 P a g e ASSOCIATION: SUNNYSIDE COURTS CONDO ASSOCIATION ADDRESS: 3047 N LINCOLN AVE

INVENTORY REPORT REPORT SUMMARY OPTIONAL ITEMS. 1 P a g e ASSOCIATION: SUNNYSIDE COURTS CONDO ASSOCIATION ADDRESS: 3047 N LINCOLN AVE INVENTORY REPORT ASSOCIATION: SUNNYSIDE COURTS CONDO ASSOCIATION ADDRESS: 3047 N LINCOLN AVE CREATION DATE: 12/1/2015 REPORT SUMMARY This document tracks the inventory of all fire safety equipment at the

More information

Currently, all electrical upgrades would be voluntary, but there are situations in which upgrades would be required.

Currently, all electrical upgrades would be voluntary, but there are situations in which upgrades would be required. Executive Summary The current electrical system is functional but requires some understanding in order to avoid overloading circuits. Certain outlets can be used for space heaters while others cannot and

More information

FIRE ALARM: BY OTHERS, IF REQUIRED.

FIRE ALARM: BY OTHERS, IF REQUIRED. x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. FLUORESCENT STRIP LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. WALL BRACKET FLUORESCENT

More information

Electrical Systems Existing Conditions and Building Load Summary Broadway Plaza, Rochester, MN. Appendix A

Electrical Systems Existing Conditions and Building Load Summary Broadway Plaza, Rochester, MN. Appendix A Appendix A Single Line Diagram Power Riser Diagram Dimming System Schematic Diagrams Dry-Type Transformer Schedule Primary Lamp and Ballast Table Mechanical Equipment Table Utility Rate Structure Breakdown

More information

FIRE ALARM: BY OTHERS, IF REQUIRED.

FIRE ALARM: BY OTHERS, IF REQUIRED. x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. CAPITAL LETTER DENOTES TYPE, LOWER CASE LETTER DENOTES SWITCH LEG. FLUORESCENT STRIP LIGHT FIXTURE,

More information

Lighting Retrofit Rebate

Lighting Retrofit Rebate Lighting Retrofit Rebate 2017 Rebate Application Elk River Municipal Utilities, PO Box 430, Elk River, MN 55330 Ph: 763-441-2020 Business Information Company name Billing address Installation address (if

More information

SUMMARY OF SERVICES & INCENTIVES

SUMMARY OF SERVICES & INCENTIVES BUSINESS PROGRAMS 2016 SUMMARY OF SERVICES & INCENTIVES Effective through December 31, 2016 Last updated February 1, 2016 EFFICIENCY INCENTIVES SUMMARY The Focus on Energy Business Programs offer both

More information

BASIC ELECTRICAL ENGINEERING FOR CE

BASIC ELECTRICAL ENGINEERING FOR CE EE24 BASIC ELECTRICAL ENGINEERING FOR CE LECTURE NO. B-2 Basic Electrical Code Provisions Codes/Standards/Organizations PEC Philippine Electrical Code NEC National Electrical Code IEEE - Institute of Electrical

More information

PANELBOARDS & BUILDING DISTRIBUTION

PANELBOARDS & BUILDING DISTRIBUTION 262416 PANELBOARDS & BUILDING DISTRIBUTION PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Distribution panelboards 2. Power panelboards B. Related Sections: 1.02 POLICY 1. CU Standard 260500, Basic

More information

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5 Page 1 of 5 1.0 GENERAL 1.1 Related UBC Guidelines.1 Section 27 05 05 Communication Rooms Design Guidelines 2.13 1.2 Coordination Requirements.1 UBC Energy & Water Services.2 UBC Building Operations Electrical

More information

The following narrative outlines a conceptual electrical Scope of Work for converting the Phase 2 TRW Building to an Exhibition Hall.

The following narrative outlines a conceptual electrical Scope of Work for converting the Phase 2 TRW Building to an Exhibition Hall. The following narrative outlines a conceptual electrical Scope of Work for converting the Phase 2 TRW Building to an Exhibition Hall. Demolition: The area of work shall be a complete gut ; removing all

More information

Lighting Summary - Interior

Lighting Summary - Interior Lighting Summary - Interior LTG-SUM Project Info Date: For Building Department Use Applicant Name: Applicant Address: Applicant Phone: Project Description F New building Addition Alteration Compliance

More information

Depth Work Part 1: Lighting Design

Depth Work Part 1: Lighting Design During the upcoming spring semester I will be investigating and redesigning some of the systems in Redifer Commons. This thesis study will be composed of three sections, which will all end up intertwining.

More information

Lindsey Beane. Executive Summary

Lindsey Beane. Executive Summary Executive Summary The purpose of this technical assignment is to compile lighting information and make an analysis about the existing spaces. This report will include a list of the equipment used, required

More information

PLATTEVILLE MIDDLE SCHOOL

PLATTEVILLE MIDDLE SCHOOL Architectural The building has aluminum clad wood awning windows in combination with aluminum fixed glass units. They appear to be exterior glazed with insulated glazing. See photo 2. Platteville Middle

More information

Business Energy Efficiency Incentives 2007

Business Energy Efficiency Incentives 2007 Business Energy Efficiency Incentives 2007 1 DSM s Energy & Environmental Impact since 1981 9,378,000,000 kwh 2 1 Year Round Savings on EnergyWise 2 Cars driven 12,000 Miles Progress Energy Growth Trend

More information

Schematic Design Proposal Presentation

Schematic Design Proposal Presentation Steven A. Neimeister 9 December 2003 Architectural Engineering 481W AstroPower Headquarters Newark, Delaware Lighting/Electrical Option Consultant: Dr. M. Moeck Introduction to AstroPower Welcome to AstroPower!

More information

Related Sections: TBD. Effective Date: January 1, 2016

Related Sections: TBD. Effective Date: January 1, 2016 Description: The purpose of the section is to highlight the current applicable UMCP Design Standards for the design, selection and, installation of lighting fixtures within buildings. Related Sections:

More information

NORTH CENTRAL MICHIGAN COLLEGE PETOSKEY CAMPUS. Facilities Conditions Assessment Mechanical And Electrical Petoskey, Michigan

NORTH CENTRAL MICHIGAN COLLEGE PETOSKEY CAMPUS. Facilities Conditions Assessment Mechanical And Electrical Petoskey, Michigan NORTH CENTRAL MICHIGAN COLLEGE PETOSKEY CAMPUS Facilities Conditions Assessment Mechanical And Electrical Petoskey, Michigan PBA Project No. 2014.0137.00 Prepared By: Wayne Kerbelis Terry Cleis September

More information

Division 26 ELECTRICAL TABLE OF CONTENTS

Division 26 ELECTRICAL TABLE OF CONTENTS Division 26 ELECTRICAL TABLE OF CONTENTS 26 1000 GENERAL... 33 A. CODE... 3 B. RELATED SECTIONS... 3 C. ABBREVIATIONS... 3 D. DEFINITIONS... 3 E. DRAWING REQUIREMENTS... 3 F. EQUIPMENT SERVICE ACCESS AND

More information

Lobby Lighting Design

Lobby Lighting Design Lobby Lighting Design The main lobby in Duques is hall is located on the first and second floor of the building. It is the main pathway in and out of the building for the more important spaces, such as

More information

ELECTRICAL Seminar. B A L A Consulting Engineers, Inc. Edward J. Lynch, PE Vice President, Electrical Department Manager.

ELECTRICAL Seminar. B A L A Consulting Engineers, Inc. Edward J. Lynch, PE Vice President, Electrical Department Manager. B A L A Consulting Engineers, Inc. PECO Line 13.2kV Incoming Service No. 1 Utility/Generator Medium Voltage Switchgear PECO Line 13.2kV Incoming Service No. 2 Unit Substation ELECTRICAL Seminar HVAC Equip.

More information

Renovate MCRC Facilities Great Lakes, IL

Renovate MCRC Facilities Great Lakes, IL 6. ENGINEERING SYSTEMS REQUIREMENTS D50 ELECTRICAL SYSTEM DESCRIPTION The electrical repair work includes the design and construction of the electrical distribution system for the B3200 Marine Corps Reserve

More information

Technical Report 2: Electrical Systems Criteria and Existing Conditions

Technical Report 2: Electrical Systems Criteria and Existing Conditions Technical Report 2: Electrical Systems Criteria and Existing Conditions Princeton Theological Seminary Library Princeton, NJ Stephanie Deckard Lighting Electrical Faculty Advisor Dr. Kevin Houser 10/12/2012

More information

LED Lighting: Technology Selection and System Commissioning Course Number: CXENERGY1519

LED Lighting: Technology Selection and System Commissioning Course Number: CXENERGY1519 AABC Commissioning Group AIA Provider Number: 50111116 LED Lighting: Technology Selection and System Commissioning Course Number: CXENERGY1519 Michael Chow, P.E., CxA, LEED AP BD+C, Metro CD Engineering

More information

Lobby Lighting Redesign

Lobby Lighting Redesign Lobby Lighting Redesign Description of Space The lobby is located on the first floor of the building. Upon entering the building through the curved façade that features large expanses of glass, one would

More information

Gathering Space. Function and Orientation. Space Characteristics Gregory Wolfe 2004 Senior Thesis Lighting / Electrical

Gathering Space. Function and Orientation. Space Characteristics Gregory Wolfe 2004 Senior Thesis Lighting / Electrical Gathering Space Function and Orientation The gathering space and reception area on the first floor is the first space you encounter upon entering the Westwood Community Church. As such, its purpose is

More information

ELECTRIC SERVICE EVALUATIONS ELECTRICAL / BOILER REPLACEMENTS. Clarkstown Central School District. June Arch Proj. #

ELECTRIC SERVICE EVALUATIONS ELECTRICAL / BOILER REPLACEMENTS. Clarkstown Central School District. June Arch Proj. # ELECTRICAL ELECTRIC SERVICE EVALUATIONS / BOILER REPLACEMENTS Clarkstown Central School District June 2015 CSArch Arch Proj. # 151-1501.00 151 Table of Contents SECTION 1 Executive Summary... 1 SECTION

More information

Lighting Depth Part 1: Exterior Space

Lighting Depth Part 1: Exterior Space Lighting Depth Part 1: Exterior Space Metaphor and Ideas: The first space of my lighting redesign is the front façade of the Recreation Center shown below. Metaphorically, I want the front porch to act

More information

Who is Iconic LED? Page 2. Phone:(337)

Who is Iconic LED? Page 2. Phone:(337) Who is Iconic LED? At Iconic LED our mission is to be an icon in the lighting industry by providing excellent customer service, and quality products through a traditional distribution model focused on

More information

NYC Department of Education

NYC Department of Education NYC Department of Education Building Assessment Survey 2017-2018 Asset: P.S. 135 - QUEENS, 207-11 89TH AVENUE, New York, 11427 Inspection Id Inspection Type Time In Last Edited EE : Electrical 2018-03-20

More information

Appendix B. Facilities Assessment Report

Appendix B. Facilities Assessment Report Mile Lane Army Reserve Center Redevelopment Plan September 2008 Appendix B Facilities Assessment Report RKG Associates, Inc. Mile Lane Army Reserve Base Middletown, CT MEP System Evaluation For RKG Associates

More information

University of California, San Diego Cal IT 2 Brian Smith. Schematic Design Presentation 06 December 2005

University of California, San Diego Cal IT 2 Brian Smith. Schematic Design Presentation 06 December 2005 University of California, San Diego Cal IT 2 Brian Smith Schematic Design Presentation 06 December 2005 Building Overview Location: University of California, San Diego Size: 220,000 s.f. Architect: NBBJ

More information

2018 Commercial Lighting Retrofit Rebate Program

2018 Commercial Lighting Retrofit Rebate Program 2018 Commercial Lighting Retrofit Rebate Program HOW TO APPLY 1. AMU provides energy efficiency rebates for the purchase and installation of qualifying lighting equipment. Additional lighting rebates,

More information

GARCIA GALUSKA DESOUSA Consulting Engineers

GARCIA GALUSKA DESOUSA Consulting Engineers L#57297 /Page 1/July 21, 2017 ELECTRICAL SYSTEMS NARRATIVE REPORT The following is the Electrical Systems narrative, which defines the scope of work and capacities of the Power and Lighting systems, as

More information

LIGHT LEVEL REQUIREMENTS MINIMUM ACCEPTABLE FOOT CANDLES

LIGHT LEVEL REQUIREMENTS MINIMUM ACCEPTABLE FOOT CANDLES LIGHT LEVEL REQUIREMENTS LOCATION Classrooms and instrumental areas- Study Halls, Lecture Rooms, Art Rooms, Offices, Libraries, Conference Rooms, Work Rooms, Shops, Laboratories and Secondary School Cafeterias.

More information

PSO Business Rebates Retrofit Lighting Technical Requirements

PSO Business Rebates Retrofit Lighting Technical Requirements PSO Business Rebates Retrofit Lighting General LED Requirements LED replacement and LED luminaires must be listed on the Design Lights Consortium (DLC) or ENERGY STAR Qualified Products List (QPL). DLC

More information

Mechanical Technical Report 1. ASHRAE Standard 62.1 Ventilation Compliance Evaluation

Mechanical Technical Report 1. ASHRAE Standard 62.1 Ventilation Compliance Evaluation Mechanical Technical Report 1 Standard 62.1 Ventilation Compliance Evaluation Lutheran Theological Seminary at Philadelphia The New Learning Center Prepared For: William P. Bahnfleth, Ph.D., P.E. Department

More information

Focus on Energy Business Programs Summary of Services and Incentives July 2009

Focus on Energy Business Programs Summary of Services and Incentives July 2009 Focus on Energy Business Programs Summary of Services and Incentives July 2009 OVERVIEW Focus on Energy Business Programs goals are to educate Wisconsin s farmers, businesses, industry, schools and local

More information

managing electricity at home atcoenergysense.com

managing electricity at home atcoenergysense.com managing electricity at home atcoenergysense.com Helping Yellowknifers make wise electricity choices Many of us don t realize the intricate processes behind generating, transmitting and distributing electricity,

More information

Element D Services Electrical

Element D Services Electrical PART 1 - GENERAL 1.01 OVERVIEW A. This Section includes design standards and requirements for electrical service and distribution. This is a design standard and is not intended to be used as a Specification.

More information

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. SECTION 262416 - PANELBOARDS PART 1 - GENERAL 1.1 SUMMARY A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. 1.2 PERFORMANCE REQUIREMENTS A. Seismic Performance:

More information

Lighting Existing Conditions and Design Criteria Report

Lighting Existing Conditions and Design Criteria Report Lighting Existing Conditions and Design Criteria Report EXECUTIVE SUMMARY This report will describe the existing lighting system of the specific spaces of my redesign the auditorium, the atrium, the outdoor

More information

Exterior Façade Lighting Design

Exterior Façade Lighting Design Exterior Façade Lighting Design Duques Hall is located on George Washington campus in downtown Washington DC. It is located amidst some other university buildings, however, the façade is very visible from

More information

Event 2 Appliances and LED lighting. Appliances Chris Knibbs LED lighting Andy Hannah Tea and biscuits after!

Event 2 Appliances and LED lighting. Appliances Chris Knibbs LED lighting Andy Hannah Tea and biscuits after! Event 2 Appliances and LED lighting Appliances Chris Knibbs LED lighting Andy Hannah Tea and biscuits after! Electrical Appliances Chris Knibbs ADAPT Energy Group Focus Waste Less Use Less (Use them less

More information

Senior Thesis Presentation

Senior Thesis Presentation Senior Thesis Presentation 5th Year Architectural Engineering Lighting/ Electrical Option Advisors: Dr. Mistrick & Prof. Dannerth Building Overview Size: 104, 000 square feet on 4 levels (3 stories above

More information

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. SECTION 262416 - PANELBOARDS PART 1 - GENERAL 1.1 SUMMARY A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. 1.2 PERFORMANCE REQUIREMENTS A. Seismic Performance:

More information

MOUNT PLEASANT MIDDLE SCHOOL HVAC. M-01 Heating Plant: M-02 Heating & Ventilating Systems: Livingston School District Mount Pleasant Middle School

MOUNT PLEASANT MIDDLE SCHOOL HVAC. M-01 Heating Plant: M-02 Heating & Ventilating Systems: Livingston School District Mount Pleasant Middle School MOUNT PLEASANT MIDDLE SCHOOL HVAC M-01 Heating Plant: The existing boilers have recently been upgraded. (3) steam boilers (8660 mbh each) manufactured by Weil- McLain have been installed. Newer hot water

More information

PG&E 2014 Title 24 Extension Products Products were extended through July 1, 2014

PG&E 2014 Title 24 Extension Products Products were extended through July 1, 2014 Midstream PG&E 2014 Title 24 Extension Products Products were extended through July 1, 2014 FAMILY CODE DESCRIPTION IMPACTED DISCONTINUATION LED Refrigerated Case Lights with Occupancy Sensors occupancy

More information

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL This Appendix (2000 IRC Appendix-L) is produced, copyrighted, and maintained by the National Fire Protection Association Association, all rights reserved. Use of this Appendix is pursuant to license with

More information

Eligible Prescriptive Measures List:

Eligible Prescriptive Measures List: Eligible Prescriptive Measures List: Business, Non-Profit, Institutional Energy Savings Program Products must meet the Canadian Certification Standards as outlined by the Standards Council Canada for product

More information

NYC Department of Education

NYC Department of Education NYC Department of Education Building Assessment Survey 2017-2018 Asset: P.S. 314 - BROOKLYN, 330 59 STREET, New York, 11220 Inspection Id Inspection Type Time In Last Edited EE : Electrical 2018-04-23

More information

Shepherd University Wellness Center AE 481 Revised Thesis Proposal

Shepherd University Wellness Center AE 481 Revised Thesis Proposal A E 481 REVISED THESIS PROPOSAL Shepherd University Wellness Center AE 481 Revised Thesis Proposal Shepherdstown, West Virginia Lighting/ Electrical Option Dr. Houser and Professor Dannerth March 24, 2011

More information

H107 Video Conference Room

H107 Video Conference Room Capacity: 20 persons White Board (1) Document Camera (1) Door (1) Network connections possible Layout: Seminar style with chairs and tables (moveable) Podium (1) Media Cart (1) Windows (4) Meets all ADA

More information

Café DUSON- Overview

Café DUSON- Overview Café DUSON- Overview Café DUSON is a study lounge with seating and tables to seat approximately 65 people in an area of about 1850 SF. The café is a double high space with full height windows on the North

More information

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Lighting. Basis of Design

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Lighting. Basis of Design Basis of Design This section applies to the design and installation of lighting systems. Design Criteria Select interior lighting to achieve initial system efficiencies greater than 64 lumens per watt.

More information