Multiview Monitor / Controller

Similar documents
BAC-4000 Series AppStat

Carbon Monoxide Transmitter

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

Two-Channel Gas Controller

Series RSM Room Status Monitor. Specifications - Installation and Operating Instructions 5-13/32 [137.16] 8 [203.20] 4-5/8 [117.

RPM1600 Series Room Pressure Monitors

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

CLEANROOM MONITOR CR3A Network - Installation Instructions

MRMS Multi-Room Monitoring Station

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

EC-BOS-602/616 AX Security

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Oxygen (O2) Single-Point Gas Detection System

Lift Station Level Controller

opti-visor ultra-efficient chiller plant automation Typical specification

Intelligent Single Loop Fire Alarm Control Panel

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

Model D12-IR. Digital Gas Transmitter...

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Temperature Controllers

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Carbon Monoxide Transmitter

APPLICATION DATA SHEET

Cultivator & Hybrid Cultivator

NGC-40 Advanced Heat-Tracing Control System

Key benefits. Why Condair CP3?

AS950 REFRIGERATED SAMPLERS

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

Guide Specification - MasterFormat 2017 Style SECTION FLOW INSTRUMENTS PART 2 PRODUCTS 2.1 SECTION INCLUDES 2.2 ACCEPTABLE MANUFACTURERS

Model A1700 Series Annunciator

Addressable Fire Alarm Control Panel

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Wilo CO-Helix Booster Systems. Product Presentation July, 2017

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

I/O ZONE 560/583 USERS GUIDE

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

Introduction. What is the W2W Open controller?

Model SRPM Room Pressure Monitor. Installation and Operating Manual

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Process & TeMPerATUre UniversAl input DigiTAl MeTers

APPLICATION DATA SHEET

ACT2-CS Convenience Store Controller

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

AS950 PORTABLE SAMPLERS

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

IntesisBox BACnet/IP Server - Notifier ID3000 series

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

RAYCHEM NGC-30 COMPONENTS

SOLU T IONS / PRODUCT OVERVIEW

Multi-Gas-Controller MGC2

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

Flostop TS D7E and A8E. Operation Manual

SCC Inc. TS Series. Technical Instructions. Document No. TS 1000 June 25, TS Touchscreen Kits. Description. Touchscreen

CLIMAV 2.0 Thermoregulation Systems

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

C-TRAC3 COMMUNICATION MANUAL FOR. BACnet NOVEMBER 2010 TO JANUARY 2014 USA HEAD OFFICE AND FACTORY

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7

Process Alarm Module RTA 421

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

Networkable Fan Coil Controller Specification and Installation Instructions

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

The EN54 Part 2 & 4 Fire System

YOUR PARTNER IN FIRE & GAS DETECTION

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Danfoss gas detection units

ALTAIR 5X Multigas Detector Product Specification

AIRFLOW MEASUREMENT AND CONTROL PRODUCT CATALOG. Phone: 877-4GNTROL ( ) - Internet: GreenTrol.com. r1f

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

Contents. Appendix E: LonWorks Protocol Implementation Conformance Statement Document revision history... 47

configurable safety and programmable logic SLATE Integrated Combustion Equipment Management The revolutionary integration of

Product Data Sheet. Remote Terminals. Features:

XLH210: controller for gas leak detectors

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Advanced FireAlarm Panel 1-4Loop

MK Series. Remote Indicators For Line Isolation Monitors and Fault Location. Technical Bulletin NAE /

Bacnet Room Setpoint & Temp Display. Descriptions. Specifications

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

HTC-915-CONT. Heat-Trace Control system

LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls

Model A2100 Series Annunciator

REMOTE MONITORING AND ALARM SYSTEM

Manual Supplement. Product/System Title: Static Pressure Controller. Contents of this manual supplement include:

Intelligent addressable fire alarm control panel

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

MODEL 9010/9020 LCD CONTROL UNIT

4007ES Fire Control Panels

ComPak Series with CommandPak Control System CPCS BACnet MS/TP BAS Interface User s Guide DOCUMENT #: SVW06-CPBACNETMSTP

DNC-PS700-A10 Differential Pressure Control Meter. Operation and Installation Manual

70E Pressure Booster. Bell & Gossett. Bulletin D-215D. Efficient Operation. Easy to Select and Install. Quick Set-up through EZ Start

Analog Room Pressure Monitor RPC Series

Danfoss gas detection units

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

Transcription:

FEATURES: Bright/sunlight readable 7.0 LCD touch screen. Displays large, easy to read values, set points, room status, modes and alarms Up to six fully configurable Icons including: Environmental points Point or room status Point or room mode Display point values, set points, point status or space mode Local and remote audible and visual alarms Local set point, status and mode change Analog and digital input and outputs for point values, modes or status indicator Network for values, modes or status points Password protection and configurable user access restrictions Set point, status and mode networked or hardwired All parameters/settings saved in non/volatile memory Field configurable, easy, and intuitive menus. Easy and quick installation Input and output diagnostic screen Network communication debug screen TABLE OF CONTENTS Overview 1 Specification 2 Performance Characteristics 3 OVERVIEW: Multiview Monitor / Controller CRC-MVM The MultiVIEW is an advanced 7" LCD touchscreen display that is designed to be configured for any monitoring or sequencing application. Its core function is to give local access to critical information in an easy to read display. It's versatile design allows any of its on board analog, digital inputs, or network connections to drive the information being displayed on the screen. Additionally, any of the on board analog outputs or relays can be setup to drive a signal out to a BAS or peripheral device such as a valve or VFD. The MultiVIEW supports up to six (6) fully configurable graphical icons. The six graphical icons allow the facility user to view and/or make changes to point values, modes, status, set points, and alarms. The icons can be independently configured to retrieve their value from an analog input (0 5v, 0 10v, 4 20mA), digital input, or network communication. Typical Wiring 4 BaCnet Point Map 5-6 Additional Screens/ Installation 7-9 menclature/ordering 10 To support virtually any sequencing scenario, the four on board analog outputs and relays can also be configured to be driven by a point's alarm status, audible alarm status, current value, or set point value. The CRC MultiVIEW is excellently suited for any location where clear indication and user interface with critical information is required. CRC-MVM DATA SHEET 1 CRITICAL ROOM CONTROL

DISPLAY: Description: 7" Full color LED TFT 18 bit (262,144) color depth, sunlight viewable, 400cdm brightness, touch screen interface resistive touch (will work with gloved finger). Screen is capable of wipe down cleaning and water spray and dust resistant meeting (IP 54) Listing: CSA, RU(us), UL 60950, UL 94 V 0 (Enclosure) Main Screen: Display, alarm, and adjust set points for up to six environmental points COMMUNICATION: Connection: RS-485 Supported Protocol: BACnet MS/TP: Modbus, Johnson Controls Incorporated N2 & LON with optional card Network Debug: Network Setup: CONTROLLER I/O: Network communication diagnostics Baud rate, MAC address and instance ID configured via touch screen I/O Diagnostic: Graphical display of controller analog inputs/outputs and digital inputs/outputs Mounting: Low profile surface Analog Inputs: 4 total analog inputs AIN1 & AIN2 are selectable (4-20mA, 0-10V, or 0-5V) POWER REQUIREMENTS: Input Power: Power Draw: Primary: Class: 22 to 26VAC; 50/60Hz, fully isolated 20 VA 24 VAC Input Class 2 Energy Limiting, Class 130 (B) Insulation, Class 2 not wet, Class 3 wet Listing: CSA (c), RU (us) ANSI/UL 506, 508 1, 508 2 PRESSURE ALARMS: Audible: Visual: 1 (pressure alarm & remote alarm) 1 (amber (loss of pressure), red (alarm) ENVIRONMENTAL CHARACTERISTICS: AIN3 & AIN4 are (0-10V) (software selectable) Analog Outputs: 4: 0 10V or 0 5V (software selectable) Digital Inputs: 4 Relays: Terminals: Enclosure: Communication: Onboard power: 4 (normally closed - 0.5 A at 125 VAC; 2 A at 30 VDC) Removable screw terminals (18ga - 26ga wire) Fire retardant, extruded acrylic/pvc Alloy UL94V RS-485 10vdc (80mA max.), 5vdc (80mA max.), and onboard loop power circuit 22VDC (80mA max.) Temperature Limits: Storage: -40 to 180 Operating: +0 to 160 Compensated Range: +35 to 130 Temperature Coefficients: Zero: Span: Listing: ±0.03%F.S./ F ±0.03%F.S./ F UL-94-5VA CRC-MVM DATA SHEET 2 CRITICAL ROOM CONTROL

Instance Id Object Name Object Name Network changes saved in EEPROM AV 0 Current Value - Point 1 AV 1 Current Value - Point 2 AV 2 Current Value - Point 3 AV 3 Current Value - Point 4 AV 4 Current Value - Point 5 AV 5 Current Value - Point 6 AV 6 Set Point - Point 1 YES AV 7 Set Point - Point 2 YES AV 8 Set Point - Point 3 YES AV 9 Set Point - Point 4 YES AV 10 Set Point - Point 5 YES AV 11 Set Point - Point 6 YES AV 12 Alarm Status - Point 1 AV 13 Alarm Status - Point 2 AV 14 Alarm Status - Point 3 AV 15 Alarm Status - Point 4 AV 16 Alarm Status - Point 5 AV 17 Alarm Status - Point 6 CRC-MVM DATA SHEET 3 CRITICAL ROOM CONTROL

Instance Id Object Name Value Type Network chances saved in EEPROM AV 18 Alarm Low - Point 1 YES AV 19 Alarm Low - Point 2 YES AV 20 Alarm Low - Point 3 YES AV 21 Alarm Low - Point 4 YES AV 22 Alarm Low - Point 5 YES AV 23 Alarm Low - Point 6 YES AV 24 Alarm High - Point 1 YES AV 25 Alarm High - Point 2 YES AV 26 Alarm High - Point 3 YES AV 27 Alarm High - Point 4 YES AV 28 Alarm High - Point 5 YES AV 29 Alarm High - Point 6 YES AV 30 Point 1 AV 31 Point 2 AV 32 Point 3 AV 33 Point 4 AV 34 Point 5 AV 35 Point 6 AV 36 Analog Input 1 AV 37 Analog Input 2 AV 38 Analog Input 3 AV 39 Analog Input 4 BV 0 Digital Input 1 Read BV 1 Digital Input 2 Read BV 2 Digital Input 3 Read BV 3 Digital Input 4 Read CRC-MVM DATA SHEET 4 CRITICAL ROOM CONTROL

Additional Screens: CRC-MVM DATA SHEET 5 CRITICAL ROOM CONTROL

Installation Overview: The CRC-MultiVIEW is a two part system designed to reduce installation costs and eliminate problems that occur when wiring and pneumatic tubing have to be run down a wall. The two components are the CRC-LCD and the pressure transmitter/controller (CRC-DPT/CONT). te: Follow all local and federal electrical codes. Included Parts: (1) CRC-MultiVIEW-LCD w/faceplate (1) CRC-MultiVIEW-Control Unit (1) CRC-MultiVIEW-MB (Mounting Bracket) (1) CRC-RJ12 Crossover Cable (1) CRC-MultiVIEW Set Screw Installer Supplied Parts (t Included): (1) Three gang electrical box 24 VAC Power (18AWG recommended) Signal Wire (22AWG recommended) Mounting of the Monitor: The CRC-MultiVIEW-LCD and associated back plate (CRC-MultiVIEW-MB) is designed to be mounted directly to the wall using a standard three gang electrical box. The electrical box should be mounted flush relative to the face of the wall. The mounting bracket (CRC-MultiVIEW-MB) should be attached to the three gang electrical box. The CRC-MultiVIEW- LCD shall be slid down over mounting bracket and screwed in from the bottom. CRC-MVM DATA SHEET 6 CRITICAL ROOM CONTROL

Mounting of the CRC-MultiVIEW-Control Unit: The CRC-MultiVIEW-Control Unit is designed to be mounted remote from the monitor typically above the ceiling). The CRC-MultiVIEW-Control Unit is powered by 24VAC. CRC-MVM DATA SHEET 7 CRITICAL ROOM CONTROL

DIMENSIONS: 8.56 1.48 6.04 ORDERING NOMENCLATURE: ADDITIONAL PRODUCT INFORMATION: Please contact us at: Web: www.criticalroom.com Phone: 414.324.8978 Address: Critical Room Control 6643 West Mill Road Milwaukee, WI 53218 CRC-MVM DATA SHEET 8 CRITICAL ROOM CONTROL