INFACT CORPORATION WATERWORKS PRODUCTS FLEX REDUCER SPECIFICATION S TOLL FREE:

Similar documents
ISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO

Full-line Product Overview

UL/FM Fire Protection Products. Reliable fire protection products for your commercial, industrial, or institutional property.

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

UL/FM Fire Protection Products Setting the Standard

UL/FM Fire Protection Products Setting the Standard

Solutions at every turn.

MARLOW PUMPS RECIRCULATION

EXPANSION JOINT PRODUCTS

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. In-Line Pumps IIL / IVP / IVP-CC

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

UL/FM Fire Protection Products. Reliable fire protection products for your commercial, industrial, or institutional property.

Dean Pump High Temperature Chemical Process Inline Pumps

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Kallista Bath Flip Drain

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

SAN ANTONIO WATER SYSTEM DSP Southeast Tank and Pump Station Project SAWS Job Nos (DSP) & Solicitation No.

Centrifugal Pumps acc. to EN / ISO 2858 with Shaft Sealing Type NCL

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

MCV - MCH - MCHZ Multistage pumps

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

Flow Control for Fire Protection

Installation Manual PS-225 & PS-275

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

SIHI multi Modular multistage pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

FAIRBANKS NIJHUIS SOLIDS HANDLING PUMPS.

Flow Control for Fire Protection

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. ASME/ANSI B73.1 Chemical Process Pump

Installation Manual PS-200 & PS-201

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

#2 ECLIPSE POST HYDRANT PARTS LIST. O-Ring for Top Screw (requires 2 per screw)

IMPORT PRICE LIST. version: IMP-JRPL EFFECTIVE: JANUARY 1, 2018 (SUPERSEDES ALL PREVIOUS PRICING) EFFECTIVE JANUARY 1, 2018

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Orange Township Fire Department Fire Prevention Bureau

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Facility Fire-Suppression Water-Service Piping

380 Series Multi-Stage Centrifugal Pumps

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

Worthington D-1100 vertical in-line pumps

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC

Grooved Piping System The only system that provides the option of rigidity or flexibility

Table of Contents INTMPE OVERVIEW ANSI B73.1 ANSI B73.1M API-610

SECTION STEAM CONDENSATE PUMPS

B. Utility-furnished products include water meters that will be furnished to the site, ready for installation.

Goulds Large Capacity, Single Stage, Double Suction Pump

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256)

Domestic Pump Condensate Transfer Equipment

UL/FM Fire Protection Products

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

Cable Drain & Cable Drain Trim Kit

IMPORT PRICE LIST. version: IMP-JRPL EFFECTIVE: APRIL 16, 2018 (SUPERSEDES ALL PREVIOUS PRICING) EFFECTIVE APRIL 16, 2018

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

TYPE VSM/VSMS VERTICAL SPACE MISER PUMPS

Big-Lock Tubing. Total Solutions for Air, Vacuum and Inert Gas Systems

FM 517 San Leon, TX Toll Free: Office: (281) Fax: (281)

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

TECHNICAL DATA. Wet 26a. February 22, 2009

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256)

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

FAN ENGINEERING. Sealing of Fan Housings

HIGH PRESSURE DOUBLE CASE PUMPS

Horizontal Split Case Pumps Type U

IMPORT PRICE LIST. version: CAN-IMP-JRPL EFFECTIVE: APRIL 23, 2018 (SUPERSEDES ALL PREVIOUS PRICING) EFFECTIVE APRIL 23, 2018

HOMA Pump, Ansonia Connecticut

Hydronic Expansion Joints (Part 2): It's All About the Guides

ETP Series - Self Priming Pumps

References are in agreement with UMRL dated April 2018 **************************************************************************

VALVES SECTION 15100

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. Open Impeller ASME (ANSI) B73.1 Pump for continuous use in Chemical Process Services

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

380 Series Multi-Stage Centrifugal Pumps

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

A. Codes and Standards that are Standard at the University:

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

PORTRAIT LITE VITREOUS CHINA REVERSE TRAP TOILET

TABLE OF CONTENTS DIVISION 21 - FIRE SUPPRESSION

Centrifugal Pumps acc. to DIN EN ISO 2858 with Shaft Sealing Type NCL

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

2. Welding Materials and Procedures shall conform to the ASME Code.

esfr dry pendent sprinkler Vk501 (k14.0)

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

B. Related Sections: The following Sections contain requirements that relate to this Section.

Performance at heart. Alfa Laval T35/TS35 gasketed plate heat exchanger

VACUUM VALVES AND HOSES

SECTION FIRE-SUPPRESSION PIPING

A. This Section includes the following fire-suppression piping inside the building:

STONE TROUGH CONSOLE SINK

Blockpumps. Vogel Series LSB. Lenntech. Tel Fax

Goulds 3600 Between-Bearing, Axially-Split, Multi-Stage Pumps. Goulds Pumps

Transcription:

INFACT CORPORATION WATERWORKS PRODUCTS REDUCER SPECIFICATION S TOLL FREE: 888-773-9130 email: info@infactcorp.com www.infactcorp.com

TIGHT SPACE RESTRAINT REDUCER-TO-VALVES AND FITTINGS U.S. PATENT NO. 6015170 MADE IN U.S.A. Saves space No pipe to saw Faster installation Fewer glands to tighten Epoxy coating standard Choose MJ or flange glands Heavy-duty machined glands MJ Glands spin and deflect for easy alignment No gimmicks uses standard gaskets and bolts CALL YOUR LOCAL WATERWORKS DISTRIBUTOR FOR PRICES. IN FACT www.infactcorp.com (888) 773-9130

ENGINEERING DATA / PRODUCT CHECKLIST ULTRA-COMPACT REDUCER SPACE-SAVING RESTRAINT (8 1/2-INCH DRAW-UP) REDUCER U. S. Patent No. 6015170 SIZES TYPICAL USES ADVANTAGES (Product) ADVANTAGES (Manufacturer) INFACT PRODUCTS ARE AVAILABLE FROM YOUR LOCAL WATERWORKS DISTRIBUTOR WATCH OPTIONS 8 x 6 MJ x MJ, 8-MJ x 6-Flange Restrains/reduces valves to tees and crosses Restrains/reduces 90 s and other fittings Heavy-duty casting, glands up to 1 1/2 times thicker Ultimate tight-space reducer with 8 1/2-inch draw-up length No pipe to saw or couplings to install No couplings or other parts mean fewer possibilities for leaks Glands interchangeable (on-site), 6-inch MJ or Flange glands MJ glands spin and deflect for easiest installation Split glands are machined Integral casting, no welds Uses standard bolts and gaskets Epoxy coating standard Less expensive than standard reducer assemblies Faster installation Products made in U. S. A. and Infact is an American-owned company SAME DAY shipping (orders received before noon) BIG inventory; backorders are extremely rare No extra charge to drop ship No minimum order 1) Each Flex Reducer requires the following: a) 1-each standard 6-inch bolt and gasket accessory pak b) 1-each standard 8-inch bolt and gasket accessory pak 2) The 6-inch flange gland uses flange bolts and an MJ gasket. Stainless steel kits

8 1/2 inch draw-up Ultra-compact Restraint with heavy-duty glands that spin and deflect making it easier and quicker to install Infact Ultra-compact Flex Adaptor Infact Ultra-compact Flex Reducer

Comparison of Waterworks Products that Restrain Valves, Fittings and Hydrants INFACT FOSTER ADAPTOR LUG PRODUCT INFACT T-2 & T-3 ANCHOR COUPLING INFACT ADAPTOR GRIP RINGS INFACT REDUCER Built-in full axial, circumferential restraint. Restraining forces are spread more evenly than in products using radial bolts or lugs. Bolt-through restraint Angular deflection for easy restraint of unaligned fittings Full axial rotation for easy alignment of bolt holes Two independent pivot points adjacent to fittings for better close quarters installation and easier connection to misaligned fittings X X X X X X X X X X X X X X X X X X X Requires ONE device to connect fittings (rather than two or more) Do not have to cut and install a piece of pipe in order for device to restrain fittings Uses standard bolts and gaskets and no radial bolts on pipe that operator may forget to or improperly tighten X X X X X X X X X X X X Field adaptable to being connected to any length pipe X X Field adaptable to restrain either MJ or flange joints using interchangeable glands X X X

TYPICAL REDUCER INSTALLATION CUT OUT Extra Space Extra Time Extra Parts Extra Money 8 1/2-inches installed U. S. Patent No. 6015170 Made in U. S. A.

ENGINEERING DATA / SPECIFICATIONS ULTRA-COMPACT REDUCER SPACE-SAVING RESTRAINT (8 1/2-INCH DRAW-UP) REDUCER U. S. Patent No. 6015170 REDUCER APPLICATIONS MJ Tees MJ Valves MJ Crosses MJ Hydrants MJ 90 s, bends Flange Tees Flange Valves Flange Hydrants Flange 90 s and bends Large Meters Backflow Devices REDUCER BENEFITS The Infact REDUCER is a patented product made in U. S. A. It meets the ductile iron and working pressure specifications of AWWA compact fittings, ANSI/AWWA C153/A21.53 American National Standard for Ductile Iron Compact Fittings 3-Inch Through 24-Inch (76mm Through 610mm) for Water Service. Other reducers require you to saw pipe or install couplings Save up to 2-feet of space with less chance for leaks Saves space No pipe to saw Faster installation Less chance for leaks Fewer glands to tighten Epoxy coating standard Mix or match glands MJ or flange Glands deflect and spin to easily align and install Heavy-duty split glands are up to 1.5 times thicker 9.05 12.00 8x6 Size 6.90 Conventional reducer installation REDUCER installation SAMPLE SPECIFICATION: Mechanical joint (MJ) and/or flange joint valves, fittings and hydrants shall be restrained using a positive restraint mechanism manufactured in the U. S. A. of ductile iron conforming to ASTM A536, Grade 65-45-12. Both MJ glands shall have the capability of rotating 360-degrees and deflecting the full deflection amount of a mechanical joint. The glands shall bolt to integrally cast barrel ribs without the use of lug bolts, and shall be interchangeable to allow either INFACT MJ glands or flange glands to be attached in the field. The MJ glands shall be attachable with standard bolts and gaskets conforming to ANSI/AWWA C111/A21.11. The flange glands shall be attachable with standard bolts and gaskets conforming to ANSI/AWWA C110/ A21.10 and flange drilling conforming to ANSI Class 125 B16.1. The device shall be supplied with a 7-mil NSF 61 approved fusion bonded epoxy conforming to AWWA C116/A21.16-09 as well as the coating, surface preparation and application requirements of ANSI/AWWA C550. The device shall be INFACT CORPORATION REDUCER or equal.

PRODUCT DESCRIPTION INSTALLED DRAW-UP DISTANCE TYPE OF JOINT RECOMMENDED APPLICATIONS MJ FLANGE VALVES FITTINGS HYDRANTS FOSTER ADAPTOR Bolt-thru MJ Adaptor Sizes 3-12: 1-inch --- Sizes 14-24: 2-inches --- Sizes 30-36: 3-inches T-2 Self-Restraining 2-way Tee 0 inches --- (Direct Restraint) T-3 Self-Restraining 3-way Tee 0 inches --- (Direct Restraint) ADAPTOR Ultra-Compact Coupling 8 1/2 inches REDUCER Ultra-Compact Reducer 8 1/2 inches