THESE INSTRUCTIONS MUST BE READ FULLY BEFORE COMMENCING INSTALLATION.

Similar documents
HIT Centrifugal In-Line Fan

HHWCH51 Galvanised Hot Water Coil Heater

ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T

POWERPLUS SPP Installation & Maintenance

RAPTOR SPA Installation & Maintenance

MINIFLOW SMF Installation & Maintenance

Installation and Wiring Instructions

Lo-Carbon Quadra SELV

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Lo-Carbon Quadra Centrifugal Fan

TWINFLOW STDR Installation & Maintenance

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Panel Fan Series Operators Manual (Galvanized and Polymer)

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Centrif Duo & Centrif Duo Plus

100 FLUEBOOST

Panel Fan Series Operators Manual (Galvanized and Polymer)

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

XB-EFA-8L-BK & XB-EFA-8R-BK

heat stress & the dairy cow

RAPTOR COOLER SRC Installation & Maintenance

SUPER T WALL FANS. Installation and Wiring Instructions

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

AHU INSTALLATION & OPERATION MANUAL

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

Silhouette Installation and Wiring Instructions

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

CECx Destratification Fan

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH


INSTRUCTIONS AND WARRANTY

AP-EH500-L/RQA9837. Installation Guide

CONVEYOR TOASTER MODEL QCS QCS Installation and Operation Instructions 2M-HG0657 Rev. D 6/13/05

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Matters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas. Wang Qiaoli

OPERATION MANUAL. RUSTIBUS 400 ELECTRIC 3 Phase 220/380/440 V - 50 or 60/50/60 Hz. 3 x 380/440 V - 50/60 Hz.

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon Quadra Centrifugal Fan

AXUS - SC Short Cased Axial Flow Fans Installation and Maintenance

FLUEBOOST. flueboost 350 gas fire model

Whole Room Dryer WRD, WRD/110

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

12/50 CENTRIFUGAL PUMPS FOR DC SUPPLY OPERATING INSTRUCTIONS

Lo-Carbon SELV Tempra

INDOOR USE ONLY. Installation and Maintenance XTRACTOR. (ESX) 1 and 3 phase, Direct Drive, Fans for indoor use

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

INSTRUCTIONS AND WARRANTY

OP40R 40cm Remote Control Pedestal Fan

Lo-Carbon T-series Window & Roof Models

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY


Spiral Dough Mixer. Instruction manual. Model: CP821

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages.

Zip Econoboil 1.5 litre White Zip Econoboil 3.0 litre White Zip Econoboil 5.0 litre White Zip Econoboil 7.

V80-H Multistage Pump Instruction Manual

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

AXPR Wall Mounted Axial Panel Fans

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

100 Series Maxi Internal Filters

INSTRUCTIONS AND WARRANTY

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

Installation Instructions Wall Ovens

Installation & User Instructions:

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

INSTRUCTIONS AND WARRANTY

READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

16 Ultiflame Inset Electric Fire

Optimax Refrigerated Retail Merchandisers

Wilo Top S Wet Rotor Circulation Pumps. Engineering Specification

MEV-DC. Continuous Mechanical Extract Ventilation Units Installation and Maintenance. Figure 3. Fixing screw hole.

ClimaGuard Outdoor Heat Exchanger All Models

installation and operation manual for Hunter Ceiling Fans

Colorado SCR. Electric Towel Radiator Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

INSTALLATION AND USER INSTRUCTION GUIDE. Model (s) Electric Heater Model No s FRER**ME2 / FSER**ME2 / FMER**ME2. ** Denotes case colour / finish

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

Survey of electrical equipment installed in hazardous areas on tankers

Simply Silent Contour 4 (100mm) Axial Extraction Fan

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Mobile Evaporative Cooler EVA-12

Instructions for the Use and Care and Installation of ORU52X ORU70X. Undermount Rangehoods CONTENTS

Long Case Axial Fan. Installation and Wiring Instructions V/1/50Hz & V/3/50Hz

3KW ELECTRIC FAN HEATER

Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch. IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

SAX. Window & Wall Fans

Owner's Manual RSL-2700 GRAPHIC LAMINATION PRODUCTS

5KW ELECTRIC FAN HEATER

Submersible Grinder Pump Type ABS Piranha S10 - PE125

92 RAILWAY ST. SEAFORTH, ONTARIO CANADA, N0K 1W0 TEL: ABSOLUTE AIR INSTALLATION MANUAL

Mini. Level Control systems For Manual Sump Pumps up to 750W 1 or 2 Pump Systems

Transcription:

HV Belt Drive Fan Installation and Maintenance Instructions. THESE INSTRUCTIONS MUST BE READ FULLY BEFORE COMMENCING INSTALLATION. Owner / installer: The life of this apparatus and its efficiency will be increased if its use and maintenance is carried out in accordance with these instructions and current statutory requirements. The installation and initial adjustments should be carried out by a qualified and competent technician. Hydor Limited should be consulted before substituting or fitting parts from another manufacturer. It is the responsibility of the installer to verify that the installation is in accordance with the following standards and the owner is given the current User s Manual. Any modifications to the fan or its installation, even the smallest modification, change or elimination of security components or pieces that influence the efficiency or loss of ventilation, will result in the CE Certification and Hydor s warranty being cancelled. Single Phase Model Speed r/min Supply V-Ph-Hz Power kw FLC Amps Start Amps Blade Mattl. Weight kg Weight kg incl. Louvre HV800 530 230-1-50 0.750 4.5 14.3 st.st 31 44 HV1000 600 230-1-50 0.750 5.4 14.9 st.st 40 50 HV1250 410 230-1-50 1.100 7.2 25.7 st.st 50 70 HV1250A 425 230-1-50 1.100 7.5 25.7 ali. 50 70 HV1250 425 230-1-50 1.500 8.4 29.5 st.st 52 72 HV1500 360 230-1-50 1.500 9.4 33.0 st.st 55 85 HV2000 375 230-1-50 1.500 10.0 35.0 st.st 75 100

Three Phase Model Speed r/min Supply V-Ph-Hz Power Watts FLC Amps Start Amps Blade Mattl. Weight Kg Weight Kg incl. Louvre HV800 530 400-3-50 0.750 2.0 5.9 st.st 32 44 HV1000 600 400-3-50 0.750 2.6 7.8 st.st 40 50 HV1250 410 400-3-50 1.100 2.89 8.7 st.st 50 70 HV1250A 425 400-3-50 1.100 2.89 8.7 ali. 50 70 HV1250 425 400-3-50 1.500 3.2 9.6 st.st 52 72 HV1500 360 400-3-50 1.500 3.6 10.8 st.st 55 85 HV2000 375 400-3-50 1.500 3.8 12.5 st.st 75 100 1. Description 1.1 It is important these Installation and Maintenance Instructions are fully adhered to. 1.2 Full details of the unit supplied are shown on the product nameplate. If in doubt about any detail contact Hydor or its agents for clarification. 1.3 All electrical installations must be carried out by suitably qualified and competent personnel in accordance with all current statutory requirements. 1.4 These instructions cover only the Hydor product and do not include the supply or installation of any safety equipment that may be required e.g. proper electrical isolation. 1.5 Any declarations made by Hydor about product installation and safety, are dependent on the fan unit being used within installations which themselves meet the requirements of the relevant Standards and Directives of your region. 1.6 The fan unit is designed for use in an ambient temperature of up to 50 C and 95% relative humidity. The fan unit is not suitable for corrosive or explosive atmospheres. 1.7 The installer should provide easy access to the fan to facilitate future maintenance. 1.8 The installer should ensure the fan unit is mounted slightly tilted forward at the top towards the outside of the building and adequately supported. Holes are provided in the base of the casing to assist drainage. 1.9 This product is not intended for the use of young children or infirm persons unless they have been dequately supervised by a responsible person to ensure that they can use the product safely. Young children should be supervised to ensure that they do not play with the appliance.

WARNING The fan unit must be isolated from the power supply during installation and maintenance. The fan must be earthed in accordance with the local regulations. 2. Installation 2.1 Upon receipt, the fan unit should be visually inspected to check for any damage. Ensure that the impeller is free to rotate. 2.2 If there are any queries concerning the fan unit, HYDOR should be contacted prior to installation. air space, in front and behind the fan. A minimum of 2 metres is required. 2.3 If the unit is to be suspended, attach a chain to each eyebolt using separate D shackles for each chain. Form a V using two chains [one pair in front and one pair rear] and two small D shackles attached to one large D shackle each. In some instances it will be beneficial to suspend the fan leaning forward by adjusting the chains to direct the air downwards. NOTE Chain and D-shackles are not provided. Ensure that chain used will support weight of unit. Additionally, in some instances using long chains may cause a pendulum effect to develop; an additional check chain or rope will prevent this. 2.4 Where a fan is installed in a wall of the building, ensure that the access to the terminal plate and panel is available. Secure the fan unit using angled steel to fix to a surrounding wall. NOTE Ensure the unit is installed square; failure to do so may result in poor operation of the back-draught shutter blades. 2.5 Check the details on the motor rating plate to ensure that the correct power supply (voltage, frequency). 2.6 Eyebolts are provided as extras; for units which are to be suspended. 2.7 Refer to the appropriate wiring diagram. Means for electrical disconnection must be incorporated in the wiring installation in accordance with the relevant wiring and electrical regulations. Ensure that all earth connections are made and secure. Fuses/circuit breakers are used to provide short circuit protection only. A starter panel with overload protection must be fitted to protect the motor. 2.8 If the fan is being used through a speed control device, either electrically or electronically, refer to the relevant control device instructions before commencing installation.

3. Operation 3.1 Before power is supplied to the unit, check that the wiring is correct as per the fan connection diagram and control instructions [If fitted]. 3.2 At initial start-up, check that the impeller rotation and airflow direction is correct. 3.3 Check that the motor amperage does not exceed the nameplate rating at full speed and the electrical switch-gear is correctly sized using Hydor technical information. 4. Fan Maintenance 4.1 Inspection of the fan unit at least every 6 months is recommended to ensure that the motor, fan blades and supporting guards, are clean. Any build-up of dust deposits should be removed using a non-abrasive cleaner. 4.2 All fastenings should be checked for tightness. In addition, all rotating items should be checked. 4.3 Bearings are of the sealed for life variety and will not need a detail inspection. 4.4 Belt tension should be checked after 2-3 days use (48-72 hours usage). Allow 15-20mm deflection for the correct tension. Please note over tensioning will dramatically affect the longevity of the unit. WARNING Only a suitably qualified and competent person may carry out maintenance after the electrical supply has been isolated. Particular care must be taken when automatic switching controls are used.

5. Wiring Diagrams W2 U1 U2 V1 V2 W1 ALL FANS COME PRE-WIRED, N - BLUE 220V TO 240V 1Ph 50 HZ SUPPLY L - BROWN E - GREEN / YELLOW WITH FLEXIBLE CABLE W2 U1 U2 V1 V2 W1 ALL FANS COME PRE-WIRED, L2 - BLACK L1 - BROWN 380V TO 415V 3Ph 50Hz SUPPLY L3 - GREY E - GREEN / YELLOW WITH FLEXIBLE CABLE

Notes

Notes

Guarantee Hydor or its agents will, within a period of one year from the date of dispatch from their works, at its option, replace any goods, which are proven to have defects as a result of defective materials or workmanship. The goods must be inspected by a Hydor official and if necessary returned, with a Returns Note Number, carriage paid, for further examination. Hydor Ltd Hydor Unit 8, Parkers Close, Downton Business Centre, Downton, Salisbury, Wiltshire, SP5 3RB, UK Tel: +44 (0) 1725 511422 Email: info@hydor.co.uk Web: www.hydor.co.uk idealair group Unit 1, Building 1, Sydney Corporate Park, 85 O Riordan Street, Alexandria NSW 2015 Tel: +61 (02) 8073 3310 Fax: +61 (02) 8073 3320 Email: info@idealairgroup.com.au AMS 11 Ingrid Road, Montague Gardens, 7442 Cape Town, Western Cape Tel: +27 (0) 21 552 1077 Fax: +27 (0) 21 552 2797