EFFECT OF 2D AND 3D COIL ON THE DYNAMIC MOLD TEMPERATURE CONTROL BY INDUCTION HEATING

Similar documents
Induction heating with the ring effect for injection molding plates

BỘ CHỈNH LƯU KÉP 3 PHA THREE - PHASE DUAL CONTROLLED RECTIFIER

Nguyễn Phùng Quang và cs Tạp chí KHOA HỌC & CÔNG NGHỆ 63(1): 50-55

PEGASOS. Bộ điều khiển số cho đầu máy xe lửa với hệ thống truyền động bằng Diesel - Điện và Diesel - Thủy lực

GIẢI THUẬT DI TRUYỀN VÀ ỨNG DỤNG TRONG HỖ TRỢ LẬP LỊCH ĐIỀU HÀNH CÔNG TÁC BỆNH VIỆN

User manual Citrus Juicer

INSTRUCTION MANUAL HƯỚNG DẪN SỬ DỤNG

INSTRUCTION MANUAL HƯỚNG DẪN SỬ DỤNG

USER MANUAL HƯỚNG DẪN SỬ DỤNG

MỘT SỐ VẤN ĐỀ VỀ ĐỒNG BỘ DỮ LIỆU KHÔNG GIAN

Operating and Installation Instructions. Induction hobs MH-02IS MH-03IS

[EN] Use and installation manual. [VIE] Hướng dẫn sử dụng và bảo dưỡng 8. induction cooktop. Bếp cảm ứng từ Model: GH 027IS.

Modeling and Simulation of Rapid Heating and Cooling of Mold by FEA

HƯỚNG DẪN SỬ DỤNG USER MANUAL. Model : MDR 302

bếp hỗn hợp điện từ MODEL: GH 027IH mixed induction / hi-light cooktop [EN] Use and installation manual [VIE] Hướng dẫn sử dụng và bảo dưỡng 8

NGHIÊN CỨU SỬ DỤNG GREENSTONE TRONG VIỆC XÂY DỰNG THƯ VIỆN SỐ

GIS-BASED MANAGEMENT OF URBAN TREE AND GREEN SPACES IN VIETNAM CITIES

LINH DAM NEW TOWN - SOLUTION FOR THE HIGH-DENSITY DEVELOPMENT OF NEW SETTLEMENTS IN THE SOUTH-WEST OF HANOI

HẬU QUẢ CỦA VIỆC HỦY BỎ HỢP ĐỒNG THEO BỘ LUẬT DÂN SỰ NĂM TS. Võ Sỹ Mạnh Khoa Luật, Đại học Ngoại thương Hà Nội

Le Van Banh - Hoang Bac Quoc

Bếp cảm ứng từ Model: TOM 02I-G5

HƯỚNG TỚI TƯƠNG LAI THE FUTURE IS UP

User manual Chopper. Models: CHB Always keep manual for your safety

RTNT290E50VZX RTNT340E50VZGW RTNT340E50VZX

KỸ THUẬT SỐ (Digital Electronics)

THIẾT BỊ & GIẢI PHÁP PRODUCTS & SOLUTIONS

MÁY SẤY QUẦN ÁO TUMBLE DRYER. HƯỚNG DẪN SỬ DỤNG INSTRUCTION MANUAL Model : MTD-B0603E

ELECTRIC OVEN Model. TO-24E

Assembly instructions Hướng dẫn lắp đặt

ĐỘNG TÍNH TỪ ID: PARTICIPLES (ĐỘNG TÍNH TỪ/ PHÂN ĐỘNG TỪ)

A Study on the 2-D Temperature Distribution of the Strip due to Induction Heater

RCNT340E50VZX RCNT340E50VZX RCNT340I50VZX RCNT375E50VZDX RCNT375E50VZX RCNT375I50VZX RCNT415E50VZDX RCNT415E50VZGW EN TV

AH-A18LEW AU-A18LEW AH-A24LEW AU-A24LEW HƯỚNG DẪN SỬ DỤNG MÁY ĐIỀU HÒA KHÔNG KHÍ LOẠI HAI KHỐI RỜI SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL

Operating Instructions Induction Heating Cooktop For domestic use Model No. KY-C227D KY-A227D

EFFECT OF TEMPERATURE ON PHYSIOLOGICAL ACTIVITIES OF TOMATO Cv. SAVIOR DURING POSTHARVEST RIPENING

HONEYWELL VIỆT NAM HONEYWELL VIETNAM

SELECTION OF SALT TOLERANCE GENOTYPES FROM DOUBLED HAPLOIDS IN RICE. Dang Minh Tam, Nguyen Thi Lang

EHC7240BA. Ceramic glass hob. Hướng dẫn sử dụng. Bếp điện

DVD Player and Spa Installation Guide

Natural Convection Heat Transfer Augmentation from Heat Sinks using Perforated Fins: A Review

WASHING MACHINE MÁY GIẶT

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

EMS3288X. Instruction Manual. EN Microwave Oven TH VI Lò vi sóng. Hướng dẫn sử dụng

Purdue e-pubs. Purdue University

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

Heat transfer and heating rate of food stuffs in commercial shop ovens

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

TAM KY S MASTERPLAN TOWARDS GREEN GROWTH

Optimization of Thin Film Heater/Sensor Design for Miniature Devices Using Finite Element Analysis

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

Thick-Film Heater achieves Superior Performance in Thermal Response, Uniformity and Efficiency.

Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a)

K.F. Fong *, C.K. Lee, T.T. Chow

A Space Where Cultivating Relationships SERIES LUXURY

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

Analysis of Triangle Heating Technique using High Frequency Induction Heating in Forming Process of Steel Plate

Minco SmartHeat SLT Self-Limiting Thin-Film Heater Technology

APPLICATION OF MINI HEAT PIPES FOR THERMAL MANAGEMENT OF OPTO-ELECTRONIC INSTRUMENTS

LAMINATION AND CHARACTERIZATION OF A POLYETHYLENETEREPHTHALATE FLEXIBLE MICRO HEAT PIPE

A Novel Approach for the Thermal Management. of PC Power Supply

power-saving period in summer, in which one of the indoor units was forced to change from a cooling mode to a fan mode, was introduced, and the effect

Laboratory study of the effects of green roof systems on noise reduction at street levels for diffracted sound

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

A Statistical Analysis of a Liquid Desiccant Dehumidifier/Regenerator in an Air Conditioning System

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Optimized Finned Heat Sinks for Natural Convection Cooling of Outdoor Electronics

PCUA DAIKIN Applied Products

COOLING OF BIKER S HELMET USING PELTIER MODULE

Thermal Performance of a Loop Thermosyphon

EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Thermal Simulation of a Heat Pipe Tempered Injection-Mould Tool

Development and Application of Micro Channel Heat Exchanger for Heat Pump

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

International Journal of Engineering Research & Science (IJOER) ISSN: [ ] [Vol-2, Issue-11, November- 2016]

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

I] WHAT IS INFRARED? SW C FMW C MW C LW- upto 650 C

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Control Method Of Circulating Refrigerant Amount For Heat Pump System

TRAINING FOR HOMESTAY OPERATION. Module 8: Housekeeping service. esrt programme

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR

How Computer Simulation Helps to Design Induction Heating Systems

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES

Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Modification of Passivation Unit in Galvanizing Line

Compression of Fins pipe and simple Heat pipe Using CFD

Kinh giri: Thu tnrong cac don vi trong Truong

Global Journal of Engineering Science and Research Management

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

Proceedings Design, Fabrication and Optimization of a Silicon MEMS Natural Gas Sensor

Best Light for Life. Van My Khanh Co.

Transcription:

Tạp chí Khoa học và Công nghệ 52 (4) (2014) 409-417 EFFECT OF 2D AND 3D COIL ON THE DYNAMIC MOLD TEMPERATURE CONTROL BY INDUCTION HEATING Phạm Sơn Minh University of Technical Education of Ho Chi Minh City, Vo Van Ngan Str. 1, Thu Duc District, Ho Chi Minh City Email: minhps@hcmute.edu.vn Received: 11 July 2013; Accepted for publication 10 March 2014 ABSTRACT Electromagnetic induction heating has many advantages such as fast heating, low energy consumption and reduced environmental pollution. Using induction heating for rapid tool heating is more economical and efficient than any of the current tool heating techniques. In this research, using both experiment and simulation, the 2D and 3D design of induction coil were applied to verify the heating capacity of mold plate. With the 2D coil, after 2 s for heating, the temperature of mold plate can increase from 40 o C to 108 o C. However, the low temperature area appears at the center of the mold plate. On the contrary, when the 3D design was used, the max temperature reached to 89 o C at the end of heating period, and the low temperature area was removed. Keywords: injection molding, dynamic mold temperature control, induction heating, coil design. 1. INTRODUCTION Injection molding technology has been widely used in almost all fields of plastic product manufacture. The mold surface temperature has great influence for plastic injection molding. With high mold surface temperature, the surface quality of part will be better, but the cooling time will increase and accordingly the cycle time will rise as well. Maintaining high mold temperature during the filling process and lowering the mold temperature to below deflection temperature during the post-filling process without greatly increasing cycle time and energy consumption are not easy. In recently researches, before the filling of the melt into the cavity, the mold surface has a heating step for raising the temperature up to the glass transition temperature of the plastic. This process was called Rapid Heat Cycle Molding RHCM. In injection molding field, the RHCM has some requirements as fast heating rate, low energy consumption, and the cooling step of the injection molding can operate easily For the heating process in RHCM, there are two main types of heating systems in use, surface heating and volume heating. With the surface heating method, several techniques have been researched. An insulation layer is coated onto the mold surface then a heating layer is applied to the insulation layer as the cavity surface. The heating layer can be quickly heated with

Phạm Sơn Minh a pair of electrodes and the insulation layer is used to enhance heating efficiency and decrease consumption [1, 2]. On the other hand, for raising the mold surface temperature in the filling process, a coating on the cavity surface with TiN and Teflon has reduced the heat transfer from the melt to the mold material, which increased the temperature on the cavity surface to 25 C [3, 4]. In another research project, on the heating surface, an electromagnetic induction coil with different configuration was used to heat the cavity surface to reduce the weld line, shrinkage and other defects of the part surface [5, 6]. Furthermore, an infrared heating system was also applied for heating the mold surface. This system can heat the surface of one or two mold halves using a suitable design [7, 8]. For the newest application of surface heating, the hot air flowed into the cavity and heat convection from the hot air can directly heat the surface of the cavity [9]. The advantage of surface heating is the high rate in heating, so, the cycle time can be reduced. However, the user must have a special mold design when the mold is complex, and more equipment is needed to calculate the parameters for a high quality product. For volume heating, the most inexpensive way to achieve high mold temperature is to use hot water at a temperature as high as 90 C or 100 C for both heating and cooling. If the mold temperature needs to be higher than 100 C, either a high pressure water supply system or a hot oil may be used [10]. The former may damage the channel connection and safety may be an issue after long-term use. Also, the latter may not be energy-efficient due to the low heat transfer coefficient of the oil. Local mold heating using an electric heating element is sometimes used to assist in high mold temperature control, especially for a thin-wall product. However, this still requires extra design and tool costs [11]. In our recent investigation series [5, 6, 12], with the requirement of high heating rate and low energy consumption, we had suggested the application of induction heating combined with low coolant temperature for dynamic mold temperature control. Figure 1 shows the principle of induction heating for injection mold plate. In this method, after the part was rejected, the inductor will be moved to the gap of the core plate and the cavity plate. This coil will stand by that location for heating the mold to the target temperature. After that, the coil will be removed and the mold will close for the filling step of the melt. By experiment, the time of 3 s to 4 s were needed for the mold surface temperature to increase from 110 ºC to 180 ºC and 200 ºC. The shorter heating time required for induction heating is due to the fact that the heat generated from induction is basically appeared on the mold surface, about 0.1 mm in depth, due to the skin penetration of the electromagnetic wave. In that case, the induction heating speed was about 30 ºC/s. Figure 1. Induction heating for injection mold plate. 410

Effect of 2D and 3D coil on the dynamic mold temperature control by induction heating The heating rate of induction heating method is total satisfy the requirement of the injection mold field. However, the application of induction heating is still quite complicated. There are many aspects that had a big influence on the induction heating process. The most important element in the induction heating system is the induction coil, because it impacts strongly on the heating effect as well as the temperature distribution of mold surface. For improving the induction heating period in injection molding cycle, this research will focus on the geometry design of the induction coil. This study will make comparison of heating effect with two types: the 2D coil and the 3D coil. In addition, the simulation and the experiment will be compared for verifying the accuracy of simulation results. 2. SIMULATION AND EXPERIMENTAL WORKS The mold temperature control process using external coil induction heating consists of an induction heating machine (IHTC-02) from INER Technology Co., LTD., a water mold temperature control system, a control and monitoring unit for operating the heating / cooling process and observing the mold temperature change, a mold plate (32 100 100 mm 3 ), and an externally coil system. The induction heating machine supports a high-frequency current flows through the conductor and the mold plate with a full power of 80 kw. This machine can support a maximum current of 1500 A, and the frequency of 75 khz. Figure 2a shows the mold design with the cooling channel insert system. This system controls the plate temperature, which includes pre-heating the plates to the initial temperature at the beginning of the experiment, and cooling them after the heating period by receiving the water from the mold temperature control. During each case of the experiment, the mold surface temperature will be measured and collected at points T1, T2 and T3. The location of these measuring points is shown in Figure 2b. In this study, there are two types of coil were designed: 2D and 3D coil. The coil design is based on the mold plate size. The coil dimension and the heating position of coil are shown in Figure 3. The inductor coil has the diameter of 8 mm. With both designs, the distance from the coil to the mold surface will be set at 3 mm. To cool the coil, a hollow channel is fashioned inside each coil. The coils are made of copper. To observe temperature at the plate surface, an infrared thermal imaging system (Avio NEO THERMO TVS-700) and thermal couples were used to measure the mold temperature. The experimental results were collected to verify the simulated predictions. In this study, the mold plate will be pre-heated to 40 C by the 40 o C water flows through the cooling channel. The induction heating machine will then be turned on to heat the mold surface. The heating rate and temperature distribution of the mold surface will be observed by the infrared camera and the sensors. All material properties are shown in Table 1. In all cases, the mold plate made of stainless steel 420 was used to study the effect of coil design on the heating rate and the temperature distribution. Because the induction heating has a high heating rate, therefore, in every case, by experiment and simulation, the temperatures at points T1, T2 and T3 will be collected after 2 s of heating. These results will be compared to study the differences in heating rate and temperature distribution when the coil design was changed. In this study, with the same heating parameters and material properties of experiment, the ANSYS software will be used for running the simulation of the induction heating process. After that, the simulation results will be compared by the experiment result to estimate the accuracy. The mesh model of the 2D coil and the mold plate were shown in Figure 4. 411

Phạm Sơn Minh Figure 2. Mold design (a) and temperature measurement point (b). Physical property Density Figure 3. The coil designs. Table 1. Material properties. Electrical Resistivity Relative Permeability (µ) Specific heat Thermal Conductivity Unit Kg/m 3 Ωm - J/kg K W/m K Air at 25 o C 1.18-1 1000 0.0256 Stainless steel 420 (ISO 683/134) 7700 5.50E-07 200 448 14 Copper (Cu) 8940 1.71E-07 0.99 392 400 412

Effect of 2D and 3D coil on the dynamic mold temperature control by induction heating Figure 4. The simulation mesh model of 2D coil. 3. RESULTS AND DISCUSSION Comparisons of heating temperature using a 2D and 3D coil with the initial mold temperature of 40 o C are illustrated in Figures 5 and 6. By experiment and simulation, Figure 5 shows the temperature of point T1, T2 and T3 with a heating time of 2 s using 2D coil. Base on this result, by experiment, after 2 s for heating, the temperature of point T1, T2 and T3 is 64 o C, 108 o C, 105 o C, respectively. This shows that temperatures at point T2 and T3 are almost the same. However, the heating effect at the center plate (point T1) is significant lower. The different temperature between 3 points is about 41 C. This is a trouble for the heating process in injection molding field because it will increase the warpage of the molding product due to the unbalance shrink in the cooling process. Figure 6 shows a comparison of temperature at point T1, T2 and T3 with the 3D coil in the simulation and experiment. The same boundary conditions with the 2D coil, in this case, the temperature of point T1, T2 and T3 are 89 o C, 78.5 o C, 66.1 o C, respectively. Although the max temperature in this case is lower than the case of 2D coil, but the temperature difference between three points was decreased to 23 C. This improvement is a great meaning in the injection molding field because it can reduce the part warpage clearly [12 14], moreover, with the heating rate of the 3D coil (about 13.0 o C/s to 24.5 o C/s), it can easily satisfy the target temperature of heating process in the injection molding field within a short time. For estimating the heating uniformity, the temperature distribution was observed by the infrared thermal camera in experiment. This result was compared with the simulation result in Figure 7. According to this figure, the lower temperature is located clearly at the center area of the heating surface when the 2D coil was used. This temperature distribution is very difficult to apply for the heating process in injection molding field, especially with the flat product. On the contrary, with the 3D coil, the heating effect appears as a rectangular area with the higher temperature locates at the center. This temperature distribution is a great improvement, and it could be easily applied for the heating step in the injection molding field. Figures 5, 6 and 7 also show that the simulation can predict the temperature distribution with different coil design. The improvement of temperature distribution with the 3D coil could be explained by the change of magnetic fluid. These cases were studied by simulation and the results were compared in Figure 8. At the center area of 2D coil design, the magnetic fluid is perpendicular with the molding surface, so, the heating effect is very weak. In the other hand, the magnetic fluid is parallel with the heating area when the 3D coil was used, so, the heating effect appears on all this face. The magnetic distribution is fit with the temperature distribution in Figure 7. 413

Phạm Sơn Minh Experiment Simulation 108 111 105 110.6 Temperature ( o C) 64 50.5 1 2 3 Point Figure 5. Comparison of temperature at T1, T2 and T3 on the surface of plate with the 2D coil design. Experiment Simulation Temperature ( o C) 89 91 78.5 80.1 66.1 74.04 1 2 3 Point Figure 6. Comparison of temperature at T1, T2 and T3 on the surface of plate with the 3D coil design. 414

Effect of 2D and 3D coil on the dynamic mold temperature control by induction heating Figure 7. Temperature distribution with the 2D coil (a) and 3D coil (b). Design 2D coil 3D coil Magnetic fluid B (T) Model Figure 8. The magnetic fluid comparison by simulation. 4. CONCLUSIONS In this study, a mold temperature control system using induction heating with two designs of coil was established. The advantage of 3D coil was evaluated. Using both experiment and simulation, temperature at the heating surface was investigated. Based on the results, the following conclusions were obtained. 415

Phạm Sơn Minh The heating rate of point T2 and T3 will be higher when the 2D coil was used. However, the temperature at point T1 is lower than T2 and T3. With this coil type, by simulation and experiment, the lower temperature area appears clearly at the center of the mold plate. In general, the heating rate of point T2 and T3 is slower when the 3D coil was used. On the contrary, the heating effect at the center point was significant improved with the 3D coil. In addition, the temperature difference between 3 points was reduced from 41 o C to 23 o C when the 3D coil was used. In both type of coil designs, the ANSYS simulation can predict quite accuracy the heating process with the temperature value of three points and the temperature distribution at the mold surface Acknowledgement. This research was supported by The Center-of-Excellence Program on Membrane Technology from the R&D Center for Mold and Molding Technology, Chung Yuan Christian University, Taiwan. REFERENCES 1. Jansen K. M. B. - Heat transfer in injection molding system with insulation layer and heating element, International Journal of Heat and Mass Transfer 38 (2) (1995) 309 316. 2. Yao D. G., Kim B. - Development of rapid heating and cooling system for injection molding applications, Polymer Engineering and Science 42 (12) (2002) 2471 2481. 3. Chen S. C., Chang Y., Chang Y. P., Chen Y. C., Tseng C. Y. - Effect of cavity surface coating on mold temperature variation and the quality of injection molded parts, International Journal of Heat and Mass Transfer 36 (10) (2009) 1030 1035. 4. Chen S. C., Li H. M., Hwang S. S., Wang H. H. - Passive mold temperature control by a hybrid filming-microcellular injection molding processing, International Journal of Heat and Mass Transfer 35 (7) (2008) 822 827. 5. Chen S. C., Jong W. R., Chang Y. J., Chang J. A., Cin J. C. - Rapid mold temperature variation for assisting the micro injection of high aspect ratio micro feature parts using induction heating technology, Journal of Micro Mechanics and Micro Engineering 16 (9) (2006) 1783 1791. 6. Chen S. C., Peng H. S., Chang J. A., Jong W. R. - Simulation and verification of induction heating on a mold plate, International Communications in Heat and Mass Transfer 31 (7) (2004) 971 980. 7. Chang P. C., Hwang S. J. - Simulation of infrared rapid surface heating for injection molding, International Journal of Heat and Mass Transfer 49 (21 22) (2006) 3846 3854. 8. Yu M. C., Young W. B., Hsu P. M. - Micro injection molding with the infrared assisted heating system, Materials Science and Engineering A 460 461 (2007) 288 295. 9. Chen S. C., Chien R. D., Lin S. H., Lin M. C., Chang J. A. - Feasibility evaluation of gas assisted heating for mold surface temperature control during injection molding process, International Communications in Heat and Mass Transfer 36 (8) (2009) 806 812. 10. Chen S. C., Chang N. T., Chen Y. C., Wang S. M. - Simulation and application of injection compression molding, Journal of Reinforced Plastics and Composites 18 (8) (1999) 724 734. 416

Effect of 2D and 3D coil on the dynamic mold temperature control by induction heating 11. Lin Y. W., Li H. M., Chen S. C., Chen C. Y. - 3D numerical simulation of transient temperature field for lens mold embedded with heater, International Communications in Heat and Mass Transfer 30 (9) (2005) 1221 1230. 12. Chen S. C., Lin Y. W., Chien R. D., Li H. M. - Variable mold temperature to improve surface quality of microcellular injection molded parts using induction heating technology, Advance in Polymer Technology 27 (4) (2008) 224-232. 13. Tarng S. H., Tan Y. J., Sapuan S. M., Sulaiman S., Ismail N., Samin R. - The use of Taguchi method in the design of plastic injection mould for reducing warpage, Journal of Materials Processing Technology 182 (1 3) (2007) 418-426. 14. Ozcelik B., Erzurumlu T. - Comparison of the warpage optimization in the plastic injection molding using ANOVA, neural network model and genetic algorithm, Journal of Materials Processing Technology 171 (3) (2006) 437-445. TÓM TẮT ẢNH HƯỞNG CỦA CUỘN DÂY 2D VÀ 3D ĐẾN QUÁ TRÌNH ĐIỀU KHIỂN NHIỆT ĐỘ CHO KHUÔN THEO PHƯƠNG PHÁP CẢM ỨNG TỪ Pham Son Minh Đại học Sư phạm Kỹ thuật TP. HCM, 01 Võ Văn Ngân, Quận Thủ Đức, TP. HCM Email: minhps@hcmute.edu.vn Phương pháp gia nhiệt bằng cảm ứng từ (Electromagnetic induction heating) có nhiều ưu điểm như: tốc độ gia nhiệt nhanh, tiết kiệm năng lượng và hầu như không gây ô nhiễm môi trường. Hiện nay, đây là một trong những phương pháp hiệu quả và tiết kiệm nhất trong quá trình gia nhiệt bằng điện năng. Trong nghiên cứu này, bằng phương pháp thực nghiệm và mô phỏng, thiết kế 2D và 3D của cuộn dây gia nhiệt (Induction coil) được sử dụng nhằm đánh giá khả năng gia nhiệt cho bề mặt của khuôn. Với cuộn dây 2D, thời gian gia nhiệt 2 s, nhiệt độ bề mặt khuôn đã tăng từ 40 o C đến 108 o C. Tuy nhiên, vùng nhiệt độ thấp vẫn tồn tại tại trung tâm của bề mặt khuôn. Ngược lại, với thiết kế 3D, nhiệt độ cao nhất tại cuối quá trình gia nhiệt là 89 o C, và vùng nhiệt độ thấp đã được khắc phục. Từ khóa: khuôn phun ép, điều khiển nhiệt độ khuôn, gia nhiệt bằng từ trường, thiết kế cuộn dây gia nhiệt. 417