ASHRAE Illinois Chapter 2015 Excellence in Engineering Awards

Similar documents
The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

Madeira City Schools Madeira, Ohio. HVAC Assessment. December 2011 (Revised February 2012)

Andrea Borowski The Pennsylvania State University University Park, PA November 11, 2002 Consultant: Dr. Bahnfleth Technical Assignment M-3

FINAL REPORT INFRASTRUCTURE MASTER PLAN UPDATE. Harper College. Palatine, Illinois

MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION CONDITIONS FACILITIES MASTER PLAN MAY

Mechanical Redesign, Proposal Elizabeth C. Krauss Mechanical Option September 18, 2013

Submitted to. Texas A&M University at Galveston The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

SECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW...

Submitted to. Texas A&M University-Corpus Christi The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

GARCIA GALUSKA DESOUSA Consulting Engineers

4. OVERVIEW OF MECHANICAL SYSTEM

Urbana Free Library HVAC Analysis. Prepared for the Urbana Free Library. Prepared by Paul Boland, P.E., and Nathan Alderman, E.I.T.

TECHNICAL REPORT 3 Mechanical Systems and Existing Conditions Northfield Mental Healthcare Center Northfield, Ohio

EADQUARTERS. Technical Report One. Stephanie Kunkel Mechanical Option

HVAC System Consideration$ 05/14/2012 SAVING MONEY IN HVAC SYSTEMS

Strategies for Building Energy Efficiency

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

Single zone RTU, controlled by a programmable thermostat. Single zone RTU, generic description, with power exhauster

Dehumidifying with Dedicated Outdoor Air

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

MID MICHIGAN COMMUNITY COLLEGE HARRISON CAMPUS Harrison, Michigan 2015 MASTER PLAN

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

2009 IECC Commercial Mechanical Requirements

Senior Thesis Centre Community Hospital East Wing Addition - Proposal Keith Beidel Mechanical Option 12/05/02 1

MT. AIRY MIDDLE SCHOOL CARROLL COUNTY PUBLIC SCHOOLS

EarthWise System Seminar

NET ENERGY WATER LOOPS A clear path to net zero energy buildings

Evaluation. ems. Prepared By: Martha. a s Vineyard. Box P.O. Box June 2015

ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

FLORIDA A&M UNIVERSITY PERFORMANCE CONTRACT SCOPE OF WORK

Your Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons

General HVAC Recommendations

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

MEP CONDITION ASSESSMENT

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

Technical Assignment 3. Mechanical Systems Existing Conditions Evaluation

The School District of Philadelphia Administration Headquarters

Architectural Engineering Senior Thesis Mechanical System Redesign

COMcheck Software Version Review Mechanical Compliance Certificate

Description of All Alternatives Considered-

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

Technical Report Three

Shippensburg University

The Ed Roberts Campus

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

Christopher Kelly Technical Report Three

Submitted to. Texas A&M University at Commerce The Texas A&M University System. Submitted by. Guanghua Wei Craig Campbell David Claridge Dan Turner

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Air Conditioning Options Winnetka Public School District 36 Winnetka, Illinois November 4, 2016

Variable Refrigerant Flow (VRF) Systems

Technical Assignment 3

CONTROLLED CHILLED BEAM PUMP MODULE

Engineered for flexibility and performance

GARCIA GALUSKA DESOUSA Consulting Engineers

BRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application

ASHRAE JOURNAL ON REHEAT

HVAC DISTRIBUTION and DELIVERY SYSTEMS

Technical Investigation, Part Three Elizabeth C. Krauss Mechanical Option September 18, 2013

Daikin Blueprint: Delivering Hot Water with a Chiller

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

High Efficiency Heating and Cooling Systems for Community Colleges Kirk Mescher, PE, LEED AP Principal ICCCFO

APPA Institute for Facilities Management. Energy & Utilities Cooling Production (316) Purpose of Today s Presentation. Agenda

HVAC Controls Upgrades: Requirement Details ( )

Technical Assignment 3 11/15/04. Executive Summary

Job Name Control Systems Description Date

MECHANICAL INFRASTRUCTURE ASSESSMENT FOR VICTOR VALLEY COLLEGE

Cook - Wissahickon Elementary School

21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device

Terminal. Las Vegas, NV. Technical

1 - This title will copy onto other forms Date

Virginia Tech Standards for Building Automation System

Best Practices for Condensing Boilers

7. MECHANICAL SYSTEM DESIGN

MAXIMIZING HYDRONIC SYSTEM DESIGN PART III

HVAC Controls Upgrades: Requirement Details ( )

Paul McCown, PE, CEM, LEED AP, CxA Sr. Mechanical Engineer SSRCx, LLC Nashville, TN USA

APPLICATION GUIDE BEAMS

Engineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers.

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

ENGINEERING. Edition No. 13 October 2002

Appendices. Included in this section are

Richard Henry Lee Elementary School

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Appendix 13. Categories of Cooling and Heating systems

Challenges and Methods of Estimating a Conceptual HVAC Design

NEW FEATURES IN THE CARRIER HOURLY ANALYSIS PROGRAM v4.80

HONORABLE MENTION: COMMERCIAL BUILDINGS, EXISTING

BUILDING DESIGN STANDARDS. AIR CONDITIONING DIVISION 23 Heating, Ventilation and Air Conditioning

COMMERCIAL Washington Incentives

CHAPTER 4. HVAC DELIVERY SYSTEMS

Mechanical Technical Report 1. ASHRAE Standard 62.1 Ventilation Compliance Evaluation

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

Design Standard. Thermal Systems (Chilled Water and Hot Water Systems) Detailed specifications follow. CHW AND HHW SUPPLY TEMPERATURE RESET

Trials Tribulations & Rewards High T Heating Systems

Transcription:

ASHRAE Illinois Chapter 2015 Excellence in Engineering Awards PROJECT Chicago Vocational Career Academy Chicago, Illinois OWNER Chicago Public Schools PREPARED FOR American Society of Heating Refrigerating and Air Conditioning Engineers PREPARED BY Primera Engineers, Ltd. 100 South Wacker Drive, Suite 700 Chicago, Illinois 60606 312/606.0910

The Chicago Vocational Career Academy (commonly known as CVCA) is a public 4-year vocational high school, operated by the Chicago Public Schools (CPS), and located in the Avalon Park neighborhood on the South side of Chicago, Illinois. Originally built in 1938 with an approximate construction cost of $4 million, CVCA was opened in 1941 to help provide students with the technical skills to enter and succeed in the workforce. CVCA even contributed to the World War II effort by helping train airplane and aviation mechanics, instruct in national defense, and house trainees and recruits. Since then, thousands of students have graduated from the school s multiple training courses with the skills and knowledge to be better prepared for their careers in the trades. In early 2013, CPS set out to improve CVCA s infrastructure and renovate the facilities. The goal of this project was to create new and efficient career-focused classrooms to prepare students for jobs in a variety of high-growth industries, such as: automotive & engine, carpentry, health care assistance, cosmetology, culinary, Science, Technology, Engineering, and Mathematics (STEM), and horticulture. At roughly 800,000-square-feet, the school consists of three major wings: the Chappell Wing, the 87th Street Wing, and the Anthony Wing. The building is a stone and brick structure with the original 3-story structure along 87th street, and the remaining single and twostory structures to the North. Primera Engineers was engaged as part of the design team to provide mechanical, electrical and lighting design of this large-scale renovation project.

Mechanical System Description The mechanical ventilation system for the building consists of large air handling units built into rooms in the existing building along with ten rooftop air handling units, and some unit ventilators. Although the vast majority of the building has operable windows available for ventilation, the mechanical systems were designed to provide the code-required outside air. Previously the building only operated the air handling units as needed for heating. The existing steam plant consisted of three 400 boiler horse power (BHP) input boilers and one 200 BHP input boiler for a total of 1400 BHP for building heat and domestic hot water. This was replaced with a dual temperature water plant with variable-primary pumping. The new heating plant utilizes five 6,000 MBH input natural gas condensing type hot water boilers. The cooling plant utilizes two 460 ton centrifugal water cooled chillers. Two induced draft cooling towers were added to the boiler room roof. The dual temperature water plant utilizes three 75 horsepower primary pumps with variable frequency drives; two pumps operate in parallel with one pump as standby to provide 1700 GPM distributed to all heating and cooling devices to accommodate the building load. The dual temperature system uses 30% propylene glycol. The condenser water cooling tower system is a design consisting of two 460 ton, cross-flow cooling towers, each with one cell, a variable-frequency drive (VFD) controlled tower fan, and a 1,380 GPM base-mounted pump for each cooling tower piped together in parallel for redundancy. The entire mechanical system is monitored and controlled by a web-based, BACnet native building automation system (BAS) with live functional block programming and thermal graphic floor plans that reside on the CPS wide area network.

Energy Efficiency The heart of the project was to replace the outdated and inefficient mechanical heating system. Installing high efficiency boilers was an effective and efficient solution. The existing steam plant consisted of three 400 BHP input boilers and one 200 BHP input boiler for a total of 1400 BHP (47,000 MBH) for building heat and domestic hot water. The previous boiler system was estimated to be operating at below 70% efficiency. Due to the age of the piping and condensate pumps, the low pressure steam system had many small leaks which resulted in a loss of condensate, and with it a loss of chemicals. In addition, the small boiler was dedicated to provide heat for the pool and domestic hot water systems via heat exchangers, so the steam system needed to be operational year-round. The mechanical and plumbing systems were separated, and the pool and domestic water heaters were separated, to account for different usage and operation schedules. The domestic water heater is sized for 2,600 MBH, and the pool heater provides 750 MBH and both have efficiencies in compliance with IECC 2012. This provided a large amount of savings and allows for a minimal amount of combustion equipment to operate during the summer. Previous renovation projects replaced the windows, and part of this project repaired and added insulation to the roof as well as demolished a large portion of the building, approximately 30% of the area known as the Anthony Wing. These combined factors allowed for the boiler plant capacity to be reduced by more than 30%, approximately 13,500 MBH. The heating plant peak efficiency improved from approximately 70% to approximately 92%, as well as improving the controllability and turn-down ratio, which saved even more energy during off-peak periods. An energy model was developed to compare the existing steam plant to the new high efficiency hot water plant and resulted in a 125,000 THERMS/year reduction. This equates to a 22% natural gas energy savings per year when utilizing the same building composition, envelope and occupancy profiles. The model does not take into account the aforementioned reduction in building, any improvements to the air systems, or improvements to the building controls; which were replaced with modern controls to provide better temperature control over individual spaces to reduce overheating. In addition, the new dual temperature water system is also a variable primary system with significant improvement on the turn-down on each of the new boilers (5 to 1; which is a 25 to 1 turn-down for the plant). This allows for the heating system to be controlled to match the actual load during mild heating days. The variable-primary arrangements on both the ChW and HW plants saved considerable energy over conventional primary-secondary arrangements. On the air-side of the design there were many energy improvements as all of the supply fans were replaced for the major air handling units, providing improved fan and motor efficiencies.

The rooftop units were replaced with more energy efficient units as well, but possibly the largest energy savings for the ventilation design of the project was from a reduction in exhaust/relief air. Five of the air handling units were originally designed to relieve all air through the attic and out of the roof without the capability to return air back to the system. This type of once-through system is incredibly wasteful during morning warm-up and unoccupied times when the Large return fans were installed in the attic. systems were operating. Ductwork was added to bring the system up to code and allow the systems to return approximately 90,000 CFM of air that would otherwise have been exhausted when the system was operating. During occupied hours, these systems require approximately 32,000 CFM of OA, which means that the new systems have a 58,000 CFM reduction of exhausted air. During peak winter load conditions, this would save approximately 5,000,000 BTU/hr of energy. Indoor Air Quality As a part of this project, the filters and filter racks for all 10 existing AHUs were added or refurbished. Seven AHUs required new filter racks and filters, and three AHUs had existing filter racks that could be refurbished so that each unit has a MERV 8 rating. These AHUs provide 333,000 CFM of supply air total. The existing air systems that were historically controlled manually on and off as needed to provide heat to the building were updated with digital controls to provide heating and cooling as well as ventilation according to the building schedule. The fan systems now are scheduled to operate during all occupied hours which allows for filtered supply air to be circulated through the school more often. Operable windows are available for use during mild weather for free cooling, or opened when occupants desire allowing for individual room controllability. Innovation The design team used a number of cost-conscious efforts and technologies to stay within budget and also save the client money so that funds could be allocated elsewhere within the school. To start, the mechanical design included the installation of a dual temperature water system that was an economical choice and eliminated the need for the installation of additional pipes reducing that number by half. The dual temperature system distributes chilled water to 11 AHUs, and hot water distribution is to those same 11 AHUs, plus over 200 terminal units (reheat coils, UHs,

CUHs and finned tube radiators). All dual temperature piping was designed to create heating only loops throughout the building. This allows for these loops to be isolated via an automated isolation valve during chilled water mode and avoid condensing at the heating only units. A total of twelve heating only dual temperature loops were designed into the dual temperature piping systems. Upgrading the numerous 200 stand-alone UHs, CUHs and finned tube radiators to DDC was cost prohibitive, but the energy code requires temperature setback in these areas. The solution was found in the heating loop isolation valves. For a given area, a single DDC sensor, located in a representative location, was monitored for setback control. When any of the designated space sensors sensed a temperature below unoccupied heating setpoint (60 F), that zone s seasonal change-over valve would open to allow heating only units on that loop to control with local control until the single space sensor was satisfied. Operations & Maintenance Most of the mechanical equipment is located in the boiler room, or basement level of the building which allows for the equipment to be accessible without disturbing the school activities. All of the HVAC systems utilize modern and sophisticated controls to improve overall operation, maintenance and reliability. Sensors and alarms were programmed so that the maintenance staff is notified before systems need maintenance, or immediately when systems fail. Because of the compact design of the new condensing boiler plant in the existing boiler room there was ample space to allow for the existing boiler plant to be decommissioned while the new boilers were installed. Variable-primary pumping arrangements on hot water and chilled water loops limited the number of total central plant pumps to three, saving on floor space and limiting maintenance. The new boilers occupy approximately one third of The old steam boilers were demolished one at a time in order to make room for the new boilers, pumps and accessories. the floor space of the existing boiler room which left plenty of space for the new chillers and a separate area for the domestic water heating equipment. Access to the new equipment in the boiler room was greatly improved. Cost Effectiveness By using a dual temperature system (2-Pipe vs 4-pipe), the two-pipe distribution system saved close to half the material and installation costs over the 4-pipe system. This was estimated to have saved over $1,200,000. By using the largest condensing boilers available, only five boilers

were needed for the heating load. At the same time, the system provides redundancy, excellent turn-down, and energy efficiency. Utilizing the heating only loop seasonal changeover/isolation valves to satisfy the energy code setback requirement, in lieu of putting DDC controls on over 200 units, resulted in an estimated $120,000 first cost savings. New 460-ton water chiller. Environmental Impact The overall environmental impact of the school was improved by reusing the vast majority of the existing building. No CVCs or HCVCs were used - R-134a was used for large chillers and R-410a was used for RTU replacements. By using high efficiency combustion systems, emissions were limited. All of the energy savings resulted in a significant reduction in carbon footprint and CO2 emissions.

2100 E 87TH STREET CHICAGO, ILLINOIS 60617 WARNING: ASBESTOS - CONTAINING BUILDING MATERIALS ARE OR MAY BE PRESENT IN THIS BUILDING. AN ASBESTOS MANAGEMENT PLAN IS AVAILABLE IN THE SCHOOL FOR REVIEW UPON REQUEST. NO PERSON MAY DISTURB ASBESTOS - CONTAINING MATERIALS UNLESS THAT PERSON IS A LICENSED ASBESTOS WORKER OR CONDUCTS SUCH WORK IN ACCORDANCE WITH SPECIFICATIONS CONTAINED IN THE PROJECT DOCUMENTS AND IN COMPLIANCE WITH ILLINOIS DEPARTMENT OF HEALTH RULES AND REGULATIONS. MOTOR R F Architecture Engineering Planning Interiors R F MOTOR R F R F BID PACKAGE #1 L K H F A B J G E D C NORTH KEY PLAN Issuance : JANUARY 17, 2014 Mark Description Date ISSUE FOR BID 01/17/14 ISSUE FOR CONSTRUCTION 02/27/14 CENTRAL DUAL TEMPERATURE WATER PLANT SCALE: N.T.S. PBC Project Name: CVCA Renovation PBC Project No.: 05620 AOR Project No.: 22-13120-00 Title MECHANICAL WATER FLOW DIAGRAM Sheet M4.1 2014, DLR Group, Inc., an Illinois Corporation ALL RIGHTS RESERVED