Understanding Applications for Alternative Refrigerants

Similar documents
Understanding Applications for Alternative Refrigerants

DOE and EPA Impacts to Commercial Refrigeration

Refrigerant and Energy Regulations Update

Making Sense of the Latest Rulemaking on Acceptable Refrigerants. E360 Webinar

Refrigerant and Energy Regulations Update

Understanding Applications for Alternate Refrigerants. Ron Bonear Emerson Climate Technologies

How to Meet 2017/2020 Energy Regulations

Refrigerants Management & Retrofits. Mike Saunders & Randy Tebbe Emerson Climate Technologies

The Case for R-290 in U.S. Commercial Foodservice

Refrigerant & Energy Regulations Update

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA

New Refrigerants Designation and Safety Classifications

SOLSTICE L40X (R-455A)

Top Retailer Trends for Refrigeration, Controls and Facility Optimization. E360 Webinar March 6, 2018

The Current Path of Refrigerants

Effectively Managing the Transition to Lower GWP Refrigerants

Low GWP Refrigerants for Air Conditioning Applications

PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17

Meeting the Challenges of the EU HFC Phase-Down

The R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard

Honeywell Refrigerant Update

Solstice 452A (R-452A) Reduced GWP and Discharge Temperature for Transport Refrigeration, Plug-Ins and Condensing Units

Copeland Scroll ( HP) ZB*KA and ZF*KA for Refrigeration

Embraco Position Paper: Light Commercial Refrigeration

ZERO ZONE USER GUIDE TO THE 2017 EPA RETAIL FOOD REFRIGERATION REGULATIONS

Standards and Regulations Update for Flammable Refrigerants

REFRIGERANT CHANGEOVER

FACT SHEET 9 Large Air-Conditioning (air-to-air)

2017 Climate & Refrigerants Outlook. Stephen Yurek President & CEO

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

R-404A Alternative with Low Compressor Discharge Temperature

Chillers for High Ambient Conditions: What Technologies and Fluids?

Overview of New Refrigerants and Expected Market Trends

BRA FACT FINDER Number 19

Low Global Warming Refrigerants For Commercial Refrigeration Systems

Update on Codes and Standards Research. Karim Amrane, Ph.D. Senior Vice President

Research for the Development of Safety Standards

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

Stay in business: STOP installing R-404A / R-507A! R-404A R-507A

Flammability and the Low GWP Refrigerant Challenge

The impact of legislation and trends for the industry

Refrigerant changeover guidelines

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

Update on Next Generation Low GWP Refrigerants for Chillers Products. Steve Kujak Director, Next Generation Refrigerant Research

FACT SHEET 6 Transport Refrigeration

2016 Annual Conference

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Update on Opteon Refrigerants

AIRAH Victoria Refrigerants Update

Gary Parker Refrigerants Product Manager

GWP Alternative Refrigerants

TEST REPORT #34. Compressor Calorimeter Test of Refrigerant DR-7 in a R-404A Scroll Compressor

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) â Summary of Phase II Testing Results

Refrigerants. Refrigerants with the Future in Mind

Overview of refrigerant alternatives in the air conditioning sector *

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

Honeywell Refrigerants. Retrofit Guidelines. R-404A/R-507A to: R-448A Solstice N40

ANALYSIS OF LGWP ALTERNATIVES FOR SMALL REFRIGERATION (PLUGIN) APPLICATIONS

Energy Performance of Low Charge NH3 Systems in Practice. Stefan S. Jensen

see notes on refrigerant type Refrigerant Type ASHR AE Refrigerant Composition (Mass % ) Zeotropes

R-407A R-448A R-449A

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Information for practitioners 5. Refrigerant selection guidelines. An overview of the refrigerants of the future.

AE R4 July 2015 Guide for the Use of R-290 Refrigerant in Copeland Refrigeration Compressors

Gary Parker Refrigerants Product Manager

Possibilities of the RAC sector transformation a technical perspective

New F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation

4/19/2013. The Changing State of Refrigerants

Low GWP alternative refrigerants to R404A

Scroll Chillers Transition from HCFC-22 to HFCs

Low GWP Refrigerants for Air Conditioning and Chiller Applications

Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

10/4/2013. The Changing State of Refrigerants

A2L Refrigerants. Objectives 14/09/2017

New Refrigerants & Selecting Capital Equipment

Natural Refrigeration with Hydrocarbons Emerson s R290 Solutions

Go Beyond Cool. coldroom.danfoss.co.uk. Danfoss Solutions for Cold Rooms Installers/Contractors, Europe. Over

Performance Rating of Commercial and Industrial Unitary Air-Conditioning Condensing Units

PRICE CHOPPER SARATOGA, NY. First cascade supermarket system in North America Installed and Started March of 2008

Refrigerant Glide and Effect on Performances Declaration

Natural Refrigerants.

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe. Over

A Primer on HFOs. Hydrofluoro-olefins Low-GWP Refrigerants. Brett Van Horn, PhD Arkema Inc.

Large AC units using a variety of low-gwp options

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

CO 2 transcritical FTE System Full Transcritical Efficiency

Effectively Managing the Transition to Lower GWP Refrigerants

Application Engineering

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

International New Technology and Refrigerant Symposium

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Alternatives to HCFC/HFC refrigerants for high ambient temperatures

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

System Drop-in Tests of R-134a Alternative Refrigerants ARM-42a and R-1234ze(E) in an Air- Cooled Screw Chiller and a Water-cooled Centrifugal Chiller

Technical Information

Transcription:

Understanding Applications for Alternative Refrigerants E360 Forum Raleigh, N.C. March 1, 2017 Todd DeVore Director Technical Support Services Emerson

Disclaimer This presentation is intended to highlight changing developments in the law and industry topics. The law is frequently evolving and information and publications in this presentation may not reflect the latest changes in the law or legal interpretations. The statements and information provided in this presentation should not be construed as legal advice or legal opinion regarding any specific facts or circumstances, but is intended for general informational purposes only. The views and statements expressed during this presentation are the personal opinions of the presenter and do not represent those of Emerson Climate Technologies, Inc. or its affiliated companies. You should consult an attorney about your situation and specific facts and you should not act on any of the information in this presentation as the information may not be applicable to your situation. Although all statements and information contained herein are believed to be accurate and reliable, they are presented without warranty of any kind. Information provided herein does not relieve the user from the responsibility of carrying out its own tests and experiments. Statements or suggestions concerning the use of materials and processes are made without representation or warranty that any such use is free of patent infringement and are not recommendations to infringe on any patents. This presentation may not be copied or redistributed without the express written consent of Emerson Climate Technologies, Inc. 2

Is it reliable? Goals for Today s Discussion Brief discussion on industry drivers Communicate differences in applying lower-gwp A1 refrigerants Reliability and performance Discuss which challenges face the different channels OEM, wholesalers, contractors, end users Update on A2L/A3 refrigerants Industry activity Emerson s readiness and facility investment 3

Refrigerant Options Pressure or Capacity R-410A Like CO 2 A1 Non-Flammable A2L Mildly Flammable R-447B = L41z; R452B = XL55 L41y, R459A=ARM-71a R-32/HFO 400 675 Blends R-32 A3 Flammable B2L Toxic, Mildly Flam. Available now OEMs testing R-410A Qualitative Not to Scale Established R-404A & R-407/22 Like NH 3 R-290 R444B = L20 L40 ~300 R-454A = XL40 <150 ARM-20b R-455A = L40x(HDR110) R-454C = XL20 R-457A=ARM-20a ARM-25 R-448A = N40 R-449A = XP40 R-449B = ARM-32 N20 < 1500 R32/HFC/HFO Blends R-22 R-407A R-407C R-407F, R-452A = XP44 R-452C=ARM-35 R-404A R-507A (3,922) R-134a Like R-123 Like (V. Low Pr.) HFO 1234yf HFO 1234ze ARM-42 DR2, HFO 1233zd R-515A ~600 R-513A = XP10 R-450A = N13z 0 500 1,000 1,500 2,000 R134a GWP Level HFC/HFO Blends Lower-GWP Synthetic Refrigerants, Blends and Natural Refrigerants Are Available Options in Various Applications. 4

EPA s Final Rule, July 20, 2015, and September 26, 2016 Changed listing status of certain HFCs* Final Rule: July 20, 2015 Final Rule: September 26, 2016 Phase-out refrigerant Supermarket (New**) Supermarket (Retrofit***) Remote condensing unit (New) Remote condensing unit (Retrofit***) MT < 2,200 BTU/hr. and not contain flooded evap. (New) Stand-Alone MT 2,200 BTU/hr. with or without flooded evap. (New) LT (New) LT and MT (Retrofit***) Refrigerated food processing and dispensing equipment (New) Cold storage warehouses (New) Ice machines (New) Very lowtemp refrigeration (New) R-404A/507A Jan. 1, 2017 July 20, 2016 Jan. 1, 2018 July 20, 2016 Jan. 1, 2019 Jan. 1, 2020 Jan. 1, 2020 July 20, 2016 Jan. 1, 2021 ^Jan. 1, 2023 OK OK R-410A OK - OK - Jan. 1, 2019 Jan. 1, 2020 Jan. 1, 2020 - Jan. 1, 2021 ^Jan. 1, 2023 OK OK R-407A/C/F OK OK OK OK Jan. 1, 2019 Jan. 1, 2020 Jan. 1, 2020 OK ^Jan. 1, 2021 R-407C/F OK R-407A: ^Jan. 1, 2023 OK R-407C only HFC-134a OK OK OK OK Jan. 1, 2019 Jan. 1, 2020 OK OK OK OK OK - Likely alternatives (Emerson perspective) R-448A/449A OK OK OK OK Neither SNAPapproved, nor banned Neither SNAPapproved, nor banned OK OK for LT only - - OK - R-450A/513A OK OK OK OK OK OK OK OK OK OK OK - R-290 - - - - OK OK OK - - - OK OK R-744 OK - OK - OK OK OK - OK OK - OK R-717 OK (in primary loop of secondary system) - OK (In primary loop of secondary system) - OK (in primary loop of secondary system) OK (in primary loop of secondary system) OK (in primary loop of secondary system) OK (in primary loop of secondary system) OK (in primary loop of secondary system) OK OK - ** Includes ice machines connected to a supermarket rack refrigeration system. *** EPA uses term retrofit to indicate the use of a refrigerant in an appliance that was designed for and originally operated using a different refrigerant. Term does not apply to upgrades to existing equipment where the refrigerant is not changed. *Abbreviated For complete listing, see EPA Final Rule; go to: https://www.gpo.gov/fdsys/pkg/fr-2015-07-20/pdf/2015-17066.pdf See EPA Final Rule; go to: https://www.epa.gov/sites/production/files/2016-09/documents/snap_status_change_rule_2_2060_as80.pdf 5

Refrigeration Application Alternatives Emerson s Approvals in Progress or Complete A1 Non-flammable A2L Mildly flammable A3 Flammable B2L Toxic, mildly flam. Volumetric Capacity / Pressure Elevated Medium R-404A like Low R-134a like Naturals R-744 (CO 2 ) 1 R-290 (Propane) 3 R-717 (Ammonia) 0 Mildly Flammable (A2L) HFO and Blends R-455A (HDR-110) 146 R-454C (XL20) 146 R-457A (ARM-20a) 139 HFO-1234yf <1 HFO-1234ze <1 ARM-42 131 Lowest GWP Non-Flammable (A1) HFC/HFO blends R-449A (XP40) 1,282 R-448A (N40) 1,273 R-449B (ARM-32) 1,296 R-513A (XP10) 573 R-450A (N13) 547 R-515A 392 Today s Non-flammable (A1) HFCs R-407A 1,923 R-507A R-407C 3,985 1,624 R-404A R-407F 3,943 1,674 R-134a 1,300 GWP 0 5 0 150 350 1,300 1,300 4,000 This List Is Subject to Change. Please Check Publication, Form 93-11 or With Emerson Representatives for the Most Current Approvals in Progress. 6

Is it reliable? Goals for Today s Meeting Brief discussion on industry drivers Communicate differences in applying lower-gwp A1 refrigerants Reliability and performance Discuss which challenges face the different channels OEM, wholesalers, contractors, end users Update on A2L/A3 refrigerants Industry activity Emerson s readiness and facility investment 7

What Should a Compressor Manufacturer Do to Qualify a New Refrigerant? OEMs Should Verify the Compressor Manufacturer Has Done Due Diligence Before Applying New Refrigerants to the Product. 8

Condensing Temp, F R-404A A1 Low-GWP Alternatives Have Higher Heat of Compression 150 Medium-Temperature Operating Envelope ZSKA 140 130 120 110 100 90 80 70 60 404A 231 F 448A 273 F 404A 199 F 448A 224 F 50 Internal discharge line temperature 6 inches from compressor discharge 40-15 -5 5 15 25 35 45 Evaporating temp, F R-448A and R-449A have similar temperature profiles. Increase in Discharge Temperature Dependent on Condition 9

Condensing temp, F Condensing temp, C R-404A vs. R-448A Operating Envelopes ZS**KA Example Evaporating temp, C -40-34 -29-23 -18-12 -7-1 4 10 160 150 140 130 120 110 100 90 80 70 60 50 40 30-40 -30-20 -10 0 10 20 30 40 50 Evaporating temp, F 71 66 60 54 49 43 38 32 27 21 16 10 4-1 Check Application Engineering Bulletin Before Applying the Same Compressor in Application With Different Refrigerants. 10

Condensing temp, F Models With Liquid Injection Can Still Run Full Operating Envelope Capabilities 160 150 140 130 ZF**K4E operating envelope R-404A/R-407A/R-448A/R-449A 120 110 100 90 80 70 60 50 40 30-40 -30-20 -10 0 10 20 30 40 50 Evaporating temp, F Compressors Running Higher Heat of Compression Refrigerants Can Run Reliably With Injection; More Power Will Be Consumed. 11

Condensing Temp, F R-134a A1 Alternatives Have Very Similar Heat of Compression Characteristics 150 Example of extended medium-temperature operating envelope 140 130 120 110 134a 171 F 450A 166 F 513A 174 F 100 90 80 134a 160 F 450A 155 F 513A 144 F 70 60-30 -20-10 0 10 20 30 Evaporating Temp, F Operating Envelopes for R-450A and R-513A Equivalent to R-134a Maps 12

Drivers of System Capacity: Refrigerant Density Evaluate R-448A density relative to R-404A/R-407A Capacity Driven by Refrigerant Density and Enthalpy 13

Drivers of System Capacity: Refrigerant Enthalpy Evaluate R-448A theoretical enthalpy relative to R-404A/R-407A Capacity Driven by Refrigerant Density and Enthalpy 14

Scroll MT Dew Point Capacity R-404A vs. R-407A/R-448A (20/120) 15

Scroll MT Mid/Dew Point Capacity R-404A vs. R-407A/R-448A (20/120) Why is this delta important? 16

Mid-Point vs. Dew Point and the Refrigeration Cycle Heat exchangers (condenser and evaporator) operate at midpoint (or bubble/dew) conditions Compressors see dew point conditions When there is no glide and assuming little/no pressure drop, the temperature at mid-point = temperature at dew point. Assume negligible pressure drop effects. 17

Mid-Point vs. Dew Point and the Refrigeration Cycle (continued) But when there is glide Bubble Dew Per AHRI standards, compressors are rated based on dew point pressure/temperatures. Temperature When there is glide and assuming little/no pressure drop, the temperature at mid-point temperature at dew point. Assume negligible pressure drop effects. 18

Scroll LT Mid/Dew Point Capacity R-404A vs. R-407A/R-448A (-25/105) Compressor sizing should be done off of midpoint. 19

Scroll MT Mid/Dew Point Weighted EER R-404A vs. R-407A/R-448A 20

Scroll LT Mid/Dew Point Weighted EER R-404A vs. R-407A/R-448A 21

Temperature Glide Is Significant for A1 R-404A Replacements, not so for R-134a Refrigerant Temperature Glide F R-404A ~1 F R-407A ~8 F R-448A ~7 F R-449A ~7 F R-134a 0 F (single component) R-450A ~1 F (near azeotrope) R-513A 0 F (azeotrope) Significant considerations needed for temperature glide (system component sizing, etc.) No glide considerations necessary 22

Capacity (Btu/Hr) Capacity (Btu/Hr) Hermetic LT Capacity R-134a vs. R-450A/R-513A 1600 R-450A/R-513A vs. R-134a Capacity 5/95 40 F RG 3000 R-450A/R-513A vs. R-134a Capacity -10/120 40 F RG 1400 1200 1000 R-134a baseline -14.1% vs. R-134a +4.0% vs. R-134a 2500 2000 R-134a baseline -14.7% vs. R-134a +7.0% vs. R-134a 800 1500 600 1000 400 500 200 0 R-134a R-450A R-513A 0 R-134a R-450A R-513A Compressor: AFE12C4E 23

WEER Hermetic HT Weighted EER R-134a vs. R-450A and R-513A 9.00 R-450A/R-513A vs. R-134a WEER (65 F return gas) 8.00 7.00 6.00 R-134a baseline -0.5% vs. R-134a -1.2% vs. R-134a 5.00 4.00 3.00 2.00 1.00 0.00 R-134a R-450A R-513A Compressor: ARE51C4 Weighted EER Condition = 20% (20 Evap / 120 Cond) + 80% (20 Evap / 70 Cond) 24

Is it reliable? Goals for Today s Meeting Brief discussion on industry drivers Communicate differences in applying lower-gwp A1 refrigerants Reliability and performance Discuss which challenges face the different channels OEMs, wholesalers, contractors, end users Update on A2L/A3 refrigerants Industry activity Emerson s readiness and facility investment 25

Alternate Refrigerants Challenges Through the Channel OEM Wholesaler Contractor End User Component selection SKU proliferation Training Regulatory compliance System redesigns Counter-training Retrofit challenges Sustainability goals Engineering resources Inventory planning Energy consumption Testing constraints Short-term vs. Long-term change 26

Is it reliable? Goals for Today s Meeting Brief discussion on industry drivers Communicate differences in applying lower-gwp A1 refrigerants Reliability and performance Discuss which challenges face the different channels OEMs, wholesalers, contractors, end users Update on A2L/A3 refrigerants Industry activity Emerson s readiness and facility investment 27

Other Refrigerant, Standards, Code-Related Activity Federal acquisition regulation encouraging low-gwp usage in federal buildings Safety standards under revision to include mildly flammable refrigerant (A2L) accommodations U.S.: UL 1995, ASHRAE 15 Target late 2017 International: ISO 5149, IEC 60335, EN378 Target late 2017 Section 608 revisions to refrigerant management now include HFCs https://www.epa.gov/section608/revised-section-608-refrigerantmanagement-regulations Evaluating revisions on increasing charge limits for flammables U.S. A3 charge limit from 150g to 300g 500g Building codes for mildly flammable (A2L) refrigerants being expedited for adoption in 2021 code cycle $5.2M partnership by AHRI, ASHRAE, DOE to study flammable refrigerant behavior in real-world applications Refrigerant-related Changes Are Global in Scope; We Have to Stay on Top to Remain Competitive. 28

Emerson Is Investing in A3/A2L Testing Capability to Be Prepared A3/A2L performance stands (10 200K) Life test stands Ambient chamber (0 F 120 F) Functionality Coming Online Throughout 2017 29

Thank You! Questions? DISCLAIMER Although all statements and information contained herein are believed to be accurate and reliable, they are presented without guarantee or warranty of any kind, expressed or implied. Information provided herein does not relieve the user from the responsibility of carrying out its own tests and experiments, and the user assumes all risks and liability for use of the information and results obtained. Statements or suggestions concerning the use of materials and processes are made without representation or warranty that any such use is free of patent infringement and are not recommendations to infringe on any patents. The user should not assume that all toxicity data and safety measures are indicated herein or that other measures may not be required. 30