Principle of Operation:

Similar documents
Self-regulating Roof Heat Cable

Toll Free:

Self-regulating Roof Heat and Gutter Trace Cable

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS INSTALLATION

NELSON HEAT TRACING SYSTEMS ALT-BC STANDARD POWER CONNECTION KIT

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS

Design Guide and Installation Details for Self-Regulating Heating Cable

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System

PLSRR Heat Trace Cable Data Sheet

XL-Trace System Application and Design Guide

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE EUROPE, MIDDLE EAST, AFRICA

Heat Tracing Sales Mt. Airy, Maryland Heating Cable. Cut to Length in Field. Description

NELSON HEAT TRACING SYSTEMS

Commercial and Residential Self-Regulating Heating Products

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM

NELSON HEAT TRACING SYSTEMS

Toll Free:

Thermal Devices, Inc. Mount Airy, Maryland USA Heating Cable. Cut to Length in Field

Roof and Gutter De-Icing

Toll Free:

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES

ROOF AND GUTTER DE-ICING ICESTOP SYSTEM

NELSON HEAT TRACING SYSTEMS

Heating cable solutions for temperature-related problems

Fire Sprinkler Freeze Protection Design / Install Guide

SELF-REGULATING PIPE TRACING HEATER CABLE

CATALOG. Toll Free:

SERGE BARIL GTKB GUT TRACE KIT BAG

H908 WinterGard Plug-in Power Connection Kit with End Seal

Drexan Energy Systems Inc.

INDUSTRIAL HEAT TRACE

DISTRIBUTOR GUIDE FOR SELLING QUALITY TO CONTRACTORS

F1202 TRACE HEATING. Road & Ramp

Freezer Frost Heave Prevention

Gardian W51. Approvals

INSTALLATIONGUIDE. HotSeam TM Overview ICE ROOF

SERGE BARIL HEAT TRACING SYSTEMS

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

HEATRACE. Young Chang Silicone Ltd, Co. SELF-REGULATING PIPE TRACING HEATER CABLE. Installation, Operation & Maintenance Manual

IceStop System INSTALLATION AND OPERATION MANUAL FOR ROOF AND GUTTER DE-ICING SYSTEMS

Chromalox PRECISION HEAT AND CONTROL. Cold Weather Electric Heat and Control Products

Consignes d installation

Radiant Edge LT TM Ice Melt System Installation and Operation Guide Version 1.4

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

IceStop System Installation and Operation Manual

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS

HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM

Technology for human beings that is, compatible with nature, creating permanent HEAT TRACING Dreams that can greatly improve the quality of life,

CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems

KE-Series Constant-Wattage Heating Cable

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance

Hot Water Temperature Maintenance. HWAT System. Product Selection and Design Guide

Tank Heating. Introduction. Self-Regulating Heating Cables

XL-Trace System Installation and Operation Manual

Design Guide Design Notes Design Examples Technical Data Sheets Expanded Capabilities Specifications Warranty

Installation & Maintenance

ROOF ICE MELT (RIM) SYSTEM

CATALOG. Toll Free:

SECTION ELECTRIC FLOOR HEATING AND SNOW MELTING EQUIPMENT

The IceFree Eave System

DESIGN GUIDELINES. THERMAL building SOLUTIONS

FRP HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL FRP.IOM.R1

Documentation. Parallel Heating Cable. Type: ELP

FRP HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL FRP.IOM.R1

Polymer solutions Heating mat EM2-CM

Installing Underfloor Heating Film. 1. Layout of electric underfloor heating systems

RX1200 ROOF AND GUTTER DE-ICING CONTROLLER INSTALLATION AND OPERATION MANUAL

Installation and Operation Manual

AKOCABLE Heating Cable Solutions Electrical Tracing

Department of General Services Real Estate Services Division Professional Services Branch Additional Detailed Instructions (ADI)

JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

PART GENERAL 1.01 SECTION INCLUDES

AKOCable Heating Cable Solutions Electrical Tracing

Flexible Heaters. of Silicone Rubber & Kapton

ROOF ICE MELT (RIM2) SYSTEM

MODEL SST 2 40 FREEZE PROTECTION THERMOSTAT MODEL SST FIXED SET POINT THERMOSTAT. Installation and Operation Manual

HEATING CABLE RATINGS APPROVALS* Drexan Energy Systems, Inc. Kelowna, BC, Canada, V4V 1S5

1SC-SSC Splice Connection Kit Installation Instructions

COMMERCIAL HEAT TRACING PRODUCTS AND SERVICES

Domestic Hot Water Application manual

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

FireSystems PROTECTOWIRE. Installing Protectowire Linear Heat Detector

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

Installation Instructions

RayClic Connection System

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Installation Instructions

HEATERS & SENSORS INC. - CATALOG

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Transcription:

SELF-REGULATING HEATERS Standard Overjacket Standard Metal Braid Stranded Copper Conductors Self Regulating Conductive Core Thermoplastic Elastomer Jacket Description: Nelson Type CLT selfregulating heater cable is a parallel circuit electric heater strip. An irradiation crosslinked conductive polymer core material is extruded over the multi-stranded, tin-plated, 18-guage copper bus wires. The conductive core material increases or decreases its heat output in response to temperature changes. A thermoplastic elastomer dielectric jacket is then extruded over the conductive core. A copper braid is installed over this jacket providing a continuous ground path. A UV stabilized thermoplastic elastomer overjacket is provided to cover the braid for wet applications and exposure to the sun. Principle of Operation: The parallel bus wires apply voltage along the entire length of the heater cable. The conductive core provides an infinite number of parallel conductive paths permitting the cable to be cut to any length in the field with no dead or cold zones developing. The heater cable derives its selfregulating characteristic from the inherent properties of the conductive core material. As the core material temperature increases, the number of conductive paths in the core material decreases, automatically decreasing the heat output. As the temperature decreases, the number of conductive paths increases, causing the heat output to increase. This occurs at every point along the length of the cable, adjusting the power output to the varying conditions along the pipe. The self-regulating effect allows the cable to be overlapped without creating hot spots or burnout. As the cable self-regulates it heat output, it provides for the efficient use of electric power, producing heat only when and where it is needed, and also limiting the maximum surface temperature. Application: Nelson's Type CLT self-regulating heater cable is ideal for use in maintaining fluid flow under low ambient conditions. Freeze protection and low watt density process temperature systems such as pipelines, fire protection, process water, dust suppression systems, hot water and structure anti-icing are typical applications for this product. For other than metal pipe heating, see appropriate application guide. The base product is supplied with a copper metal braid with a thermoplastic elastomer overjacket for wet applications, exposure to the sun, and where mechanical abuse is a problem. Cables are UL Listed and CSA Certified for use in non-hazardous locations and can be used on branch sprinkler systems. May 2015

PIPING FREEZE PROTECTION Cable Selection @ 0 F Minimum Ambient Temperature Application Design Conditions Maintain Temperature 40 F Type Fiberglass Wind Speed 20 MPH Safety Factor 10% Heater Attachment GT-6 Fiberglass Tape Metallic Pipe Applications* include Carbon Steel, Stainless Steel and Copper pipe. Non-Metallic Pipe Applications* include FRP, PVC, CPVC, HDPE, ABS and Polypropylene. The information in the tables below represents the wattage of cable necessary to meet the Design Conditions. CLT3 = 3, CLT5 = 5, CLT8 = 8. If a single pass of cable does not satisfy the heat loss requirement, then multiple passes are shown. Example: 5(2) (two passes of 5 watt product). Metallic Pipe Applications * 0.5 3 3 5 5 5 8 8 8 8(2) 8(2) 1.0 3 3 3 3 5 5 5 5 8 8 1.5 3 3 3 3 3 3 5 5 5 8 2.0 3 3 3 3 3 3 3 5 5 5 0.5 3 3 3 5 5 5 8 8 5(2) 8(2) 1.0 3 3 3 3 3 3 5 5 8 8 1.5 3 3 3 3 3 3 3 3 5 5 2.0 3 3 3 3 3 3 3 3 5 5 277 VAC @ 0.5 3 3 3 3 3 5 5 8 5(2) 8(2) 1.0 3 3 3 3 3 3 3 3 5 5 1.5 3 3 3 3 3 3 3 3 3 5 2.0 3 3 3 3 3 3 3 3 3 3 Non-Metallic Pipe Applications * 0.5 5 5 5 8 8 5(2) 8(2) 8(2) 1.0 3 3 5 5 5 8 8 8 8(2) 8(2) 1.5 3 3 3 5 5 5 5 8 8 8(2) 2.0 3 3 3 3 5 5 5 5 8 8 0.5 3 5 5 8 8 8 5(2) 8(2) 1.0 3 3 3 5 5 5 8 8 5(2) 8(2) 1.5 3 3 3 3 3 5 5 5 8 5(2) 2.0 3 3 3 3 3 3 3 5 8 8 277 VAC 0.5 3 3 3 5 8 8 5(2) 5(2) 8(2) 1.0 3 3 3 3 3 5 5 8 5(2) 5(2) 1.5 3 3 3 3 3 3 3 5 8 8 2.0 3 3 3 3 3 3 3 3 5 8 2 May 2015

PIPING FREEZE PROTECTION Cable Selection @ -20 F Minimum Ambient Temperature Application Design Conditions Maintain Temperature 40 F Type Fiberglass Wind Speed 20 MPH Safety Factor 10% Heater Attachment GT-6 Fiberglass Tape Metallic Pipe Applications* include Carbon Steel, Stainless Steel and Copper pipe. Non-Metallic Pipe Applications* include FRP, PVC, CPVC, HDPE, ABS and Polypropylene. The information in the tables below represents the wattage of cable necessary to meet the Design Conditions. CLT3 = 3, CLT5 = 5, CLT8 = 8. If a single pass of cable does not satisfy the heat loss requirement, then multiple passes are shown. Example: 5(2) (two passes of 5 watt product). Metallic Pipe Applications * 0.5 5 5 5 8 8 8 1.0 3 3 5 5 5 5 8 8 5(2) 8(2) 1.5 3 3 3 5 5 5 5 8 8 5(2) 2.0 3 3 3 3 3 5 5 5 8 8 0.5 3 5 5 5 8 8 1.0 3 3 3 3 5 5 5 8 8 5(2) 1.5 3 3 3 3 3 3 5 5 8 8 2.0 3 3 3 3 3 3 3 5 5 8 277 VAC 0.5 3 3 3 5 5 8 8 5(2) 8(2) 1.0 3 3 3 3 3 3 5 5 8 5(2) 1.5 3 3 3 3 3 3 3 5 5 8 2.0 3 3 3 3 3 3 5 5 Non-Metallic Pipe Applications * 0.5 8 8 8 5(2) 8(2) 8(2) 1.0 5 5 5 8 8 8 5(2) 8(2) 1.5 3 5 5 5 8 8 8 5(2) 8(2) 8(2) 2.0 3 3 5 5 5 5 8 8 5(2) 8(2) 0.5 5 5 8 5(2) 5(2) 8(2) 8(2) 1.0 3 5 5 5 8 8 8 5(2) 8(2) 1.5 3 3 3 5 5 5 8 8 5(2) 8(2) 2.0 3 3 3 3 5 5 5 8 8 5(2) 277 VAC 0.5 5 5 5 8 5(2) 5(2) 8(2) 8(2) 1.0 3 3 3 5 5 8 8 5(2) 8(2) 1.5 3 3 3 3 5 5 5 8 5(2) 8(2) 2.0 3 3 3 3 3 3 5 5 8 5(2) 3 May 2015

PIPING FREEZE PROTECTION Application Design Conditions Maintain Temperature 40 F Type Fiberglass Wind Speed 20 MPH Safety Factor 10% Heater Attachment GT-6 Fiberglass Tape Cable Selection @ -40 F Minimum Ambient Temperature Metallic Pipe Applications* include Carbon Steel, Stainless Steel and Copper pipe. Non-Metallic Pipe Applications* include FRP, PVC, CPVC, HDPE, ABS and Polypropylene. The information in the tables below represents the wattage of cable necessary to meet the Design Conditions. CLT3 = 3, CLT5 = 5, CLT8 = 8. If a single pass of cable does not satisfy the heat loss requirement, then multiple passes are shown. Example: 5(2) (two passes of 5 watt product). Metallic Pipe Applications * 0.5 5 8 8 8 5(2) 8(2) 8(2) 8(2) 1.0 5 5 5 5 8 8 8 5(2) 8(2) 8(2) 1.5 3 3 5 5 5 5 8 8 5(2) 8(2) 2.0 3 3 3 5 5 5 5 8 8 5(2) 0.5 5 5 5 8 8 5(2) 8(2) 8(2) 1.0 3 3 3 5 5 8 8 8 8(2) 8(2) 1.5 3 3 3 3 5 5 5 8 8 5(2) 2.0 3 3 3 3 3 5 5 5 8 8 277 VAC 0.5 3 5 5 8 8 5(2) 5(2) 8(2) 1.0 3 3 3 3 5 5 5 8 5(2) 8(2) 1.5 3 3 3 3 3 3 5 5 8 5(2) 2.0 3 3 3 3 3 5 5 8 Non-Metallic Pipe Applications * 0.5 8 8 5(2) 8(2) 8(2) 1.0 5 8 8 8 5(2) 8(2) 8(2) 8(2) 1.5 5 5 5 8 8 8 5(2) 8(2) 8(2) 2.0 5 5 5 5 8 8 8 5(2) 8(2) 8(2) 0.5 8 8 8 8(2) 8(2) 8(2) 1.0 5 5 5 8 8 5(2) 5(2) 8(2) 1.5 3 5 5 5 8 8 8 5(2) 8(2) 2.0 3 3 5 5 5 8 8 8 5(2) 8(2) 277 VAC 0.5 5 8 8 5(2) 8(2) 8(2) 1.0 3 3 5 8 8 5(2) 5(2) 8(2) 1.5 3 3 3 5 5 8 8 5(2) 8(2) 8(2) 2.0 3 3 3 3 5 5 5 8 5(2) 8(2) 4 May 2015

PIPING FREEZE PROTECTION Performance and Rating Data: Catalog No. CLT3 CLT5 CLT8 CLT23 CLT25 CLT28 Voltage (VAC) 120 120 120 240 240 240 Power Output @ 40 F (W/ft.) 3.2 5.4 8.6 3.2 5.4 8.6 Maximum Segment Length (ft.) 221 178 142 533 458 347 Minimum Installation Temp ( F) -35 F -35 F -35 F -35 F -35 F -35 F Current Load (amp/foot): At 0 F Start-up.072.100.143.036.050.071 At -20 F Start-up.080.111.158.040.056.079 At -40 F Start-up.088.122.174.044.061.087 Note: Amp/Foot values include 20% breaker derating per National Electrical Code. Circuit Breaker Selection: Maximum Length (feet) Vs Circuit Breaker Size Start-Up 120VAC 240VAC Watts/Ft. Temp. 15A 20A 30A 15A 20A 30A 40A 3 40 F 268 358 537 537 716 1074 1432 0 F 208 277 416 416 555 832 1110-20 F 187 249 374 374 499 748 998-40 F 170 226 340 340 453 679 906 5 40 F 192 256 384 384 511 767 1023 0 F 150 199 299 299 399 598 798-20 F 135 180 269 269 359 539 718-40 F 123 163 245 245 327 490 654 8 40 F 134 179 269 269 358 537 716 0 F 105 140 210 210 280 421 561-20 F 95 127 190 190 253 380 506-40 F 86 115 173 173 231 346 461 Notes: 1. Maximum segment length is the maximum continuous heater run with minimal voltage drop. For breaker loading, multiple heater segments can be installed in parallel providing no individual length is longer than the maximum published segment length. For voltages other than 240VAC, multiply the amps/foot value in the table above by the power adjustment value below, then divide full breaker amperage rating by the adjusted value to determine maximum total footage allowed. 2. Circuit breakers are sized per Article 427-4 of the 1999 National Electrical Code. 3. Article 427-22 of the National Electrical Code requires ground-fault equipment protection for each branch circuit supplying electric heating equipment. Electrical connections should be made by a licensed electrician. 4. Cable Selection Tables are designed for product selection over a wide range of piping materials. For specific applications utilizing heat transfer aids, such as AT-50 aluminum foil tape, consult your Nelson products representative. Voltage Adjustment: Use of Type CLT products at other than nominal voltages requires minor adjustments in power and maximum segment lengths. Catalog Numbers: Overjacketed Voltage 3 5 8 120VAC CLT3-JT CLT5-JT CLT8-JT 240VAC CLT23-JT CLT25-JT CLT28-JT Adjustment Multiplier 208VAC 277VAC Product Power Length Power Length CLT23.71 1.04 1.34.98 CLT25.80 1.01 1.22 1.02 CLT28.87 1.00 1.12 1.03 5 May 2015

PIPING FREEZE PROTECTION Pipe Size Standard Flange Additional Footage of Heater for Various Heat Sinks Blind Pipe Screwed or Flange Support Welded Flanged Valve Butterfly Valve Valve 0.50.3.5 1.0 1.0 1.0 1.0 0.75.3.5 1.5 1.0 1.5 1.0 1.00.3.5 1.5 1.0 2.0 1.0 1.50.3.5 1.5 1.5 2.5 1.5 2.00.3.5 2.0 2.0 2.5 2.0 3.00.5.75 2.0 2.5 3.0 2.5 4.00.5.75 2.5 3.0 4.0 3.0 6.00.75 1.0 2.5 3.5 5.0 3.5 8.00.75 1.0 2.5 4.0 7.0 4.0 End Seal - LT-ME Junction Box (not included in kit) In-line splice under insulation - LT-SS Heater cable loop Power Connection Kit - PLT-LPM Fiberglass Tape Pipe Clamps Heater Cable Tee splice under insulation - LT-ST Note: Heater cable power connections and end seals are included in Power Connection Kit (PLT-LPM). Additional heater cable end seals, splices, tees and thermostats are used as needed. Components and Accessories: Catalog No. Units Description PLT-LPM Ea. Power Connection Kit with Cable Seals LT-SS 5 Ea. Splice Kit Heat Shrink LT-ST 5 Ea. Tee Splice Kit Heat Shrink LT-ME 5 Ea. End Termination Cable Seals PC03 Ea. Pipe Clamp,.50-3.00 Pipe PC12 Ea. Pipe Clamp, 3.50-12.00 Pipe GT-6 Ea. Glass Fiber Tape, 60 Feet/Roll AT-50 Ea. Aluminum Foil Tape, 50 Yards/Roll WS-100 Ea. Warning Sign JB-552 Ea. Junction Box, 5 x 5 x 2, NEMA 4X TF4X40 Ea. Thermostat, 40 F Fixed Setpoint, NEMA 4X Enclosure TH4X325 Ea. Thermostat, 25-325 F, NEMA 4X Enclosure TA4X140 Ea. Ambient Thermostat, 15-140 F, NEMA 4X Enclosure 6 February 2009

ROOF AND GUTTER DEICER Total Cable Requirements: The total cable length for deicing is determined by including all elements of the roof system that need protection. Use the following tables to determine the total length of cable required. Item Feet of cable/ft. Item Comments Gutter 1' 1 Trace/6" gutter width Downspout 2' Unless downspout is on end of circuit, the cable is looped down and back Roof Valley 6' Per Valley Dormer 1' 1 ft. of cable/foot of dormer perimeter Cable Footage Required for Roof Overhangs (Feet of Cable per Foot of Roof) Eave Overhang Feet of Cable Shingle Roof Metal Roof Loop Height 12" 18" 1'-10" 2'-6" 24" 30" 2'-8" 3'-6" 36" 42" 3'-8" 4'-6" 48" 54" 4'-8" 5'-6" Performance and Rating Data: Catalog No. CLT5-JT CLT25-JT Voltage (VAC) 120 208 240 277 Power Output in Ice (W/ft.) 9.2 8.1 9.2 10.2 Maximum Segment Length (ft.) 141 370 377 381 Minimum Installation Temp ( F) -35 F -35 F -35 F -35 F Current Load (amp/foot): At 20 F Start-up.125.055.063.071 At 0 F Start-up.140.062.070.078 At -20 F Start-up.156.069.078.087 At -40 F Start-up.171.076.086.095 Note: Amp/Foot values include 20% breaker derating per National Electrical Code. Circuit Breaker Selection: Maximum Length (feet) Vs Circuit Breaker Size Start-Up CLT5-JT @ 120VAC CLT25-JT @ 240VAC Temp. 15A 20A 30A 15A 20A 30A 40A 20 F 120 160 240 240 320 480 640 0 F 107 142 214 214 286 429 571-20 F 96 128 192 194 258 387 516-40 F 88 117 175 174 232 348 464 Notes: 1. Maximum segment length is the maximum continuous heater run with minimal voltage drop. For breaker loading, multiple heater segments can be installed in parallel providing no individual length is longer than the maximum published segment length. For voltages other than 240VAC, divide full breaker amperage rating by amps/foot @ start-up temperature to determine maximum total footage allowed. 2. Circuit breakers are sized per Article 426-4 of the 1999 National Electrical Code. 3. Article 426-28 of the National Electrical Code requires ground-fault equipment protection for fixed outdoor electrical deicing equipment. Electrical connections should be made by a licensed electrician. 7 February 2009

ROOF AND GUTTER DEICER Cable Clip (SLT-C) Cable Connector (SLT-LPS) Conduit Junction Box (not included in kit) Aluminum Tape (optional) Nail or other support Drip Loop Hanger Wire End Seal (SLT-E) Heater Cable Gutter Detail Heater Cable Clamps Protective Tubing Downspout Downspout Hanger Detail (SLT-D) Heater Cable (shall not bulge or be visible) End Seal (should not be submerged nor be allowed to be at the bottom end of the downspout) End of Circuit Downspout Installation Components and Accessories: Catalog No. Units Description SLT-LPS Ea. Power Connection Kit with Cable Seals SLT-RC 25 Ea. Roof Clips SLT-C 25 Ea. Roof Clips (Universal) SLT-D 5 Ea. Downspout Hangers SLT-S 5 Ea. Splice Kit Heat Shrink SLT-E 5 Ea. End Termination Cable Seals Heat Shrink AT-50 Ea. Aluminum Foil Tape, 50 Yards/Roll TF4X40 Ea. Thermostat, 40 F Fixed Setpoint, NEMA 4X Enclosure TA4X140 Ea. Ambient Thermostat, 15-140 F, NEMA 4X Enclosure 8 February 2009

SELF-REGULATING HEATERS CSA Ordinary Locations APPROVALS UL Ordinary Locations C US Nelson Heat Tracing Systems products are supplied with a limited warranty. Complete Terms and Conditions may be found on Nelson's website at www.nelsonheaters.com. 9 February 2009

P.O. Box 726 Tulsa, OK 74101 918-627-5530 Fax: 918-641-7336 www.nelsonheaters.com 2015 Nelson Heat Tracing Systems May 2015