Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Similar documents
Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Design and Development of Combined Direct and Indirect Evaporative Cooling System

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

PERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED

Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Keywords : Evaporative cooling, Saturation efficiency, Cooling capacity, Cooling pad, Cellulose, Aspen, Coconut coir. IJSER

*Corresponding author;

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Modified Air Cooler with Split Cooling Unit

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

Enhancement of COP in Vapour Compression Refrigeration System

Numerical Simulation of Window Air Conditioner

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Chapter 14, Problem 27.

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

solution, due to the partial vapor pressure difference between the air and the desiccant solution. Then, the moisture from the diluted solution is rem

AR/IA/UP 241 Lecture 5: Psychrometrics

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

ANALYSIS OF DESICCANT COOLING SYSTEM

International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 ISSN

Design, Manufacturing of Chilled Water System for Process Cooling Application

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

EXPERIMENTAL STUDY OF AIR FLOW RATE EFFECTS ON HUMIDIFICATION PARAMETERS WITH PREHEATING AND DEHUMIDIFICATION PROCESS CHANGING

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

η second law = Second law efficiency

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec REFRIGERATION & AIR-CONDITIONING (Mechanical Engineering)

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

II. OBJECTIVE OF RESEARCH

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis

ABSTRACT I. INTRODUCTION

International Journal of Advanced Engineering Research and Science (IJAERS) Vol-3, Issue-2, Feb- 2016] ISSN:

Two Stage Indirect/Direct Evaporative Cooling

Energy and Exergy Analysis of an Ejector-Absorption Refrigeration Cycle with Using NH3-H2O as the Working Fluids

Volume 2, Issue 1 (2014) ISSN International Journal of Advance Research and Innovation

Performance Study of Triple Concentric Pipe Heat Exchanger

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

Mathematical Simulation of Longan Fruit Drying

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

ISSN Vol.08,Issue.21, November-2016, Pages:

Energetic vs. Exergetic Efficiency of Food Drying Via Forced Convection with and without Electrohydrodynamic Enhancement

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

ADVANCES in NATURAL and APPLIED SCIENCES

Dynamic performance of a novel dew point air conditioning for the UK buildings

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Energy Consumption Reduction of AHU using Heat Pipe as Dehumidifier

Investigation of an evaporative air cooler using solar energy under Algerian climate

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

COMPARATIVE ANALYSIS OF SINGLE AND DOUBLE EFFECT LiBr-WATER ABSORPTION SYSTEM

Global Journal of Engineering Science and Research Management

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 01, 2016 ISSN (online):

Design and Development of Water Cooled Condenser for Domestic Refrigerator

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Impact of indirect evaporative air cooler type on the performance of desiccant systems

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Experimental Analysis and Performance Comparison between Evaporative Cooling System and Air Conditioning System

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Scholars Research Library

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

Performance Study on A Window Type Air Conditioner Condenser Using Alternative Refrigerant R407C

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Transcription:

International Journal of Thermal Technologies E-ISSN 2277 4114 2015 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijtt/ Research Article Effect of Operating Parameters on the Performance of Direct Evaporative Cooler Abdul Kareem R. Abed * Middle Technical University, Engineering Technical College, Baghdad -Iraq Accepted 25 Sept 2015, Available online 30 Sept 2015, Vol.5, No.3 (Sept 2015) Abstract Evaporative air cooler is an effective device in cooling private houses in Iraq, and used commonly in this country for many reasons, the mean one is due to the lack in power supply. An evaporative cooler of 5000 cfm capacity (8500 m 3 /hr.) was studied under extremely hot Iraqi weather. The outdoor temperature was varied from 30 to 60oC, while the outdoor relative humid was varied from 10 to 60%. The results showed that Relative humidity affect both effectiveness and exergy efficiency more than another key variables, the exergy of water circulated in evaporator cooler was spend in destruction the exergy of hot air. The more destruction in exergy through evaporative cooler gives the higher exergy efficiency. The exergy efficiency of the cooler was deteriorated significantly in hot and humid weather. Keywords: Evaporative cooler, Effectiveness, exergy destruction, Second law efficiency. 1. Introduction 1 Evaporative coolers are commonly used in Iraq due to the lack in power supply, therefore most of private houses in this country contains more than one cooler. Accordingly, the consumption of electrical power and water by his devices are hug. So, many works are required to improve the performance of evaporative cooler. A simple methodology in design house hold desert cooler was introduced by (Kachhwaha, et al, 2010):, this method was used to predict the performance of evaporative medium, pad thickness and height for cooler. Modelling and optimization analysis for cooling system in the building were introduced by (Taufiq et al, 2007).. Exergy technique has been used in them work. They found that this method is well suited for analyzing thermodynamic model and identified exergy losses of air conditioning application in a building. (Musa, 2008) studied evaporative cooling processes comprising of direct, indirect, combined direct and indirect and also desiccant based types. A theoretical studies covering the heat and mass transfer as well as psychometric associated with evaporative cooling were. The basic principles of the direct evaporative cooling process for human thermal comfort, was presented by (Camargo, et. al, 2009) experimental results were introduced also. (Gómez, et. al, 2010) introduce the thermodynamic basis for saturation process in evaporative air cooler. The work extended to study legionnaire s disease in commercial evaporative. A heat and mass transfer mathematical model was developed by (Bisoniya, et. al, 2011), the model was used to simulate the properties of indirect evaporative cooler. The work was supported by experimental wok, The theoretical and experimental results were compared and analyzed. The theoretical model can be used to predict the performance of modified indirect evaporative cooler. In this work, an energy and exergy analysis of a direct evaporative air cooler was introduced under Iraq conditions. The performance of evaporative cooler of 5000 cfm capacity ( 8500 m 3 /hr) was studied for different inlet dry bulb temperature and different relative humidity of air. 2. Thermal analysis The heat transfer in evaporative cooler consist of two types, the first was sensible heat that transferred from hot air to cold water by convection, and the second is latent heat transfer due to mass transfer from saturated air to moist air. The total heat transfer in cooler can be written as: (1) While the convective heat transfer air depends on the convective heat transfer coefficient and temperature difference between surface and air stream temperature. *Corresponding author: Abdul Kareem R. Abed ( ) (2) 244 International Journal of Thermal Technologies, Vol.5, No.3 (Sept 2015)

Abdul Kareem R. Abed The latent heat transfer, depends on the evaporated water mass and latent heat of evaporation as follow (Kachhwaha, et al, 2010): (3) control volume are the saturated air exergy as well as the exergy associated with water vapour. Control volume The mass of vapour produced can be calculated as follows: ( ) (4) Substitute equations (2, 3 and 4) into equation (1) yields a. ψ a,i a. ψ a,e w. ψ v,e w. ψ w,i ( ) ( ) (5) The enthalpy of moist and dry air can be written as function of dry bulb temperature for moist air, While for saturated air it can be written as a function of circulated water bulk temperature. (Baker, et al, 1961) ( ) (6) ( ) (7) The solution of equations (5, 6 and 7) are as follows(stoecker, et al 1958): ( ) ( ) (8) Where is specific heat of the air-water vapor mixture (kj/kg K), and can be written as: Fig. 1 Exergy flow through evaporative cooler Tus the exergy destruction in EAC can be written depending on the exergy balance equation, as follows (Claus, et al 2013): ( ) ψ ψ ψ (13) Since study state condition and adiabatic saturation are assumed through EAC, then, the exergy destruction through EAC can be written as: ψ ψ ψ ψ ψ (14) The exergy efficiency for EAC is related to exergy enter the C.V and the exergy destruction as follows (Taufiq et al, 2007) ( ) (9) (15) Substitute equations (8) and (9) into equation. (5) and neglecting the term ( ) yields the final equation of heat transfer in evaporative cooler (Baker, et al, 1961): ( ) (10) The effectiveness of the evaporative cooler is found from the following equation: (11) The total mass of evaporated water is calculated as follows: ( ) (12) 3. Exergy analysis Figure 1 shows the evaporative air cooler (EAC) as a control volume, it can be seen from the figure that the exergies entering EAC are the moist air exergy and makeup water exergy, while the exergies leaving The exergy of water is: ψ ( ) ( ) (16) The exergy of water vapour leaving EAC is (Marletta, et al, 2010): ( ) ( ) ( ) (17) While the exergy of air consist of three terms, namely, chemical, thermal and mechanical exergy, the last term is neglected usually, since this term depends on pressure loss through EAC (Kloppers, et al,2005). The chemical exergy of air can be written as: *( ) + (18) While, the thermal exergy is: ( ) (19) 245 International Journal of Thermal Technologies, Vol.5, No.3 (Sept 2015)

Then, the exergy of air is the summation of chemical and thermal exergies as follows: ψ (20) 4. Results and discussion The effectiveness of such case is very low as shown in Figure 4, it can be seen from the figure that EAC operate at low RH gives higher effectiveness for different inlet DBT of air, while, when the RH reaches 60% the effectiveness of the cooler reduces significantly for all values of RH. The performance of EAC was studied under arid and normal climates, the range of outdoor dry bulb temperature was in the range of 35 to 50 o C in step of 2.5 o C, while the relative humidity was varied from 10 to 60% in step of 10%. Figure 2 shows the effect of entering air DBT on the leaving air DBT from EAC for different values of outdoor relative humidity (RH), it can be seen from the figure that at low relative humidity the cooler gives low DBT of leaving air, this because that, dry air can contain more water vapour than moist or saturated air. As the relative humidity reaches 60% the difference between inlet and outlet DBT reduces significantly. Fig. 4 Evaporative cooler effectiveness vs inlet DBT for different relative humidity Fig. 2 Outlet DBT vs inlet DBT at different relative humidity Therefore the use of evaporative cooler under such conditions is limited. The EAC consumption of water related with cooler effectiveness as shown in Figure 5, it can be seen from the figure as the DBT close to WBT the ability of air to contain water vapour reduces, hence less water is evaporated. Thus, evaporative cooler works at high ambient relative humidity consumed less water even DBT is low. while, at low relative humidity the consumption of water increases rapidly. This effect reflects on the WBT as shown in Figure 3, it can be seen from the figure that at 60% RH and 60 o C DBT the WBT of leaving air approach entering DBT thus entering air approaches saturation conditions. Fig. 3 Outlet DBT vs WBT at different relative humidity Fig. 5 Water consumption vs inlet air DBT Also, the figures shows that the consumption of water increases with increasing of DBT, due to high sensible heat transfer between air and water. Figure 6 shows the variation of inlet and outlet moisture when the outdoor relative humidity of 10 and 60%, it can be seen from the that, the moisture content increases with increasing of both outdoor DBT and relative humidity. 246 International Journal of Thermal Technologies, Vol.5, No.3 (Sept 2015)

Figure 10. Also, the figure shows a significant deterioration in exergy efficiency when the inlet air conditions of 60 o C DBT and 60% RH. Fig. 6 Moisture content vs inlet DBT The difference between inlet and outlet air moisture content shows a significant value when the outdoor RH is 10%, while, as the relative humidity increases to 60 the air equipped less amount of water vapour, which is reflect negatively on the evaporative cooler effectiveness, as mentioned previously. As the entering DBT increases the destruction in exergy through cooler increases also, as shown in Figure 7. Fig. 8 Exergy efficiency vs inlet DBT Fig. 9 Effect of RH on the outlet DBT and WBT of leaving air, as well as water consumption Fig. 7 Effect of inlet DBT on the exergy destruction This is due to the increasing in entropy generation that caused by formulation of water vapour. This phenomena, gives a clear impression that the exergy of water is consumed in destroyed the exergy of air. Thus, a more exergy destruction means a lower exit DBT. Therefore, the exergy efficiency of evaporative cooler increases with the increasing of exergy destruction, as shown in Figure 8. The effect of relative humidity on the outlet leaving air DBT and WBT, as well as, water consumption is shown in Figure 9, when the inlet DBT equals 40 o C. It can be seen from the figure that increases in relative humidity tend to increase both DBT and WBT of exit air and reduces water consumption. The increases of outlet DBT means less effectiveness and less exergy efficiency as shown in Fig. 10 Effect of RH on the effectiveness and exergy efficiency of the cooler Conclusions From above it can be conclude that: 1- Relative humidity was the dominated factor that affecting cooler effectiveness. 247 International Journal of Thermal Technologies, Vol.5, No.3 (Sept 2015)

2- The exergy of water is consumed in destruction the exergy of air through the evaporative cooler. 3- As the exergy destruction through evaporative cooler increases the exergy efficiency of cooler increases also. Nomenclature A Area m 2 cpa Specific heat of air at constant pressure kj/kg. K cv Specific heat of vapour at constant pressure kj/kg. K H Enthalpy kj/kg hm mass transfer coefficient kg/m 2 s Mass flow rate Kg/s P Pressure kpa Q Heat transfer kw Ra Air gas constant kj/kg.k S Entropy kj/kg. K t Time s. T Temperature oc / K V Volume m 3 W Work kj/kg Greek Symbols ηexe Exergy efficiency Relative humidity/ control volume exergy --/ kj/kg Exergy kj/kg Moisture content kgw/kga Subscripts A Air C.V. Control volume Chem. Chemical Dest. Destruction E Exit Fg Fluid gas i Inlet l Latent o Dead state S Sensible Sat Saturated T Total th. Thermal V Vapour W Water References Baker, Donald R. and Howard A. Shryock, (1961). A comprehensive approach to the analysis of cooling tower performance. Journal of Heat Transfer 83.3: 339-349. Bisoniya, Trilok Singh, S. P. S. Rajput, and Anil Kumar, (2011). Comparative thermal analysis of theoretical and experimental studies of modified indirect evaporative cooler having cross flow heat exchanger with one fluid mixed and the other unmixed. Journal homepage: www. IJEE. IEE Foundation. org 2.5: 921-932. Camargo, J. R., C. D. Ebinuma, and S. Cardoso (2009). A mathematical model for direct evaporative cooling air conditioning system. Revista de Engenharia Térmica 2.2. Claus Borgnakke and Richard E. Sonntag, 2013. Fundamentals of Thermodynamics, 8 th ed.,, John Wiley & Sons, Inc. Gómez, E. Velasco, FC Rey Martínez, and A. Tejero González, (2010). The phenomenon of evaporative cooling from a humid surface as an alternative method for air-conditioning. Journal homepage: www. IJEE. IEE Foundation. org 1.1: 69-96. Kachhwaha, S. S. and Suhas Prabhakar, (2010). Heat and mass transfer study in a direct evaporative cooler. Journal of Scientific & Industrial Research 69: 705-710. Kloppers, Johannes C., and D. G. Kröger, (2005). A critical investigation into the heat and mass transfer analysis of counter-flow wet-cooling towers. International Journal of Heat and Mass Transfer 48.3: 765-777. Marletta, L. (2010). Air conditioning systems from a 2nd law perspective. Entropy, 12(4), pp: 859-877. Musa, Mu'azu, (2008). Novel evaporative cooling systems for building applications., Doctor al theses submitted to the University of Nottingham UK. Stoecker, Wilbert F., and Jerold W. Jones, 1958. Refrigeration and air conditioning. Vol. 3. London: McGraw-Hill. Taufiq, B. N., H. H. Masjuki, T. M. I. Mahlia, M. A. Amalina, M. S. Faizul, and R. Saidur, (2007). Exergy analysis of evaporative cooling for reducing energy 248 International Journal of Thermal Technologies, Vol.5, No.3 (Sept 2015)