RGM 75 B - C4P N Z Articulating Z Bracket for wire management

Similar documents
Rack Mount Series Installation Guide

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Series. Access Power Controllers. Installation Guide

Installation Guide for models:

Installation Guide for models:

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Power Supplies. Overview

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

SP-1000X. Panic Device Power Controller Installation Guide. Rev

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

AL600ULX Series. Power Supply/Charger. Installation Guide

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

more than just power! Altronix is the professional security industry s leading manufacturer

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

4100U City and Relay Cards Installation Instructions

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual

Model 17A00 Expansion Enclosure

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804

AL600ULADA. NAC Power Extender. Installation Guide

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

July 14, 1999 DF C-100.

631RF Amp Power Supply

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

Access Power Controllers with Power Supplies

AL800ULADA. NAC Power Extender. Installation Guide

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

CALL YOUR SALES CONSULTANT TODAY,

PDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual

TECHNICAL DATA OBSOLETE

June 10, 2002 DF C S2424

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

ECC-50/100C. Emergency Command Center

/ How To Order

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

Fire Control/Communicator

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

SAFEPATH Mass Notification System (SPMNS)

LifeAlarm Fire Alarm Controls

Specification/ Data Sheet

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

SLX Power. modular power system listed for all low voltage needs Access / Fire / Security / CCTV / Mass Notification

Installation, Operating and Maintenance Manual

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

Honeywell Power POWER TO RUN YOUR SYSTEM. Product Guide

Commercial and Light Industrial Fire Alarm Control Panel

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

MR-2602 Two Zone Fire Alarm Control Panel

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

Application, Installation, Operation & Maintenance Manual

Securitron. Switching Power Supplies

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

EHT/EHTD. Electromechanical Closer-Holder Release Devices

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Fratech Multipath-IP

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

PDD-FT-3. Fire Panel Interface With EOL Trigger. Installation and Specifications Manual

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Electric Release Panel Wiring Tips

PSN-1000 & PSN 1000(E) Installation Manual

Public Safety DAS Annunciator Panel

FireNET Plus Wiring Instructions

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

HCLASS Integrated Honeywell Power Systems

TrueAlert Addressable Notification Appliances

Power Supply Display Module PSDM. Installation and Operation Manual

DS7400Xi Addressable Control/ Communicator

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

2408/2900. Fire Guard

RELEASE DEVICE CONTROLS

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

Transcription:

GEMII RGM75 SERIES 4 Door 75W Integrated Mercury Drawer Standard / etworked, Single or Dual Voltage UL/CUL Unified Power Listing Four Post Mounting Overview Solving the industry problem of how to use the popular Mercury Security access control products in a 19 inch rack environment, the GEMII RGM Series is a UL listed rackmount system designed to provide both operating power and a mechanical housing for Mercury Security access control components. The unit is intended for mounting within a standard four post EIA 19 inch electronics rack with a maximum depth of 36 inches. RGM enclosures provide mounting for two Mercury and multiple LifeSafety Power FlexPower devices in an access control system capable of controlling four doors as a standalone or multiple doors when interconnected. The LSP equipment is provided as part of the RGM enclosure, Mercury equipment is provided by the integrator based on the job requirements. Available options include 120 or 230VAC input, single (12 or DC) or dual voltage operation (12 and DC), power distribution and control, individual output protection by either fuses or class 2 power limiting, buffered lock control, and remote reporting and test. Each LSP output is protected against electrical surges caused by lightning or transients on the external wiring (SurgeShield ) and each LSP control output is individually selectable for available DC voltages, and either failsafe or failsecure operation with fire alarm interface. etwork reporting capabilities include: operational fault status; power supply output; battery charging voltage; battery charging current, fire alarm input and status of each indivdual output. In addition to automated and scheduled status reports, diagnostic servicing and battery load tests can be performed remotely, saving or reducing the cost of on-site servicing. RGM Features UL Listed with Mercury controllers as a complete four door system Compartmentalized four door power architecture for maximum reliability Rack drawer slide assembly simplifies Mercury wiring and maintenance EP1502 status LED on front panel 120 or 230V AC user selectable input supports data center electrical systems Comprehensive wire management with tie down points & "Z" articulating arm etwork Monitoring and Reports Power supply operation and faults Battery run time, low battery, time to service Voltage and current of indivdula outputs with remote reset External room temperature Configuration Options /DC single or dual voltage options cover all access functions Power distribution for either direct (D8P) or buffered (C4P) lock control Individual output selection for failsafe, failsecure, lock voltage and fire alarm interface igh capacity battery charge capability Automotive fuses for ease of service and replaceability Easy expansion with multiple RGM models Available companion battery housing for rackmount use (part number: RBE) Fire Alarm Interface Latching or on-latching Remote reset capability ormally Open, ormally Closed Voltage or Polarity Reversal Activation Comprehensive fault detection and reporting May be connected into Mercury controllers or used standalone Form C contact transfer for AC Loss or brownout Form C contact transfer for abnormal system operation Lifetime Warranty GEMII RACKMOUT for MERCURY POWER (75 WATTS) SECODARY VOLTAGE RGM 75 B - C4P Z Articulating Z Bracket for wire management ETWORK OUTPUTS C4P - 4 controlled (ptc) C8-8 controlled (fused) D8P - 8 auxiliary (ptc) M8P - 8 managed (ptc) UIFIED POWER LISTED Internal Distribution Model o. etwork Voltage Current Bulk Auxiliary Control Managed RGM75-D8PZ 2 8 6A/ RGM75-C4PZ or or 2 4 3A/ RGM75-M8PZ Yes 2 8 RGM75B-D8PZ 2 8 RGM75B-C4PZ 2 4 2A/ RGM75B-C8D8PZ and and 8 8 2A/ RGM75B-M8PZ Yes 2 8 RGM75B-D8PM8PZ Yes 2 8 8 Single voltage - factory set to DC Dual voltage - outputs can be individually set for or DC etworking - monitors power supply, battery set and 8 relay control outputs *For CE 230VAC option, add " / E" suffix to model number, i.e RGM75-D8PZ / E September 2017 1/5 www.lifesafetypower.com

GEMII RGM75 SERIES - MERCURY RACKMOUT POWER SYSTEMS Specifications Input Power Input 120/230 VAC 50/60 z 83 Watts Thermal overload protection / Short circuit protection Output Power RGM75 75 Watts: 6 amps at 12 VDC or 3 amps at 24 VDC (factory default setting is DC) RGM75B 75 Watts: 2 amps at 12 VDC and 2 amps at 24 VDC (factory set to DC and DC) (allows 1A per Mercury board, 0.50A per lock. If Mercury board draws less, lock power is more) Internal Power D8/D8P eight auxiliary outputs: D8 fused at 3A/ea, D8P Class II Power limited at 2.5A/ea Distribution C4/C4P four control outputs: C4 fused at 3A/ea, C4P Class II Power limited at 2.5A/ea M8/M8P eight managed outputs: M8 fused at 3A/ea, M8P Class II Power limited at 2.5A/ea Individually selectable outputs on dual voltage systems Supervision AC input,, and output Low battery and battery presence supervision (form C contacts) AC fail supervision (form C contacts) System Fault, AC Fault, Ground Fault, Reverse Battery External Indicators AC on master on/off switch Front Panel Mercury Security Status LEDs Battery Charging Maximum charge current 1.0 amp Maximum battery capacity 40Ah Independent built-in charger for sealed lead acid or gel type batteries Microprocessor dual rate charging of 12 or 24 V battery sets Automatic switchover to standby battery when AC fails Zero voltage drop when switched over to battery backup Regulatory Compliance CE, UL294 6th Edition, UL603, UL1076, ULC S318, ULC S319 (can mix and match Mercury and LSP modules togethr in any combination) Access Panel Mounting Two slots for EP1502, EP2500, MR52 BTU Rating RGM75, RGM75B 33BTU/r Physical Dimensions 2U rack mount (19.00"W x 3.50" x 20.50"D) Weight 24 lbs. Z bracket wire management articulating arm Drawer layout example of 4 door dual voltage Drawer layout example of 4 door dual voltage managed system Four Door Integrated Standard RGM75B-C4PZ FPO75 - @ 2A lock power - @ 2A system power C4P - 4 Door lock control module Four Door Integrated etworked RGM75B-M8PZ FPO75 - @ 2A lock power - @ 2A system power ISCA - complete monitoring of PS, Mercury & Locks AC IPU T AC IPU T MR52 + - + - SYSTEM FPO75 POWER MR52 + - + - SYSTEM FPO75 POWER C4P L4 isca EP1502 EP1502 M8P September 2017 2/5 www.lifesafetypower.com

GEMII RGM75 SERIES - MERCURY RACKMOUT POWER SYSTEMS ITERAL POWER DISTRIBUTIO options D8 - DISTRIBUTED POWER TO MERCURY Eight individually protected power outputs D8P Class 2 power limited at 2.5A per output D8 Fused at 3A per output C4 - COTROL OUTPUTS FOR LOCKS 4 access control trip inputs 4 individually protected lock control outputs C4P Class 2 power limited at 2.5A per output C4 Fused at 3A per output Each input may be programmed to respond to: Application of voltage between 9 and 33VDC Removal of voltage between 9 and 33VDC ormally open dry contact transition ormally closed dry contact transition Each output may be programmed for the following modes: Voltage output from power supply one Voltage output from power supply two Fail-safe, Fail-secure Fire alarm over ride for egress lock control Fault Condition: Yellow fault LED FAULT DETECTIO AD REPORTIG DETECTED FAULT CODITIOS (ALL MODELS) AC Power AC loss, AC low, Master AC power switch DC Power and System Abnormal or loss of power supply operation Over current, over temperature condition DC output high, low Battery Presence, Earth Ground (user optional) Reversed battery condition, blown fuse or loss of output voltage on selected accessory boards (detected on the power supply) EXPASIO BATTERY BACK-UP 4, 8, 16 Doors Stack multiple Gemini rack mounts for higher door counts Add RBE battery enclosure for battery back up 4DR 4DR Battery backup 8 door battery back up RBE 6U M8 - MAAGED OUTPUTS FOR LOCKS & MERCURY 8 access control trip inputs 8 individually protected managed control outputs isca M8P Class 2 power limited at 2.5A per output M8 Fused at 3A per output Each input may be programmed to respond to: Application of voltage between 9 and 33VDC Removal of voltage between 9 and 33VDC ormally open dry contact transition ormally closed dry contact transition Activation or deactivation through software Each output may be programmed for the following modes: Voltage output from power supply one Voltage output from power supply two Fail-safe, Fail-secure Fire alarm over ride for egress lock control AC loss over ride for egress lock control Trigger points based on voltage or current values to send an alert via email or SMP Fault Condition: Yellow fault LED September 2017 3/5 www.lifesafetypower.com

L L V- I- I+ AC O FAI GD FLT AC FLT SYS FLT REV BAT GEMII RGM75 SERIES - MERCURY RACKMOUT POWER SYSTEMS Wire Management BACKPLATE COFIGURATIO OPTIOS Wire tie points Drawer tie down points for access wiring Back chassis tie down points secures wire bundle Articulating arm Z bracket with tie wrap points secures access wiring into drawer + DC 2 - + DC 1 - BAT FUSES 7.5A ATM FPO 75 Power Supply Style 2 C O DataLink FlexIO TYPE 1 EART GD DET AC IPUT 1 20/230 VAC C8P / M8P Z Bracket Wire Management Arm D8P C4P L4 AC IPU T EXPASIO BATTERY BACK-UP 8 Doors Stack multiple Gemini rack mounts for higher door counts Add RBE battery enclosure for battery back up 6U RBE Wire tie slots 8 Doors w/battery back up Mercury Status LED s September 2017 4/5 www.lifesafetypower.com

GEMII RGM75 SERIES - MERCURY RACKMOUT POWER SYSTEMS Mechanical 2U rack mount 19.00"W x 3.50" x 20.50"D Weight 27 lbs. GEMII - FROT o user serviceable parts inside, refer servicing to qualified service personnel 3.42" CTRLR AC POWER Cable Bracket Mount 2.96" ETLIK 15.87" GEMII- REAR CTRLR AC Power ETLIK 20.50" 3.18 19 20.50 36 Max Extension 16.95" lifesafetypower.com (888) 577-2898 info@lifesafetypower.com Optional Tamper Switch Part umber A05-311 Tamper and mounting bracket Specifications subject to change without notice. 2017 LifeSafety Power Inc. All rights reserved. LifeSafety Power and FlexPower are registered trademarks of LifeSafety Power Inc. Mercury Security is a registered trademark of Mercury Security. P01-722A 09/17 LifeSafety Power, Inc. 304 Terrace Drive Mundelein, IL 60060 September 2017 5/5 www.lifesafetypower.com