Electromechanical Temperature Controls T631 Air witch Controller Air witch Controller with heavy-duty corrosion resistant steel case. uitable for lift motor rooms, farm storage areas etc. Line voltage switching: 3.7A () 5A(R) at 240VAC. PDT switches Temp Output Differential ndent -35 to 35 C 1 PDT 1.7 C fixed differential T631C1152-10 to 30 C 1 PDT 1.7 C fixed differential T631C1038 20 to 60 C 1 PDT 1.1 C fixed differential T631C1160 20 to 60 C 1 PDT 1.1 C fixed differential T631C1046 NZ 35 to 100 F 2 PDT 1.7 C fixed differential 2 tage. Adjust' interstage differential 0-4 C T631B1054 T675 Commercial Temperature Controller Ambient temperature compensated liquid filled copper elements with 1/2in diameter sensing bulbs. T675B compressor protection control, BOF, Manual Reset witch Rating (@ 240Vac) Capillary Length (m) ndent -15 to 35 C 0.5FLA 1.5 Fixed differential 0.6 C T675A1284-15 to 35 C 5.1FLA 1.5-15 to 35 C 5.1FLA 6.1 15 to 75 C 5.1FLA 1.5 15 to 75 C 5.1FLA 6.1 75 to 125 C 5.1FLA 1.5 75 to 125 C 5.1FLA 6.1 0 to 100 F 5.1FLA 3.0 cale in F et to break at 3 C T675A1169 T675A1920 T675A1466 T675A1474 T675A1243 T675A1250 T675B1002 T678 Two tage Temperature Controller Has 2 PDT switches that operate in sequence. Adjustable interstage differential and individual switch differential. witches rated 8.3FLA maximum total per controller. witch Rating (@ 240Vac) Capillary Length (m) ndent -15 to 35 C 8.3FLA 1.5 nterstage differential 1.7-5.6 C. witch differential 1.7 C -15 to 35 C 8.3FLA 6.1 nterstage differential 1.7-5.6 C. witch differential 1.7 C 15 to 75 C 8.3FLA 1.5 nterstage differential 2-6.7 C witch differential 2 C 75 to 125 C 8.3FLA 1.5 nterstage differential 2-6.7 C witch differential 2 C T678A1155 T678A1163 T678A1395 T678A1239 -L-06 EC Pacific Cat Honeywell nternational nc
Electromechanical Temperature Controls T6031 Refrigeration Controller Provide limit or temperature control in refrigerated areas where remote mounting of the sensing element is required. Liquid filled copper elements with 3/8" diameter sensing bulbs. witch Rating (@ 240Vac) Capillary Length (m) ndent -35 to 30 C 5.1FLA 2.4 2-9 C T6031A1086-35 to 30 C 5.1FLA 6.1 2-9 C T6031A1235 5 to 80 C 0.5FLA 1.7 Fixed differential 1.1 C T6031C1041 Remote ensor Temperature Controls T991A eries 90 Temperature Controller Proportional temperature controllers for modulating control of valves and actuators. Ambient temperature compensated, liquid filled copper elements with 1/2in diameter sensing bulbs. Capillary Length (m) Throttling ndent -15 to 35 C 1.5 1.7 to 17 C Output: 0-135 Ω T991A1095-15 to 35 C 6.1 1.7 to 17 C Output: 0-135 Ω T991A1103 15 to 75 C 1.5 1.7 to 17 C Output: 0-135 Ω T991A1210 15 to 75 C 6.1 1.7 to 17 C Output: 0-135 Ω T991A2119 75 to 125 C 1.5 1.7 to 17 C Output: 0-135 Ω T991A1152 T991E Burner Contoller Proportional temperature controllers for modulating control of boilers. Liquid filled copper elements with 1/2in diameter sensing bulbs. 0-135 Ω output. Has end switch to cycle burner on and off at low fire. Capillary Length (m) Throttling ndent 71 to 127 C 1.5 6 C Fixed differential 2 C T991E1018 -L-06 EC Pacific Cat Honeywell nternational nc
Remote ensor Temperature Controls T775 Electronic Temperature Control LCD display with individual output settings. ettings held in non-volatile memory. 24Vac, 120Vac or 240Vac Maximum distance from controller to sensor 300M, using 1sqmm cable. One 193987GA sensor included for each sensor input. Output relays rated 4.9FLA@240Vac. Adjustable switch differential 1-35 C. Modulating outputs throttling range 2 to 30 C. P+ Control on models with analog outputs. Note: electronic 135 ohm signal will not drive slidewire actuators. ensor nputs PDT Relay Outputs Analog Outputs ndent -29 to 116 C 1 2 T775A1019-29 to 116 C 1 4 T775A1035-29 to 116 C 2 4 T775B1026-29 to 116 C 1 1 0-135 Ω T775E1015-29 to 116 C 2 3 0-135 Ω T775F1022-29 to 116 C 2 3 0-18 Vdc T775F1089 4 to 104 C Wall mount temp sensor, indoor. 4 to 104 C Duct mount averaging sensor. C7130A1001 C7100A1015 Commercial Temperature Controls eries 90 Room Controller Room controller that provides modulating proportional control. 0 to 135 Ohm, 3-wire signal output. 24 Vac. Output ndent 15-30 C Proportional Heating Output White Order Q9065A1001 Base-plate separately T9065A2020 13-29 C Proportional Heating Output ilver Bronze Thermometer T921A1183 -L-06 EC Pacific Cat Honeywell nternational nc
Commercial Temperature Controls T8078C Room Temperature Controller Micro-electronic individual room controller. P+ control, 18-30 Vac input, modulating and 24Vac On/Off outputs with 3 modes of operation; 3 position modulating, thermal predictive modulating (TPM) for thermo-electric actuators and on/off. Can be used with remote sensors and remote setpoint adjustment. When used with a Q6360 subbase can switch 240Vac 3 speed fan. stops can be used to limit temperature adjustment. Output ndent 10-30 C P + Modulating TPM - On/off - 3 peed Fan Outputs for 240Vac 10-30 C Resistance etpoint & ensor ensor ensor Premier White ensor nput etpoint nput ubbase for switching Fan peeds Premier White Remote ensor & etpoint Controller Premier White Remote Wall-mount ensor Remote ensor No Enclosure - tops Bag of 20 T8078C1009 Q6360A1025 Q979C1036 Q979A1020 T8109C1002 F42006646-001 T7984 Modulating Temperature Controller Micro-electronic dial individual room controller. Modulating 2-10Vdc and 24Vac On/Off outputs. P+ Control. 24Vac Modulating Output (2-10Vdc) On/Off Output (24Vac) Auto Changeover ndent 1 Cool or 1 Heat - Yes for modulating T7984A1065 output 1 Cool or 1 Heat Heating or cooling No Day/Night Mode T7984B1063 1 Cool or 1 Heat Heat only Yes for modulating Day/Night Mode T7984C1061 output T9275A martronic70 Temperature Controller martronic is the ideal Controller for 2 or 4 pipe fan coil units or Heat exchanger. Used with a NTC20K sensor, it controls modulating and/or switched outputs. 24Vac. nput Output ndent -20 to 110 C 1 Analog (NTC20k) 1 Digital 1 Analog (2-10V/4-20mA) 1 Digital White and Grey P Control DN rail mountable T9275A1002 -L-06 EC Pacific Cat Honeywell nternational nc
Humidity Controls Room Humidity Controller Electro-mechanical nylon sensing elements. Adjustable setpoint. Mounting Humidity (RH) witch Rating @ 240Vac ndent Vertical 30-80% 4A(R) 1.5 A() Requires mounting plate - PDT Q9065A1001 H615A2036 Vertical or Horizontal 20-80% 6A(R) 2.2A() Differential 4-6% H600A1014 PDT Vertical 30-80% 0-135ohm modulating output Throttling range 12%. Requires mounting plate Q9065A1001 Mounting Plate for H615A2036 & H915A2022 H915A2022 Q9065A1001 H6120A Humidistat The H6120A single stage room humidistat is designed for monitoring relative humidity in air conditioning systems and for controlling air humidifiers and dehumidifiers for dehumidification control in indoor swimming pools. 230Vac, 50Hz Mounting Humidity (RH) witch Rating @ 240Vac ndent Wall 35 to 100% 5A(R) 0.2A() witching hysteresis 4% RH H6120A1000 H775 Remote ensor Humidity Control Remote sensor humidity control with LCD display. ndividual output settings. ettings held in non-volatile memory. 24Vac powered. Maximum distance from controller to sensor 300M, using 1sqmm cable. Use with C7600B, C sensors or other 4-20mA or 2-10VDC sensors. Application Humidity (RH) Contact Ratings @ 240Vac ndent Humidity Controller 5-95% 4.9A () 1 PDT witch H775A1006 Humidity Controller 5-95% 4.9A () 2 PDT witches H775A1022 Room Humidity ensor nput 16-28Vdc or 20-30Vac. Output 2-10Vdc. C7600B1000 olid state humidity sensor. Output 4-20mA. Positive slope. C7600C1008 H205 Electro-Mechanical Enthalpy Control Enthalpy control that senses total heat (humidity & temperature) of outside air. nylon humidity sensor. Liquid filled temperature sensing bulb. With mounting plate and adjustment knob. Mount Contact Ratings @ 240V ndent Duct Make on rise 2A Break on rise 250mA 12 to 26 C 10 to 80% RH PDT Contacts H205A1012 -L-06 EC Pacific Cat Honeywell nternational nc
Humidity Controls H705 olid tate Enthalpy Control Enthalpy control that senses total heat (humidity & temperature) of outside air. Consists of W7459A solid state economiser module + C7400 solid state enthalpy sensor on a mounting plate. For differential enthalpy control add second C7400. Mount Contact Ratings @ 24Vac ndent Duct 1.5A Run 3.5A nrush 7 to 35 C 20 to 90% RH PDT Contacts H705A1003 Limit Controls L4008/L6008 U Aquastats Aquastats used for control of hydronic heating systems. Complete with metal housing. Remote mount with 1.6M capillary. etpoint adjusted by screw on front of case in center of scale. Contacts rated 5.1FLA@240Vac - 3/8in diameter copper sensing bulb. witch High Limit ndent 100-240 F PT contacts break on rise L4008A1015 130-270 F PT contacts break on rise top factory set at 200 F 5-30 F adjustable differential L4008A1130 130-270 F PT contacts break on rise top factory set at 250 F Manual reset L4008E1040 40-120 C PDT witch with Ground and cover screw 3-18 C adjustable differential L6008A1184 L4188 European Aquastat mmersion-type thermostat for hot water boilers and hydronic heating, complete with plastic casing. Direct mount. lim, 5mm diameter sensing bulb. Contacts: 10A(R), 2.5A() @240Vac. - PT witch Mount Differential ndent 25-95 C Direct 4 C fixed Without thermowell L4188B2013B 40-100 C Direct 4 C fixed Without thermowell L4188B2005B -L-06 EC Pacific Cat Honeywell nternational nc
Limit Controls L6188 European Aquastat mmersion-type thermostat for hot water boilers and hydronic heating, complete with plastic casing. Direct mount or remote bulb with 1.5m capillary. lim, 5mm diameter sensing bulb. tandard models include thermowell - suitable for panel mounting. Tradeline model includes adaptors for existing Honeywell & competitor thermowells. Contacts: 10A(R), 2.5A()@240Vac - PDT witch Mount Differential ndent 25-95 C Direct 4-10 C adjustment L6188A2002 25-95 C Direct Manual reset nternal screw setting L6188C2016 NZ 25-95 C Direct 4-10 C adjustment Without thermowell L6188A2028 NZ 40-110 C Direct 4-10 C adjustment Tradeline model L6188A2044 40-110 C Direct 4-10 C adjusment L61882010 70-140 C Remote Manual reset nternal screw setting Without Thermowell L6188C2008 70-140 C Direct 4-10 C adjustment L6188A2036 70-140 C Remote 4-10 C adjustment pecial mounting bracket L6188B2018 100mm x 5mm Thermowell 45900409-003B L6189 European Aquastat mmersion-type thermostat for hot water boilers and hydronic heating, complete with plastic casing. Remote bulb with 1.5m capillary. lim, 5mm diameter sensing bulb. tandard models include thermowell - uitable for panel mounting. Tradeline model includes adaptors for existing Honeywell & competitor thermowells. Contacts: 10A(R), 2.5A() @240Vac - PDT witch Mount Differential ndent 40-110 C Remote Manual reset Panel mount L6189C2007 NZ nternal screw setting 40-100 C Remote 4-10 C adjustment Panel mount L6189A2043 NZ L6190 European Aquastat mmersion-type thermostat for hot water boilers and hydronic heating, complete with plastic casing. urface mount. Tradeline model includes adaptors for existing Honeywell & competitor thermowells. Contacts: 10A(R), 2.5A()@240VAC - PDT witch. Mount Differential ndent 25-95 C urface Manual reset nternal screw setting L6190C2004 NZ Without Thermowell 25-95 C urface 8 C Fixed L6190B2006 NZ -L-06 EC Pacific Cat Honeywell nternational nc
Limit Controls L6191 Twin Aquastat European Twin Aquastat with circulator and high limit controls. nternal screw setting on high limit. External knob setting on circulator. Complete with plastic casing. Fixed 4 C differential on high limit. Direct Mount. Contacts rated at 10A(R), 2.5A()@240VAC. Mount Differential ndent 25 to 95 C Direct Manual Reset on Limit Temperature 40 Limit to 110 C L6191B2005 40 to 110 C Direct 4-10 C on control L6191A2007 NZ 40 to 110 C Direct Manual Reset on L6191B2013 NZ Limit NZ L4064 Fan & Limit Control Fan and limit control for forced air heaters. Provide fan circulator control (fan controlled by duct air temperature) and high limit cut-out. Manual/Auto fan switch. High limit range 10-121 C. High limit differential 14 C. Fan on range 18-102 C. Fan off range 10-96 C. nsertion Length High Limit ndent 5 Off at 40 C Auto reset on high limit L4064B2640B 8 Off at 40 C Auto reset on high limit L4064B3051B 8 Off at 66 C On at 74 C Manual reset on high limit L4064N1066B 11.5 Off at 40 C Auto reset on high limit L4064B3044B 11.5 Off at 40 C Manual reset on high limit L4064N1058B 11.5 Off at 40 C High Limit 120 C Auto reset on high limit L4064B3069B NZ 11.5 Off at 66 C On at 74 C Manual reset on high limit L4064N1074B -L-06 EC Pacific Cat Honeywell nternational nc