CHALLENGER 66 INDUSTRIAL Features: Available in two lengths Single or twin LEDs Surface mounting IP66 (dust tight & strong water jet proof) IK10 (20 joule) shock resistance Corrosion resistant High performance energy efficient Osram surfacemount-device (SMD) LEDs Available in (cool white) Average 50,000 hrs LED life L70 B10 Stainless steel quick release lens clips 20mm side knockouts for through wiring Options: Integral 3hr maintained emergency Integrated Manual Intelligent Control (MIC ) - see page 338 Integrated Remote Intelligent Control (RIC ) - see page 340 Dimming version available: - DALI (digital) Atex rated suitable for environments with a danger of explosion group II, category 3 (zone 2, 22) - on special request Accessories: Trunking mounting clips with body mount Trunking mounting pre-wired 0.75 metre plug and socket (up to 7 core) - white (standard) or red (emergency) Material: Body: polycarbonate Lens: polycarbonate Technical & Photometrics / / Challenger 66 Detail 150 180 150 120 120 90 90 50 100 60 150 60 200 250 30 0 30 C0 / C180 C90 / C270 cd / 1000 lm CHALLENGER 66 LED TWIN 2 x 24W, 8560lm Finish: Lens: cloud Colour: 05 Ash White 20mm conduit entry for through wiring Stainless Steel Quick Release Lens Clips Suspension mount Osram SMD LEDs 66
INDUSTRIAL Project: Sir Charles Groves Hall Carpark Client: Liber ty Living Product: Challenger 66 Options & Accessories MIC Sensor Trunking mounting clips with body mount RIC Sensor Challenger 66 Trunking mounting plug and socket (up to 7 core) White (standard) and red (emergency) Ordering Code Colour Temperature LED Lumens Delivered Lumens Luminous Efficacy 1x 17W LED 3316lm 2984lm 176lm/ W 1x 24W LED 4603lm 4280lm 1x 25W LED 4512lm 1x 36W LED 2x 17W LED 2x 24W LED Dimensions (mm) Length Width Depth Fixing Centre 30-101-470-405 178lm/ W 30-101-570-405 4196lm 168lm/ W 30-102-470-405 6357lm 5039lm 168lm/ W 30-102-570-405 6633lm 6168lm 181lm/ W 30--470-405 9205lm 8560lm 178lm/ W 30--570-405 2x 25W LED 9024lm 8392lm 168lm/ W 30-112-470-405 2x 36W LED 12715lm 11824lm 164lm/ W 30-112-570-405 Single - High Efficiency Single - High Output Twin High Efficiency Twin - High Output Options Add to Ordering Code Accessories Ordering Code Emergency (3 hour) E3- Trunking mounting clips with body mount (x2) A30-01-01-00 DALI (digital) dimming /DD Trunking mounting plug and socket (white) A30-03-01-01 Trunking mounting plug and socket (red) A30-03-01-16 MIC 1 /MIC1 MIC 2 /MIC2 MIC 3 /MIC3 RIC /RIC
MIC The Manual Intelligent Control (MIC ) system features a range of advanced sensor technology controls offering the ultimate in energy saving and carbon reduction. Significant energy savings can be achieved with a MIC system that dynamically manages luminaire power according to the instantaneous lighting requirement. It ensures that the right level of light appears at the right place only when required, thus preventing unnecessary energy consumption and reducing maintenance costs. The MIC system has been installed in over 3000 BT telephone exchanges with confirmed energy savings in excess of 70%. There are three types of Manual Intelligent Control: MIC 1, MIC 2 and MIC 3, available as a master (sensor incorporated) or a slave (controlled by master), to suit different requirements and budgets. MIC 1 A versatile and cost-effective ON energy saving control unit. Absence: luminaires are switched off. ON Occupancy detected: luminaires illuminate at full output unless there is sufficient daylight and the lux level setting overides it. Absence: after a preset time, luminaires switch off completely. MIC 2 Offers all the benefits of the MIC 1 but with a DIM ON DIM function. MIC 2 is an ideal control for reducing energy consumptions whilst still providing some level of illumination for extra safety. DIM Absence: luminaires are on at a courtesy preset dimmed level. Approximately 20% output and 1/3 total power. ON Occupancy detected: luminaires illuminate at full output. DIM Absence: after a preset time of absence, luminaires return to the courtesy preset dimmed level. MIC 3 MIC 3 is the most flexible energy saving manual control with an -ON-DIM- function, permitting optimal light management. ON DIM Absence: luminaires are switched off. Occupancy detected: luminaires illuminate at full output. Absence: after a preset time of absence, luminaires return to the courtesy preset dimmed level. After continued absence over a preset time, luminaires switch off completely. If required, the off function can be disabled to operate as a MIC 2.
MIC MIC Operating Functions and Features MIC 1 MIC 2 MIC 3 Operating function DIP Switch DIP Switch DIP Switch Lux level adjustment 0 2000 lux N/A 0 2000 lux Time adjustment to courtesy preset dimmed level N/A 5 30 mins 5 30 mins Time adjustment to switch off completely 5 30 mins N/A 10 30 mins Sensitivity (range) adjustment 2 10 metres 2 10 metres 1 6 metres Dimming level (ilite ballast/driver) N/A 10/25/50% 10/25/50% Detection angle 360 360 360 Sensor maximum load (inductive) 600W 600W 600W Detection Area MIC 1 & 2 MIC 3 0 0 Mounting Height (metres) Mounting Height (metres) 3.5 10 8 6 4 2 0 2 4 6 8 10 Detection area (metres) Setting 1 =2metres Setting 2 = 5 metres Setting 3 =10metres 8 10 8 6 4 2 0 2 4 6 8 10 Detection area (metres) Setting 1 = 1 metre S etting 2 = 3 metres Sett ing 3 = 6metres Typical Installation Options Option One The masters are all working independently for maximum energy efficiency to create a cascade effect. This is ideal for a retrofit installation. Option Two The master is working in conjunction with a slave to illuminate a specific zone. The master will control the slaves. Option Three The masters and the slaves are working in conjunction to illuminate a larger area. Option Four The masters are working together for increased efficiency and maximum sensitivity in a zoned area. Option Five The masters are working together for increased efficiency and maximum sensitivity in a larger area.
RIC The Remote Intelligent Control (RIC ) system is an advanced technology control system available on many of our luminaries. The luminaires have an integrated PIR available with a choice of detection angles, this integration negates additional wiring to remote sensors and allows for extremely versatile installations, especially where RIC luminaires are used in conjunction with slaved DALI luminaires. Operating parameters are highly customisable as each RIC luminaire (or luminaire cluster) is addressable using an infra-red programming handset. This allows the client to fine tune one or all of the systems varied features to their unique application features including: presence detection, lux level sensing, dynamic daylight compensation, zoning & scene setting. Capitalising upon the above core features this market leading system ensures the correct amount of light as and when required, in turn delivering significant energy savings. The RIC system is compatible with Plug & Connect rapid installation options. Occupation detected with limited daylight - luminaires maintain higher output, constant lux level and uniformity Occupation detected with no daylight - Luminaires maintain 100% output Presence detection and time delays manage corridor lighting requirements (for further details see presence detection overleaf) Emergency provisions integrated into RIC clusters Luminaire with integrated RIC sensor Luminaire output dimmed <10% Luminaire output dimmed 10-75% Luminaire output dimmed 100-75% No presence - luminaire off Occupation detected with high levels of light ingress - luminaires dim dynamically to maintain constant lux level and uniformity Prolonged absence in cluster areas - luminaires remain off Luminaire has integral 3 hour emergency Master/slave connection
RIC Presence Detection A passive infra-red (PIR) sensor is used to detect movement in a given space. Upon detection of presence the RIC system will turn the luminaire(s) on. Within the RIC system the luminaire(s) can be configured to dim or turn off following a predetermined period of absence. No occupancy detected therefore luminaires remain off or dimmed to pre-set output. Occupancy detected - luminaires illuminate corridor to a pre-set lux level (output adjusted in accordance with daylight ingress). Following prolonged absence, the luminaires can be either: Switched off Dimmed to a pre-set level Dimmed for a pre-set period before switching off Sensors Specification When specifying the RIC system, refer to the relevant luminaire datasheet and order as follows: 5m 2.8m 7m 2.8m 1. For master RIC luminaires suffix: /RIC-MD (medium distribution) or /RIC-WD (wide distribution) Medium distribution (MD) 2.8 metre ceiling Wide distribution (WD) 2.8 metre ceiling 2. For slave luminaires suffix: /DD (DALI) E.g. Airco recessed modular with RIC master and three slaves: 1 Quantity: 45-131-001-401/RIC 3 Quantity: 45-131-001-401/DD Product Images The remote control can easily program all RIC sensors. This feature can be saved and duplicated quickly and easily to the remaining sensors requiring the same lux levels. The compact infrared handset can be used for the basic programming of luminaires that incorporate RIC controls. The RIC sensor is suitable for controlling independant or multiple slave luminaires. The RIC sensor is integrated within the luminaire. This enables the luminaire to work in either a master or a slave (controlled by master).