Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

Similar documents
PTE0705 Electric Fence Monitor

Ethernet General Purpose

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

General Purpose IO Technical Manual

USER MANUAL FOR OPERATING SYSTEM

ZM20 OEM Technical Manual

ZLM4 OEM Technical Manual

Carbon Monoxide Transmitter

How to use the BTRM in Remote Enclosures

Added password for IP setup page : Password must be in IP format!

ZM1 User Manual JVA TECHNOLOGIES.

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Beacon 110 Gas Monitor Operator s Manual

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

ANALOX 3000 Carbon Monoxide Monitor

Analog Room Pressure Monitor RPC Series

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Ax60+ Multi-Gas. Service Manual

Installation Manual Tracker 221

MTRA-FSP Level Control Relay. Installation & Operation Manual

ELECTRO-FENCE TM. Fence Protection System. Installation Manual. EF_Install_V2

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Frequently asked questions: Intelligent Transmitter Series

Duct and Rough Service Carbon Monoxide Sensor

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

Beacon 800 Gas Monitor Operator s Manual

20 Light Remote Annunciator

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Dryer Controller M720

Door Release Power Supply

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

products and services

Pioneer-R16 Gas Monitor Operator s Manual

SEC 2000 Millenium Infrared Gas Detector

C-Bus Four Channel Analogue Output Unit Installation Instructions

User Manual. Dryer Controller M720

P2267 NETWORK INTERFACE

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Installation, Operating and Maintenance Manual

Universal Gas Detector

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

C-Bus Four Channel General Input Unit Installation Instructions

Application, Installation, Operation & Maintenance Manual

OVEN INDUSTRIES, INC.

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

OPERATION AND INSTALLATION MANUAL

BX444-Mc Gas Detector

PLW PLW TOP LOAD. PV Hot Water Controller. PV Solar Hot Water Controller PLASMATRONICS. Manual. Read this before installing. Rev. U3.

Version 1.03 January-2002 USER S MANUAL

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

Beacon 410A Gas Monitor Operator s Manual

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Pump-Down Controller MODEL 4052

Superdew 3. Hygrometer. Operating Instructions

21-light Remote Annunciator. Owner s Manual

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Intelligent Security & Fire Ltd

Fratech Multipath-IP

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Public Safety DAS Annunciator Panel

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Danfoss gas detection units

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

10yr O2NE & Safe-Ox. User Manual

Model 4001 Series Single Channel Controller

Memcom Emergency Telephone

FIRERAY 5000 range USER GUIDE

Pump-Up Controller MODEL 4062

T4000 Security Communicator

NESS 5000 SERIES DIALLER

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

Constant voltage 3-phase rectifier.

Series Temperature Controller Instruction Sheet

CLEANROOM MONITOR CR3A Network - Installation Instructions

Intelligent addressable fire alarm control panel

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

WALLACE & TIERNAN CONTROLLERS & ANALYSERS CHEMTRIM DISINFECTION CONTROLLER PRODUCT SHEET

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

Series Digital Controller Instruction Sheet

Modbus TCP/IP Option Instruction Manual

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

PARTICULATE EMISSION MONITORING

M2 Rig Monitor Operator s Manual

WIO 200B and WIOI200B Water in oil sensor

OWNER S OPERATION MANUAL

EZY SWITCH. SMS-IRR-4 System Monitor Installation Manual

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

DMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual

Danfoss gas detection unit Type GD Heavy Duty

CU 300. Installation and operating instructions GRUNDFOS INSTRUCTIONS

Transcription:

Remote Monitor PTE0700 SECURITY ELECTRONICS User Manual PTE0700 V2 Series Remote Monitor Pakton Technologies Pty Ltd ABN 66 405 694 842 16 Ferrier Road, Narangba Qld 4504 PO Box 408, Narangba QLD 4504 Tel: (07) 3888 3793 Fax: (07) 3888 4330 Email: sales@pakton.com.au www.pakton.com.au

1.0 Table of Contents 1.0 TABLE OF CONTENTS...2 2.0 LIST OF TABLES...3 3.0 LIST OF FIGURES...4 4.0 DESCRIPTION...5 5.0 FEATURES...6 Explanation of some terms used in this section...7 6.0 SPECIFICATIONS...9 7.0 INSTALLATION...10 Hardware installation...10 Output Connections...10 Stand Alone Operation...11 Alarm Panel Operation...11 Solar Panel Operation...12 Low Fence Voltage Set Point Calibration Automatic set point...12 Low Fence Voltage Set Point Calibration Manual set point...12 Delay Calibration automatic and manual low fence voltage alarm set point....13 8.0 ELECTRIC FENCE MONITOR OUTPUTS...14 LED Visual Display...14 Relay Output...14 0-5V Analog Output...15 4-20mA Analog Output...15 RS232 Output...15 Optional Display Board...17 9.0 WARRANTY...18 14/02/07 Page 2 of 18

2.0 List of Tables Table 1 Model Features...6 Table 2 Specifications...9 Table 3 Relay Connections...14 Table 4 PTE0700 RS232 Connections...15 14/02/07 Page 3 of 18

3.0 List of Figures Figure 1 - Output Terminal Locations...10 Figure 2 - Stand Alone Operation...11 Figure 3 - Alarm Panel Operation...11 Figure 4 Solar Panel Operation...12 Figure 5 PAE036 LCD Expansion PCB...17 14/02/07 Page 4 of 18

4.0 Description The PTE0700 Electric Fence Monitor Series are low cost electric fence monitors designed primarily for remote monitoring applications. While monitoring an electric fence for low voltage conditions, they also enable system designers to include electric fence voltages as inputs into remote telemetry or SCADA systems. This series consists of four models, the PTE0700, 701, 702 and 703. The features of the various models can be found in the Features section of this document. The PTE0700 series can also be customised to meet your own requirements for quantity purchases. Suitable Applications for the PTE0700 Series Rural - pastoral stations Security fences Vermin control fences Zoo and sanctuary enclosures 14/02/07 Page 5 of 18

5.0 Features The various models within this range have the following features. Inputs / Outputs Directly connects to 10kV electric fence with high voltage inputs Shows working fence with Green Pulse LED Shows failing fence with Red Low Voltage LED Alarms failing fence with internal beeper Alarms failing fence by setting a relay Alarms failing fence by setting a failsafe relay Current output 4-20mA proportional to 0-10kV input. Voltage output 0-5V proportional to 0-10kV input. Simple RS-232 Data Output SCADA friendly RS-232 Data Output PTE0700 PTE0701 PTE0702 PTE0703 Hardware IP65 weather proof wall mountable enclosure 12V DC Powered Adjustment Low Fence Voltage alarm set point or automatic selfsetting Adjustable delay from Low Fence Voltage to firing alarm Other Features Very low current consumption 10kV Opto-Isolation from fence inputs Expansion socket for optional LCD Display Connects directly to 12V/2W solar panel to charge battery. Table 1 Model Features 14/02/07 Page 6 of 18

Explanation of some terms used in this section Low Fence Voltage Alarm set point is the fence voltage above which the Electric Fence Monitor will show a working fence and below which the Electric Fence Monitor will show a failing fence. The PTE0700 series Electric Fence Monitors allow you to manually adjust this set point, or alternatively they can be set to automatically adjust this set point. When automatically adjusting, it also follows the fence s performance. If, for example, the fence were operating at 7kV when the Electric Fence Monitor is switched on, it would set its Low Fence Voltage Alarm set point at about 6kV. As days go by, grass might build up on the electric fence, lowering the voltage on the fence, or a dry spell might slowly increase the voltage on the fence. The Electric Fence Monitor sees the gradual change and adjusts its set point accordingly. If, however, the fence voltage drops more quickly the Electric Fence Monitor will raise an alarm. False alarms are less likely to be raised if the Electric Fence Monitor is allowed to automatically adjust its set point. Another advantage of using auto-adjustment is that the Monitor will also alarm on a quickly rising voltage. Adjustable Delay from Low Fence Voltage to firing alarm is the adjustable amount of time the Electric Fence Monitor waits after the fence fails before it raises an alarm. For example, If the delay is set to six seconds, and the fence voltage goes low for only three seconds, no alarm is raised. The alarm would only be raised if the fence voltage stayed below the Low Fence Voltage Alarm set point for more than six seconds. Alarms failing fence with internal beeper means that a small siren contained within the Electric Fence Monitor will sound when the fence voltage goes below the Low Fence Voltage Alarm Set Point. Alarms failing fence by setting relay there is one relay inside the Electric Fence Monitor, with three terminals, discussed fully in Section 0.0 Relay Output below. 12vDC powered means that the Electric Fence Monitor is powered by any nominal twelve-volt supply such as a mains plug pack or battery. 10kV opto isolation from fence inputs means that the fence inputs are not electrically connected to the rest of the circuitry. Instead, they are connected optically. This means that all accessories connected to the Electric Fence Monitor and the Electric Fence Monitor itself are protected from excessive voltages on the fence. Current output 4-20mA proportional to 0-10kV input means that the Electric Fence Monitor can supply an industry standard analogue signal to other equipment such as SCADA or Telemetry RTU. 14/02/07 Page 7 of 18

Voltage output 0-5V proportional to 0-10kV input as above for voltage analogue inputs. RS232 output means that the data collected by the Electric Fence Monitor can be transmitted to other equipment in RS232 format. The serial port found on most computers uses the RS232 format. You can easily use a computer to collect, save and display this information. 14/02/07 Page 8 of 18

6.0 Specifications Specification Name Supply voltage Supply current Solar Panel (optional) Min measurable input voltage Input voltage measurement Relay output Energiser compatibility Max 4-20mA loop excitation voltage Accuracy Drift Temperature range 10-18V DC 6mA (20mA with relay on) Specification 12V/2W (use with 12V lead acid battery) 0.3 kv Peak to peak Dry changeover contacts 30V 1A (<500mA recommended) Compatible with Low impedance energisers that meet AS3350.2.76 or IEC60335.2.76 Supply Voltage + 0.7V. ±5% (design target) less then 1% over temperature range -5 to +50 o C Table 2 Specifications 14/02/07 Page 9 of 18

7.0 Installation Hardware installation Remove the 4 screws holding the top cover in place. Secure the PTE0700 to the wall or mounting device using the 4 mounting holes that will be hidden after the lid is replaced. Thread the 12-volt supply and any output leads into the Electric Fence Monitor enclosure through the cable gland on the side; be sure to tighten it to stop water or ants from entering. Attach a suitable insulated cable from the Electric Fence Monitor s red input binding post to the electric fence, and from the Electric Fence Monitor s green input binding post to a good earth connection. If possible, it is best to connect to the same earth that your energiser is using. Output Connections The Electric Fence Monitor s Output Connections are visible on the bottom edge of the circuit board and consist of a row of pluggable screw terminals. In Figure 1 the screw terminals, adjustment trimmers and LED s can be seen. They will be referred to in the remainder of this document. Voltage and Delay adjustment trimmers. LED s Output terminals along bottom edge of PCB. Figure 1 - Output Terminal Locations Expansion header for optional LCD. 14/02/07 Page 10 of 18

The cables shown should enter the enclosure of the Electric Fence Monitor through the cable gland on the side. The connections to the electric fence are not shown in Figure 1 because those cables are terminated at the binding posts outside the Electric Fence Monitor s enclosure. For security applications the Electric Fence Monitor can be configured for either Stand Alone or Alarm Panel Operation. Stand Alone Operation In Stand Alone Operation, the relay outputs can be used to switch a siren on when an alarm condition is raised. Battery or power pack. Figure 2 - Stand Alone Operation Alarm Panel Operation In Alarm Panel Operation, the relay outputs are connected to the alarm panel. See the documentation supplied with the Alarm Panel. Battery or power pack. Alarm Panel Figure 3 - Alarm Panel Operation 14/02/07 Page 11 of 18

Solar Panel Operation The PTE700 series monitors now have built in circuitry to charge a 12V lead acid battery (either sealed or a wet cell) from a solar panel. Only a 12V solar panel should be used, and its output power must not exceed 2W. 12 volt, 2 watt Solar Panel. 12V lead acid battery (sealed or wet cell) Figure 4 Solar Panel Operation Low Fence Voltage Set Point Calibration Automatic set point Turn the Volts trimmer fully anticlockwise Switch on the electric fence and ensure that it is operating in the expected range. Switch on the Electric Fence Monitor by supplying it with twelve volts. If the Electric Fence Monitor was already switched on, it needs to be reset by switching off (disconnecting the twelve volts supply) and switching back on. The Electric Fence Monitor has now automatically set the Low Fence Voltage Alarm Set Point and is now monitoring the Electric Fence. You can test its operation by deliberately placing a short on your electric fence the Electric Fence Monitor will raise an alarm. It is recommended that Automatic set point NOT be used for security purposes. If the fence starts with a medium voltage (due to a fault, for example) the monitor may perceive that the fence is OK when it is not. Low Fence Voltage Set Point Calibration Manual set point Turn the Volts trimmer fully anticlockwise and then advance it clockwise slightly. If you do not advance the trimmer, the Electric Fence Monitor will think that it is to automatically calibrate. Switch on the electric fence and ensure that it is operating in the expected range. 14/02/07 Page 12 of 18

Switch on the Electric Fence Monitor by supplying it with twelve volts. The Green Pulse LED should be flashing, indicating a working fence. The Low Fence Voltage Alarm Set Point is very low at present, because the Volts trimmer is turned almost completely anticlockwise. Gradually increase the set point by slowly turning the trimmer clockwise. The Low Fence Voltage Alarm Set Point is slowly increasing and will soon rise above your electric fence s voltage. When this happens, the Green Pulse LED will stop flashing, the Red Low LED will flash and after the delay set on the delay trimmer, the Fail LED, alarm beeper and relay will activate. The Low Fence Voltage Set Point is now about the same as your electric fence s voltage and needs to be lowered slightly. Do this by turning the Volts trimmer anticlockwise until the Greed Pulse LED begins to flash again. If the alarm came on it will self clear in about 30 seconds. Delay Calibration automatic and manual low fence voltage alarm set point. After setting the Volts trimmer (or using automatic setpoint) as above. The Green Pulse LED should be flashing. Switch off the electric fence OR place a short across the live to ground to remove the voltage at the monitor. Note the amount of time taken for the Electric Fence Monitor to raise an alarm. Turn the Delay trimmer anticlockwise to reduce the delay and clockwise to increase the delay. The shorter the delay is, the more likely the Electric Fence Monitor is to raise a false alarm, because every electric fence will have an occasional low voltage pulse. Switching the electric fence back on or removing the short will cancel the alarm after about 30 seconds; the Green Pulse LED should begin to flash again. 14/02/07 Page 13 of 18

8.0 Electric Fence Monitor Outputs LED Visual Display All Models The Electric Fence Monitor status can be visually inspected via the three provided LEDs 1. The Pulse (Green) LED will pulse green for each input pulse which exceeds the setting of the Volts trimmer. If the input voltage is below the setting the Low (centre RED) LED will pulse on. If the voltage is low (or off) for a time as set by the delay trim the Alarm LED will light. Note that the PTE0702 has a fail safe output. In this case the Alarm LED is green. The PTE0702 will show a green Alarm LED when the fence voltage is good and it will go out when the voltage is low. Relay Output All Models The Electric Fence Monitor Relay has three terminals. These three terminals are: Common [C], Normally Closed [NC] and Normally Open [NO.] When the fence is operating correctly and when there is no power supply for the Electric Fence Monitor, the C and NC terminals are shorted, and the NO terminal is not connected to anything. When the fence voltage goes low and the Electric Fence Monitor raises an alarm, the relay toggles, connecting the C and NO terminals, and disconnecting the NC terminal. These contact are intended to be connected to external alarm panels inputs, sirens or strobes. Terminal NC C NO Function Normally Closed Common Normally Open Table 3 Relay Connections NOTE: The relay contacts are rated at 30V, 1A (<500mA recommended). They MUST NOT be used to switch 240Vac. The Relay is fail safe on the PTE702 only. This means that in the alarmed condition, the C and NC terminals are shorted. 1 The Remote Monitor will need to be opened for this feature to be used. When not using this feature the unit should remain closed to protect it from the elements. 14/02/07 Page 14 of 18

0-5V Analog Output PTE0700 Only The 0-5V Analogue Output is from terminals V and GND. The minimum suggested load resistance on the 0-5V output is 1k. The 0-5V analogue output voltage linearly represents the fence voltage ranging from 0-10kV, ie: Fence Voltage = (Analogue Output Voltage) x 2000 Note: The monitor has software filtering which is intended to give the average output over the last 4 pulses. 4-20mA Analog Output PTE0700 Only The monitor current loop output (terminal I) is a current sink (or passive transmitter). Wire the output so that current flows from positive supply (5-12V) through the input of the 4-20mA receiver equipment and then to terminal I. The current range of 4-20mA will linearly represent a fence voltage range of 0-10kV, ie: Fence Voltage = ( 0.625 x (Loop Current) ) 2.5 Take care to read the instructions for the receiving analog input device. RS232 Output PTE0701, PTE0702 Or PTE0703 The RS232 Output is available in two forms. The first is the default RS232 format for the PTE0701 and PTE0702. The second is used with the PTE0703 and is a more SCADA friendly output. Other formats may be available on request. Pin I (Tx) Gnd V (Rx) Function Transmit Ground Receive (used for negative biasing the transmit) Table 4 PTE0700 RS232 Connections 14/02/07 Page 15 of 18

PTE0701 and PTE0702 The output string is: V 5500 CR LF Where: 5500 is a representation of the fence voltage and CR is a carriage return and LF is a line feed. PTE0703 The receiving equipment should be programmed to expect a 6 character packet STX, voltage (4 ASCII), CR where STX is binary 2 and CR is a carriage return. At turn on the PTE0703 also transmits some diagnostics information (see below). This can be ignored by the receiver as it is not prefaced by an STX. Please note that while the PTE703 transmits 4 significant digits the basic accuracy is only 8 bit (2 digit). In the print out below 6117 represents 6.1kV. When no pulse is seen for over 4 seconds 0000 is sent. Ver 1.42 7/05/03 auto 0000 set 0116 del 0126 batt 0135 6117 6117 6117 6117 6117 6117 0000 0000 0000 0000 14/02/07 Page 16 of 18

Optional Display Board The PTE0700 series monitors now have the provision for an optional LCD display PCB. The PAE036 LCD Expansion PCB connects via a 10 way ribbon cable to the expansion header on the PTE0700 PCB. It is secured to the PCB via 4 standoffs (provided). The display will show the low voltage setpoint and the actual fence voltage. It also displays a battery symbol when the supply voltage falls below a satisfactory level. Note that the LCD board must be removed to adjust the Low Voltage and Delay set point trimmers. Figure 5 PAE036 LCD Expansion PCB 14/02/07 Page 17 of 18

9.0 Warranty The PTE0700 Electric Fence Remote Monitor Series is covered by a 12-month warranty against defective parts or workmanship. If you have any problems, return the Monitor to Pakton Technologies Pty Ltd along with your proof of purchase, or contact the store of purchase or distributor. For assistance If you have any operational problems, difficulties etc. call our FREE HELP LINE: 1800 249 642 (within Australia only and not from mobile phones) Alternatively, phone fax or email your questions or comments to Pakton: Phone (07) 3888 3793 International +61 7 3888 3793 Fax (07) 3888 4330 International +61 7 3888 4330 E-mail: sales@pakton.com.au Mailing address: PO Box 408 Narangba QLD 4504 Australia Street address: 16 Ferrier Road NARANGBA Qld 4504 Australia More help is available at the WEB site: www.pakton.com.au 14/02/07 Page 18 of 18