Facility Explorer One-to-One Wireless Room Sensing System

Similar documents
WT-4000 Series Pneumatic-to-Direct Digital Control (DDC)

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page

NS Series Network Sensors

NS Series Network Sensors

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

WRS-TTx Series Wireless Room Temperature Sensors

Surface-Mounted NS Series Network Sensors without LCD

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

Vertical Wallbox-Mounted or Surface-Mounted NS Series Network Sensors with LCD

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers

TEC2100 Series Networked Thermostats

TEC3000 Series Stand-Alone and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers

NS Series Network Sensors

TEC210x-2 Series Networked Thermostats

T606MSx-4 and T606MSx-4+PIR Series Multi-Stage

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

TEC20x7-2 Series Wireless Thermostat Controllers with Two Outputs

Document # R01

P266 Series Single-Phase Condenser Fan Speed Control

TEC1100 Series Thermostats

1100D Wireless Receiver

S541.RF 4G Product Guide

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming.

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

E529 Smart Digital Thermostat Product Guide

1100X Wireless Receivers

Allure EC-Smart-Vue Sensor Series Line of communicating sensors with backlit display and graphical menus

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

Automatic Dimming Mirror with HomeLink

CD-Px Series Duct Mount CO 2 Transmitters

MR3CCUHV Temperature/Defrost Control

TM-3100 Series Room Temperature Sensor

F261 Series Fluid Flow Switches

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

DD15 Interface Module Product Guide

Panel XTO210/610/710 GPRS

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

1126 Series Ceiling Mount PIR Motion Detector

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

Pet Immune SAW PIR Motion Sensor

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide

Panel XT210/610/ Description. Supervised Wireless Technology

Description Supervised Wireless Technology PRODUCT SPECIFICATION SHEET

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

T125-E. Electric Fan Coil Thermostat. Product Bulletin. Operation. Appearance. Installation, Service and Maintenance

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

Embedded Door Sensor. User's Manual. Model SS881ZB. For other language versions, please visit:

Technical Application Guide

Quick start guide. SB3014-WM DECT 6.0 expansion wireless mic for use with AT&T model SB3014

Honeywell Temperature & Humidity Sensor with LCD

Installation and ZONES: Operation Manual. Model: ON STI-34108

CONTENTS. Installation Guide. VT7200 Series

PIR Occupancy & Motion Sensor

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

Digimax 210. Programmable Thermostat Compatible with Maxi Controller. User Guide

Installer Guide smart connect

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

Wireless Rain Gauge with Rainfall Memory and Digital Clock MODEL: RGR382

Wireless Driveway and Intruder Alert

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

powered by Note: This manual applies to several packages. As such, some parts and some steps may not pertain to the package that you purchased.

ACT2-CS Convenience Store Controller

1125 PIR Motion Detector

Digital Thermometer with Ice Alert and Clock

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

2 x screws. 2 x wall plugs

ET4 heat/cool day RF programmable room thermostat. ET4 Receiver

Q3200 Smart Home Alarm. Kit Content and Installation Guide

ShockLink. Important Product Information.

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

180 Degree Ceiling Mounted Occupancy Sensors

WS-9117U-IT Wireless 915 MHz Temperature Station. Instruction Manual

field SENSE EC-FS2-001-A

WT-4000 Series Pneumatic-to-Direct Digital Control (DDC) Room Thermostats

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

Q3000 Smart Home Alarm. Kit Content and Installation Guide

DeLaval activity meter system Instruction Book

HomeLink Wireless Control System

PRODUCT DIAGRAM PACKAGE CONTENTS

Architectural and Engineering Specification for a. Flash / Flare

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers

EasyAir SNH200. Sensors. Datasheet. EasyAir SNH200

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Light Level Detector, Surface Mount 5754PE. Installation Instructions

TruPortal Wireless Locks Quick Reference

Thermometer model 02059

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

Optima ZigBee Thermostat

VT8300 Series Installation Guide 24 Vac Low Voltage

Rev D 3/20/17

Product Manual. TZ Analog Sensors. TZ Sensors 8115CF 8116CF 8117CF 8118CF. Date: January 2015 Document Number: _B

Johnson Controls Fan Coil Units and Direct Digital Controls

Document # R00

TEC BACnet MS/TP Networked Thermostat Controller with Single Proportional Output and One-Speed Fan Control

K100A Insertion Probe Thermometer

Wireless Plug Load Control

L. Terminal block Connecting Label:

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

Transcription:

Facility Explorer One-to-One Wireless Room Sensing System Product Bulletin FX-WRZ7860-0 The Facility Explorer One-to-One Wireless Room Sensing System enables RF room sensors to wirelessly communicate to FX-PC Series s (FX-PCA, FX-PCG, and FX-PCV). This One-to-One Wireless Room Sensing System is the functional equivalent of an NS Series Network Sensor, but it eliminates all the hard wiring between the room sensor and the controller. The two main components of this system are the FX-WRZ Series Wireless Room Sensor and the FX-WRZ7860-0 Receiver. Depending on the model, the FX-WRZ Series Sensor can transmit sensed temperature, temperature setpoint, sensed humidity, occupancy status, and low battery conditions. FX-WRZ Series Wireless Room Sensor models are available with or without an LCD, and are designed for indoor intra-building applications only. Code No. LIT-12011664 Issued October 25, 2013 Supersedes June 5, 2012 Refer to the QuickLIT website for the most up-to-date version of this document. Several models of FX-WRZ Series Wireless Room Sensors include an onboard passive infrared (PIR) occupancy sensor that detects motion to determine if a space is occupied. This feature maximizes up to 30% energy savings in high-energy usage environments such as schools, dormitories, offices, and hospitals by adjusting the temperature of the space based on the occupancy status. In addition, the PIR occupancy sensor facilitates trending of floor space usage in these environments. The FX-WRZ7860-0 Receiver acts as an interface between the FX-WRZ Series Wireless Room Sensors and the FX-PC Series. The FX-WRZ7860-0 receives the data from the FX-WRZ Series Wireless Sensors, and passes it onto the FX-PC Series over its Sensor Actuator (SA) Bus. Figure 1: Facility Explorer One-to-One Wireless Room Sensing System In a typical application, one FX-WRZ Series Wireless Room Sensor reports to one FX-WRZ7860-0 Receiver; however, you can associate up to five FX-WRZ Series Wireless Room Sensors with a single FX-WRZ7860-0 Receiver. In these multi-sensor applications, the receiver passes all of the room sensors data to the FX-PC Series. You can then configure the FX-PC Series to either average the room sensors temperature and humidity inputs, or select the highest or lowest sensed temperature and humidity for control of the target zone. Table 1: Features and Benefits (Part 1 of 2) Features Benefits One-to-One Wireless RF Design Enables quick, economical, and low-maintenance installations, which reduce installation and wiring costs. Stylish, Lightweight Wireless Room Sensors with Occupancy Override Button 60-Second Transmission Intervals Make installation simple and provide room temperature, humidity, setpoint temperature, occupancy status, and low battery conditions to FX-PC Series s (FX-PCA, FX-PCG, and FX-PCV). Greatly extend sensor battery life, and enable continuous operation over the life of the batteries (approximately 4 to 5 years) while maintaining an even temperature in the controlled zones. Facility Explorer One-to-One Wireless Room Sensing System Product Bulletin 1

Table 1: Features and Benefits (Part 2 of 2) Benefits Features Built-in Integral Wireless Signal Strength Testing Multiple Sensor Temperature Averaging and High/Low Selection Onboard PIR Occupancy Sensor Available on Some Wireless Room Sensors Compact, Easily Installed Receiver Simple DIP Switch Settings Optional, Battery-Powered Wireless Sensing System Tool High Resistance to RF Interference from Other Radio Devices or RF Noise Sources Optional Repeater Blinking LED Light to Indicate Firmware Version Provides quick, easy, visual indication of the wireless RF signal strength between a sensor and associated receiver, helps locate optimum device positions during installation, and aids in troubleshooting. Enhance zone temperature control by enabling up to five sensors to report to a single receiver, which allows the controller to average the sensor temperature or select the highest or lowest temperature value to control the zone. Maximizes up to 30% energy savings in high-energy usage environments, and facilitates trending floor space. Receives sensed temperature, humidity, setpoint, and low-battery condition from an FX-WRZ Series Wireless Room Sensor, and interfaces directly with an FX-PC Series. Provide easy commissioning and up to 4,096 unique receiver addresses. Provides wireless mobility to check for best RF link and determine optimum receiver mounting locations. Results from application-based frequency agility, which allows for automatically changing to a different channel to avoid RF interference and missed messages. Extends the operating range between a sensor and a receiver. Five seconds after the power is applied, the red LED flashes to indicate the firmware revision. For example, firmware revision 3 is indicated by the LED flashing three times during the startup process. Application In a typical application, the FX-WRZ7860-0 Receiver forwards (by means of the SA Bus) zone data sent by an FX-WRZ Series Wireless Room Sensor to any one of several FX-PC Series s. As an example, in a VAV application, the FX-WRZ Series Wireless Room Sensor sends zone conditions to the FX-WRZ7860-0 Receiver, which passes that data to an FX-PC Series Programmable VAV Controller. IMPORTANT: Use the Facility Explorer One-to-One Wireless Room Sensing System only to provide an input to equipment under normal operating conditions. Where failure or malfunction of the room sensor or receiver could lead to personal injury or property damage to the controlled equipment or other property, additional precautions must be designed into the control system. Incorporate and maintain other devices, such as supervisory or alarm systems or safety or limit controls, intended to warn of or protect against, failure or malfunction of the room sensor or receiver. IMPORTANT: The Facility Explorer One-to-One Wireless Room Sensing System is not designed or intended for use in mission-critical or life/safety applications. Operation The Facility Explorer One-to-One Wireless Room Sensing System comprises one or more FX-WRZ Series Wireless Room Sensors and an FX-WRZ7860-0 Receiver that receives wireless RF data from the sensor, and provides zone control data to specified FX-PC Series s in building HVAC systems. The FX-WRZ Series Wireless Room Sensor and FX-WRZ7860-0 Receiver combination is functionally equivalent to a network sensor, such as an NS-BTP7001-0, minus the communication wiring typically located inside the wall. Like a network sensor, the FX-WRZ7860-0 Receiver is designed to communicate over an SA Bus interface via BACnet Master-Slave/Token-Passing (MS/TP) protocol with FX-PC Series s. The receiver supplies the sensed zone temperature, humidity, temperature setpoint, and occupancy override data. The FX-WRZ7860-0 Receiver uses direct-sequence, spread-spectrum RF technology and operates on the 2.4 GHz industrial, scientific, and medical (ISM) band. The receiver meets the IEEE 802.15.4 standard for low power, low duty-cycle RF transmitting systems. An FX-WRZ7860-0 Receiver operates as a transceiver to create a bidirectional association with an FX-WRZ Series Wireless Room Sensor. 2 Facility Explorer One-to-One Wireless Room Sensing System Product Bulletin

RFStatus LEDs For installations where the RF signal path between the sensor and receiver provides unsatisfactory results, locate an FX-ZFR1811, which serves as a repeater, between the sensor and the receiver. Refer to the Facility Explorer One-to-One Wireless Room Temperature Sensing System Technical Bulletin (LIT-12011663) for information on commissioning the FX-WRZ7860-0 Receiver and configuring One-to-One Wireless Room Sensing Systems. Dimensions See Figure 2 for FX-WRZ7860-0 Receiver physical features and dimensions. See Figure 3 for FX-WRZ Series Wireless Room Sensor physical features and dimensions. Tamper Resistant Set Screw SA 3-5/32 (80) Back of Base to Front of Dome 1-1/2 (38) 3-5/32 (80) RJ-12 Port for SA Bus Connection (on Underside) Figure 2: FX-WRZ7860-0 Receiver Physical Features and Dimensions, in. (mm) FIG:wrz_7860_dmnsns LCD (FX-WRZMTB01-0, FX-WRZTHB00-0, FX-WRZTTB00-0, FX-WRZTTD00-0 Manual Occupancy Override Button Battery Level and Signal Strength LED (Non-LCD, or Temperature Button F/ C (LCD PIR Occupancy Sensor (FX-WRZMxN01-0 FX-WRZMTx01-0 Back of Base to Front of Setpoint Control Dial 1-1/2 (38) 3-5/32 (80) Tamper Resistant Set Screw 4-23/32 (120) Temperature Setpoint Control Dial Figure 3: FX-WRZ Series Wireless Room Sensor Physical Features and Dimensions, in. (mm) FIG:wrz_mtb_frnt Facility Explorer One-to-One Wireless Room Sensing System Product Bulletin 3

Ordering Information Use Table 2 to order components of the Facility Explorer One-to-One Wireless Room Sensing System. Use Table 4 to order accessories. Repair Information If the Facility Explorer One-to-One Wireless Room Sensing System fails to operate within its specifications, replace the affected components. For replacement components, contact the nearest Johnson Controls representative. Table 2: Ordering Information Product Code Number Description FX-WRZ7860-0 One-to-One Wireless Receiver FX-WRZMHN01-0 Wireless Room Temperature and Humidity Sensor with PIR Occupancy Sensor, Battery Level/Signal Strength LED, and Manual Occupancy Override Button FX-WRZMNN01-0 Wireless Room Sensor (No Temperature or Humidity Sensing) with PIR Occupancy Sensor, Battery Level/Signal Strength LED, and Manual Occupancy Override Button FX-WRZMTB01-0 Wireless Room Temperature Sensor with PIR Occupancy Sensor, Display, Setpoint Adjustment Scale: 55 to 80 F (13 to 27 C), F/C Button, and Manual Occupancy Override Button FX-WRZMTN01-0 Wireless Room Temperature Sensor with PIR Occupancy Sensor, Battery Level/Signal Strength LED, and Manual Occupancy Override Button FX-WRZTHB00-0 Wireless Room Temperature and Humidity Sensor with Display, Warmer/Cooler (+/-) Setpoint Adjustment or Setpoint Adjustment Scale: 55 to 85 F (13 to 27 C), F/C Button, RH Button, and Manual Occupancy Override Button FX-WRZTHN00-0 Wireless Room Temperature and Humidity Sensor with Battery Level/Signal Strength LED and Manual Occupancy Override Button FX-WRZTHP00-0 Wireless Room Temperature and Humidity Sensor with Warmer/Cooler (+/-) Setpoint Adjustment and Manual Occupancy Override Button FX-WRZTTB00-0 Wireless Room Temperature Sensor with Display, F/C Button, and Manual Occupancy Override Button FX-WRZTTD00-0 Wireless Room Temperature Sensor with Display, F/C Button, Fan Speed Control, and Manual Occupancy Override Button FX-WRZTTP00-0 Wireless Room Temperature Sensor with Warmer/Cooler (+/-) Setpoint Adjustment, Battery Level/Signal Strength LED, and Manual Occupancy Override Button FX-WRZTTR00-0 Wireless Room Temperature Sensor with Battery Level/Signal Strength LED, Manual Occupancy Override Button, and No Setpoint Adjustment FX-WRZTTS00-0 Wireless Room Temperature Sensor with Setpoint Adjustment Scale: 55 to 80 F (13 to 27 C), Battery Level/Signal Strength LED, and Manual Occupancy Override Button 4 Facility Explorer One-to-One Wireless Room Sensing System Product Bulletin

Table 3: FX-WRZ Series Sensor Model Comparison Sensor Model Temperature 3% Humidity Display F/C Button Fan Control Occupancy Override Button PIR Occupancy Sensor Setpoint Adjustment Dial 1 FX-WRZMHN01-0 x x x x NO DIAL FX-WRZMNN01-0 x x NO DIAL FX-WRZMTB01-0 x x x x x CONFIG FX-WRZMTN01-0 x x x NO DIAL FX-WRZTHB00-0 x x x x x CONFIG FX-WRZTHN00-0 x x x NO DIAL FX-WRZTHP00-0 x x x W/C FX-WRZTTB00-0 x x x x CONFIG FX-WRZTTD00-0 x x x x x CONFIG FX-WRZTTP00-0 x x W/C FX-WRZTTR00-0 x x NO DIAL FX-WRZTTS00-0 x x SCALED 1. Warmer/cooler temperature offset (W/C), single-value in 55 to 85 F (13 to 29 C) range (SCALED), system-configured - available on display models only (CONFIG), no setpoint dial (NO DIAL) Table 4: Accessories Product Code Description Number T-4000-119 FX-WRZSST-120 CBL-NETWORK6-0 CBL-NETWORK25 CBL-NETWORK50 CBL-NETWORK75 CBL-NETWORK100 FX-ZFR1811-0 FX-ZFRRPT-0 Allen-Head Adjustment Tool: 1/16 in. (1.6 mm), 30 Tools per Bag Wireless Sensing System Tool: For Use with an FX-WRZ Series Sensor to Function as a Site Survey Tool for the FX-WRZ7860-0 One-to-One Room Temperature Sensing System or for the FX-ZFR1800 Series Wireless Field Bus System 6 ft (1.8 m) SA Bus Interface Cable to Connect FX-WRZ7860-0 Receiver to FX-PC Series 25 ft (7.6 m) SA Bus Interface Cable to Connect FX-WRZ7860-0 Receiver to FX-PC Series 50 ft (15.2 m) SA Bus Interface Cable to Connect FX-WRZ7860-0 Receiver to FX-PC Series 75 ft (22.9 m) SA Bus Interface Cable to Connect FX-WRZ7860-0 Receiver to FX-PC Series 100 ft (30.5 m) SA Bus Interface Cable to Connect FX-WRZ7860-0 Receiver to FX-PC Series Wireless Field Bus Router Power Supply for Optional FX-ZFR1811-0 Wireless Field Bus Router Facility Explorer One-to-One Wireless Room Sensing System Product Bulletin 5

Technical Specifications FX-WRZ7860-0 Receiver for One-to-One Wireless Room Sensing Systems Interface Supply Voltage Current Consumption Addressing Ambient Limits RF Band Transmission Power Transmission Range Transmissions Receiver Outputs Temperature Sensor Accuracy Temperature Sensor Type Humidity Measurement Range Humidity Sensor Accuracy Humidity Sensor Type PIR Occupancy Sensor Motion Detector Materials Compliance Shipping Weight Power and SA Bus Interface between FX-WRZ7860-0 Receiver and FX-PC Series Nominal 15 VDC via the SA Bus; 6.7 to 16.5 VDC Required 10 ma Maximum DIP Switches, Field Adjustable for up to 4,096 Unique RF Addresses Operating: 32 to 122 F (0 to 50 C), 5 to 95% RH, Noncondensing Storage: -40 to 160 F (-40 to 71 C), 5 to 90% RH, Noncondensing Direct-Sequence, Spread-Spectrum, 2.4 GHz ISM Bands 10 mw Maximum 150 ft (45 m) Maximum Indoor Line of Sight; 100 ft (30 m) Practical Average Indoor Every 60 Seconds (±10 Seconds) One RJ-12 Port for SA Communication Bus Output (Sensed Zone Temperature and Humidity, Temperature Setpoint, and Occupancy Override Data) FX-WRZ Series Wireless Room Sensors (Temperature Only Models, and Temperature and Humidity : 1.0F (0.6C ) over the Range of 55 to 85 F (13 to 29 C); 1.5F (0.9C ) over the Range of 32 to 55 F (0 to 13 C) and 85 to 110 F (29 to 43 C) FX-WRZ Series Wireless Room Sensors (Temperature Only Models, and Temperature and Humidity : Internal 10k ohm Negative Temperature Coefficient (NTC) Thermistor FX-WRZ Series Wireless Room Sensors (Temperature and Humidity : Full Range 0 to 100% RH; Calibrated Range 10 to 90% RH at 73 F (23 C) FX-WRZ Series Wireless Room Sensors (Temperature and Humidity : ±3% RH across the Range of 20% to 80% RH, ±6% RH across the Range of 10% to 20% RH and 80% to 90% RH within a Temperature Range of 55 to 85 F (13 to 29 C) FX-WRZ Series Wireless Room Sensors (Temperature and Humidity : Planar Capacitive Polymer Sensor FX-WRZ Series Wireless Room Sensors (PIR Occupancy Sensor : Minimum 94 Angular Degrees up to a Distance of 15 ft (4.6 m) Based on a Clear Line of Sight NEMA 1 White Plastic Housing; UL94-5VB and V-0 Plenum Flammability Rated United States: Transmission Complies with FCC Part 15.247 Regulations for Low Power Unlicensed Transmitters Transmitter FCC Identification: TBF-MATRIXL or OEJ-WRZRADIO Canada: Industry Canada IC:5969A-MATRIXL or 279A-WRZRADIO Europe: CE Mark Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the R&TTE Directive 1999/05/EC. Japan: Transmission Complies with Article 38-24 Paragraph 1 of the Radio Law Certification Number: ATCB012834 Australia and New Zealand: Australia/NZ Emissions Compliant (C-Tick Mark) 0.2 lb (0.09 kg) 6 Facility Explorer One-to-One Wireless Room Sensing System Product Bulletin

FX-WRZ Series Wireless Room Sensors Power Requirements Addressing Ambient Conditions Wireless Band Transmission Power Transmission Range Transmissions Temperature System Accuracy (Temperature Only Models, and Temperature and Humidity Temperature Sensor Type (Temperature Only Models, and Temperature and Humidity Humidity Calibrated Range (Temperature and Humidity Humidity Accuracy (Temperature and Humidity PIR Occupancy Sensor Motion Detection (Models with PIR Occupancy Sensor) Materials Mounting Compliance Shipping Weight 3 VDC Supplied by Two 1.5 VDC AA Alkaline Batteries (Included with Sensor); Typical Battery Life: 48 Months (36 Months Minimum) DIP Switches; Field Adjustable MS/TP Address, Network Number, and Zone Address Operating: 32 to 122 F (0 to 50 C), 5 to 95% RH, Noncondensing Storage: -40 to 160 F (-40 to 71 C), 5 to 95% RH, Noncondensing Direct-Sequence, Spread-Spectrum, 2.4 GHz ISM Band 10 mw Maximum 100 ft (30 m) Maximum Line of Sight; 50 ft (15 m) Recommended Temperature: Every 60 Seconds (±20 Seconds) Humidity: Every 3 Minutes, or 1 Minute Intervals if Temperature or Humidity Changes 1.0F 0.6C Over a Range of 55 to 85 F (13 to 29 C); 1.5F 0.9C Over a Range of 32 to 55 F (0 to 13 C) and 85 to 110 F (29 to 43 C) Internal 10k ohm Negative Temperature Coefficient (NTC) Thermistor 10% to 90% RH at 73 F (23 C) ±3% RH across the Range of 20% to 80% RH, ±6% RH across the Range of 10% to 20% RH and 80% to 90% RH within a Temperature Range of 55 to 85 F (13 to 29 C) Minimum 94 Angular Degrees up to a Distance of 15 ft (4.6 m) Based on a Clear Line of Sight NEMA 1 White Plastic Housing Screw Mount or Double-Sided Adhesive Foam Tape Mount; Double-Sided Adhesive Foam Tape Included United States: Transmission Complies with FCC Part 15.247 Regulations for Low Power Unlicensed Transmitters Transmitter FCC Identification: TFB-MATRIXL or OEJ-WRZRADIO Canada: Industry Canada IC: 5969A-MATRIXL or 279A-WRZRADIO Europe: CE Mark Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the R&TTE Directive 1999/05/EC. Japan: Transmission Complies with Article 38-24 Paragraph 1 of the Radio Law Certification Number: ATCB012834 Australia and New Zealand: C-Tick Mark, Australia/NZ Emissions Compliant 0.3 lb (0.14 kg) The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. Facility Explorer One-to-One Wireless Room Sensing System Product Bulletin 7

United States Emissions Compliance Compliance Statement (Part 15.19) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Warning (Part 15.21) Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. Canadian Emissions Compliance Industry Canada Statement The term IC before the certification/registration number only signifies that the Industry Canada technical specifications were met. Le terme «IC» précédant le numéro d'accréditation/inscription signifie simplement que le produit est conforme aux spécifications techniques d'industry Canada. Building Efficiency 507 E. Michigan Street, Milwaukee, WI 53202 Johnson Controls is a registered trademark of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 2013 Johnson Controls, Inc. 8 Facility Explorer One-to-One Wireless Room Sensing System Product Bulletin Published in U.S.A. www.johnsoncontrols.com