Index. Introduction. Pg 2. Powersaver - Single Element. Pg 3-5. Powersaver - Dual Element. Pg 6-11

Similar documents
Electronic 7 Installation Instructions

425 series Electro-mechanical Programmers

Clear investment. Pure energy. DOMESTIC TARIFFS EXPLAINED

DOMESTIC HEATING CONTROLS ARE EASY PART 2 - TIMERS & PROGRAMMERS

CentaurPlus ZW and HRT4-ZW

Where gas is not an option,

Kills bills. How Vaillant technologies reduce home heating bills

Home owner user pack for the Nibe 200P

RT021 User and Installation Instructions

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

Electrisaver User and Installation Instructions

C-Stat 17-ZW User Instructions

Oxfordshire Community Groups & Volunteers. Top Tips. Compiled by Dale Hoyland, Strategic Development Manager, NEF

Understanding your supply area and meter types. Help Beat Cancer Fixed Price Energy January 2019 v2

NATURAL VENTILATION CONTROL SYSTEMS

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

Recommendations texts (9.82) to be used on Energy Report in Scotland 18 July 2008

On initial power up the thermostat will guide you through set up procedure for the following:

ESi CONTROLS BROCHURE LANDSCAPE V5.indd 1 14/08/ :31

Controls for domestic central heating and hot water guidance for specifiers and installers

103E5. Installation & User Instructions. Electronic timeswitch for controlling hot water and heating. including Factory Replacement Units (FRU)

ImmerSUN-Frequently Asked Questions

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

ADVANCE ECB ELECTRIC COMBINATION BOILER

Frequently Asked Questions

Operating Manual. Series Touchscreen Programmable Demand Control Thermostat. UtilityPRO TM

heating system Quantum at home The heater that adapts to its environment dimplex.co.uk/quantumathome

RF Programmable Room Thermostat User Instructions

Semi flush-mount room thermostats

The world s most advanced direct electric water cylinder

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ

Energy Ambassadors Guide

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

MAKING MODERN LIVING POSSIBLE. CP715Si. Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water. User Guide.

Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs.

RVL470. Heating Controller. Use. Functions. Series B

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

THERMAL RADIATORS STORAGE HEATERS PANEL HEATERS TOWEL RAILS CENTRAL HEATING BOILERS.

ES3247B. 3 Channel Programmer. User and Installation Instructions

Saving Energy. We promote equality of opportunity in every aspect of our business in line with our objectives.

Amptec. Electric flow boiler

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

Multi family Housing and thermostats. Utility costs represent the single largest controllable cost in an apartment community

5245 / Thermotouch 4.3dC. Dual Control Thermostat. Installation & User Guide

danfoss Heating Solutions 5

PROGRAMMABLE ENERGY SAVING TIMER. ASAP Timers, LLC Multi-Family Timer Model A-1. User Manual

PRECISION CONTROL FROM MYSON PLUS

Wired Solutions Wired Heating Control Products

Room Sensor [RBT-3C] Installation Instructions

Marco Beverage Systems Ltd.

Room thermostat with Auto Timer, Option External Input

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

CS027 User Instructions

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

EUROSTER 2510 USER MANUAL 1 EUROSTER 2510

RVP310. Heating Controller. Building Technologies HVAC Products

Instruction FH-CWP Thermostat

Room thermostat with Auto Timer, Option External Input

Sun Ray Electric Radiators Stylish, Efficient, Low Energy

ENERGY EFFICIENT ELECTRIC RADIATORS YOU CAN RELY ON. The professional heating solution

Operating Guide: for the Warmup tempo Digital Programmable Thermostat Part of the Element Series Introduction

RVL480. Heating Controller

Lighten. the Load! MASTERS. SUPPLY! Timeguard s range of Fused Spur Timeswitches. Savings! LIGHTING. Countdown. On Demand! ALSO INSIDE THIS ISSUE

RADIO DRIVER. * _Rev.1* User guide. Wireless programmer. RADIO DRIVER zone RADIO DRIVER zones RADIO DRIVER zones

Combined electric boiler and domestic hot water store

Digital Room Thermostat

Room-temperature (economy/night) unit TR 212 E

RVL479. Heating Controller. for use with a partner unit

INTELI PRODUCT CATALOGUE. Issue 1,

Operating Instructions

AVANT DGS. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

CentaurStat 7 User Operating Instructions Central Heating Programmable Room ThermoStat

Energy Efficiency Advice.

multimatic Operating instructions Operating instructions For the operator AT, BE (de), CH (de), DE VRC 700f/4 Publisher/manufacturer Vaillant GmbH

Heating Controls Technical

Q1. The table gives information about some methods of conserving energy in a house.

Operation Guide CT80 ENGLISH

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

Room thermostat with Auto Timer, Option External Input

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

4iE Smart WiFi Thermostat Operating Guide

multimatic Operating instructions AT, BE (de), CH (de), DE VRC 700f/4

Room thermostats with LCD for wall mounting

MAKING MODERN LIVING POSSIBLE INT INT EFIT 550. User Guide and Installation Manual. Danfoss Heating

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

PULSACOIL A CLASS USER GUIDE. TEL:

STAY WARM STAY HEALTHY

Lifestyle Electric Thermal Radiator

Lifestyle Electric Thermal Radiator

Electronic timeswitch

Heating Control Danfoss Link & Connect Thermostats

Heating controller with optimisation functions

Cork County Energy Agency

Economy Standard Comfort. Heat loss (W/K) Heat loss (kwh/24h) (3)

Operating Instructions Model : HC HC-N

SCS311 / SCS317 Installation Instructions

102E7. Installation & User Instructions. 7-day electronic mini-programmer for controlling hot water and heating

Find out more visit speedfitufh.co.uk or call Take control with JG Aura Wireless TRV & Heating Controls. speedfitufh.co.

Transcription:

family

Index Introduction Powersaver - Single Element Powersaver - Dual Element Pg 2 Pg 3-5 Pg 6-11

The Powersaver range provides the time control facility needed to help households lower their electric hot water costs by minimising energy consumption. Sangamo Powersaver products are a set of simple to use, multi application controllers which offer a wide choice of programming functionality & flexibility. All of the products are designed to control the timing operations of applications such as water heating to ensure expensive energy is not wasted. Heating and hot water heating account for 43% of a home s energy usage (mapawatt.com) - the Powersaver range can reduce energy and fuel costs for these domestic applications. The Powersaver range has the ability to switch a resistive load of 16amps and varies from the simple Powersaver Boost switch which has a boost period of 30 minutes, 1 and 2 hours; to the fully programmable 7 day Powersaver 24/7 switch. There is also a new dual immersion controller (PS Dual) and boost timer (PSB Maxi) available. Due to its functionality the Powersaver is the control of choice for many Local Authorities, private builders and electrical contractors. In fact, many local authorities use the Powersaver to achieve their housing objectives set within the Social Housing Quality Standards and the Code for Sustainable Homes. The Powersaver range is aesthetically pleasing and with single immersion element applications, the Powersaver product can fit into a single gang pattress box. 2

Application Ideas: Typical Applications Immersion heater- Single Element Fan heaters Storage heaters Panel heaters Towel Rails 3

& Boost timer with 30mins, 1 hour and 2 hour boost periods Ideal for applications that need short term operating times Indicator light shows boost time period Fits directly into a single gang patress box Boost timer with 1 hour, 3 hour and 5 hour boost periods Specifically designed to be used with appliances that need to be left on over a period of time but that can be easily forgotten to be switched Switches appliance off automatically after boost period Indicator light shows boost period Fits directly into a single gang patress box Product Range PSB Boost - User-selectable, half, one or two hour boost, 16A, 230V, 50/60Hz PSB Maxi Maxi - User-selectable, one, three or five hour boost, 16A, 230V, 50/60Hz Contact Rating Supply Fixing Resolution of Programs Power Consumption Live Parts Protection Dirt and Moisture Protection Shock Protection Case Material Type of Action Temperature Rating 16A Resistive 240V a.c. 230V 50/60 Hz a.c. Single Patress - Surface and Flush Mounting N/A 10VA Maximum This unit is totally protected by the enclosure IP00 Class 1 (this unit must be connected to earth) Polycarbonate Type 1B T35 Operation Temperature 0 o C to 35 o C Memory Reserve Display Program Settings Boost Settings Control Pollution Category none none none Technical characteristics PSB - User selectable - 1/2, 1 or 2 hours PSB Maxi - User selectable - 1, 3 or 5 hours Normal 4

&, Powersaver Daily 24 hour electronic timer with up to 3 program operations per day Powersaver Weekly 5 day / 2day electronic timer with extra program operations for weekend Powersaver 24/7 7 day electronic timer with up to 3 operations per day All give the ability to program electrical appliances in order to improve their energy efficiency as well as enchancing their functionality to increase the comfort of the end user Product Range PSD Daily - 24 hour, three programmes daily, half, one or two hour boost, memory reserve, 16A, 230V, 50/60Hz PSW Weekly - Five day / Two day programmer, three programmes week days, additional three programmes Saturday/Sunday, half, one or two hour boost, memory reserve, 16A, 230V, 50/60Hz PS24/7 24/7-7 day, three programmes daily, half, one or two hour boost, memory reserve, 16A, 230V, 50/60Hz Technical characteristics Contact Rating Supply Fixing Resolution of Programs Power Consumption Live Parts Protection Dirt and Moisture Protection Shock Protection Case Material Type of Action Temperature Rating 16A Resistive 240V a.c. 230V 50/60 Hz a.c. Single Patress - Surface and Flush Mounting 10 Minutes 10VA Maximum This unit is totally protected by the enclosure IP00 Class 1 (this unit must be connected to earth) Polycarbonate Type 1B T35 Operation Temperature 0 o C to 35 o C Memory Reserve Display 4 Hours - when on power for previous 12 hours LCD Program Settings PSD - 3 Programmes repeating PSW - 3 Programmes weekdays & 3 Programmes Satuarday/Sunday PS24/7-3 Independent programmes per day. Boost Settings User selectable - 1/2, 1 or 2 hours Control Pollution Category Normal 5

Application Ideas: Typical Applications Immersion heater - Single or Dual Element 6

The Powersaver Dual can be used with low-rate electricity tariffs. The PS Dual has a set of pre-set programs to chose from- covering all of the low rate electricity tariffs, including Economy 7, Economy 10 & Eco 20:20 times: electromechanical programming selection with digital functionality. The PS Dual helps to lower energy costs and ensures installation is fast and painless. The pre-set program times cannot be changed which is good news for the installer as there will be no unnecessary maintenance call outs. For the convenience of the end user, there is a programmable boost function for your heating & hot water, up to a maximum of 2 hours. This is to make sure expensive, on-peak electricity is not wasted. The PS Dual is designed as a direct upgrade of Sangamo Quartz 7 and Horstmann E7Q. View the PS Dual demonstration video at www.sangamo.co.uk 7

Dual immersion controller with pre-set programs for Economy 7, Economy 10 and Eco 20:20 tariffs. Tamper proof program settings - factory pre-set Automatic GMT/BST changeover Rotary switch for pre-set program choice Direct upgrade to Horstmann E7Q and Sangamo Q7 controllers Wiring Diagram Product Range PS DUAL Dual Immersion, 24 hr, half, one or two hour boost, 2hr max programable boost, pre-set programs for low rate tariffs. Rating Live Parts Technical characteristics 13A, 230V, 50Hz, suitable for immersion heaters up to 3Kw Enclosed Power consumption 1.2W Dirt Protection Shock Protection Class 1 Contacts Temperature Battery Reserve Clock Accuracy Dimensions Program Cycle Summer/Winter Time change IP30 Micro-Disconnection 0 to + 35 o C Approx 2 years, Non Rechargeable Lithium +/- 5mins per year @ 23 o C H x W x D (mm) 114x169x60 24hour Automatic Off Peak Program Installer Selectable - Up to 10 presets available covering low rate electricity tarrifs Boost Facility Boost Program User selectable - 1/2, 1 or 2 hours User selectable - Up to 2 hours Single Immersion Heater Dual Immersion Heater Two Immersion Heater 8

Coming Soon! The PS Dual Flexi is an immersion controller that can be used with low-rate electricity tariffs. The PS Dual Flexi has a set of pre-set programs to chose fromcovering all of the low rate electricity tariffs, including Economy 7, Economy 10 & Eco 20:20 times. The PS Dual Flexi allows pre-set program operating times to be minimised or cancelled, which means settings can be tailored to suit different installation requirements. Yet vitally, the PS Dual Flexi still ensures that all programs only operate within off peak tariff hours. The benefits of this are that expensive electricity is not being used or wasted unnecessarily, and that the user can have flexibility in their hot water control. For further convenience there is a boost button and a boost program function, each a maximum 2 hours, to make sure on-peak electricity usage is limited. This will further reduce energy consumption and electricity bills. The PS Dual Flexi has been designed to make installation fast and painless. The PS Dual is a direct upgrade of Sangamo Quartz 7 and Horstmann E7Q - no rewiring is required. To set programs and operating times, the installer simply refers to the tariff table and turns the rotary switch to the program of choice. 9

Dual immersion controller with flexible pre-set program times for Economy 7, Economy 10 and Eco 20:20 tariffs. Flexibility in pre-set operating times but ensures programs only operate within off-peak tariff hours Ability to minimise or cancel operating times Automatic GMT/BST changeover Rotary switch for pre-set program choice Direct upgrade to Horstmann E7Q and Sangamo Q7 controllers Wiring Diagram PS Dual Flexi: Dual immersion, 24 hr, half, one or two hour boost, 2hr max programmable boost, pre-set programs with flexible operating times for low rate tariffs. Product Range PS DUAL Flexi Dual Immersion, 24 hr, half, one or two hour boost, Rating Live Parts Technical characteristics 13A, 230V, 50Hz, suitable for immersion heaters up to 3Kw Enclosed Power consumption 1.2W Dirt Protection Shock Protection Class 1 Contacts Temperature Battery Reserve Clock Accuracy Dimensions Program Cycle Summer/Winter Time change IP30 Micro-Disconnection 0 to + 35 o C Approx 2 years, Non Rechargeable Lithium +/- 5mins per year @ 23 o C H x W x D (mm) 114x169x60 24hour Automatic Off Peak Program Installer Selectable - Up to 10 presets available covering low rate electricity tarrifs Boost Facility User selectable - 1/2, 1 or 2 hours Single Immersion Heater Dual Immersion Heater Two Immersion Heater 10

Economy 10 Tariff- explained. We are constantly reminded of the need to reduce energy consumption, and the message seems to be getting across as we see a growing demand from consumers for more ways to save in this area. With rising fuel costs and consumers feeling the effects of the recent recession, cutting energy consumption is one of today s top priorities. The ordinary consumer may well be more concerned with their electricity bill than with cutting CO² emissions, but by adopting the Economy 10 tariff, they will be helping with both. The Economy 10 tariff has been around for six years now, and is provided by many UK suppliers. It is designed for use with electrical boilers which drive radiators to air/ground heat pumps, as well as high thermal mass heating such as storage heaters, underfloor heating and water heating. The tariff gives households 10 hours of discounted off-peak electricity spread throughout the day. Users of the tariff have the benefit of seven hours of discounted electricity in the evening and overnight, with an extra three hours in the afternoon. Matching the storage periods to the times when heat is required, means less heat needs to be stored during the day, when there may be little or no demand. This reduces energy consumption and subsequently energy costs. The afternoon and evening periods provide a top up to heating systems at off peak prices. If a consumer is on Economy 7 and they find they are running out of hot water, or if their storage heaters are cooling off by the evening, then Economy 10 could well be a viable solution. In addition to the energy used by heating and hot water, the electricity used at the off peak times by domestic appliances is also charged at the lower rate. Times allotted to Economy 10 vary across suppliers, and are switched automatically. It s common for the switching times to be locked to either GMT or BST when the meter is installed. Some metering systems use a radio teleswitch controlled by the supplier to vary switching times, so Economy 10 requires a special multi-tariff meter, which enables them to measure the consumption of electricity between the set Economy 10 hours as specified by the supplier. Very often a time switch is used to set boilers, night storage heaters, and other appliances to automatically switch on during the cheaper period, allowing them to heat as much water as possible with low cost electricity. The UK Government has set a target of cutting CO² emissions by 34% of 1990 levels by the year 2020 and many measures are being introduced to help achieve this, including the phasing out of inefficient light bulbs and encouraging consumers to reduce stand-by losses on appliances. Using the Economy 10 tariff can also help by controlling energy use and energy costs. 11

Sangamo Limited Industrial Estate Port Glasgow Renfrewshire PA14 5XG Tel: 01475 745131 Fax: 01475 744567 Web: www.sangamo.co.uk Email: enquiries@sangamo.co.uk