Experimental study of operation performance of a low power thermoelectric cooling dehumidifier

Similar documents
FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

DESIGN AND FABRICATION OF A PORTABLE REFRIGERATOR BASED ON PELTIER EFFECT

Performance Analysis of Domestic Refrigeration System with Thermoelectric Module

COMPARISON OF THE EXPERIMENTAL PERFORMANCE OF A THERMOELECTRIC REFRIGERATOR WITH A VAPOUR COMPRESSION REFRIGERATOR

GAS FREE REFRIGERATOR USING PELTIER MODULE

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Experimental study of a novel dew point indirect evaporative cooler

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Solar Power Solid State Refrigeration

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

International Engineering Research Journal Performance assessment of multistage thermoelectric cooling module based refrigerator

Purdue e-pubs. Purdue University

Design and Experimental Investigation of Portable Solar Thermoelectric Refrigerator

Journal of Environmental Research And Development Vol. 6 No. 4, April-June 2012

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger

A study of Transient Performance of A Cascade Heat Pump System

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

SOLAR POWERED AIR CONDITIONING

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

COMPARATIVE ANALYSIS OF SINGLE AND DOUBLE EFFECT LiBr-WATER ABSORPTION SYSTEM

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

Performance Analysis of Solar Assisted Cascade Refrigeration System of Cold Storage System

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Design and Analysis of Thermoelectric Refrigerator

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Experimental study on mass transfer comparison of two liquid desiccants aqueous solutions

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Research Article Analyzing the Heat Transfer Property of Heat Pipe Influenced by Integrated Cooling Apparatus

SOLAR WATER DISTILLATION BY USING WATER IN THE INNER GLASS EVACUATED TUBES

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Experimental Study of Heat Transfer in a Container Filled with Water and Cooled by a Peltier Device

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

SIMULATION OF A NEW TYPE GAS-FIRED AIR-COOLED AIR-CONDITIONER. Lin Wang, Xing Xu, Aihua Ma, Yonghui Guo and Xiwen Zhou

American International Journal of Research in Science, Technology, Engineering & Mathematics

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

COMPRESSOR LESS SOLAR REFRIGERATOR

Thermal Performance of a Loop Thermosyphon

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

Best Row Number Ratio Study of Surface Air Coolers for Segmented Handling Air-conditioning System

Wearable cooling system to manage heat in protective clothing

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

Review on Vapour Compression-Thermoelectric Hybrid Refrigeration system

Adsorption refrigeration system using waste heat

Experimental Study on Performance of Double pipe Length on Instantaneous Air Source Heat Pump Water Heater. Yin Shaoyou 1, a

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

EXPERIMENTAL INVESTIGATION OF THERMOELECTRIC AIRCONDITIONER USING SEEBECK MODULES

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

DESIGN, ANALYSIS AND FABRICATION OF THERMOELECTRIC COOLING AND HEATING SYSTEM FOR WATER DISPENSER

Global Journal of Engineering Science and Research Management

Characterization of a Heat Sink with Embedded Heat Pipe with Variable Heat Dissipating Source Placement for Power Electronics Applications

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Performance Analysis of a Miniature-Scale Vapor Compression System for Electronics Cooling: Bread Board Setup

Cost-Effective COP Enhancement of a Domestic Air Cooled Refrigerator using R-134a Refrigerant

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

To investigate the surface properties for increasing efficiency of solar water heater

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

Effect of Heat Exchanger Configuration on the Performance of Joule-Thomson Refrigerators

Falling Film Heat Exchangers for Solar Water Heaters

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Performance investigation of Air-conditioning system using ejector as expansion device

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Keywords: Thermo-Electric Module, Peltier Effect, Solar Energy, Solar Cells, Coefficient of Performance.

Efficiency of Non-Azeotropic Refrigerant Cycle

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

A Design of Thermoelectric Cooler and Optimization

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

STUDY OF PERFORMANCE AND POSSIBLE CONFIGURATION OF HYBRID AIR CONDITIONING SYSTEM WITH AND WITHOUT COMBINED PELTIER MODULE AND EARTH HEAT EXCHANGER.

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

DEEPAK PALIWAL, S.P.S.RAJPUT

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

Modeling and Testing of an R-23/R-134a Mixed Refrigerant System for Low Temperature Refrigeration

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Transcription:

INTERNATIONAL JOURNAL OF ENERGY AND ENVIRONMENT Volume 1, Issue 3, 2010 pp.459-466 Journal homepage: www.ijee.ieefoundation.org Experimental study of operation performance of a low power thermoelectric cooling dehumidifier Wang Huajun, Qi Chengying School of Energy and Environment Engineering, Hebei University of Technology, Tianjin, China. Abstract The present work was performed to apply thermoelectric technology to a low power dehumidifying device as an alternative to the conventional vapor-compression refrigeration systems. The experimental prototype of a small-scale thermoelectric dehumidifier (TED) with rectangular cooling fins was built and its operation performance was studied experimentally. The results showed that the TED experienced two typical thermodynamic processes including the cooling dehumidification and the isothermal dehumidification, where the latter was dominated. It was found that there existed a peak during the variation of the average coefficient of performance (COP) as a function of the input power of the thermoelectric module. Under the present experimental conditions, the COP of the TED reached the maximum of 0.32 and the corresponding dehumidifying rate was 0.0097 g/min, when the input power was kept at 6.0 W. The rapid elimination of condensed liquid-drops on the cooling fins amounted on the thermoelectric module is a major approach to improving the operation performance of the TED. Copyright 2010 International Energy and Environment Foundation - All rights reserved. Keywords: Cooling dehumidification, Thermoelectric module, COP, Dehumidification rate. 1. Introduction For the indoor thermal comfort of buildings, the relative humidity is a key control parameter. At present, there exist a number of dehumidifying devices based on the traditional vapor-compression technology. Though these devices are widely applied, they still have many problems to be solved, such as high noise level, strong compressor vibration, and excessive weight and so on [1-2]. In fact, what s more important is the extensive use of CFCs or HCFCs, which has a great negative impact on the present crisis of energy and environment [3].Under this background, it is required to seek for other clean dehumidifying approaches. Thermoelectric cooling technology is just the case in point, which is based on the Peltier effect of semiconductor materials [4]. At present, the thermoelectric cooling technology has been developed rapidly, as an alternative to the conventional systems based on the vapor-compression refrigeration cycles. For the thermoelectric dehumidification, however, only a few studies were performed. In fact, thermoelectric dehumidifiers have a promising potential in the situations where both a lower power and a smaller space are required. Such applications can be seen in the space crafts, submarines, robots, tunnels, and industrial control cabinets and so on [5-6]. In previous studies, Chen [7] presented a TED with an improved fin heat exchanger, reaching a COP ranging from 0.12 to 0.29. Sumrit [8] tested the performance of a TED in a residential apartment, and obtained a COP of 0.27. In fact, except the difference in the thermoelectric module materials, the better performance of the TED depends mainly on

460 International Journal of Energy and Environment (IJEE), Volume 1, Issue 3, 2010, pp.459-466 an optimal layout of heat transfer surfaces. However, too much complex controls on heat transfer usually mean a higher construction cost of TEDs, which may reduce the feasibility in practical applications. The purpose of this work was to test the operation performance of the TED, and to obtain the relationship between the COP and the input power, which is helpful for the optimal design of similar TEDs. 2. Experimental system and procedure 2.1 Experimental setup Figure 1 shows the experimental setup of a small-scale TED. It mainly consisted of a closed cabinet, a thermoelectric module, a DC power meter, a humidifier, a humidiometer, temperature sensors, and a data acquisition system. The cabinet made of organic glass plates was used to simulate a small room. The cabinet was cube-shaped, with 400 mm in length, 400 mm in width, and 400 mm in height. A TEC- 12705 type thermoelectric module made of BiTe was used to provide a cold source for dehumidification. The module was 40 mm in length, 40mm in width, and 4mm in thickness, and its maximum working voltage and current were 15 V and 4 A. In order to enhance heat transfer, two rectangular fin heat exchangers were amounted on the heat and cold side of the thermoelectric module, with an extended area of about 91 cm 2 and 128 cm 2, respectively. A 2.4W axial fan for forced convection was amounted on the fin heat exchanger of the heat side of the TED. In order to eliminate the effect of contact resistances as possible, a thin layer of silicone grease with silver was covered on the heat-transfer surfaces of the TED. An adjustable WYJ-20 type DC power meter was used to electrically driven the thermoelectric module. Its maximum voltage and current output were 20 V and 10 A, respectively. The relative humidity inside the cabinet was measured by a HT-3005A type humidiometer with ± 1% accuracy installed at the middle of the cabinet. The temperatures of the cabinet and heat/cold fin heat exchangers were measured by copper- constantan thermocouples with ± 0.1 o C accuracy. The temperature data were recorded by a HP 34970A type recorder. All measuring sensors were calibrated carefully during the experimental preparation. The ambient atmospheric pressure was measured by a mercury manometer. According to the Chinese Code for Design of Heating Ventilation and Air Conditioning (GB 50019-2003), the allowable indoor relative humidity should range from 40 % to 65 % in summer and from 40 % to 60 % in winter. Therefore, in this experiment, the lower limit of the relative humidity was set as 40 ±1 %, and the upper limit was set as 98 ±1 % to simulate the situation with a high humidity environment of buildings. Before the experiment, the cabinet was humidified to a high relative humidity by a humidifier. After 10 min, the DC power supply of the thermoelectric module was connected. During the dehumidifying process, the variations of the temperature and relative humidity were recorded at an interval of 5 min. Ambient monitoring meters Thermocouple wires Camera Thermoelectric module Computer Humidity sensor Cold-side fins Cabinet Cooling fan Heat-side fins Data recorder humidifier DC power meter Figure 1. Schematic diagram of the experimental setup of a TED

International Journal of Energy and Environment (IJEE), Volume 1, Issue 3, 2010, pp.459-466 461 2.2 Experimental data reduction In order to evaluate the performance of the TED, the COP is defined as Q COP c = P P TE + F (1) where P TE is the power of the thermoelectric module (W), and P F is the power of the cooling fan(w). The total heat-transfer rate (Q c ) of the fin heat exchanger on the cold side of the TED is calculated as ( ) Q = h A t t + m H (2) c c c o c w c where h c is the coefficient of convective heat transfer (W/m 2 K), A c is the heat transfer area (m 2 ), t o is the temperature at the middle of the cabinet ( o C), t c is the average temperature of cold fins ( o C), and H c is the latent heat of condensation (J/kgK). The dehumidifying rate (m w, kg/s) is calculated as m m ( φ φ ) a 1 2 w = (3) T where m a is the mass of the wet air inside the cabinet (kg), T is the dehumidifying period (s), Φ 1 and Φ 2 are the relative humidity before and after dehumidification (%). According to the previous study by Bejan [9], the coefficient of convective heat transfer (h c, W/m 2 K) between adjacent fins and the ambient can be determined by hc λ H 0.25 = 0.517 Ra (4) where λ is the thermal conductivity of air (W/mK), H is the height of fins (m), and Ra is the dimensionless Rayleigh number, and its definition and calculations can be seen in the previous studies by Bejan and Cengel [9-10]. 3. Results and discussion 3.1 The analysis of the dehumidifying process of the TED Figure 2 shows a typical dehumidifying process of the TED, when the input power of the thermoelectric module is 5.5 W. It can be seen that, except the first 10 min, the average temperature of heat-side fins as well as the cabinet kept relatively steady during the dehumidifying process. The average temperature of cold-side fins appeared a slowly decreasing tendency, and finally reached a steady state. It was also found that the relative humidity experienced two accelerating stages (i.e.98-90% and 70-50%) and two decelerating stages (i.e.90-70% and 50-40%). This phenomenon is related with the condensing behavior of cold-side fins, which is discussed in the later section. The variation of the relative humidity shown in Figure 2 can also been plotted in the enthalpy-humidity diagram. As shown in Figure 3, the TED experienced two typical thermodynamic processes, including the cooling dehumidification and the isothermal dehumidification. During the cooling dehumidifying process from A to B, the variation of the relative humidity was weak, proceeding from 98 % to 90 %. In contrast, the isothermal dehumidifying process from B to C experienced a major change of the relative humidity varying from 90 % to 40 %. From the point of view of the dehumidifying period, the cooling dehumidification and isothermal dehumidification experienced 44 min and 145 min, respectively. Therefore, the isothermal dehumidifying process is dominated during the operation of the TED. The above experimental characteristics of the dehumidifying process depended on condensing heat transfer on cold-side fin heat exchangers of the TED. Figure 4 shows the photos of cold-side fins before and after dehumidification. It can be found that there existed many condensed liquid drops on the extended surfaces. At the bottom of local fins, there appeared the liquid-bridge phenomenon. Such an

462 International Journal of Energy and Environment (IJEE), Volume 1, Issue 3, 2010, pp.459-466 adherence of condensed liquid drops on the fin surfaces has an important role in the dehumidifying process of the TED, which can be further explained as follows. Temperaure ( o C ) 40 35 30 25 20 15 10 5 0 Cabinet temperature Cold fin temperature Heat fin temperature Relative humidity 100 90 80 70 60 50 40 Relative humidity (%) -5 0 20 40 60 80 100 120 140 160 180 200 Time (min) 30 Figure 2. A typical dehumidifying process of the TED Figure 3. The dehumidifying process in the enthalpy-humidity diagram

International Journal of Energy and Environment (IJEE), Volume 1, Issue 3, 2010, pp.459-466 463 (a) before dehumidification (b) after dehumidification Figure 4. Photos of cold-side fins before and after dehumidification At the initial dehumidifying process, the temperature of cold-side fins dropped rapidly, which promoted the vapor condensation inside the cabinet. This indicated that a number of liquid drops was created and adhered on the fin surfaces. Soon these liquid drops became a thin layer of liquid film, driven by the surface tension. Such a liquid film was a great thermal resistance and then led to a weak heat and mass transfer between the fin surfaces and the ambient inside the cabinet. As a result, the dehumidifying rate began to decrease, and this was the so-called first decelerating stage ranging from 90% to 70%. When the film became thicker and thicker, the runoff flow along the gravity direction was dominated. The fin surfaces became relatively clean again. At the same time, the temperature of cold-side fins still remained a steady low temperature close to 0 o C. Thus, the dehumidifying process began to accelerate for the second time. Repeatedly, when the liquid film on the fin surfaces became thick enough, the dehumidifying process experienced the second decelerating stage till the dehumidification was ended. From the analysis above, it can be seen that a rapid elimination of condensed liquid-drops on the cooling fins amounted on the thermoelectric module is a major approach to improving the performance of the TED. Such efforts can be realized by using superhydrophilic (SH) or super-water repellent (SWR) surfaces [11-12]. Related experimental work is expected to be reported in our later studies. 3.2 The analysis of the dehumidifying performance of the TED Figure 5 compares the dehumidifying processes under different input powers of the thermoelectric module. It can be seen the dehumidifying period depends strongly on the input power of the thermoelectric module. In this experiment, when the input power was 6.0 W, the dehumidifying period reached the minimum of 120 min. In contrast, for the input powers lower or higher than 6.0 W, the dehumidifying period showed an increasing tendency. For instance, the dehumidifying period was 180 min at 5.0W and 150 min at 7.0W, respectively. This result can be explained by the characteristics of thermoelectric module materials. For a thermoelectric module, the heat absorption from the ambient consists of two sources. One is from the Peltier effect, which is proportional to the current through the module. Another is from the Joule effect, which is proportional to the square of the current through the module [4]. When the input power is too low, the Peltier effect is weak, resulting in a low dehumidifying rate. On the contrary, when the input power is too high, the Joule effect is dominated, resulting in a high heat load imposed on the heat-cold heat exchangers. Once the heat generated can not be released into the ambient, the extra heat will be transferred by heat conduction towards the cold side, and finally weaken the condensing heat transfer on the fin heat exchanger. Therefore, for the minimum dehumidifying period, there is an optimal input power of the thermoelectric module.

464 International Journal of Energy and Environment (IJEE), Volume 1, Issue 3, 2010, pp.459-466 110 Relative humidity (%) 100 90 80 70 60 50 4.0W 5.0W 5.5W 6.0W 7.0W 8.0W 40 30 0 20 40 60 80 100 120 140 160 180 Time (min) Figure 5. Dehumidifying processes under different input powers of the thermoelectric module Figure 6 compares the variations of COP under different input powers of the thermoelectric module. It can be seen that the COP of the TED increases rapidly during the initial stage, then keeps a slowly growing tendency till reaching the maximum level, and finally drops quickly. For instance, when the input power was 6.0 W, the COP began to accelerate at 80 min, which was the start of the second accelerating stage shown in Figure 5, and reached the maximum of 0.32 at about 100 min, which was just the end of the second accelerating stage shown in Figure 5. For the most dehumidifying period, however, the COP remained an average level of about 0.17, about half of the maximum level. When the input power increased to 7.0 W and 8.0 W, the corresponding COP reduced to 0.26 and 0.20, respectively. This experimental phenomenon can fully reflect the working mechanism of the TED where the complex heat and mass transfer related with condensation on the cold-side fin heat exchanger is a critical influencing factor. Compared with the previous results obtained by Chen [7] and Sumrit [8], the present experimental COP was higher. 0.35 COP 0.30 0.25 0.20 0.15 4.0W 5.0W 6.0W 7.0W 8.0W 0.10 0.05 0.00 0 20 40 60 80 100 120 140 160 180 Time (min) Figure 6. Variations of COP under different input powers of the thermoelectric module

International Journal of Energy and Environment (IJEE), Volume 1, Issue 3, 2010, pp.459-466 465 Average COP 0.20 0.18 0.16 0.14 Average COP Average dehumidifying rate 6 5 4 3 Average dehumidifying rate (10-3 g/min) 0.12 4 5 6 7 2 8 Input power (W) Figure 7. Variations of the average COP and the average dehumidifying rate under different input powers of the thermoelectric module Figure 7 further shows the variations of the average COP and the average dehumidifying rate under different input powers of the thermoelectric module. In the present experiment conditions, the average dehumidifying rate was about 0.005 g/min at the input power of 6.0W, though the maximum reached 0.0097g/min. It should be noted that the performance of practical TEDs varies greatly in the present studies. A generally acceptable COP of TEDs ranges from 0.1 to 0.6[13]. In addition, Vian [14] established a numerical model of a TED. Through optimizing the heat transfer, a COP of 0.8 was obtained in the computation conditions. As far as the author s knowledge, this value is the highest in the available literatures. Therefore, compared with Vian s theoretical prediction, there is still a great space for the performance improvement of the present TED. In contrast, the COP of conventional dehumidifiers usually ranges from 0.7 to 1.3 [15]. On the other hand, at present the figure of merit (ZT) of most commercial thermoelectric materials is lower than 1.0. For instance, the ZT of BiTe used in this experiment was about 0.6. However, the value of ZT has been improved to 2.4 for some novel thermoelectric materials [16]. It can be expected that, with a continuing advance in the thermoelectric technology, the performance of the TED will be improved drastically. In summary, despite that the COP obtained by the present experimental setup is at a relatively low level, a lower power TED is of certain commercial interest. From the present experimental results, it can be seen that, during the use of thermoelectric cooling technology, the relative humidity can be controlled more accurately through an adjustable input power, which provides an important approach to improving the indoor thermal comfort of buildings. 4. Conclusion TEDs have a promising potential in the situations where both a lower power and a smaller space are required. The present work was performed to develop a low power TED as an alternative to the conventional vapor-compression refrigeration systems. From the experimental results discussed above, the following conclusions can be obtained: (i) The TED experienced two typical processes including the cooling dehumidification and the isothermal dehumidification, but the latter was dominated. The relative humidity experienced two accelerating stages and two decelerating stages. This phenomenon is related with the condensing behavior on the extended surfaces of the cold-side fin heat exchanger. (ii) There exists a peak during the variation of the COP as a function of the input power of the thermoelectric module. Under the present experimental conditions, the COP of the TED reached the maximum of 0.32 and the corresponding dehumidifying rate was 0.0097 g/min, when the input power was kept at 6.0 W. (iii) There is still a great space for the performance improvement of the present TED. The effective elimination of condensed liquid-drops on the cold-side fins is a major work in the future.

466 International Journal of Energy and Environment (IJEE), Volume 1, Issue 3, 2010, pp.459-466 Acknowledgements This work was supported by Program for Young Talents in Hebei University of Technology, and Natural Science Foundation of Tianjin (No. 07ZCKFSF00400). References [1] Bansal PK, Martin A. Comparative study of vapour compression,thermoelectric and absorption refrigerators. International Journal of Energy Research, 2000, 24(2), 93-107. [2] Alhazmy MM. Power estimation for air cooling and humidification using exergy analysis. International Journal of Exergy, 2006, 3(4), 391-401. [3] Riffat SB, Qiu G. Comparative investigation of thermoelectric air-conditioners versus vapour compression and absorption air-conditioners. Applied Thermal Engineering, 2004, 24(14-15), 1979-1993. [4] Rowe DM. Handbook of Thermoelectrics. Boca Raton, CRC Press, 1995. [5] Yang R, Chen G, Kumar AR, et al. Transient cooling of thermoelectric coolers and its applications for microdevices. Energy Conversion and Management, 2005, 46(9-10), 1407-1421. [6] Riffat SB, Ma Xiaoli. Thermoelectrics: a review of present and potential applications. Applied Thermal Engineering. 2003, 23(8), 913-935 [7] Chen S.Condensation analysis and improvement of a thermoelectric dehumidifier.m.a.sc. Thesis, National Cheng Kung University, 2001. [8] Sumrit I. Development of thermoelectric dehumidifier. M.A.Sc. Thesis, King Monkue University of Technology, 2003. [9] Bejan A, Tsatusaronis G, Moran M. Thermal design and optimization, Wiley, 1996. [10] Cengel YA. Heat transfer- a practical approach, McGraw-Hill, 1998. [11] Takata Y. Photo-induced hydrophilicity and its applications to phase change phenomena. Thermal Science and Engineering. 2002, 10(6), 31-38. [12] Takata Y, Tanaka K, Kaijima K, et al. Enhancement of heat transfer with liquid-vapor phase change by photo-induced hydrophilicity. Proceedings of the 33rd National Heat Transfer Conference, Japan, 1999. [13] Huang BJ, Chi CJ, Duang CL. A design of thermoelectric cooler. International Journal of Refrigeration.2000, 23(4), 208-218. [14] Vian JG, Astrain D, Dominguez M. Numercial modelling and a design of a thermoelectric dehumidifier. Applied Thermal Engineering. 2002, 22(4), 407-422. [15] Pietro M, Francesco M, Daniele P. HVAC dehumidification systems for thermal comfort: a critical review. Applied Thermal Engineering, 2005, 25(5), 677-707. [16] Rama V, Edward S, Thomas C, et al. Thin-film thermoelectric devices with high roomtemperature figures of merit. Nature, 2001, 413(6856), 597-602. H. Wang is Ph.D in Thermal Engineering from Tianjin University in 2008. He completed M.Sc and B.Sc in Engineering Thermophysics from Tianjin University in 2003 and 1998, respectively. At present, he is an associate professor of School of Energy and Environment, Hebei University of Technology. His work focus mainly on heat and mass transfer related with renewable energies, HV&AC, and energy saving of buildings. He has published over 20 research papers including 8 in the international journals. He takes as a reviewer of several international journals in the energy field. E-mail address: huajunwangl@126.com C. Qi is Ph.D in Thermal Engineering from Tianjin University in 1997. He completed M.Sc and B.Sc in Engineering Thermophysics from Tianjin University in 1988 and 1985, respectively. He is a professor of School of Energy and Environment, Hebei University of Technology. Since from 2005, he has taken as the dean of School of Energy and Environment of HBUT. His work focus mainly on heat and mass transfer related with renewable energies, HV&AC, and energy saving of buildings. He has published several research papers in the international journals. E-mail address: qicy@mail.hebut.edu.cn