INVENTORY. 1. Take out the device. 2. Unscrew the bottom of the device. 3. Remove the Carb Ring and Air Intake Grommet.

Similar documents
Energize the crystal, summon the fire. USER MANUAL. Read carefully before using the device and save these instructions.

(Place Logo from Lab here)

UV Lamp and Quartz Sleeve Replacement/Maintenance

Owner s Manual for the Passport Series Rooms PS 44 With SaunaLogic Control

HELO FAR-INFRARED CABIN INSTRUCTION MANUAL HSI 40 CE

HELO FAR-INFRARED CABIN INSTRUCTION MANUAL HSI10

INFRARED WOODEN SAUNA ROOM INSTRUCTION MANUAL IG-530 BH

HELO FAR-INFRARED CABIN INSTRUCTION MANUAL HSI80

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

ARLEY STEAM SHOWER ENCLOSURE

LEVENS STEAM SHOWER ENCLOSURE

INFRARED WOODEN SAUNA ROOM INSTRUCTION MANUAL IG-670EX/E300-CX

NEOSAUNA SERENITY SAUNA INSTRUCTION MANUAL Read all instructions carefully before using this wooden sauna room SKUS: SAU-SER-4C-B, SAU-SER-4C-C

AUTO-MATE LITHIUM ION

User s Manual. Electric Kettle Model MJ-EK5AEU (UK) Household Use

Red Alarm Indicator Light

INFRARED WOODEN SAUNA ROOM INSTRUCTION MANUAL IG-540BX/B400-X. Important: Please record your serial number here

FREWIN STEAM SHOWER ENCLOSURE

Instruction Sheet DANGER

Instruction Sheet DANGER

Hallmark Rooms HM 55C and HM 66C Owner s Manual with SaunaLogic Control and Bluetooth Sound System

S-Series 3 Person Infrared Sauna Touch Pad and Bluetooth IG-870-SH/S870 User Manual

Infrared sauna SUN S Pure Infra User Manual

S-Series 3 Person Infrared Sauna Touch Pad and Bluetooth IG-830-SH/S830 User Manual

Maintenance. Maintenance

User s Information Manual Models: ER152, ER202, ER252, ER302, and ER402

The GAK-800 Heated Exercise Gas Analyzer Accessory Kit

Dual Spin Mop Robot Cleaner

User manual Whirlpool

ECO SPA & POOL OWNERS MANUAL & INSTALLATION GUIDE

HOME FIRE SAFETY. Reference Guide

Electronic Pulse Massager

Carbon monoxide Knowing more

Instruction Sheet. VIQUA UVMAX Lamp and Quartz Sleeve Replacement

Daily Cleaning Instructions: KL1Plus

Whirlpool Bathtub Model Number: MT618

Please do not return this product to the retailer!!! If you find that you have any trouble with assembly or missing or damaged parts please contact

TRANQUILITY ADVANCED HEATING SYSTEM

Owner s Manual. Model PH050006

1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION 2. COMPOSITION/INFORMATION ON INGREDIENTS

MAGNETIC ELLIPTICAL TRAINER

Micro-Computer Induction Cooktop SR-964T INSTRUCTION MANUAL. Thank you for your purchase.

Introduction.3. What is Extreme Heat Condition 4. Effects of Extreme Heat on Health 5. I. Heat Cramps 5. Heat Exhaustion..6. III. Heat Stroke..

TAYAMA R. User Manual Watt Countertop Induction Cooker Model TIH-1500X. Tayama Appliance USA Inc.

Read this owner's manual thoroughly before operating the appliance and retain it for future reference. TYPE : PORTABLE AIR CONDITIONER

ultrasonic stain cleaner

Register your product and get support at. AC4076. User manual

Jennings Street School

Material Safety Data Sheet

Attention. Please handle this product with care and inspect it regularly to ensure it is in good working order.

Owner s Manual for the Passport Series Rooms PS 46 and PS 57 With Saunalogic Control

home use only in accordance with the instructions provided in this manual. Please read these instructions carefully and retain for future use

OWNER S MANUAL ONE-PERSON & TWO-PERSON SAUNAS WITH CERAMIC OR CARBON HEATERS

3 Macurco Carbon Monoxide Detector CM-16A

Model S-530 Coin Sorter / Value Counter Operating Manual

Checking the components Safety information Operating the product Other information

Quick Touch Pendant. Quick Touch Pendant. Battery

ELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS

CARBON MONOXIDE DETECTOR, i4h-co-m330

Unity 180 Premium Whirlpool 180/80/62 cm

Operating / User Manual

Lab Safety and Equipment

EVAPORATIVE AIR COOLER

Frequently Asked Questions About Carbon Monoxide Detectors

IMPORTANT SAFETY INSTRUCTIONS WARNING: When using electric appliances, basic

SharperImage.com T.E.N.S. Massager with Handheld Control Operating Manual

What is carbon monoxide (CO) and why do I need a carbon monoxide detector?

Z86 Safety-Plus Industrial Cleaner Concentrate

Safety Data Sheet. according to Regulation (EC) No 1907/2006 WICKES SMOOTH MASONRY

Control Series Operation Instructions Page 1. "Digi VII"

Operating instructions Page 12. Wine storage cabinet WKt

Safety Data Sheet. according to Regulation (EC) No 1907/2006. SECTION 1: Identification of the substance/mixture and of the company/undertaking

Operation and Maintenance of Aluminium Windows, Doors Screens and other Glazed products.

Revision date: 22/4/2016 Date of print: 11/5/2016 Version: 1 Language: en-ca,us Page: 1 of 8

Coway Air Purifier AP-1008DH

Model: AW600. Triple Action Humidifier. Winix Inc. 120 Prairie Lake Road U nit E East Dundee, IL USA

EMERGENCY PHONE: or (651) (24 hours)

USB Warming Gloves with Carbon Fiber Heating Elements Model No. MH-1000

SPECIMEN. Storm Secure. Production date. Batch number. Authorisation number: UK Contains 0.05g/kg (0.005% w/w) flocoumafen.

MAXI-FLO STAINLESS STEEL AND TITANIUM HEAT EXCHANGER FOR SWIMMING POOLS & SPAS INSTALLATION AND MAINTENANCE MANUAL

3M MATERIAL SAFETY DATA SHEET 3M(TM) Micropore(TM) Surgical Tape 1530, 1530S, 1530B, 153NS, /03/2006

Dual Channels - TENS Electronic Pulse Massager Unit Model No.: MT-5180

Congratulations on purchasing a bennett read Hydro.

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Industrial - Remote Reservoir Parts Cleaner Operator's Manual. Read and understand all labels, MSDS, and this instruction manual before use.

UPRIGHT FREEZER WHS-502FWEW1(E) WHS-502FWEB1(E) WHS-502FWESS1(E)

Model HD 3501 Part No High Pressure Washer Operator Manual

Kinsa Smart Ear ThermometerTM Instructions For Use

3M MATERIAL SAFETY DATA SHEET 3M(TM) Durapore(TM) Surgical Tapes Cat. #1538 and 1538S series 02/27/2006

Instructions for Use Spinal Punches IFU

Model CWA200 Owner s Manual

Contempo STAFF ROOM BUSINESS GUEST LAUNDRY Room Numbers

SPA HEATER INSTALLATION, OPERATION AND MAINTENANCE

SK SERIES INSTALLATION INSTRUCTIONS 1

3M MATERIAL SAFETY DATA SHEET 3M(TM) Transpore(TM) Surgical Tape Cat. # 1527 series, 1527S-1, 1527S-2 04/07/2006

Ionizer (Static Remover) STABLO-EX Instruction Manual

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

EMERGENCY PHONE: or (651) (24 hours)

Enteral Pump Instructions for Use To Assemble When the low

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Transcription:

INSTRUCTION MANUAL

INVENTORY 1. Take out the device. 2. Unscrew the bottom of the device. 3. Remove the Carb Ring and Air Intake Grommet. C. SUSCEPTOR HOLDER B. SUSCEPTOR D. CARB RING A. MOUTH PIECE I. ADAPTER E. AIR INTAKE TUBE (INSIDE DEVICE) H. CENTER DEVICE GROMMET 4. An itemized description of the Legend components are as follows: A. Mouth Piece B. Susceptor C. Susceptor Holder D. Carb Ring E. Air Intake Tube F. Air Intake Grommet G. U-Pipe H. Center Device Grommet (Pre-attached to the device) I. Adapter (Pre-attached to the device) J. Dab Tool K. Brush L. Power Adapter M. Bottom Plate N. Device F. AIR INTAKE GROMMET (INSIDE DEVICE) L. POWER ADAPTER G. U-PIPE J. DAB TOOL M. BOTTOM PLATE N. DEVICE K. BRUSH

ASSEMBLY 1. Insert the Air Intake Tube into the coil area (flanged side up). 2. Place the Air Intake Grommet inside the device and connect it to the bottom of the Air Intake Tube. COMPLETE GLASS AIR PATH 3. Insert the U-Pipe into the Air Intake Grommet and Center Device Grommet. Legend comes disassembled to ensure all glass components are protected during transport. Review the diagram above to see how the components fit together inside the unit and follow the steps on the following pages. 4. Screw Bottom Plate back into place. (Steps Continued on Next Page)

5. Place Susceptor in Susceptor Holder. HOW TO VAPE 6. Place Susceptor Holder in bowl on top of Carb Ring. 7. Place Carb Ring on top of bowl/coil area. USING THE DEVICE 8. Fill Mouth Piece with water slightly above the holes. 10. Connect Power Adapter to back of unit. 9. Place Mouth Piece onto adapter. 1. Have material ready on the end of the dab tool before proceeding. 2. Push Button. 3. Turn Button to desired power setting (as indicated by color). 4. Using the Dab Tool, put material into chamber and press against the susceptor. 5. Inhale. 6. Remove Dab Tool from the chamber. 7. Turn Carb Ring while inhaling to clear vapor from Mouth Piece. 8. Press Button to turn device off. 9. Exhale.

SETTINGS POWER LEVELS Legend has 6 power levels. Level 1 is the lowest power (coolest) and Level 6 is the the most power (hottest). The mouth piece will light up according to the power level selected. The color will pulse while adjusting between levels and turn solid once reaching the appropriate power level. Level 0 - Idle (No heat) Level 1 Level 2 Level 3 Level 4 Level 5 Level 6! ERROR MODES NO SUSCEPTOR DETECTED Legend will flash orange until susceptor is inserted. Legend will flash for 10 seconds and automatically shut down if no susceptor is detected. OVER TEMPERATURE Legend will flash orange 3 times then shut down until cooled completely. Remove susceptor and place in susceptor stand. UNIT MALFUNCTION Remains orange for 10 seconds, then device shuts down. APP The App unlocks full control of your Legend. You will also be able to update the software or firmware on the Legend as features and versions become available. 1. Go to lotolabs.com/app for links to the latest App. 2. Download and Install the App on your phone. 3. Open the App and follow the directions. BRIGHTNESS You can adjust the brightness of the lights on your Legend. 1. Press Button 2 times quickly to enter brightness adjustment. Legend will light up white. 2. Turn Button to adjust brightness level. 3. Press Button once to exit brightness adjustment. BLUETOOTH After downloading the app and following the directions, you can pair Legend with your phone. 1. Press and hold down Button on Legend. 2. Legend will enter pairing mode and flash a teal blue color. 3. The Legend will hold a solid teal blue color when the device pairs.

DEVICE CARE MICROFIBER WRAP Keep the microfiber away from dust and moisture, prolonged sun exposure, high-temperature environments as well as acidic and alkaline substances. CLEANING THE MICROFIBER WRAP 1. Only clean with water and mild detergent. 2. Use water that is not greater than 40 C to clean the product. 3. Avoid using petroleum or organic solvents. GLASS AIR PATH QUICK CLEANING 1. Wait for device to cool completely. 2. Insert brush or pipe-cleaner into air intake hole to clean. DEEP CLEANING 1. Wait for device to cool completely. 2. Remove Mouth Piece. 3. Remove Carb Ring with Susceptor and Susceptor Holder. 4. Unscrew Bottom Plate. 5. Remove U-Pipe and Air Intake Grommet carefully. 6. Use a cotton swab (Q-Tip) to clean Center Grommet and other glass mating areas. 7. Soak all parts in alcohol for at least 2 hours, overnight is suggested. 8. Clean glass parts with brush or pipe-cleaner. 9. Let dry. 10. Rinse with water and dry. 11. Follow assembly instructions, use the device, and repeat.! SAFETY AND WARNINGS Keep Legend and its components out of reach of children and pets. Do not operate Legend with the mouth piece off. Do not attempt to remove the susceptor from the induction coil until it has cooled completely. Do not use Legend if it appears to be damaged, broken, or operating in an unusual manner. Do not use Legend if it is unusually hot to the touch. Do not expose Legend to, or store your Legend in, extremely high or low temperatures. Do not store the Legend on or near heat sources. Do not use if it becomes immersed in any liquid. Do not use if you are a minor. Do not use this product if you have an allergy or sensitivity to inhalants. Do not use if you are pregnant or breastfeeding, have heart disease, diabetes, high blood pressure, asthma or any other serious medical condition. Seek medical attention if you experience symptoms such as nausea, vomiting, dizziness, diarrhea, weakness, or rapid head beat. Ingestion of small parts can present a choking hazard. Seek medical attention in the case of dizziness, drowsiness, accidental exposure, or if you feel unwell This product is not intended for the mitigation, treatment, or prevention of any disease or condition. This product is not intended for use with illegal substances.

WARRANTY Legend is covered by a limited 2-year manufacturer s warranty. Please visit lotolabs.com/warranty for details. Email: hello@lotolabs.com Website: lotolabs.com Copywrite 2018 Loto Labs Inc. All rights reserved. Loto Labs name, Legend name and associated taglines are trademarks of Loto Labs Inc. US and international patents pending. Patent: lotolabs.com/patent LOTOLABS.COM