Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

Similar documents
SITRANS T temperature transmitters A broad product family for every application. sitrans

SITRANS F M MAG 3100 P:

SITRANS F. SITRANS FUG1010 Clamp-on Gas Flowmeters. Answers for industry.

Process Gas Chromatograph

OMA-300 Process Analyzer

Process Gas Chromatograph

Process Instrumentation. Battery-powered, reliable and cost efficient. SITRANS F M MAG 8000 water meter for long-term accuracy. siemens.

SIFLOW FC070 Coriolis mass flow transmitter As easy to install as playing a CD. siflow

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Is your process protected?

Dräger Polytron 7000 Fixed gas detector

Temperature measurement with SITRANS T siemens.com/processinstrumentation

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

I Connected IndustriaI. ELSTER Q.Sonic plus. Ultrasonic Flow Meter for Natural Gas Custody Transfer Measurement

APPLIED. OMA-406R Rackmount Process Analyzer

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

Explore the future of flow measurement. SITRANS FC430 - the market s most compact Coriolis solution. Process Instrumentation. Answers for industry.

FM Approved Fire & Gas Detection System

Recent Improvements in Process GC Instrumentation

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

For Tough Environment. SINAMICS S120 liquid-cooled. SINAMICS drives. Answers for industry.

SITRANS F C MASSFLO Flow metering based on coriolis technology. sitrans f

SAFETY MANAGER SC Ensure safety, simplify operations and reduce lifecycle costs

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

continuous emissions monitoring Combustion & Environmental Monitoring

ClampOn DSP Pig Detector

Explore the future of flow measurement. SITRANS FC430 - the most compact NTEP approved Coriolis flow meter. Process Instrumentation

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Dew-Point Transmitters and Instruments

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

Tekmar-DOHRMANN The 3100 Sample Concentrator From ManualLib.com

Analyze IT. Process Gas Chromatograph. PGC2000 Series

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

USM GT400 Ultrasonic Flowmeter Proven Technology. Superior Performance.

Condumax II Hydrocarbon Dew-Point Analyzer

Datalogging as standard

Temperature Solutions Line Card

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Flexible Air-sampling Smoke Detection

SION Vacuum Circuit-Breakers

Dräger X-am 7000 Multi-Gas Detection

Gas Analyzers Modular gas analyzer, GMS800

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

Industrial Grade Gas Detection Detecting The Difference

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Dräger X-am 2500 Multi-Gas Detection

Dräger Polytron 8000 Stationary gas detector (EC)

Rosemount 1500XA Process Gas Chromatograph

Gas Measurement Products Catalog

custom cabinets and junction boxes

operations, Environmental & Instrumentation engineering solutions to the Commercial & Industrial segment in the Middle East. ARE

SUPREMATouch. Modular Fire & Gas Detection System

Autocalibration Systems for In Situ Oxygen Analyzers

intrinsically safe detector for hydrocarbon gases

CALIDUS tm the Modular micro Gas Chromatograph

Intelligent sensing for every temperature and condition

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

Altanium Temperature Controllers

EC 350 PTZ Gas Volume Correctors Enabling Precision Gas Measurement

Safe area; Zone 1 and Zone 2

Rosemount 1500XA Process Gas Chromatograph

Dräger Polytron 7000 Detection of toxic gases and oxygen

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger Polytron 8000 Stationary gas detector (EC)

CT EN rel. 10/09 Copyright Eliwell Controls s.r.l All rights reserved

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

Circulating Water Temperature Controller

Industrial Grade Gas Detection

How can the guess work be taken out of flow measurement?

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

The SharpEye 40/40I (IR3) Flame Detection

Gas Detection - GD -

II 1G EEx ia IIC T4 T a = -20ºC to +60ºC

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

A New Standard of Excellence

SUPREMATouch. Modular Fire & Gas Detection System

Improving Productivity, Quality and Security

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Arc Fault Protection System D1000

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

DISSOLVED GAS ANALYZER (DGA)

Dräger X-am 5000 Multi-Gas Detection

COBRIX3 multibev. Online Beverage Analyzer. ::: Unique Density & Concentration Meters

Process Gas Chromatograph

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

SPECIFICATIONS - DETAILED PROVISIONS Section Magnetic Flowmeters C O N T E N T S

Process Gas Chromatograph

D1000 Arc-fault Protection System

GasGard 100 Control System

Dependable Solutions for Gas Detection

Model D12-IR. Digital Gas Transmitter...

Condumax II Hydrocarbon Dew-Point Analyzer

/8 DIN Level Indicator

SECTION Fluorescent Dissolved Oxygen Measuring System

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

The Viva-ProE System

NO NO 2 NO x SO 2 CO CO 2 O 2

Dräger X-am 2500 Multi-Gas Detector

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

Transcription:

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV Answers for industry. 3

Many years of experience and state-of-the-art technology for highest performance Siemens has 30 years of experience with natural gas chromatographs and is the pioneer in applying microelectrical mechanical systems (MEMS) for online GCs. Chip-size valves and detectors combined with narrow-bore capillary columns offer unsurpassed performance and deliver a wide range of benefits. Unsurpassed accuracy Relative standard deviation for SITRANS CV: 0.007 % Linearity throughout the entire measuring range enables single-point calibration as confirmed by PTB, the German national metrology institute Detection limits are lower than 5 ppm even for neo-pentane Ambient temperature influence is negligible Exact measurements for every component mean precise correction factors for volume flow calculation No cross-sensitivity: narrow-bore capillary separation columns result in high separation performance Checksums verify correct parameter settings Independent from sample and ambient pressure due to unique live injection Cost-effective installation and operation Low power and gas consumption No shelter required it s rugged and compact. Just install SITRANS CV in the field at the sampling point Repair in minutes, just exchange analytical plug & play module, stable operation already 30 min. later Superior availability Only one calibration gas required due to high linearity, no linearization service needed During standby modus gas consumption only 6 ml/min Minimal maintenance time through: Maintenance-free valves Automatic self-diagnostics and optimization Easy-to-use yet powerful operation software Short cycle times of less than 3 minutes allow multistream analysis with one instrument Local Siemens service support Proven reliability 45 years of Siemens process GC experience are built into every component Maintenance-free valves based on chip-based MEMS technology: no moving parts for superior reliability Continuous self-checking and automatic optimization of parameter settings Rugged design: made for tough environments Proven software Embedded state-of-the-art electronic controller Electronic pressure controllers instead of solenoid valves Remote maintenance capabilities 2

Ease of use CV Control software makes the operations manual nearly unnecessary it s clear and easy to use SITRANS CV checks itself continuously. Six detectors monitor the analytic system at all gas outlets and inline constantly. Even the amount of injected sample is verified. Checksums verify correct parameter settings. During calibration SITRANS CV corrects automatically retention and even switching times. Critical operation levels are password-protected Troubleshooting and repair have never been easier and faster: You can replace the plug-and-play analytic module in just a few minutes using the Siemens exchange service, 30 min. later SITRANS CV is running stable again Local display and remote operation always provide operators with clear information and enable full control Maximum functionality Flexible communication via RS485 interface using the configurable MODBUS protocol or by Ethernet via TCP/IP. Other communication protocols and I/Os can be added with an optional expansion unit Calculation of upper and lower calorific values, standard density, and Wobbe Index; meets a wide range of standards and is certified by international testing authorities Country- or customer-specific setup, including all necessary information to meet individual requirements. Analytic module, controller and communications all functions are integrated Flexible installation with compact design and weight of only 15 kg, EEx d explosion protection, and IP65 / NEMA 4X splashwater protection. SITRANS CV can be mounted virtually anywhere on the pipe - line, offshore, or in other extreme environmental conditions SITRANS CV analyzes up to three sample streams and one calibration stream Reports including measurements and all calculated values are stored for 100 days, hourly averages for 1 year, daily averages for 2 years and monthly averages for more than 100 years Wide range of applications: Natural gas exploration Gas processing Gas storage Pipelines Gas turbines Gas distribution networks Custody transfer stations Power plants Landfills Steel plants Biogas LNG liquefaction and regasification 3

Set CV the standard for natural gas quality analysis Gas Supply Station Extension Unit Sample Probe Flow Computer Sample Conditio ning System SITRANS CV CV Control Set CV offers a standardized and complete system solution for SITRANS CV. The modular design means that options can be added to meet your requirements, from simple to extra security design. The set is suitable for one to three sample streams plus one calibration stream. The system is designed for use with stable, dry, and clean natural gas. Depending on the options specified, it can be used in a wide range of environments: Pressures up to 160 bar Ambient temperatures between 30 C to +55 C EEX 2G, T3 Trouble-free GC operation and data reliability Components from well-known producers with long industry experience Field-proven solutions Cost savings Up to three sample streams plus one calibration stream per system Protection of SITRANS CV, its components and measurement results Simple to maintain, easy to access 4

SITRANS CV at a glance Pioneer in applying microelectrical mechanical systems: Unsurpassed accuracy Single-point calibration saves calibration gases due to wide linearity Detection limit for neo-pentane: 5 ppm Analysis in less than 3 minutes Low operating costs Global service and support network Complies with relevant standards and certifications Low maintenance requirements Comprehensive automatic self-diagnosis and optimization Standby modus saves supplies Versatile communications Quick and easy repair based on plug & play analytical module Compact and rugged design enables field installation Power Environment Mounting Power 24 V typ.15 VA, max. 50 VA Ambient temperature 20 C +55 C operation 30 C +70 C storage Enclosure rating Area classification Dimensions Weight Mounting Gas connections IP65, NEMA 4X CSA Cl1, Div1 Gr. B, C, D T4 ATEX II 2G Eex d IIC T4 FM Cl1, Div1 Gr. B, C, D T4 FM Zone1 Gr. IIB+H2 T4 Diameter 30 cm (12 in) Height 23 cm (9 in) 15 kg (35 lb) Post, pipe or wall 1/8-in Swagelok Standards & Approvals ISO 6974-5, DIN EN ISO 6976, ISO 10723, ISO 13686, DVGW G260 and G262, GOST22667, AGA8, ANSI / GPA 2172-96, GPA 2145-03, PTB certificate, BRLM metrological certificate Communication, Interfaces Ethernet RS485 Digital outputs Digital inputs 10 Base T; TCP/IP MODBUS RTU / ASCII (Modicon or Danalyzer) 4 : 3 Streams, 1 cal 4 : Sample Flow, Sync, Revision, Cal Analytical System Detector 6 TCD sensors Cycle time < 180 sec Repeatability CV, density < 0.01 % Accuracy CV, density < 0.1 % Detection limit neo-pentane 5 ppm Calibration single point Measured Components Component Smallest Range in V % Largest Range in V % CH 4 90 100 55 100 N 2 0 0.1 0 25 CO 2 0 0.1 0 20 C 2 H 6 0 1 0 20 C 3 H 8 0 1 0 10 i-c 4 H 10 0 0.5 0 5 n-c 4 H 10 0 0.5 0 5 neo-c 5 H 12 0 0.1 0 1 i-c 5 H 12 0 0.15 0 1 n-c 5 H 12 0 0.15 0 1 C 6 + 0 0.1 0 3 C 6, C 7, C 8, C 9 Optional: individually separated for more accurate CV determination He Not measured, can be entered with at a fixed value H 2 S Not measured, max. 500 vpm Data storage Results, reports Hourly / daily / monthly average 100 days 1 year / 2 years / 166 years Calculated Values Upper and lower calorific value, density, Wobbe Index, specific gravity 1

Your Siemens partners worldwide Further information at: www.siemens.com/sitranscv Siemens AG Industry Sector Sensors and Communication Process Analytics Östliche Rheinbrückenstr. 50 76181 Karlsruhe Germany Siemens Energy & Automation Inc. 7101 Hollister Road Houston, TX 77040 USA Siemens Pte. Limited I IA SC PS/PA CoC 60 MacPherson Road Singapur 348615 Siemens Process Analytics Co. Ltd., Shanghai 12 Workshop, 175 XiMaoJing Rd. Export Processing Zone, SongJiang Shanghai, 201611 P.R. China www.ad.siemens.com.cn/en/ Siemens LLC II 2B. P.O. Box 2154, Dubai, U.A.E. Siemens AG Industry Sector Sensors and Communication 76181 KARLSRUHE GERMANY Subject to change without prior notice Order No.: E20001-A300-P720-X-7600 DISPO 27902 21/15716 MK.SC.PA.XXXX.52.8.05 WS 08085.0 Printed in Germany Siemens AG 2008 The information provided in this brochure contains merely general descriptions or characteristics of performance which in actual case of use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. 2