VAC-U-DRY VACUUM DEHYDRATION SKIDS

Similar documents
VAC-U-DRY VACUUM DEHYDRATOR

VUD. Vac-U-Dry Vacuum Dehydrators. hyprofiltration.com/vud

Portable Purification zf04 Systems Models PVS 185, 600, 1200, 1800, 2700

VUD. Vac-U-Dry Vacuum Dehydrators. hyprofiltration.com/vud

Tel: Fax: Website:

ACORE Filtration Co.,Ltd provides engineering,

LIST Price - $2, Model Number: MFD-1-27-GX-X-B-14. *Quick Delivery of Units are Subject to Prior Sales

RMF SYSTEMS PURE POWER

Phoenix C4XE - Membrane Based Portable Lube and Hydraulic Oil Purifier Cart For use in Hazardous Duty Locations.

Vacuum Oil Purifier (VOP) (5 Pages. June 2017)

New Product Introductions 2011

PHoenix-M (Mini) PORTABLE LUBE AND HYDRAULICS OIL PURIFIER OWNER/OPERATIONS MANUAL

SPECIFICATIONS MODEL EHV X VACUUM OIL PURIFIER

OIL FILTRATION SYSTEMS, INC. 111 Parkway Drive, Boerne, Texas Phone: Web: oilfiltrationsystems.com.

Mobile Transformer Oil Purification Plant

Operations and Maintenance Manual

Phoenix C 1 GPM - Membrane Based Portable Lube and Hydraulic Oil Purifier Cart

Active Dry Air Venting for Water Contamination Control

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

重庆阳江机械制造有限公司. Electricity factory Transformer station Oil connection stations Transformer repair shop

CMM-R. CMM-R transformer oil regeneration plant. Oil regeneration CMM-6R

OIL TREATMENT ARRAS MAXEI

OIL TREATMENT ARRAS MAXEI

New levels of reliability for hydraulic systems

Desiccant Breathers: A Front Line Defense in the War on Contamination

ARV -3 & ARV -10 Active Reservoir Vent Installation and Operation Manual

ZL High-efficiency Vacuum Insulation Oil Purifier

MACH N-407 Heat Pump Air-Cooled Chiller

FluidAqua Mobil FAM Economy Series

5CONSIDERATIONS WHEN SELECTING A DESICCANT BREATHER FOR YOUR EQUIPMENT

OIL/WATER SEPARATORS. Compressed Air & Process Filtration

RNC Series SCFM Global Air Treatment

AIR SENTRY DESICCANT BREATHERS

CNC Series Refrigerated Air Dryer CFM

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series

FluidAqua Mobil FAM Economy Series

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

NON-CYCLING REFRIGERATED AIR DRYERS. RNC Series

CFH Series High Efficiency Filters

RNC Series SCFM Global Air Treatment

WORLD CLASS 2012 PRODUCT CATALOG. Filtration and Fluid Conditioning Products. Fluid Power

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

Dual Tower Heat Reactivated Desiccant Air Dryer

REFRIGERATED AIR DRYERS

MAC N-407 Air-Cooled Chiller

clean, dry compressed air

oil cleaner Electrostatic Product brochure

ZLA Series Double-stages Vacuum Transformer Oil Purifier Transformer Oil Purification

CPF PRODUCT DESCRIPTION

Active Reservoir Vent. Fluid Users

Sino-NSH Vacuum Double-stage Transformer

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Sino-NSH Turbine. Machine. Oil. Purifier. si si no-puri fi ca tion.com. htt p://tra ns formeroilfiltrat ion. w eeb ly.

Landfill & Digester Gas Dryers. Features and Benefits

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Laboratory Enclosed Rotary Screw Air Compressor System with Air Treatment Center Package

CPC PRODUCT DESCRIPTION

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

FluidAqua Mobil FAM 25/45/60/75/95 Series

The name to vacuum with...

CRN Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Refrigerated Compressed Air Dryers

Steele Extrusion Machinery

MATERIALS FILTERS PRESSURE VALUE TESTS CARRIED OUT ON FILTERING ELEMENTS

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL

FluidAqua Mobil FAM 5

CLEAN, DRY COMPRESSED AIR

Energy Impacts of Compressed Air

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Global Series Screw Air Compressors Life source of industries HP

Vacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager

Cold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)

WINDFERN ROAD HOUSTON, TEXAS D-500 Dry Polymer Make Up System

Single Tower Heat Reactivated Desiccant Air Dryer

Medical Vacuum Systems Product Selection Guide

Rust, corrosion and leakages threaten even the best network. Only Quality Air Solutions. in optimal shape. air distribution

NEW INTELLIGENT AIR TECHNOLOGY

L07 - L22. Oil Injected Rotary Screw Compressors. Intelligent Air Technology

Technical Specifications & Pricing

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

Adsorption Air Dryers

INSTALLATION AND SERVICE INSTRUCTIONS. Tuthill atlantic fluidics OSR-5, 10,15 & 20. Oil sealed liquid ring vacuum pump

D-1000 Dry Polymer Make Up System WINDFERN ROAD HOUSTON, TEXAS

CPVS PRODUCT DESCRIPTION

FX5 Series Explosion-Proof Electric Air Heaters

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

EG Series Screw Air Compressors Life source of industries kw

EHH SERIES DRAW THROUGH FAN COILS CFM

Pressure Swing Desiccant Dryers

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

TURBINE OIL FILTRATION AND DEHYDRATION UNIT - technical documentation - MODEL T1250

FORMULA. Rotary screw compressors. kw 5,5-7, , bar

PETECO VIETNAM EQUIPMENT JOIN STOCK COMPANY TYA VACUUM LUBRICATING/HYDRAULIC OIL PURIFIER

CHILLER. Operator s & Installation Manual

EG Series Screw Air Compressors Life source of industries HP

Flexible Solutions for Air Quality

Downstream Equipment. Intelligent Air Technology

Transcription:

VAC-U-DRY VAC-U-DRY VACUUM DEHYDRATION SKIDS Remove Free & Dissolved Water down to 20 PPM (0.002%) Remove Free & Dissolved gasses Standard Flow range 5~60 gpm,19~225 lpm (larger units available) Visually Monitor Fluid and Process through Clear Chamber Covers High Water Removal Efficiency Adjustable vacuum setting valve High Efficiency Particulate Filtration Low Watt Density Heaters Dimensional and Arrangement Design Flexibility Condensate Water Holding Tank with Automatic Drain Standard for 24 x 7 unattended operation Electrical Phase Reversal Standard Available PLC or VFD Control Fluxa Filtri S.p.A. V.le A.De Gasperi, 88/B - 20017 Mazzo di Rho (MI) Italy Tel. +39 02.93959.1 (15 linee) Fax +39 02.93959.400/440/470 - e-mail: info@fluxafiltri.com - www.fluxafiltri.com

VAC-U-DRY optimizes the balance between heat, vacuum and process design to rapidly remove dissolved water and gas. Keep your oil clean, dry and reliable! V10 Model Large air cooled condenser Air inlet breather. (particulate or desiccant) Dual stainless steel condensate tanks standard with clear covers for visual process inspection Several High output vacuum pump options available (lubricated vane dry seal shown) Clear vacuum chamber and condensate tank covers for visual monitoring of dehydration process. Auto water drain circuit allows for 24 x 7 continuous unattended operation Top loading particle filter assembly with coreless filter element and true p gauge Flexibility of design dimensions & process arrangement is an available option. We ll listen then customize a VAC-U-DRY for your specific application.

VAC-U-DRY User friendly... Clear vacuum chamber and condensate tank covers allow you to see the performance (condensation and collected water). Optional foam sensor and knockdown circuit. All condensate wetted parts are 304 stainless steel (standard) Low watt density fin tube heaters prevent coking with no direct contact between heating element & fluid. Ample plumbing makes Vac-U-Dry suitable for fluid viscosity to 460 cst. Ideal for high viscosity lubricating fluids Re-circulation line control valve Vac-U-Dry inlet Solid non-shedding wheels and forklift guides standard Standard Re-circulating line maximizes efficiency with cold start and allows adjustment system return flow rate. Model Length Inch (mm) Width Inch (mm) Height Inch (mm) Crated Weight Lbs (Kg) Dispersal Qty. V3 56 (1422) 32 (813) 48 (1219) 1300 (590) 2 V5 56 (1422) 32 (813) 60 (1524) 1900 (863) 2 V10 56 (1422) 32 (813) 60 (1524) 1900 (863) 3 V15 56 (1422) 32 (813) 60 (1524) 1990 (904) 3 V20 72 (1829) 36 (914) 60 (1524) 2100 (954) 4 V30 84 (2134) 40 (1016) 60 (1524) 2500 (1136) 4 (ext. length) V45 84 (2134) 48 (1219) 60 (1524) 2840 (1290) 8 (ext. length) V60 84 (2134) 60 (1524) 60 (1524) 3210 (900) 8 (ext. length) *Dimensions and weights are for standard models. Additional options may increase Vac-U-Dry size.

The Harmful Affects of Water in Oil Water is one of the most common and most damaging contaminants found in a lube or hydraulic system. Continuous or periodic high water levels can result in damage such as: Metal Etching (corrosion) Abrasive wear in hydraulic components Dielectric Strength Loss Fluid Breakdown Additive precipitation and oil oxidation Reduction in lubricating properties 75% of All Hydraulic Component failures are Caused by Fluid Contamination The effects of moisture in your oil systems can drastically reduce on stream plant availability. life and critical component life is greatly reduced by moisture levels above and within the saturation point. Many systems run constantly above this point due to inefficient dehydration technologies and high ingression. This develops acidity and loss of lubrication properties. Free water occurs when oil becomes saturated and Saturation Saturation cannot dissolve any additional water. This water makes the oil Fluid PPM % appear cloudy and can even be seen in puddle form at the bottom of a reservoir. Water which is absorbed into the oil is called dissolved water. At elevated temperatures, oil has the ability to hold more water in the dissolved state due to the expansion of the oil molecules. As the oil cools, it loses its capacity to hold water and free water will appear where Hydraulic Lubrication Transformer 300 400 50 0.03% 0.04% 0.005% previously not visible. Fluid type also determines saturation point in addition to temperature changes. New Moisture Level PPM (%) 1000 (0.1%) 500 (0.05%) 250 (0.025%) 100 (0.01%) 50 (0.005%) Current Moisture Level (PPM) 5000 2.3 1.6 3.3 1.9 4.8 2.3 7.8 2.9 11.2 3.5 2500 1.6 1.3 2.3 1.6 3.3 1.9 5.4 2.4 7.8 2.9 1000 1.4 1.2 2 1.5 3.3 1.9 4.8 2.3 500 Component Life 1.4 1.2 2.3 1.6 3.3 1.9 250 Extension by Removing Water* 1.5 1.3 2.3 1.6 100 1.4 1.2 *courtesy of Noria

VAC-U-DRY Increase Must Have Plant Reliability Contaminant VAC-U-DRY Centrifuges only remove free water that is well above the saturation point leaving harmful quantities of free and dissolved water in the oil. Desorbers and coalescing filters can achieve water levels of 150 ppm, but the process can be much slower or impossible with the presence of surfactants and additives. VAC-U-DRY rapidly removes water (below 20 ppm (0.0020% with desiccant breather) with efficiency to control water levels under normal ingression and regain control of high ingression conditions in hours instead of weeks or months. Water Type Particulate Gases The VAC-U-DRY Purification Process and Flow Diagram Air Capability Remove 100% free water 90% + dissolved water ISO Cleanliness Code 13/11/8 per ISO4406:1999 Remove 100% free gases 90% + dissolved gases Remove 100% free air 90% + dissolved air Contaminated oil is drawn into the VAC-U-DRY purifier by a high output vacuum pump. The oil passes through the low watt density heater where heated to optimum temperature for the dehydration process (150 o F, 66 o C). The oil enters the vacuum chamber passing through specially designed dispersal elements which create a thin film of oil that is exposed to the vacuum. The water is vaporized and then drawn into the condenser where it becomes liquid and drains into the condensate tank. V10 Model Air cooled condenser unit Vacuum chamber & dispersal elements Dry seal vacuum pump (liquid ring optional) Vacuum pump exhaust Auto-condensate drain circuit with dual tanks Air breather Condensate water drain Oil inlet Inlet control valve (optional) Re-circulating line Low watt density heaters (11 WPSI, 1.7 W/cm 2 ) Oil discharge pump Clean & dry oil outlet Top loading Solid particle filter βx[c] >1000 The dehydrated oil flows to the bottom of the vacuum chamber and is removed by the discharge pump. The oil is pumped through the high efficiency particulate filter assembly (βx [c] >1000) and returned to the system. The re-circulating line helps the VAC-U-DRY reach optimum temperature in cold start situations and can be used to throttle machine inlet and outlet flow.

Feature Description Condensate wet Better fluid compatibility with no price parts stainless adder (304 stainless standard) Flexible design Flexible dimensions, process setup & dimensions to suit your application (others won't) Programmable Precise temperature control, prevents thermostat overheating, unattended operation 27" max Hg vacuum yields rapid water Vacuum process and gas removal. Operational up to 20 meter (60 ft) negative head Clear covers on vacuum chamber Visual access and condensate tank allow visual inspection of oil condition and process Feature Description Achieve optimum temp faster. Reduce Re-circulation line flow rate for smaller systems. Maintain several systems with one VAC-U-DRY Condensate collection Heater system Auto condensate drain Electrical phase reversal standard All water removed does not go through vacuum pump extends vac pump life. Low watt density heaters prevent coking No direct heat element contact with oil Heat applied only when necessary Automatic condensate drain standard Maximizes uptime (24/7 operation) Electrical phase reversal automatically controlled in the control panel No guess work or switch to throw Operator Friendly Smart Relay - Smart relay enabled control panel performs controlled start-up & shut-down routines for ease of operation and keeps operators out of the control box. Includes machine drain sequence & automatic phase reversal (internally controlled, no guess work or switch to Programmable Thermostat - Programmable temperature controller for ease of operation and variable temp control with high limit safety setting. Heater Selector Switch (keyed) - Optional keyed selector switch for all units above 12KW. Suitable with mobile unit when AMP circuit does not allow for AMP draw with heat > 12KW (Multiple heaters can be deselected) Vacuum Pump Option Selection Code Description Maintenance Requirements C Dry seal (dry rotary claw) 20,000 hour maintenance oil change Long maintenance interval plus excellent portability D Dry seal (lubricated rotary vane) 500~750 hour maintenance oil / filter change Excellent portability L Liquid ring (external process Monitor water supply line filter, vacuum Ideal for hot, humid ambient water line ~ 3 gpm required) pump compound gauge (positive pressure) conditions, limited portability S Liquid ring (self-contained 1200 hour check vacuum pump in-line filter, Benefit of liquid ring vacuum pump water supply on-board) check vacuum pump water level often plus excellent portability C D L S

VAC-U-DRY High Performance Particulate Filter s βx [c] > 1000 Particulate Filter - A generously sized filter with a high efficiency filter element yields lower ISO Fluid Codes and enhances overall reliability. Achieve world class turbine lube reservoir cleanliness down to 14/12/9 with Vac-U-Dry high efficiency coreless filter elements. All elements include an integral bypass valve so the bypass valve is new with each element. Media Selection - Vac-U-Dry is available with a wide assortment of filter element media options to fit your specific application. Whether you re running low viscosity turbine lube oil requiring super cleanliness or conditioning high viscosity steel mill lubrication systems Hy-Pro will help you make right selection. Dynamic Filter Efficiency (DFE) Testing Revolutionary test methods assure that DFE rated elements perform true to rating even under demanding variable flow and vibration conditions. Today s industrial and mobile hydraulic circuits require elements that deliver specified cleanliness under ALL circumstances. Wire mesh supports the media to ensure against cyclical flow fatigue, temperature, and chemical resistance failures possible in filters with synthetic support mesh. Contact your distributor or Hy-Pro for more information and published articles on DFE testing and DFE rated filter elements. Glass Media Filtration Efficiency (Beta Ratio) vs Micron Size Beta Ratio 10000 1M 3M 1000 6M βx [c] = 1000 10M 16M 100 25M 10 2.5 4 5 6 7 10 12 16 22 25 Micron size µm [c] (per ISO16889) Estimated Water Removal Time - 5000 ppm (0.5%) to 150 ppm (0.015%) 100 90 80 Time (hours) 70 60 50 40 30 20 V3 V5 V10 V15 V20 V30 V45 10 0 0 4500 1190 9000 2380 13500 3570 18000 4760 22000 5,800 27000 7150 31500 8333 V60 36000 9500 40500 10,700 45000 11,900 Fluid volume (liters over gallons)

VAC-U-DRY PART NUMBER GUIDE V flow rate pump seal power dispersal element media seal heater condenser special options table 1 Flow rate gpm (lpm) 3 3 (11) table 6 V Seal material Viton (standard) 5 5 (19) E EPR 10 10 (38) 15 15 (56) 20 20 (75) 30 30 (113) 45 45 (169) 60 60 (225) Table 2 C D L Vacuum Pump type Dray seal (rotary claw) Dry seal (lubrificated rotary vane) Liquid ring (external water supply required) S Liquid ring (self-contained water supply on-board) *Consult literature for vacuum pump selection table 3 Power options 23 230 VAC, 3P, 60 Hz 38 380 VAC, 3P, 50 Hz 41 415 VAC, 3P, 50 Hz 46 460 VAC, 3P, 60 Hz 57 575 VAC, 3P, 60 Hz table 5 Discharge filter efficiency rating 1M ß2.5 [c] = 1000 (ß1 = 200) 3M ß5 [c] = 1000 (ß3 = 200) 6M ß7 [c] = 1000 (ß6 = 200) 10M ß12 [c] = 1000 (ß12 = 200) 16M ß17 [c] = 1000 (ß17 = 200) 25M 25W 40W 74W 149W 250W ß22 [c] = 1000 (ß25 = 200) 25µ nominal wire mesh 40µ nominal wire mesh 74µ nominal wire mesh 149µ nominal wire mesh 250µ nominal wire mesh table 4 D P Dispersal element Pleated dispersal (viscosity < 100 cst) Metallic packed (viscosity > 100 cst) table 7 Heater (KW) 12 12 KW 24* 24 KW 36* 36 KW 48* 48 KW table 8 A L B Heater (KW) air cooled liquid cooled air & liquid cooled * Possible high full Amp load ( consider special option J) table 9 Special option (add options to p/n in order they appear in table) 8 8 solid wheel upgrade A* Auto-condensate drain (supplied standard) B pre-filter Bag filter housing C CE mark (V5~V60) + International crating D dirty filter indicator alarm light E Carbon vacuum pump exhaust filter F vacuum chamber foaming sensor G 316 stainless condensate wet parts (304 std.) H manual reset hour meter (in addition to std. non-reset hour meter) J individual heater selector switches (24 KW and higher) for applications with limited amp circuit breakers K sight flow indicator (wheel type) L lifting eye kit M discarge line flow meter P water sensor + PLC control auto start/stop Q* + maintenance spares and repair kit R* Electrical phase reversal switch (supplied std.) T* Hose kit (suction & return hoses + wands) U Electrical cord 50 without plug (13 meter) V* Inlet control valve (for positive head inlet) W Water sensor and indicator Explosion proof Class 1, Div 2, Group C/D with air purge X (instruments quality air required). Consult factory for other explosion proof options Y Variable speed control (VFD drive) Z* On-site start up training (1 x 10 hour shift) * recommended options(auto-condensate drain & phase reversal standard) + Q option repair & sparer kit includes several items such as fuses, common relay, vac pump oil/exhaust filters, vac pump coupling, vac pump oil, panel bulb, vac chamber & condensate chamber covers, flow switch, heat thermocouple, replacement element set for vacuum chamber and particulate housing. Fluxa Filtri S.p.A. V.le A.De Gasperi, 88/B - 20017 Mazzo di Rho (MI) Italy Tel. +39 02.93959.1 (15 linee) Fax +39 02.93959.400/440/470 e-mail: info@fluxafiltri.com - www.fluxafiltri.com