Commissioning Worksheets (Part A-General) (W 1)

Similar documents
Worksheet for Small Commercial Air System Design

Indiana WX Oil Furnace Inspection Guide

Ventilation BCBC & Richard Kadulski Architect

(A) ft 3. cfm. cfm (Q

Ventilation BCBC 9.32 & Richard Kadulski Architect

TECHNICAL SPECIFICATIONS

1 Ventilation Checklist 1 Forced Air Systems SENTENCE (2)

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

Phase Two Change Proposal for the Next Edition of the Building Code: 2-CC-B POTENTIAL CHANGE TO ONTARIO S BUILDING CODE:

Mechanical Ventilation Checklists

1 Ventilation Checklist 1 Forced Air Systems SENTENCE (6)

Heat Recovery Ventilation

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC

Now In Production JULY 2008

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

MBPA Home Performance FIELD DATA COLLECTION FORM

Cooling Capacity CFM in. w.c. (125 Pa)

SHOE PALACE HUNTINGTON PARK M.200

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

SUBMITTAL SCHEDULE & DATA

Cooling Capacity CFM in. w.c. (125 Pa)

Wall Mounted Air Conditioners with Gas Heat Models AVGA

Boiler & Water Heater

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Indoor Air Quality Product Brochure.

EnergyMeasure HOME DATA COLLECTION FORM

Comfort, Quality and Efficiency.

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

Cooling Capacity CFM in. w.c. (125 Pa)

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

City of Duluth Festival Center 04/25

Cooling Capacity CFM range

HRV/ERV Performance Issues

Ruud Achiever Plus Series Multi-position Gas Furnaces

TECHNICAL SPECIFICATIONS

ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Capt. Tim s s Duct Design Mythbusters. The bitterness of poor quality is remembered long after the sweetness of low price is forgotten!

TECHNICAL SPECIFICATIONS

FG7T (C and L Series)

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

VERTICAL FAN COIL UNITS

Experienced Worker Assessment Blueprint HVAC - Heating, Ventilation and Air Conditioning

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

CHAPTER IV AIR DISTRIBUTION AND BALANCE

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

REPLACEMENT PARTS LIST

INDOOR AIR QUALITY KITS AND ACCESSORIES /2014. Supersedes 06/2014

b) Medium dwelling units that are not included in (a) above {small dwelling}, OR (c) below {large dwelling} Requires 3.5 credits

M2 Series Startup Form

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

TR Series - The Ultimate ERV

FEATURES AND BENEFITS

Ventilation Techniques. Topic 5 - Audio 53

GB Condensing Gas Boiler

Installation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant

TSTAT0201CW Recommended (sold separately)

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Rheem Classic Series Multi-position Gas Furnaces

A Better Boiler Just Got Better. Better Boilers. New Size Available. Express Setup. Load Status. User Setup. Installer Setup. Diagnostics.

KIC Air Curtains. Technical Guide

Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Energy Saving. Space Saving.

Model Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg)

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

LEED for Homes V4 Provisional Alternative Compliance Paths for the Canadian market March, 2017

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

Wt. Lbs Model Number (BTUH) Hz

Electric Heat Inspection Form Revised September 2012

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

Rheem Classic Plus Series Multi position Gas Furnaces

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

Ventilation for New Low-Rise Residential Buildings July 20, 2015

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

RG7D 1-Stage Heat Series

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

Installation Instructions

Ruud Achiever Series Multi position Gas Furnaces

TECHNICAL SPECIFICATIONS

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

48TM GAS HEATING/ELECTRIC COOLING UNITS

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

INDOOR AIR QUALITY KITS AND ACCESSORIES /12 Supersedes 05/12

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

Transcription:

Commissioning Wksheets (Part A-General) (W 1) Wallet card photocopy Inspection Authity: Signature: Date: Submitted F: ( Owner ) Name Address City Prov Postal Code Phone: Fax Commissioner: Phone: Fax Date: / By: ( Contract ) Name Address City Prov Postal Code Phone: Fax A.1 Wksheets required W.1 Wksheet 1, Part A: General: Required f all jobs W.2 a, b, c Wksheet 2, Part B: Fced Air Heating: F jobs with fced air heating systems W.3 a, b Wksheet 3, Part C: Hot Water Heating: F jobs with hot water heating systems W.4 Wksheet 4, Part D: Fced Air Cooling: F jobs with fced air cooling systems W.5 a b Wksheet 5, Part E: Ventilation System: Required f all jobs. W.6 Wksheet 6, Part F: Depressurization: Required f most part 6 and F326 jobs. A.2 Certification I certify that the HVAC systems have been commissioned accding to the requirements of the manufacturer s commissioning instructions, the wksheets checked below, and all applicable codes. W.1 W.2 a, b, c W.3 a, b W.4 W. 5 a b W.6 HRAI Certification #: Expiry Date: Signature: Fms available from: HRAI * 2350 Matheson Blvd. East * Suite 101 * Mississauga, Ontario * L4W 5G9 Reproduction in any fm by mechanical means is fbidden. ( Aug. 17 ) Copyright by: The Heating, Refrigeration and Air Conditioning Institute of Canada.

Commissioning (Part B-Fced Air Heating) (W 2a) B.1 Heating unit (Designed) B.2 Heating unit (Installed) make: make: fuel type: ng lp oil ele hp w other fan speed RPM: fan control settings: on F off F heat anticipat setting manufacturer A fuel type: ng lp oil ele hp w other fan speed RPM: fan control settings: on F off F heat anticipat setting A B.3 Befe start-up electrical polarity crect unit electrically grounded fuel lines connected and tested drain lines connected and trapped all shipping bracing (packaging) removed duct system complete registers and grills installed duct system dampers open filter install (clean) B.5 Temperature rise (Designed) Designed: F ( RASD C.5) Manufacturers range: F to F B.4 At Start -Up Fuel pressure crect Limit switch(s) operation crect Unit venting properly Circulation fan rotation crect Refrigerant pressures and levels crect Combustion efficiency test B.6 Temperature rise (Operating) F (SA temp. RA temp.) within manufacturers range This wk sheet has been designed to be generic in nature. Depending on the system being commissioned other infmation procedures may be required to ensure the safe and efficient operation of the system. Always consult and follow the equipment manufacturers installation instructions.

Commissioning (Part B-Fced Air Heating) (W 2b) B.7 External Static Pressure (Designed) B.8 External Static Pressure (Operating) a) ESP: in.w.c. ( RASD B.3) a) supply SP in. W.C (averaged) b) Filter PD: in.w.c. ( RASD C.6) b) return SP in. W.C (averaged) c) Coil PD: in.w.c. ( RASD C.7) c) ESP in. W.C. (a + b) d) Total PD: in.w.c. ( RASD C.8) Available press. in.w.c. (RASD C.9) d) Filter press. drop in. W.C. (averaged) e) Coil press. drop in. W.C. (averaged) (a d ) f) Total PD: in.w.c. (d + e) Available press. in.w.c. (c f ) B.9 System Air Flow (Temperature Rise method) a) Heating (from B.2) b) Operating temp. rise: F (from B.6) Estimated system air flow CFM a (b x 1.08) = CFM B.11 System Air Flow (velocity press. method) a) Supply air velocity pressure in.w.c. b) Return air velocity pressure in.w.c. System CFM = 4005 x VP x area = CFM 144 (area = duct cross sectional area in square inches) B.10 System Air Flow (ESP method) Operating ESP in. W.C. (From B.8 c) CFM @ closest ESP ( from manufacture blower data) CFM @ ESP CFM @ ESP Interpolated CFM at operating ESP CFM B.12 Conversion Fact f Operating CFM a) Design CFM CFM ( RASD B.4) b) Operating CFM CFM (B.9, B.10 B.11) c) Conversion fact (4 decimals) (a b) This wk sheet has been designed to be generic in nature. Depending on the system being commissioned other infmation procedures may be required to ensure the safe and efficient operation of the system. Always consult and follow the equipment manufacturer s installation instructions.

Commissioning (Part B-Fced Air Heating) (W 2c) B.13 Outlet Number S1 S2 S3 S4 S5 S6 S7 S8 B.14 Room Name B.15 Design CFM (RASD J.4) B.16 Crection Fact (B.12c) B.17 Crected CFM (B.15 x B.16) B.18 Measured CFM B.19 Branch size B.20 Diffuser size B.13 Outlet Number S9 S10 S11 S12 S13 S14 S15 S16 B.14 Room Name B.15 Design CFM (RASD J.4) B.16 Crection Fact (B.12c) B.17 Crected CFM (B.15 x B.16) B.18 Measured CFM B.19 Branch size B.20 Diffuser size B.13 Outlet Number S17 S18 S19 S20 S21 S22 S23 S24 B.14 Room Name B.15 Design CFM (RASD J.4) B.16 Crection Fact (B.12c) B.17 Crected CFM (B.15 x B.16) B.18 Measured CFM B.19 Branch size B.20 Diffuser size PART B FORCED AIR HEATING (return air flow verification): B.21 Inlet Number R1 R2 R3 R4 R5 R6 R7 R8 B.22 Room Name B.23 Design CFM (RASD H.4) B.24 Crection Fact (B.12c) B.25 Crected CFM (B.23 x B.24) B.26 Measured CFM B.27 Grille size

Commissioning (Part C-Hot Water Heating) (W 3a) C.1 Heating unit (Designed) C.2 Heating unit (Installed) make: make: fuel type: ng lp oil ele hp w other burner temp settings: on F off F circ. pump settings: on F off F heat anticipat setting manufacturer A system design operating water pressure psi fuel type: ng lp oil ele hp w other burner temp settings: on F off F circ. pump settings: on F off F heat anticipat setting A system operating water pressure psi C.3 Befe start-up electrical polarity crect unit electrically grounded fuel lines connected and tested drain lines connected and trapped all shipping bracing (packaging) removed expansion tank pressure crect water piping complete and tested all distribution system valves open water pressure regulat and relief valve set air purged from system drain (purge) hose connection capped C.4 Operating in steady state condition fuel pressure crect limit switch(s) operation verified unit venting properly circulation pump rotation crect water pressures crect operating supply water temperature limit minimum boiler temperature control set control system operating as designed system pressure when unit at high limit temperature is less than PRV setting C.5 System Water Flow (f use with Method B balancing only) a) Design water flow (from design wksheet) USGPM b) Reading from installed flow meter(s) USGPM Note: b must be equal to greater than a This wk sheet has been designed to be generic in nature. Depending on the system being commissioned other infmation procedures may be required to ensure the safe and efficient operation of the system. Always consult and follow the equipment manufacturer s installation instructions.

Commissioning (Part C-Hot Water Heating) (W 3b) System balancing using temperature drop (method A) C.6 Zone loop number 1 2 3 4 5 6 7 8 C.7 Room area served C.8 Inlet water temperature C.9 Outlet water temperature C.10 Temperature drop (C.8-C.9) C.6 Zone loop number 9 10 11 12 13 14 15 16 C.7 Room area served C.8 Inlet water temperature C.9 Outlet water temperature C.10 Temperature drop (C.8-C.9) Commissioning (Part C-Hot Water Heating) (W 3b) System balancing using flow meter (method B) C.11 Zone loop number 1 2 3 4 5 6 7 8 C.12 Room area served C.13 Designed flow rate C.14 rate C.11 Zone loop number 9 10 11 12 13 14 15 16 C.12 Room area served C.13 Designed flow rate C.14 rate

Commissioning (Part D-Fced Air Cooling) (W 4) D.1 Cooling unit (Designed) make: fan speed RPM: D.3 External Static Pressure (Designed) a) ESP: in.w.c. ( RASD B.3) D.2 Cooling unit (Installed) make: fan speed RPM: D.4 External static pressure (Operating) a) supply SP. in. W.C b) return SP in. W.C c) ESP (a + b) in. W.C. D.5 System air flow (ESP method) Operating ESP in. W.C. (From D.4 c) CFM @ closest ESP ( from manufacture blower data) CFM @ ESP CFM @ ESP Interpolated CFM at operating ESP CFM D.7 Airflow acceptability a) manufacturer minimum CFM/ton CFM b) tons of cooling ( output 12,000) tons c) minimum CFM ( a x b ) CFM d) Operating CFM CFM (D.5 D.6) d equal to greater than c D.6 System air flow (velocity press. method) a) Supply Air Velocity pressure in.w.c. b) Return Air Velocity pressure in.w.c. System CFM = 4005 x VP x area = CFM 144 This wk sheet has been designed to be generic in nature. Depending on the system being commissioned other infmation procedures may be required to ensure the safe and efficient operation of the system. Always consult and follow the equipment manufacturer s installation instructions.

Commissioning (Part E - BC/BC 9.32 Ventilation System) (W 5a) E.1 Principal Fan(s) (Designed) _1 NAFFVA (draft diverter) and 4 return intake E.2 Principal Fan(s) (Installed) _1 (with any NAFFVA max. air flow 110 CFM) NAFFVA (draft diverter) and 4 return intake Designed to: BCBC 9.32 /98 E.3 Kitchen/Bath Fans (Designed) _2 E.5 Make-up Air (designed) Passive duct size in. diameter 4 duct to return motized damper Powered Make-up Air # Make/Model Location CFM HVI Installed to: BCBC 9.32 /98 E.4 Kitchen/Bath Fans (Installed) _1 E.6 Make-up Air (designed) Passive duct size in. diameter 4 duct to return motized damper Powered Make-up Air # Make/Model Location CFM HVI E7. Distribution System Balancing f multi-branch systems (Supply / Exhaust) Supply S1 S2 S3 S4 S5 S6 S7 S8 S9 Room area Exhaust E1 E2 E3 E4 E5 E6 E7 E8 E9 Room area

Commissioning (Part E-NBC/OBC 9.32 Ventilation System) (W 5a) E.1 Principal Fan(s) (Designed) _1 HRV/ERV sensible recovery efficiency @ -13 F / 64+ CFM % Designed to: NBC 9.32 /95 OBC 9.32 /97 E.2 Principal Fan(s) (Installed) _1 HRV/ERV sensible recovery efficiency @ -13 F / 64+ CFM % Installed to: NBC 9.32 /95 OBC 9.32 /97 E.3 Supplemental Fans (Designed) _2 HRV/ERV sensible recovery efficiency @ -13 F / 64+ CFM % E.4 Supplemental Fans (Installed) _2 HRV/ERV sensible recovery efficiency @ -13 F / 64+ CFM % E.5 Principal Fan(s) Air Flow (Designed ) a) Total Ventilation Capacity CFM b) Minimum Principal Fan Air Flow CFM c) Maximum Principal Fan Air Flow CFM d) Designed Air Flow CFM E.7 Supplemental Fan(s) Air Flow (Designed ) a) Total Ventilation Capacity (E5a) CFM b) Principal Fan(s) air flow high (E6) CFM c) Minimum Supplemental Air Flow CFM E.6 Principal Fan(s) Air Flow (Installed ) High speed low speed Installed Air Flow CFM CFM low speed / single speed installed air flow is between minimum & maximum principal fan air flows (E5 b, E5 c) E.8 Supplemental Fan(s) Air Flow (Installed) Fan _2_ air flow (high speed) CFM Fan _3_ air flow (high speed) CFM Fan _4_ air flow (high speed) CFM Total Installed Air Flow is = E7 c E9. Distribution System Balancing f multi-branch systems (Supply / Exhaust) Supply S1 S2 S3 S4 S5 S6 S7 S8 S9 Room area Exhaust E1 E2 E3 E4 E5 E6 E7 E8 E9 Room area

Commissioning (Part E-CSA F326 Ventilation System) (W 5b) E.1 Fans/HRV/ERV (Designed) _1 2 sensible efficiency @ 32 F % watts @ -13 F % watts System designed to: NBC-6/95 OBC-6/97 CSA F326 /91 BCBC-6/98 E.3 Ventilation Air Flow (Designed ) a) Total Ventilation Capacity CFM (from Res. Mech. Ventilation Recd) b) Designed Air Flow HRV/ERV CFM Fan # CFM Fan # CFM Fan # CFM c) Total Ventilation Air Flow CFM E.2 Fans/HRV/ERV (Installed) _1 2 sensible efficiency @ 32 F % watts @ -13 F % watts System installed to: NBC-6/95 OBC-6/9 CSA F326 /91 BCBC-6/98 E.4 Ventilation Air Flow (Installed) High speed low speed HRV/ERV(balanced) CFM CFM Fan # CFM CFM Fan # CFM CFM Fan # CFM CFM Maximum air flow meets exceeds TVC Low(er) speed is 40% - 60% of TVC E5. Distribution System Balancing f multi-branch systems (Supply / Exhaust) Supply S1 S2 S3 S4 S5 S6 S7 S8 S9 Room area Exhaust E1 E2 E3 E4 E5 E6 E7 E8 E9 Room area

Commissioning (Part F-Depressurization) (W 6) F.1 Combustion equipment: (List combustion equip. & depressurization limits) 1. depressurization limit Pa 2. depressurization limit Pa 3. depressurization limit Pa 4. depressurization limit Pa 5. depressurization limit Pa F.3 Depressurization test instrument Make: Model: Test must be perfmed using an instrument capable of measuring 0 to 60 Pa with a sensitivity of 2 Pa. F.4 Depressurization test conditions Date of test: mm/dd/yy Test to be carried out at time of Final Inspection when house substantially complete. Wind Condition km/hr (maximum wind of 12 km/hr (9 mph) F.2 Exhaust equipment (List all exhaust equipment and relevant data) 1. CFM: on at TVCC on at CEC 2. CFM: on at TVCC on at CEC 3. CFM: on at TVCC on at CEC 4. CFM: on at TVCC on at CEC 5. CFM: on at TVCC on at CEC F.5 House depressurization measurements a) Starting (rest) pressure Pa b) Pressure at TVCC Pa c) Pressure at CEC Pa d) Ending (rest) pressure Pa Depressurization at TVCC Pa (greater of (b - a ) (b - d )) Depressurization at CEC Pa (greater of (c - a ) (c - d )) System confms to CSA F326 M91 Exhaust / Make-Up Fan Air Flows F.6 Fan HRV Dryer F.7 Room area F.8 Design exhaust F.8 Design make-up F.10 Measured exhaust F.11 Measured make-up Pa 1 2 3 4 5 10 25 50 75 100 150 In. W.C..004.008.012.016.02.04.1.2.3.4.6