MXD75 Multi Channel Suspended Solids and Turbidity Transmitter

Similar documents
Turbidity Systems. Inline Turbidity Measurements For More Visibility Into Your Process. INGOLD Leading Process Analytics

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

The Platinum Bullet - ORP. 546 In-Line Submersible. 547 Ball Valve Insertion Assembly. The Pressure Monster. Electrode & Tip Protection Options

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

CLARITY II TURBIDIMETER

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

Turbimax CUE21 / CUE22

OPTISENS TUR 2000 Technical Datasheet

Danfoss gas detection units

Bristol Babcock Oil Content Monitor "oil in water"

The supplier and installer of the system should be approved by the local civil defence authority.

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Features and Benefits

MEAS CAL ALARM WASH CONF APT4000 TC

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Features and Benefits

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible

Turbimax CUE21 / CUE22

P R O D U C T D ATA S H E E T

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

Analog Annunciator Unit SACO 16 A3. Product Guide

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Annunciator Unit SACO 16 D1. Product Guide

Danfoss gas detection unit Type GD Heavy Duty

Toroidal Conductivity Transmitters Series APT4000 Specifications

MAIN MENU/HOME SCREEN OVERVIEW

LC1350 Level Controller

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor

for Drinking Water Systems

APPLICATION DATA SHEET

Software Version 2.01 LEVEL MONITOR MODEL 220

Recalibrate the way you look at gas detection

Oil-in-Water Monitoring. for. Marine and Industrial. Applications

BC3250. Blowdown Controller

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

Portable central unit for several parameters

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Interface Modules for SENTRI

Dissolved Oxygen Measurement liquisys S COM 223 / 253

M7100 Pressure Transducer

Laser Level Measurement Products. Introducing the New LLT100

ProStar 325 UV-Vis Detector

Level gauges Series LS Level indicator, switch and transmitter for liquids

Sodium Monitor. Data Sheet SS/8036_5. Model Wide measuring range (0.01 gkg 1 to 10mgkg 1 ) covers all power station applications

Danfoss gas detection units

Annunciator unit. Application

P R O D U C T D ATA S H E E T

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

CIRRUS PRO. User Manual and Responsibilities ASPIRATING FIRE DETECTOR

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

Frequently asked questions: Intelligent Transmitter Series

SPECIFICATIONS - DETAILED PROVISIONS Section Magnetic Flowmeters C O N T E N T S

Inductive Conductivity

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

X56 Series Photometric Detectors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

Accuracy by Design Products for the HVAC Professional

Air Quality Sensors. Particle Matter, CO 2, Humidity, Temperature and Dust Products. OEM Sensor Components for Air Quality and Environmental Control

Certificate: _01 / 22 March 2013

D3 Wireless temperature alarm & monitoring system family. tek-troniks

SITRANS T temperature transmitters A broad product family for every application. sitrans

WIO200 Water In Oil measuring instrument

Controller Specification Sheet

Automation Technology for the Sugar Industry. ifm electronic -

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Speed and Frequency Seite 1 von 7

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

APPLICATION DATA SHEET

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

Reflective Optical Beam Smoke Detector User Guide

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

SmartAlarm Annunciator

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

Mobrey MCU900 Series Universal Control Unit

FDA241, FDA221 Siemens ASD

Analog Room Pressure Monitor RPC Series

APPLIED. OMA-406R Rackmount Process Analyzer

Beverage Processing System

IGD.CO.UK

Low Temperature Zirconia Oxygen Analyzer

MultiFix Central unit

Analog Input Module IC670ALG630

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Item Number Description Price. Accessories " Diesel/Water/Waste tank sender $ Battery temperature sensor $2.22

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

Installation, Operating and Maintenance Manual

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

High Pressure Conductivity Monitor

P R O D U C T D ATA S H E E T

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

OMA-300 Process Analyzer

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Complete packages with Software and Controller

SERIES 65 ENGINEERING PRODUCT GUIDE

Transcription:

~ Specialists in process suspended solids & turbidity ~ MXD75 Multi Channel Suspended Solids and Turbidity Transmitter Up to 3 Sensors on one Transmitter. Parameters include Suspended Solids, Turbidity and Electrodeless Conductivity. Multiple measurements can be selected and displayed. Simple menu driven interface. User selectable bar graph display option. SD card interface allows trouble free saving of configuration and simplifies software upgrades. Base model includes 2 relay and a single 4-20mA output. Can be expanded to 6 relay outputs and 6 isolated 4-20mA outputs. Simple 2 point or up to 9 point lineariser. Manual or automatic linearisation sample data input, making the process simple and fast. 8 independent programmable digital inputs with user selectable operations. Provides accurate, repeatable and reliable process monitoring of Suspended Solids and Turbidity using Quadbeam Technologies S10, S20, S40 or T30 sensors. Gain improved control in; Dairy Processing Food & Beverage Processing Waste Water Monitoring and Treatment Mining Pulp & Paper Industrial and Chemical MXD75 Multi Channel Suspended Solids and Turbidity Transmitter The MXD75 Transmitter is an innovative and sophisticated transmitter, yet still simple and intuitive to use. The clear LCD display providing up to 3 levels of information for up to 3 Sensors. 5 tactile feedback, micro-switched, silicone buttons help make interface simple and easy to use. With the capacity to include Electrodeless Conductivity sensors into the mix of analysis means it is possible to make significant efficiency improvements to processes like CIP. The relay and digital inputs allow for great flexibility coupled with the Cleaning function make sensor cleaning set-up simple. Quadbeam Technologies Ltd 17 Laureston Ave, Auckland, 2025, New Zealand ph+64-9-2764434 www.quadbeam.com info@quadbeam.com

SPECIFICATIONS* Measurement Input: A mix of up to 3 Sensors. Suspended Solids Series S10, S20, S40 and or Turbidity Series T30 and or. Electrodeless Conductivity Sensor ECS40. Current Output Up to 6 current outputs, depending on number of relays, each selectable 0-20mA or 4-20mA into 1000 ohms max, fully isolated to 2kV. Expandable up to 5% of any operating range and offset anywhere in that range. Setpoints and Control Relay 2 change over relays as standard, expandable up to a total of either 4 change over relays, or 4 change over relays plus 2 normally open relays. depending on the number of current outputs. Fully configurable setpoints with volt free contacts for each relay. Rated at 5A at 30V DC /5A at 250V AC Digital Inputs 8 contact closures for remote activation of user defined operations. Can be configured to operate either normally open or normally closed. SD Card Interface Display 95mm QVGA back lit LCD. Measurement Units: NTU, FTU, ppm, mg/l, g/l, %, EBC or OD can be selected and displayed. Calibration: Simple two point, or up to 9 point linearisations can be entered. Linearity: 0.1% of range. Repeatability: 0.1% of range. Ambient Operating Range: -20 C to +50 C MODEL NO. SELECTION GUIDE Basic Model No: MXD75 - Surface mounted enclosure to IP66. Output: I- 1 (max 3) fully isolated to 2kV current outputs, software selectable to be either 0 to 20mA or 4 to 20mA into a maximum of 1000 ohms. R- 2 relays (max 6) Supply Voltage: U - Universal 80-265V AC or DC, 15W max. LV - 18-36 V AC/DC or DC, 20W max. Sample model no: MXD75-2R-1I-U Surface mounted housing manufactured from moulded polyurethane and rated to IP66. Weight: Max 2.7kg EMC 2004/108/EC using BS EN 61326:2006 Low Voltage Directive 2006/95/EC using BS EN 61010-1:2001 * Due to our policy of continuous improvements, specifications are subject to change without notice. Quadbeam Technologies Ltd PO Box 22673 Auckland 1640 New Zealand Ph+64 (09) 276 4434 Email: info@quadbeam.com www.quadbeam.co.nz

T30 Turbidity Sensor Measurement range 0 to 50 through to 0 to 1000 FNU/FTU/NTU Turbidity Series 30 Sensors The T30 sensor is a new generation of Quadbeam process sensors, which combine both light attenuation and 90 degree scattered light measurements in a ratiometric sensor with digital communication. This technique vastly increases the sensitivity compared to sensors using just light attenuation. The T30 is designed to meet the international standards for turbidity measurement ISO 27027. The T30 sensor has two emitters and two detectors, set at exactly 90 degrees to each other. As each emitter is pulsed in sequence it produces two detector currents, one from the detector opposite the emitter (attenuation) and the other from the detector at 90 degrees to the emitter (scattered light). Signals from each detector are fed into the microprocessor which calculates the value of Turbidity from the ratio of the two emitter/detector pairs. Turbidity Series 30 Sensor A built in cleaner is standard with the immersion version of the T30. High pressure air with optional biocide is the recommended method of cleaning. The stainless steel support rods are designed to lift the sensor fingers above the floor of the drain and to protect the sensor fingers from impact. Monitoring of clarifier overflow weirs. Final outlet of effluent from DAF plants. Raw water inlet measurements in water treatment plants. Surface water monitoring. Solids loading in rivers and streams. Product breakthrough on plate heat exchangers. Percentage solids in fruit and vegetable juices. Hygienic Sensor Key Features Ratiometric signal processing compensates for changes in the optical properties of the emitters and detectors due to ageing and surface coating. Effects of colour, temperature and changes in background ambient light are virtually eliminated. The T30 sensor is designed for use with the Quadbeam MXD75 or MXD73 microprocessor based transmitter providing both relay and/or analogue outputs. www.quadbeam.com

SPECIFICATIONS* MODEL NO. SELECTION GUIDE Measuring Range 0 to 50 through to 0 to 1000 FNU / FTU / NTU (The measuring range will vary according to media and particle characteristics) Accuracy: +/-2% of reading Repeatability: +/-1% of reading Temperature: 0 to 80 C operating range Pressure: 10 Bar Polyurethane covered cable rated to 95 C. Extension cables can be supplied to extend the cable length up to a maximum of 50M. Body Style: T30-IMM - Immersion style body T30-3HY - Hygienic style body with 3" Triclover fitting Wavelength: 880nm - Standard. Other wavelengths available. Body Material: PP - Polypropylene 10 - Both immersion and hygienic sensors are supplied with a 10m cable as standard. Other lengths available. Connector: NC - No Connector. Cores stripped and crimped for direct connection to MSSD53 and MXD transmitters. CA - Amphenol Connector. For use with Hygienic sensors using extension cables. Sample model no: T30-IMM-880-PP-10-NC Optional Extras: Flanges/Adapters - To mount Immersion sensors into pipes or vessels, 50mm flanges or adapters for Triclamp, RJT and DIN11851 fittings are available. Hygienic Sensor * Due to our policy of continuous improvements, specifications are subject to change without notice. 07/04/13 Quadbeam Technologies Ltd 13/18 Lambie Drive, Manukau, Auckland, New Zealand PO Box 97511, Manukau, Auckland 2241, New Zealand ph+64-9-2764434 www.quadbeam.com info@quadbeam.co

S40 Suspendid Solid Sensor Measurement range 0 to 25 g/l in normal activated sludge, 0-1.5% Milk Fat s Immersion style sensors are designed for continuous on-line monitoring of suspended solids in industrial/municipal water and waste water treatment plants. Effluent monitoring in clarifier overflow weirs Raw water inlet turbidity measurements in water treatment plants Final effluent monitoring White water solids concentration Series 40 Suspendid Solids Sensors Hygienic Sensors Hygienic style sensors are designed for installation directly into food product lines where CIP cleaning is used. One piece polypropylene construction with a surface finish of better than Ra = 0.9μm eliminates bacteria traps. 3A Certified. Industry standard 3" Triclover connections. Product breakthrough on plate heat exchangers Solids content in whey Series 40 Sensors 'QuadBeam' optical systems use 2 pairs of infared light emitting diodes and photodetectors which are pulsed in sequence. Ratiometric signal processing compensates for changes in the optical properties of the emitters and detectors due to ageing and surface coating. Effects of colour, temperature and changes in background ambient light are virtually eliminated. Designed for use with the Quadbeam MXD microprocessor based transmitters providing both relay and/or analogue outputs. Physical dimensions and electrical characteristics are compatible with sensors from other suppliers allowing direct replacement. www.quadbeam.com

SPECIFICATIONS* Measuring Range 0 to 2.5g/l in normal activated sludge: Hygienic Sensor: 0 to 1.5% milkfat (The measuring range will vary according to media and particle characteristics) Accuracy: +/-2% of reading Repeatability: +/-1% of reading Temperature: 0 to 85 C operating range Pressure: 10 BarG Polyurethane covered cable rated to 95 C. Extension cables can be supplied to extend the cable length up to a maximum of 50M. MODEL NO. SELECTION GUIDE Body Style: S40-IMM - Immersion style body S40-3HY - Hygienic style body with 3" Triclover fitting Wavelength: 880nm - Standard. Other wavelengths available. Body Material: PP - Polypropylene 10 - Both immersion and hygienic sensors are supplied with a 10m cable as standard. Other lengths available. Connector: NC - No Connector. Cores stripped and crimped for direct connection to MXD transmitters. CA - Amphenol Connector. For use with Hygienic sensors using extension cables. Sample model no: S40-3HY-880-PP-10-NC Optional Extras: Cleaner - Powered using air at 10 Bar. Flanges/Adapters - To mount Immersion sensors into pipes or vessels, 50mm flanges or adapters for Triclamp, RJT and DIN11851 fittings are available. Hygienic Sensor * Due to our policy of continuous improvements, specifications are subject to change without notice. 07/04/13 Quadbeam Technologies Ltd 13/18 Lambie Drive, Manukau, Auckland, New Zealand PO Box 97511, Manukau, Auckland 2241, New Zealand ph+64-9-2764434 www.quadbeam.com info@quadbeam.co

s Immersion style sensors are designed for continuous on-line monitoring of suspended solids in waste water treatment plants. Mixed Liquor Suspended Solids (MLSS) Return Activated Sludge (RAS) Sludge Blanket Detection Product loss monitors in milk processing plants Series 20 Sensors ~ Specialists in process suspended solids & turbidity ~ Hygienic Sensors Hygienic style sensors are designed for installation directly into food product lines where CIP cleaning is used. One piece polypropylene construction with a surface finish of better than Ra = 0.9µm eliminates bacteria traps. 3A certified. Industry standard 3" Triclover connections. Extensively used in the dairy industry for milk fat measurements. Percentage solids in fruit & vegetable juices 'QuadBeam' optical systems use 2 pairs of infared light emitting diodes and photodetectors which are pulsed in sequence. Ratiometric signal processing compensates for changes in the optical properties of the emitters and detectors due to ageing and surface coating. Effects of colour, temperature and changes in background ambient light are virtually eliminated. Designed for use with the Quadbeam MSSD53 microprocessor based transmitters providing both relay and/or analogue outputs. Physical dimensions and electrical characteristics are compatible with sensors from other suppliers allowing direct replacement. Series 20 Suspended Solids Sensors PDS:S20PF1007

SPECIFICATIONS* Measuring Range : 0 to 10g/l in normal activated sludge Hygienic Sensor: 0 to 20% milkfat (The measuring range will vary according to media and particle characteristics) Accuracy: +/-2% of reading Repeatability: +/-1% of reading Temperature: o 0 to 85 C operating range Pressure: 10 BarG Polyurethane covered cable rated to o 95 C. Extension cables can be supplied to extend the cable length up to a maximum of 100M. MODEL NO. SELECTION GUIDE Body Style: S20-IMM - Immersion style body S20-3HY - Hygienic style body with 3" Triclover fitting Wavelength: 880nm - Standard. Other wavelengths available. Body Material: PP - Polypropylene 10 - Both immersion and hygienic sensors are supplied with a 10m cable as standard. Other lengths available. Connector: NC - No Connector. Cores stripped and crimped for direct connection to MSSD33/53 transmitters. CA - Amphenol Connector. For use with Hygienic sensors using extension cables. CS - Schaltbau Connector. For use with BTG/Zellweger Analytics transmitters. Sample model no: S20-IMM-880-PP-10-NC Optional Extras: Cleaner - Powered using air at 10 Bar. Flanges/Adapters - To mount Immersion sensors into pipes or vessels, 50mm flanges or adapters for Triclamp, RJT and DIN11851 fittings are available. Hygienic Sensor 114.0 55.0 110.0 43.0 1 1/4 Inch NPT 91.0 43.0 * Due to our policy of continuous improvements, specifications are subject to change without notice. Quadbeam Technologies Ltd PO Box 22673 Auckland 1640 New Zealand Ph/Fax +64 (09) 276 4434 Email: helpdesk@quadbeam.co.nz www.quadbeam.co.nz

s Immersion style sensors are designed for continuous on-line monitoring of suspended solids in waste water treatment plants, mining and refining operations. Return and waste sludge measurements Thickened and digested sludge to clarifiers Centrifugal, gravity or filter separation processes Series 10 Sensors ~ Specialists in process suspended solids & turbidity ~ Hygienic Sensors Hygienic style sensors are designed for installation directly into food product lines where CIP cleaning is used. One piece polypropylene construction with a surface finish of better than Ra = 0.9µm eliminates bacteria traps. 3A Certified. Industry standard 2 or 3" Triclover connections. Extensively used in the dairy industry for the determination of fat in milk Percentage solids in fruit juice 'QuadBeam' optical systems use 2 pairs of infared light emitting diodes and photodetectors which are pulsed in sequence. Ratiometric signal processing compensates for changes in the optical properties of the emitters and detectors due to ageing and surface coating. Effects of colour, temperature and changes in background ambient light are virtually eliminated. Designed for use with the Quadbeam MSSD53 microprocessor based transmitters providing both relay and/or analogue outputs. Physical dimensions and electrical characteristics are compatible with sensors from other suppliers allowing direct replacement. Series 10 Suspended Solids Sensors PDS:S10PF1007

SPECIFICATIONS* Measuring Range 0 to 25g/l in normal activated sludge 4% maximum of coal dust Hygienic Sensor: 0 to 40% milkfat (The measuring range will vary according to media and particle characteristics) Accuracy: +/-2% of reading Repeatability: +/-1% of reading Temperature: o 0 to 85 C operating range Pressure: 10 BarG Polyurethane covered cable rated to o 95 C. Extension cables can be supplied to extend the cable length up to a maximum of 100M. MODEL NO. SELECTION GUIDE Body Style: S10-IMM - Immersion style body S10-2HY - Hygienic style body with 2" Triclover fitting S10-3HY - Hygienic style body with 3" Triclover fitting Wavelength: 880nm - Standard. Other wavelengths available. Body Material: PP - Polypropylene 10 - Both immersion and hygienic sensors are supplied with a 10m cable as standard. Other lengths available. Connector: NC - No Connector. Cores stripped and crimped for direct connection to MSSD33/53 transmitters. CA - Amphenol Connector. For use with Hygienic sensors using extension cables. CS - Schaltbau Connector. For use with BTG/Zellweger Analytics transmitters. Sample model no: S10-3HY-880-PP-10-NC Optional Extras: Cleaner - Powered using air at 10 Bar. Flanges/Adapters - To mount Immersion sensors into pipes or vessels, 50mm flanges or adapters for Triclamp, RJT and DIN11851 fittings are available. Hygienic Sensor 114.0 110.0 55.0 43.0 1 1/4 Inch NPT 64.0 34.0 43.0 * Due to our policy of continuous improvements, specifications are subject to change without notice. Quadbeam Technologies Ltd PO Box 22673 Auckland 1640 New Zealand Ph/Fax +64 (09) 276 4434 Email: helpdesk@quadbeam.co.nz www.quadbeam.co.nz